1 Descriptive Technical Documentation - Model-dependent - DTD no Model(s): PT 7135 C, PT 7136, PT 5135 C, PT , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
2 This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
3 DTD no Contents General Information A B C D Warning and Safety Instructions Modification History Technical Data Layout of Electrical Components Function Groups 020 Door 2 Function Door lock (A2) Drum, bearing, sensors, heater bank 1 Technical Data Function Heating control (R1, R2, R3) Temperature limiter (F2) NTC temperature sensor - Fill ring (1R30) NTC temperature sensor - Heater bank (2R30) Light - Drum (H3/6) Drive 1 Technical Data Function Motor - Air flow and drum drive (M5) Motor - Air flow and drum drive (M5) Condensate pump (M5) 2 Function Level sensing - Float switch - Condensate (B8/7) Fascia panel 1 Technical Data Function Overriding time control No-load recognition Insufficient air flow measurement , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
4 2 DTD no Time of day programmable function Extended cooling phase programmable function Residual moisture level adjustment programmable function Clean the airways warning modification programmable function Automatic programmable function Clean filters programmable function Clean heat exchanger programmable function Residual moisture level display programmable function Cool air free programmable function, with payment system operation Payment system programmable function Operator code programmable function Signal to payment system socket (X1/1) pin 7 programmable function Overriding time control modification programmable function with payment system operation Programme lock programmable function with payment system operation Cool air timed programme maximum duration setting programmable function Warm air timed programme maximum duration setting programmable function Delay start programmable function Language programmable function Standard settings programmable function Fault Repair Warning indication: Clean filter Warning indication: Clean heat exchanger Warning indication: Adjust the load The drum is empty or the laundry too dry Demonstration mode active Fault indication: Drain fault Check the drain path Fault indication: Clean the airways Fault indication: Technical fault Fault code F1, heater bank NTC sensor short-circuited Fault code F2, heater bank NTC sensor open-circuited Fault code F3, fill ring NTC sensor short-circuited Fault code F4, fill ring NTC sensor open-circuited Fault code F41, faulty EEPROM / data fault Fault code F43, model type not programmed Fault code F45, faulty flash RAM/ data fault Fault code F46, display fault Fault code F47, communication fault between selection module (EW) and power-programme module (ELP) Fault code F50, motor stationary and heating operates for 5 s Fault code F55, overriding time limit exceeded (approx. 180 min) Fault code F66, air leakage fault Service Programming mode summary Programming mode summary Demonstration mode activation / deactivation Demonstration mode activation / deactivation Service mode summary This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
5 DTD no Service mode summary Electrical components 2 Function Mains terminal strip (X3/1) Payment system socket (X1/1) Payment system Central control via RS 232 interface with 9-pole plug Service Fitting payment system on machine lid Payment system (programme operation) Payment system (timed operation) Central control via RS 232 interface , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
6 4 DTD no This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
7 DTD no A-1 A Warning and Safety Instructions 1 General information Service and repair work should only be carried out by suitably qualified persons in accordance with all appropriate local and national safety regulations. Servicing, modification, testing and maintenance of electrical appliances should only be carried out in accordance with all appropriate legal requirements, accident prevention regulations and valid standards. All regulations of the appropriate utility supply companies and standards relating to safety (not limited to electrical safety) are to be complied with. Before any service work is commenced, the machine must be disconnected from the mains. Even with the machine switched off, mains power may be applied to some components. A general visual check should always be carried out , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
8 A-2 DTD no Risk of injury due to sharp edges There may be a risk of injury due to sharp edges. Protective gloves should be worn and the edge protection, Mat. no , should be used. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
9 DTD no A-3 3 Electrical connection via plug connector It is always recommended to make electrical connection via a plug and socket so that electrical safety checks, e.g. during repair or service work, can be carried out easily. The socket must be accessible after machine installation. This also applies even if an on-site mains switch is also already provided. For models with a total connected load greater than 9 kw, an additional on-site mains switch must also be provided. Electrical connection must be carried out in accordance with all appropriate legal requirements, accident prevention regulations and valid standards , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
10 A-4 DTD no Touch current measurement x Note On machines with an earth connection, touch current leakage measurements should be carried out on all accessible conductive parts that are not connected to the earth. Warning! Touch current measurement should only be carried out after the earth connection of the unit under test has been checked and found to be satisfactory! Dangerous voltages may exist on defective machines as well as on accessible conductive parts that are not connected to earth! Note Touch current measurement should be carried out on the following accessible conductive parts: None. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
11 DTD no B-1 B Modification History When? Who? What? Olaf Meyer zu Drewer Initial compilation , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
12 B-2 DTD no This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
13 DTD no C-1 C Technical Data Semi-commercial machines Casing Door Drum, bearing, sensors, heater bank Fill ring / Air guide Drive, fan Fascia panel, control module Condenser box - Condenser dryer only Condensate pump (M13) - Condenser dryer only Electrical connection - German standard models only Drying technology PT 7135 C PT 7136 PT 5135 C PT 5136 Condenser dryer Vented dryer Condenser dryer Vented dryer Generation 2000, spaceframe construction - Filter flap / Cover - Filter flap / Cover Door opened mechanically via pushbutton switch with Bowden cable Door lock contact switch (A2) Maximum load, dry laundry, 6.5 kg Drum volume 130 l Heater bank (R1, R2, R3), 3-filament, 2-phase 3.45 kw (1.94 kw kw, 0.8 kw) Temperature limiter (F2), 170 C, manual reset Heater bank (R1, R2, R3), 3-filament, 3-phase 6.14 kw (1.94 kw kw, 2.1 kw) NTC temperature sensor in heater bank behind perforated rear drum panel (2R30) Temperature limiter (F2), 175 C, manual reset Heater bank (R1, R2, R3), 3-filament, 2-phase 3.45 kw (1.94 kw kw, 0.8 kw) NTC temperature sensor in heater bank behind perforated rear drum panel (2R30) Temperature limiter (F2), 170 C, manual reset Drying air NTC temperature sensor in fill ring, 1R30 Drum light (H3/6). Bulb: 230 V, 15 W. Activation via relay on power module. Motor for air flow and drum drive (M5). Power consumption approx. 250 W Graphic LCD display, 240 x 64 lines, multifunction selector Electronic selection module (2N1): EW 421 Fine-wire fuse (F7) 6.3 A, slow-blow Electronic selection module (2N1): EW Finger safety switch (S32) on the fluff filter flap Time- and level- controlled Max. drain pump head height 1 m, max. drain hose length 3 m Power consumption approx. 25 W Heater bank (R1, R2, R3), 3-filament, 3-phase 6.14 kw (1.94 kw kw, 2.1 kw) NTC temperature sensor in heater bank behind perforated rear drum panel (2R30) Temperature limiter (F2), 175 C, manual reset Graphic LCD display, 132 x 48 lines, rotary selector switch Electronic selection module (2N1): EW Time- and levelcontrolled - Max. drain pump head height 1 m, max. drain hose length 3 m - Power consumption approx. 25 W Connection cable length 1.6 m Relay - Heating (K1), single armature relay, load rating 16 A, solenoid: 12 V DC, 200 Ω Electronic powerprogramme module (1N1), ELP 320 with ID966 Electronic powerprogramme module (1N1), ELP 321 with ID966 Electronic powerprogramme module (1N1), ELP 390 with ID966 Electronic selection module (2N1): EW Electronic powerprogramme module (1N1), ELP 391 with ID966 Can be updated via serial optical PC interface Tangle prevention: Reversing cycle times via random generator Residual moisture indication: Laundry conductivity measurement process, time-left correction Air path blockage monitoring via heater bank temperature sensor (2R30) behind perforated rear drum panel and fill ring temperature sensor (1R30) Table 1: Semi-commercial tumble dryer (KG-TR), 2000 series , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
14 C-2 DTD no This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
15 DTD no D-1 D Layout of Electrical Components x PT 7135 C Layout 1 1 (Z1) Interference suppression capacitor 2 X3/1 Mains terminal strip 3 (1K1/1, 2K1/1, 3K1/1) Heating relay 4 (X1/1) Payment system socket P6 Payment system Programme unit P8 Payment system Time unit 5 (1N1) Power-programme module (ELP) 6 (2N1) Selection module (EW) 7 (F7) Fine-wire fuse 8 (S4) Pushbutton - Door (Bowden cable) 9 (H3/6) Light - Drum 10 (1F2, 2F2) Temperature limiter , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
16 D-2 DTD no (2R30) Drying air NTC temperature sensor - In heater bank behind perforated rear drum panel 12 (R1, R2, R3) Heater bank 13 (A2) Door lock 14 (C5) Capacitor - Drum drive 15 (M5) Motor - Air flow and drum drive 16 (1R30) Drying air NTC temperature sensor - Fill ring 17 (M13) Motor - Condensate pump 18 (B8/7) Float switch - Condensate 19 (B3/1) Sensor - Residual moisture This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
