For detailed information of each model, please refer to the product specification sheets.

Similar documents
Online Infrared Flue Gas Analyzer Gasboard 3000

Application Requirement

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Electronic Flow Switches

Buckeye Detection Systems Fixed Detection Systems Application Survey

In-Line Electronic Flow Switches

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

Mass Flow Meters & Controllers

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Sanitary Type Electronic Flow Switches

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

Temperature & Humidity SMS Alert Controller

Regards from the Team at Rheology Solutions.

Micro Motion 3098 Gas Specific Gravity Meter

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Advanced Solutions for Gas Monitoring

Analytical Instruments Smart Analyzer 90 Type SMA

sierra monitor corporation Fire and Gas Detection Systems

Metering for today s systems

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

ABSTRACT INTRODUCTION

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Triple Waveband Infra-Red Flame Detection

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

COMBIMASS. Technical Data COMBIMASS eco-bio +

DUST EMISSION MONITORING SYSTEM

Microcor Wireless Transmitter (MWT)

The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers

DigitalFlow GF868 Panametrics Ultrasonic Flare Gas Mass Flowmeter. GE Sensing. Features. Applications

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

Fiber Optic Distributed Temperature Sensor (B-DTS)

In-Line Electronic Flow Switches

HySTAT HYDROGEN GENERATORS

Boiler Control Solution. Boiler Control Solution. Instruments and Solution for Automatic Boiler Control LF3BUSS02-00EN.

PIEZOMETER AIRFLOW MEASURING RING

Ultima X Series Gas Monitors

For Multi-Parameter Meters see mvx

EXPLORER 4 MULTIPOINT

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Thermal Mass Flow Meters

kajaanipolarox Measure and Control Active Bleaching Chemicals kajaani

Sentry-MS. Cost Effective Perimeter & LDAR Monitoring. ...Precise, Species Specific. Open Path Multi-gas UVDOAS Analyzer. Ammonia.

Condumax II Hydrocarbon Dew-Point Analyzer

Process Instrumentation

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

O C M III. Open Channel Flow Monitor

PRODUCT PROFILE FEATURES

Engineering Specifications XNX Universal Transmitter

WEATHER STATION FOR SOLAR FARM MONITORING

Mass Flow Meter Product Guide

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

Natural gas chromatograph LNG gas quality testing

SULFUR RECOVERY UNIT. Thermal Oxidizer

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

MATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence

SMS GSM Alarm Messenger

TRL-onlineTOC Monitor is designed for monitoring carbon content in

DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

ClampOn DSP Pig Detector

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

S300 Series Dust Monitors

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Dialight Control and Monitoring System for Vigilant LED Based Obstruction System for High Intensity Installations. FAA Type B FAA Type C FAA Type F

DissolvedOxygenMonitor

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

How To Choose A Total Organic Carbon Analyzer

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

DCM. Product Brochure. Diagnostic Communication Master

The Ambient Air Monitoring System

HDO700 P FIBRE OPTIC TRANSMITTER

Table of Contents. TransformerIQ FAQs 1

How To Use A Ds340 (Dsp)

Dew-Point Measurement Solutions

MSA Fixed Gas & Flame Detection for the Water & Wastewater Industries

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

MLC TM Maximum Productivity and Versatility for Control without Compromise!

API Marine. BMS Presentation. Ballast Measurement Systems

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

Flame detection across the spectrum. Range Brochure

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Chassis, Power Supply, and Element Management

Electronic, Digital and Mechanical Vibration Switches

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Thyristor-controlled power supplies and battery chargers

Transcription:

AMETEK Western Research UV VIS photometric analyzers are the most recognized in the world. We are one of the largest suppliers of UV analyzers worldwide, and we are the undisputed world leader for sulfur recovery analyzers. We also produce a number of other analyzers used to monitor a tremendous variety of chemical concentrations and properties. Sulfur Recovery Plant Analyzers Sulfur has been known since 2000 B.C., when it was used for bleaching linen. Element Sulfur exists in coal and refinery crude oil. Another big source of Sulfur is the H 2 S associated with the natural gas. To improve the product quality and decrease the SO 2 emission after the fuel combustion, Sulfur needs to be separated, always in the form of H 2 S. Then, H 2 S is processed to recover elemental Sulfur by Claus and modified Claus process. With over 18 analyzers dedicated to the Sulfur recovery process, AMETEK can fulfill your analysis needs in gas sweetening, acid gas analysis, tail gas analysis, pit gas monitoring, tail gas treating processes and emissions monitoring. Emission Monitors Perform dry- or wet-basis analysis using one of AMETEK's complete line of emission monitors. Monitor just SO 2 or up to five gases simultaneously including SO 2, NO, NO 2, NOx, H 2 S or NH 3. Mass flow and optional oxygen measurements are also available. Whether you need a 19" rack-mount analyzer designed for stand-alone use or for integration into a CEM system or a complete hot/wet extractive stack monitoring system, AMETEK can provide a solution. Natural Gas Processing AMETEK manufactures a number of analyzers for use in natural gas quality monitoring and control. Whether you monitor H 2 S in sour gas, H 2 S/COS/MeSH in sweet gas, or hydrocarbon dew point, we have an analyzer to suit your needs. For detailed information of each model, please refer to the product specification sheets. 04

Model 880 881 Analyzer Tail gas analyzer H 2 S in sulfur pit analyzer Single source multi-wavelength Non-dispersive ultraviolet Single source multi-wavelength Non-dispersive ultraviolet Components H 2 S, SO 2, Sv H 2 S, SO 2 Range H 2 S: 0-2%, SO 2 : 0-1% Excess H 2 S: -1%-1%; (H 2 S: 0-4%, SO 2 : 0-2% option) H 2 S: 0-5%, SO 2 : 0-1% Other ranges on request Response time T90<15 Seconds T90<15 Seconds Precision ±2% Full Scale ±2% Full Scale Repeatability ±1% Full Scale ±1% Full Scale Calibration Optical filter Optical filter Linearity ±0.6% of Span ±0.6% of Span Noise ±0.5% Full Scale ±0.5% Full Scale Flow rate 2 L/Minute 2 L/Minute Sampling No sample line, with aspirator No sample line, with aspirator Temperature and pressure With With Analog output (3~4) 4-20mA (3~4) 4-20mA Communication RS-232/RS-485 RS-232/RS-485 Alarm Digital Digital Power 115/230 VAC 50/60 Hz 115/230 VAC 50/60 Hz Power consumption 720W 690W Instrument air 490-700 kpa 490-700 kpa Others Steam: 515~690 kpa (steam jacket for ball valve); Steam: 515~690 kpa (steam jacket for ball valve) 210~345 kpa (blow back) Explosion proof area Class I, Division 2, Group A, B, C, D; Zone 1, EExp II C T3 Class I, Division 2, Group A, B, C, D; Zone 1, EExp II C T3 Enclosure NEMA 4 NEMA 4 Operation temperature -20 C~50 C -20 C~50 C Dimension H W D (mm) 1037 950 305 1161 914 305 Weight 115 kg 115 kg Installation Mounts directly on the process pipe Mounts directly on sulfur pit lid Main applications Tail gas for Sulfur Recovery Unit Sulfur pit No sample line is needed; Long lamp life (5 years) No sample line is needed; Long lamp life (5 years) 05

