How To Test For An Architectural Test



Similar documents
ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania

PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

FM 4473 TEST REPORT. Rendered to: VTECH INDUSTRIES, LLP. SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight

AST M F /GSA TS01 T EST R EPO R T. Rendered to: UNI T E D ST A T ES A L U M INU M

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

PERFORMANCE TEST REPORT. Rendered to: TREMCO INCORPORATED. SERIES/MODEL: Proglaze ETA PRODUCT TYPE: Engineered Transition Assembly

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

TEST REPORT. Rendered to: INTERNATIONAL WINDOW Hayward, California. PRODUCT TYPE: Aluminum Hopper SERIES/MODEL: 7222

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

TEST REPORT. Report No.: B Rendered to: CROFT, LLC. Magnolia, Mississippi. PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

BLOWING DUST INFILTRATION TEST REPORT. Rendered to: TEX-STAR WINDOWS, INC. PROJECT: Blowing Dust Test SERIES: 3000 Horizontal Sliding Window

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

BLOWING DUST INFILTRATION TEST REPORT. Rendered to: TEX-STAR WINDOWS, INC. PROJECT: Blowing Dust Test SERIES: 3000 Double Hung Window

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

PERFORMANCE TEST REPORT. Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning)

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: T TYPE: Two-Lite Storefront

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MGM INDUSTRIES SERIES/MODEL: TYPE: Single Hung Window

TEST REPORT. Rendered to: DEXERDRY. For: Deck Weatherproofing System Installed with AZEK Deck Boards

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For:

TEST REPORT. Rendered to: INTEX MILLWORK SOLUTIONS, LLC. For: Rigid Cellular PVC Guardrail System Hampton RS40

TEST REPORT. Rendered to: LMT-Mercer Group, Inc. For: PRODUCT: 4" x 4" and 5" x 5" PVC Porch Posts with Aluminum Reinforcing

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: TREX COMPANY, LLC. Series/Model: Trex Seclusion

City of San Diego, CWP Guidelines

WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS:

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

PERFORMANCE TEST REPORT. Rendered to: FIBERLOCK TECHNOLOGIES, INC.

SECTION SERIES 1500 VINYL PATIO DOORS

Installation Detailed installation instructions are provided which should be strictly followed.

TEST REPORT. Rendered to: BRISTOLITE SKYLIGHTS Santa Ana, California

PERFORMANCE TEST REPORT. Rendered to: PROGRESSIVE FOAM TECHNOLOGIES, INC PRODUCT: EPS FOAM

Specifying Windows. Performance Standards

PERFORMANCE EVALUATION TEST REPORT. Rendered to: HANDI-SHIM, LLC. SERIES/MODEL: Handi-Shim 1/32", 1/16", 1/8" and 1/4" PRODUCT: Plastic Shims

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

Glossary. 1/3 1/3 1/3 - Configuration of a vent-fixed-vent (xox) window in which the vents and fixed panel are equal sizes

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR1 Teutonic Outswing Vinyl Entrance Door

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR2 Teutonic Outswing Vinyl Entrance Door

PERFORMANCE TEST REPORT

Series 3502 Thermal Series 3902 Fixed Thermal Architectural Grade Horizontal Sliding Window

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows

WINDOW PANNING AND TRIMS

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

Residential Garage Door Terminology

Assessing Curtain Walls

TEST REPORT. Rendered to: FAIRWAY BUILDING PRODUCTS, LP. For: LandMarke Railing System. PVC Guardrail System "Patent Number 7,487,941"

SECTION 6. Glass Storefront Doors:

Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

Garden Windows Builders Vinyl

Installation Instructions

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual

WHI TEST REPORT # FIRE RATED DOORS

Table of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide

PART 1 GENERAL 1.1 SECTION INCLUDES

Casement/Awning Window Parts Reference Catalog

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Wind Mitigation Inspection

Chapter 3 Pre-Installation, Foundations and Piers

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

Impact-Resistant Windows and Sliding Glass Doors

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: VL-WDW11 VistaLuxe Awning

STANDARD FOR NON-FIRE RATED ROLLING DOORS

Andersen Clad Inswing Entry Doors (2001 to Present)

Clad Direct Glaze Window Installation Instructions

CLEAR-DIVISIONS APERTO

Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...

