1 Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain fuel gases produced during crude oil refining and from natural gas. SRUs produce elemental sulfur and various gas waste streams. These waste streams must be destroyed to prevent environmental and health risks. Thermal oxidizers, or incinerators as they are also known, have been used for many years to oxidize remaining H 2 S, CO and other minor combustibles in these waste streams. This article discusses various particular design features of sulfur tail gas oxidizers. Waste Characterization/Emissions The primary waste stream from an SRU is the sulfur tail gas stream. There are other waste streams variously called pit vent, sweep air, etc. These other waste streams have very low mass flow compared to the tail gas stream and are not a major design consideration. These waste streams can be injected into the oxidizing chamber somewhere downstream of the burner. H 2 S, sulfur vapor, SO 2, COS and CS 2 in the waste is oxidized (or burned) in the thermal oxidizer to form SO 2 and a small amount of SO 3 in the flue gas. SOx in the flue gas is an environmental and a corrosion design concern. Unless the flue gas is treated with a downstream scrubber, which is very rare, all the SOx will exit the stack. Therefore, it is important to note that while a thermal oxidizer can control the amount of sulfur compounds mentioned above, it cannot control SOx emissions. The SOx emissions are completely determined by the sulfur content in the incoming waste. The primary purpose of a sulfur tail gas oxidizer is to destroy H 2 S because it is a highly toxic gas, even in low concentrations. The specified H 2 S emission limit from an oxidizer typically varies from 5 to 10 ppmv. Figure 1. Typical sulfur tail gas thermal oxidizer (base ring supported) In many cases, CO emissions limits are also specified. H 2 S is much easier to burn than CO. H 2 S autoignition temperature is 529 ºF (276 ºC). CO autoignition temperature is 1166 ºF (630 ºC). Emissions of CO are typically not guaranteed by an oxidizer manufacturer unless the operating temperature is above 1400 ºF (760 ºC). As with any combustion system, the higher the operating temperature, the lower the CO Page 1
2 emissions. However, a higher operating temperature can result in higher NOx emissions. Low NOx fired heater burner technology is frequently confused with the capability of a thermal oxidizer burner. Ultra-low NOx burner technology used for fired heaters can not be applied to burners for thermal oxidizers. The widely varying applications encountered in the supply of thermal oxidizers require a different design approach than that used for fired heater burners. For example, the use of flue gas recirculation for NOx reduction is vastly different for fired heater burners than for thermal oxidizer burners. Flue gas recirculation associated with fired heater burners is internal to the heater. However, flue gas recirculation associated with a thermal oxidizer would have to be external to the combustion chamber. The reason for external recirculation is due to the fact that the thermal oxidizer combustion chamber is lined with refractory (without a heat sink) eliminating the availability of cooled flue gas for internal flue gas recirculation. Figure 2. Comparison of fired heater burner and thermal oxidizer burner Only in thermal oxidizer applications utilizing a waste heat boiler downstream can one employ flue gas recirculation for NOx reduction in a thermal oxidizer external to the burner and oxidizer chamber. This is commonly known as, external flue gas recirculation. A slip stream of the flue gas downstream of the boiler can be recirculated back to the burner via a recycle fan. However, the ducting, electrical power usage, larger plot space required and more complicated burner make this approach quite expensive and therefore rare. The NOx emissions from a thermal oxidizer will depend on various factors such as the allowable CO emission limit, the CO content in the tail gas, the fuel gas composition, the waste gas composition and burner design. Typically, the NOx emissions will range from 0.06 to 0.1 pound of NOx per 1,000,000 Btu of heat released. Although flue gas recirculation cannot be used to lower NOx emissions, Callidus has developed a tool kit of thermal oxidizer burner design techniques over the years. All these methods involve a way to lower the flame temperature and may include such things as staged fuel gas combustion, water injection and steam injection. These techniques have been used for many years by several companies. Callidus also has several other proprietary techniques to reduce NOx levels. These designs involve the various ways tail gas can be used to cool the flame. Care must be taken in how tail gas is used to cool the flame. If the flame is cooled too much, CO emissions may increase. Experience, coupled with computational fluid dynamic modeling can result in designs that can lower NOx by 10 to 20% Page 2
