Operator dialogue terminals
|
|
|
- Lionel Logan
- 9 years ago
- Views:
Transcription
1 Magelis text displays and operator terminals Characteristics : page /43 References : pages /44 to /46 General Design of the XBT-H/P/E range of display units and terminals Range XBT-H XBT-P XBT/H/P/E display units and terminals available : - no operating system, - no protocol, - no application. XBT-L1000 XBT-E XBT-L1000 configuration software used with PC to : - select the XBT-H/P/E display unit or terminal, - select the protocol used, - design an application on screen, - simulate the functions with the control system, - download the application. PC XBT-L downloadable communication protocols : - operating system of downloadable products, - downloadable applications. - see page /4 for details. Application Pg 0 AUTOMATIC OPERATION Pg 1 MACHINE ADJUSTMENT Design : - of application pages, - of alarm pages. Pg 3 TEMPERATURE SPEED Pg 2 MAINTENANCE Pg 0 Pg 3 Pg 1 Pg 2 Entry : - Windows compatible software, - user-friendly, - WYSIWYG type entry, (what you see is what you get). Communication Display unit or terminal : Automatic execution of commands transmitted by the PLC. XBT-P Third party PLC PLC : Programming communication configured by dialogue table in PLC memory. Dialogue Table /42 Te
2 Magelis text displays and operator terminals General, presentation : page /42 References : pages /44 to /46 General General characteristics for the Magelis range Directive and/or Standard CE marking Meets the essential requirements of the European Electromagnetic Compatibility Directive 89/336/ EEC and the Low Voltage Directive 73/23/EEC Conforming to standards IEC , EN , UL 08, CSA C22-2 n 14 Product approvals UL File E164866, CSA File LR44087 Environment Subject Relevant Characteristics Standard Electrostatic discharges IEC Terminal not powered up 1 kv air discharge on front panel 8 kv by contact Terminal powered up 8 kv air discharge 6 kv by contact Electromagnetic field withstand IEC V/m 26 MHz to 1 GHz Fast transients IEC kv in series (capacitive coupling) 2 kv supply Electric surge IEC 2.4/E Between housing and I/O 1. kv ; 0. J Between isolated circuits 1.2 / 0 µs Between power supply wires kv ; 0. J Between housing and power supply 1.2 / 0 µs Brief power cuts IEC 1131 Cuts of < 10 ms duration of cut : 1s Dielectric withstand IEC For 24 V products 00 V d.c. between circuits and For 11 V products 120 V a.c. housing For 230 V products 200 V a.c. Leakage current < ma Degree of protection IEC 29 Keypad/Front panel IP 6, NEMA 4, UL 4 NF C UL Rear enclosure IP 20 Temperature Operation (LCD and fluorescent) C Storage (LCD only) C Storage (Fluorescent only) C Mechanical Type of mounting and fixing Material Flush-mounted with 4 or 6 spring clamps (supplied) (on panel 1 to 6 mm thick) Enclosure : Polyphenylene oxide with 10% fibreglass (PPO GFN1 SE1) Keypad : Anti-UV coated (Autoflex EB AG) hardened polyester Vibration resistance IEC to 10 Hz sweep 2 to 11.2 Hz low amplitude : 1 mm 11.2 to 10 Hz low acceleration 1 g Duration 2 h at resonance frequencies Electrical Power supply Voltage 24 V d.c Voltage limits 18 to 30 V d.c. Ripple % maximum Consumption 10 W (20 W for XBT-E014 and XBT-E016 Operating characteristics Different for each product - see detailed MAGELIS catalogue (ICC 1490). Te /43
