Busch-Dimmer. Busch Universal Master Dimmer Insert 6593 U-500 Power electronic module 6594 U-500 1473-1-7871 29.03.2012

Similar documents
, , 0218/11-101, 0218/ UAE socket Cat. 5e, Cat. 6 A iso

Operating Instructions Busch-Wächter AGM- 110 MasterLINE Rev

ABB-Welcome M2304. Video distributor VER:

ABB-Welcome M2302. Gateway VER:

Operating Instructions Busch-Dimmer. Universal master dimmer 2251 UCGL Rev

ABB-Welcome M M M Audio handset indoor station VER:

Pos: 2 /#Neustruktur#/Online-Dokumentation (+KNX)/Titelblätter/AudioVideo/Titelblatt @ 1

ABB-Welcome M2300. System controller VER:

Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI

DALI RC BASIC SO. Control unit Operating instructions

KNX Technical Reference Manual ABB i-bus KNX. ETS-App "KNX Bus Update"

How To Use The Knx (Knx) On A Computer Or Tablet Or Ipad Or Ipa Or Ipam (Auntor) On Your Computer Or Ipan (Aplo) On An

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

HERZ-Thermal Actuators

Operating instructions IV / 2007

Transmitter Actuator 230V wave UP 560. Operation

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

MOUNTING AND OPERATING INSTRUCTIONS

15 Series - Electronic step relay and dimmer. Features SERIE

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Busch-Watchdog Presence EIB Type:

Product and functional description

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Basics of Dimming. ISC Learning Centre

Operating instructions II / 2004

Infrarot-Bewegungsmelder IP44

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

Remote Monitoring and REC 501 Control Unit Product Guide

Product and Application Description

E-STOP relays, safety gate monitors

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

TIG INVERTER INSTRUCTION MANUAL

DKG 972 Gas Burner Safety Control

Operating instructions. RCD flat 4-fold, 6-fold

Safety automation solutions

Advanced User s Guide

basicdim DGC Compact control module

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Installation Guide. DEVIreg 530. Electronic Thermostat.

Conventional Fire Detection and Extinguishant Control System Specification

Electronic Power Control

Electronic Pressure Switch EDS 3000

Automatic start of a generator

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

DVI 980/982 (Honeywell Nr. S4865) Gas Burner Safety Control

Operation Manual. Trash Water Pump - ARTIKEL Read and follow the operating instructions and safety information before using for the first time.

Three-phase monitoring relay CM-PFE

Antenna Splitter ASA 1. Instruction manual

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Thermistor motor protection

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Quick Connect. quick - simple - efficient.

Niko Home Control. Installation Manual

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Operating Instructions Thermo Call TC3. General Information. Use. Dear Webasto customer,

Safety technique. Emergency stop module BO 5988 safemaster

User Manual THR840DUK Digital Thermostat

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB-Welcome 83325/2-5..

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP )

Descriptive Technical Documentation. DTD no

Operating Instructions. Room temperature controller

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Electronic overload relay EF19 and EF45

Electronic Pressure Switch EDS 300

Operating Instructions

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Guide to Starters Guide to Starters Page 1 of 17

UM-X Field display for continous level sensors

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Inwall 4 Input / 4 Output Module

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Tracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL

For installation guide see reverse of book

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

R.C.C.B. s two-pole LEXIC

aseries A13B Mini Bullet Camera User Manual

EasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Manual for Fire Suppression & Methane Detection System

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Installation and User Guide

Installation and operating instructions. Solar charge controller Solarix MPPT Z Z

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

Transcription:

Pos: 2 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Titelblätter/Dimmer/Titelblatt - 6593 / 6594 U-101 -- ABB @ 23\mod_1333091750290_15.docx @ 207088 @ @ 1 === Ende der Liste für Textmarke Cover === 1473-1-7871 29.03.2012 Busch Universal Master Dimmer Insert 6593 U-500 Power electronic module 6594 U-500

