Push Buttons and Operator Interface Specifier s Guide MAGELiS Operator Terminals File 900 CONTENTS Schneider Electric Brands Description Page Product Description................................................ 49 XBTH/P/E/HM/PM Display Units and Terminals........................... 4 XBTH Display Units with Line Alphanumeric Screen...................... XBTP Terminals with Line Alphanumeric Screen........................ 8 XBTE Terminals with or 4 Line Alphanumeric Screen..................... 0 XBTHM/PM Display Units with 8 Line Matrix Screen....................... XBTF Terminals with Graphic Screen................................... 4 Development Software.............................................. 7 Separate Parts.................................................... 7 XBTF Bus and Network Connections................................... 78 Wiring Diagrams................................................... 80 Dimensions....................................................... 9 Declaration of Conformity............................................ 3
48 999-000 Schneider Electric All Rights Reserved /00
Product Description General The MAGELiS operator terminals come with the following features: Alphanumeric LCD or fluorescent displays - or 0-inch size Graphical matrix display Monochrome or color screen Touch sensitive types Configuration software based on the Windows programming environment All terminals programmable using the same software package and the same configuration procedure Graphics terminals using a symbols library that allows the programmer to develop customized, animated screens Many different protocols supported that allow communication with a wide variety of programmable controllers NOTE: A bullet ( ) in the catalog number denotes a character that can vary. /00 999-000 Schneider Electric All Rights Reserved 49
Product Description Terminals Display Units with Alphanumeric Screen Terminals with Alphanumeric Screen Display Units with Matrix Screen Display Type Fluorescent green matrix ( x 7 pixels), height 0. in. ( mm) or Back-lit LCD ( x 7 pixels), height 0.3 in. (9 mm) Fluorescent green matrix ( x 7 pixels), height 0. in. ( mm) or Back-lit LCD ( x 7 pixels), height 0. in. ( mm) Back-lit monochrome matrix LCD (40 x 4 pixels) height 0. or 0.4 in. (.3 or 0. mm) Capacity lines of 0 characters or 4 lines of 40 characters 4 to 8 lines of 0 to 40 characters Data Entry Display only or Via keypad with 4 function keys or service keys Via keypad with 8 function keys 9 service keys or function keys 0 service keys numeric keys Via keypad with 4 function keys 0 service keys alphanumeric keys Memory Capacity Application 8 KB/ KB Flash EEPROM KB Flash EEPROM 384 KB Flash EEPROM Extension via PCMCIA Type II Functions Maximum Number of Pages Variables per Page 0 Representation of the Variables 00/00 application pages 8/ alarm pages Alphanumeric 400 application pages alarm pages Recipes Curves Alarm Logs Dependent on the model 800 applications pages alarm pages Display only or Via keypad with 4 function keys or service keys 00 application pages alarm pages Alphanumeric, bargraph, gauge Real-Time Clock Access to the PLC real-time clock Built-in Access to the PLC real-time clock Alarm Relay No Yes No Communication Asynchronous Serial Port Downloadable Protocols RS 3 C / RS 48 / RS 4 UNI-TELWAY, MODBUS, AEG and for Allen Bradley, GE Fanuc, Omron, Siemens brand PLCs Buses and Networks AS-i with module at. intervals AS-i with module at. intervals Printer Port Development Software Operating Systems RS 3 C asynchronous serial link (dependent on the model) XBTL000/L003/L004 (under Windows 3. or Windows 9) MAGELiS Type of Terminal XBTH XBTP XBTE XBTHM Page 8 0 XBTL003/L004 (under Windows 9 and Windows NT 4.0) 0 999-000 Schneider Electric All Rights Reserved /00
Product Description Terminals Display Units with matrix screen Terminals with graphic screen Display Type Capacity Data Entry Back-lit monochrome matrix LCD (40 x 4 pixels) height 0. or 0.4 in. (.3 or 0. mm) 4 to 8 lines of 0 to 40 characters Via keypad with function keys 0 service keys numeric keys 4 dynamic function keys Back-lit monochrome LCD (30 x 40 pixels) or Color LCD STN with touch-sensitive screen (30 x 40 pixels) Back-lit monochrome LCD (40 x 480 pixels) or Back-lit color TFT LCD (40 x 480 pixels).7 in. (4 mm) 9. in. (4 mm) monochrome (XBTF0 only) 0.4 in. (4 mm) color Via touch-sensitive screen with 4 touch-sensitive keys (XBTFC) Touch n Click Via keypad with 0 static function keys 8 dynamic function keys service keys alphanumeric keys Via touch-sensitive screen with 8,, or touch-sensitive keys () (XBTFC) Touch n Click Via keypad with static function keys 0 dynamic function keys service keys alphanumeric keys Memory Capacity Application KB Flash EEPROM 8 MB Flash EEPROM (using Type II PCMCIA card) Extension via PCMCIA Type II Functions Maximum Number of Pages 400 application pages alarm pages printout form pages () 8 MB or MB Variables per Page 0 4 Representation of the Variables Alphanumeric 0 to 40 application, alarm, help, and printout form pages, depending on the memory card used ( alarms max) Alphanumeric, bitmap, bargraph, gauge, potentiometer, selector Recipes Maximum records with maximum 000 values Curves Alarm Logs Dependent on the model Yes Real-time Clock Access to the PLC real-time clock Alarm Relay No Yes Communication Asynchronous Serial Port Downloadable Protocols RS 3 C / RS 48 / RS 4 UNI-TELWAY, MODBUS, AEG and for Allen Bradley, GE Fanuc, Omron, and Siemens brand PLCs Buses and Networks AS-i with module MODBUS Plus, FIPIO /FIPWAY with optional Type III PCMCIA card Printer Port Development Software Operating Systems RS 3 C asynchronous serial link (dependent on the model) XBTL000/L003/L004 MAGELiS XBTL003/L004 (under Windows 9 and NT 4.x) Type of Terminal XBTPM XBTF0/F03/FC XBTF0/F03/FC Page 3 8, 70 8, 70 () Dependent on the model. 30 to 300 application, alarm, help, and printout form pages, depending on memory card used ( alarms max) /00 999-000 Schneider Electric All Rights Reserved
Product Description Architectures, connections to control systems MAGELiS operator dialogue terminals communicate with control system equipment: Via serial link Via fieldbus In network architectures Point-to-point or multidrop connection with the PLC via serial link Quantum All terminals incorporate an RS 3 C, RS 4/48 asynchronous serial link as standard. Nano The use of a UNI-TELWAY, MODBUS, or KS protocol means that communication can be set up easily with Schneider Electric PLCs: TSX, MODICON, April, or A-Line. XBT-HM Micro XBT-F MODBUS Third-party protocols provide connection to PLCs offered by the main market suppliers: DF, DH48 for Allen Bradley PLC/SLC00 PLCs SNPX for General Electric Series 90 PLCs Sysway for Omron C00 PLCs AS/394R, MPI/PPI for Siemens Simatic S/S7 PLCs UNI-TELWAY XBT-P Connection to PLCs via fieldbus The addition of a Type III PCMCIA communication card to XBTF terminals with graphic screen enables connection to various industrial networks: FIPIO Bus TBX TBX Premium FIPIO MODBUS Plus XBTF terminals with graphic screen use the bus master PLC to provide operator dialogue and interactive control of various devices connected on the bus. Several terminals with graphic screen can be connected on the same bus. ATV- XBT-F 999-000 Schneider Electric All Rights Reserved /00
Product Description Connection to network architectures The addition of a Type III PCMCIA communication card to XBTF terminals with graphic screen means that they can be integrated into single or multiple network architectures: FIPWAY network MODBUS Plus network XBT-F MODBUS Plus Premium Micro MOMENTUM Quantum FIPIO Bus XBT-F ATV- /00 999-000 Schneider Electric All Rights Reserved 3
