The EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to.
|
|
|
- Marion Weaver
- 9 years ago
- Views:
Transcription
1 Heart Rate Sensor Heart Rate Sensor (Product No PC-3147) Pulse rate Range: 0 to 200 bpm Resolution: 1 bpm Waveform Range: to 2000 mv Resolution: 1 mv Introduction The Smart Q Heart Rate Sensor monitors the light level transmitted through the vascular tissue of the fingertip or the ear lobe and the corresponding variations in light intensities that occurs as the blood volume changes in the tissue. The EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to. Connecting Hold the Heart Rate Sensor housing with the Smart Q label showing on the top. Push one end of the sensor cable (supplied with the EasySense unit) into the socket at the end of the Sensor housing with the locating arrow on the cable facing upwards. Connect the other end of the sensor cable to the Input socket on the EasySense unit (with the locating arrow facing upwards). Insert the jack plug from the finger/ear lobe clip (Pleth) into the jack socket at the end of the Sensor housing. The EasySense unit will detect that the Heart Rate Sensor is connected. Select the range required. To set the range The methods available to alter the selected range of the Sensor will depend on the type of EasySense unit used. EasySense Advanced and Logger Users can set the required range from the unit: - Use the scroll buttons ( ) on the unit to select the System Menu, ENTER. Use the scroll buttons to select Set Sensor range, ENTER. Select the number of the input that the Heart Rate Sensor is attached to e.g. Input 1 ENTER. Use the scroll buttons to view the ranges available i.e. Waveform or Beats / min An asterisk* will indicate the present range selected. Press ENTER to select the desired range. Press STOP to return to the main menu.
2 EasySense Advanced, Logger, Fast, and Real-time Users can set the required range using the Sensor configuration application in the Sensing Science Laboratory program: - Connect the Heart Rate Sensor to the EasySense unit and run the Sensor Configuration program. Select the number of the input that the Sensor is connected to from the list. Click on the Set Range button. The current range will be highlighted. Select the required range and click on OK. Exit the program. The Sensor range setting will be retained until reselected. Measurement procedure Infrared LED The Pleth Light Sensitive Detector 1. Attach the Pleth (finger/ear lobe clip) to either the fingertip or to the ear lobe. Note: Do not apply pressure to the Pleth as this could affect the signal. 2. Wait for a short while for the signal to stabilise. The subject should stay reasonably still muscle movements will influence the signal. The red LED on the Sensor housing will start to flash in time with the heartbeat. If used on the finger the subject may feel a throbbing sensation. Note for EasySense Advanced and Logger users: if the red LED does not start to flash, and the LCD display on the EasySense unit is blank, press any of the buttons on the top panel of the EasySense unit to wake it up. 3. Once a regular heart rate is detected, begin recording data. Backgound The Smart Q Heart Rate Sensor is used to measure the cardiovascular pulse wave that is found throughout the human body. This pulse wave will result in a change in the volume of arterial blood with each pulse beat. This change in blood volume can be detected in peripheral parts of the body such as the fingertip or ear lobe using a technique called Photoplethysmography. The device that detects the signal is called a plethysmograph (or Pleth for short).
3 The Pleth consists of: An infrared LED which illuminates the tissue and A light sensitive detector (LSD), which has been tuned to the same colour frequency as the LED, and detects the amount of light transmitted from the tissue. The Pleth supplied with this sensor is a transmission mode plethysmographic signal (PPG) device, which uses transmitted light to estimate absorption The infrared LED and the light sensitive detector (LSD) are mounted in a springloaded device that can be clipped onto the fingertip or ear lobe. LED Finger Vascular Bed The Pleth LSD The infrared light emitted by the LED is diffusely scattered through the fingertip or ear lobe tissue. A light sensitive detector positioned on the surface of the skin on the opposite side can measure light transmitted through at a range of depths. Infrared light is absorbed well in blood and weakly absorbed in tissue. Any changes in blood volume will be registered since increasing (or decreasing) volume will cause more or less absorption. Assuming the subject does not move, the level of absorption of the tissue and non-pulsating fluids will remain the same. A b s o r p t i o n Absorption due to changes in arterial blood volume Absorption due to arterial blood L e v e l Practical Information The amount of light that can be detected by the Light Sensitive Detector will vary as to the subject or whether the Pleth is attached to a fingertip or the earlobe. When the Heart wave range is selected, the amplitude of the heart wave will demonstrate this effect. When attached to a finger: Absorption due to venous blood Absorption due to bone tissue and skin