RAM Industries 8600 Commerce Park Dr Houston, TX Tel: Fax:

REPORT NUMBER: COQ-003 ORIGINAL ISSUE DATE: July 19, 2013

DE Frame with C Series Sidelight

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots

Quality Building Products for over 50 Years

MANCHESTER SERIES(SGD-R35) SLIDING GLASS DOOR 5 5/8 FRAME DEPTH

CLEAR-DIVISIONS CENTERFOLD

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Window Glass Design 5 According to ASTM E 1300

Installation Window Building In Details

glass & Glazing Products

Total Building Commissioning: Case Study of the U.S. District Courthouse in Salt Lake City, Utah, USA

Window Installation Instructions

NanaWall SL73 - Thermally Broken Aluminum Framed Hurricane Rated Folding System with Miami Dade County, Florida NOA

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

Sun Windows General Information Sun New Construction Window Installation Instructions

Mark Cramer Inspection Services, Inc.

Evidence of Performance Resistance to wind load Watertightness Air permeability

T H E A A M A C E R T I F I C A T I O N P R O G R A M

SERIES 238 WINDOWS. NOTE: Read instructions completely before attempting any installation.

Important Information for Installer & Homeowner

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

Transcription:

Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: CORAL ARCHITECTURAL PRODUCTS SERIES/MODEL: PW 256 with Door Openings PRODUCT TYPE: Aluminum Impact Resistant Curtain Wall System Door Openings This report contains in its entirety: Cover Page: 1 page Report Body: 8 pages Test Equipment: 1 page Sketches: 2 pages Drawings: 16 pages Report No.: 85743.01-401-44 Test Dates: 12/17/08 Through: 06/10/09 Report Date: 12/07/09 Expiration Date: 06/10/13 2250 Massaro Blvd Tampa, FL 33619 phone: 813-628-4300 fax: 813-628-4433 www.archtest.com

Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: CORAL ARCHITECTURAL PRODUCTS 3010 Rice Mine Road Tuscaloosa, Alabama 35406 Report No.: 85743.01-401-44 Test Dates: 12/17/08 Through: 06/10/09 Report Date: 12/07/09 Expiration Date: 06/10/13 Project Summary: Architectural Testing, Inc. was contracted by Coral Architectural Products to perform testing on one Series/Model PW 256, aluminum impact resistant curtain wall system with door openings. The samples tested met the performance requirements set forth in the referenced test procedures for a ±3828 Pa (±80.0 psf) Design Pressure with missile impacts corresponding to Missile Level D and Wind Zone 4. Test specimen description and results are reported herein. The samples were provided by the client. Test Procedures: The test specimens were evaluated in accordance with the following: ASTM E 1886-05, Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials. ASTM E 1996-05, Standard Specification for Performance of Exterior Windows, Glazed Curtain Walls, Doors and Storm Shutters Impacted by Wind Borne Debris in Hurricanes. Test Specimen Description: Series/Model: PW 256 with Door Openings Product Type: Aluminum Impact Resistant Curtain Wall System with Entrance Door Overall Size: 3531 mm (139") wide by 3810 mm (150") high Door Leaf Size (2): 908 mm (35-3/4") wide by 2419 mm (95-1/4") high Door Leaf Daylight Opening Size (2): 667 mm (26-1/4") wide by 2076 mm (81-3/4") high 2250 Massaro Blvd Tampa, FL 33619 phone: 813-628-4300 fax: 813-628-4433 www.archtest.com

