Top 10 Circuit Protection Considerations

Similar documents
A series of technology briefs spanning Tyco Electronics product portfolio

SM712 Series 600W Asymmetrical TVS Diode Array

A p p l i c a t i o n N o t e

Power surges can also be generated by equipment in your facility such as:

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

Telecommunication Line Protectors

APPLICATION NOTE. Circuit Protection Considerations for USB Overcurrent Protection

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Technical Article MS-2443

SM Series 400W TVS Diode Array

SDC15. TVS Diode Array for ESD Protection of 12V Data and Power Lines. PROTECTION PRODUCTS Description. Features. Mechanical Characteristics

NUP2105L, SZNUP2105L. Dual Line CAN Bus Protector SOT 23 DUAL BIDIRECTIONAL VOLTAGE SUPPRESSOR 350 W PEAK POWER

TAN-058 Application Note Sept 7, 2006

LC05-6. Dual Low Capacitance TVS Array for Telecom Line-Card Applications. PROTECTION PRODUCTS Description. Features. Mechanical Characteristics

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE

Design Fundamentals Protecting Set Top Boxes from ESD and Cable Discharge Threats

Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications

RClamp0821P. Ultra-Low Capacitance 1-Line ESD protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics

Metal-Oxide Varistors (MOVs) Surface Mount Multilayer Varistors (MLVs) > MLN Series. MLN SurgeArray TM Suppressor. Description

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. Secondary Transient Protection for T1/E1 Line Cards

uclamp3301h Low Voltage μclamp TM for ESD and CDE Protection PRELIMINARY Features

HOW TO SELECT VARISTORS

AN1826 APPLICATION NOTE TRANSIENT PROTECTION SOLUTIONS: Transil diode versus Varistor

Gas Discharge Tubes GTCX36-XXXM-R05 Series

Components that Enhance Video Surveillance Reliability

LC03-6. Low Capacitance TVS for High-Speed Data Interfaces. Features. Description. Mechanical Characteristics. Applications

Three-phase monitoring relay CM-PFE

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

High Voltage Power Supplies for Analytical Instrumentation

Protection ICs Insurance for Electronic Devices

SURGE PROTECTIVE DEVICES

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

AN-6 COMMON MISTAKES IN LIGHTNING PROTECTION OF PHONE LINE INTERFACE CIRCUITS

Bourns Resistive Products

LC03-6R2G. Low Capacitance Surface Mount TVS for High-Speed Data Interfaces. SO-8 LOW CAPACITANCE VOLTAGE SUPPRESSOR 2 kw PEAK POWER 6 VOLTS

Following are definitions for major parameters to consider when selecting a power line polarity protection diode for an automotive application.

RC NETWORKS SALES GUIDE

Transient Overvoltage Protection

RClamp0504P RailClamp Low Capacitance TVS Array

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Report On Surge Protection & Voltage Fluctuation

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Bussmann series Third rail fuse links application guide. Leadership in fusible circuit protection solutions

Power Quality Issues, Impacts, and Mitigation for Industrial Customers

Features. Applications. Truth Table. Close

NUP4106. Low Capacitance Surface Mount TVS for High-Speed Data Interfaces SO 8 LOW CAPACITANCE VOLTAGE SUPPRESSOR 500 WATTS PEAK POWER 3.

DC/DC power modules basics

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

How to design SMPS to Pass Common Mode Lightning Surge Test

Power Quality for Information Technology System

White paper. ABB solutions for switching and protection of low speed wind turbines

This is a preview - click here to buy the full publication TECHNICAL REPORT

Advanced Power Supply Topics

Electrical Safety Tester Verification

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage Regulator SPAU 341 C. Product Guide

µclamp3601p TVS Diode for Proximity Switch Input Protection PROTECTION PRODUCTS - MicroClamp Description Features Mechanical Characteristics

uclamp3301d Low Voltage µclamp TM for ESD and CDE Protection PROTECTION PRODUCTS - MicroClamp TM Description Features Mechanical Characteristics

A full range of monitoring solutions for surge arresters Answers for energy.