4 It is better to position the Pleth so that the Light Sensitive Detector is on the fleshy side of the finger. Fingers should be clean. Nail varnish may cause falsely low readings. Values should not be affected by skin colouring. Some subjects may have poor peripheral circulation (the extent to which the blood vessels in the fingertip are filled with blood), in which case another subject should be selected. If the heart rate does not seem to settle, try warming the hands by rubbing to increase the blood flow. If readings are lower than expected, try repositioning the Pleth to make sure a firm contact is obtained. Attached to an Ear Lobe: Remove any earrings before attaching to the ear lobe. The Pleth can be made more secure by hooking the wire round the back of the ear or by using the clip on the lead to attaching it to the subject s clothing. If the heart rate does not settle or if readings are lower than expected, try repositioning the Pleth to make sure a firm contact is obtained. Each time the Pleth is attached to a fingertip or ear lobe, wait until the signal stabilises before starting to record data - the initial unstable signal will be due to compression from the Pleth being attached. Stay reasonably still while recording data. Movement e.g. raising and lowering a hand, will alter the pressure the finger exerts on the Pleth whilst simultaneously causing a change in venous blood that will affect light transmission through the tissue. It is possible to alter the heart rate by simply decreasing respiratory rate and relaxing. Encourage the subject to breath normally. If the Pleth loses contact with the pulse, the Sensor will attempt to re-establish communication. This may result in the reading momentarily dropping to zero. The heart rate is averaged over every five beats to achieve a smoother reading. This Sensor is not intended for medical diagnosis. Do not be alarmed if results do not correspond to the quoted numbers. These numbers represent typical averages and many healthy hearts have data that falls outside these parameters. It is quite normal for the heart to occasionally miss a beat. It is possible for the dicrotic notch to be recorded as a separate pulse. This Sensor is not waterproof. Clean the Pleth by wiping with a cloth that has been rinsed in disinfectant. The Light Sensitive Detector in the Pleth can be sensitive to high levels of ambient infrared light e.g. strong sunlight.
5 Example of the type of dicrotic notch that may affect Heart Rate data. Heart Rate Blood passes through the heart in two phases that alternate continuously. Diastole (heart expanding) The muscles of the ventricles relax The atrio-ventricular valves open The arterial valves close Blood flows from atria into ventricles Systole (heart contracting) The muscles of the ventricles contract The atrio-ventricular valves close The arterial valves open Blood flows from the ventricles into arteries The blood forced into the aorta during systole moves the blood in the vessels forwards and sets up a pressure wave that travels along the arteries. This pressure wave expands the arterial walls as it travels and is felt as the pulse. The pulse may be felt at points where arteries pass over bones, known as pressure points e.g. in the wrist and neck. Pulse rate is a direct measure of the number of heart cycles in a minute (heart rate). Heart rate can vary with age as shown below: Age Average Heart Rate (beats per minute) Newborn years years Adult In normal healthy individuals the heart rate, and thus the pulse rate, varies with the phases of respiration. Irregular changes in heart rate occur in all people. Heart rate may be increased by exercise, nervous excitement, stress due to mental effort, by adrenaline entering the bloodstream or with increase in temperature caused by fever. The heart rate decreases when asleep and some medical conditions may also cause a drop. Effect of Exercise Physical training can increase the efficiency of the heart and thus the resting heart rate is decreased. The athlete s heart is usually larger than that of an untrained individual. Constant training, with its increased workload against which the heart must contract, results in enlargement of the myocardial fibres with associated biochemical changes. This modifies the performance of the heart, increasing stroke volume (the volume of blood pumped by the heart at each beat), and permitting the athlete to achieve the same cardiac output with a slower heart rate. The resting heart rate in an athlete may be as low as beats per minute: but with an increased stroke volume of ml, compared with 70 80ml in an untrained individual.
