The Electrocardiogram and Heart Sounds

Similar documents
Exercise, the Electrocardiogram, and Peripheral Circulation

Data Analysis 1. Click the 2-Cursor icon (Figure HH-7-L1) so that two blue vertical lines appear over the recording window.

Small Animal Respiratory Exchange Ratio (RER)

Electrocardiogram and Heart Sounds

Biology 347 General Physiology Lab Advanced Cardiac Functions ECG Leads and Einthoven s Triangle

Experiment HE-6: Breath by Breath Measurement of Respiratory Exchange Ratio (RER)

Experiment MP-1: Electromyogram (EMG) Activity and Muscle Strength

iworx Sample Lab Experiment HN-2: Stretch Receptors and Reflexes

Activity 4.2.3: EKG. Introduction. Equipment. Procedure

Project 4.2.1: Heart Rate

#AS148 - Automated ECG Analysis

Lab 3: Introduction to Data Acquisition Cards

Evaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS

Electrocardiography I Laboratory

Updated Application Note AS-199 Impedance Cardiography and Pre-ejection Period

Evaluation copy. Analyzing the Heart with EKG. Computer

Monitoring EKG. Evaluation copy

COULBOURN HUMAN MEASUREMENT SYSTEM SCRIPT-DRIVEN IMAGERY SOFTWARE FOR THE PORTABLE PHYSIOLOGY PLATFORM USERS GUIDE (HMS-300-P3)

1. Installing The Monitoring Software

Biopac Student Lab BASIC TUTORIAL. BIOPAC Systems, Inc. Version 3.0.3

Introduction Configuring Your HP Mouse Batteries Replacing the Batteries Mouse Sensor Technology Navigating the HP Mouse Control Center

Muscle Physiology. Lab 5. Human Muscle Physiology

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Mbox Basics Guide. Version 6.7 for LE Systems on Windows XP or Mac OS X. Digidesign

ADINSTRUMENTS. making science easier. LabChart 7. Student Quick Reference Guide

Experiment HE-8: Regulation of Body Temperature and the Respiratory Exchange Ratio (RER)

The EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to.

5. Tutorial. Starting FlashCut CNC

Human ECG Laboratory Experiment By

HOW TO TRANSFER FILES BETWEEN EEN IDL7000 PVR AND USB2 DEVICE

Getting Started on the Computer With Mouseaerobics! Windows XP

Biopac Student Lab Lesson 6 ELECTROCARDIOGRAPHY (ECG) II Introduction. Rev

Soundcraft Signature MTK Recording Guide

Lab 4 - Data Acquisition

Dash 18X / Dash 18 Data Acquisition Recorder

Connecting External Resources

BrainMaster tm System Type 2E Module & BMT Software for Windows tm. Helpful Hints

MED-AFEs Design Reference Manual

SnagIt Add-Ins User Guide

SW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards

Start Here. BrightLink Interaction. 1 Connect your computer and turn on the projector

Lab 1: Full Adder 0.0

DCM555 - Data Communications Lab 8 Time Division Multiplexing (TDM) Part 1 - T1/DS1 Signals

Dash 8Xe / Dash 8X Data Acquisition Recorder

BrightLink Pro. Quick Reference. BrightLink Interaction. BrightLink Pro Features. 1 Turning on and Calibrating the Projector

EPSON Stylus. Start Here

Using USB Flash Drives

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

RLC Series Resonance

Introduction to Microsoft Word 2003

ISP Engineering Kit Model 300

HP Advanced Wireless Docking Station. User Guide

Creating a Poster in PowerPoint A. Set Up Your Poster

Audio-Technica AT-LP60-USB, AT-LP120-USB, AT-LP240-USB & AT-LP1240-USB Turntables. Software Guide

Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation

Manual. Sealer Monitor Software. Version

Macintosh System OSX #1

Creating tables of contents and figures in Word 2013

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

Polar Cardio GX: Help Topics

RFID Logger Software User Manual Rev 1.0

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

Loss of data can happen in many ways. One of the most common causes is hard drive failure. Hard drives can die without warning.

12/15-Lead ECG Protocol approved October 2005 revised October 2008

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

USB Flash Drive. The New Age of Data Storage Future. 1990s

Windows Movie Maker 2012

4. Do you have a VGA splitter ( Y Cable)? a document camera?

such as USB drives, connected servers, DVDs, CDs, configure file labels, and the information that appears in the Finder window sidebar.

Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version

Guide for Remote Control PDA

Capacitive Touch Lab. Renesas Capacitive Touch Lab R8C/36T-A Family

CATIA Basic Concepts TABLE OF CONTENTS

OS X LION SET UP THE SYSTEM

MICROSOFT OUTLOOK 2010 WORK WITH CONTACTS

Connecting to the Internet

PIGCHAMP MOBILE. PigCHAMP Knowledge Software. Installation Guide for Mobile Units

DAS202Tools v1.0.0 for DAS202 Operating Manual

Interactive Whiteboard Functionality Overview Choosing Pen Style Erasing / Modifying Writing Undo / Redo

Use only a shielded parallel interface cable that is IEEE 1284-compliant and/or a USB cable that is no longer than 6 feet long (1.8 meters).

Task Card #2 SMART Board: Notebook

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

Getting to Know Your Mobile Internet Key

Heart Rate Data Collection Software Application User Guide

Thank you for purchasing Qwizdom Remotes.

Trace.Net OTDR Test Management Software User s guide

M8 basics. Setting Up Your M8 Android Box Remote Essentials Using Your M8 Android Box Setting up Wireless... 6

Psychology equipment

Winlead Dialer Software Users Manual Addendum 3 Installing Winlead Dialer Software on the Windows 2000 System

Table of Contents. 0. Internet Connectivity Assumptions Identifying the Network Wall Jack Identifying the Ethernet Cable..

ScanShell.Net Install Guide

AMBULATORY BLOOD PRESSURE MONITORING QUICK START GUIDE

QUICK START GUIDE Bluetooth Cordless Hand Scanner (CHS)

LCD MONITOR TOUCH PANEL DRIVER 2 OPERATION MANUAL. for Mac. Version 1.0 PN-L703A/PN-70TA3/PN-L703B/PN-70TB3/PN-L603A/PN-60TA3/PN-L603B/PN-60TB3

TouchKit Software User manual for Windows 7 Version:

SMART Board Software for Macintosh FAQ

Contents. ST9612 Model WIC Printer. Get the original printer s information. Edited 11/04/15

BLU Vivo 4.3 User Manual

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

Transcription:

iworx Physiology Lab Experiment Experiment HH-2 The Electrocardiogram and Heart Sounds Note: The lab presented here is intended for evaluation purposes only. iworx users should refer to the User Area on www.iworx.com for the most current versions of labs and LabScribe2 Software. iworx Systems, Inc. www.iworx.com iworx Systems, Inc. 62 Littleworth Road, Dover, New Hampshire 03820 (T) 800-234-1757 / 603-742-2492 (F) 603-742-2455 LabScribe2 is a trademark of iworx Systems, Inc. 2013 iworx Systems, Inc.

Experiment HH-2: The Electrocardiogram and Heart Sounds Background Blood enters the arterial system from the ventricles of the heart in a pulsatile manner. However, when blood is leaving the arterial system through the capillaries, it flows in a continuous manner. Between contractions, when the heart is relaxed and blood is not being pumped into the arterial system, there is still enough pressure in the arterial system to move blood along the arteries. The pressure in the arterial system exists because the elasticity of the arteries allow them to distend and recoil and function as a pressure reservoir. When the ventricles contract, the pressure of the blood inside the ventricles increases to close the atrioventricular valves. Further contraction increases the ventricular pressure until it exceeds the arterial pressure. At this point, when the arterial pressure is at its lowest point during the cardiac cycle (called diastolic pressure) the semilunar valves are forced open, and blood flows into the artery. Blood entering the arterial system inflates the arteries a little and increases blood pressure to a maximum, which is the systolic pressure. In this lab you will record the ECG from a subject and listen to the characteristic lub-dub heart sounds. The lub sound occurs during the early phase of ventricular contraction and is produced by closing of the atrioventricular valves, which prevents blood flow into the atria. When the ventricles relax, the blood pressure drops below what is in the artery and the semilunar valves close, producing the dub sound. HH-2-1

