MERCOFRIO 2000 CONGRESO DE AR CONDICIONADO, REFRIGERACAO, AQUACIMENTO E VENTILACAO DE MERCOSUL

Similar documents
PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

UNIT 2 REFRIGERATION CYCLE

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Waste Heat Recovery through Air Conditioning System

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

FEASIBILITY OF A BRAYTON CYCLE AUTOMOTIVE AIR CONDITIONING SYSTEM

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

Thermodynamics - Example Problems Problems and Solutions

Model-Based Approach for Optimizing a Data Center Centralized Cooling System

Heat Recovery In Retail Refrigeration

Characteristics of Evaporators

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler

UNDERSTANDING REFRIGERANT TABLES

SIMULATION OF THERMODYNAMIC ANALYSIS OF CASCADE REFRIGERATION SYSTEM WITH ALTERNATIVE REFRIGERANTS

Testing methods applicable to refrigeration components and systems

Experimental Analysis of a Variable Capacity Heat Pump System Focusing on the Compressor and Inverter Loss Behavior

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

Increasing the evaporation temperature with the help of an internal heat exchanger

Chapter 3.4: HVAC & Refrigeration System

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Analysis of Ammonia Water (NH3-H2O) Vapor Absorption Refrigeration System based on First Law of Thermodynamics

Development and testing of a multi-type air conditioner without using AC inverters

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

Mohan Chandrasekharan #1

Refrigeration Basics 101. By: Eric Nelson

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

An analysis of a thermal power plant working on a Rankine cycle: A theoretical investigation

Research on the Air Conditioning Water Heater System

How To Know If A Refrigeration System Is Efficient

How To Calculate The Performance Of A Refrigerator And Heat Pump

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

Validation of a vapour compression refrigeration system design model

Optimal operation of simple refrigeration cycles Part I: Degrees of freedom and optimality of sub-cooling

EFFECTS OF INDOOR RELATIVE HUMIDITY ON REFRIGERATED DISPLAY CASE PERFORMANCE

ME 201 Thermodynamics

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

How To Design A Refrigeration System

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

Energy Analysis and Comparison of Advanced Vapour Compression Heat Pump Arrangements

REFRIGERATION (& HEAT PUMPS)

HVAC Efficiency Definitions

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Condensers & Evaporator Chapter 5

POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

The Development of a Frost-Less Heat Pump

Energy savings in commercial refrigeration. Low pressure control

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

High Pressure Ammonia Systems New Opportunities

The maximum coefficient of performance of internally irreversible refrigerators and heat pumps

How Ground/Water Source Heat Pumps Work

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

C H A P T E R 8 REFRIGERATION AND AIR CONDITIONING

Analytical Study of Vapour Compression Refrigeration System Using Diffuser and Subcooling

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Guidelines of how to instrument, measure and evaluate refrigeration systems in supermarkets PAU GIMÉNEZ GAVARRELL

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

Transient Analysis of Integrated Shiraz Hybrid Solar Thermal Power Plant Iman Niknia 1, Mahmood Yaghoubi 1, 2

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential

The Second Law of Thermodynamics

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

Dynamic Simulation of a Variable-Speed Ground-Coupled Liquid Desiccant Air-Conditioner for Use in Subtropical Regions

HVAC and REFRIGERATION

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Chapter 10: Refrigeration Cycles

Why and How we Use Capacity Control

Cooling Load Calculation

Optimal operation of an Ammonia refrigeration cycle

We will try to get familiar with a heat pump, and try to determine its performance coefficient under different circumstances.

Open Cycle Refrigeration System

Integration of a fin experiment into the undergraduate heat transfer laboratory

Air Water Vapor Mixtures: Psychrometrics. Leon R. Glicksman c 1996, 2010

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Purpose of Refrigeration

DESIGN OF AIR CONDITIONING SYSTEM IN AUTOMOBILE

42-Volt Electric Air Conditioning System Commissioning and Control For a Class-8 Tractor

Theoretical and Numerical Analysis of Heat Transfer in Pipeline System

Creating Efficient HVAC Systems

OPTIMIZATION OF DIAMETER RATIO FOR ALPHA-TYPE STIRLING ENGINES

How does solar air conditioning work?