17 DTD no D-3 PT 5135 C x Layout 2 1 (Z1) Interference suppression capacitor 2 X3/1 Mains terminal strip 3 (1K1/1, 2K1/1, 3K1/1) Heating relay 4 (X1/1) Payment system socket P6 Payment system Programme unit P8 Payment system Time unit 5 (1N1) Power-programme module (ELP) 6 (2N1) Selection module (EW) 7 (F7) Fine-wire fuse 8 (S4) Pushbutton - Door (Bowden cable) 9 (H3/6) Light - Drum 10 (1F2, 2F2) Temperature limiter 11 (2R30) Drying air NTC temperature sensor - In heater bank behind perforated rear drum panel , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
18 D-4 DTD no (R1, R2, R3) Heater bank 13 (A2) Door lock 14 (C5) Capacitor - Drum drive 15 (M5) Motor - Air flow and drum drive 16 (1R30) Drying air NTC temperature sensor - Fill ring 17 (M13) Motor - Condensate pump 18 (B8/7) Float switch - Condensate 19 (B3/1) Sensor - Residual moisture This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
19 DTD no D-5 PT 7136 x Layout 3 1 (Z1) Interference suppression capacitor 2 (X3/1) Mains terminal strip 3 (1K1/1, 2K1/1, 3K1/1) Heating relay 4 (X1/1) Payment system socket P6 Payment system Programme unit P8 Payment system Time unit 5 (M2) Fan (additional external cooling fan for Sweden) 6 (1N1) Power-programme module (ELP) 7 (2N1) Selection module (EW) 8 (F7) Fine-wire fuse 9 (S4) Pushbutton - Door (Bowden cable) 10 (H3/6) Light - Drum 11 (2R30) Drying air NTC temperature sensor - In heater bank behind perforated rear drum panel , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
20 D-6 DTD no (A2) Door lock 13 (C5) Capacitor - Drum drive 14 (M5) Motor - Air flow and drum drive 15 (S32) Safety switch - Finger protection 16 (1R30) Drying air NTC temperature sensor - Fill ring 17 (R1, R2, R3) Heater bank 18 (1F2, 2F2, 3F2) Temperature limiter (vented operation) 19 (B3/1) Sensor - Residual moisture This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
21 DTD no D-7 PT 5136 x Layout 4 1 (Z1) Interference suppression capacitor 2 (X3/1) Mains terminal strip 3 (1K1/1, 2K1/1, 3K1/1) Heating relay 4 (X1/1) Payment system socket P6 Payment system Programme unit P8 Payment system Time unit 5 (M2) Fan (additional external cooling fan for Sweden) 6 (1N1) Power-programme module (ELP) 7 (2N1) Selection module (EW) 8 (F7) Fine-wire fuse 9 (S4) Pushbutton - Door (Bowden cable) 10 (H3/6) Light - Drum 11 (2R30) Drying air NTC temperature sensor - In heater bank behind perforated rear drum panel , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
22 D-8 DTD no (A2) Door lock 13 (C5) Capacitor - Drum drive 14 (M5) Motor - Air flow and drum drive 15 (1R30) Drying air NTC temperature sensor - Fill ring 16 (R1, R2, R3) Heater bank 17 (1F2, 2F2, 3F2) Temperature limiter 18 (B3/1) Sensor - Residual moisture This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
23 DTD no Door x , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
24 020-2 DTD no Function 2.1 Door lock (A2) Door release via Bowden cable. An open door is registered via a microswitch in the door lock. Microswitch in door lock (A2): Drum door open = Contact open. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
25 DTD no Drum, bearing, sensors, heater bank x , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
26 030-2 DTD no Technical Data Heater bank (R1, R2, R3) Condenser dryer Vented dryer Heater rating with 230 V connection Table 1: Heater bank (R1, R2, R3) 3-filament, 2-phase 1.94 kw kw kw = 3.45 kw 3-filament, 3-phase 1.94 kw kw = 6.14 kw Temperature ( C) Resistance (kω) This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
27 DTD no Temperature ( C) Resistance (kω) Table 2: NTC temperature sensor - Heater bank (2R30) - Resistance values Temperature ( C) Resistance (kω) Table 3: NTC temperature sensor - Fill ring (1R30) - Resistance values , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
28 030-4 DTD no Function 2.1 Heating control (R1, R2, R3) Safety features: If the fill ring temperature sensor (1R30) is defective, the heating is not activated. The heating is switched off as soon as the heating relay is switched on for more than 5 s without the fan relay being activated. The heating has a reswitch-on delay of 10 s and is switched off before, during and after a reversing pause. 2.2 Temperature limiter (F2) Vented dryer: Three 3/4 inch temperature limiters, 175 C, with manual reset via pushbutton, located in the heater channel next to the heater bank. Condenser dryer: Two closed 3/4 inch temperature limiters, 170 C, with manual reset via pushbutton, located on the heater bank. 2.3 NTC temperature sensor - Fill ring (1R30) If the fill ring temperature sensor registers a drying air temperature less than - 15 C or greater than 160 C, it is assumed to be defective. 2.4 NTC temperature sensor - Heater bank (2R30) An open circuit at the heater bank temperature sensor (2R30) can only be registered with a temperature greater than 14 C. As during operation lower temperatures can exist, the sensor is only checked when the heating has operated for at least 1 min. If a short circuit exists at the heater bank temperature sensor (2R30), this is equivalent to a temperature of 250 C and the heating is immediately switched off. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
29 DTD no Light - Drum (H3/6) Lighting is time-controlled. It is switched on approx. 1 s after the door is opened. Switch off delay: 5 min. When the door is closed, the lighting is always switched off , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
30 030-6 DTD no This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
31 DTD no Drive x , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
32 040-2 DTD no Technical Data Cooling fan flow rate Condenser dryer Vented dryer Cooling air 300 m 3 / h Drying air 120 m 3 / h 300 m 3 / h. With 20 m vent duct > 200 m 3 / h Table 1 This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
33 DTD no Function 2.1 Motor - Air flow and drum drive (M5) PT 7135 C, PT 5135 C The motor drives the drum, drying air fan and cooling air fan at the same time. 2.2 Motor - Air flow and drum drive (M5) PT 7136, PT 5136 The motor drives the drum and drying air fan at the same time , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
34 040-4 DTD no This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
35 DTD no Condensate pump (M5) x PT 7135 C, PT 5135 C , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
36 070-2 DTD no Function 2.1 Level sensing - Float switch - Condensate (B8/7) Level sensing is via a reed switch. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
37 DTD no Fascia panel x , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
38 080-2 DTD no Technical Data PT 7135 C and PT 7136 Extra dry Cottons Minimum iron Automatic Outerwea Shirts Denim Proofing Normal + - 2% 0% -2% Normal 0% 2% 0% 2% 0% 2% 0% Hand iron r 8% 8% 8% 8% 8% 8% Hand iron rr 12% Machine iron 20% Table 1: Standard residual moisture levels PT 5135 C and PT 5136 Cottons Minimum iron Automatic Outer wear Shirts Denim Proofing Towelling Extra dry Normal + - 2% 0% - 2% - 2% Normal 0% 2% 0% 2% 0% 0% 0% Hand iron r 8% 8% 8% 8% 8% 8% Machine iron 20% Table 2: Standard residual moisture levels Residual moisture level adjustment programmable function, see Residual moisture level adjustment programmable function. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
39 DTD no Function 2.1 Overriding time control After programme start, an overriding time control of approx. 180 min applies to all residual moisture drying programmes. After this time has expired, the drying programme is cancelled and the cooling stage for faults is activated. The anti-crease action phase is cancelled. The fault is saved and can be called up in the service mode. 2.2 No-load recognition No-load recognition and registration of very dry laundry can only take place with residual moisture drying programmes. The programme is cancelled, a cooling phase is started and the buzzer sounds intermittently. 2.3 Insufficient air flow measurement During warming up, the temperature increase at the heater bank temperature sensor (2R30) is monitored. If the air path is blocked, this temperature increases rapidly and a fault is registered. The fault indication Insufficient air/leakage is displayed. 2.4 Time of day programmable function This is used to set the time of day display , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
40 080-4 DTD no Extended cooling phase programmable function An extended cooling phase means that the laundry temperature is lower at the end of the programme. A lower laundry temperature reduces the perception of dampness in the load. Extended cooling has no effect with timed programmes. 2.6 Residual moisture level adjustment programmable function The standard residual moisture levels can be modified to make them dryer or damper. PT 7135 C and PT 7136: Standard residual moisture levels, see 080 Table 1. PT 5135 C and PT 5136: Standard residual moisture levels, see 080 Table 2. x Display bar Residual moisture adjustment Damper 3 Damper 2 Damper 1 Normal Dryer 1 Dryer 2 Dryer 3 Table 3: Residual moisture level adjustment - Cottons Display bars Residual moisture adjustment Damper 3 Damper 2 Damper 1 Normal Dryer 1 Dryer 2 Dryer 3 Table 4: Residual moisture level adjustment - Minimum iron Display bars Residual 26% 25% 24% 23% 22% 21% 20% 19% 18% 17% 16% moisture adjustment Damper Normal Dryer Table 5: Residual moisture level adjustment - Cottons, machine iron This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
41 DTD no Clean the airways warning modification programmable function This function can be used to modify the circumstances under which the Clean the airways warning is displayed to suit individual requirements, see the operating instructions or programming mode. PT 7135 C and PT 7136: Service Dept. programming mode, see Programming mode summary, PT 7136 vented dryer: The warning is reset via the finger protection safety switch (S32) after opening the fluff filter flap. PT 5135 C and PT 5136: Service Dept. programming mode, see Programming mode summary, Automatic programmable function PT 7135 C, PT 7136, PT 5135 C, PT 5136 This function can be used to add the Automatic programme to the programme list. 2.9 Clean filters programmable function PT 7136 When drying laundry which develops high levels of fluff, frequent cleaning of the large surface area filter is necessary. With a vented dryer this warning is shown at intervals and indicates that the filters must be cleaned regularly. This function can be used to modify the circumstances under which the Clean filters warning is displayed to suit individual requirements, see the operating instructions or programming mode. Service Dept. programming mode, see Programming mode summary, , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