Experiment HH-2: The Electrocardiogram and Heart Sounds Note this lab uses a manual or electronic stethoscope so that students can get gain an understanding for using an external stethoscope for listening to the heart. If you would like to use the Heart Sounds microphone instead please refer to Lab HH-8 Auscultation. Equipment Required PC or Mac Computer IXTA data acquisition unit USB cable IXTA power supply C-ISO-B3G ECG cable and electrode lead wires EM-220 Event marker Stethoscope Alcohol swabs Disposable ECG electrodes IXTA Setup 1. Place the IXTA on the bench, close to the computer. 2. Check Figure T-1-1 in the Tutorial Chapter for the location of the USB port and the power socket on the IXTA. 3. Check Figure T-1-2 in the Tutorial Chapter for a picture of the IXTA power supply. 4. Use the USB cable to connect the computer to the USB port on the rear panel of the IXTA. 5. Plug the power supply for the IXTA into the electrical outlet. Insert the plug on the end of the power supply cable into the labeled socket on the rear of the IXTA. Use the power switch to turn on the unit. Confirm that the red power light is on. Start the Software 1. Click on the LabScribe shortcut on the computer s desktop to open the program. If a shortcut is not available, click on the Windows Start menu, move the cursor to All Programs and then to the listing for iworx. Select LabScribe from the iworx submenu. The LabScribe Main window will appear as the program opens. 2. On the Main window, pull down the Settings menu and select Load Group. 3. Locate the folder that contains the settings group, IPLMv4Complete.iwxgrp. Select this group and click Open. 4. Pull down the Settings menu again. Select the ECG-Heart Sounds-LS2 settings file from Human Heart. HH-2-2

5. After a short time, LabScribe will appear on the computer screen as configured by the ECG- Heart Sounds-LS2 settings. 6. For your information, the settings used to configure the LabScribe software and the IXTA unit for this experiment are programmed on the Preferences Dialog window which can be viewed by selecting Preferences from the Edit menu on the LabScribe Main window. 7. Once the settings file has been loaded, click the Experiment button on the toolbar to open any of the following documents: Appendix Background Labs Setup (opens automatically) ECG Cable and Event Marker Setup 1. Locate the C-ISO-B3G ECG cable and electrode lead wires (Figure HH-2-L1), and EM-220 event marker (Figure HH-2-L2), in the iworx kit. 2. Plug the DIN8 connector to the EM-220 event marker into the Channel A9 input on the rear of the IXTA (Figure HH-2-L3). 3. Insert the connector on the end of the C-ISO-B3G ECG cable into the iwire 1 input on the front of the IXTA. 4. Insert the connectors on the red, black, and green electrode lead wires into the matching sockets of the ECG cable. 5. Instruct the subject to remove all jewelry from their wrists and ankles. Another option is to use the area just under each clavicle which will give a better recording. 6. Use an alcohol swab to clean a region of skin on the inside of the subject s right wrist/clavicle. Let the area dry. Then, rough up the skin in that area with an emery board. this improves the conductivity of the electrodes. 7. Remove a disposable ECG electrode from its plastic shield, and apply the electrode to the scrubbed area on the wrist. 8. Repeat Steps 6 and 7 for the inside of the left wrist/clavicle and the inside of the right ankle. 9. Snap the lead wires onto the electrodes, so that: the red (+1) lead is attached to the left wrist or under the left clavicle, the black (-1) lead is connected to the right wrist or under the right clavicle, the green (C or ground) lead is connected to the right leg or on the abdomen. 10. Instruct the subject to sit quietly with their hands in their lap. If the subject moves, the ECG trace will move off the top or bottom of the screen. If the subject moves any muscles in the arms or upper body, electromyograms (EMGs) from the muscles will appear on the ECG recording as noise. HH-2-3

Figure HH-2-L1: The C-ISO-B3G ECG cable with three lead wires attached. Figure HH-2-L2: The EM-220 event marker. Figure HH-2-L3: The ECG cable and event marker connected to an IXTA. HH-2-4