XBTH/P/E/HM/PM Display Units and Terminals General Presentation XBTH/P/E display units and terminals with alphanumeric screen are used to represent messages and variables. Various keys can be used to modify variables, control the device, or browse in a dialogue application. XBTH XBTP XBTE XBTHM/PM terminals with matrix screen can also be used to display bitmap images and animated bar chart and gauge objects. XBTHM XBTPM Operation All the MAGELiS display units and terminals with alphanumeric and matrix screens have the same user interface: function keys, service keys, and numeric or alphanumeric keys. Configuration MAGELiS display units and terminals can be configured using the same XBTL00 software in a Windows environment. For terminals with an alphanumeric screen, XBTL00 software employs pages. Each page can be viewed in its entirety. Selecting a line of text shows what will appear on the product screen (two to four lines, depending on the model). For XBTHM terminals with a matrix screen, XBTL00 software offers up to 8 lines of 40 characters, and animated bar chart and gauge objects. Communication XBTH/P/E/HM/PM terminals communicate with PLCs via an integrated point-to-point or multidrop serial link. XBTH PLC The communication protocols used are those of Schneider PLCs as well as those of the other main market suppliers. Functions Depending on the model, XBTH/P/E/HM/PM display units and terminals have function keys and service keys on the front panel. Function Keys Function keys are defined for the whole application. They can be used for accessing a page, pulse control, and toggle set/reset. Service Keys Service keys are the arrow keys and the control keys combined. Service keys are used for modifying the parameters of the control system. 4 999 000 Schneider Electric All Rights Reserved /00
The control keys are used to perform the following actions: MAGELiS Operator Terminals XBTH/P/E/HM/PM Display Units and Terminals ENTER MOD ESC SHIFT MENU HOME SYST ALARM PRINT Confirm a selection or entry, acknowledge an alarm Change to the mode for entering pages, passwords, fields or graphic objects Cancel an entry, suspend or stop a current action Access the second of the dual key functions Access a menu containing the operating functions Return to the entry point of the current menu Example: return to the first page of the application Access the confidential mode, which contains the implementation functions View the alarms Print The arrow keys are used to: Change page within a menu Move within a page Select the value of a digit Select a value from a list of choices When used with the SHIFT key, increment or decrement the value of a variable field Description XBTH/P/E/HM/PM display units and terminals include: 4 3 On the front panel:. A communication monitoring indicator lamp. A keypad activity indicator lamp (dependent on the model) 3. Fluorescent or LCD back-lit display 4. Function keys with indicator lamp and reusable labels. Service keys with indicator lamp. Twelve numeric keys (for XBTP0 ) Twelve alphanumeric keys [0 to 9, (+/ ), (.)] associated with three alphabetical access keys (A to Z) for XBTE On the rear:. A plug-in terminal block for 4 Vdc power supply and a connection for the alarm relay (dependent on the model). A female -pin SUB-D connector for connection to PLCs, FTX configuration terminals, or PC compatibles 3. A male 9-pin SUB-D connector for the printer connection (dependent on the model) 3 /00 999 000 Schneider Electric All Rights Reserved
XBTH Display Units with Line Alphanumeric Screen Selection XBTH0 00 Display Units with Lines of 0 Characters (Fluorescent) Downloadable Exchange Protocol Function Number of Keys Service Supply Voltage (VDC) Language Version Number No Printer Port, No Log 4 Multilingual XBTH0000.3 (0.) See page 7 4 4 Multilingual XBTH000.3 (0.) 4 Multilingual XBTH000.3 (0.) With Printer Port and Log See page 7 4 Multilingual XBTH00.3 (0.) Display Units with Lines of 0 Characters (LCD) Downloadable Exchange Protocol No Printer Port, No Log UNI-TELWAY See page 7 Function Number of Keys Service Supply Voltage (VDC) 4 and via terminal socket on the TSX Nano/Micro/Premium PLC Language Version Number Multilingual XBTH800.3 (0.) XBTH0 0 XBTH00 00 Display Units with Lines of 0 Characters (Back-Lit LCD) Downloadable Exchange Protocol No Printer Port, No Log See page 7 Function Number of Keys Service Alphanumeric Alphanumeric Alphanumeric Supply Voltage (VDC) Language Version Number 4 Multilingual XBTH0000.3 (0.) 4 4 Multilingual XBTH000.3 (0.) 4 Multilingual XBTH000.3 (0.) Separate Parts Description Use Number Development Software Under Windows 3. or 9, for downloading the application and protocols See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Documentation Description Format Included in the Product MAGELiS User s Manual A Bound (48 x 0 mm, approx. x 8. in) Add the following suffixes EN: English, FR: French, DE: German, ES: Spanish, T: Italian. Number XBTL003 and XBTL004 XBTX000 0.4 (0.) 999 000 Schneider Electric All Rights Reserved /00
XBTH Display Units with Line Alphanumeric Screen Specifications Type of Display Unit XBTH0 0 (Fluorescent) XBTH800 (LCD) XBTH0 00 (Back-Lit LCD) Environment Conforming to Standards IEC 3-, IEC 008--, IEC 008--7, EN 3-, UL 08, CSA C- No. 4 Product Certifications CE, UL, CSA, UL E48, CCN: NRAQ, CSA LR 44087, Class 0 Temperature Operation +3 to + F (0 to +0 C) Storage 40 to +8 F ( 40 to +70 C) 4 to +40 F ( 0 to +0 C) Degree of Protection IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with 4 or screws (supplied), pressure-mounted on a panel of thickness 0.04 0.4 in. ( mm) Material Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) XBTH00 00 XBTH0 00 Keys No keys 4 function keys service key Electrical Characteristics Display Unit Power Supply XBTH0 0 service keys Fluorescent green matrix characters ( x 7 pixels) lines of 0 characters, height 0. in. ( mm) XBTH800 XBTH00 00 XBTH0 00 service keys No key 4 function keys service key LCD ( x 7 pixels) lines of 0 characters, height 0.3 in. (9 mm) Voltage 4 Vdc not isolated During configuration: 4 Vdc not isolated During operation: Vdc via TSX Nano/Micro/Premium PLC terminal port Voltage Limits 8 30 V Ripple % maximum Consumption 0 W. W 0 W Operating Characteristics Signaling Memory Log Function Transmission (asynchronous serial link) Downloadable Protocol Real-Time Clock Printer Port (asynchronous serial link) XBTH00 00 XBTH0 00 XBTH0 0 XBTH80 Back-lit LCD ( x 7 pixels) lines of 0 characters, height 0.3 in. (9 mm) 4 Vdc not isolated XBTH00 00 XBTH0 00 XBTH0 00 service keys XBTH0 00 LED LEDs 4 LEDs LED LEDs 4 LEDs 8 KB Flash EEPROM, KB (XBTH00) 00 application pages approximately ( lines per page) available alarm pages ( lines per page) Permits storage of alarm pages (XBTH00) 8 KB Flash EEPROM 00 application pages approximately ( lines per page) 8 available alarm pages ( lines per page) 8 KB Flash EEPROM, KB (XBTH000) 00 application pages approximately ( lines per page) available alarm pages ( lines per page) RS 3 C / RS 8 / RS 4 RS 3 C / RS 48 RS 3 C / RS 48 / RS 4 Multiple (see pages 4 and 7) Access to the PLC real-time clock UNI-TELWAY (see pages 4 and 7) Multiple (see page 4 and 7) RS 3 C (XBTH00) Connection Power Supply Plug-in terminal block 3 screw terminals, 3/4 (.08 mm) pitch Maximum clamping capacity: # AWG (. mm ) Serial Port Female -pin SUB-D connector Printer Port Male 9-pin SUB-D connector /00 999 000 Schneider Electric All Rights Reserved 7
XBTP Terminals with Line Alphanumeric Screen Selection XBTP0 00 Terminals with Lines of 0 Characters (Fluorescent) Downloadable Exchange Protocol Function Number of Keys Service Supply Voltage (VDC) Language Version Number No Printer Port, No Log 8 9 4 Multilingual XBTP000.8 (0.8) See page 7 0 4 Multilingual XBTP000.8 (0.8) With Printer Port and Log See page 7 0 4 Multilingual XBTP00.8 (0.8) XBTP0 0 Terminals with Lines of 0 Characters (Back-Lit LCD) Downloadable Exchange Protocol Function Number of Keys Service Alphanumeric Alphanumeric Supply Voltage (VDC) Language Version Number No Printer Port, No Log 8 9 4 Multilingual XBTP000.8 (0.8) See page 7 0 4 Multilingual XBTP000.8 (0.8) With Printer Port and Log See page 7 0 4 Multilingual XBTP00.8 (0.8) Separate Parts Description Use Number Development Software Under Windows 3. or 9, for downloading the application and protocols See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Documentation Description Format Included in the Product MAGELiS User s Manual A Bound (48 x 0 mm, approx. x 8. in) Add the following suffixes EN: English, FR: French, DE: German, ES: Spanish, T: Italian. Number XBTL003 and XBTL004 XBTX000 0.4 (0.) 8 999 000 Schneider Electric All Rights Reserved /00
