PowerWAVE EL. Designed to deliver complete emergency lighting protection

Similar documents
PowerGem Pro Uninterruptible Power Supply

Phase Modular Finally the benefits of Modular ups are for all

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

MAJORSINE Power Inverter

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Technical Data. back-up time in minutes 100% load % load

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

RIELLO ELETTRONICA. Master HP

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Thyristor-controlled power supplies and battery chargers

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

VISION UPS UPS PRODUCT CATALOGUE

Uninterruptible power supplies Meissner. Efficient and reliable backup where electricity is critical to you

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

UNINTERRUPTIBLE POWER SUPPLY (UPS)

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

Uninterruptible Power Supply

The UPS for the highest security in industry and data centres

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

4.0 UPS dedicated to ICT for unmatched energy savings

LAP ENERGIA PARA DATACENTERS

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

10000HXL31/15000HXL31/20000HXL31

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

MPR-Systems. Mini Power Racks 1200 W W

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Online UPS. PowerWalker VFI 1000R/1U

Technical Specification Kohler PW 5000/TP

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

Assembled in Florida, USA.

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

BB800 Off-Grid Solar System

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

User Manual 1K/2K/3K Online UPS

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Stroom voor elke toepassing

Liebert NXC from 10 to 200 kva

Chloride 80-NET from 60 to 500 kw. Secure Power for Mission Critical Applications

User Manual PowerWAVE 8000DPA RI

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

User s Manual Before using the inverter, you need to read and save the safety instructions.

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Specification Requirements DBL 700MX and 1000MX Series UPS

TOSHIBA G /100/160/225 kva

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

UPS system for emergency lighting and smoke extraction

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

Ambient Temperature In Range Probe X

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

TLE Series UPS kw for best-in-class multi-mode operating efficiency

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Technical Specification

USER MANUAL Online UPS 1K/2K/3K

Telephone- and leased line modem for industrial applications TD-36

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Electronic Control Devices The European Product Catalogue 2007

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

SNMP Web Management. User s Manual For SNMP Web Card/Box

is then retained absolutely without interruption.

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

GAMATRONIC ELECTRONIC INDUSTRIES LTD.

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Technical data UNIBLOCK UBSF

Manual. Solar Fountain Mobile Phone Charger

Single Output Switching Power Supply

SECTION STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Rack mounted telephone- and leased line modem for industrial applications

Transcription:

PowerWAVE EL Designed to deliver complete emergency lighting protection

PowerWAVE EL Efficient power for emergency lighting and safety equipment The PowerWAVE EL series addresses the need for a range of high performance static inverters, manufactured using state of the art technology to give your operation the peace of mind it needs. For more information call 01256 386700 or visit www.upspower.co.uk PowerWAVE EL Designed to the latest European EN 50171 True double conversion and PWM technology Inverter stage output galvanic isolation transformer included Capable of 120% continuous overload to meet European Emergency Lighting regulations Parallel mode operation (optional) (hot standby, redundant, symmetric parallel) Large charger for faster recharge of batteries Maintenance bypass (for complete isolation of the inverter during maintenance) Unique inverter design to suit high inrush lighting loads Bypass to load (change-over mode) user selectable LCD panel providing accurate detailed information about load, batteries and inverter with advanced diagnostics RS232 and dry contacts for communication and remote monitoring Common applications Emergency lighting systems Central power supply systems Fire alarm and safety systems System and battery test function Hospital and medical systems Cinemas and entertainment venues Retail Uninterruptible Power Supplies Ltd, Woodgate, Bartley Wood Business Park, Hook, Hampshire RG27 9XA Tel: 01256 386700 Fax: 01256 386701 Email: sales@upspower.co.uk

PowerWAVE EL 100XA Series High Performance Static Inverter (500VA to 3000VA) Wall-mounted & standalone options Allows for an internal self-contained battery system capable of supplying standard emergency lighting of 3 hour autonomies Fully encapsulated product for lower rated requirements Single Phase & Technical speciication Model EL1005XA EL1012XA EL1030XA Power Rating VA / W 500 / 400 1250 / 1000 3000 / 2400 Power Factor 0.8 / Tolerance 230VAC Single phase/184v ~ 285V +5% Max. RFI EN50091-2 CLASSA 230VAC Single phase Stability Changeover mode +10% / Battery mode +3% Recovery Time After step load 0-100%. Max. 20ms. Tolerance +1% in battery mode >97% Short CircuitProtection Electronic short circuit 120% continuous,150% alarm load Sealed lead aid maintenance free Number of 12V Blocks (Internal) 4 4 4or 8 Float Charging 54VDC 54VDC 54VDC End of Discharge 42VDC 42VDC 42VDC Battery Ambient Temperature 20 C 20 C 20 C Double Pole DC Circuit Breaker Automatic / Smart Battery Management Serial Communication Drycontacts plus RS232 Optional monitoring & shutdown / optional SNMP module IP21 Ambient Operating Temperature / Altitude 0 C to 40 C / <1000m above sea level Standard Emergency Lighting EN50171 Acoustic Noise at 1m Distance <56 dba Dimensions (mm) W x D x H 750 x 250 x 850 750 x 250 x 1250 750 x 400 x 1250