6 With increased heart rate it would be expected that stroke volume would decrease because less filling time is available. In fact, during exercise the sympathetic nervous system acts to increase it, by increasing the vigour of myocardial contraction. As a result, the output of the heart per minute tends to increase proportionately with increase in heart rate. Recovery Time Following exercise it takes a while for the heart rate to return to resting level. This is the recovery time and gives an indication of the fitness of the individual. Recovery time may vary from less than five minute in very fit individuals to around 15 minutes. Safe Pulse Rates During experiments the safe heart rate should not be exceeded. The safe level is given as the maximum heart rate for age, minus 20 beats per minute Maximum heart rate = 210 (0.65 x age) Age Maximum Heart Rate Safe Heart Rate It is important that investigations do not become a competition. Consider any possible health problems before selecting the subject. Waveform The heartbeat recorded by the Smart Q Heart Rate sensor is smoothed by the passage of blood through the capillaries and the pressure signal does not resemble the pulse seen in an electrocardiogram* (which is used to record the hearts electrical activity). However, the periodicity of the signal is unchanged and the Heart Rate sensor can be effectively used to detect changes in heart rate. The upstroke, called the anacrotic limb, is abrupt and is due to contraction of the ventricle (systole). The downstroke is more gradual and corresponds to the elastic recoil of the arterial walls. The downstroke regularly shows a fluctuation known as the dicrotic notch. This is due to vibrations set up when the aortic valve snaps shut it has no major significance as an indicator of health. Dicrotic Notch Anacrotic limb
7 For a healthy person at rest, the heart beats on average at about 60 beats per minute or one a second i.e. around 1Hz. This frequency is not constant (even in a healthy individual at rest). It only takes approximately one second to record a complete wave, so it is usually best to select a short recording time. * An Electrocardiogram (ECG) is a measure of the heart rhythms and electrical impulses. The contraction of the heart occurs due to electrical impulses that are generated within the heart The P-Wave represents the impulse across the atria to the A/V Node The QRS represents the impulse as it travels across the ventricles The T wave represents the repolarization of the ventricles. P Q R T S An example of an Electrocardiogram Fastest Recording Time When used with EasySense Advanced and Fast, users can utilise Fast mode. The fastest speed that the Heart Rate sensor can be used with to capture data will depend on the EasySense unit s operating system. Version EasySense users can log at 40Hz* (25ms). Version 1.4 and upward can log at 50Hz (20ms). If an intersample time of less than 20 milliseconds (or 25 milliseconds for EasySense operating system users) is selected, then the values obtained will default to zero. To check the version number of your EasySense unit, Select the Sensor Configuration application from the Sensing Science Laboratory program. Click on the EasySense Information button for the version number to be displayed. EasySense Advanced and Logger users can also check by carrying out a HARD RESET (by holding down the STOP, METER and ENTER buttons at the same time). The LCD will momentarily display the word EasySense and the version number of its operating system. * To be consistent with the logging time of 40Hz, the Graph application of the Sensing Science Laboratory software has had an intersample time of 25 milliseconds added to the Fast menu. If the
8 version of your Sensing Science Laboratory software does not offer this speed as an option, please contact Arbor Scientific for upgrade information. Investigations Monitoring fitness - after exercise pulse is timed until it gets back to the normal standing heart rate (this can be achieved by remaining in a sitting position and moving the legs). Monitoring resting Changes with mild stimulants (cups of coffee or cola might show less effect on people who are accustomed to large amounts of caffeine). Variation in blood flow i.e. people who suffer with cold fingers will show a very low blood flow in their veins try warming their hands Investigating pulse rate with different body positions (sitting, crouching, standing, laying down). The effect of music on pulse rate. The effect of the strictest teacher entering the room! Warranty All EasySense sensors are warranted to be free from defects in materials and workmanship for a period of 12 months from the date of purchase provided they have been used in accordance with any instructions, under normal laboratory conditions. This warranty does not apply if the sensor has been damaged by accident or misuse.
Note: The left and right sides of the heart must pump exactly the same volume of blood when averaged over a period of time
page 1 HEART AS A PUMP A. Functional Anatomy of the Heart 1. Two pumps, arranged in series a. right heart: receives blood from the systemic circulation (via the great veins and vena cava) and pumps blood
Electrocardiography I Laboratory
Introduction The body relies on the heart to circulate blood throughout the body. The heart is responsible for pumping oxygenated blood from the lungs out to the body through the arteries and also circulating
Project 4.2.1: Heart Rate
Project 4.2.1: Heart Rate Introduction Even before you were born, one of the first things your doctor did when you went for an office visit was listen to your heart. Your heart rate, the number of times
NEULOG HEART RATE AND PULSE LOGGER SENSOR GUIDE
NeuLog heart rate and pulse logger sensor NUL-208 The NeuLog pulse sensor can be used for any science experiment which requires a human heart rate or pulse measurement such as in the fields of Biology,
Activity 4.2.3: EKG. Introduction. Equipment. Procedure