XBTP Terminals with Line Alphanumeric Screen Specifications Type of Terminal XBTP0 0 (Fluorescent) XBTP0 0 (Back-Lit LCD) Environment Conforming to Standards IEC 3-, IEC 008--, IEC 008--7, EN 3-, UL 08, CSA C- No. 4 Product Certifications CE, UL, CSA, UL E48, CCN: NRAQ, CSA LR 44087, Class 0 Temperature Operation +3 to + F (0 to +0 C) Storage 40 to +8 F ( 40 to +70 C) 4 to +40 F ( 0 to +0 C) Degree of Protection IP, conforming to IEC 009, NEMA Type 4, UL Type 4 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with 4 or screws (supplied), pressure-mounted on a panel of thickness 0.04 0.4 in. ( mm) Material Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) XBTP000 XBTP0 0 XBTP000 XBTP0 0 Keys Electrical Characteristics Display Unit Power Voltage Supply Voltage Limits Ripple Consumption Operating Characteristics Signaling Memory 8 function keys 9 service keys function keys 0 service keys numeric keys Fluorescent green matrix characters ( x 7 pixels) lines of 0 characters, height 0.0 in. ( mm) 4 Vdc not isolated 8 30 V % maximum 0 W 8 function keys 9 service keys function keys 0 service keys numeric keys Back-lit LCD ( x 7 pixels) lines of 0 characters, height 0.3 in. (9 mm) XBTP000 XBTP0 0 XBTP000 XBTP0 0 7 LEDs LEDs 7 LEDs LEDs KB Flash EEPROM 400 application pages approximately ( lines per page) available alarm pages ( lines per page) Log Function Permits storage of alarm pages (XBTP00) Permits storage of alarm pages (XBTP00) Transmission (asynchronous serial link) RS 3 C / RS 48 / RS 4 Downloadable Protocol Multiple (see pages 4 and 7) Real-Time Clock Printer Port (asynchronous serial link) Access to the PLC real-time clock RS 3 C (XBTP00) Connection Power Supply Plug-in terminal block 3 screw terminals, 3/4 (.08 mm) pitch Maximum clamping capacity: # AWG (. mm ) Serial Port Female -pin SUB-D connector Printer Port Male 9-pin SUB-D connector RS 3 C (XBTP00) /00 999 000 Schneider Electric All Rights Reserved 9
XBTE Terminals with or 4 Line Alphanumeric Screen Selection Terminals with Lines of 40 Characters (Fluorescent) Downloadable Exchange Protocol Function Number of Keys Service Supply Voltage (VDC) Language Version Number No Printer Port, No Log See page 7 4 0 4 Multilingual XBTE0400. (.0) With Printer Port and Log See page 7 4 0 4 Multilingual XBTE040. (.0) XBTE04 0 Terminals with 4 Lines of 40 Characters (Fluorescent) Downloadable Exchange Protocol Function Number of Keys Service Supply Voltage (VDC) Language Version Number No Printer Port, No Log See page 7 4 0 4 Multilingual XBTE000. (.0) With Printer Port and Log See page 7 4 0 4 Multilingual XBTE00. (.0) XBTE0 0 Terminals with Lines of 40 Characters (Back-Lit LCD) Downloadable Exchange Protocol Function Number of Keys Service Supply Voltage (VDC) Language Version Number No Printer Port, No Log See page 7 4 0 4 Multilingual XBTE0300. (.0) With Printer Port and Log See page 7 4 0 4 Multilingual XBTE030. (.0) XBTE03 0 Terminals with 4 Lines of 40 Characters (Back-Lit LCD) Downloadable Exchange Protocol Function Number of Keys Service Alphanumeric Alphanumeric Alphanumeric Alphanumeric Supply Voltage (VDC) Language Version Number No Printer Port, No Log See page 7 4 0 4 Multilingual XBTE000. (.0) With Printer Port and Log See page 7 4 0 4 Multilingual XBTE00. (.0) XBTE0 0 Separate Parts Description Use Number Development Software Under Windows 3. or 9, for downloading the application and protocols See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Documentation Description Format Included in Product MAGELiS User s Manual A Bound (48 x 0 mm, approx. x 8. in) Add the following suffixes EN: English, FR: French, DE: German, ES: Spanish, T: Italian. Number XBTL003 and XBTL004 XBTX000 0.4 (0.) 0 999 000 Schneider Electric All Rights Reserved /00
XBTE Terminals with or 4 Line Alphanumeric Screen Specifications Type of Terminal XBTE04 0/XBTE0 0 (Fluorescent) XBTE03 0/XBTE0 0 (Back-Lit LCD) Environment Conforming to Standards IEC 3-, IEC 008--, IEC 008--7, EN 3-, UL 08, CSA C- No. 4 Product Certifications CE, UL, CSA, UL E48, CCN: NRAQ, CSA LR 44087, Class 0 Temperature Operation +3 to + F (0 to +0 C) Storage 40 to +8 F ( 40 to +70 C) 4 to +40 F ( 0 to +0 C) Degree of Protection IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with 4 or screws (supplied), pressure-mounted on a panel of thickness 0.04 0.4 in. ( mm) Material Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) Keys Function 4 Service 0 Alphanumeric Electrical Characteristics Display Unit Fluorescent green matrix characters ( x 7 pixels) Back-lit LCD ( x 7 pixels) XBTE04 0 XBTE0 0 XBTE03 0 XBTE0 0 lines of 40 characters, height 0.0 in. ( mm) 4 lines of 40 characters, height 0.0 in. ( mm) Power Voltage 4 Vdc not isolated Supply Voltage Limits 8 30 V Ripple % maximum Consumption 0 W 0 W Operating Characteristics Signaling 33 LEDs + buzzer Memory 384 KB Flash EEPROM 800 application pages approximately ( lines per page) available alarm pages ( lines per page) 400 application pages approximately (4 lines per page) 8 available alarm pages (4 lines per page) Log Function Transmission (asynchronous serial link) Permits storage of alarm pages RS 3 C / RS 48 / RS 4 Downloadable Protocol Multiple (see pages 4 and 7) lines of 40 characters, height 0.0 in. ( mm) 4 lines of 40 characters, height 0.0 in. ( mm) Real-Time Clock Printer Port (asynchronous serial link) Alarm Relay Connection Power Supply and Alarm Relay Serial Port Printer Port Access to the PLC real-time clock RS 3 C (XBTE040 and XBTE00) N.O. contact min. ma/ Vdc max. 0. A/4 Vdc Plug-in terminal block 3 screw terminals, 3/4 (.08 mm) pitch Maximum clamping capacity: # AWG (. mm ) Female -pin SUB-D connector Male 9-pin SUB-D connector RS 3 C (XBTE030 and XBTE00) /00 999 000 Schneider Electric All Rights Reserved
XBTHM/PM Display Units with 8 Line Matrix Screen Selection XBTHM00700 XBTHM0700 Display Units with 8 Line Matrix Screen of 40 Characters (Back-Lit LCD) Downloadable Exchange Protocol See page 7 Function Number of Keys Service Alphanumeric Supply Voltage (VDC) Language Version Number 4 Multilingual XBTHM00700.3 (0.) No Printer Port, No Log 4 4 Multilingual XBTHM0700.3 (0.) 4 Multilingual XBTHM0700.3 (0.) Power Suite 4 Multilingual XBTHM0700A8.3 (0.) With Printer Port and Log 4 Multilingual XBTHM070.3 (0.) Terminal specifically for controlling up to eight ATV8/ATV8 variable-speed drive controllers. Separate Parts Description Use Number Development Software Under Windows 9 or NT 4.0, for downloading the application and protocols See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Documentation Description Format Included in Product Number MAGELiS User s Manual A Bound (48 x 0 mm, approx. x 8. in) XBTL003 and XBTL004 XBTX000 0.4 (0.) Add the following suffixes EN: English, FR: French, DE: German, ES: Spanish, T: Italian. XBTHM07 0 Specifications Type of Display Unit XBTHM0 7 0 (Back-Lit LCD) Environment Conforming to Standards IEC 3-, IEC 008--, IEC 008--7, EN 3-, UL 08, CSA C- No. 4 Product Certifications CE, UL, CSA, UL E48, CCN: NRAQ, CSA LR 44087, Class 0 Temperature Operation +3 to + F (0 to +0 C) Storage 4 to +40 F ( 0 to +0 C) Degree of Protection IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with spring clips (supplied), pressure-mounted on a panel of thickness 0.04 0.4 in. ( mm) Material Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) XBTHM00700 XBTHM0700 XBTHM07 0 Keys No keys 4 function keys + service key service keys Electrical Characteristics Display Unit Back-lit LCD (40 x 4 pixels) 8 lines of 40 character, height 0. in. (.3 mm), single size 4 lines of 0 characters height 0.4 in. (0. mm), double height, double width Power Supply Voltage 4 Vdc not isolated Voltage Limits 8 30 V Ripple % maximum Consumption W Operating Characteristics XBTHM00700 XBTHM0700 XBTHM07 0 Signaling LED LEDs 4 LEDs Memory 384 KB Flash EEPROM 00 application pages approximately (8 lines per page), available alarm pages ( lines per page) Transmission (asynchronous serial link) RS 3 C / RS 48 / RS 4 Downloadable Protocol Multiple (see pages 4 and 7) Real-Time Clock Access to the PLC real-time clock Printer Port (asynchronous serial link) RS 3 C (XBTHM070) Connection Power Supply Plug-in terminal block 3 screw terminals, 3/4 (.08 mm) pitch Maximum clamping capacity: # AWG (. mm ) Serial Port Female -pin SUB-D connector Printer Port Male 9-pin SUB-D connector 999 000 Schneider Electric All Rights Reserved /00