Model 900 909 910 Analyzer Air demand analyzer (Tail Gas) Hot/wet single gas mass flow CEM Hot/wet multi-gas CEM Dual sources, multi-wavelength, Dual beam, high resolution, nondispersive UV Dual beam, Multi-wavelength, Components H 2 S, SO 2, CS 2, COS, Sv SO 2, NO, NO 2, H 2 S, NH 3, CL 2, O 2 (Optional ZrO 2 detector) Range H 2 S: 0-5000ppm-100%; SO 2 : 0-2500ppm-100%; CS 2 : 0-5000ppm-100%; COS: 0-5000ppm-100%; Sv: 0-50ppm-500ppm NH 3 : 0-125ppmn-100%; Cl 2 : 0-500ppm-100% SO 2, NO, NO 2, H 2 S, NH 3, CL 2, O 2 (Optional ZrO 2 detector) NOx: 0-300ppm-100%; NH 3 : 0-125ppm-100% Response time T90<30 Seconds T90<30 Seconds T90<30 Seconds Precision H 2 S, SO 2 : ±1% Full Scale ±1% Full Scale; O 2 : ±0.1% ±1% Full Scale; O 2 : ±0.1% Repeatability H 2 S, SO 2 : <0.5% Full Scale <±0.5% Full Scale <±0.5% Full Scale Calibration Manual or automatic Manual or automatic Manual or automatic Linearity H 2 S, SO 2 : 1% Full Scale <±1% Reading SO 2 : ±1% Reading; NOx, H 2 S, NH 3 : <±1.5% Reading Noise H 2 S, SO 2 : 0.2% Full Scale <0.2% Full Scale <0.2% Full Scale Flow rate 3-5 L/Minute 3-5 L/Minute 3-5 L/Minute Sampling Aspirator Aspirator Aspirator Temperature and pressure With With With Analog output Four 4-20mA (self or loop powered) Four 4-20mA (self or loop powered) Four 4-20mA (self or loop powered) Communication One RS-422 Serial port (supports Modicon Modbus RTU), One RS-232 Serial port (typically reserved for configurator software). Optional ports are RS-485 (supports Modicon Modbus RTU) or RJ-45 Ethernet port (supports Modicon Modbus TCP/IP) Alarm Power 120/240 VAC ±10%, 47~63 Hz 120/240 VAC ±10%, 47~63 Hz 120/240 VAC ±10%, 47~63 Hz Power consumption 600 W (for analyzer) 600 W 600 W Instrument air >413.6 kpa,120 L/Minute >413.6 kpa,120 L/Minute >413.6 kpa,120 L/Minute Explosion proof area Enclosure NEMA 4* NEMA 4* NEMA 4* Operation temperature 5~50 C 5~50 C 5~50 C Dimension H W D (mm) 1554 1118 306 1554 1118 306 1554 1118 306 Weight 160 kg About 160 kg About 160 kg Installation Back panel Back panel Back panel Main applications Tail gas pipeline for Sulfur Recovery Unit * To be installed in analyzer house CEM for Sulfur plant Wet scrubber (high water dew point) Hot/wet measurement; ; Optional flow meter CEM for Sulfur plant Wet scrubber (high water dew point) Hot/wet measurement; ; Optional flow meter 06