Architectural Testing 85743.01-401-44 Page 2 of 8 Test Specimen Description: (Continued) Fixed Daylight Opening Above Door Size: (47-1/4") high 1880 mm (74") wide by 1200 mm Top Right Fixed Daylight Opening Size: 1461 mm (57-1/2") wide by 1200 mm (47-1/4") high Lower Right Fixed Daylight Opening Size: (94-3/4") high 1461 mm (57-1/2") wide by 2407 mm Finish: All aluminum was mill finished. Glazing Details: The fixed lites utilized a 9/16" thick glazing fabricated from two sheets of 1/4" heat strengthened glass separated by 0.075" Vanceva interlayer. The lites were exterior glazed onto a Dow 995 silicone bedding and secured in place with aluminum pressure plates. The fixed lites of glass utilized a 3/4" glazing bite. Aluminum mull caps were added to the exterior. Weatherstripping: Description Quantity Location 0.270" backed by 1/4" 1 Row Perimeter of the door frame stop hollow vinyl bulb gasket 0.115" by 7/16" kerf-mounted 2 Rows Length of the active door leaf woven weatherstrip Frame Construction: The frame was constructed of extruded aluminum. The corners were coped, butted, sealed and secured with three #14 x 1" hex head screws located through the jambs into the head and sill screw boss. Door Panel: Door panel Series 381 was only utilized as a filler for the frame. A 2" x 2" x 1/4" by 2' long aluminum angle was utilized at the top and bottom of the door frame to secure the doors in place to the frame and threshold.

Architectural Testing 85743.01-401-44 Page 3 of 8 Test Specimen Description: (Continued) Screen Construction: No screen was utilized. Hardware: No hardware was utilized. Drainage: No drainage was utilized. Reinforcement: The intermediate vertical mullion utilized a full-height 4-1/2" x 1-7/8" x 1/4" steel "C" channel with a 3-3/4" wide by 3/4" thick flat bar welded to the "C" channel. It was secured with #8 x 3" bolts through the aluminum mullion located 1" from head, sill and horizontal mullion. Installation: The system was secured to an 8" steel "C" channel. The door to jamb was secured to the channel with 1/2"-13 x 4-1/2" bolts located 2-1/2", 45-1/2", 50-1/2", 67-1/2" and 98-1/2" from the bottom. The head utilized 1/2"-13 x 2" bolts 6" from each end and 4" each side of the vertical mullion. The sill utilized two 1/2"-13 x 2" bolts located 6" from the jamb and 6" from the vertical mullion.

Architectural Testing 85743.01-401-44 Page 4 of 8 Test Results: The following results have been recorded: ASTM E 1886, Large Missile Impact Conditioning Temperature: 26.6 C (80 F) Missile Weight: 3433.8 g (9.2 lbs) Missile Length: 2.4 m (8' 0") Muzzle Distance from Test Specimen: 5.18 m (17' 0") Test Unit #1 Impact #1: Missile Velocity: 15.4 m/s (50.4 fps); orientation within ±5 of vertical Impact Area: Center of the vertical mullion Observations: Missile hit target area, dented the aluminum mullion cap with no other damage. Results: Pass Impact #2: Missile Velocity: 15.5 m/s (50.8 fps); orientation within ±5 of vertical Impact Area: Center of the horizontal mullion above the double door assembly. Observations: Missile hit target area, dented the aluminum mullion cap and fractured the fixed lite above, with no other damage. Results: Pass Note: See Architectural Testing Sketch #1 for impact locations.