42 080-6 DTD no Clean heat exchanger programmable function PT 7135 C, PT 5135 C With a condenser dryer this warning is shown at intervals and indicates that the heat exchanger must be cleaned regularly. This function can be used to modify the circumstances under which the Clean heat exchanger warning is displayed to suit individual requirements, see the operating instructions or programming mode. PT 7135 C: Service Dept. programming mode, see Programming mode summary, PT 5135 C: Service Dept. programming mode, see Programming mode summary, Residual moisture level display programmable function PT 7135 C, PT 7136 This function can be used to programme the machine to display the current residual moisture level of the load being dried in percent Cool air free programmable function, with payment system operation With payment system operation, this function can be set to provide the Cool air programme at no charge. The Cool air free programmable function is only available with payment system operation. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
43 DTD no Payment system programmable function This is used to set the type of payment system. The appropriate operating procedure is shown in the display. For payment system details, see Payment system. PT 7135 C and PT 7136 only: For central control via RS 232 interface, see Central control via RS 232 interface with 9-pole plug 2.14 Operator code programmable function With installation in a launderette, the domestic operation programmable functions can be blocked. Option code not required (domestic use): Domestic programmable functions are freely available. Supervisor programmable functions are not accessible. Option code required (supervisor): Access to domestic and supervisor programmable functions via code entry. The code is freely selectable. If the code is no longer known to the supervisor, then it can be reset to 000 by resetting all programmable functions to the standard settings Signal to payment system socket (X1/1) pin 7 programmable function In order to reset an external payment system at the end of a programme, the machine provides a mains voltage signal for 5 s applied to the payment system connection socket (X1/1), pin 7 (payment system contact) , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
44 080-8 DTD no Overriding time control modification programmable function with payment system operation To reduce the possibility of unauthorised manipulation with payment system operation, the overriding time can be reduced. For overriding time control details, see Overriding time control Programme lock programmable function with payment system operation To reduce the possibility of unauthorised manipulation with payment system operation, the programme lock feature can be activated. Depending on the set options, the programme will be locked immediately the programme is started or after a certain period. If the door is opened when the programme is locked, the programme will be cancelled and the payment already made will be lost. To ensure that laundry can still be added, the programme lock can be set to become active after a certain time has elapsed Cool air timed programme maximum duration setting programmable function This is used to set the maximum duration of the Cool air timed programme. PT 7135 C and PT 7136: The programme duration can be reduced via the multifunction selector switch but cannot be increased again. PT 5135 C and PT 5136: The programme duration can be reduced via the + / - buttons, but cannot be increased again. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
45 DTD no Warm air timed programme maximum duration setting programmable function This is used to set the maximum duration of the Warm air timed programme. PT 7135 C and PT 7136: The programme duration can be reduced via the multifunction selector switch but cannot be increased again. PT 5135 C and PT 5136: The programme duration can be reduced via the + / - buttons, but cannot be increased again Delay start programmable function This is used to activate the delay start feature. If the delay start feature is deactivated, the display shows the time of day in the style that has been set with the time of day programmable function Language programmable function PT 7135 C, PT 7136 International: Multilingual start screen, e.g. for multilingual countries and camp sites. The desired language is selected before the basic programme menu and is applicable for only one programme. The Sort language programmable function is available to select and sort four favourite languages for international installations Standard settings programmable function To reset all programmable functions to standard settings. The code no. for accessing the supervisor level will be reset to , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
46 DTD no Fault Repair 3.1 Warning indication: Clean filter PT 7136 Cause This warning is given at certain intervals as a reminder that the filters must be cleaned. Remedy x Note Clean the fluff filters regularly, see the operating instructions. A Clean both parts of the large surface area filter behind the service panel and the filters in the door opening. Cause Clean filter warning shown too soon/late. Remedy A The circumstances under which the Clean filters warning is displayed can be modified to suit individual requirements, see the operating instructions or programming mode. A Service Dept. programming mode, see Programming mode summary, This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
47 DTD no Warning indication: Clean heat exchanger PT 7135 C, PT 5135 C Cause With a condenser dryer this warning is shown at intervals and indicates that the heat exchanger must be cleaned regularly. Remedy x Note Clean the heat exchanger regularly, see the operating instructions. A Clean the heat exchanger. Cause Clean heat exchanger warning shown too soon/late. Remedy A The circumstances under which the Clean heat exchanger warning is displayed can be modified to suit individual requirements, see the operating instructions or programming mode. A PT 7135 C: Service Dept. programming mode, see Programming mode summary, A PT 5135 C: Service Dept. programming mode, see Programming mode summary, , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
48 DTD no Warning indication: Adjust the load The drum is empty or the laundry too dry Symptom This warning can only be displayed with residual moisture drying programmes (i.e. not timed drying). The programme is cancelled, a cooling phase is started and the buzzer sounds intermittently. This warning is cancelled when the door is opened. Cause The drum is empty or loaded with a few small items only. The residual moisture sensing circuit has high resistance and the sensing system registers no load (no load recognition). This is not a technical fault. Remedy A Modify the load or select a timed drying programme. Cause Residual moisture sensor (B3/1) defective. Residual moisture sensor check A PT 7135 C and PT 7136: Check the residual moisture sensor circuit for low resistance (continuity), see the service mode Service mode summary, A PT 5135 C and PT 5136: Check the residual moisture sensor circuit for low resistance (continuity), see the service mode Service mode summary, A No load recognition, see No-load recognition. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
49 DTD no Demonstration mode active Symptom A programme start is not possible and the programming and service modes cannot be accessed. Cause The demonstration mode is active. Remedy A PT 7135 C and PT 7136: Demonstration mode deactivation, see Demonstration mode activation / deactivation, A PT 5135 C and PT 5136: Demonstration mode deactivation, see Demonstration mode activation / deactivation, Fault indication: Drain fault Check the drain path Symptom Applicable to condenser dryer only. The programme is cancelled, a cooling phase is started and the buzzer sounds intermittently. This warning is cancelled when the door is opened. Cause Float switch - Condensate (B8/7) in the condensate pump housing is defective (short-circuited). Remedy A Check the float switch - Condensate (B8/7). Exchange it if necessary. A PT 7135 C and PT 7136: Service mode, see Service mode summary, A PT 5135 C and PT 5136: Service mode, see Service mode summary, Cause Condensate pump (M13) defective , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
50 DTD no Remedy A Check the condensate pump (M13). Exchange it if necessary. A PT 7135 C and PT 7136: Service mode, see Service mode summary, A PT 5135 C and PT 5136: Service mode, see Service mode summary, Cause The condensate drainage path is blocked. Remedy A Check the drainage path for blockages. Repair as necessary. 3.6 Fault indication: Clean the airways Symptom The programme continues normally or is interrupted. The fault is indicated at the end of the cooling down phase. The fault is saved in the fault memory, see Fault code F66, air leakage fault, PT 7135 C and PT 7136: This warning is cancelled when the door is opened. Cause Air paths are clogged. Insufficient air flow registered, see Insufficient air flow measurement. Remedy x Note Check and clean the filters regularly, see the operating instructions. A Clean the fluff filters in the door cap and door fill ring. A Condenser dryer: Remove the heat exchanger and clean it. A Check and clean the air paths. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
51 DTD no Cause Clean the airways warning shown too early/late. Remedy A The point at which the Clean the airways warning is shown can be adjusted to suit the needs of the operator, see the operating instructions or programming mode. A PT 7135 C and PT 7136: For Service Dept. programming mode see Programming mode summary, A PT 5135 C and PT 5136: For Service Dept. programming mode see Programming mode summary, Fault indication: Technical fault Symptom In normal operation mode the display shows Technical fault. Programme interruption, cooling down phase, intermittent buzzer operation. This fault indication is deleted by pressing the multifunction selector switch. Cause The power-programme module (ELP) or selection module (EW) has registered a fault. The power-programme module (ELP) interrupts the programme. The displayed fault is the reason for the programme interruption. Remedy A PT 7135 C and PT 7136: For fault memory check, see the Service mode, Service mode summary, A PT 5135 C and PT 5136: For fault memory check, see the Service mode, Service mode summary, A Check the Mat. nos. to verify that the correct selection module (EW) and power-programme module (ELP) are fitted. A Check the electrical connection between the power-programme module (ELP) and selection module (EW) , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