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES

HVAC Systems: Overview

AIR CONDITIONING TECHNOLOGY

KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO. SAUDI STANDARD DRAFT No. 3457/2005

HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS

Experimental Analysis of an Automotive Air Conditioning System With Two-Phase Flow Measurements

Todd M. Rossi, Ph.D. President

The HVAC Service Assistant

Transcription:

MERCOFRIO 2000 CONGRESO DE AR CONDICIONADO, REFRIGERACAO, AQUACIMENTO E VENTILACAO DE MERCOSUL Luis Rosario, Ph.D. rosariol@ing.ula.ve Department of Mechanical Engineering Facultad de Ingenieria Av. Don Tulio Universidad de Los Andes Mérida, Venezuela A SIMPLIFIED EXPERIMENTAL MODEL TO SIMULATE AN AIR CONDITIONER Abstract. A simplified model based on experimental data has been developed to be used in airconditioning systems simulations. Cycle thermodynamic relationships, along with experimental data, were used to mathematically model the air-conditioning system. Characteristic parameters of the equipment were determined from the results of a limited number of testing points. The following parameters were used: the clearance factor C, the piston displacement PD, the efficiency of the compressor η comp, the sensible heat factor SHF and the product of the overall heat transfer coefficient times area (UA value) for the heat exchangers. Component performance simulation data was validated using experimental data from a 3 ton air conditioner. The model calculates the following parameters: coefficient of performance (COP), system capacity (q e ), system heat rejection (q c ) and compressor power (W) at any operating condition. A heat exchanger performance model was developed using overall heat transfer coefficients and first law energy balance principles. A semi-empirical compressor model developed by Popovic and Shapiro (1995) was incorporated to the air-conditioner simulation. The simulation model consists of heat exchanger energy balance relationships for the evaporator, condenser, expansion device and compressor model. The purpose of the model is to reduce the amount of experimental data needed to characterize a system while keeping an acceptable level of accuracy in predicting its performance. The model predicted system heat rejection (q c ) and system capacity (q e ) within 10% of experimental data. The required compressor power (W) was predicted within 5% of uncertainty. However, the coefficient of performance (COP) had an uncertainty slightly higher than ±13% when compared to experimental data. These ranges of uncertainty are quite acceptable for experimental models. These differences relate to equipment characterization of the current model, which is determined from the results of a few testing points. The accuracy of the model is quite acceptable, despite the simplifying assumptions. An additional advantage is the use of the simulation model in equipment certification minimizing the required number of testing points. Key Words : Air Conditioning, Systems Simulation, Modeling Symbols A Curve-fitting coefficients for polytropic exponent dependence on compression ratios

C Clearance factor c p Specific heat, kj/kg o K f Thermodynamic property of refrigerant at saturation temperature h Specific enthalpy, kj/kg m Mass flow rate, kg/s m c Condenser air mass flow rate, kg/s m e Evaporator air mass flow rate, kg/s n Polytropic exponent P Pressure, kpa PD Piston displacement volume, m 3 q Rate of heat transfer, W SHF Sensible heat factor T Temperature, o C v Specific volume, m 3 /kg W Energy rate (power), kw UA Overall heat transfer coefficient, W/ o K Greek Symbols η Efficiency ϕ Thermodynamic property of refrigerant at saturation temperature ψ Thermodynamic property of refrigerant at saturation temperature θ Thermodynamic property of refrigerant at saturation temperature Subscripts c Condenser ci Air side condenser inlet comp Compressor e Evaporator ei Air side evaporator inlet dis Discharge, state of refrigerant leaving the compressor ref Refrigerant suct Suction, state of refrigerant entering the compressor Introduction The performance of an air conditioner depends not only on the performance of its individual components but also on how they interact. The intricate relationships among components are linked to operating conditions and design parameters. Due to this complexity, it is too expensive and time-consuming to perform field experiments to determine the effects of all possible changes either in the components or in the operating conditions on the performance of the air conditioner. As a result, computer models are used to predict system response to changes in sizing, materials, ambient conditions, etc. Model Description The pressure-enthalpy diagram in figure 1 shows the standard vapor-compression cycle. Process is as follows: isentropic compression of saturated vapor (state point 1) to the condenser