3 ENTER HOME ESC SHIFT 1 PRINT MOD -1 SYST MENU ALARM ENTER DEL HOME ESC SHIFT 1 PRINT MOD -1 SYST MENU ALARM ENTER Operator dialogue terminals MAGELIS Text display and operator interface terminals Multi-protocol communications, multilingual operation, 24 V d.c. References MAGELIS XBT-H text displays XBT-H Back-lit LCD display, 2 x 20 characters, 200 messages XBT-H Back-lit LCD display, 2 x 20 characters, 4 function keys, XBT-H service key, 200 messages Back-lit LCD display, 2 x 20 characters, service keys, XBT-H messages Fluorescent display, 2 x 20 characters, 200 messages XBT-H Fluorescent display, 2 x 20 characters, 4 function keys, XBT-H service key, 200 messages Fluorescent display, 2 x 20 characters, service keys, XBT-H messages Fluorescent display, 2 x 20 characters, service keys, XBT-H printer link, 200 messages MAGELIS XBT-P operator terminals XBT-P Back-lit LCD display, 2 x 20 characters, 8 function keys, XBT-P services keys, 400 messages Back-lit LCD display, 2 x 20 characters, 12 function keys, XBT-P service keys, Num keypad, 400 messages Back-lit LCD display, 2 x 20 characters, 12 function keys, XBT-P service keys, Num keypad, printer link, 400 messages Fluorescent display, 2 x 20 characters, 8 function keys, XBT-P service keys, 400 messages Fluorescent display, 2 x 20 characters, 12 function keys, XBT-P service keys, Num keypad, 400 messages Fluorescent display, 2 x 20 characters, 12 function keys, XBT-P service keys, Num keypad, printer link, 400 messages MAGELIS XBT-E advanced operator terminals XBT-E Back-lit LCD display, 2 x 40 characters, 24 function keys, XBT-E Back-lit LCD display, 2 x 40 characters, 24 function keys, XBT-E Back-lit LCD display, 4 x 40 characters, 24 function keys, XBT-E Back-lit LCD display, 4 x 40 characters, 24 function keys, XBT-E Fluorescent display, 2 x 40 characters, 24 function keys, XBT-E Fluorescent display, 2 x 40 characters, 24 function keys, XBT-E Fluorescent display, 4 x 40 characters, 24 function keys, XBT-E Fluorescent display, 4 x 40 characters, 24 function keys, XBT-E Message display Operator terminal Operator terminal XBT-H XBT-P XBT-E ,3 183,8,8 89,6 6, ,1 133,3 6, /- 0.,4 8, 234, , ,8 182, 7 ABC DEF GHI DEL JKL MNO PQR 4 6 STU VWX YZ / 0 202, 6, , /44 Te
4 MAGELIS Text display and operator interface terminals Multi-protocol communications, multilingual operation, 24 V d.c. References Programming software and PC connection cables Magelis terminal programming software XBT-L Requires Windows (see detailed MAGELIS catalogue ICC 1490 for further details) Cable, Magelis to PC (9-pin male) XBT-Z for downloading program (RS232) Cable, Magelis to PC (2-pin female) XBT-Z for downloading program (RS232) Cable, Magelis to PC (2-pin male) XBT-Z for downloading program (RS232) Communication protocol drivers Allen Bradley SLC/PLC (DF1) protocol driver XBT-L1AB Modicon Micro/984/AEG (Modbus/JBus) protocol driver XBT-L1MOD Omron CV/CQM/C200 (SYSMAC) protocol driver XBT-L1OMR Siemens Simatic S (3964R & AS11) protocol driver XBT-L1SIE Modicon TSX and Telemecanique (Uni-Telway) protocol driver XBT-L1UTW Technical documentation Magelis technical operating manual, A format, English XBT-X000EN Magelis technical operating manual, A format, German XBT-X000DE Magelis technical operating manual, A format, Spanish XBT-X000ES Magelis technical operating manual, A format, French XBT-X000FR Magelis technical operating manual, A format, Italian XBT-X000IT Cables and connection accessories for PLCs (see selection guide in MAGELIS catalogue) Cable, Magelis to third party PLC XBT-Z (requires XGVSZ connector for specific PLC) Cable, Magelis to Siemens PLC XBT-Z (requires XGVSZ connector for specific PLC) SUB-D connector, 9-pin female XGV-SZ SUB-D connector, 9-pin male XGV-SZ SUB-D connector, 1-pin female XGV-SZ SUB-D connector, 1-pin male XGV-SZ SUB-D connector, 2-pin female XGV-SZ SUB-D connector, 2-pin male XGV-SZ Te /4