07 Model 919 920 930 Analyzer Hot/wet single gas analyzer Hot/wet Multi-gas analyzer H 2 S in sulfur pit analyzer Dual beam, dual wavelength, Components SO 2, NO, NO 2, H 2 S, NH 3, CL 2, O 2 (Optional ZrO 2 detector) Range NH 3 : 0-125ppm-100%; CL 2 : 0-500ppm-100% SO 2, NO, NOx, H 2 S, NH 3, CL 2, COS, CS 2, O 2 (Optional ZrO 2 detector) NOx: 0-300ppm-100%; NH 3 : 0-125ppm-100%; CL 2 : 0-500ppm-100%; COS: 0-500ppm-100%; CS 2 : 0-500ppm-100% H 2 S, SO 2 H 2 S: 0-4%; SO 2 : 0-2% Response time T90<30 Seconds T90<30 Seconds T90<30 Seconds Precision ±1% Full Scale; O 2 : ±0.1% ±1% Full Scale; O 2 : ±0.1% ±1% Full Scale Repeatability <±0.5% Full Scale <±0.5% Full Scale <±0.5% Full Scale Calibration Manual or automatic Manual or automatic Manual or automatic Linearity ±1% Reading SO 2 : <±1% Reading; <±1% Reading NOx: <±1.5% Reading Noise <0.2% Full Scale <0.2% Full Scale <0.2% Full Scale Flow rate 3-5 L/Minute 3-5 L/Minute 3-5 L/Minute Sampling Aspirator Aspirator Aspirator Temperature and pressure With With With Analog output Four 4-20mA (self or loop powered) Four 4-20mA (self or loop powered) Four 4-20mA (self or loop powered) Communication One RS-422 Serial port (supports Modicon Modbus RTU), One RS-232 Serial port (typically reserved for configurator software). Optional ports are RS-485 (supports Modicon Modbus RTU) or RJ-45 Ethernet port (supports Modicon Modbus TCP/IP) Alarm Power 120/240 VAC ±10%, 47~63 Hz 120/240 VAC ±10%, 47~63 Hz 120/240 VAC ±10%, 47~63 Hz Power consumption 600 W 600W 600 W Instrument air >413.6 kpa,120 L/Minute >413.6 kpa,120 L/Minute >413.6 kpa,120 L/Minute Explosion proof area Enclosure NEMA 4* NEMA 4* Operation temperature 5~50 C 5~50 C 5~50 C Dimension H W D (mm) 1554 1118 306 1554 1118 306 1554 1118 306 Weight About 160 kg (350 lbs) About 160 kg (350 lbs) 160 kg (350 lbs) Installation Back panel Back panel Back panel Main applications CEM for Sulfur plant Wet scrubber (high water dew point) Multi component process streams CEM for Sulfur plant Wet scrubber (high water dew point) Multi component process streams Sulfur recovery Sulfur storage Sulfur de-gassing Hot/wet measurement; High precision, resolution and * To be installed in analyzer house Hot/wet measurement; High precision, resolution and

Model 931 932 933 Analyzer H 2 S analyzer (Acid Gas, TGTU) Multi-gas analyzer Dual beam, dual wavelength, highresolution, nondispersive UV high resolution, nondispersive UV/VIS Components H 2 S (Optional CO 2, H 2 ) SO 2, NO, NOx, H 2 S, NH 3, CL 2, COS, CS 2 (Optional CO 2, H 2 ) Range H 2 S: 0-4000ppm-100% NOx: 0-300ppm-100%; NH 3 : 0-125ppm-100%; CL 2 : 0-500ppm-100%; COS: 0-500ppm-100%; CS 2 : 0-500ppm-100% Low concentration H 2 S (COS, MeSH) analyzer Proprietary frontal elution; H 2 S, COS, MeSH (Optional CO 2 ) Standard range: H 2 S: 0-25-100ppm; COS: 0-100-500ppm; MeSH: 0-50-250ppm; Low range: H 2 S: 0-5ppm Response time T90<30 Seconds T90<30 Seconds H 2 S: T90<30 Seconds; COS: T90<60 Seconds; MeSH: T90<180 Seconds Precision ±1% Full Scale; H 2 : ±5% Full Scale ±1% Full Scale; H 2 : 5% Full Scale ±2% Standard range; ±5% Low range Repeatability <±0.5% Full Scale <±0.5% Full Scale ±2% Standard range Calibration Manual or automatic Manual or automatic Auto zero Linearity <±1% Reading <±1% Reading ±2% Reading Noise <0.2% Full Scale <0.2% Full Scale 1.0% Standard range Flow rate 2.5 L/Minute 2.5 L/Minute 2.5 L/Minute Sampling Depends on application Depends on application Sample gas: 830 kpag-13790 kpag Temperature and pressure Analog output Communication Alarm Constant temperature, Optional pressure Four 4-20 ma, 30 VDC Max; Four 1-5 VDC Constant temperature, Optional pressure Four 4-20 ma, 30 VDC Max; Four 1-5 VDC; Constant temperature, Optional pressure Four 4-20 ma, 30 VDC Max; Four 1-5 VDC One RS-232 Serial port (reserved for local use of configurator software), one RS-485 serial port (supports Modicon Modbus RTU), one RS-485 serial port (reserved for remote use of configurator software), optional RJ-45 Ethernet port (supports Modicon Modbus TCP/IP) 5 Independent sets of SPDT, Form C, potential-free relay contacts, 2A at 250 VAC 5 Independent sets of SPDT, Form C, potential-free relay contacts, 2A at 250 VAC 5 Independent sets of SPDT, Form C, potential-free relay contacts, 2A at 250 VAC Power 120/240 VAC ±10%, 47~63 Hz 120/240 VAC ±10%, 47~63 Hz 120/240 VAC ±10%, 47~63 Hz Power consumption 500W 500W 500 W Instrument air 30 psig above the process pressure, 30 L/Minute (for Division 2) 30 psig above the process pressure, 30 L/Minute (for Division 2) Explosion proof area Optional Class I, Division 2, Group A, B, C & D Optional Class I, Division 2, Group A, B, C & D Optional Class I, Division 2, Group A, B, C & D Enclosure Operation temperature 0~50 C 0~50 C 0~50 C Dimension H W D (mm) 1185 780 254 1185 780 254 1185 780 254 Weight 145 kg 145 kg 145 kg Installation Back panel Back panel Back panel Main applications SRU feed gas Acid gas Well head gas Sour gas pipeline Amine-based tail gas treating contactor overhead SRU feed gas Sulfuric acid production Amine-based tail gas treating Chemical reaction monitoring Gas sweetening Pipeline quality/custody transfer Synthetic natural gas (SNG) Blending stations Patented frontal elution technique; High resolution; Short response time 08