pressure (state point 2). Change of phase at constant presuure inside the condenser (2 to 3). Saturated liquid leaves the condenser (state point 3) and, expands at constant enthalpy to gas at evaporator pressure (state point 4). Evaporation at evaporator pressure to saturated vapor (state point 1). Pressure (KPa) 3 4 EXPANSION CONDENSATION EVAPORATION 1 2 COMPRESSION Enthalpy (kj/kg) Figure 1. Pressure enthalpy diagram of the standard vapor compression cycle In order to reduce the complexity of the model the following simplifying assumptions are made: Steady-state operation (same mass flow of refrigerant in any part of the loop). Pressure drops are neglected, except at the expansion valve. No subcooling takes place at the condenser outlet. There is no superheating at the evaporator outlet. Compression is a polytropic process. The polytropic exponent is a function of the refrigerant type and compression ratio only. Lubricating oil has negligible effects on refrigerant properties and compressor operation. There are no pressure drops at the compressor suction and discharge lines. Refrigerant charge effects are neglected. Compressor An exact analytical model of a reciprocating compressor is extremely complex. There are two different compressor models for system simulation. The first compressor model requires a compressor performance chart. These charts are generated by a manufacturer for a fixed superheat, and curve-fitted to compressor inlet and outlet temperatures (Fisher and Rice (1983)). In the second model, the compressor performance is modeled through a control volume approach in which the overall energy transfer is evaluated. Reciprocating and centrifugal compressors have been modeled using this approach with very good results (Popovic and Shapiro (1995); Popovic and Shapiro (1998)). This semi-theoretical model is based upon displacement, operational speed, volumetric efficiency and isentropic efficiency. The refrigerant flow rate through the compressor can be expressed as:

m ref PD C C P dis = + vsuct 1 Psuct 1/ n (1) This equation shows that the refrigerant mass flow rate depends on compressor geometry, compression ratio, refrigerant type (through the polytropic exponent), and the condition of the refrigerant vapor at the beginning of compression. Popovic and Shapiro (1995) analyzed extensive experimental data and proposed a model for the polytropic exponent as a function of the refrigerant type and compression ratio. This function is of the following form: A n = A1 + P P dis suct A + 2 (2) Pdis P 2 3 The coefficients used in this equation for various refrigerants are shown in table 1. Table 1. Coefficients for polytropic exponents as a function of the compression ratio for various refrigerants suct Refrigerant A 1 A 2 A 3 R-22 1.2094-0.2931 0.7802 R-134a 1.0428 0.1270 0.1603 MP-39 1.0022 1.1272-1.5753 MP-52 1.0627 0.4177-0.0991 R-12 0.9975 0.8477-0.5327 The enthalpy balance for the compressor is given by: n 1 n P n dis h2 h1 = Psuct vsuct 1 n 1 Psuct (3) For an isentropic compression process, under steady state conditions, the compressor power is given by: Wcomp = mref ( h2 h1 ) (4) The actual compressor power required can be found by dividing the isentropic power by the compressor efficiency: W W comp = η (5) comp Evaporator Model A wide range of models for heat exchangers are currently available, and can be differentiated by the degree of complexity and empiricism incorporated. Most of them are highly empirical and require few geometric specifications (Rabehl et al (1999)). There are two methods