Pos: 4 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Inhaltsverzeichnis (--> Für alle Dokumente <--)/Inhaltsverzeichnis @ 19\mod_1320649044386_15.docx @ 109653 @ @ 1 === Ende der Liste für Textmarke TOC === 1 Safety... 3 2 Environment... 3 2.1 Disposal... 3 3 Technical data... 4 4 Reduction of the connection load (derating)... 5 5 Function... 6 5.1 Load types... 6 5.2 Possible combinations... 7 5.3 Universal master dimmer function... 8 5.4 Operation mode... 8 5.5 Capacity boosting... 8 5.6 Protective functions... 8 6 Connection... 9 7 Mounting / Installation... 11 7.1 Requirements for the electrician... 11 7.2 Mounting... 12 7.3 Mains and load connection... 12 7.4 Monting in connection with other devices... 12 7.4.1 Mounting in connection with an IR control element (remote control)... 12 7.5 Mounting with Busch Watchdog Flush-Mounted Sensors... 12 7.6 Auxiliary posts... 12 8 Commissioning... 13 8.1 Universal master dimmer function... 13 8.2 Overload... 13 8.3 Short-circuit... 13 9 Operation... 14 9.1 Operation with the pushbutton control element (pushbutton operation)... 14 9.1.1 Switching ON... 14 9.1.2 Activation with dark start function... 14 9.1.3 Dimming... 14 9.1.4 Switching OFF... 14 9.1.5 Special functions... 14 9.2 Operation with Busch Watchdog Flush-Mounted Sensors... 15 9.2.1 Type designation in the Busch Watchdog programme... 15 9.2.2 Auxiliary post operation... 15 9.2.2.1 Passive auxiliary post operation by means of NO contact button... 15 9.2.2.2 Active auxiliary post operation (Busch Watchdog) with 6805U... and flush-mounted sensors... 15 9.3 Operation with the Busch Watchdog Presence 6813(-183)-101..., 6813/11-24..., 6813/11-183...... 15 9.4 Operation with timer control element 6455... 15 1473-1-7871 2

Pos: 7 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Sicherheit (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ @ 1 Pos: 9 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Umwelt (--> Für alle Dokumente <--)/Hinweise/Hinweis - Umwelt - Hinweis Elektrogeräte @ 18\mod_1302763973434_15.docx @ 103500 @ @ 1 Pos: 12 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 Safety Pos: 6 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_1302612791790_15.docx @ 103357 @ 1 @ 1 1 Safety Warning E lectric voltage! Risk of death and fire due to electrical voltage of 230 V. Work on the 230V supply system may only be performed by authorised electricians! Disconnect the mains power supply prior to installation and/or disassembly! Pos: 8 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/U - Z/Umwelt @ 18\mod_1302614158967_15.docx @ 103383 @ 1 @ 1 2 Environment Consider the protection of the environment! Used electric and electronic devices must not be disposed of with domestic waste. The device contains valuable raw materials which can be recycled. Therefore, dispose of the device at the appropriate collecting depot. Pos: 10 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/2. Ebene/A - F/Entsorgung @ 20\mod_1325760636580_15.docx @ 136573 @ 2 @ 1 2.1 Dis pos al Pos: 11 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Umwelt (--> Für alle Dokumente <--)/Hinweise/Hinweis - Umwelt - Entsorgung Elektrogeräte @ 20\mod_1325760695972_15.docx @ 136583 @ @ 1 All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies. The products meet the legal requirements, in particular the laws governing electronic and electrical devices and the REACH ordinance. (EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS) (EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006) 1473-1-7871 3

Pos: 14 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Technische Daten/Dimmer/Technische Daten - 6593 U / 6594 U @ 23\mod_1333093163796_15.docx @ 207102 @ @ 1 Pos: 15 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 Technical data Pos: 13 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Technische Daten @ 11\mod_1279185386320_15.docx @ 83019 @ 1 @ 1 3 Technical data General Capacity booster Max. 1 power electronic module 6594 U... Pushbutton input: 230 V ~ ±10%, 50 / 60 Hz Max. pushbutton line length: 100 m Max. total cable length between the Max. 30 cm from device to device control outputs (S-S, G-G): Protection type: IP 20 Ambient temperature range: 0 +35 C (see Fig. 1) Device-s pecific Nominal voltage: 6593U...: 230 V ~ ±10%, 50 Hz 6594U...: 230 V ~ ±10%, 50 Hz Nominal current: 6593U...: 1.83 A (universal master dimmer) 6594U...: 1.37 A (power electronic module) Nominal power: 6593U...: 420 W/VA (dependent on ambient temperature (see 6594U...: 315 W/VA Fig. 1)) Minimum load: 6593U...: 60 W/VA 6594U...: 200 W/VA 1473-1-7871 4

