APC by Schneider Electric



Similar documents
Data Center Technology: Physical Infrastructure

The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

APC APPLICATION NOTE #92

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

- White Paper - Data Centre Cooling. Best Practice

AIRAH Presentation April 30 th 2014

Elements of Energy Efficiency in Data Centre Cooling Architecture

APC APPLICATION NOTE #112

POD S in Data Centres. The Frame Group Pty Ltd

Improving Data Center Efficiency with Rack or Row Cooling Devices:

State of the Art Energy Efficient Data Centre Air Conditioning

Re Engineering to a "Green" Data Center, with Measurable ROI

The Next Generation APC by Schneider Electric InfraStruxure

Airflow Simulation Solves Data Centre Cooling Problem

StruxureWare TM Data Center Operation

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

An Improved Architecture for High-Efficiency, High-Density Data Centers

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

An Introduction to Cold Aisle Containment Systems in the Data Centre

How To Power And Cool A Data Center

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

National Grid Your Partner in Energy Solutions

How Row-based Data Center Cooling Works

Sovereign. The made to measure data centre

Case Study Nottingham Trent University

Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

Large Data Center, Total system for efficiency. WFES January 2010

Blade Server & Data Room Cooling Specialists

Data Center Equipment Power Trends

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

European Code of Conduct for Data Centre. Presentation of the Awards 2016

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Increasing Energ y Efficiency In Data Centers

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Technical Systems. Helen Bedford

abstract about the GREEn GRiD

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

InfraStruxure Data Centre Management Software. Holistic open standards integrated data centre management solution.

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Engineers Ireland Cost of Data Centre Operation/Ownership. 14 th March, 2013 Robert Bath Digital Realty

The Pros and Cons of Modular Systems

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Data Center Components Overview

BCS Foundation Certificate in Data Centre Infrastructure Syllabus. Version 1.2 March 2015

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

In Row Cooling Options for High Density IT Applications

IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT

Creating Order from Chaos in Data Centers and Server Rooms

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

11 Top Tips for Energy-Efficient Data Center Design and Operation

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Raised Floor Data Centers Prepared for the Future

T:

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

CANNON T4 MODULAR DATA CENTRE HALLS

Solutions for Small to Medium Data Centers

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Strategies for Deploying Blade Servers in Existing Data Centers

ICT and the Green Data Centre

Energy Impact of Increased Server Inlet Temperature

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

DATA CENTER SOLUTIONS GUIDE

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Essential NCPI Management Requirements for Next Generation Data Centers

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Creating Order from Chaos in Data Centers and Server Rooms

Future-Proof the Banking and Finance Data Center

BICSInews. plus. july/august Industrial-grade Infrastructure. + I Say Bonding, You Say Grounding + Data Center Containment.

The Different Types of Air Conditioning Equipment for IT Environments

How to Build a Data Centre Cooling Budget. Ian Cathcart

THE WORLD S MOST EFFICIENT DATA CENTER

Design Best Practices for Data Centers

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER

FEAR Model - Review Cell Module Block

Transcription:

APC by Schneider Electric Energy Efficiency - The Green Power Solution James Taylor Business Development manager, UK

APC by Schneider Electric The Efficient Enterprise Components Close Coupled Cooling Hot Air Containment Capacity Management

A Heritage of leadership, experience and innovation APC was acquired by Schneider Electric in 2007 MGE UPS Systems, another division of Schneider Electric, merged with APC Together they represent the Critical Power & Cooling Services Business Unit of Schneider Electric

APC by Schneider Electric delivers unmatched customer benefits Industry s most comprehensive product & solutions Only integrated power, cooling, and management solution Industry s broadest service organization Industry s largest R&D investment The choice of IT andelectrical customers and channels

A sustainable innovation effort Global R&D centers supporting global and local platforms Nearly1000 R&D employees operating worldwide Industry leading investment in R&D Innovating services, solutions, & software Power, Cooling, Data Center Design and Management expertise

Preferred by industry experts For the past seven years, APC-MGE has consistently increased its revenue share and mindshare within the data center market. Their success is a combination of customer-centric power and cooling solutions and the execution of successful strategic industry alliances. By advancing the progress of data center solutions in efficiency, design and scalability, while continuing to exceed the latest application requirements, they are a true leader and a worthy recipient of the 2007 Frost & Sullivan Data Center Solutions Company of the Year Award.