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

LC01-6. Low Capacitance TVS for High-Speed Telecommunication Systems. PROTECTION PRODUCTS Description. Features. Applications

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Standards in Marine Power Systems. APEC 2014 Session IS2.1 Power Electronic Standards Roger Dougal University of South Carolina Columbia, SC 29208

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

Guide to the electrical parameter classifications of IEC and IEC safety standards

uclamp0541z Ultra Small μclamp 1-Line ESD Protection

CATALOGUE SURGE PROTECTION LOW VOLTAGE

How to Prevent Power Surges: The Leading Cause of Serial Device Server Failures

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

38 Series - Relay interface modules A

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

POWER AND VOLTAGE RATING

Arc Terminator Active Arc-Resistant Switchgear

CPS Y S K CPS Y S C

RClamp0514M RailClamp Low Capacitance TVS Diode Array PRELIMINARY Features

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

RClamp0502BA. Ultra-Low Capacitance TVS for ESD and CDE Protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics

The standards mentioned in this document

MLCC Voltage Strength

Disturbance Recoder SPCR 8C27. Product Guide

Reliability in Surge Protection. Security Systems.

SECTION 13. Multipliers. Outline of Multiplier Design Process:

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Easy Multifunctional Safe

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Trip circuit supervision relay. Type RXTCS

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

PS323. Precision, Single-Supply SPST Analog Switch. Features. Description. Block Diagram, Pin Configuration, and Truth Table. Applications PS323 PS323

RClamp0522PA RClamp0524PA

How To Test A Sidactor Series For A Power Supply


CAN bus ESD protection diode

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

1 pc Charge Injection, 100 pa Leakage CMOS 5 V/5 V/3 V 4-Channel Multiplexer ADG604

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Bourns Announces New Additions to Product Palette

Transcription:

Top 10 Circuit Protection Considerations (Published February 2013, Konstruktion & Entwicklung magazine, Germany) Selecting the right circuit protection components is essential to designing robust, reliable industrial power conversion equipment. This article, drawing on the experience Littelfuse has accumulated over 85 years, outlines the top 10 overvoltage (OV) and overcurrent (OC) protection considerations for low voltage (<1000V) light industrial applications. System Operating Voltage For low voltage equipment, system voltage varies by application, from the 400VAC European threephase supply to the 3.3VDC system control board. For OV protection, it is generally accepted that the rating of the stand off voltage device must be higher than the peak voltage for AC or the highest DC voltage of the power source, including any temporary or long term testing conditions. Increasing the stand off voltage reduces the number of low level conducting events the device must withstand, which will increase life expectancy but may also increase the peak let through voltage or protection voltage, depending on the selected device. For fuse and PPTC selection, the protection device s voltage rating must be higher than the system voltage including any temporary conditions. Interrupting Rating In the circuit protection world, interrupting refers to the interrupting rating of a fuse or circuit breaker (or breaking capacity of a fuse). The chart (right) is taken from a 1A TE type fuse, which is rated at 250VAC; the breaking capacity is at 25A, which means the fuse has the capability to open a 25A current safely at 250VAC. A fuse s interrupting rating must be higher than

the available current from the circuit to be protected (often called the prospective short circuit current). International Standards and Expected Withstand To counter threats like ESD, EFT, and lightning induced surges, some important industry standards have been developed: ESD threat: IEC 61000 4 2 Electrical fast transient: IEC 61000 4 4 Lightning: IEC 61000 4 5 For ESD, the expected withstand is at least 8kV contact. For EFT, the expected withstand is between 1kV and 2kV (industrial). For lightning, the most common expected withstand level s are 6kV and 3kA. Endurance Requirements Compact power conversion equipment components must endure high temperatures and thermal cycling reliably. For low voltage, low power interconnections, the requirement to survive ESD, EFT, or TLP may be up to 20 or 30kV contact discharge for ESD, level 5 or greater for EFT, and 10A+ of TLP. Littelfuse has extended its line of industrial grade parts in the AK Series Diodes up to 15kA 8/20us surge withstanding capability and developed the award winning TMOV25S and TMOV34S devices to help power supply designs pass the relevant regulatory testing. Component Rating vs. Calculated Needs The following illustration of a basic SMPS power structure shows where protection devices like fuses and MOVs/TVS Diodes are used.