Model 914CEM 9000 RM 241 Analyzer Continous Emission Monitor Single or Multiple gas analyzer Hydrocarbon dew point analyzer UV, IR, Zirconium oxide, Automated chilled mirror Paramagnetic / VIS Components According to end user requirements SO 2, H 2 S, NO, NO 2, NOx, O 2 (Optional integral paramagnetic sensor) Hydrocarbon dew point Range SO 2 : 0-25ppm-100%; H 2 S: 0-50ppm-100%; NO: 0-50ppm-100%; NO 2 : 0-100ppm-100% Typically 60 C below the temperature at the analyzer installation Response time T90<30 Seconds Application dependent Precision ±1% Full Scale; O 2 : ±0.1% ±1 C Repeatability <±0.5% Full Scale; O 2 : ±0.1% ±0.4 C Calibration Manual or automatic Manual or automatic Linearity SO 2 : <±1% Reading; NO, NO 2, NOx, H 2 S: <±1.5% Reading; O 2 : ±0.1% Flow rate 0.94-4.7 L/Minute 0.25-5 L/Minute 1-5 L/Minute typically Analog output 2-6 isolated analog outputs, 0-20mA/4-20mA/0-5VDC 4-20mA Communication Modbus RTU RS-485 / Modbus TCP/Ethernet One RS-422/RS-485 Serial port (supports Modicon Modbus RTU), One RS-232 Serial port (reserved for configurator software). Optional RJ-45 Ethernet port (supports Modicon Modbus TCP/IP) Alarm 4 (expandable to 6) relay contacts 6 Status relay contacts Power 110/220/240 VAC 50-60 Hz 120/240 VAC ±10%, 47~63 Hz 240 VAC ±10%, 50 Hz, 120 VAC ±10%, 60 Hz Power consumption 300 W <275 W Explosion proof area General purpose; Class I, Division 2 General purpose; Class I, Division 2, Group A, B, C, D Class 1, Division 1, Group C & D; ATEX II 2 G EExd II B T4 Enclosure NEMA 4* NEMA 4* Operation temperature 7~49 C -20~50 C 10~40 C Dimension H W D (mm) 180 480 600 840 575 300 Weight 18.2 kg 60 kg Installation Back panel 19 Rack mount Back panel Main applications Stack gas Research Direct measure, single digit SO 2 CEMs Customized * To be installed in analyzer house Pipeline quality and custody transfer Specification monitoring Gas turbine feed gas monitoring Accurate monitoring of hydrocarbon dew points at pipeline or fixed pressure; Electricity is the only consumable 09