Architectural Testing 85743.01-401-44 Page 5 of 8 Test Results: (Continued) ASTM E 1886, Air Pressure Cycling Test Unit #1 Design Pressure: ±3828 Pa (±80.0 psf) Pressure Range Pa (psf) 766 to 1914 (16 to 40) 0 to 2297 (0 to 48) 1914 to 3062 (40 to 64) 1149 to 3828 (24 to 80) Pressure Range Pa (psf) 1149 to 3828 (24 to 80) 1914 to 3062 (40 to 64) 0 to 2297 (0 to 48) 766 to 1914 (16 to 40) Number of Cycles 3500 3.00 300 5.64 600 2.87 100 5.49 POSITIVE PRESSURE Average Maximum Deflection at Indicator mm (inch) Cycle Time (seconds) #1 #2 #3 #4 #5 #6 4.82 (0.19) 5.84 (0.23) 6.86 (0.27) 8.13 (0.32) 3.30 (0.13) 14.99 (0.59) 16.51 (0.65) 20.07 (0.79) 24.38 (0.96) 6.60 (0.26) 14.48 (0.57) 18.03 (0.71) 21.84 (0.86) 26.16 (1.03) 7.87 (0.31) 9.14 (0.36) 10.67 (0.42) 12.95 (0.51) Permanent Set 8.13 7.11 (0.32) (0.28) 15.24 (0.60) 18.80 (0.74) 22.10 (0.87) 26.42 (1.04) 8.13 (0.32) 8.63 (0.34) 9.40 (0.37) 10.67 (0.42) 11.94 (0.47) 9.40 (0.37) NEGATIVE PRESSURE Average Number of Maximum Deflection at Indicator mm (inch) Cycle Time Cycles (seconds) #1 #2 #3 #4 #5 #6 50 7.76 25.15 18.80 5.08 9.65 24.89 9.65 (0.99) (0.74) (0.20) (0.38) (0.98) (0.38) 1050 3.74 21.08 15.75 4.57 7.87 21.08 9.40 (0.83) (0.62) (0.18) (0.31) (0.83) (0.37) 50 5.63 12.45 8.89 2.29 4.32 12.19 2.29 (0.49) (0.35) (0.09) (0.17) (0.48) (0.09) 3350 3.66 8.64 5.84 1.27 2.29 7.87 1.52 (0.34) (0.23) (0.05) (0.09) (0.31) (0.06) Permanent Set 2.54 1.02 0.25 1.02 2.03 0.51 (0.10) (0.04) (0.01) (0.04) (0.08) (0.02) Observations: No additional damage was observed. Result: Pass Note: See Architectural Testing Sketch #2 for indicator locations.

Architectural Testing 85743.01-401-44 Page 6 of 8 General Note: Upon completion of testing, the specimens met the requirements of Section 7 of ASTM E 1996. Test Equipment: (See Appendix A) Cannon: Constructed from steel piping utilizing compressed air to propel the missile Missile: 2x4 Southern Pine Timing Device: Electronic Beam Type Cycling Mechanism: Computer controlled centrifugal blower with electronic pressure measuring device Deflection Measuring Device: Linear transducers Tape and film were used to seal against air leakage during structural testing. In our opinion, the tape and film did not influence the results of the test. Drawing Reference: The test specimen drawings have been reviewed by Architectural Testing and are representative of the test specimen reported herein. List of Official Observers: Name William Smith Sr. William Smith Jr. Jack Hook Scott Parker Don Beltz John McClane Company Impact Glazing Consultants Impact Glazing Consultants Architectural Testing, Inc. Architectural Testing, Inc. Architectural Testing, Inc. Architectural Testing, Inc.

Architectural Testing 85743.01-401-44 Page 7 of 8 Detailed drawings, data sheets, representative samples of test specimens, a copy of this report, or other pertinent project documentation will be retained by Architectural Testing, Inc. for a period of four years from the original test date. At the end of this retention period, such materials shall be discarded without notice and the service life of this report will expire. Results obtained are tested values and were secured by using the designated test methods. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. This report may not be reproduced, except in full, without the written approval of Architectural Testing, Inc. For ARCHITECTURAL TESTING, INC. John C. McClane Laboratory Manager Joseph A. Reed, P.E. Director - Engineering and Product Testing JCM:ck/cmd Attachments (pages): This report is complete only when all attachments listed are included. Appendix-A: Test Equipment (1) Appendix-B: Sketches (2) Appendix-C: Drawings (16)

Architectural Testing 85743.01-401-44 Page 8 of 8 Revision Log Rev. # Date Page(s) Revision(s) 0 12/07/09 N/A Original report issue This report produced from controlled document template ATI 00165, revised 03/05/09.

Architectural Testing 85743.01-401-44 Appendix A Test Equipment Instrument Manufacturer Asset # Transducer Celesco 004284 Transducer Celesco 005428 Transducer Celesco 004280 Transducer Celesco 004285 Transducer Celesco 005427 Transducer Celesco 004282 Control panel Architectural Testing, Inc. 004821 Cannon Architectural Testing Inc. 004273 Temperature/ Barometer Davis Instrument 004330

Architectural Testing 85743.01-401-44 Appendix B Sketches

Architectural Testing 85743.01-401-44 Appendix C Drawings