Experiment HH-2: The Electrocardiogram and Heart Sounds Exercise 1: The ECG in a Resting Subject Aim: To measure the ECG in a resting individual. Procedure 1. Click on the Record button, located on the upper right side of the LabScribe Main window. The signal should begin scrolling across the screen. Note: If the user clicks the Record button and there is no communication between the iworx unit and computer, an error window will appear in the center of the Main window. Make sure the iworx unit is turned on and connected to the USB port of the computer. Click OK and select the Find Hardware function from the LabScribe Tools menu. 2. Click on the AutoScale button at the upper margin of the ECG channel. If the signal on the ECG channel is upside down when compared to trace, click on the downward arrow to the left of the channel title and select the Invert function. The trace should now look similar to the one in the figure If a larger signal is required, the electrodes should be moved from the wrists to the skin just below each clavicle. 3. When you have a suitable trace, type <Subject s Name> Resting ECG in the Mark box to the right of the Mark button. Press the Enter key on the keyboard to attach the comment to the data. Record for a minute or two. 4. Click Stop to halt recording. 5. Select Save As in the File menu, type a name for the file. Choose a destination on the computer in which to save the file, like your lab group folder. Designate the file type as *.iwxdata. Click on the Save button to save the data file. Data Analysis 1. Scroll through the recording and find a section of data with four to six good ECG cycles in succession. 2. Use the Display Time icons to adjust the Display Time of the Main window to show at least four complete ECG cycles on the Main window. Four adjacent ECG cycles can also be selected by: Placing the cursors on either side of a group of four complete ECG cycles. Clicking the Zoom between Cursors button on the LabScribe toolbar to expand the segment with the four selected ECG cycles to the width of the Main window. HH-2-5

3. Click on the Analysis window icon in the toolbar (Figure HH-2-L1) or select Analysis from the Windows menu to transfer the data displayed in the Main window to the Analysis window (Figure HH-2-L2). Figure HH-2-L1: The LabScribe toolbar. 4. Look at the Function Table that is above the uppermost channel displayed in the Analysis window. The names of the mathematical functions used in the analysis, V2-V1 and T2-T1, appear in this table. The values for V2-V1 and T2-T1 from each channel are seen in the table across the top margin of each channel. 5. Once the cursors are placed in the correct positions for determining the amplitudes and the beat period on each ECG cycle, the values of these amplitudes and the time interval can be recorded in LabScribe by typing their names and values directly into the Journal, or on a separate data table. 6. The functions in the channel pull-down menus of the Analysis window can also be used to enter the names and values of the parameters from the recording to the Journal. To use these functions: Place the cursors at the locations used to measure the amplitudes and period of the ECG cycle. Transfer the names of the mathematical functions used to determine the amplitudes and time interval to the Journal using the Add Title to Journal function in the ECG Channel pull-down menu. Transfer the values for the amplitudes and beat period to the Journal using the Add Ch. Data to Journal function in the ECG Channel pull-down menu. 7. Use the mouse to click on and drag the cursors to specific points on the ECG recording to measure the following: The R-wave amplitude. To measure the R wave amplitude, place one cursor on the Q wave that precedes the R wave and the second cursor on the peak of the R wave. The value for V2-V1 on the ECG channel is this amplitude. Measure the amplitudes of two additional R waves. The P-wave amplitude. To measure the P wave amplitude, place one cursor on the baseline that precedes the P wave and the second cursor on the peak of the P wave. The value for V2-V1 on the ECG channel is this amplitude. Measure the amplitudes of two additional P waves. The T-wave amplitude. To measure the T wave amplitude, place one cursor on the HH-2-6

baseline that precedes a P wave and the second cursor on the peak of the T wave that is in the same cycle as that P wave. The value for V2-V1 on the ECG channel is this amplitude. Measure the amplitudes of two additional T waves. The beat period, which is the time interval between two adjacent R waves. To measure the beat period, place one cursor on the peak of a R wave and the second cursor on the peak of the adjacent R wave. The value for T2-T1 on the ECG channel is the beat period. Measure the beat period for two additional pairs of R waves. Figure HH-2-L2: ECG recording displayed in the Analysis window. Lines and labels were added to indicate the locations where cursors should be placed to measure the amplitudes of R (Q-R), P (Baseline-P), and T (Baseline-T) waves. 8. Calculate the following values and type your results into the Journal, or on a separate data sheet: Questions The average amplitudes of the P wave, the R wave, and the T wave. The average beat period, in seconds/beat. The heart rate, which is expressed in beats per minute and calculated from the average beat period by using the following equation: Heart Rate (beats/minute) = 60 seconds/minute # seconds/beat 1. Is the amplitude of each wave (P, QRS, T) always the same in different cardiac cycles? 2. Which wave has the largest amplitude? 3. What is the average resting heart rate of the subject? HH-2-7