3 aluminum or galvanized carbon steel and stands off from the shell by 3 to 6 inches (75 to 150 mm). This shroud also called a rain shield maintains a warm layer of slow-moving air between the shroud and the shell that keeps the steel hot but not as hot as external insulation. External insulation would result in temperatures beyond the oxidizing temperature of carbon steel. Figure 3. Typical tail gas incinerator burner Corrosion Due to the presence of SOx in the flue gas, care must be taken to prevent the steel shell of the oxidizer from getting below the dew point of the acid gas. Sulfuric acid can condense at very high temperature in flue gas. The acid gas dew point in the flue gas from a sulfur tail gas incinerator is typically between 300 and 350 ºF (177º C). Since thermal oxidizers furnaces are typically carbon steel with a castable or brick refractory lining, care must be taken to keep the steel temperature about 50 ºF (28 ºC) above the dew point in order to avoid corrosion from dew point condensation. If it is not possible to keep the above the dew point, a coal tar mastic lining or other high temperature acid resistant paint can be applied to the internal surface of the carbon steel shell before the refractory is installed. Although coatings are helpful, it only takes a small imperfection in the coating to allow acid to penetrate and cause corrosion. Therefore, maintaining the temperature of the steel above the dew point is the most reliable approach to prevent corrosion. To maintain steel shell temperature above SOx dew point, a thermal shroud is generally installed around the shell of the oxidizer. This shroud is typically Physical Orientation Oxidizers are usually vertical with horizontally fired burners. Due to the potential presence of liquid sulfur in the tail gas, the burner orientation is horizontal to allow the sulfur to drain into the bottom of the incinerator vessel. Vertical, up-fired burners are never recommended since the liquid sulfur could pool at the bottom of the chamber and fall into the combustion air plenum of the burner. Due to the presence of SOx in the flue gas, the stack outlet on sulfur tail gas oxidizers is typically 150 feet (46 meters) or more above grade. The height of the stack is dictated by a dispersion analysis for ground level concentration of SOx. Environmental regulations dictate acceptable ground level concentrations. In order to perform an accurate dispersion model analysis, knowledge of the surrounding terrain and adjacent structures is necessary. The stack and thermal oxidizer chamber are in many instances the same vessel. Stacks are typically self-supported by the base ring but in some cases are derrick supported. Some of the derrick supported designs will be less expensive but will require larger plot space and more time to assemble in the field. Page 3
4 For large capacity systems, the oxidizer chamber is horizontal. If a vertical design were used, it would result in fuel gas flame impingement on the refractory wall opposite the horizontally fired burner. This is especially true if the burner is natural draft since the flame will be longer than in a forced draft system. natural draft unit is lower than in a forced draft system. Combustion air turndown limits fuel gas burner turndown which limits tail gas turndown. Combustion air turndown in a natural draft unit is between 2:1 and 3:1 depending on the stack height. HI (High Intensity) Burners High intensity burners require high combustion air pressure drop, typically around 1.5 psig (10.3 kpa). The design causes the combustion air to swirl increasing turbulence downstream. This type of burner, although rarely used by tail gas incineration, is frequently used in applications in which it is important to have a short flame and excellent mixing such as in sulfur reaction furnaces and reheat burners. At least 50% of the sulfur tail gas incinerators that Callidus has provided over the last 20 years are natural draft. Both medium intensity burners (moderately high pressure drop) and natural draft burners (very low pressure drop) have been used in tail gas service over the years with much success. Figure 4. Tail gas incinerator with a flare Forced Draft vs. Natural Draft Burners can be natural draft or forced draft depending on turndown requirements and whether or not waste heat recovery equipment is located downstream. It is generally not acceptable to supply a natural draft burner for a system with heat recovery. The pressure drop of the flue gas through a superheater or waste heat recovery boiler is usually too great for natural draft alone to overcome. The combustion air turndown available in a While a typical forced draft system with a waste heat boiler might require a combustion air fan discharge pressure of 8 w.c. (2 kpa), the same system with an HI burner would require 60 w.c (15 kpa). 7.5 times the electrical power is needed to utilize a 400 HP (300 KW) motor instead of a 50 HP (38 KW) motor. Although most oxidizer manufacturers have the capability of providing both types of burners, the companies that promote HI burners for tail gas service only manufacture HI burners. In today s search for cost effective, low energy solutions, the HI Page 4