Pos: 18 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Derating (--> Für alle Dokumente <--)/Derating - Berechnung Nennleistung eleltronische-konventionelle Trafos @ 20\mod_1327415459238_15.docx @ 137113 @ @ 1 Pos: 19 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Derating (--> Für alle Dokumente <--)/Derating - Kurve 01 -- 35-70 -- Kurve @ 19\mod_1311948779960_15.docx @ 108276 @ @ 1 Pos: 20 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 Reduction of the connection load (derating) Pos: 16 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Derating @ 19\mod_1311253981718_15.docx @ 107963 @ 1 @ 1 4 Reduction of the connection load (derating) Pos: 17 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Derating (--> Für alle Dokumente <--)/Derating - Leistungsminderung 20 prozent @ 20\mod_1327310948240_15.docx @ 137093 @ @ 1 The dimmer heats up during operation because part of the connected load is lost and converted into heat. The specified rated power is designed for dimmer installation in a solid masonry wall. When installing the dimmer in a wall made of gas concrete, wood, or plasterboard, the maximum connection load must be reduced by 20%. The connected load must always be reduced when several dimmers are installed one below the other or when other heat sources cause additional heating. In intensely heated-up rooms, the maximum connected load must be reduced according to the diagram. Use the following formula for the calculation of the nominal power: Nominal power = transformer losses* + lamp power * 5% of the nominal transformer power in the case of electronic transformers * 20% of the nominal transformer power in the case of conventional transformers Fig. 1: Derating Unit Meaning % Nominal power C Ambient temperature 1473-1-7871 5

Pos: 23 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Lastarten (--> Für alle Dokumente <--)/Lastarten 02 @ 20\mod_1326269868830_15.docx @ 136915 @ @ 1 Pos: 24 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 Function Pos: 21 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Funktion @ 18\mod_1308560693057_15.docx @ 106869 @ 1 @ 1 5 Function Pos: 22 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/2. Ebene/G - L/Lastarten @ 20\mod_1326269704379_15.docx @ 136905 @ 2 @ 1 5.1 L oad types Load types: 230 V incandescent lamps 230 V halogen lamps Low-volt halogen lamps with conventional transformers Low-volt halogen lamps with electronic transformers Note Conventional and electronic transformers must not be dimmed together. A mixed load of resistive and inductive, but also of resistive and capacitive consumers is possible. 1473-1-7871 6

Pos: 26 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Kombinationsmöglichkeiten/Dimmer/Kombinationsmöglichkeiten - 6593 U / 6594 U @ 23\mod_1333093514932_15.docx @ 207117 @ @ 1 Function Pos: 25 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/2. Ebene/G - L/Kombinationsmöglichkeiten @ 19\mod_1320312769153_15.docx @ 109520 @ 2 @ 1 5.2 Pos s ible combinations 6593 U... X 6455... X 6813/11-xxx... X 6813-xxx-101... X 6800-xxx-104(M)... X 6810-21x... X 6066-xxx-xxx... X 6543-xxx-10x... The dimmer can be controlled using additional control elements through the button auxiliary post input. Pos: 27 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 1473-1-7871 7

Pos: 29 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 Function Pos: 28 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Funktion/Dimmer/Funktionen - 6593 U / 6594 U @ 19\mod_1311252759366_15.docx @ 107947 @ 2222 @ 1 5.3 Universal master dimmer function The device provides the following functions: Phase-angle/phase-section (load-dependent) Operation mode selection via handwheel Dark start function 5.4 Operation mode The following operation modes can be selected using the handwheel: 1 Memory function on, soft on/off inactive (basic function) 2 Memory function on, soft on/off active* 3 Memory function off, soft on/off active* 4 Memory function on, soft on inactive, soft off active 5 Memory function on, soft on active, soft off inactive* * Not in connection with Busch Watchdog sensors Fig. 2: Handwheel Memory function: The current brightness value is saved as a memory value at deactivation. The dimmer switches on with this value the next time it is activated. Soft OFF: The dimmer decreases slowly from the set brightness to the minimum brightness and then switches OFF. Soft ON: Starting at the minimum brightness, the dimmer switches on and increases slow to the set brightness value. 5.5 Capacity boos ting Capacity is boosted via a power electronic module 6594U. 5.6 Protective functions The device provides the following protective functions: Inrush current limitation through soft start Electronic overload/overtemperature protection Electronic short-circuit protection Thermal fuse 1473-1-7871 8