5 MAGELIS Text display and operator interface terminals Multi-protocol communications, multilingual operation, 24 V d.c. References Connection accessories specific to Modicon TSX and Telemecanique PLCs Cable, Magelis to Modicon TSX Nano, Micro & Preniun PLC XBT-Z Cable, Magelis to TSXSCA62 Uni-Telway junction box XBT-Z Cable, Magelis to TSXSCM21.6 Uni-Telway module XBT-Z Cable, Magelis to TSXSCG1161 Uni-Telway module for TSX17 XBT-Z Cable, Magelis to TSXLES64 plug on Series 7 CPU module XBT-Z Cable, Magelis to TSX17 programming port XBT-Z Cable, 100 metres of RS48 double sheided twisted pair, TSX-CSA Uni-Telway TSX 07/37/7 terminal port expansion & connection unit TSX-PACC T-junction box for Uni-Telway module TSX-SCA channel junction box for Uni-Telway bus TSX-SCA General accessories for the MAGELIS range Screw terminal connector, current loop/current loop, top hat mounting XBT-Z Screw terminal connector, current loop/current loop, 'c' rail mounting XBT-Z Interface Unit, current loop to RS232, SUB-D connector XBT-Z Interface Unit, current loop to RS232, screw terminals XBT-Z V d.c., 1A power supply, 110 V a.c./240 V a.c. input voltage TBX-SUP Cable, Magelis to Printer, serial link XBT-Z Magelis labels for 4 function keys (12 labels) XBL-YH Magelis labels for 8 function keys (24 labels) XBL-YP Magelis labels for 12 function keys (24 labels) XBL-YP Magelis labels for 24 function keys (32 labels) XBL-YE /46 Te
6 PLC connection cables, protocol drivers Selection guide PLC PLC range Connection details Magelis cable and Protocol Protocol Magelis manufacturer and/or model (PLC hardware) connection accessories name product status or brand (see pages /4 and /46) reference Allen Bradley PLC CPU Channel 0 XBT-Z900 XGV-SZ220 DF1 XBT-L1AB01 Master SLC00 CPU comms. port XBT-Z900 XGV-SZ0910 DF1 XBT-L1AB01 Master April S A000/A7000 JBU200 comms. module XBT-Z900 XGV-SZ210 JBus XBT-L1MOD01 Master S A2000/A3000 CPU comms. port XBT-Z900 XGV-SZ210 JBus XBT-L1MOD01 Master PB400 XBT-Z900 XGV-SZ210 JBus XBT-L1MOD01 Master SMC XBT-Z900 XGV-SZ210 JBus XBT-L1MOD01 Master Modicon 984 range 984 Modbus XBT-Z900 XGV-SZ0920 Modbus XBT-L1MOD01 Master Omron CQM1 Programming port XBT-Z900 XGV-SZ0920 SYSMAC XBT-L1OMR01 Master C200HX Programming port XBT-Z900 XGV-SZ0920 SYSMAC XBT-L1OMR01 Master CV range Programming port XBT-Z900 XGV-SZ0920 SYSMAC XBT-L1OMR01 Master Siemens SIMATIC S-90U CPU comms. port XBT-Z909 XBT-Z939 AS11 XBT-L1SIE01 Master SIMATIC S-9U Comms. port XBT-Z900 XGV-SZ R XBT-L1SIE01 Master SIMATIC S-9U Programming port XBT-Z909 XBT-Z939 AS11 XBT-L1SIE01 Master SIMATIC S-100U Comms. module XBT-Z900 XGV-SZ R XBT-L1SIE01 Master SIMATIC S-100U Programming port XBT-Z909 XBT-Z939 AS11 XBT-L1SIE01 Master SIMATIC S-11U CP2 comms. module XBT-Z900 XGV-SZ R XBT-L1SIE01 Master SIMATIC S-11U Programming port XBT-Z909 XBT-Z939 AS11 XBT-L1SIE01 Master SIMATIC S-13U CP2 comms. module XBT-Z900 XGV-SZ R XBT-L1SIE01 Master SIMATIC S-13U Programming port XBT-Z909 