5 burner might not be the most economical solution. Stack Sample Ports Environmental regulations require sample ports be located after one second residence volume of the flue gas. This is measured from the centerline of the burner or the center line of the last waste gas nozzle to the center line of the sample port nozzle. Ideally, the sample ports should also be located in a straight run of stack, eight diameters downstream of last disturbance and at least 2 diameters from the exit or downstream disturbance. The disturbance is typically a transition in diameter of the stack. If this ideal arrangement is possible, then only two sample ports, located at 90 degrees around the circumference of the stack are required. In cases in which it is not possible to have eight diameters upsteam and two downstream, or in cases in which it is not economically feasible, it is acceptable to provide four sample ports oriented at 90 degrees around the circumference of the stack. Of course, in this case a 360 degree sample port access platform is required. If the ideal eight and two diameters cannot be provided, more samples are usually required during the stack test. Refractory The refractory lining can be low iron castable or brick. Brick refractory will provide longer life than castable. Fiber type refractory (ceramic fiber, board or modules) is not recommended. Acid gas will quickly destroy fiber type materials. In addition, fiber type refractory is too effective an insulator and will result in steel shell temperatures that are below the dew point, even with a rainshield. Heat Recovery Oxidizer chambers with heat recovery boilers are nearly always horizontal. Combustion air pre-heaters and waste gas pre-heaters are not recommended in a sulfur tail gas oxidizer system. When combustion air or waste gas is heated with the flue gas from the incinerator, the surfaces of the heat exchanger can become too cold on the flue gas side and can lead to acid gas condensation corrosion. Care must also be taken in the design of a waste heat recovery boiler to avoid corrosion. The flue gas exit temperature should not be so low that the flue gas could begin to condense on the stack surface downstream. Typically, the boiler exit flue gas temperature is maintained at 400 to 500 degrees F, depending on the boiler feed water temperature and the steam temperature needed to avoid corrosion. The stack downstream of a waste heat boiler is generally unlined carbon steel with external insulation. The external insulation insures that the flue gas remains hot enough to not condense out any SOx or H 2 O as it rises through the stack. Near the exit the flue gas will unavoidably be close to the dew point or below. To avoid corrosion at the exit, the top 3 to 10 feet of the stack is specified as stainless steel. Although occasionally considered, a flue gas bypass around the boiler is not recommended. The required bypass valve would be very large, expensive, prone to leak and could become a serious a maintenance problem. Fabrication and Design Codes Sulfur tail gas incinerators are typically designed to AISC or ASME code. The Page 5
6 operating pressure ranges from 1 or 2 inches water column vacuum to 8 to 10 inches water column positive pressure (in the case of a system with a waste heat boiler). ASME code design is not necessary at these pressures. However, some customers prefer ASME code for a sturdier design and higher quality fabrication. A cost effective compromise is to design per AISC but specify ASME fabrication. users with knowledge of design considerations important to the design of these systems. It should, also, allow suppliers to avoid designs or design consideration parameters that might adversely affect the reliability of these units. Some SRU licensors anticipate deflagration potential in the oxidizer. In such cases, the oxidizer chamber is frequently designed for 50 psig per ASME Code. Combustion Air Flow Measurement The best methods of measuring air flow due to its typically low pressure and high flow are: pitot tube array, thermal dispersion or annubar. A pitot tube array can be the most cost effective since it requires very few up- and down-stream diameters for a good measurement. If the air flow is very large, the number of duct diameters required by other devices can result in very large plot space requirement. Orifice plates are definitely not practical due to the high pressure drop required. A venturi meter can be used, but they are expensive, require more pressure drop (4 w.c. vs less than 1 w.c.) and take up more space compared to the recommended methods. Conclusion Tail Gas Incineration has been used as an effective means for disposal of waste gases produced in Sulfur Recovery Units. Information provided in this article will be of interest and benefit to both the user of this equipment and those supplying it. The article should provide Figure 5. Tail gas incinerator with heat recovery boiler Peter Pickard Chief Applications Engineer - Incineration Division Callidus Technologies by Honeywell 7130 South Lewis, #335 Tulsa, Oklahoma USA Operator Direct Line Mobile [email protected] Page 6
SULFUR RECOVERY UNIT. Thermal Oxidizer
SULFUR RECOVERY UNIT Thermal Oxidizer BURNERS FLARES INCINERATORS PARTS & SERVICE SULFUR RECOVERY UNIT Thermal Oxidizer Tail Gas Thermal Oxidizer designed and built to GOST-R requirements. Zeeco can meet
Presentation Outline. Background