Activity 4.2.3: EKG The following is used with permission of Vernier Software and Technology. This activity is based on the experiment Analyzing the Heart with EKG from the book Human Physiology with Vernier,
Exchange solutes and water with cells of the body
Chapter 8 Heart and Blood Vessels Three Types of Blood Vessels Transport Blood Arteries Carry blood away from the heart Transport blood under high pressure Capillaries Exchange solutes and water with cells
Electrocardiogram and Heart Sounds
Electrocardiogram and Heart Sounds An introduction to the recording and analysis of electrocardiograms, and the sounds of the heart. Written by Staff of ADInstruments Introduction The beating of the heart
Evaluation copy. Analyzing the Heart with EKG. Computer
Analyzing the Heart with EKG Computer An electrocardiogram (ECG or EKG) is a graphical recording of the electrical events occurring within the heart. In a healthy heart there is a natural pacemaker in
Functions of Blood System. Blood Cells
Functions of Blood System Transport: to and from tissue cells Nutrients to cells: amino acids, glucose, vitamins, minerals, lipids (as lipoproteins). Oxygen: by red blood corpuscles (oxyhaemoglobin - 4
Monitoring EKG. Evaluation copy
Monitoring EKG Computer 28 An electrocardiogram, or EKG, is a graphical recording of the electrical events occurring within the heart. A typical EKG tracing consists of five identifiable deflections. Each
Exercise, the Electrocardiogram, and Peripheral Circulation
iworx Physiology Lab Experiment Experiment HH-3 Exercise, the Electrocardiogram, and Peripheral Circulation Note: The lab presented here is intended for evaluation purposes only. iworx users should refer
Factors Affecting Blood Pressure. Vessel Elasticity Blood Volume Cardiac Output
Factors that Affect Pressure Graphics are used with permission of: Pearson Education Inc., publishing as Benjamin Cummings (http://www.aw-bc.com) Page 1. Introduction pressure is affected by several factors:
Chapter 20: The Cardiovascular System: The Heart
Chapter 20: The Cardiovascular System: The Heart Chapter Objectives ANATOMY OF THE HEART 1. Describe the location and orientation of the heart within the thorax and mediastinal cavity. 2. Describe the
HEART HEALTH WEEK 3 SUPPLEMENT. A Beginner s Guide to Cardiovascular Disease HEART FAILURE. Relatively mild, symptoms with intense exercise
WEEK 3 SUPPLEMENT HEART HEALTH A Beginner s Guide to Cardiovascular Disease HEART FAILURE Heart failure can be defined as the failing (insufficiency) of the heart as a mechanical pump due to either acute
Cardiovascular Physiology
Cardiovascular Physiology Heart Physiology for the heart to work properly contraction and relaxation of chambers must be coordinated cardiac muscle tissue differs from smooth and skeletal muscle tissues
Normal & Abnormal Intracardiac. Lancashire & South Cumbria Cardiac Network
Normal & Abnormal Intracardiac Pressures Lancashire & South Cumbria Cardiac Network Principle Pressures recorded from catheter tip Electrical transducer - wheatstone bridge mechanical to electrical waveform
Vtial sign #1: PULSE. Vital Signs: Assessment and Interpretation. Factors that influence pulse rate: Importance of Vital Signs
Vital Signs: Assessment and Interpretation Elma I. LeDoux, MD, FACP, FACC Associate Professor of Medicine Vtial sign #1: PULSE Reflects heart rate (resting 60-90/min) Should be strong and regular Use 2
Efficient Heart Rate Monitoring
Efficient Heart Rate Monitoring By Sanjeev Kumar, Applications Engineer, Cypress Semiconductor Corp. Heart rate is one of the most frequently measured parameters of the human body and plays an important
Circulatory System Review
Circulatory System Review 1. Draw a table to describe the similarities and differences between arteries and veins? Anatomy Direction of blood flow: Oxygen concentration: Arteries Thick, elastic smooth
Normal Intracardiac Pressures. Lancashire & South Cumbria Cardiac Network
Normal Intracardiac Pressures Lancashire & South Cumbria Cardiac Network Principle Pressures recorded from catheter tip Electrical transducer - wheatstone bridge mechanical to electrical waveform display
The Body s Transport System
Circulation Name Date Class The Body s Transport System This section describes how the heart, blood vessels, and blood work together to carry materials throughout the body. Use Target Reading Skills As
Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions
Ultrasound Technologies PD1v vascular pocket doppler Operating Instructions Before using your Pocket Doppler for the first time, please read these operating instructions carefully. 1 INTRODUCTION The UltraTec
Vascular System The heart can be thought of 2 separate pumps from the right ventricle, blood is pumped at a low pressure to the lungs and then back
Vascular System The heart can be thought of 2 separate pumps from the right ventricle, blood is pumped at a low pressure to the lungs and then back to the left atria from the left ventricle, blood is pumped
Section Two: Arterial Pressure Monitoring
Section Two: Arterial Pressure Monitoring Indications An arterial line is indicated for blood pressure monitoring for the patient with any medical or surgical condition that compromises cardiac output,
Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E
Laerdal Patient Monitor Help Page 1 Using the Laerdal Patient Monitor The Laerdal Patient Monitor software is used to simulate a typical Patient Monitor found in hospitals and ambulances. It is made available
Investigating the Human Body On-site student activities: Years 7-8 Investigating the Human Body On-site student activities Years 7 8
Investigating the Human Body On-site student activities Years 7 8 Student activity (and record) sheets have been developed with alternative themes for students to use as guides and focus material during
Heart Rate and Physical Fitness
Heart Rate and Physical Fitness The circulatory system is responsible for the internal transport of many vital substances in humans, including oxygen, carbon dioxide, and nutrients. The components of the
The heart then repolarises (or refills) in time for the next stimulus and contraction.