XBT-Z939 AS11 XBT-L1SIE01 Master Telemecanique TSX07 (Nano) Programming port XBT-Z968 Uni-TE (V2) XBT-L1UTW01 Slave & Modicon TSX TSX37/7 (Micro/Premium) CPU comms. XBT-Z968 Uni-TE (V2) XBT-L1UTW01 Slave TSX37/7 CPU comms. ACC01 CSA*** SCA62 XBT-Z908 Uni-TE (V2) XBT-L1UTW01 Slave TSX37/7 PCMCIA SCPCU4030 SCA62 XBT-Z908 Uni-TE (V2) XBT-L1UTW01 Slave TSX17 Programming port XBT-Z98 Uni-TE (V1) XBT-L1UTW01 Master TSX17 SCG1161 comms. module XBT-Z928 Uni-TE (V1) XBT-L1UTW01 Slave TSX47/67/87/107 CPU comms. LES64 XBT-Z948 Uni-TE (V1) XBT-L1UTW01 Slave TSX47/67/87/107 CPU comms. LES64 CSD100 SCA62 XBT-Z908 Uni-TE (V1) XBT-L1UTW01 Slave TSX47/67/87/107 SCM2116 comms. module XBT-Z918 Uni-TE (V1) XBT-L1UTW01 Slave Note : This list is continuously being updated. Please check with Telemecanique Coventry (01203) 4162 for an update. Te /47
MAGELiS Operator Terminals
Push Buttons and Operator Interface Specifier s Guide MAGELiS Operator Terminals File 900 CONTENTS Schneider Electric Brands Description Page Product Description................................................
HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB
Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis
Display units With alphanumeric screen
Display units With alphanumeric screen Compact display units Display Capacity lines, 0 characters 4 lines, 0 characters Back-lit LCD, green Back-lit LCD, green Back-lit LCD, 3 colours: green, orange, red
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
SIMATIC Flat Panel Monitors
Product Data Sheet The Flat Panels are rugged industry-standard LCD monitors. Design of front panels: - 12", 15", 17" and 19" TFT Touch - 12" and 15" TFT Key Installation: - They are equally suited to
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
NX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
Communication Unit 560CMU05 Data sheet
RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
AC3200 INTELLIGENT BROADBAND AMPLIFIER
Kari Mäki 9.4.2013 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Low Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series
Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020
Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020 Built-in Dupline channel generator PROFIBUS-DP slave according to EN 50 170 Certified by the PNO PROFIBUS-DP communication
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH
ENGLISH EMOSAFE EN-100 Product Data Sheet Network Isolators for PCB assembly November 2013 1 GENERAL DESCRIPTION The EMOSAFE EN-100 Network Isolator interrupts all galvanically conducting connections (conductors
Magelis XBT N/R/RT 33003962 11/2011. Magelis XBT N/R/RT. Compact Display Units User Manual 11/2011 33003962.03. www.schneider-electric.
Magelis XBT N/R/RT 33003962 11/2011 Magelis XBT N/R/RT Compact Display Units User Manual 11/2011 33003962.03 www.schneider-electric.com The information provided in this documentation contains general descriptions
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3
Contents Moxa Technical Support Team [email protected] 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...
EA7-T8C EA7-T10C EA7-T12C EA7-T15C
The new Generation of Touch Panels with ambitious image presentation and integrated operating function With the C-more series, featuring STN and TFT touch screens, AutomationDirect now provides the best
6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.