Introduction ENVIRONMENTAL SYSTEMS, INC. Innovative Air Pollution Control Solutions Air Pollution Abatement Technologies for the Oil and Natural Gas Processing Industries. Jeff Kudronowicz / Application
TODAY S THERMAL OXIDIZER SOLUTIONS TO MEET TOMORROW S CHALLENGES
Callidus Oxidizers for Waste Destruction TODAY S THERMAL OXIDIZER SOLUTIONS TO MEET TOMORROW S CHALLENGES Thermal oxidizer systems Catalytic oxidizer systems Callidus, experts in Thermal Oxidizers Wide
Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems. Combustion Technology
Combustion Technology INNOVATIVE SOLUTIONS FOR COMBUSTION AND EMISSIONS CHALLENGES Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems Callidus Technologies by Honeywell - Experie
WATER WALL BOILER FOR AIR AND OXYGEN FIRED CLAUS SULPHUR RECOVERY UNITS
WATER WALL BOILER FOR AIR AND OXYGEN FIRED CLAUS SULPHUR RECOVERY UNITS Abstract Mahin RAMESHNI, P.E. Technical Director, Sulphur Technology [email protected] WorleyParsons 125 West Huntington
Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.
Steam Tables What They Are How to Use Them The heat quantities and temperature/ pressure relationships referred to in this Handbook are taken from the Properties of Saturated Steam table. Definitions of
Description of Thermal Oxidizers
Description of Thermal Oxidizers NESTEC, Inc. is a full service equipment supplier specializing in solutions for plant emission problems. The benefit in working with NESTEC, Inc. is we bring 25+ years
Condensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng
Condensing Economizers Workshop Enbridge Gas, Toronto MENEX Boiler Plant Heat Recovery Technologies Prepared by: Jozo Martinovic, M A Sc, P Eng MENEX Innovative Solutions May 15, 2008 MENEX INC. 683 Louis
High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR
High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR The heat transfer innovators. THE RELIANCE COPPER FINNED TUBE HYDRONIC BOILER FEATURES Copper Fin-Tube Heat Exchanger Up to 88% Thermal
HOW TO SELECT A LOW VOLUME (L.V ) BOILER
HOW TO SELECT A LOW VOLUME (L.V ) BOILER FREQUENTLY ASKED QUESTIONS OR COMMENTS ON BOILERS Dear Potential Customer: Low Volume Operator Exempt boilers have been marketed in Ontario to eliminate the requirement
The soot and scale problems
Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications
Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE
Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance
ELECTRODE BOILERS VAPOR POWER INTERNATIONAL
ELECTRODE BOILERS WITH JET-FLO Technology VAPOR POWER INTERNATIONAL ELECTRODE boilers The Electrode Steam Boiler with Jet-Flo technology consists of an insulated pressure vessel and is fully enclosed in
Originators of the Flexible Water Tube design
BRYAN FLEXIBLE WATER TUBE AB SERIES STEAM AND WATER BOILER 900,000 TO 3,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Water Boiler AB120-W-FDGO Steam Boiler AB250-S-150-FDG Originators of the Flexible
Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH
Centauri Condensing Fire Tube Water Boiler 399 to 1000 MBH Pre-mix surface burner with up to a 7-to-1 turndown NOx levels as low a 5 ppm at full rate Operates on 4" gas pressure shown with optional gauges
Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas
Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas Mark Schiffhauer, ATSI Engineering Services Cameron Veitch, Combustion and Energy Systems Scott Larsen, New York State Energy
CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2
WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials
INDEX 9-7-100 GENERAL
REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL AND COMMERCIAL BOILERS, STEAM GENERATORS AND PROCESS HEATERS INDEX 9-7-100 GENERAL 9-7-101
Energy Efficient Operations and Maintenance Strategies for Boilers
Energy Efficient Operations and Maintenance Strategies for Boilers Large, complex and widely used, industrial boilers are major consumers of fuel. Proper operations and maintenance (O&M) procedures must
steam centre of excellence Steam Boiler System Optimization
Steam Boiler System Optimization Introduction Gas Cost Metering Fluids Fuel, Water, Steam Steam Costs Boiler House Stack Losses Boiler Waterside Surfaces Blowdown Current Natural Gas Cost Projected Cost
Natural Gas Conversions of Existing Coal-Fired Boilers
White Paper MS-14 Natural Gas Conversions of Existing Coal-Fired s Authors: F.J. Binkiewicz Jr., P.E. R.J. Kleisley B.E. McMahon J.E. Monacelli D.A. Roth D.K. Wong Babcock & Wilcox Power Generation Group,
F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems
F ox W hi t e Paper Reduce Energy Costs and Enhance Emissions Monitoring Systems A Technical White Paper from Fox Thermal Instruments Rich Cada, VP Sales & Marketing, Fox Thermal Instruments, Inc. 399
Evaluating Thermal & Catalytic Oxidation Technology for VOC, HAP & Odor Abatement. John Strey
Evaluating Thermal & Catalytic Oxidation Technology for VOC, HAP & Odor Abatement John Strey Experience Installing Quality Equipment Since 1987 Over 3,000 Air Abatement Systems Installed Worldwide Unbiased
Chapter. Flares and Stacks. Flares (FLR)... 16-3. Stacks (STK)... 16-9. G2 ICARUS Corporation, 1998.