XBTHM/PM Display Units with 8 Line Matrix Screen Selection XBTPM Terminals with 8 Line Matrix Screen of 40 Characters (Back-Lit LCD) Downloadable Exchange Protocol No Printer Port See page 7 Function Number of Keys Dynamic Function Service Alphanumeric Supply Voltage (VDC) Language Version Number 4 0 4 Multilingual XBTPM0700.3 (0.) With Printer Port See page 7 4 0 4 Multilingual XBTPM070.3 (0.) Separate Parts Description Use Number Development Software Under Windows 9 or NT 4.0, for downloading the application and protocols See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Documentation Description Format Included in the Product Number MAGELiS User's Manual A Bound (48 x 0 mm, approx. x 8. in) XBTL003 and XBTL004 XBTX000 0.4 (0.) Add the following suffixes EN: English, FR: French, DE: German, ES: Spanish, T: Italian. Specifications Type of Display Unit XBTPM07 0 (Back-lit matrix LCD) Environment Conforming to Standards IEC 3-, IEC 008--, IEC 008--7, EN 3-, UL 08, CSA C- No. 4 Product Certifications CE, UL, CSA, UL E48; CCN: NRAQ, CSA LR 44087; Class 0, UL FM Class Division Temperature Operation +3 to + F (0 to +0 C) Storage 4 to +40 F ( 0 to +0 C) Degree of Protection IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with spring clips (supplied), pressure-mounted on a panel of thickness 0.0 0.4 in. (. mm) Material Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) Keys Function static, 4 dynamic Service Numeric Electrical Characteristics Display Unit Back-lit LCD (40 x 4 pixels) 8 lines of 40 characters, height 0. in. (.3 mm), single size 4 lines of 0 characters, height 0.4 in. (0. mm), double height, double width Power Supply Voltage 4 Vdc, not isolated Voltage Limits 8 30 V Ripple % maximum Consumption W Operating Characteristics Signaling LEDs Memory KB Flash EEPROM 400 application pages approximately available alarm pages depending on distribution Transmission (asynchronous serial link) RS 3 C / RS 48 / RS 4 Downloadable Protocol Multiple (see pages 4 and 7) Real-Time Clock Access to the PLC real-time clock Printer Port (asynchronous serial link) RS 3 C (XBTPM070) Connection Power Supply Plug-in terminal block 3 screw terminals 3/4 (.08 mm) pitch Maximum clamping capacity: # AWG (. mm ) Serial Port -pin SUB-D connector Printer Port 9-pin SUB-D connector /00 999 000 Schneider Electric All Rights Reserved 3
XBTF Terminals with Graphic Screen General Presentation Graphic screen operator dialogue terminals are available with or 0 in. (7 or 4 mm) screens, in monochrome or color, with a keypad or a touchsensitive screen. XBTF graphic screen terminals are specially designed for operator dialogue graphic functions. XBTF0/F03 XBTF0/F03 XBTFC0/F04 XBTFC0/F08 Operation All MAGELiS graphic screen terminals have the same user interface: static and dynamic function keys, service keys, alphanumeric keys. Configuration MAGELiS graphic screen terminals can be configured using the same XBTL00 software in a Windows environment. XBTL00 software provides graphic screen terminals with a library of animated graphic objects such as bargraphs, volume indicator meters, selectors, potentiometers, and trending curves. The variable for animating an object can be selected directly from a list of symbols given by the PL7 or CONCEPT TM software. The application program for the graphic terminals is stored on a PCMCIA memory card. Communication XBTF PLC XBTF graphic screen terminals communicate with PLCs via an integrated point-to-point or multidrop serial link, or via a field bus with a PCMCIA Type III card. The communication protocols are those used by Schneider Electric PLCs as well as those of the other main market suppliers. PLC 4 999 000 Schneider Electric All Rights Reserved /00
XBTF Terminals with Graphic Screen Functions XBTF graphic screen operator dialogue terminals have the following functions: Displaying animated synoptic screens, control, modification of numeric and alphanumeric variables Displaying a service line (status and alarm bar) with the current time Dynamic visualization of operating data (setpoints, measurements, recipes, maintenance messages) and process errors Control via dynamic or static function keys Scaling analog variables Real-time and trending curves Alarm log and managing alarm groups Managing help pages, form pages, recipe pages Pages called by the user or by the PLC Three levels of passwords Printing form pages, date-stamped log and alarms Communication protocol application support in the PCMCIA Type II application memory card The role of the function keys is defined using the XBTL00 software. Modifications cannot be made during operation. Each function key can be associated with an internal bit of the PLC application. Static Function Keys (F ) Static function keys are defined for the whole application. They perform the following actions: Accessing a page Pulse control Toggle set/reset control Static keys can be marked with reusable labels. Dynamic function keys and touch-sensitive keys Dynamic function keys and touch-sensitive keys are associated with a page. Their role can therefore differ from one page to another. They perform the following actions: Accessing a page Latching memory bits Toggling memory bits (on/off) Accessing the modification of a value Direct writing Each dynamic key and touch-sensitive key can be assigned a label or icon illustrating its function. On touch-sensitive terminals, the touch-sensitive zones function in a similar way to the dynamic keys on keypad terminals. /00 999 000 Schneider Electric All Rights Reserved
XBTF Terminals with Graphic Screen Service Keys Service keys are the arrow keys and the control keys combined. Service keys are used to modify the parameters of the control system. The control keys perform the following actions: ENTER MOD ESC SHIFT MENU HOME SYST ALARM PRINT Confirm a selection or entry, acknowledge an alarm Change to the mode for entering pages, passwords, fields, or graphic objects Cancel an entry, suspend or stop a current action; display previous pages in succession; quit the alarm display Access the second of the dual key functions Access a menu containing the operating functions that do not have direct access keys Return to the entry point of the current menu Example: return to the first page of the application Access the confidential mode that contains the passwordprotected implementation functions View the alarms Print The arrow keys perform the following actions: Change the page within a menu Change fields on a page Select an object on a page Move within a page Select the value of a digit Select a value from a list of choices When used with the SHIFT key, increment or decrement the value of a variable field 999 000 Schneider Electric All Rights Reserved /00
XBTF Terminals with Graphic Screen XBTF0/F0 Description The front panel of XBTF0/F0 keypad terminals includes: 3 4. A monochrome or color screen.7, 9., or 0.4 in. (4, 4, or 4 mm) depending on the model. x 4 or x dynamic function keys (depending on the model) with indicator lights 3. A communication monitoring indicator light 4. A keypad activity indicator light. x or x static function keys (depending on the model) with indicator lights and re-usable labels. Twelve service keys with indicator lights 7. Twelve alphanumeric keys [0 to 9, (+/ ), (.)] associated with three alphabetical access keys (A to Z) 7 The front panel of XBTF03 touch-sensitive screen terminals includes: 3. A touch-sensitive color screen.7 or 0.4 in. (4 or 4 mm) depending on the model. A communication monitoring indicator light 3. A tactile feedback activity indicator light The front panel of XBTFC touch-sensitive screen terminals includes: 3 4. A touch-sensitive color screen.7 or 0.4 in. (4 or 4 mm) depending on the model. A communication monitoring indicator light 3. A tactile feedback activity indicator light 4. An alarm indicator light. 4, 8,, or touch-sensitive keys (depending on the Touch n Click model) /00 999 000 Schneider Electric All Rights Reserved 7