52 DTD no Fault code F1, heater bank NTC sensor short-circuited Symptom In normal operation mode the display shows Technical fault. Programme interruption, cooling down phase, intermittent buzzer operation. Only the Cool air timed programme can be operated. This fault indication is deleted by pressing the multifunction selector switch. Cause Heater bank temperature sensor (2R30) short-circuited (> 250 C). Remedy A Check the heater bank temperature sensor (2R30), its leads and its plug connections for short or open circuit. A Check the heater bank temperature sensor (2R30) for correct performance, see 030 Table Fault code F2, heater bank NTC sensor open-circuited Symptom In normal operation mode the display shows Technical fault. Programme interruption, cooling down phase, intermittent buzzer operation. Only the Cool air timed programme can be operated. This fault indication is deleted by pressing the multifunction selector switch. Cause Heater bank temperature sensor (2R30) open-circuited (< 20 C). Only registered after the heating has been switched on for at least 1 min. Remedy A Check the heater bank temperature sensor (2R30), its leads and its plug connections for short or open circuit. A Check the heater bank temperature sensor (2R30) for correct performance, see 030 Table 2. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
53 DTD no Cause Heater bank not heating. Remedy A Check the heater bank (R) for short or open circuit. Cause Heating relay (K1). Remedy A Check the heating relay (K1). Cause Temperature limiter (F2). Remedy A Check the temperature limiter F2 for continuity Fault code F3, fill ring NTC sensor short-circuited Symptom In normal operation mode the display shows Technical fault. Programme interruption, cooling down phase, intermittent buzzer operation. Only the Cool air timed programme can be operated. This fault indication is deleted by pressing the multifunction selector switch. Cause Fill ring temperature sensor (1R30) short-circuited (> 160 C). Remedy A Check the fill ring temperature sensor (1R30), its leads and its plug connections for short or open circuit. A Check the fill ring temperature sensor (1R30) for correct performance, see 030 Table , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
54 DTD no Fault code F4, fill ring NTC sensor open-circuited Symptom In normal operation mode the display shows Technical fault. Programme interruption, cooling down phase, intermittent buzzer operation. Only the Cool air timed programme can be operated. This fault indication is deleted by pressing the multifunction selector switch. Cause Fill ring temperature sensor (1R30) open-circuited (< 15 C). Remedy A Check the fill ring temperature sensor (1R30), its leads and its plug connections for short or open circuit. A Check the fill ring temperature sensor (1R30) for correct performance, see 030 Table Fault code F41, faulty EEPROM / data fault Symptom The programme operates with default values. In normal operation mode the display shows Technical fault. Programme interruption, cooling down phase, intermittent buzzer operation. This warning is cancelled when the door is opened. Cause Faulty EEPROM / data fault. Remedy A If there is no functional fault, a remedy is not required. A Otherwise exchange the power-programme module (1N1, ELP). This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
55 DTD no Fault code F43, model type not programmed Cause In normal operation mode this fault is not indicated via the display. The selection module (EW) and power-programme module (ELP) do not match. Remedy A Check the Mat. nos. to verify that the correct selection module (EW) and power-programme module (ELP) are fitted Fault code F45, faulty flash RAM/ data fault Symptom In normal operation mode the display shows Technical fault. Programme interruption, cooling down phase, intermittent buzzer operation. Cause Faulty flash RAM/ data fault. Remedy A Check the Mat. nos. to verify that the correct selection module (EW) and power-programme module (ELP) are fitted. A Reset all programmable functions to standard settings. Then modify the desired programmable functions. A Exchange the power-programme module (ELP) , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
56 DTD no Fault code F46, display fault Symptom Programme interruption, cooling down phase, intermittent buzzer operation. Cause Internal display fault on selection module (EW). Display driver for LCD module defective. Remedy A Exchange the selection module (EW) Fault code F47, communication fault between selection module (EW) and power-programme module (ELP) Symptom In normal operation mode the display shows Technical fault. Programme interruption, cooling down phase, intermittent buzzer operation. With operation with a payment system, the programme end signal is provided at the payment system socket (X1/1) pin 7. Cause Selection module (EW) - Power-programme module (ELP) interface fault. Remedy A Check the electrical connection between the selection module (EW) and power-programme module (ELP). This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
57 DTD no Fault code F50, motor stationary and heating operates for 5 s Symptom The motor for air flow and drum drive (M5) is stationary. This fault occurs in normal operating mode and the following occurs: Programme interruption, cooling down phase, intermittent buzzer operation for 2 min. This warning is cancelled when the door is opened. Cause The heating has operated for longer than 5 s with the motor stationary. This is a power-programme module (ELP) fault. Remedy A Check the motor (M5). A Exchange the power-programme module (ELP) Fault code F55, overriding time limit exceeded (approx. 180 min) Symptom Only applicable to residual moisture programmes. This fault occurs in normal operating mode and the following occurs: Programme interruption, cooling down phase, intermittent buzzer operation for 2 min. This warning is cancelled when the door is opened. For the overriding time limit, see Overriding time control. Cause Laundry too wet or dryer overloaded. Remedy A Spin the laundry more or reduce the quantity. Cause Electrically conductive item in load (e.g. zip). Remedy A Select a hot air drying programme , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
58 DTD no Cause Air path clogged. Remedy A Check and clean the air paths. Cause Heater bank not heating. Remedy A Check the heater bank (R1) for short or open circuit. Cause Heating relay (K1/1). Remedy A Check the heating relay (K1/1). Cause Temperature limiter (F2). Remedy A Check the temperature limiter (F2) for continuity. Cause Residual moisture sensor (B3/1) defective. Residual moisture sensor check A PT 7135 C and PT 7136: Check the residual moisture sensor for high resistance, see service mode Service mode summary, A PT 5135 C and PT 5136: Check the residual moisture sensor for high resistance, see service mode Service mode summary, This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
59 DTD no Fault code F66, air leakage fault Symptom In normal operation mode the display shows Clean the airways. Cause Air path clogged. Insufficient air flow registered, see Insufficient air flow measurement. Remedy A Check and clean the air paths , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
60 DTD no Service 4.1 Programming mode summary PT 7135 C, PT 7136 Initial requirements A Finish or cancel any programme in operation, including the demonstration mode. A Open the door. A Disconnect the fill ring NTC temperature sensor (1R30) plug. x Note If the fill ring NTC temperature sensor (1R30) plug is disconnected at the powerprogramme module (1N1), then power is also no longer supplied to the door lock (A2). In this case the programming mode cannot be accessed. A If the international multilingual start screen is shown, select the desired language. Accessing x Note After it is begun, the accessing procedure must be completed within 10 s. A Press and hold the Start button. A Close the door. A As soon as the Start button flashes, release the Start button. A Immediately press and release the Start button 5 times and at the 5th time hold it pressed in until programmable functions are shown in the display. Acknowledgement indicator Successful accessing of the programming mode is indicated by rapid flashing (5 Hz) of the Start button. The display shows the Service Dept. programmable functions. If the accessing procedure has been unsuccessful, the control automatically reverts to the normal operating mode. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
61 DTD no Options The set option is indicated by a V next to it. A Programmable function selection: Turn the multifunction selector switch to mark the desired function and press the multifunction selector switch to confirm the selection. A Option selection: Turn the multifunction selector switch to mark the desired option and press the multifunction selector switch to confirm the selection. x Note Highlighted options are standard settings. If an electronic module is supplied as a replacement part, the highlighted options should be set to suit the machine in which the module is fitted! , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