Pos: 31 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Anschluss/Dimmer/Anschluss - 6593 U / 6594 U @ 23\mod_1333094417158_15.docx @ 207147 @ @ 1 Connection Pos: 30 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Anschluss @ 19\mod_1309248278435_15.docx @ 107413 @ 1 @ 1 6 Connection Caution If illuminated pushbuttons are used, only pushbuttons with a separate N-connection are allowed. Contact-parallel illumination is not permitted. Note on radio interference suppression The dimmer contains electronic interference suppression and is thus "low-noise." The S and G data lines are to be seen as internal connecting lines and should be laid over as short a distance as possible (see the "Technical data" chapter on page 4). 6593U... Fig. 3: Busch universal master dimmer with pushbutton operation The N-connection is required only in special cases (e.g., noise development when the connected electronic transformer is switched off! It has no influence on noises of the connected transformer when it is on). 6593U... 6594U... Fig. 4: Capacity booster of the universal master dimmer with power electronic module, pushbutton operation. During operation with power electronic module 6594U..., the controlled outputs must be connected to guarantee all protective functions of the dimmer system. 1473-1-7871 9

Pos: 32 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 Connection 6805U... 6593U... Fig. 5: Dimmer 6593U... with Busch Watchdog auxiliary post 6805U... and NO contact button auxiliary post In pushbutton mode, the phase of the extension unit and the phase of the supply voltage must be the same. With pushbutton extensions, the lighting glow lamp should not be connected with parallel contacts (use pushbutton with N connection). When laying lines, ensure that there is sufficient space between the control and load lines (5 cm minimum). The maximum line length of the pushbutton auxiliary post is 100 m. Changing the line routing of existing two-way circuits and intermediate switch circuits is not necessary. Note regarding conventional transformers During the operation of conventional transformers, each transformer must be fuse-protected on the primary side according to manufacturer's specifications. Only safety transformers according to DIN EN 61558 should be used. Switching the load through a serial switch contact is not permissible since overcurrents and overvoltages can occur at reactivation, which could possibly lead to a destruction of the dimmer. The secondary-side idling of conventional transformers is permitted neither during commissioning nor during operation. Operate conventional transformers always at the nominal transformer load. To achieve the same brightness level of the halogen lamps over the entire adjusting range from bright to dark, transformers with the same secondary voltage and the same power should be used. 1473-1-7871 10

Pos: 34 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Sicherheit (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Niederspannungs- und 230 V-Leitungen @ 18\mod_1302617821491_15.docx @ 103465 @ @ 1 Pos: 36 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 Mounting / Installation Pos: 33 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/M - O/Montage / Installation @ 18\mod_1302613966111_15.docx @ 103373 @ 1 @ 1 7 Mounting / Installation Warning E lectric voltage! Risk of death and fire due to electrical voltage of 230 V. Low-voltage and 230 V cables must not be installed together in a flush-mounted socket! In case of a short-circuit there is the danger of a 230 V load on the low-voltage line. Pos: 35 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Sicherheit (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Fachkenntnisse @ 18\mod_1302774384017_15.docx @ 103564 @ 2 @ 1 7.1 R equirements for the electrician Warning E lectric voltage! Install the device only if you have the necessary electrical engineering knowledge and experience. Incorrect installation endangers your life and that of the user of the electrical system. Incorrect installation can cause serious damage to property, e.g. due to fire. The minimum necessary expert knowledge and requirements for the installation are as follows: Apply the "five safety rules" (DIN VDE 0105, EN 50110): 1. Disconnect from power; 2. Secure against being re-connected; 3. Ensure there is no voltage; 4. Connect to earth; 5. Cover or barricade adjacent live parts. Use suitable personal protective clothing. Use only suitable tools and measuring devices. Check the type supply network (TN system, IT system, TT system) to secure the following power supply conditions (classic connection to ground, protective earthing, necessary additional measures, etc.). 1473-1-7871 11