Exercise 2: ECG Recordings from Other Subjects Aim: To measure heart rate from all students. Procedure 1. Disconnect the lead wires from the wrists and ankle of the first subject. 2. Place new ECG electrodes on another subject. Record the ECG from the second subject, as described in Exercise 1. 3. Repeat this exercise on additional subjects, within the time limits of the lab period. At the beginning of each recording, type the name of the subject on the Marks line and click on the Marks button to identify the recording. Data Analysis Measure the amplitudes of the ECG waves and beat periods of the other subjects using the same techniques used in the analysis section of Exercise 1. Questions 1. Do the P waves of different subjects have the same amplitude? The QRS complexes? The T waves? Why? 2. For each subject, determine the wave with the largest amplitude. Is this result the same for all individuals? 3. Is the heart rate the same for each individual? 4. What is the range of resting heart rates within the class? 5. Are there any obvious correlations between resting heart rate and gender, apparent fitness, or diet of your subjects? To determine apparent fitness, the class may want to compose a list of questions that will allow you to assign a relative fitness factor to each subject. Exercise 3: The ECG and Heart Sounds Aim: To study the phasing of heart sounds to the ECG. Procedure 1. Place the head of the stethoscope on the left side of the subject s chest and listen for the heart sounds. Move the stethoscope head to different positions until heart sounds are heard clearly. Heart sounds can also be heard by placing the stethoscope over the arteries in the neck. 2. Click on the Record button. Hold the stethoscope head on the subject s chest with one hand and the event marker in the other. Press the event marker when you hear the lub, or first heart sound, and release it when you hear the dub, or second heart sound. 3. After recording for twenty seconds, click Stop to halt recording. 4. Select Save in the File menu on the LabScribe window. HH-2-8

Data Analysis 1. Scroll through the recording and find a section of data with four to six exemplary ECG waveforms and consistent responses on the event marker channel, in succession. 2. Use the Display Time icons to adjust the Display Time of the Main window to show at least four complete ECG/heart sound cycles on the Main window. Four adjacent ECG/heart sound cycles can also be selected by: Placing the cursors on either side of a group of four complete ECG/heart sound cycles; and Clicking the Zoom between Cursors button on the LabScribe toolbar to expand the segment with the four selected ECG/heart sound cycles to the width of the Main window. Click on the Analysis window icon in the toolbar (Figure HH-L1) or select Analysis from the Windows menu to transfer the data displayed in the Main window to the Analysis window (Figure HH-2-L3). Figure HH-2-L3: ECG and event marker recordings displayed in the Analysis window. Lines and labels were added to figure to indicate the locations where cursors should be placed to measure the time intervals between the R wave and the lub and the T wave and the dub. 3. Once the cursors are placed in the correct positions for determining the time intervals on each ECG cycle, the values of these intervals can be recorded by typing their names and values directly into the Journal, or on a separate data table. 4. The functions in the channel pull-down menus of the Analysis window can also be used to enter the names and values of the intervals from the recording to the Journal. To use these functions: HH-2-9

Place the cursors at the locations used to measure the time intervals between the ECG waves and the heart sounds. Transfer the name of the mathematical function used to determine the time intervals to the Journal using the Add Title to Journal function in the ECG Channel pull-down menu. Transfer the values for the time intervals to the Journal using the Add Ch. Data to Journal function in the ECG Channel pull-down menu. 5. Use the mouse to click on and drag the cursors to specific points on the ECG recording to measure the following: The R-Lub Interval, which is the time interval between the peak of a R wave and the onset of the event mark. The onset of the event mark indicates the occurrence of the first heart sound or lub. Record the value for T2-T1 of either channel. Measure this time interval for two additional ECG cycles. The T-Dub Interval, which is the time interval between the peak of a T wave and the offset of the event mark. The offset of the event mark indicates the occurrence of the second heart sound or dub. Record the value for T2-T1 of either channel. Measure this time interval for two additional ECG cycles. 6. Calculate the following values and type your results into the Journal The average R-Lub interval. The average T-Dub interval. Questions 1. Why does the lub sound occur around the peak of the R wave? 2. Is the time delay between the R wave and the lub sound always the same? Explain why the time delay is or is not the same. 3. Why does the dub sound occur around the peak of the T wave? 4. Is the time delay between the T wave and the dub sound always the same? Explain why the time delay is or is not the same. HH-2-10