Chapter 16 Flares and Stacks Flares (FLR)... 16-3 Stacks (STK)... 16-9 G2 ICARUS Corporation, 1998. 16-2 ICARUS Reference ICARUS Corporation, 1998. G2 Chapter 16: Flares and Stacks 16-3 Flares (FLR) A
PMI-IF-H High Efficiency Gas Heat Units
PMI-IF-H High Efficiency Gas Heat Units Mechanical High Efficiency Gas Fired Make-Up Air Units Price s new line of high efficiency indirect fired gas heating products are designed to meet the goals of
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
IVISIONS STEAM PLANT DIVISIONS TOTAL TURNKEY SOLUTIONS. INDUSTRIAL BOILER & MECHANICAL
IVISIONS INDUSTRIAL BOILER & MECHANICAL STEAM PLANT DIVISIONS TOTAL TURNKEY SOLUTIONS. FIELD SERVICE & REPAIR DIVISION Rely on IB&M's field service experts for your steam plant. Our Field Service & Repair
Commercial Gas Water Heaters
POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600
INTEC Engineering GmbH Heating Solutions for the Marine Industry
INTEC Engineering GmbH Heating Solutions for the Marine Industry Thermal Oil Heaters Heating Solutions for the Marine Industry Compared to conventional plants using hot water or steam, thermal oil as a
Control Device Requirements Charts For Oil and Gas Handling and Production Facilities
Device Charts For Oil and Gas Handling and Production Facilities Purpose/Scope: The purpose of this document is to provide standardized guidance for use by the regulated community and air permit reviewers,
BOILER SELECTION CONSIDERATIONS
BOILER SELECTION CONSIDERATIONS CONTENTS Definitions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Combustion Pulsation and Noise by Dan Banks, P.E., Banks Engineering Inc.
Combustion Pulsation and Noise by Dan Banks, P.E., Banks Engineering Inc. Posted: August 1, 2007 The natural flame instability in any flare or furnace produces noise. In rare cases, the noise can be loud
Continuous flow direct water heating for potable hot water
Continuous flow direct water heating for potable hot water An independently produced White Paper for Rinnai UK 2013 www.rinnaiuk.com In the 35 years since direct hot water systems entered the UK commercial
Overview of Waste Heat Recovery for Power and Heat
Overview of Waste Heat Recovery for Power and Heat Dave Sjoding Northwest Clean Energy Application Center Washington State University Extension Energy Program Waste Heat Recovery for Power and Heat Workshop
Maximizing Boiler Plant Efficiency. Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc.