While developing leading alliances and partnerships The Data Center and IT Ecosystem Unique, collaborative offer development (margin) Channel synchronicity Demand Creation Associations and Standards Boards Thought Leadership/Trusted Advisor Vision and strategy alignment Governments Thought Leadership/Trusted Advisor Vision and strategy alignment Utilities Energy Efficiency architectural rebate qualification for end-users Vision and strategy alignment

APC by Schneider Electric The Efficient Enterprise

What is it and why you need it Today s Server rooms and DC are designed and built using multiple, disparate vendors which gives you the client..unique solutions. Standardized Modular Scaleable Integrated Repeatable Understandable Uniqueness is for art NOT for infrastructure!

Introducing the revolutionary architecture.. The Efficient Enterprise integrates Power, Cooling and Management components to work seamlessly, automatically, to drive down CAPEX & OPEX and gives you, the business more power, more control and more Network Availability. The 4 C s to optimise DC efficiency four principles to ensure a more predictable, waste free DC environment that saves energy, boosts availability and positions you for the future growth; 1. Components right sized 2. Close coupling the cooling to the heat source 3. Containment of hot air 4. Capacity management

The 4 C s 1 Components right sized 3 Containment of hot air 2 Close-coupled cooling 4 Capacity management

Right size the components Growth is good, but its unpredictable, so companies oversize their requirements, i.e. power/cooling Hot swap Intelligent Module This overkill is a huge waste of resources Our scalable, modular architecture allows you to power & cool only what you need, when you need it Pay as you grow! Hot swap Power Module, pf 1 Hot swap Battery Module Hot swap components reduces MTTR and therefore increases network availability.

Closed Couple Cooling Hot air will always take the path of least resistance! Heat captured and rejected to chilled water or refrigerant The innovative InRow architecture reduces the distance between the heat source and the heat removal system bringing the cooling right to where the heat is generated Cold air delivered to cold aisle More control over airflow and therefore prevents the hot exhaust gas from mixing with the ambient air or re circulating to sensitive IT equipment Hot aisle air enters from rear

Closed Couple Cooling Central Air Handling Unit (CAHU) Computer Room Air Handler (CRAH) In-row Air Handler (IRAH) InRow Cooling is up to 30% more efficient than traditional cooling methodologies.

Hot Air Containment Delivering cold air to where it s required is not often the problem but getting rid of hot air is! When the hot air exhaust generated by high density applications mixes with the cooler ambient air, the airflow around the DC becomes unpredictable and localised hot spots are created. Only a containment design managed by computer can deliver The legacy approach of adding more precisely cooling capacity the right and lowering cooling the to precisely the right load at precisely the temperature does not solve problem, which right is one of time, air distribution thereby ensuring lowest carbon footprint. The Hot Air Containment System (HACS) ensures proper airflow by completely separating supply and return air paths. The HACS seals off the hot air and captures it at its source and therefore prevents hot and cold air mixing. Airflow paths become well defined and predictable!

Capacity Management A crystal ball for IT needs! Enterprise Management Software applications that gives you insight into your DC over its entire life cycle. One powerful platform allows you to optimize resources, plan future needs accurately and incorporate changes smoothly Manages all IT physical infrastructure devices including: Servers Cooling UPS s PDU s Rack s Network Gear Storage APC Capacity Manager tool received 2007 Data Center Product of the Year Gold Award from Searchdatacenter.com in the capacity and power management tools category

Capacity Management Mobile Device Moves Eliminate manual data entry and reduce errors; adding, moving or retiring devices whilst on the move Mobile Synchronization Keep your physical data center synchronized with your data center management tool

Capacity Management Rack Rack equipment equipment planning planning Create Create work work orders orders and and automatically automatically generate generate tasks tasks to to carry carry out out changes changes to to IT IT equipment. equipment. For For users users of of Capacity Capacity Manager Manager Mobile Mobile Search Search Quickly Quickly locate locate bar-coded bar-coded assets assets via via the the search search functionality functionality using using the the Symbol Symbol MC50 MC50 Digital Digital Assistant Assistant Store Store room room Keep Keep track track of of new new devices devices from from arrival arrival on on site site in in the the virtual virtual store store room room Rack Rack elevations elevations Easy Easy to to use use rack rack front front view view enables enables accurate accurate and and detailed detailed representation representation of of where where equipment equipment is is located located in in the the racks racks

Capacity Management Custom Custom Devices Devices Quickly Quickly customize customize catalog catalog devices devices to to your your specifications specifications in in just just 2 clicks, clicks, amending amending data data points points such such as as power power requirements requirements Device Device catalog catalog Utilize Utilize the the extensive extensive library library of of physical physical infrastructure infrastructure and and IT IT devices devices from from leading leading vendors vendors Floor Floor layout layout View View an an accurate accurate representation representation of of your your data data center center through through the the easy easy to to use use graphical graphical floor floor layout layout and and birds birds eye eye view view

Thank you APC-MGE, the 2007 Global Data Center Solutions Company of the Year Frost & Sullivan