Atrial Fibrillation BRIEFLY, HOW DOES THE HEART PUMP? The heart has four chambers. The upper chambers are called atria. One chamber is called an atrium, and the lower chambers are called ventricles. In
Heart and Vascular System Practice Questions
Heart and Vascular System Practice Questions Student: 1. The pulmonary veins are unusual as veins because they are transporting. A. oxygenated blood B. de-oxygenated blood C. high fat blood D. nutrient-rich
INTRODUCTORY GUIDE TO IDENTIFYING ECG IRREGULARITIES
INTRODUCTORY GUIDE TO IDENTIFYING ECG IRREGULARITIES NOTICE: This is an introductory guide for a user to understand basic ECG tracings and parameters. The guide will allow user to identify some of the
Section Four: Pulmonary Artery Waveform Interpretation
Section Four: Pulmonary Artery Waveform Interpretation All hemodynamic pressures and waveforms are generated by pressure changes in the heart caused by myocardial contraction (systole) and relaxation/filling
Evaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS
Blood Pressure Project 9 Blood pressure is a measure of the fluid pressure within the circulatory system. This pressure is required to ensure the delivery of oxygen and nutrients to, and the removal of
Motion sensor. DS 041 No 5 DATA HARVEST. (Product No. 3270) Ranges Walk 0.15 3 m Resolution 0.001 m (1 mm)
Smart (Product No. 3270) Ranges Walk 0.15 3 m Resolution 0.001 m (1 mm) Distance 0.15 1 m Resolution: 0.001 m (1 mm) Distance 0.15 2 m Resolution: 0.001 m (1 mm) Distance 0.15 4 m Resolution: 0.001 m (1
Patient Instruction Manual
Patient Instruction Manual Preventice Services, LLC and Preventice Technologies, Inc., are independent, wholly owned subsidiaries of Preventice Solutions, Inc. Welcome to BodyGuardian Verité Your physician
MEASURING VITAL SIGNS TRAINING CHECKLIST
Measuring Vital Signs A guide to help Direct Support Professionals learn how to measure, and report vital sign measurements. Outcomes: Know how to take each individual s vital signs. Demonstrate the correct
Anatomi & Fysiologi 060301. The cardiovascular system (chapter 20) The circulation system transports; What the heart can do;
The cardiovascular system consists of; The cardiovascular system (chapter 20) Principles of Anatomy & Physiology 2009 Blood 2 separate pumps (heart) Many blood vessels with varying diameter and elasticity
HEART MONITOR TREADMILL 12 LEAD EKG
2 HEART MONITOR TREADMILL 12 LEAD EKG Portable ambulatory monitoring system Continuously records electrical activity of the heart for 24 hours or more Also known as ambulatory electrocardiographic monitor
INVESTIGATING HEART RATE AND BLOOD PRESSURE
Hughes Undergraduate Biological Science Education Initiative HHMI INVESTIGATING HEART RATE AND BLOOD PRESSURE Learn how to measure heart rate and blood pressure. Learn the normal values for heart rate
Automatic Wrist Blood Pressure Monitor with
Instruction Manual Automatic Wrist Blood Pressure Monitor with Model HEM-609 ENGLISH ESPAÑOL CONTENTS Before Using the Monitor Introduction...................................... 3 Important Safety Notes.............................
The science of medicine. The compassion to heal.
A PATIENT S GUIDE TO ELECTROPHYSIOLOGY STUDIES OF THE HEART The science of medicine. The compassion to heal. This teaching booklet is designed to introduce you to electrophysiology studies of the heart.