XBTF Terminals with Graphic Screen Selection Terminals with Keypads Downloadable Exchange Protocol Type and Size of Screen Supply Voltage (VDC) Type III Slot for PCMCIA Communication Card Number Monochrome.7 in. (4 mm) 4 No XBTF00 4.0 (.8) Yes XBTF030 4.0 (.8) See page 7 Monochrome 9. in. (4 mm) 4 No XBTF030.0 (.7) Yes XBTF0330.0 (.7) XBTF04 0 Color 0.4 in. (4 mm) 4 No XBTF040.0 (.7) Yes XBTF0430.0 (.7) XBTF034 0 Terminals with Touch-Sensitive Screens Downloadable Exchange Protocol See page 7 Type and Size of Screen Color.7 in. (4 mm) Color 0.4 in. (4 mm) Supply Voltage (VDC) 4 4 Type III Slot for PCMCIA Communication Card Number No XBTF030 3. (.) Yes XBTF0330 3. (.) No XBTF0340.3 (.4) Yes XBTF03430.3 (.4) Separate Parts Description Use Number Development Software Under Windows 9 or NT 4.0, for downloading the application and protocols See page 7 PCMCIA Type II Memory Cards Application memory See page 7 PCMCIA Type III Memory Cards Bus and industrial networks connection See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Sheet of Labels Labels for function keys See page 7 XBTMEM08 Replacement Parts Description Use Memory PCMCIA Type II Memory Card PCMCIA Type II Memory Card Number XBTF terminals 8 MB XBTMEM08 0. (0.) XBTF terminals MB XBTMEM 0. (0.) 8 999 000 Schneider Electric All Rights Reserved /00
XBTF Terminals with Graphic Screen Specifications Type of Terminal XBTF0 XBTF03 XBTF03/F04 XBTF034 Environment Conforming to Standards IEC 3-, IEC 080- level 3, IEC 080-3 and IEC 080-4 level 3, IEC 008--, IEC 008--7, UL 08, CSA C. No. 4 Product Certifications CE, UL, CSA, UL E48, CCN: NRAQ, CSA LR 44087, Class 0 Temperature Operation +3 to +3 F (0 to +4 C) Storage 4 to +40 F ( 0 to +0 C) Degree of Front Panel IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Protection Rear Panel IP 0, conforming to IEC 09 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with spring clips (supplied), pressure-mounted on a panel of thickness 0.0 0.4 in. (. mm) 0 spring clips 8 spring clips spring clips 0 spring clips Material Front Section Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keys Dynamic Keys 8 (with LED) 0 (with LED) Static Keys 0 (with LED and re-usable labels) (with LED and re-usable labels) Service Keys Alphanumeric Keys Electrical Characteristics, plus 3 for alphabetical access LED Screen Type.7 in. (4 mm) monochrome, back-lit with levels of grey.7 in. (4 mm) STN colors, back-lit with resistive matrix tactile feedback, plus 3 for alphabetical access XBTF03: 9. in. (4 mm) monochrome, back-lit with levels of grey XBTF04: 0.4 in. (4 mm) TFT colors Resolution 30 x 40 pixels 40 x 480 pixels 0.4 in. (4 mm) TFT colors with resistive matrix tactile feedback Power Supply Voltage 4 Vdc not isolated Voltage Limits 8 30 V, maximum ripple %, maximum microbreaks ms Protection Against polarity inversion and overloads Consumption 3 W Operating Characteristics Signaling LED for communication monitoring, LED for keypad activity (or tactile feedback activity), and LEDs associated with service and alphanumeric keys Operating System Dynamic RAM Memory Application Memory Dialogue Application Max. number of pages MAGELiS. MB On 8 MB PCMCIA Type II card (supplied), 8, MB 0 40 application, alarm, help, form, and recipe pages depending on the memory card used Curves real-time curves real-time curves Real-Time Clock Access to the PLC real-time clock Alarm Relay One volt-free N.O. contact, max. 0. A, 4 Vdc/Vac Connection Power Supply Plug-in terminal, screw terminals, 3/4 (.08 mm) pitch and Maximum clamping capacity: # AWG (. mm Alarm Relay ) PLC Female -pin SUB-D connector Printer/ Configuration Male 9-pin SUB-D connector PC 30 300 application, alarm, help, form, and recipe pages depending on the memory card used /00 999 000 Schneider Electric All Rights Reserved 9
XBTF Terminals with Graphic Screen Touch n Click Terminals Terminals with touch-sensitive screens XBTFC030 Downloadable Exchange Protocol Type and Size of Screen Supply voltage (VDC) Number of touchsensitive keys Number lb (kg) Color.7 in. (4 mm) 4 4 XBTFC030 3. (.) See page 7 Color 0.4 in. (4 mm) 4 8 XBTFC04430.3 (.4) XBTFC08430.3 (.4) XBTFC0430.3 (.4) XBTFC04430 Separate parts XBTFC08430 Description Use Number Development Software Under Windows 9 or NT 4.x, for downloading the application and protocols See page 7 Type II PCMCIA Memory Cards Application memory See page 7 Type III PCMCIA Communication Cards Connection to buses and industrial networks See page 7 Connecting Cables Serial link, UNI-TELWAY bus, configuration terminal, printer connection lb (kg) See page 7 Replacement part XBTFC0430 Description Use Memory size Number lb (kg) Type II PCMCIA Memory Card XBTFC terminals 8 MB XBTMEM08 0. (0.) Type II PCMCIA Memory Card XBTFC terminals MB XBTMEM 0. (0.) XBTMEM08 70 999 000 Schneider Electric All Rights Reserved /00
XBTFC Touch n Click Terminals MAGELiS terminals with graphic screen Characteristics Type of terminal XBTFC030 XBTFC04430 XBTFC08430 XBTFC0430 Environment IEC 3-, IEC 000-4- level 3, IEC 000-4-3 and IEC 000-4-4 level 3, IEC 008--, Conforming to Standards IEC 008--7, UL 08, CSA C. No. 4 Approvals CE, UL, CSA Temperature Relative humidity Operation Storage +3 to +3 F (0 to +4 C) 4 to +40 F ( 0 to +0 C) 0 8% (without condensation) Degree of Front panel IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Protection Back panel IP 0, conforming to IEC 09 Shock Resistance Conforming to IEC 008--7; semi-sinusoidal pulse ms, g in the 3 axes Vibrations Conforming to IEC 008--; 0 7 Hz at 0.07 mm (0.003 in.); 7 0 Hz g for 3 hours per axis Electrostatic Discharge Conforming to IEC 000-4-, level 3 Electromagnetic Interference Conforming to IEC 000-4-3, 0 V/m Electrical Interference Conforming to IEC 000-4-4, level 3 Mechanical Characteristics Flush-mounted, fixed with spring clips (supplied), Mounting and Fixing pressure-mounted on a panel of thickness 0.0 0.4 in. (. mm) 8 spring clips 0 spring clips Screen protection. mm (0.0 in.) polyester mm (0.08 in.) polyester Material Front frame Polyphenyl oxide, 0% glass fibre (PPO GFN SE ) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) Enclosure Polyphenyl oxide, 0% glass fibre (PPO GFN SE ) Touch-Sensitive Keys 4 in one row 8 in one row in two rows in two columns Electrical Characteristics.7 in. (4 mm) STN colors back-lit with resistive matrix tactile feedback (8 x 4 cells) 0.4 in. (4 mm) TFT colors with resistive matrix tactile feedback XBTFC04 has 3 x 8 cells, XBTFC0 has 9 x 0 cells, XBTFC 08 has 3 x cells Type LCD Screen Definition 30 x 40 pixels 40 x 480 pixels Voltage 4 Vdc not isolated Power Supply Limits 8 30 V, including % maximum ripple, microbreaks ms maximum Protection Against polarity inversion and overloads Consumption 3 W Operating characteristics Signaling communication monitoring LED, keypad activity LED and alarm LEDs Operating System MAGELiS Dynamic RAM Memory. MB Application Memory On Type II PCMCIA card: 8 MB (supplied) or MB Dialogue Application Maximum no. of pages 0 40 application, alarm, help, form, and recipe pages depending on the memory card used ( alarm and form max.) 30 300 application, alarm, help, form, and recipe pages depending on the memory card used ( alarm and form max.) Curves real-time curves Recipes Maximum 000 parameter values in a maximum of recipe records PLC/ Configuration PC RS 3 C / RS 4 / RS 48 isolated serial link, downloadable communication protocols (see pages and 3) Communication Printer RS 3 C serial link Bus or network Slot for Type III PCMCIA communication card, communication protocols (see page 3) Real-Time Clock Access to the PLC real-time clock Alarm Relay volt-free N.O. contact, max 0. A, 4 Vdc/Vac Connection Power supply and alarm relay PLC Printer/ Configuration PC Plug-in terminal block, screw terminals at intervals of 3/4 (.08 mm) Max clamping capacity: # AWG (. mm ) -pin female SUB-D connector 9-pin male SUB-D connector /00 999 000 Schneider Electric All Rights Reserved 7