6AV3617-1JC30-0AX1 Page 1 Product data sheet 6AV3617-1JC30-0AX1 OPERATOR PANEL OP17/DP12 LC DISPLAY, BACKLIT LED 4X20/8X40 LINESXCHARACTERS SIMATIC S5, 505, S7, M7, NATIVE DRIVERS, PROFIBUS-DP 12 MBAUD,
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
s!nus-elektrotechnikai bt. Industrial IT & Automation
USER MANUAL s!nus-elektrotechnikai bt. USB/PPIM+ Siemens S7-200 USB/PPI Multi-Master Cable USB/RS485 Isolated For all PPI-Bus System Summary: USB / PPIM + is the PPI Multi-Master programming Cable which
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 6 A 80. Multi-function and mono-function timer range - Multi-function & multi-voltage 80. - ON delay, multi-voltage 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN
MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
Pop. Parker operator panels. Pop CANopen. Compax3 I21T11 CANopen. with integrated axis. standalone SMH/MH. CANopen. digital inputs & outputs
Pop Compax3 powerplmc C1x with integrated axis Compax3 I21T11 powerplmc-e20 standalone SMH/MH digital inputs & outputs servo motors PIO I/O Pop Parker operator panels 2 3 Automation Control and Monitoring
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK Field busses are industrial control systems using Programmable Logic lers (PLC) to control and manage field devices found in industrial environments. The communication
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
MI4 - Operator Panel : Engineering
MI4 - Operator Panel : Engineering MI4 - Operator Panel : Engineering Overview MI4 Text Operator Panel MI4 Graphic Operator Panel MI4 Touch Operator Panel Communication modules Accessories MI4-CFG-1 Engineering
FN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
Capacitor Protection Relay SPAJ 160 C. Product Guide
Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features One-, two- and three-phase overload stage with definite time characteristic One-, two- and three-phase
Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C
Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS
Universal Serial Bus (USB) to DH-485 Interface Converter
Installation Instructions Universal Serial Bus (USB) to DH-485 Interface Converter Catalog Number 1747-UIC Contents Overview..................................................3 Computer and Operating System
Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing
Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed. ENHANCED GRAPHIC LCD The
key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
ATA TO IDE INTERFACE PC CARD DRIVES
ATA TO IDE INTERFACE PC CARD DRIVES 1 Front slot Support Type I/II/III ATA Flash, ATA HDD, Compact Flash Cards(an adaptor required) Operating Temperature: 0 o C- 70 o C 1 real slot Support Type I/II/III
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Specifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out
SIMATIC S7-200 EM223 Digital Combination Modules EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out Table 1 Specifications for EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out EM223 2VDC In/Out 6ES7 2231BF200XA0
My first Hirschmann: The SPIDER family of switches.
My first Hirschmann: The SPIDER family of switches. Large selection of entry level switches Compact design Simple rail installation Industry standard 24 V supply voltage Plug & Play gets you up and running
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
mecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)
Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2) Legal notice: Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are
Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.
Preliminary TECHNICAL DATASHEET #TDAX020700 HYDRAULIC VALVE CONTROLLER 24 I/O 5 Analog and 6 Digital Inputs 1 Temperature Sensor and 1 RPM Sensor Interface 2 PWM Inputs 6 Proportional and 4 ON/OFF Current
LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: http://www.siemens.com/simatic/ printmaterial
Siemens AG 010 / / SIPLUS basic versions /5 SIPLUS Pure versions /8 analog expansion modules /9 SIPLUS expansion modules Brochures For brochures serving as selection guides for SIMATIC products refer to:
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following
SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules
SIMATIC S7-300 and M7-300 Programmable Controllers Module Specifications Reference manual This manual is part of the following documentation packages with order nos: S7 300 Programmable Controller: 6ES7
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4
Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4 eng May 2007 35009581_02 2 335009581 02 May 2007 Document Set Document Set At a Glance This documentation
SIMATIC IPC477D 1/5. Copyright Siemens AG 2014
Product data sheet (Panel PC): The powerful embedded Panel PC maintenance-free with versatile configuration Embedded PC platform with extremely high industrial compatibility for demanding tasks in the
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
Using installed Fieldbus Wiring to carry Ethernet Communications
Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading
CP 342-5. Page 1342 Mar 2008 Siemens ITS
CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7 communication