62 DTD no x Programmable function Language Sort language Anti-crease action Buzzer Option Language for operating, programming and service modes Select and sort four favourite languages for international installations Off On Off Normal Loud Clock display, see Time of day 24 h clock programmable function 12 h clock am/pm No clock, 24 h Delay start Display contrast Standard contrast setting: Bar diagram level 4 Display brightness Standard brightness setting: Bar diagram level 5 Stand-by On: Display und backlight switched off automatically after 10 min Not in programme in operation: Stand-by only before and after programme but not while it is in operation Extended cooling time, see min Extended cooling phase programmable 2 min function 4 min 6 min 8 min 10 min 12 min 14 min 16 min 18 min Save On: Save option available. Favourite programmes can be allocated to direct selection buttons. Off: Save option not available Residual moisture level adjustment - Cottons Residual moisture level adjustment - Minimum iron Residual moisture level adjustment - Machine iron Clean the airways warning, see Clean the airways warning modification programmable function Automatic programme, see Automatic programmable function The standard residual moisture levels can be modified to make them up to 3 stages dryer or damper, see Residual moisture level adjustment programmable function The standard residual moisture levels can be modified to make them up to 3 stages dryer or damper, see Residual moisture level adjustment programmable function The standard residual moisture levels can be modified to make them dryer or damper, see Residual moisture level adjustment programmable function Off Reduced sensitivity Normal Sensitive On: Automatic programme included in programme list Off: Automatic programme not included in programme list This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
63 DTD no Programmable function Clean filters warning, vented dryers only, see Clean filters programmable function Clean heat exchanger warning, condenser dryers only, see Clean heat exchanger programmable function Residual moisture level display, see Residual moisture level display programmable function Cool air free, with payment system operation, see Cool air free programmable function, with payment system operation Payment system operation, see Payment system programmable function Supervisor level code, see Operator code programmable function Signal to payment system socket (X1/1) pin 7, see Signal to payment system socket (X1/1) pin 7 programmable function Option Off Display after 5 h Display after 10 h Display after 15 h Display after 20 h Display after 25 h Display after 30 h Display after 35 h Display after 40 h Display after 45 h Display after 50 h Display after 55 h Off Display after 100 h Display after 200 h Display after 300 h Display after 400 h Display after 500 h Display after 600 h Display after 700 h Display after 800 h Display after 1000 h Display after 1200 h Display after 1400 h Display after 1600 h Without percentage indication With percentage indication Yes No Off Programme operation (MZK) Timed operation (MZZ) IK 6 (RS 232) RS 232 interface active Code not required. Domestic programmable functions can be modified. Code required. After code entry, domestic and supervisor programmable functions can be modified. At programme end When Start button is released When Start button is released and at programme end , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
64 DTD no Programmable function Overriding time control modification with payment system operation, see Overriding time control modification programmable function with payment system operation Programme lock with payment system operation after releasing the Start button, see Programme lock programmable function with payment system operation Cool air timed programme maximum duration, see Cool air timed programme maximum duration setting programmable function Warm air timed programme maximum duration, see Warm air timed programme maximum duration setting programmable function Delay start, see Delay start programmable function Language setting, see Language programmable function Standard settings, see Standard settings programmable function Option 120 min 135 min 150 min 165 min 180 min 195 min 210 min 225 min 240 min None Immediately 1 min 2 min 3 min 4 min 5 min 10 min 20 min 30 min 40 min 50 min 60 min 70 min 80 min 90 min 100 min 110 min 120 min 15 min 20 min 25 min 30 min 35 min 40 min 45 min 50 min 55 min 60 min 90 min 120 min Active Inactive National International, additional welcoming menu (favourite languages) Reset all programmable functions to standard settings Table 6: Programming mode summary This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
65 DTD no Save and quit x Note Confirmed programmable options are saved. A Reconnect the fill ring NTC temperature sensor (1R30) plug. 4.2 Programming mode summary PT 5135 C, PT 5136 Initial requirements A Finish or cancel any programme in operation, including the demonstration mode. A Open the door. A Disconnect the fill ring NTC temperature sensor (1R30) plug. x Note If the fill ring NTC temperature sensor (1R30) plug is disconnected at the powerprogramme module (1N1), then power is also no longer supplied to the door lock (A2). In this case the programming mode cannot be accessed. A During initial commissioning only: Select the desired language. Accessing x Note After it is begun, the accessing procedure must be completed within 10 s. A Press and hold the Start button. A Close the door. A As soon as the Start LED flashes, release the Start button. A Immediately press and release the Start button 5 times and at the 5th time hold it pressed in until the Start LED flashes. Acknowledgement indicator Successful accessing of the programming mode is indicated by rapid flashing (5 Hz) of the Start LED , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
66 DTD no The display shows the Service Dept. programmable functions. If the accessing procedure has been unsuccessful, the control automatically reverts to the normal operating mode. Options A Programmable function selection: Press the + / - buttons as appropriate to mark the desired function and press the OK button to confirm the selection. The set option is indicated by a V next to it. A Option selection: Press the + / - buttons as appropriate to mark the desired option and press the OK button to confirm the selection. x Note Highlighted options are standard settings. If an electronic module is supplied as a replacement part, the highlighted options should be set to suit the machine in which the module is fitted! Programmable function Language Anti-crease action Option Language for operating, programming and service modes On Off Clock display, see Time of day 24 h clock programmable function 12 h clock am/pm No clock, 24 h Delay start Supervisor level Code modification Display contrast Standard contrast setting: Bar diagram level 4 Display brightness Standard brightness setting: Bar diagram level 5 Stand-by On: Display und backlight switched off automatically after 10 min Not in programme in operation: Stand-by only before and after programme but not while it is in operation Buzzer Off Normal Loud Extended cooling time, see min Extended cooling phase programmable 2 min function 4 min 6 min 8 min 10 min 12 min 14 min 16 min 18 min Residual moisture level adjustment - Cottons The standard residual moisture levels can be modified to make them up to 3 stages dryer or damper, see Residual moisture level adjustment programmable function This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
67 DTD no Programmable function Residual moisture level adjustment - Minimum iron Residual moisture level adjustment - Machine iron Clean the airways warning, see Clean the airways warning modification programmable function Clean heat exchanger warning, condenser dryers only, see Clean heat exchanger programmable function Cool air free, with payment system operation, see Cool air free programmable function, with payment system operation Payment system operation, see Payment system programmable function Supervisor level code, see Operator code programmable function Signal to payment system socket (X1/1) pin 7, see Signal to payment system socket (X1/1) pin 7 programmable function Overriding time control modification with payment system operation, see Overriding time control modification programmable function with payment system operation Option The standard residual moisture levels can be modified to make them up to 3 stages dryer or damper, see Residual moisture level adjustment programmable function The standard residual moisture levels can be modified to make them dryer or damper, see Residual moisture level adjustment programmable function Off Reduced sensitivity Normal Sensitive Off Display after 100 h Display after 200 h Display after 300 h Display after 400 h Display after 500 h Display after 600 h Display after 700 h Display after 800 h Display after 1000 h Display after 1200 h Display after 1400 h Display after 1600 h Yes No Off (Delay start possible) Programme operation (MZK) Timed operation (MZZ) RS 232 interface active Code not required. User programmable functions can be modified. Code required. After code entry, supervisor programmable functions can be modified. At programme end When Start button is released When Start button is released and at programme end 120 min 135 min 150 min 165 min 180 min 195 min 210 min 225 min 240 min , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
68 DTD no Programmable function Programme lock with payment system operation after releasing the Start button, see Programme lock programmable function with payment system operation Cool air timed programme maximum duration, see Cool air timed programme maximum duration setting programmable function Warm air timed programme maximum duration, see Warm air timed programme maximum duration setting programmable function Delay start, see Delay start programmable function Automatic programme, see Automatic programmable function Standard settings, see Standard settings programmable function Option None Immediately 1 min 2 min 3 min 4 min 5 min 10 min 20 min 30 min 40 min 50 min 60 min 70 min 80 min 90 min 100 min 110 min 120 min 15 min 20 min 25 min 30 min 35 min 40 min 45 min 50 min 55 min 60 Min 90 min 120 min Active Inactive On: Automatic programme included in programme list Off: Automatic programme not included in programme list Reset all programmable functions to standard settings Table 7: Programming mode summary Save and quit x Note Confirmed programmable options are saved. A Reconnect the fill ring NTC temperature sensor (1R30) plug. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