1) For surge testing, the fuse must not open due to the OV surge. The rule of thumb: the I 2 t (Melting Integral) of the fuse should be at least five times that of the surge. 2) For OC testing, the fuse should open before other components are affected, start smoking or catch fire. 3) Fuse breaking capacity should be chosen based on short circuit current capability of the power source including any cable/cord. IEC defines three levels (Low, Enhanced and High). 4) Post rectification part (DC Side): Littelfuse has specialty fuses designed for high voltage DC applications using 400VDC to 1000VDC. Lifetime Expectations Designing an industrial power conversion product to last 10 20 years requires considering protection component degradation. For example, lightning induced surges have a quantifiable effect on MOV life. Much the same is true for fuses: in rush current during a switch on sequence can produce OC conditions. MOVs exhibit a power withstanding curve. This graph indicates the number of pulse events a particular MOV can withstand for the pulse duration. This should be considered in conjunction with the electrical environment in which the equipment will be installed.

Temperature derating for OC protection/fuses from 25 C to 85 C: For a WIA (Wire In Air) fuse, derate about 5%. Thin film fuse, derate at 10%. Resettable PPTC, derate at 40%. Pulse cycle withstand for WIA fuses. Stressing a fuse with impulse OC conditions affects the wire element and increased pulse magnitude reduces life.

Voltage Limiting Requirements Control ICs used for industrial power conversion control are smaller, faster and less tolerant of OV and OC, so shorter reaction times and lower protection voltages are essential, especially if the IC has a direct connection to other equipment. Intelligent power control often consists of analog lines, RS communication and/or differential bus communication. Littelfuse has a family of SPA (Silicon Protection Arrays = Diode Arrays) devices tailored for these applications. The two most common ways of diverting OV events to protect sensitive control ICs are crowbar and clamping devices. The crowbar method can be used for wiring of a data port depending upon prevailing operating conditions. The clamping method can be used for both AC and DC power lines, as well as datalines and analog lines. Crowbar Devices (GDT, SIDACtor, and PGB) Clamping Devices (TVS, MOV, and MLV) Long Term and Temporary OV For mains power, select an OV protection device with a rated operating voltage above any potential high mains or long term OV condition to ensure the device is not rendered ineffective by over dissipation. Safety agencies sometimes impose Temporary OV (TOV) testing conditions on equipment; any OV protection device must be able to survive these temporary conditions without risk of fire, etc. TOV conditions can cause catastrophic failure of OV protection devices like varistors due to the longer duration of fault current going through the device. Littelfuse TMOV Series Varistors have an integrated thermal cut out device coupled to the varistor disc for optimal protection against dangerous TOV conditions.

Component Effects on Data Parallel data transmission is giving way to serial data transmission as control ICs become faster and smaller, and data rates have risen sharply. Most of the ICs used now have finer internal geometries, leading to a reduction in OV withstand. Littelfuse was the first supplier to introduce eye diagram measurements for signal integrity checks of ESD protection devices such as PulseGuard for USB 2.0 ESD protection. As a rule of thumb, the 480Mbps data rate of USB 2.0 requires that the capacitance of the protection device be lower than 3.0pF in order to avoid signal integrity problems. The highest capacitance Littelfuse PulseGuard product is 0.12pF; with a leakage current of less than 1nA, it does not disturb such communications. The following table compares the most common ESD protection technologies Littelfuse offers for their suitability for various data rates/interface speeds.

Protection and Testing Today, less circuit design time is available than ever, which can compromise circuit protection. Littelfuse has test labs around the globe to help customers test and debug their boards and applications before applying for official certification. With on site expert guidance, world class test equipment, and circuit protection solution support, Littelfuse truly stands for expertise applied, answers delivered.