Pos: 40 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 Mounting / Installation Pos: 37 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.docx @ 103424 @ 2 @ 1 7.2 Mounting Pos: 38 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Montage/alle Geräte/Montage - UP-Dosen - DIN 49073-1 oder geeignetes Aufputzgehaeuse - Ohne Docvariable @ 20\mod_1325766034453_15.docx @ 136593 @ @ 1 The device may only be installed in suitable flush-mounted sockets (DIN 49073-1) or a suitable surface-mounted housing. Pos: 39 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Montage/Dimmer/Montage - 6593 U / 6594 U @ 23\mod_1333095068818_15.docx @ 207162 @ 22322 @ 1 7.3 Mains and load connection The mains connection takes place at terminals L and N. The load is connected to the terminals (controlled outputs). Connection to terminal N is an option and serves for reducing the noise on the transformer load when switched off. 7.4 Monting in connection with other devices 7.4.1 Mounting in connection with an IR control element (remote control) In combination with the IR control element 6066..., the mounting site should lie within the specified values for the IR receiving range. Please note that the IR receiving range may vary due to extraneous light (e.g., sunlight, illumination). Attachment of the control element: In the case of the IR control element 6066..., set the desired address first. Put the control element on the dimmer. Make sure that the IR control element does not jam in the frame. Removal of the control element: Use the provided left and right notches for leverage. 7.5 Mounting with B usch Watchdog Flush-Mounted S ensors The dimmer can be operated with the Busch Watchdog 180 Flush-Mounted Sensors 6810..., 6800-104(M)... or higher; in the process, a switching function (ON/FF) is possible - but no dimming function! The mounting height depends on the selection of the flush-mounted sensor. Further information on mounting height, the adjustment of the flush-mounted sensors, and so on can be found in the pertinent operating instructions of the respective flush-mounted sensor. 7.6 Auxiliary pos ts Any number of pushbuttons (e.g., 2020...) can be connected in parallel for switching and dimming via the Terminal 1 pushbutton input. Sensing is performed to the left (L). 1473-1-7871 12

Pos: 43 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 Commissioning Pos: 41 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/G - L/Inbetriebnahme @ 11\mod_1279185496977_15.docx @ 83035 @ 1 @ 1 8 Commissioning Pos: 42 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Inbetriebnahme/Dimmer/Inbetriebnahme - 6593 U / 6594 U @ 19\mod_1311257293574_15.docx @ 107995 @ 222 @ 1 8.1 Universal master dimmer function Upon connection of the supply voltage, the microprocessor integrated in the dimmer evaluates the characteristics of the connected service load and decides whether phase-angle or phase-section control is to be employed. During this calibration process, the lighting installation switches on for up to 2 seconds. Notes To guarantee precise load detection by the dimmer, it must not be operated with a short circuit or with secondarily idling, conventional transformers when the mains voltage is additionally switched on. Universal master dimmers and power electronic modules heat up during operation because part of the connection load is lost and converted into heat. If the ambient temperature rises above 35 C during operation, the connection load must be reduced according to the diagram; see Fig. 1 on page 5. At an ambient temperature of 50 C, the allowed power is reduced to 57%, at 60 C to 28%. 8.2 Overload When activating the electronic overload protection (overload or overtemperature due to incorrect installation or insufficient cooling), the set brightness of the lighting system is reduced. When overload/overtemperature lasts for more than 10 minutes, the dimmer will switch itself off. The mains voltage must be switched off to remedy faults. The load of the dimmer must be checked and reduced if pertinent. Once the overload is eliminated and after a subsequent cool-down phase, the dimmer is again ready for operation. 8.3 S hort-circuit In case of a brief short-circuit of the load, the dimmer disconnects the connected loads and re-connects them afterwards. In case of a permanent short-circuit, the dimmer switches off completely. The mains voltage must be switched off to remedy faults. After the short-circuit has been rectified, the dimmer is ready for operation. 1473-1-7871 13