Maximizing Boiler Plant Efficiency Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc. Efficient Boiler Design Boiler Types Efficiency Definition Non-Condensing Condensing Maximizing Efficiency
UDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance
Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance The Boiler MACT, 40 CFR 63, Subpart DDDDD, was vacated in 2007 by the U.S Court of Appeals and the 2004 rule
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
Commercial Boiler Systems and Controls
Commercial Boiler Systems and Controls Condensing Non-condensing Hybrid Systems Steel Medium Mass Copper Instantaneous Electric Riverside R HYDRONICS An introduction to hybrid boiler systems What is a
I. STEAM GENERATION, BOILER TYPES
I. STEAM GENERATION, BOILER TYPES and BOILER PLANT SYSTEMS 1 Steam Generation Water s Unique Properties: High Thermal Capacity (Specific Heat) High Critical Temperature Ideal Medium for Heat Delivery High
Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin
Drying of Woody Biomass BioPro Expo & Marketplace / Atlanta, GA / March 14-16, 2011 Drying of Woody Biomass Conventional Direct Fired Dryer Technology Proprietary work of the Copyright Owner Issues with
HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS
HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS William K. Scullion, Application Engineering Leader, MEGTEC Systems, De Pere, WI Introduction Competitive pressures continuously motivate us to examine our
Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank
Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank Unbiased, Third-Party, Water & Energy Management Consulting Firm: - Not affiliated
Less Exhaust Gas Less Pollution More Dollar Savings
Less Exhaust Gas Less Pollution More Dollar Savings CASE STUDIES Dow Corning - RTV Silicone Plant ConDex System utilized to heat boiler make up water from 50 F up to 180 F with recovered energy from boiler
Commercial Gas Water Heaters
CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable
Condensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
Commercial Gas Water Heater
Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service
INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9
TABLE OF CONTENTS Description Page Number SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9 Indeck Keystone Energy, LLC. 5451 Merwin Lane, Suite 100 Erie,
Gas-Fired, Residential Storage Type Water Heaters
Consulting, Resource, Education, Training, and Support Services for Home Inspectors A candle loses no light when it lights another candle. Gas-Fired, Residential Storage Type Water Heaters Most inspectors
Desuperheater Online Program Sizing Guidance
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
IGEMA BOILER LEVEL & TDS CONTROLS
IGEMA BOILER LEVEL & TDS CONTROLS IGEMA offers boiler level and TDS control products of the highest quality standard, being certified to ISO 9001. Made in Germany, IGEMA products are manufactured in compliance
Some Criteria for Choosing a Steam Boiler for a Microbrewery
Some Criteria for Choosing a Steam Boiler for a Microbrewery Jack Coe Rite Engineering and Manufacturing Corporation Breweries rely on steam heating for a number of functions, primarily to heat the brew
Rules for construction of heating boilers, Boiler and Pressure Vessel Code, Section IV-2007
Boilers Introduction How Boilers Work Types of Boilers Key Components of Boilers Safety Issues Best Practices for Efficient Operation Best Practices for Maintenance References Introduction Boilers are
Case History: Ethanol Facility Retrofit with a Lower Emissions, Improved Fuel Efficiency Thermal Oxidizer and Dryer Burners
Case History: Ethanol Facility Retrofit with a Lower Emissions, Improved Fuel Efficiency Thermal Oxidizer and Dryer Burners Control # 1074 Prepared by L. Crynes, P. Melton, H. Hohl, C. Baukal, M. Lorra,
R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler
[N.2.1.1] R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler (Environment-Friendly, High-Efficiency Boiler Group) Takashi Murakawa, Yasuhiro Kotani, Kazuhiro Kamijo, Koichi Tsujimoto, Hiroshi
Thermal Dispersion Mass Flow
Thermatel Thermal Dispersion Mass Flow Measurement Handbook Table of Contents Introduction...1 What is Mass Flow Measurement?...1 Types of Flow Transmitters...4 Differential Pressure...4 Orifice...4 Venturi...6
Commercial Gas Water Heaters
UP TO 96% THERMAL EFFICIENCY, DIRECT-VENT FEATURES TM BTH-120 through BTH-500 The A. O. Smith Cyclone Xi family of products represents the industry s most technologically advanced commercial water heaters.
Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation
Steam Generator Boilers Compact Steam Boilers Rapid Start-Up Safe in Operation AB&CO TT BOILERS The boiler maker AB&CO TT BOILERS LTD. have since the middle sixties produced industrial boilers and heaters
Boiler NOx Emissions and Energy Efficiency
Boiler NOx Emissions and Energy Efficiency Prepared For: Boiler Operators and Facility Managers Prepared By: 100 Montgomery Street, Suite 600 San Francisco, CA 94104 AGENDA Introduction Boiler NOx Formation
COMBUSTION. By: Michael Biarnes. In collaboration with: Bill Freed and Jason Esteves. E Instruments International LLC - www.e-inst.