of heat exchanger analysis that are commonly used. One, the log-mean-temperature-difference method, is extensively used in the process industries; the other, the effectiveness-ntu (Number of Transfer Units) method is more often employed for gas-flow heat exchangers, especially in thermal power systems (Incropera and Dewitt (1996); Kays and London (1984)). Our model uses the first scheme to simulate heat exchanger performance. It is possible to derive a set of equations representing the fluid heat transfer when one of the fluids flowing through a heat exchanger changes phase. This fluid will remain at a constant temperature, provided that its pressure does not change. As air moves across the evaporator its temperature decreases from T ei to T eo while the refrigerant temperature, T e, remains constant. The characteristic shape of the temperature curves of the two fluids is shown in figure 2 Tei Temperature Te Teo Area Figure 2. Fluid temperature variation in an evaporator The cooling and dehumidifying processes that take place in the evaporator involve both sensible and latent heat transfer. The total heat is the sum of both the sensible and latent heats. The sensible heat ratio is defined as the ratio between the sensible heat and the total heat across the evaporator. From a refrigerant energy balance on the evaporator, the energy given by the refrigerant can be expressed as: qe = mref ( h1 h4 ) (6) The evaporator refrigerant temperature can be found from an air-side heat balance on the evaporator and can be expressed as: qe SHF Te = Tei ( UA) e me cp (7) 1 exp me cp The suction pressure corresponds to the saturation pressure at the evaporator refrigerant temperature: P = f T (8) suct ( ) e

and the suction specific volume is also a function of the evaporator temperature: vsuct = ϕ ( Te ) (9) The refrigerant enthalpy at the evaporator exit is a function of the saturation temperature: h 1 = ψ ( T e ) (10) Condenser Model The condenser model is a very simple approach similar to that of the evaporator model. The fluid will then remain at a constant temperature, provided that its pressure does not change. As air moves through the condenser its temperature increases from T ci to T co, while the refrigerant temperature, T c, remains constant. The fluid temperature profiles for the condenser are shown in figure 3. These profiles are valid only in the condensing zone of the condenser and not in the desuperheating and subcooling zones. Stoecker and Jones (1982), however report that this representation of the heat exchanger provides reasonably accurate results throughout the entire condenser. The condenser refrigerant temperature can be found from an air-side heat balance on the condenser and can be expressed as: qc Tc = Tci + ( UA) c mc cp (11) 1 exp mc cp The discharge pressure corresponds to the saturation pressure at the condenser refrigerant temperature: Pdis = f( Tc ) (12) From a refrigerant energy balance on the condenser, the energy absorbed by the refrigerant can be expressed as the refrigerant mass flow rate times a change in enthalpy of the refrigerant. qc = mref ( h 2 h 3 ) (13) Expansion Device In predicting system performance so far it has tacitly been assumed that the expansion device is able to regulate the flow of refrigerant into the evaporator so that the heat transfer surfaces on the refrigerant side of the evaporator are wetted with liquid refrigerant. Saturated liquid is entering our expansion device. Assuming that there is no heat transfer or external work. h 3 = ψ ( T c ) (14) Finally, the process from state 3 to state 4 through the expansion device is assumed to be isoenthalpic h4 = h3 (15) The vapor compression system can be now modeled by the steady state representation of each of its components. This steady state model yields to a set of 15 equations with 15 unknowns. These unknowns are: m, v, P, P, n, h, h, h, h, W, W, q, q, T, T ref suct suct dis 1 2 3 4 comp e c e c

Temperature Tc Tco Area Figure 3. Fluid temperature distribution in a condenser These 15 equations are nonlinear, and they will be solved simultaneously and numerically. However, the equations include certain parameters that need to be determined before a solution can be sought. These parameters are: for the compressor C, PD,η comp and for the heat exchangers SHF,( UA),( UA) Results Tci e c Component performance was validated using experimental data from a 3 ton air conditioner unit based upon the test data taken by Rosario (1999). Characteristic parameters of the equipment were determined from the results of three testing points. The air-conditioning parameters studied were: coefficient of performance COP, system capacity q e, system heat rejection q c, and compressor power W. Figures 4 through 7 present comparison between experimental and predicted parameters. Figure 4 presents a comparison of simulated and measured coefficient of performance COP. The majority of data points as seen in figure 4 lies within 13% relative error of the calculated coefficient of performance. Analyzing these results, It can be concluded that the model overpredicted the coefficient of performance COP. However, predicted COP values are within reasonable limits. The values obtained for the system capacity prediction are shown in Figure 5. In a majority of cases the system capacity was predicted within a ±10% difference of the measured values. These results are relatively consistent especially if we considered that they were calculated based on airside measurements only.