CHAPTER 1: THE LUNGS AND RESPIRATORY SYSTEM
CHAPTER 1: THE LUNGS AND RESPIRATORY SYSTEM INTRODUCTION Lung cancer affects a life-sustaining system of the body, the respiratory system. The respiratory system is responsible for one of the essential
Human ECG Laboratory Experiment By
Human ECG Laboratory Experiment By Brittany Baierlein, Alison L., Thurow, Rachel Holsinger and Robin L. Cooper Department of Biology, University of KY, Lexington, KY 40506-0225, USA. (Some text taken directly
Provided by the American Venous Forum: veinforum.org
CHAPTER 1 NORMAL VENOUS CIRCULATION Original author: Frank Padberg Abstracted by Teresa L.Carman Introduction The circulatory system is responsible for circulating (moving) blood throughout the body. The
Tachyarrhythmias (fast heart rhythms)
Patient information factsheet Tachyarrhythmias (fast heart rhythms) The normal electrical system of the heart The heart has its own electrical conduction system. The conduction system sends signals throughout
Our Human Body On-site student activities Years 5 6
Our Human Body On-site student activities Years 5 6 Our Human Body On-site student activities: Years 5-6 Student activity (and record) sheets have been developed with alternative themes for students to
Heartbeat Monitoring Alert via SMS
Heartbeat Monitoring Alert via SMS Warsuzarina Mat Jubadi Dept. of Electronics Engineering University Tun Hussein Onn Malaysia Batu Pahat, Johor, Malaysia Email: [email protected] Siti Faridatul Aisyah
Biology 347 General Physiology Lab Advanced Cardiac Functions ECG Leads and Einthoven s Triangle
Biology 347 General Physiology Lab Advanced Cardiac Functions ECG Leads and Einthoven s Triangle Objectives Students will record a six-lead ECG from a resting subject and determine the QRS axis of the
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
How to measure blood pressure using digital monitors
How to measure blood pressure using digital monitors What is high blood pressure? Blood pressure is the pressure exerted by circulating blood upon the walls of blood vessels. Systolic pressure is the blood
Page 1. Introduction The blood vessels of the body form a closed delivery system that begins and ends at the heart.
Anatomy Review: Blood Vessel Structure & Function Graphics are used with permission of: Pearson Education Inc., publishing as Benjamin Cummings (http://www.aw-bc.com) Page 1. Introduction The blood vessels
#AS148 - Automated ECG Analysis
BIOPAC Systems, Inc. 42 Aero Camino Goleta, Ca 93117 Ph (805)685-0066 Fax (805)685-0067 www.biopac.com [email protected] #AS148 - Automated ECG Analysis An electrocardiogram (ECG) is a graphical recording
Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003
Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003 Introduction Direct measurement of arterial blood pressure is obtained via a peripheral
Electrodes placed on the body s surface can detect electrical activity, APPLIED ANATOMY AND PHYSIOLOGY. Circulatory system
4 READING AND INTERPRETING THE ELECTROCARDIOGRAM Electrodes placed on the body s surface can detect electrical activity, which occurs in the heart. The recording of these electrical events comprises an
Operating Manual FINGERSIM SET 3-349-631-03 1/5.11. for SECULIFE NIBP in Combination with SECULIFE OX1
Operating Manual FINGERSIM SET for SECULIFE NIBP in Combination with SECULIFE OX1 3-349-631-03 1/5.11 CONTENTS 1 GENERAL WARNINGS AND CAUTIONS... 4 2 PURPOSE... 5 3 DESCRIPTION... 6 4 THEORY OF OPERATION...
CFMRI Physiological Monitoring System. Operator s Manual
CFMRI Physiological Monitoring System Operator s Manual This manual provides a quick guidance to using the physiological monitoring system during an MRI session. It is not intended as a substitute for
Waveforms and the Speed of Sound
Laboratory 3 Seth M. Foreman February 24, 2015 Waveforms and the Speed of Sound 1 Objectives The objectives of this excercise are: to measure the speed of sound in air to record and analyze waveforms of
Practical class 3 THE HEART
Practical class 3 THE HEART OBJECTIVES By the time you have completed this assignment and any necessary further reading or study you should be able to:- 1. Describe the fibrous pericardium and serous pericardium,
To provide the body (cells) with oxygen, and remove CO 2. To provide the body (cells) with nutrients and remove wastes.