COMBUSTION By: Michael Biarnes In collaboration with: Bill Freed and Jason Esteves E Instruments International LLC - www.e-inst.com 1 Combustion What is Combustion? Combustion takes place when fuel, most
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS
TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS Dr. Abhay Kumar Sahay, AGM(CC OS) Bijay Manjul, AGM( Operation) Kahalgaon Boiler has three inputs Steam generator 1. WATER 2. COAL 3. AIR Burner Air preheater
Steam Generation Efficiency Module Blowdown Losses Section
Steam End User Training Steam Generation Efficiency Module Blowdown Losses Section Slide 1 Blowdown Losses Module This section will discuss blowdown loss and its affect on boiler efficiency. [Slide Visual
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
Recover Heat from Boiler Blowdown Water
Prepared for California Energy Commission (CEC) Prepared By: Southern California Gas Company (A Sempra Energy Utility) E3M Inc. May 2012 i Disclaimer The CEC and its contractor, Southern California Gas
Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY
Biomass Boiler House Best Practices Irene Coyle & Fernando Preto CanmetENERGY Growing the Margins London, Ontario March 2010 The Biomass & Renewables Group of Industrial Innovation Group (IIG) of CanmetENERGY
Energy Saving Solutions. Bob Montgomery Technical Solutions Specialist Waterloo Manufacturing
Energy Saving Solutions Bob Montgomery Technical Solutions Specialist Waterloo Manufacturing Combustion Efficiency Measure Heat Recovery Energy Saving Solutions Upgrade Repair Replace Audits Financial
Steam System Efficiency. Bill Lumsden Leidos Engineering
Steam System Efficiency Bill Lumsden Leidos Engineering Steam System Efficiency Steam System Efficiency Key Take-aways: Review of the properties of ice, water, and steam Learn the basics of steam trap
Introduction to Computational Fluid Dynamics (CFD) for Combustion. www.reaction-eng.com (801) 364-6925
Introduction to Computational Fluid Dynamics (CFD) for Combustion www.reaction-eng.com (801) 364-6925 What is CFD? CFD stands for Computational Fluid Dynamics CFD uses computers to represent (or model)
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
Committed to make a better world
Committed to make a better world 1. Higher Availability & Reliability 2. Highest Plant efficiency 3. Lower Heat Rate 4. Minimum Auxiliary Power Consumption 5. Minimum Emission of Pollutants Committed to
CHAPTER 5 WATER HEATERS
PlumbingCode06_ch05 5/29/06 8:12 AM Page 1 CHAPTER 5 WATER HEATERS Water heaters are only a small portion of a plumbing system, but they are important, and they can be dangerous. Many plumbers take water
BEST PRACTICE GUIDE. Energy Efficiency: Steam, Hot Water and Process Heating Systems
BEST PRACTICE GUIDE Energy Efficiency: Steam, Hot Water and Process Heating Systems Contents 1 Introduction 4 2 The business benefits of steam system, hot water system and process heating system efficiency
UNDERSTANDING CENTRAL HEATING SYSTEMS
UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic
Test Code: 8297 / Version 1
Blueprint HVAC Maintenance Technology PA Test Code: 8297 / Version 1 Copyright 2014. All Rights Reserved. General Assessment Information HVAC Maintenance Technology PA Blueprint Contents General Assessment
C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).
SECTION 23 52 30 PART 1 - GENERAL 1.01 RELATED WORK A. Section 23 05 00: Common Work Results for HVAC B. Section 23 25 00: Chemical Water Treatment C. Section 23 51 23: Flue Piping 1.02 QUALITY ASSURANCE
OROT RABIN POWER STATION UNITS 1-4. 4 x 350 MW
ISRAEL ELECTRIC OROT RABIN POWER STATION UNITS 1-4 4 x 350 MW COAL BOILER CONVERSION TO LOW NO X NATURAL GAS AND COAL FIRING BY PRIMARY AND SECONDARY MEASURES INSTALLATION Replacing the Burner Management
Multi-pollutant control solutions for coal based power plants
Multi-pollutant control solutions for coal based power plants By Luca Mancuso and Hans Janssen Content SOx control Wet Scrubbers Open towers Dual Flow Tray Technology Semi-Dry SDA CFB Scrubbers Dust control
www.garrisonwaterheaters.com Electric & Gas Water Heaters
www.garrisonwaterheaters.com Electric & Gas Water Heaters Hot Water: Take it for Granted with Garrison According to the U.S. Department of Energy, the average American home uses 64 gallons of hot water
Best Practice in Boiler Water Treatment
Best Practice in Boiler Water Treatment Boiler Water Treatment Part 2 Internal Treatment Objectives of Internal Water Treatment 1 To control the level of total dissolved solids (TDS) within the boiler
Efficiency on a large scale CFB Steam Boilers
Efficiency on a large scale CFB Steam Boilers Circulating Fluidized Bed Steam Boiler The Circulating Fluidized Bed Steam Boiler is an offering from Bosch Thermotechnology a member of the worldwide Bosch
Indirect fired heaters
Indirect fired heaters Indirect Fired Heaters General INDIRECT BATH HEATERS have a wide variety of successful applications in the oil and gas production, processing and transmission industry. Some of the
COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.
COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?
Low Emission - Low Maintenance Burner Design
Reliability & Maintenance Conference & Exhibition May 24-27, 2005 Ernest N. Morial Convention Center New Orleans, Louisiana Low Emission - Low Maintenance Burner Design Presented By: Scott D. Reed Vice
QUADRANT SR- Thermal Oxidizer Process Design & Environmental Control Benefits for the Sand Coating Industries
> 99% VOC, HAP & CO Destruction Efficiency Time, temperature and turbulence are the basic design principles required for organic pollutant control. In the QUADRANT-SR SERIES Recuperative Thermal Oxidizers,
5.2. Vaporizers - Types and Usage
5.2. Vaporizers - Types and Usage 5.2.1. General Vaporizers are constructed in numerous designs and operated in many modes. Depending upon the service application the design, construction, inspection,
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
THE OPTIMISATION OF BIOMASS COMBUSTION IN SMALL BOILERS
The optimisation of biomass INFRASTRUKTURA I EKOLOGIA TERENÓW WIEJSKICH INFRASTRUCTURE AND ECOLOGY OF RURAL AREAS Nr 6/28, POLSKA AKADEMIA NAUK, Oddział w Krakowie, s. 63 69 Komisja Technicznej Infrastruktury
CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.
Lanair Clean Burn CABINET Lanair's lightweight heat exchanger provides very little travel for the heat to be picked-up and ultimately be transferred to your shop. It uses a 2-pass design made up of 12
Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla
Helsinki University of Technology Department of Mechanical Engineering Energy Engineering and Environmental Protection Publications Steam Boiler Technology ebook Espoo 2002 Boiler Calculations Sebastian
A basic introduction to steam
A basic introduction to steam FOR HOT, COLD, MOIST AND DRY, FOUR CHAMPIONS FIERCE. STRIVE HERE FOR MASTERY Milton 1666 Steam Wonderful Steam Very high heat content Recyclable Clean, non toxic Biodegradable
MOSS WOOD BOILER SYSTEMS
GEORGE K. MOSS CO., INC. INSIDE THIS ISSUE: WOOD WATER T U- TUBE BOILER WOOD FIREBOX BOILER WOOD HYBRID BOILER GASIFIER COM B- BUSTION SYS- TEM PNEUMATIC COMBUSTION SYSTEM WOOD BOILER PLC CONTROLS PLC
Fired Heater Design and Simulation
Fired Heater Design and Simulation Mahesh N. Jethva 1, C. G. Bhagchandani 2 1 M.E. Chemical Engineering Department, L.D. College of Engineering, Ahmedabad-380 015 2 Associate Professor, Chemical Engineering
Steam System Best Practices Condensate System Piping
Steam System Best Practices Condensate System Piping Summary The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum
ALUMINUM. BestPractices Assessment Case Study. Alcoa North American Extrusions Implements Energy Use Assessments at Multiple Facilities.
ALUMINUM BestPractices Assessment Case Study August 2001 OFFICE OF INDUSTRIAL TECHNOLOGIES ENERGY EFFICIENCY AND RENEWABLE ENERGY, U.S. DEPARTMENT OF ENERGY BENEFITS Assesses core systems commonly found
Mechanical Rooftop Custom Capabilities
Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition
NFPA31FuelOilPiping 1 Revised 3-1-11
NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from
Element D Services Plumbing
PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses domestic cold, hot and hot water return distribution systems within and to five feet beyond building perimeter. PART 2 - DESIGN CRITERIA 2.01 GENERAL