Development Software XBTL003/L004 Software Functions Simulation on PC compatible XBTL003/L004 software offers the option of simulating all the operator dialogue applications from the design office without the use of graphic terminals and PLCs. The following can be tested using the simulation program and the keyboard on a PC compatible: Navigating between pages Entering variables Displaying variables Simulating an alarm Using the function keys The operator terminals and graphic stations have two types of function keys: static and dynamic.. Static keys These are defined for the whole application. They may have the following functions: Access a page Pulse a PLC memory bit Latch a PLC memory bit. Dynamic keys These are associated with one page. Their role can be reassigned or changed from one page to another. They may have the following functions: Access a page Pulse a PLC memory bit Latch a PLC memory bit Position on a data entry field A label (bitmap image) is assigned to each key, which may vary from page to page. 7 999 000 Schneider Electric All Rights Reserved /00
Development Software XBTL003/004 Software XBTL003/L004 development software is used with the whole range of MAGELiS terminals to create operator dialogue applications designed for controlling automated systems. XBTL003/L004 software runs on PC compatibles equipped with Windows 9 or NT 4.0 operating software. Applications created using XBTL003/L004 software are independent of the protocol used; it is possible to use the same operator dialogue application with all the different PLCs offered by the main market suppliers. Configuration XBTL003/L004 software is the only configuration software package for the MAGELiS range. It runs under Windows 9 or NT 4.0. It is used to create various types of pages easily: Application pages (can be interlinked) Alarm pages Help pages Recipe pages Form pages The pages can contain all sorts of variables and graphic objects, which are either predefined in the XBTL003/L004 software or created using other applications and then imported (bitmap format, etc.). Various properties can be assigned to them: min-max limits, color, movement, weighting, etc. XBTL003/L004 software can be used to configure the function keys to activate commands on the machine or call application pages. It can also be used on the graphic terminals to import the PL7 or CONCEPT PLC symbols database. Main toolbar Midday Bakery Bread Recipe Flour Soda Water Select the quantities of each product Page Information window Use the? button for more information Graphic toolbar Page Tree Structure window The XBTL000 software package is designed for DOS.0 (minimum) with the Windows 3. operating system. Hardware requirements are a minimum of a 38 processor operating at MHz, with 8 MB RAM and 0 MB free hard disk space. /00 999 000 Schneider Electric All Rights Reserved 73
Development Software Screen windows XBTL003/L004 software is used to design page contents in WYSIWYG (what you see is what you get): anything created using the software is displayed in exactly the same way on the operator dialogue terminal screen. To assist the designer, the software offers a display unit or a virtual screen depending on the type of terminal. XBTHP XBTE XBTHM XBTF Model pages Midday Bakery Model pages, created by the designer, are pages whose graphic format (text, images, or static objects) applies to all other pages in the same family. There are three types of model pages: Application Alarm Help Model pages are available with XBTF graphic terminals. Alarm pages Alarm pages indicate any faults in the process. The advantage of alarm pages lies in their event-triggered display: During operation When a fault occurs, it is often the consequence of other faults. The priority levels enable the terminal to display the most important fault: the one presenting the highest risk to the process. The occurrence of any fault is time and date stamped. During maintenance operations The terminal memorizes the faults in sequence (log) making it easy to find the cause of the fault. Help pages and help windows Help pages and windows can be associated with application or alarm pages. Help windows can be associated with any variable field. 74 999 000 Schneider Electric All Rights Reserved /00
Development Software Software for MAGELiS Terminals Multilingual software packages are designed for FTX 7 terminals or PC compatibles (minimum requirements: 48 processor, MHz, 30 MB free space on the hard disk and either 8 MB RAM memory with a Windows 9 operating system or MB RAM memory with an NT 4.0 operating system). They include the following communication protocols: UNI-TELWAY, FIPIO, FIPWAY, MODBUS, Jbus, MODBUS Plus, KS. Schneider Pack Software (with Schneider Electric Protocols) Description Compatibility Operating System Support Documentation for alphanumeric and graphic terminals Number XBTL003 French XBTL003F 3.3 (.) Alphanumeric and graphic configuration XBTH/P/E/HM/PM XBTF Windows 9, 98, 000, or NT 4.0 CD-ROM English XBTL003E 3.3 (.) German XBTL003G 3.3 (.) Spanish XBTL003S 3.3 (.) Italian XBTL003T 3.3 (.) Note: Packages contain the XBTZ9 cable and -pin/9-pin connection interface XBTZ9. Open Pack Software (with Schneider Electric and Third Party Protocols) XBTL004 Description Alphanumeric and graphic configuration Compatibility XBTH/P/E/HM/PM XBTF Operating System Windows 9, 98, 000, or NT 4.0 Support CD-ROM Note: Packages contain the XBTZ9 cable and -pin/9-pin connection interface XBTZ9. Documentation Number French XBTL004F 4.4 (.0) English XBTL004E 4.4 (.0) German XBTL004G 4.4 (.0) Spanish XBTL004S 4.4 (.0) Italian XBTL004T 4.4 (.0) Schneider Update Pack with Schneider Electric Protocols Description Compatibility Operating System Support Documentation Number Alphanumeric and graphic configuration XBTH/P/E/HM/PM XBTF/XBTFC Windows 9, 98, 000, or NT 4.0 CD-ROM Five-language PDF format XBTLUP003. (0.) Schneider Pack Software with Schneider Electric Protocols (Light Pack) Description Compatibility Operating System Support Documentation Number Alphanumeric configuration XBTH/P/E Windows 3. or Windows 9 Diskette Ordered separately XBTL000. (0.) Diagnostic Viewer/Remote Network Transfer Option Description Alphanumeric and graphic configuration Compatibility XBTH/P/E/HM/PM XBTF/XBTFC Operating System Windows 9, 98, 000, or NT 4.0 Diagnostics with PL7PRO on TSX7 Premium. Remote transfer over MODBUS Plus or FIPWAY. Dynamic database link from PL7PRO or CONCEPT to XBTL000 Support Documentation Number CD-ROM None TXBTLDIAGCDM. (0.) For a list of Schneider Electric and third party protocols, refer to page 7. /00 999 000 Schneider Electric All Rights Reserved 7
Separate Parts Downloadable protocols (onto diskettes) PLC Brands Compatibility Name of Protocol Number Schneider Electric Allen Bradley XBTH/P/E (only for XBTL000 software) XBTH/P/E/HM XBTF lb (kg) UNI-TELWAY V.0 UNI-TELWAY V.0 XBTLUTW0.43 (0.) MODBUS Jbus XBTLMOD0.43 (0.) KS XBTLAEG0.43 (0.) DF DH48 XBTLAB0.43 (0.) GE Fanuc XBTH/P/E SNPX XBTLGE0.43 (0.) Omron Siemens XBTH/P/E/HM XBTF Sysmacway XBTLOMR0.43 (0.) XBTH/P/E/HM AS 394R XBTLSIE0.43 (0.) XBTF PPI, MPI XBTLSIE0.43 (0.) Communication on buses and networks Type of Protocol Compatibility Support Number lb (kg) AS-i XBTH/P/HM Module at. intervals XBTZA994 0. (0.30) MODBUS Plus XBTF Type III PCMCIA TSXMBP00.43 (0.) FIPIO XBTF Type III PCMCIA TSXFPP0.43 (0.) FIPWAY FIPWAY on XBTF Type III PCMCIA TSXFPP0.43 (0.) Type II PCMCIA memory cards XBTMEM08 Size Compatibility Approximate Number of Pages Number XBTF0/F03/FC0 XBTF0/F034/FC04 lb (kg) 8 MB XBTF 30 30 XBTMEM08 0. (0.0) MB XBTF 70 480 XBTMEM 0. (0.0) Note: The XBTF terminal comes with an 8 MB PCMCIA card. Accessories Type Sold in Lots of Compatibility Number Sheets of re-usable labels XBTH0 00 XBTP0 00 XBTP0 0 XBTE XBTHM XBTF0 XBTF0 XBLYH4 XBLYP8 XBLYP XBLYE4 XBLYHM4 XBLYF0 XBLYF lb (kg) 0. (0.0) Desk holder XBTF XBTZ300 0.44 (0.0) XBTHM/F XBTZ300 0.44 (0.0) Spring clips 0 XBTH/P/E XBTZ3003 0.44 (0.0) Power supply connector 0 XBT XBTZ3004 0.44 (0.0) Connection to PCs and printers Use Connection Compatibility Number lb (kg) RS3C PC link (. m) 9-pin (male) Any XBT XBTZ9 0.44 (0.0) Between XBTZ9 cable and XBTF terminal 9-pin/-pin XBTF XBTZ9 0. (0.0) Serial printer with printer port 9-pin/-pin Any XBT XBTZ93 0.44 (0.0) 7 999 000 Schneider Electric All Rights Reserved /00