Predicted and Measured COP 3.5 +/-10% 3 Predicted 2.5 2 1.5 1.5 2 2.5 3 3.5 Measured Figure 4.- Predicted and measured coefficients of performance (COP) Predicted and Measured Cooling Capacities 38000 36000 +/- 10% 34000 32000 Predicted (Btu/hr) 30000 28000 26000 24000 22000 20000 18000 18000 20000 22000 24000 26000 28000 30000 32000 34000 36000 38000 Measured (Btu/hr) Figure 5.- Predicted and measured system capacities

Predicted and Measured Heat Rejection 44000 +/-10% 39000 Predicted (Btu/hr) 34000 29000 24000 24000 29000 34000 39000 44000 Measured (Btu/hr) Figure 6.- Predicted and measured system heat rejections Predicted and Measured Compressor Power Input 14000 13000 +/-5% 12000 Predicted (Btu/hr) 11000 10000 9000 8000 8000 9000 10000 11000 12000 13000 14000 Measured (Btu/hr) Figure 7.- Predicted and measured compressor power

Figure 6 presents results of the comparison between the calculated and predicted system heat rejection for the entire set of experimental data. These results have an uncertainty of about ±10%. These comparisons show that the model accurately predicted the system heat rejection. All predicted data points showed good agreement with experimental data. Figure 7 compares predicted and measured compressor powers for our entire set of data. In this case the uncertainty is about ±5%. Three out of nine data points were underpredicted within 10% by the model. This observation may indicate the importance of selecting experimental points for characterization compressor components. This selection should take into account very different compression ratios. Conclusions A simple model for an air conditioner has been developed.. Figures 4 through 7 have shown that the present model predicted parameter results in reasonable agreement with the experimental observations for all conditions tested.. The accuracy of the air-conditioner model is quite satisfactory since used characteristic parameters are determined by using three testing points. This computer model would be valuable to air conditioning manufacturers because system model can be generated quickly by testing few operating points. The present model is easy to use while keeping good accuracy. The ability to select any combination of input indoor and outdoor air conditions increases the value of the model as a design tool. This model will be relevant to manufacturers in the developing countries that have limited experimental and financial resources at their disposal. REFERENCIAS Fischer, S.K., and C.K. Rice., 1983, The Oak Ridge heat pump models. Oak Ridge National Laboratory, ORNL/CON-80/R1. Incropera, F.P., and D.P. DeWitt., 1990, Fundamentals of heat and mass transfer, 3 rd ed. New York: John Wiley & Sons, Inc. Kays, W.M., and A.L. London., 1984, Compact heat exchangers, 3 rd ed. New York: McGraw-Hill. Popovic, P., and H.N.Shapiro., 1995, A Semi-Empirical Method for Modeling a Reciprocating Compressor in Refrigeration Systems. ASHRAE Transactions. Vol 101. Part 2. Pp 367-382. Popovic, P., and H.N. Shapiro., 1998, A modeling study of a centrifugal compressor. ASHRAE Transactions. Vol.104. Part 2. Pp. 121-135. Rabelhl, R.J., J.W. Mitchell, and W.A. Beckman., 1999, Parameter Estimation and The use of Catalog Data in Modeling Heat Exchangers and Coils. International Journal of Heating, Ventilating, Air-Conditioning and Refrigerating Research. Vol 5, No 1, pp. 3-17. Rosario, L., 1999, A Simplified Experimental Model to Simulate an Air Conditioner, Ph.D. Thesis, University of South Florida, Tampa, Florida. Stoecker, W.F., and J.W. Jones., 1982, Refrigeration and Air Conditioning, 2 nd ed. McGraw-Hill, Inc. New York, New York.