69 DTD no Demonstration mode activation / deactivation PT 7135 C, PT 7136 Initial requirements A Finish or cancel any programme in operation. A Open the door. A If the international multilingual start screen is shown, select the desired language. Accessing x Note After it is begun, the accessing procedure must be completed within 10 s. A Press and hold the Start button. A Close the door. A As soon as the Start button lights up constantly, after approx. 5 s, release the Start button. x Note During deactivation the Start button does not light up constantly. A Immediately press and hold the Start button again until an appropriate instruction is shown in the display (approx. 5 s). A Follow the instruction shown in the display. Acknowledgement indicator The demonstration programme operates. If the accessing procedure has been unsuccessful, the control automatically reverts to the normal operating mode. Options The demonstration mode programme duration is approx. 90 s. After a short pause, it starts again automatically. x Note After an interruption in the mains supply, the demonstration mode programme begins again automatically , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
70 DTD no Save and quit A Demonstration programme deactivation: Repeat the accessing procedure. 4.4 Demonstration mode activation / deactivation PT 5135 C, PT 5136 Initial requirements A Finish or cancel any programme in operation. A Open the door. Accessing x Note After it is begun, the accessing procedure must be completed within 10 s. A Press and hold the Start button. A Close the door. A As soon as the Start LED lights up constantly, after approx. 5 s, release the Start button. x Note During deactivation the Start button does not light up constantly. A Immediately press and hold the Start button again until an appropriate instruction is shown in the display (approx. 5 s). A Follow the instruction shown in the display. Acknowledgement indicator The demonstration programme operates. If the accessing procedure has been unsuccessful, the control automatically reverts to the normal operating mode. Options The demonstration mode programme duration is approx. 90 s. After a short pause, it starts again automatically. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
71 DTD no x Note After an interruption in the mains supply, the demonstration mode programme begins again automatically. Save and quit A Demonstration programme deactivation: Repeat the accessing procedure. 4.5 Service mode summary PT 7135 C, PT 7136 Initial requirements A Ensure the machine is installed and connected correctly. A Finish or cancel any programme in operation, including the demonstration mode. A Open the door. A If the international multilingual start screen is shown, select the desired language. Accessing x Note After it is begun, the accessing procedure must be completed within 10 s. A Press and hold the Start button. A Close the door. A As soon as the Start button flashes, release the Start button. A Immediately press and release the Start button 3 times and at the 3rd time hold it pressed in until service mode functions are shown in the display. Acknowledgement indicator Successful accessing of the service mode is indicated by slow flashing of the Start button (1 Hz). The display shows the service mode functions. If the accessing procedure has been unsuccessful, the control automatically reverts to the normal operating mode , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
72 DTD no Options A Service function selection: Turn the multifunction selector switch as appropriate. A Service function start and test step advance: Press the multifunction selector switch. x Note The service mode is switched off automatically 30 min after the last service function has been checked. Service function Software version Component / Sensor tested Selection module (EW) ID no. Power-programme module (ELP) ID no. Fault cause Fault code Remedy No fault registered F 0 None required Heater bank NTC sensor shortcircuited Heater bank NTC sensor opencircuited Fill ring NTC sensor shortcircuited Fill ring NTC sensor opencircuited F 1 F 2 F 3 F 4 See Fault code F1, heater bank NTC sensor short-circuited, See Fault code F2, heater bank NTC sensor open-circuited, See Fault code F3, fill ring NTC sensor short-circuited, See Fault code F4, fill ring NTC sensor open-circuited, Faulty EEPROM / data fault F 41 See Fault code F41, faulty EEPROM / data fault, Fault register display 1) and deletion 2) Model type not programmed F 43 See Fault code F43, model type not programmed, Faulty flash RAM/ data fault F 45 See Fault code F45, faulty flash RAM/ data fault, Display fault F 46 See Fault code F46, display fault, Communication fault between EW / ELP electronic modules F 47 See Fault code F47, communication fault between selection module (EW) and power-programme module (ELP), Motor stationary and heating operates for 5 s F 50 See Fault code F50, motor stationary and heating operates for 5 s, Overriding time limit exceeded F 55 See Fault code F55, overriding time limit exceeded (approx. 180 min), Air leakage fault F 66 See Fault code F66, air leakage fault, This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
73 DTD no Service function Component activation Sensor test Operating hours counter display Component / Sensor tested Component activation All components Drive/Fan motor (M5) Heating 1 and drive/fan motor (M5) Condensate pump (M13) (condenser dryer only) Residual moisture sensor (B3/1) circuit, low resistance check Residual moisture sensor (B3/1) circuit, high resistance check Heating 1 and 2, and drive/fan motor (M5) Heating 1, 2 and 3, and drive/fan motor (M5) Payment system socket (X1/1), programme end signal Payment system socket (X1/1), ready signal Additional fan (2M2). Vented dryer only, for external fan. Function tested/machine response Inactive Drum turns with reversing as follows: 10 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.5 s pause, etc. The heating relay 1K1/1 is activated and the drum turns with reversing as follows: 600 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.5 s pause Condensate pump activated Provide an electrical bridge between the drum and a rib Without electrical bridge between the drum and a rib In case of fault: Check the residual moisture sensor circuit. In case of fault: Check the residual moisture sensor circuit. The heating relays 1K1/1 and 2K1/1 are activated, and the drum turns with reversing as follows: 600 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.5 s pause The heating relays 1K1/1, 2K1/1 and 3K1/1 are activated, and the drum turns with reversing as follows: 600 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.5 s pause Mains voltage applied between pin 7 and pin 3 Mains voltage applied between pin 1 and pin 3 Live (phase) and neutral conductors are switched on Sensors State All sensors Inactive Float switch - Condensate (B8/7) No water in condenser box => Float switch not activated => Switch open => Buzzer off Water in condenser box => Float switch activated => Switch closed => Buzzer on Door lock (A2) Door closed => Switch closed => Buzzer on Door open => Switch open => Buzzer off Payment system contact, Connection wire bridge fitted between 1W14 pin 1/2 payment system socket (X1/1) Connection wire bridge not fitted between 1W14 pin 1/2 Finger protection safety switch Flap closed => Switch closed => Buzzer on (S32) (fluff filter flap, vented Flap open => Switch open => Buzzer off dryer only) Power-programme module (ELP) Operating hours display. Time from start of programme, without delay start, until the start of the anti-crease phase. Controls Display / LED test All display points flash at the same time Display background light The backlight flashes on and off (backlight) Buzzer Audible signal Intermittent Condenser dryer: Audible signal Vented Continuous dryer: Buttons Display indication for activated buttons Table 8: Service mode summary 1) If several faults are registered, their codes are shown one after the other in ascending order when the Start button is pressed. 2) Fault code deletion: Press the Start button for longer than 5 s during the fault code display (all stored fault codes are deleted) , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
74 DTD no Quit (without saving) A Open the door. 4.6 Service mode summary PT 5135 C, PT 5136 Initial requirements A Ensure the machine is installed and connected correctly. A Finish or cancel any programme in operation, including the demonstration mode. A Open the door. Accessing x Note After it is begun, the accessing procedure must be completed within 10 s. A Press and hold the Start button. A Close the door. A As soon as the Start LED flashes, release the Start button. A Immediately press and release the Start button 3 times and at the 3rd time hold it pressed in until the Start LED flashes slowly. Acknowledgement indicator Successful accessing of the service mode is indicated by slow flashing of the Start LED (1 Hz). The display shows the service mode functions. If the accessing procedure has been unsuccessful, the control automatically reverts to the normal operating mode. Options A Service function selection: Press the + / - buttons as appropriate. A Service function start and test step advance: Press the OK button. A Back to main level: Press the OK button. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
75 DTD no x Note The service mode is switched off automatically 30 min after the last service function has been checked. Service function Software version Component / Sensor tested Selection module (EW) ID no. Power-programme module (ELP) ID no. Fault cause Fault code Remedy No fault registered F 0 None required Heater bank NTC sensor shortcircuited Heater bank NTC sensor opencircuited Fill ring NTC sensor shortcircuited Fill ring NTC sensor opencircuited F 1 F 2 F 3 F 4 See Fault code F1, heater bank NTC sensor short-circuited, See Fault code F2, heater bank NTC sensor open-circuited, See Fault code F3, fill ring NTC sensor short-circuited, See Fault code F4, fill ring NTC sensor open-circuited, Faulty EEPROM / data fault F 41 See Fault code F41, faulty EEPROM / data fault, Fault register display 1) and deletion 2) Model type not programmed F 43 See Fault code F43, model type not programmed, Faulty flash RAM/ data fault F 45 See Fault code F45, faulty flash RAM/ data fault, Display fault F 46 See Fault code F46, display fault, Communication fault between EW / ELP electronic modules F 47 See Fault code F47, communication fault between selection module (EW) and power-programme module (ELP), Motor stationary and heating operates for 5 s F 50 See Fault code F50, motor stationary and heating operates for 5 s, Overriding time limit exceeded F 55 See Fault code F55, overriding time limit exceeded (approx. 180 min), Air leakage fault F 66 See Fault code F66, air leakage fault, , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