Separate Parts Cables for connecting MAGELiS terminals to PLCs Direct connection of XBTH/P/E/HM/PM/F/FC terminals to Schneider Electric PLCs XBTZ98 Type of PLC to be Connected Nano, Micro, Premium Premium with TSXSCY0 Type of Connector Physical Link Protocol 8-pin female mini-din terminal port RS 48 -pin female SUB-D RS 48 UNI-TELWAY (V.0/V.0) UNI-TELWAY (V.0/V.0) Length ft (m) Number lb (kg) 8. (.) XBTZ98 0.40 (0.8).4 (.0) XBTZ98 0.7 (0.34).48 (.0) XBTZ98.40 (0.3) 8. (.) XBTZ98 0. (0.3) Quantum 9-pin male SUB-D RS 3 MODBUS 8. (.) XBTZ970 0.4 (0.) TSX7 TSX7 with TSXSCG TSX Series 7 model 40 on processor TSX Series 7 model 40 with TSXSCM -pin female SUB-D terminal port RS 48 -pin female SUB-D RS 48 TSXLES4/74 cable connector RS 48 -pin female SUB-D RS 48 UNI-TELWAY (V.0) UNI-TELWAY (V.0) UNI-TELWAY (V.0) UNI-TELWAY (V.0).4 (.0) XBTZ98 0.3 (0.4).4 (.0) XBTZ98 0.3 (0.4).4 (.0) XBTZ948 0. (0.3).4 (.0) XBTZ98 0. (0.3) MODICON 984 9-pin male SUB-D RS 3 MODBUS 8. (.) XBTZ970 0.4 (0.) MODICON Micro RJ 4 male jack RS 3 MODBUS 8. (.) XBTZ97 0.4 (0.) AEG ALU 9-pin male SUB-D RS 3 KS 8. (.) XBTZ97 0.4 (0.) AEG Micro RJ 4 male jack RS 3 KS 8. (.) XBTZ97 0.4 (0.) LT -pin female SUB-D RS 3 MODBUS 8. (.) XBT970 0.4 (0.) Direct connection of XBTH/P/E/HM/PM/F/FC terminals to third-party PLCs Type of PLC Being Connected Type of Connector Physical Link Protocol Length ft (m) Number lb (kg) Allen Bradley SLC 9-pin male SUB-D RS 3 DF 8. (.) XBTZ9730 0.4 (0.) Allen Bradley PLC -pin female SUB-D RS 3 DF 8. (.) XBTZ970 0.4 (0.) Allen Bradley Micro-logix Micro-logix 000 RS 3 DF DH48 8. (.) XBTZ973 XBTZ973 0.4 (0.) GE Fanuc Series 90 -pin male SUB-D RS 3/4 SNPX 8. (.) XBTZ970 0.4 (0.) Omron CQM, CVM 9-pin male SUB-D RS 3 Sysmacway 8. (.) XBTZ9740 0.4 (0.) Omron CVM 9-pin male SUB-D RS 4 Sysmacway 8. (.) XBTZ974 0.4 (0.) Siemens S7 PG 9-pin male SUB-D RS 3 PPI 8. (.) XBTZ97 0.4 (0.) Siemens S CP -pin female SUB-D RS 3 394(R) 8. (.) XBTZ970 0.4 (0.) Siemens S PG -pin female SUB-D CL/RS 3 converter AS 8. (.) () Order both XBTZ939 and XBTZ909 cables. () CL/RS3 converter XBTZ939 is only for use with Siemens PLCs. XBTZ939 + XBTZ909 ()() 0.48 (0.) Bus and network connection Type of Bus/Network Tap-off Unit Type of Connector Length ft (m) Number lb (kg) AS-i XBTZA994 8. (.) XBTZ970 0.44 (0.0) TSXSCA -pin female SUB-D.9 (.8) XBTZ908 0.3 (0.4) subscriber socket UNI-TELWAY TSXPACC0 8. (.) XBTZ98 0.40 (0.8) 8-pin female mini-din cable connector.4 (.0) XBTZ98 0.7 (0.34) FIPIO/FIPWAY/MODBUS Plus See page 78 /00 999 000 Schneider Electric All Rights Reserved 77
XBTF Bus and Network Connections Connections to FIPIO bus, FIPWAY and MODBUS Plus networks Connection to FIPIO bus XBT-F 3 FIPIO FIPIO 3 4. TSXFPCA 00: shielded twisted pair trunk cable, 0 Ω, 0.3 in. (8 mm) dia. for normal environment or indoors or TSXFPCR 00: shielded twisted pair trunk cable, 0 Ω, 0.3 in. (8 mm) dia. for harsh environment or outdoors. TSXFPACC4: IP T-junction box 3. TSXFPP0: PCMCIA card, FIPIO agent function 4. TSXFPP0: PCMCIA card, FIPIO/FIPWAY. TSXFPCG0 0: tap-off connecting cable for PCMCIA TSXFPP0/0 module card. TSXFPACC7: line terminator to be placed at each segment end Micro Premium Connection to FIPWAY network XBT-F 3 4 FIPWAY FIPWAY 4 3 3 4. TSXFPCA 00: shielded twisted pair trunk cable, 0 Ω, 0.3 in. (8 mm) dia. for normal environment or indoors or TSXFPCR 00: shielded twisted pair trunk cable, 0 Ω, 0.3 in. (8 mm) dia. for harsh environment or outdoors. TSXFPACC4: IP T-junction box 3. TSXFPP0: PCMCIA card, FIPIO/FIPWAY 4. TSXFPCG0 0: tap-off connecting cable for PCMCIA TSXFPP0/0 module card. TSXFPACC7: line terminator to be placed at each segment end Micro Premium Connection to MODBUS Plus network MODBUS Plus XBTF 4. 490NAA70 : trunk cable. 990NAD3000: IP 0 T-junction box 3. ASMBKT8: line terminator for placement at each segment end 4. TSXMBP00: PCMCIA card, MODBUS Plus for XBTF. TSXMBPCE0 0: tap-off cable. 990NAD 0: tap-off cable MODBUS Plus 3 4 4 3 Micro Premium Quantum 78 999 000 Schneider Electric All Rights Reserved /00
XBTF Bus and Network Connections FIPWAY network/fipio bus connection cables and accessories () TSX FPP 0 TSX FP ACC 4 TSX FP ACC 7 Description Type Condition of use Length ft (m) Number lb (kg) FIPIO PCMCIA card Agent function FIPIO on XBTF TSXFPP0 0.4 (0.) FIPWAY PCMCIA card FIPWAY on XBTF TSXFPP0 0.4 (0.) Trunk cables Dust and damp-proof junction box Line terminators (sold in lots of ) Tap-off connection cables Description Cables for PCMCIA card 8 mm, shielded twisted pair 0 Ω 8 mm, shielded twisted pair 0 Ω In normal environment () and indoors In harsh environment (3) outdoors or in a daisychain (4) 38 (00) TSXFPCA00. (.8) (00) TSXFPCA00 4.07 (0.9) 40 (00) TSXFPCA00.4 (30.00) 38 (00) TSXFPCR00.93 (7.8) (00) TSXFPCR00 3.89 (4.9) 40 (00) TSXFPCR00 88.8 (40.00) Zamac, IP Trunk cable tap link TSXFPACC4.4 (0.) TSXFPACC7 0.04 (0.0) From TSXFPP0/0 card Use To TSXFPACC4 junction box Length ft (m) Number lb (kg) 3 () TSXFPCG00 0.4 (0.) 0 (3) TSXFPCG030 0.90 (0.4) TSX FP CG 0 0 () The specifications and performance of the FIPIO bus or FIPWAY network depend on the use of these TSXFP accessories. () Normal environment: no special environmental constraints operating temperature between + C and +0 C fixed installations (3) Harsh environment: resistance to hydrocarbons, industrial oils, detergents and solder chips relative humidity up to 00% saline environment extreme variations in temperatures operating temperature between 0 C and +70 C mobile installations (4) Use in a daisy-chain: radius of curvature = 0 x cable diameter, either 3. or 3.7 in. (80 or 9 mm). For other special restrictions, please consult your regional sales office. MODBUS Plus network connection cables and accessories TSX MBP 00 TSX MBP CE 0 0 Description Use Number lb (kg) MODBUS Plus PCMCIA card XBTF TSXMBP00 0.4 (0.) MODBUS Plus junction box IP 0 T-junction box 990NAD3000 0. (0.3) Line terminators (sold in lots of ) ASMBKT8 Connection cables Description From Use MODBUS Plus trunk cables Junction box Junction box Tap-off cables TSXMBP00 PCMCIA card Quantum PLC To 990NAD3000 junction box 990NAD3000 junction box Length ft (m) Number lb (kg) 98 (30) 490NAA70 49 (0) 490NAA70 984 (300) 490NAA703 47 (40) 490NAA704 49 (00) 490NAA70 0 (3) TSXMBPCE030 0.7 (0.34) 0 () TSXMBPCE00.7 (0.3) 7.9 (.4) 990NAD0.7 (0.3) 0 () 990NAD30.7 (0.3) /00 999 000 Schneider Electric All Rights Reserved 79
+4 V 4 V MAGELiS Operator Terminals Wiring Diagrams The following information provides specific details for one electrical connection and two serial communication ports of the XBT terminals. Figure shows the location of the electrical connection and the serial communications ports. XBTH XBTP A B C A B C............ Legend: A = Electrical Connection B = Serial Communication C = Serial Printer Line (RS-3C) A B C...... XBTE C B A XBTF0...... XBTF03... B C A! 4 Vdc Figure 4: Electrical Connections and Serial Communications Electrical Connections The power supply connections and the XBTE relay connections should be made following the connection schemes shown in Figure. XBTH/P +4V XBTF0 XBTF0 XBTF03 3 4XBTE XBTE Relay Output Usage Limits.0 ma, Vac/Vdc min. 0. A, 4 Vac/Vdc max. XBTE XBTH/P XBTHM/PM XBTF FLUO LCD Maximum Consumption 0 W W 3 W 0 W 0 W Nominal Voltage 4 Vdc Voltage Limits (including ripple) 8 30 V Figure : Electrical Connections 80 999 000 Schneider Electric All Rights Reserved /00