Pos: 45 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Bedienung/Dimmer/Bedienung - 6593 U / 6594 U @ 23\mod_1333095443607_15.docx @ 207177 @ 2333332334422 @ 1 Operation Pos: 44 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bedienung @ 11\mod_1279185541649_15.docx @ 83043 @ 1 @ 1 9 Operation 9.1 Operation with the pushbutton control element (pus hbutton operation) 9.1.1 S witching ON Briefly press the pushbutton auxiliary post. 9.1.2 Ac tivation with dark s tart function Keep the pushbutton auxiliary post pressed. The dimmer starts with the basic brightness and becomes "brighter" as long as the pushbutton is pressed. 9.1.3 Dimming Keep the pushbutton auxiliary post pressed. The dimmer changes the brightness of the connected lighting system. With every stop, the dimming direction is reversed. At maximum brightness, the dimmer stops; at minimum brightness, the dimming direction changes. 9.1.4 S witching OFF Briefly press the control element/pushbutton auxiliary post. 9.1.5 S pecial functions Switching OFF with soft OFF function (handwheel position 4): Briefly press the control element/pushbutton auxiliary post. The current brightness value is saved as a memory value. The dimmer decreases slowly from the set brightness to the minimum brightness and then switches OFF. Or Switching ON with soft ON function (handwheel position 5): Briefly press the control element/pushbutton auxiliary post. The saved brightness value (memory) is changed starting with the minimum brightness. 1473-1-7871 14

Operation 9.2 Operation with B usch Watchdog Flush-Mounted S ensors 9.2.1 Type designation in the B usch Watchdog programme These operating instructions describe both the Busch Watchdog (Art. No. 6810...) and the comfort sensors (Art. No. 6800-104(M)...) as "flush-mounted sensors." Please pay attention to the correct type assignment in the description. The type designation can be found on the back side of the respective device. After the interruption of the mains voltage or mains connection, the dimmer switches the connected consumers - independent of the brightness set on the sensor on for 80 seconds when flush-mounted sensors 6810... are used on for the selected duration (at least one minute at time settings < 1 minute) when flush-mounted sensors 6800-104(M)... are used (exception: short-time pulse ). Note The soft OFF function is possible to the full extent from version -104(M)... 9.2.2 Auxiliary pos t operation In connection with flush-mounted sensors, auxiliary post operation is possible via activation by NO contact button or auxiliary post insert 6805U... 9.2.2.1 Passive auxiliary post operation by means of NO contact button The function performed on the NO contact pushbutton causes the connected consumers to be switched independent of the measured brightness for about 80 seconds when flush-mounted sensors 6810... are used for the time set on the flush-mounted sensor when flush-mounted sensors 6800-104(M)... are used Note Deactivation/dimming is not possible through the auxiliary post. Multiple activation when the illumination is switched on leads to a "reset" of the previously expired time. 9.2.2.2 Active auxiliary pos t operation (B us ch Watchdog) with 6805U... and flus h-mounted sensors Since the main unit and auxiliary post each have a separate dusk value setting the current brightness conditions at the mounting position can be taken into consideration individually. The actual switch-off delay results when adding the time set on the main unit and on the auxiliary post. In connection with the flush-mounted sensors 6800--104(M)..., it is recommended to operate the auxiliary posts with the "short-time pulse" time setting if the times set on the main unit can be observed as precisely as possible. Note Further information on mounting height can be found in the pertinent operating instructions of the respective flush-mounted sensor. 9.3 Operation with the B usch Watchdog Pres ence 6813(-183)-101..., 6813/11-24..., 6813/11-183... Detailed information can be found in the pertinent operating instructions of the presence detector. 9.4 Operation with timer control element 6455... Detailed information can be found in the pertinent operating instructions of the control element. === Ende der Liste für Textmarke Content === 1473-1-7871 15

=== Ende der Liste für Textmarke Backcover === Pos: 47 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Rückseiten (--> Für alle Dokumente <--)/Rückseite - Busch-Jaeger - Allgemein @ 20\mod_1327320074886_15.docx @ 137103 @ @ 1 A member of the ABB Group Busch-Jaeger Elektro GmbH PO box 58505 Lüdenscheid Freisenbergstraße 2 58513 Lüdenscheid Germany Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document. We reserve all rights to this document and the topics and illustrations contained therein. The document and its contents, or extracts thereof, must not be reproduced, transmitted or reused by third parties without prior written consent by ABB. 1473-1-7871 29.03.2012 www.busch-jaeger.com info.bje@de.abb.com Copyright 2012 Busch-Jaeger Elektro GmbH All rights reserved Central sales service: Phone: +49 (0) 180 5 669900 Fax: +49 (0) 180 5 669909