Circulatory system. Basic function: To provide the body (cells) with oxygen, and remove CO 2. To provide the body (cells) with nutrients and remove wastes. Not all organisms have a circulatory system -
Circulation Stations
Circulation Stations This worksheet corresponds with stations around the classrooms. Work in groups of 3 and do the stations in any order. Name: Station 1: Blood smear under a microscope Materials: - Microscope
Circulatory System and Blood
Circulatory System and Blood 1. Identify the arteries in the diagram and give one function for each. Y: Common carotid artery: sends oxygenated blood to the brain, provide nutrients. X: Subclavian artery:
VITALMONITOR SOFTWARE FOR PATIENT MONITORING
VITALMONITOR SOFTWARE FOR PATIENT MONITORING A USERS GUIDE Version 1.102 March 2009-1 - USING THE VITALMONITOR SOFTWARE Section 2: Using the VitalMonitor Software... 4 The VitalMonitor and VitalStore programs...
DAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of
Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of the blood 7 Procedure to test glucose 7 Procedure to
What Can I Do about Atrial Fibrillation (AF)?
Additional Device Information 9529 Reveal XT Insertable Cardiac Monitor The Reveal XT Insertable Cardiac Monitor is an implantable patientactivated and automatically activated monitoring system that records
Atrioventricular (AV) node ablation
Patient information factsheet Atrioventricular (AV) node ablation The normal electrical system of the heart The heart has its own electrical conduction system. The conduction system sends signals throughout
Wireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
Anatomy and Physiology: Understanding the Importance of CPR
Anatomy and Physiology: Understanding the Importance of CPR Overview This document gives you more information about the body s structure (anatomy) and function (physiology). This information will help
Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
Lab 3: Introduction to Data Acquisition Cards
Lab 3: Introduction to Data Acquisition Cards INTRODUCTION: In this lab, you will be building a VI to display the input measured on a channel. However, within your own VI you will use LabVIEW supplied
ReSound Unite TV FREQUENTLY ASKED QUESTIONS. Setup & Configuration. Use & Operation. Troubleshooting
Tip for use of FAQ: Click on questions to go to answer. Setup & Configuration How do I pair the hearing aids to the Unite TV?... 2 What is the latency of the streamed signal?... 2 Does the Unite TV use
Pressure Sensor Based Estimation of Pulse Transit Time
International Journal of Information & Computation Technology. ISSN 0974-2239 Volume 4, Number 13 (2014), pp. 1321-1328 International Research Publications House http://www. irphouse.com Pressure Sensor
Chapter 16: Circulation
Section 1 (The Body s Transport System) Chapter 16: Circulation 7 th Grade Cardiovascular system (the circulatory system) includes the heart, blood vessels, and blood carries needed substances to the cells
1 The diagram shows blood as seen under a microscope. Which identifies parts P, Q, R and S of the blood?
1 1 The diagram shows blood as seen under a microscope. Which identifies parts P, Q, R and S of the blood? 2 The plan shows the blood system of a mammal. What does the part labelled X represent? A heart
Introduction to Electrocardiography. The Genesis and Conduction of Cardiac Rhythm
Introduction to Electrocardiography Munther K. Homoud, M.D. Tufts-New England Medical Center Spring 2008 The Genesis and Conduction of Cardiac Rhythm Automaticity is the cardiac cell s ability to spontaneously
Catheter Ablation. A Guided Approach for Treating Atrial Arrhythmias
Catheter Ablation A Guided Approach for Treating Atrial Arrhythmias A P A T I E N T H A N D B O O K This brochure will provide an overview of atrial arrhythmias (heart rhythm problems affecting the upper
Blood Pressure. Blood Pressure (mm Hg) pressure exerted by blood against arterial walls. Blood Pressure. Blood Pressure
Blood Pressure Blood Pressure (mm Hg) pressure exerted by blood against arterial walls Systolic pressure exerted on arteries during systole Diastolic pressure in arteries during diastole 120/80 Borderline
What to Know About. Atrial Fibrillation
Atrial Fibrillation What to Know About Atrial Fibrillation Understanding Afib Atrial fibrillation, or Afib, is a condition in which the heart beats irregularly speeding up or slowing down, or beating too
Equine Cardiovascular Disease
Equine Cardiovascular Disease 3 rd most common cause of poor performance in athletic horses (after musculoskeletal and respiratory) Cardiac abnormalities are rare Clinical Signs: Poor performance/exercise
Lecture Outline. Cardiovascular Physiology. Cardiovascular System Function. Functional Anatomy of the Heart
Lecture Outline Cardiovascular Physiology Cardiac Output Controls & Blood Pressure Cardiovascular System Function Functional components of the cardiovascular system: Heart Blood Vessels Blood General functions
Low Blood Pressure. This reference summary explains low blood pressure and how it can be prevented and controlled.
Low Blood Pressure Introduction Low blood pressure, or hypotension, is when your blood pressure reading is 90/60 or lower. Some people have low blood pressure all of the time. In other people, blood pressure
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. OMEGALOG Help Page 2 Connecting Your Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data Page 11 Downloading
Transcutaneous Electrical Nerve Stimulation Device. Operation Manual Read Before Using
Transcutaneous Electrical Nerve Stimulation Device Operation Manual Read Before Using TABLE OF CONTENTS INTRODUCTION TO TENS INDICATIONS AND CONTRAINDICATIONS WARNINGS PRECAUTIONS/ADVERSE REACTIONS ABOUT
Blood Pressure Regulation
Blood Pressure Regulation Graphics are used with permission of: Pearson Education Inc., publishing as Benjamin Cummings (http://www.aw-bc.com) Page 1. Introduction There are two basic mechanisms for regulating
Information for patients What is an EMG/Nerve Conduction Study?
Information for patients What is an EMG/Nerve Conduction Study? Department of Neurophysiology We must obtain your consent for any procedure beforehand. Staff will explain all the risks, benefits and alternatives
Back-UPS Pro 1300/1500 Installation and Operation
Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a
THE HEART Dr. Ali Ebneshahidi
THE HEART Dr. Ali Ebneshahidi Functions is of the heart & blood vessels 1. The heart is an essential pumping organ in the cardiovascular system where the right heart pumps deoxygenated blood (returned
Atrial Fibrillation (AF) Explained
James Paget University Hospitals NHS Foundation Trust Atrial Fibrillation (AF) Explained Patient Information Contents What are the symptoms of atrial fibrillation (AF)? 3 Normal heartbeat 4 How common
Diagram 2(i): Structure of the Neuron
Diagram 2(i): Structure of the Neuron Generally speaking, we can divide the nervous system into different parts, according to location and function. So far we have mentioned the central nervous system
body fat scale + Instruction Manual complete body analysis scale HEALTH
HEALTH body fat scale + complete body analysis scale Instruction Manual Content Safety instructions... 4 About this device... 4 General... 4 Handling batteries properly... 5 Never carry out repairs yourself...
INSTRUCTION MANUAL. Ultra Premium Blood Pressure Monitor featuring ComFit TM Cuff. Model HEM-775
INSTRUCTION MANUAL Ultra Premium Blood Pressure Monitor featuring ComFit TM Cuff Model HEM-775 ENGLISH ESPAÑOL TABLE OF CONTENTS Before Using the Monitor Introduction..................................................4
AD-01 Slave Auto Dialer. Owner s Manual
AD-01 Slave Auto Dialer Owner s Manual AD-01 Slave Manual.indd 1 10/15/2009 10:20:44 AM 2 AD-01 Slave Manual.indd 2 10/15/2009 10:20:44 AM Features: Programmable entry/exit delay time; select up to 9 (32
Blood Vessels and Circulation
13 Blood Vessels and Circulation FOCUS: Blood flows from the heart through the arterial blood vessels to capillaries, and from capillaries back to the heart through veins. The pulmonary circulation transports
MEASURING AND RECORDING BLOOD PRESSURE
MEASURING AND RECORDING BLOOD PRESSURE INTRODUCTION The blood pressure, along with the body temperature, pulse, and respirations, is one of the vital signs. These measurements are used to quickly, easily,
Distance Learning Program Anatomy of the Human Heart/Pig Heart Dissection Middle School/ High School
Distance Learning Program Anatomy of the Human Heart/Pig Heart Dissection Middle School/ High School This guide is for middle and high school students participating in AIMS Anatomy of the Human Heart and
Acute heart failure may be de novo or it may be a decompensation of chronic heart failure.
Management of Acute Left Ventricular Failure Acute left ventricular failure presents as pulmonary oedema due to increased pressure in the pulmonary capillaries. It is important to realise though that left
Microwave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
Fingertip Pulse Wave (PPG signal) Analysis and Heart Rate Detection Swarup Sarkar 1, Akash Kumar Bhoi 2, Gyanesh Savita 3 1,2,3
Fingertip Pulse Wave (PPG signal) Analysis and Heart Rate Detection Swarup Sarkar 1, Akash Kumar Bhoi 2, Gyanesh Savita 3 1,2,3 Department of AE&I Engg, Sikkim Manipal Institute of Technology (SMIT), Majitar
User Manual I1010Q16DCZ
User Manual I1010Q16DCZ Explanation, Note and Warning *Explanation: important information, which can help you better use your tablet PC. *Note: indicates that not observing the content may result in hardware
Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation
1 Contents Contents Contents 2 Overview 3 Charging your headset 4 Wearing the headset 4 Powering on the headset 4 Connecting your headset for dictation 5 The adapter 5 Adjusting your computer's audio settings