Wiring Diagrams Serial communication Figures and 7 show the pin arrangements of the serial communication link and the serial printer link. 3 4 7 8 9 0 3 4 7 8 9 0 3 4 3 4 7 8 9 0 3 4 7 8 9 0 3 4 PG TXD RXD A B A' 0 V iso COM REG CONF B0 B B B3 B' B4 0 V iso PAR Protective Ground RS-3C / V4 TXD: transmission 3 RXD: reception 7 0 V iso: common RS-4 / 48 4 A transmission B A' reception 8 B' 7 0 V iso: common Multipoint 8 COM (0 V): common 4 B0 B B address code 7 B3 9 B4 4 PAR: parity Figure : Serial Communication Link Reserved 3 4 7 8 9 3 4 RXD TXD DTR COM (0 V) DSR Reserved RS-3C transmission Power up XBT Common RS-3C Printer ready 7 RTS Request to send 8 CTS Printer ready 9 Figure 7: Serial Printer Link /00 999 000 Schneider Electric All Rights Reserved 8
Wiring Diagrams Cable Pinouts The following pages show cable pinout diagrams for XBT MAGELiS terminal cables. MAGELiS to PC (XBTZ9) Cable XBT-Z9 Cable, Version. 8. ft (. meters) MAGELiS XBT SUB-D -pin male PC SUB-D 9-pin female 4 3 Shielding TD RD 3 SG 7 COM 8 CONF 3 PG RD 3 TD SG 7 RTS 8 CTS DSR 4 DTR 9 MAGELiS XBTZ9 Adapter/Application Transfer XBTF XBTZ9 SUB-D -pin female 4 3 XBTZ9 Adapter RXD TXD 3 GND 7 7 RTS 8 CTS RXD 3 TXD GND DCD 4 DTR DSR 9 RI XBTF SUB-D 9-pin female 9 XBTF TSX Nano/TSX Micro/TSX Premium to MAGELiS (XBTZ98 ) Cable TSX07/37/7 Mini DIN 8-pin male programming port XBT-Z98 Cable, 8. ft (. meters) V. XBT-Z98 Cable,.4 ft ( meters) V. XBT SUB-D -pin male 8 Shielding D( ) D(+) OVL 7 +V 8 TP 4 A A'' B 8 B'' OVL 4 B0 B 7 B3 9 B4 4 P 8 COM 4 3 7 GRD SDOWN 0 +V 8 999 000 Schneider Electric All Rights Reserved /00
MODICON Micro/TSX Compact/MOMENTUM to MAGELiS Cable Modicon Micro/TSX Compact (MODBUS Port) to XBT cable (XBTZ97) MAGELiS Operator Terminals Wiring Diagrams MAGELiS XBT SUB-D -pin male Modular Jack RJ4 4 3 TD RD 3 SG 7 8 4 RD 3 TD SG RTS 7 CTS NC DSR Red Black Green Yellow Brown Blue Orange 8 Compact 984 (984-0/30-3/4-4/4-4) MODBUS Port to MAGELiS Cable Compact 984 to XBT Cable (XBTZ970) MAGELiS XBT SUB-D -pin male Compact 984 SUB-D 9-pin male 4 3 TD RD 3 SG 7 8 RD 3 TD SG 7 RTS 8 CTS 4 DTR DSR 9 /00 999 000 Schneider Electric All Rights Reserved 83
Wiring Diagrams Quantum (MODBUS Port) to MAGELiS Cable MAGELiS XBT SUB-D -pin male Quantum to XBT Cable (XBTZ970) Quantum SUB-D 9-pin 4 3 TD RD 3 SG 7 8 RD 3 TD SG 7 RTS 8 CTS 4 DTR DSR 9 MAGELiS to MODICON Cable (RS-3 C, with MODBUS Protocol) XBT MAGELiS Terminal PLC Coupler MODBUS PG PG Transmission TXD TXD Transmission Reception RXD 3 3 RXD Reception 0 V SG 7 7 SG 8 4 RTS CTS DSR 0 DTR Connection of shielding to both cable ends depends on the electrical operating conditions. In some configurations, it is not necessary to reverse pins and 3. Consult the appropriate PLC documentation. 84 999 000 Schneider Electric All Rights Reserved /00
MAGELiS to MODICON Cable (RS-4/48, with MODBUS Protocol) RS 4 LINK MAGELiS Operator Terminals Wiring Diagrams XBT MAGELiS Terminal PLC 0 V SG SG9 0 V Transmission E TXD+ TXD A B 4 Rt A' B' RXD+ R RXD Reception + V RXD+ R Rp Rp RXD 0 V Reception A' B' PG 8 Rt A B PG TXD+ TXD E Transmission 8 RS 48 LINK XBT MAGELiS Terminal PLC PG PG 0 V SG SG 0 V E TXD+ TXD A B 4 Rt Rt A' B' RXD+ R RXD + V RXD+ R Rp Rp RXD 0 V A' B' 8 8 A B TXD+ TXD E Connection of shielding to both cable ends depends on the electrical operating conditions. Rt: Link termination resistor (normally 0 Ω). NOTE: The Rp resistors (4.7 kω) are integrated in the XBT. /00 999 000 Schneider Electric All Rights Reserved 8
Wiring Diagrams MAGELiS (XBTZ970) to Siemens Cable (RS-3 C, with 394/394R Protocol) XBT MAGELiS Terminal PLC Siemens PG PG Transmission TXD TXD Transmission Reception RXD 3 3 RXD Reception 0 V SG 7 7 SG 8 4 RTS CTS DSR 0 DTR Connection of shielding to both cable ends depends on the electrical constraints of the installation. In some configurations, it is not necessary to reverse pins and 3. Consult the appropriate PLC documentation. MAGELiS (XBTZ939 and XBTZ909) to Siemens Cable (RS-3 C, with AS Protocol) Current Loop RS-3 Converter PG PG 4 +. V XBT TXD RXD SG 3 7 RxD+ RxD- TxD+ 9 0 0 9 TTY IN+ TTY IN- TTY OUT+ Programming port 8 TxD- 7 TTY OUT- 8 M reference potential XBT-Z939 XBT-Z909 Connector SUB-D male / SUB-D female 8 999 000 Schneider Electric All Rights Reserved /00
MAGELiS to Siemens Cable (RS-4, with 394/394R Protocol) MAGELiS Operator Terminals Wiring Diagrams XBT MAGELiS Terminal PLC Siemens 0 V SG SG9 0 V Transmission E TXD+ TXD A B 4 Rt A' B' RXD+ R RXD Reception + V RXD+ R Rp Rp RXD Reception 0 V A' B' PG 8 Rt A B PG TXD+ TXD E Transmission 8 Connection of shielding to both cable ends depends on the electrical operating conditions. Rt: Link termination resistor (normally 0 Ω). NOTE: The Rp resistors (4.7 kω) are integrated in the XBT. MAGELiS (XBTZ97) to Siemens Cable (PP RS-48) Siemens SUB-D 9-pin male MAGELIS XBT SUB-D -pin male 8 3 PG SG 4 A TxD+ B TxD 8 A' RxD+ B' RxD 8 4 3 /00 999 000 Schneider Electric All Rights Reserved 87
Wiring Diagrams MAGELiS (XBTZ970) to Allen Bradley Cable (RS-3 C) XBT MAGELiS Terminal DFI AB PG PG Transmission TXD TXD Transmission Reception RXD 3 3 RXD Reception 0 V SG 7 7 SG 8 4 RTS CTS DSR 0 DTR Connection of shielding to both cable ends depends on the electrical constraints of the installation. In some configurations, it is not necessary to reverse pins and 3. Consult the appropriate PLC documentation. MAGELiS (XBTZ973) to Allen Bradley Cable (Micro-logix) AB DF Mini DIN 8-pin MAGELIS XBT SUB-D -pin male 8 Shielding TP 3 TxD 7 3 RxD RxD 4 TxD 4 SG 7 SG 8 88 999 000 Schneider Electric All Rights Reserved /00
Wiring Diagrams MAGELiS (XBTZ9730) to Allen Bradley Cable (SLC) AB DF SUB-D 9-pin MAGELIS XBT SUB-D -pin male PG TD 7 Shielding TD 3 RD SG 3 3 RD 7 SG 4 8 COM CTS /00 999 000 Schneider Electric All Rights Reserved 89
Wiring Diagrams MAGELiS (XBTZ9740) to Omron Cable (RS-3 C) XBT MAGELiS Terminal PLC Omron PG PG Transmission TXD TXD Transmission Reception RXD 3 3 RXD Reception 0 V SG 7 9 SG 8 4 RTS CTS Connection of shielding to both cable ends depends on the electrical operating conditions. The Omron connector is a DB9 type. MAGELiS (XBTZ974) to Omron Cable (RS-4) XBT MAGELiS Terminal PLC Omron 0 V SG SG9 0 V Transmission E TXD+ TXD A B 4 Rt 8 RD RD+ R Reception + V RXD+ R Rp Rp RXD 0 V Reception A' B' PG 8 Rt PG SD SD+ E Transmission 8 Connection of shielding to both cable ends depends on the electrical operating conditions. Rt: Link termination resistor (normally 0 Ω). NOTE: The Rp resistors (4.7 kω) are integrated in the XBT. 90 999 000 Schneider Electric All Rights Reserved /00
Wiring Diagrams MAGELiS (XBTZ970) to GE Fanuc Cable GE-FANUC SUB-D 9-pin male MAGELIS XBT SUB-D -pin male RxD RxD+ TxD TxD+ SG HTS 8 9 4 Shielding PG 4 A TxD+ B TxD A' RxD+ 8 B' RxD SG 8 RTS 4 3 CTS CTS /00 999 000 Schneider Electric All Rights Reserved 9
Dimensions Displays and Terminals XBTH Mounting Panel Cutout.0 0 0.49 7.4 0.3.3 83.8.8 0.8 7 0.4. 3.3 89. 4.0 0 () 0.4. 7.9 0 7. ± 0.0 84. ± 0.4 3. ± 0.0 90. ± 0.4 XBTP Mounting Panel Cutout.8.4 0.39 9.3 0.33 0 34. 8. 0.8 7.. 0.4 33.3..98 ().8 ± 0.0 34 ± 0.4 0.49. 9.9 3 9. ± 0.0 3 ±0.4 XBTE Mounting Panel Cutout.8 8 0.3 0.39 0.7 9 4 9 0.8 7 7.9 0.8 8. 7 7.97 0. () 7. ± 0.0 83 ± 0.4 0. 3. 9 0.43 ± 0.0 ± 0.4 XBTHM Mounting Panel Cutout.7 7.7 0.3 7. 0.3.8 90.4.8 0.8 7. 0.3.8.8 30 3.8 93.4 4.38.3 () 0.79 0.7 7.7 0.48. 7.9 0 7. ± 0.0 90.9± 0.4 3.7 ± 0.0 94 ± 0.4 Dual Dimensions inches mm () r = 0.08 0.4 in. ( 3. mm) 9 999 000 Schneider Electric All Rights Reserved /00
Dimensions Terminals with Graphic Screens XBTF0 0 Mounting Panel Cutout 3.9 8 0.8 7 0. 9.4 0.4.7 4.3 0.4 8. 0.4 08.3 8.7 0.3 0.43 () 8.3 ± 0.0 09 ± 0.4 9.7 ± 0.0 43 ± 0.4 XBTF03 0 Mounting Panel Cutout 3.37 8. 0.8 7 0.3.33 0.3.7 3..7 0.3 7.3 0.3.7 8..7 7.7 97.79 47 () 7.33 ± 0.0 8. ± 0.4.3 ± 0.0 3. ± 0.4 XBTF03/F04 Mounting Panel Cutout 3.3 84 0.8 7 0.7.4 0.3 7.8 308.3.8 0.3.9 0.3.8 84.3.8. 9 3.07 33 (). ± 0.0 8 ± 0.4.7 ± 0.0 309 ± 0.4 XBTF034 Mounting Panel Cutout 3.3 84 0.8 7 0.3 8.8 0.3.8 0.3.8 0.3.9 0.3.8 84.3.8. 9 8.74 (). ± 0.0 84.9 ± 0.4 8.3 ± 0.0 0.9 ± 0.4 Dual Dimensions inches mm () r = 0.08 0.4 in. ( 3. mm) /00 999 000 Schneider Electric All Rights Reserved 93
94 999 000 Schneider Electric All Rights Reserved /00