76 DTD no Service function Component / Sensor tested Component activation All components Drive/Fan motor (M5) Heating 1 and drive/fan motor (M5) Condensate pump (M13) (condenser dryer only) Function tested/machine response Inactive Drum turns with reversing as follows: 10 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.5 s pause, etc. The heating relay 1K1/1 is activated and the drum turns with reversing as follows: 600 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.5 s pause Condensate pump activated Residual moisture sensor (B3/1) circuit, low resistance check Provide an electrical bridge between the drum and a rib In case of fault: Check the residual moisture sensor circuit. Component activation Residual moisture sensor (B3/1) circuit, high resistance check Without electrical bridge between the drum and a rib In case of fault: Check the residual moisture sensor circuit. Heating 1 and 2, and drive/fan motor (M5) Heating 1, 2 and 3, and drive/fan motor (M5) Payment system socket (X1/1), programme end signal Payment system socket (X1/1), ready signal Additional fan (2M2). Vented dryer only, for external fan. Sensors All sensors The heating relays 1K1/1 and 2K1/1 are activated, and the drum turns with reversing as follows: 600 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.5 s pause The heating relays 1K1/1, 2K1/1 and 3K1/1 are activated, and the drum turns with reversing as follows: 600 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.5 s pause Mains voltage applied between pin 7 and pin 3 Mains voltage applied between pin 1 and pin 3 Live (phase) and neutral conductors are switched on State Inactive Float switch - Condensate (B8/7) No water in condenser box => Float switch not activated => Switch open => Buzzer off Water in condenser box => Float switch activated => Switch closed => Buzzer on Sensor test Door lock (A2) Payment system contact, payment system socket (X1/1) Finger protection safety switch (S32) (fluff filter flap, vented dryer only) Door closed => Switch closed => Buzzer on Door open => Switch open => Buzzer off Connection wire bridge fitted between 1W14 pin 1/2 Connection wire bridge not fitted between 1W14 pin 1/2 Flap closed => Switch closed => Buzzer on Flap open => Switch open => Buzzer off Operating hours counter display Power-programme module (ELP) Operating hours display. Time from start of programme, without delay start, until the start of the anti-crease phase. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
77 DTD no Service function Component / Sensor tested Controls Display / LED test All display points flash at the same time Alle LEDs and the illuminated switch surround flash at the same time Display background light The backlight flashes on and off (backlight) Buzzer Audible signal Intermittent Condenser dryer: Audible signal Vented Continuous dryer: Buttons Display indication for activated buttons Rotary selector switch (DWS) Display indication for programme positions test Table 9: Service mode summary 1) If several faults are registered, their codes are shown one after the other in ascending order when the Start button is pressed. 2) Fault code deletion: Press the Start button for longer than 5 s during the fault code display (all stored fault codes are deleted). Quit (without saving) A Open the door , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
78 DTD no This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
79 DTD no Electrical components x , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
80 090-2 DTD no Function 2.1 Mains terminal strip (X3/1) PT 7136, PT 5136 Depending on the country version, the mains terminal strip (X3/1) has a 4-/5-pole connection cable with strain relief. 2.2 Payment system socket (X1/1) x Payment system socket (X1/1) - Tumble dryer side Potential Pin Voltage supply switched by tumble dryer (ready for operation L` 1 signal) Start permitted by payment system L` 2 Voltage supply direct for payment system N 3 Voltage supply direct for payment system L 4 Neutral switched by payment system - Time unit N` 5 Direct earth conductor PE 6 Start reset signal / Time stop / Programme end signal L` 7 Table 1: Payment system socket (X1/1) pin allocation 2.3 Payment system The tumble dryer is pre-fitted with the requirements for operation in conjunction with a payment system. Payment system (programme operation): The payment system provides the machine with a start permitted signal. After the programme has been started, it continues without further influence from the payment system. For further details, see Payment system (programme operation), Payment system (timed operation): The payment system provides the machine with a constant operation permitted signal throughout the period of timed operation that has been purchased. The programme continues so long as the signal is provided. If the signal is interrupted, the programme and time left are stopped and the machine components are switched off. For further details, see Payment system (timed operation), This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
81 DTD no Central control via RS 232 interface with 9-pole plug PT 7135 C, PT 7136 Possible to use one central control/payment system. Control data can be read and modified. For further details, see Central control via RS 232 interface, , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
82 090-4 DTD no Service 4.1 Fitting payment system on machine lid A Remove the machine lid. x Fig. 1 Warning! When drilling through the machine lid, take care to not drill into the surface on which it is resting! A Drill 4 fixing holes through the machine lid in accordance with the payment system template. x Fig. 2 A Place the plastic underlay on the machine lid. Secure the payment system to the lid on the underlay using the screws, washers, retaining rings and nuts provided. A Refit the machine lid. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
83 DTD no Payment system (programme operation) x Note The instructions given in the documentation provided with the payment system must be followed. Fig. 3 A Open the pre-punched opening/s in the rear casing for the electrical connections as necessary. x Warning! Take care to lay wires such that they cannot be damaged by sharp edges. A Fit the appropriate through-feed parts on the wires. Secure the through-feeds on the rear casing. A Lay the payment system wire to the payment system socket (X1/1). A At the payment system socket (X1/1), cut through the wire bridge 1W14 between pins 1 and 2. Insulate the wire ends. A Set the tumble dryer payment system programmable option to Programme operation. A PT 7135 C and PT 7136: For Service Dept. programming mode see Programming mode summary, A PT 5135 C and PT 5136: For Service Dept. programming mode see Programming mode summary, A Fit the payment system on the machine lid, see Fitting payment system on machine lid, , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
84 090-6 DTD no Payment system (timed operation) x Note The instructions given in the documentation provided with the payment system must be followed. Warning! The connection has been modified. Danger of short circuit. When a time payment system C 5003 is fitted, the connection from pin 7 to connection 2 on the payment system must be disconnected. A bridge must be made in the payment system from connection 3 (operational signal) to connection 2 (transformer). With incorrect connection, connection from pin 7 to connection 2 on the payment system not disconnected, a short circuit will exist at the end of the programme. Check the wiring diagram. Fig. 4 A Open the pre-punched opening/s in the rear casing for the electrical connections as necessary. x Warning! Take care to lay wires such that they cannot be damaged by sharp edges. A Fit the appropriate through-feed parts on the wires. Secure the through-feeds on the rear casing. A Lay the payment system wire to the payment system socket (X1/1). A At the payment system socket (X1/1), cut through the wire bridge 2W14 between pins 3 and 5. Insulate the wire ends. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
85 DTD no A Set the tumble dryer payment system programmable option to Timed operation. A PT 7135 C and PT 7136: For Service Dept. programming mode see Programming mode summary, A PT 5135 C and PT 5136: For Service Dept. programming mode see Programming mode summary, A Fit the payment system on the machine lid, see Fitting payment system on machine lid, Central control via RS 232 interface x PT 7135 C, PT 7136 Danger! Risk of electric shock due to voltage transfer with incorrectly laid data cables. Note The instructions given in the documentation provided with the central control must be followed. Warning! Take care to lay wires such that they cannot be damaged by sharp edges. Take care to lay wires such that they do not touch the drum. A Remove the machine lid , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
86 090-8 DTD no x Fig. 5 Fig. 6 A Unscrew and remove the mains connection box lid. Loosen the cable strain relief. A Pass the data cable through the casing opening for the mains connection cable. Lay the data cable to the RS 232 interface on the power-programme module (ELP). A Connect the data cable plug to the RS 232 interface and secure it with the screws. A Secure the data cable in the strain relief together with the mains connection cable. This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
87 DTD no A At the payment system socket (X1/1), cut either through the wire bridge 1W14 between pins 1 and 2 or the wire bridge 2W14 between pins 3 and 5 as desired. Insulate the wire ends. A At the tumble dryer, set the payment system programmable option to RS 232, see Programming mode summary, , DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
88 DTD no This information should not be duplicated or passed on without Miele approval. All rights reserved , DE_en
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
B/S/H/ Error codes and service programmes PH
1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Online UPS. PowerWalker VFI 1000R/1U
Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.