PowerWAVE EL 100 Series Single Phase & Online Static Inverter (4kVA to 12kVA) Solution for higher power, single phase loads Galvanic isolation transformer at the inverter stage Technical speciication Model EL104 EL105 EL106 EL108 EL110 EL112 Power Rating kva/kw 4 / 2.8 5 / 3.5 6 / 4.2 8 / 5.6 10/7 12.5 / 8.75 Power Factor 0.7 / Tolerance, +/- 15% By-pass +/- 5% Max RFI EN50091-2 Class A Stability Static (balanced load) +/-1%, Static (unbalanced load) +/-2%, Dynamic (step load 0-100%) +/-5% Recovery Time After step load 0-100% max. 20ms Tolerance Line synchronised +/- 1% / free running +/- 0.2% >87-91% Short Circuit Protection Electronic short circuit 120% continuous, 150% load 10min. 180% 1min, 200% for 1 sec Total Harmonic Distortion (THD) Linear Load <3% / non linear load (75% NP and CF 3:1) <5% Sealed Lead Acid Maintenance Free Number of 12V Blocks 16 18 20 Float Charging 216Vdc 243Vdc 270Vdc End of Discharge 160Vdc 180Vdc 200Vdc Battery Ambient Temperature 20 C Circuit breaker Automatic battery test once a week Serial Communication Dry contacts plus RS232 T-Mon standard / SNMP module optional IP41 Ambient Operating Temperature / Altitude 0 C to 40 C / <1000m (above sea level) Standard Emergency Lighting EN 50171 Acoustic Noise at 1m distance <56 dba Weight (kgs) 85 95 110 125 150 155 Dimensions (mm) w x d x h 500 x 300 x 1220

PowerWAVE EL 200 Series Three Phase & Single Phase Static Inverter (10kVA to 30kVA) Solution for higher power, three-phase loads Galvanic isolation transformer at the inverter stage Technical speciication Model EL210 EL215 EL220 Power Rating kva/kw 10 / 8 15 / 12 20 / 16 Power Factor 0.8 / Tolerance 230/400 VAC 3phase, 4wires, +ground, +/- 15% By-pass +/- 5% Max RFI EN50091-2 Class A Stability Static (balanced load) +/-1%, Static (unbalanced load) +/-2%, Dynamic (stop load 0-100%) +/-5% Recovery Time After step load 0-100% max. 20ms Tolerance Line synchronised +/- 1% / free running +/- 0.2% >87-91% Short Circuit Protection Electronic short circuit 120% continuous, 150% load 10min. 180% 1min, 200% for 1 sec Total Harmonic Distortion (THD) Linear Load <3% / non linear load (75% NP and CF 3:1) <5% Sealed Lead Acid Maintenance Free Number of 12V Blocks 30 Float Charging 405 End of Discharge 300VDC Battery Ambient Temperature 20 C Circuit breaker Automatic battery test once a week Serial Communication Dry contacts plus RS232 T-Mon standard / SNMP module optional IP41 Ambient Operating Temperature / Altitude 0 C to 40 C / <1000m (above sea level) Standard Emergency Lighting EN 50171 Relative Humidity 90% max (non-condensing) Acoustic Noise at 1m distance <56 dba Weight (kgs) 200 210 240 Dimensions (mm) w x d x h 520 x 715 x 1170

PowerWAVE EL 300 Series Three Phase & Static Inverter (10kVA to 160kVA) Solution for higher power, three-phase loads Galvanic isolation transformer at the inverter stage Technical speciication Model EL310 EL315 EL320 EL325 EL330 EL340 EL360 EL380 EL3100 EL3120 EL3160 Power Rating kva/kw 10 / 8 15 / 12 20 / 16 25 / 20 30 / 24 40 / 32 60 / 48 80 / 64 100 / 80 120 / 96 160 / 128 Power Factor 0.8 / Tolerance 230/400 VAC three phase, 4wires, +ground, +/- 15% By-pass 230/400 VAC three phase +/- 5% Max RFI EN50091-2 Class A 230/400 VAC three phase Stability Static (balanced load) +/-1%, Static (unbalanced load) +/-2%, Dynamic (stop load 0-100%) +/-5% Recovery Time After step load 0-100% max. 20ms Tolerance Line synchronised +/- 1% / free running +/- 0.2% >87-91% Short Circuit Protection Electronic short circuit 120% continuous, 150% load 10min. 180% 1min, 200% for 1 sec Total Harmonic Distortion (THD) Linear Load <3% / non linear load (75% NP and CF 3:1) <5% Sealed Lead Acid Maintenance Free Number of 12V Blocks 30 Float Charging 405 End of Discharge 300VDC Battery Ambient Temperature 20 C Circuit breaker Automatic battery test once a week Serial Communication Dry contacts plus RS232 T-Mon standard / SNMP module optional IP41 Ambient Operating Temperature / Altitude 0 C to 40 C / <1000m (above sea level) Standard Emergency Lighting EN 50171 Relative Humidity 90% max (non-condensing) Acoustic Noise at 1m distance <56 dba <60 dba <65 dba Weight (kgs) 260 276 332 494 494 572 630 780 820 970 1160 Dimensions (mm) w x d x h 520 x 715 x 1170 590 x 860 x 1425 730x840x1425 1120 x 840 x 1675 1215 x 910 x 1755 UPS 739-01-01 PowerWAVE EL 27/05/15