FT-100 Fire Training Fog Machine User Manual English
FT-100 Fire Training Fog Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual - English Safety Information Please read the following safety information carefully before operating
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
All About. Servicing. Service Tech Hand Book. 2010 Electrolux Home Products Inc. 10200 David Taylor Drive Charlotte, NC 28262
All About Servicing Service Tech Hand Book 2010 Electrolux Home Products Inc. 10200 David Taylor Drive Charlotte, NC 28262 Publication #5995588729 February 2011 Section 1 Basic Information Safe Servicing
Dyeing Programmer DP - 01
Dyeing Programmer DP - 01 Display and Controls. 1) Display: 16/2 alphanumeric display 2) Temperature range: 0 to 150 degree. 3) Resolution: 1 degree. 4) Accuracy: +/- 1 degree. 5) Temperature control setting:
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: The information included in this Splendide Repair Manual may change without notice. Please see our web site www.splendide.com/service/docs.html for updates,
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06
A/C Performance Diagnosis Problem Warm Airflow When the Air Conditioner is On, A/C Not Working, or Poor A/C Performance (dash outlet temperature is too high) Problem Warm Airflow When the Air Conditioner
NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL
NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL [email protected] / www.tuncmatik.com Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3.
COLOR VIDEO DOOR PHONE CDV-71BE/D
COLOR VIDEO DOOR PHONE CDV-71BE/D 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
Technical Information
Date of last update: Oct-11 Ref: D7.8.4/1011/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors... 1
Convection Ovens. BX Classic. Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C. Operator's Manual
Convection Ovens BX Classic Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C Operator's Manual Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU
Automatic Temperature Control Diagnosis and Repair Diagnosis of Automatic A/C Systems The most common automatic A/C system malfunctions tend to be the result of basic air conditioning problems. These problems
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
GSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.
PLP - TERMS AND CONDITIONS
PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia
A/C-HEATER SYSTEM - AUTOMATIC
A/C-HEATER SYSTEM - AUTOMATIC 1995 Volvo 850 1995-96 Auto. A/C-Heater Systems Volvo 850 * PLEASE READ THIS FIRST * WARNING: To avoid injury from accidental air bag deployment, read and carefully follow
MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
1 General information
1 General information 1.1 About this manual This manual describes the installation, function and operation of an integrated solar control system, which is suitable for split pressurized solar heating system.
Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
PANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
REMOTE CONTROL MANUAL
REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read
Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales
Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales SPECIFICATION FOR LAUNDRY EQUIPMENT MAINTENANCE Maintenance Module 32 March 2011 issue This document has been compiled by the Engineering
4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No
6. 6.1 and info (Menu 4) NB are shown in the event of unit faults or irregular operation Check the Current list (Menu 4) for alarm messages and refer to the list of alarms given at the end of these instructions.
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
User Manual. Video Doorphone CDV-1020AQ
User Manual Video Doorphone CDV-1020AQ 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133 Web site : www.commax.com
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
OS 3030. Instruction Manual. Electronic Controllers for Reverse Osmosis Plants. Software version 0004 2.00
OS 3030 Electronic Controllers for Reverse Osmosis Plants Instruction Manual Software version 0004 2.00 Contents Functional Description...1 PRODUCTION phase...1 Standby phase...1 Rinse after production
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE
SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE i Read the instructions Contents I. Package content... 3 II. Performance and properties... 3 III. System design...
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09
0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Thermo Top - Troubleshooting Tree
Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives
DOCUMENT: ECSEQ6-0 EFFECTIVE: 09/23/10 SUPERSEDES: Operational Overview and Controls Guide Two or Three Pump IronHeart Lite with Variable Frequency Drives 6700 Best Friend Road. Norcross, GA 30071. (770)
Water Priming Mode Purge air from plumbing system. How do I solve ER-3 WATER PRIME: TIPS ON FILLING SPA IMPORTANT NOTE WARNING
Water Priming Mode Purge air from plumbing system TIPS ON FILLING SPA Before filling remove spa skirt and be sure that all valves in the plumbing system are fully open to maximise the amount of air that
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
HEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. 2 Inch PowerVent LED Indicator Explanations & Troubleshooting Table
New Robertshaw control valve was introduced in May 2008 as a replacement part. See last page for troubleshooting this replacement part. All voltage inputs are 120V. All electrical connectors are Molex
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com [email protected] TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
Variable Air Volume - VAV
Mode Enable Sensor Options Variable Air Volume - VAV The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during occupied operation. The following options are available:
Electrical Resistance Resistance (R)
Electrical Resistance Resistance (R) Any device in a circuit which converts electrical energy into some other form impedes the current. The device which converts electrical energy to heat energy is termed
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function
Important Safeguards READ ALL INSTRUCTIONS BEFORE USE. Instruction Manual Automatic Dispensing Hot Water Pot with Reboil Function Image of SP-3015 & SP-3815 SP-3015: 3.0L SP-3815: 3.8L SP-3017: 3.0L (Stainless
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
Service Tips Fault Codes
/ / / Fault Codes Service Tips Fault Codes DISHWASHER TEST PROGRAM ERROR CODES (on 2 & 3-digit digital displays): 00 0 No faults 1 Aqua Sensor (Sensotronic) fault 2 Heating system fault (heater, Hi-Limit,
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
2 electrical. electrical. 2010 PulteGroup, Inc. All Rights Reserved.
2 12 2010 PulteGroup, Inc. All Rights Reserved. circuit breakers Circuit breakers protect your home s system from power failure. The wiring in your home is protected by circuit breakers. Circuit breakers,
Table Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.
High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output. Modular Design for Easy, Cost Effective Maintenance. Standardized Interface Allows Interchangeable Control Modules
Instruction Manual for Operating Panel 301 and 302
Instruction Manual for Operating Panel 301 and 30 Edition: 1/006 Edition: 1/006 Contents 1 Introduction and Overview........................ 5 1.1 Panel 301 Controls........................................
GSM Home Alarm System User Manual. http://www.usmartbuy.com
GSM Home Alarm System User Manual http://www.usmartbuy.com 1 1. Factory default Normally, all sensors in the big box have been coded (learnt) to the control host Operation Password: 0000 Long-Distance
Alarm Clock USER GUIDE
Alarm Clock USER GUIDE Jazwares, Inc. 2012 CONTENTS Please read the instructions along with the Alarm Clock carefully before you use it, so that you can operate it conveniently. WELCOME & Warnings Page
Aerona Air Source Heat Pumps
ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
Unit 4: Electricity (Part 2)
Unit 4: Electricity (Part 2) Learning Outcomes Students should be able to: 1. Explain what is meant by power and state its units 2. Discuss the importance of reducing electrical energy wastage 3. State
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
UM-X Field display for continous level sensors
Technical Documentation Field display for continous level sensors 10/2007 Edition: 1 Item No.: 207120 FAFNIR GmbH Bahrenfelder Str. 19 D-22765 Hamburg Telephone: +49 (0)40-39 82 07-0 Fax: +49 (0)40-3 90
sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved
Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section
High Security Heavy Duty Shredders VZ 14.00. Perfect shredding and high performance in DIN security levels 4 and 5
High Security Heavy Duty Shredders Perfect shredding and high performance in DIN security levels 4 and 5 Documentation High Security Heavy Duty Shredders / Page 1of 5 Perfect shredding and high performance.
User Guide Reflow Toaster Oven Controller
User Guide Reflow Toaster Oven Controller Version 1.5-01/10/12 DROTEK Web shop: www.drotek.fr SOMMAIRE 1. Introduction... 3 2. Preparation of THE REFLOW CONTROLLER... 4 2.1. Power supply... 4 2.2. USB
TS1200 Intelligent Lead Free Soldering Station. Operation Manual
TS1200 Intelligent Lead Free Soldering Station Operation Manual Thank you for purchasing an Intelligent Lead Free Soldering Station. It is designed for lead free soldering. Please read this manual before
User Manual Color video door phone
User Manual Color video door phone CDV-70KM Thank you for purchasing COMMAX products. Please carefully read this User s Guide (in particular, precautions for safety) before using a product and follow instructions
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board. This Troubleshooting Guide covers the electric coolant valve and control
BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION