Basics of Electricity

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

DIRECT CURRENT GENERATORS

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

Chapter 22: Electric motors and electromagnetic induction

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Introduction to Electricity & Magnetism. Dr Lisa Jardine-Wright Cavendish Laboratory

The generation and supply of electricity within the U.K is achieved through the use of a 3-phase system.

8 Speed control of Induction Machines

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Transformer Calculations

Transformer circuit calculations

Unit 6 Transformers. Lead-in. Basic principles. Task 1. Task 2. What applications of transformers do you know?

Power Quality Paper #3

How To Understand And Understand The Electrical Power System

SYNCHRONOUS MACHINES

1. The diagram below represents magnetic lines of force within a region of space.

AC Generators. Basic Generator

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

Chapter 11. Inductors ISU EE. C.Y. Lee

Principles and Working of DC and AC machines

ElectroMagnetic Induction. AP Physics B

Lab 14: 3-phase alternator.

Line Reactors and AC Drives

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

INDUCTION REGULATOR. Objective:

Three-phase AC circuits

Coupled Inductors. Introducing Coupled Inductors

Eðlisfræði 2, vor 2007

WINDING RESISTANCE TESTING

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Induction Motor Theory

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Drive circuit basics + V. τ e. Industrial Circuits Application Note. Winding resistance and inductance

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.

Science and Reactor Fundamentals Electrical CNSC Technical Training Group. Table of Contents

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011

Chapter 16. Current Transformer Design. Copyright 2004 by Marcel Dekker, Inc. All Rights Reserved.

Presentation of the France Transfo factories

Theory of Heating by Induction

Power Plant Electrical Distribution Systems

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Direct Current Motors

Transformer Design & Design Parameters

USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SUPPLY TO A THREE-PHASE AC FOR CONTROLLING THE SPEED OF A THREE-PHASE INDUCTION MOTOR BY USING A THREE-PHASE TO THREE-PHASE CYCLOCONVERTER

Tamura Closed Loop Hall Effect Current Sensors

Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer

13 ELECTRIC MOTORS Basic Relations

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1

Inductors. AC Theory. Module 3

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

Think About This How do the generators located inside the dam convert the kinetic and potential energy of the water into electric energy?

Equipment: Power Supply, DAI, Universal motor (8254), Electrodynamometer (8960), timing belt.

Objectives. Capacitors 262 CHAPTER 5 ENERGY

THE PER-UNIT SYSTEM. (2) The per-unit values for various components lie within a narrow range regardless of the equipment rating.

Inductors & Inductance. Electronic Components

Basic Load Tap Changer Operation

12. Transformers, Impedance Matching and Maximum Power Transfer

Understanding the Alternator

ES250: Electrical Science. HW7: Energy Storage Elements

Edmund Li. Where is defined as the mutual inductance between and and has the SI units of Henries (H).

COMPUTER AIDED ELECTRICAL DRAWING (CAED) 10EE65

Magnetism Basics. Magnetic Domains: atomic regions of aligned magnetic poles Random Alignment Ferromagnetic Alignment. Net Effect = Zero!

Series and Parallel Circuits

REPORT ON CANDIDATES WORK IN THE CARIBBEAN ADVANCED PROFICIENCY EXAMINATION MAY/JUNE 2008 ELECTRICAL AND ELECTRONIC TECHNOLOGY (TRINIDAD AND TOBAGO)

Current Transformers

How To Understand And Understand The Theory Of Electricity

45. The peak value of an alternating current in a 1500-W device is 5.4 A. What is the rms voltage across?

Last time : energy storage elements capacitor.

Inductance. Motors. Generators

Power Factor Correction for Power Systems First Semester Report Spring Semester 2007

Full representation of the real transformer

Application Note. So You Need to Measure Some Inductors?

Series and Parallel Circuits

Induced voltages and Inductance Faraday s Law

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

EE301 Lesson 14 Reading: , , and

The electrical energy produced at the gen

Direction of Induced Current

EE 221 Circuits II. Chapter 13 Magnetically Coupled Circuits

First Year (Electrical & Electronics Engineering)

DOE FUNDAMENTALS HANDBOOK ELECTRICAL SCIENCE Volume 3 of 4

DEGREE: Bachelor's Degree in Industrial Electronics and Automation COURSE: 1º TERM: 2º WEEKLY PLANNING

STUDY GUIDE: ELECTRICITY AND MAGNETISM

Linear DC Motors Magnetic Flux Permanent Bar Magnets

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

Module 22: Inductance and Magnetic Field Energy

MEASURING INSTRUMENTS. By: Nafees Ahmed, Asstt, Prof, EE Deptt, DIT, Dehradun

Force on Moving Charges in a Magnetic Field

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS

Contactless Power Transfer : Inductive charging of EV

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Lab 8: DC generators: shunt, series, and compounded.

Motors and Generators

Slide 1 / 26. Inductance by Bryan Pflueger

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Power transformers. Special transformers Railway

Transcription:

Basics of Electricity Transformer Theory PJM State & Member Training Dept. PJM 2014 7/11/2013

Objectives At the end of this presentation the Student will be able to: Describe the basic operational theory of transformers Interpret the formula for turns ratio Describe transformer efficiency and losses Describe transformer tap changers Classify the different types of transformers PJM 2014 7/11/2013

Introduction A transformer is a static device that transfers electric energy from one circuit to another magnetically by the process of electromagnetic induction, or mutual induction Principle of electromagnetic induction: An alternating magnetic flux is produced in the magnetic core of the transformer by passing an AC current through the primary winding The magnetic flux circulates in the magnetic core passing through the secondary winding inducing an AC voltage Its function is to change electric system quantities, such as voltage and current, from one level to another

Transformer Theory http://www.ustudy.in/ece/eci/u3

Transformer Theory A transformer is made up of two or more windings wound around a single magnetic core Windings are insulated from each other and from ground except in an autotransformer Primary winding is connected to the power source Secondary winding is connected to the load side Tertiary winding is utilized to provide power to an auxiliary circuit or a reactor

Transformer Theory Magnetic flux is comparable to current through a conductor In electric circuits, the motivating force is electromotive force or emf In magnetic circuits, the motivating force is magnetomotive force or mmf Magnetomotive force and magnetic flux are related to each other by the magnetic property of reluctance Reluctance in a magnetic circuit is similar to resistance in an electrical circuit

Transformer Theory The mmf required to produce the changing magnetic flux is supplied by a changing current through the coil Magnetic flux, current, and mmf are all directly proportional; current is in phase with the magnetic flux wave Current is required to produce a changing magnetic flux which produces an opposing voltage in phase with the applied voltage

Transformer Theory The amount of induced voltage in a transformer depends on: Core composition and shape Number of primary turns Number of secondary turns Primary voltage Relationship between flux and inductance: Increasing current flow increases flux magnitude Increasing turns increases flux concentration Increasing flux concentration increases induction Inductance causes current to lag the voltage by a maximum of 90 o

Transformer Turns Ratio The amount a quantity changes in a transformer is determined by the: Turns Ratio = Transformer Equation: where, V P and V S are the primary and secondary no load voltages N P and N S are the number of turns in the primary and secondary windings

Transformer Turns Ratio Step Up Transformer transfers energy from a low voltage to a high voltage circuit (N S > N P ) A turns ratio of 1/8 (1:8) implies that the secondary coil has eight timesmore turns as the primary coil Step Down Transformer transfers energy from a high voltage to a low voltage circuit (N P > N S ) A turns ratio of 8/1 (8:1) means that the primary coil has eight times more turns than the secondary coil

Transformer Turns Ratio As voltage is stepped up, current is stepped down by the same ratio As voltage is stepped down, current is stepped up by the same ratio Energy is neither created nor destroyed by a transformer Average power (P P ) delivered to the primary coil is equal to the average power (P S ) delivered to the secondary coil

Question #1 A step up transformer has 50 turns in the primary coil and 1250 turns in the secondary coil. The primary current is 10,000 amps and the secondary voltage is 230 kv. Find (a) the primary voltage (b) the secondary current and (c) the average power delivered to the load 50 1 N 1250 25 1: 25 turns ratio NP VP 1 VP a) so so VP N V 25 230 kv S S IS NP IS 1 b) so so IS IP NS 10,000 amps 25 c) PAVG (400 amps)(230,000 volts) 230 kv 25 9200 volts 10,000 amps 25 92 MW 400 amps

Transformer Efficiency/Losses Transformer efficiency is the ratio of the output power to the input power: Most transformers have an efficiency of 97% to 99% Power consumed by a transformer (losses) is caused by: Hysteresis losses (core) Eddy current losses (core) Copper losses (winding)

Transformer Efficiency/Losses Hysteresis loss is due to residual magnetism which remains after the magnetizing force is removed Occurring every half cycle, hysteresis loss is the energy required to reduce the residual magnetism to zero Eddy current flows in the transformer s core and results from the induced voltage in the core caused by the primary winding Voltage is induced in the core and converted to heat Eddy current can be reduced by laminating the core with a higher resistance material

Transformer Efficiency/Losses Copper loss is power dissipated in the transformer windings Copper loss is due to the resistance of the windings Using larger conductors for the transformer windings, which is restricted by the core openings, helps to reduce copper loss

Transformer Taps Tap is a connection at some point on a primary or secondary winding which permits changing the turns ratio which alters the secondary voltage and current No load de energized tap changers Load tap changers Tap changer is motor operated in response to a relay setting to hold voltage at a pre determined level LTC transformers change taps automatically, remote via SCADA, or manually while the transformer is energized

Question #2 An ideal transformer serves a 50 MVA load. The primary voltage is 138 kv and the secondary current is 2174 amps. Find (a) the primary current (b) the secondary voltage and (c) the turns ratio 50 MVA a) I P 362.32 amps 138 kv 50 MVA b) VS 22.999 kv or 23 kv 2174 amps NP VP c) N V S 138 kv 23 kv S 6 1 Turns ratio is 6 :1

Power Transformer Power Transformer is a term given to a transformer used to transfer power for voltages usually higher than 69kV Most power transformers are three phase Power transformers can step up or step down the voltage Other capabilities, such as tap changing equipment can be added to a step up or step down transformer

Autotransformer Autotransformer is a single winding transformer with a terminal dividing the winding into two sections Autotransformers are simply constructed and cost relatively little in comparison

Phase Shifting Transformer Phase Shift Transformer, or phase angle regulator, controls power flow over parallel lines by adjusting the voltage phase angle at one end of the line The interconnection of the windings within the transformer creates the phase shift similar to the operation of power transformers

Phase Shifting Transformer

Distribution Transformer Distribution Transformer is used to reduce voltage to a level which is usable by customers Distribution transformers are mounted on poles, concrete pads, or in underground vaults Operation is similar to power transformers

Question #3 A generating station is producing power that is feeding a 5000 kw resistive load located several miles away. Find (a) the current flow if the power is transmitted at 5 kv (b) the current flow if a 1:46 step up transformer is used to raise the voltage before the power is transmitted; and (c) how many MWs the generator has to produce in each case

Question #3 Answer a)5000 Volts : I P Total Losses 5000 kw 1000 amps 5 kv 2 (1000 amps) (0.5 Ω) 500 kw Total Generation 5500 kw or 5.5 MW b)stepup Transformer V I P New Total Losses (46)(5000 volts) 230 kv 5000 kw 21.7 amps 230 kv 2 (21.7 amps) (0.5 Ω) 236.3 watts Total Generation 5,000,236.3 watts or 5000.236 kw

Lab Volt Exercises Do LabVolt exercises 7.1, 8.1, 9.1 and 9.2

Summary Discussed the basic theories associated with transformer operation Described and applied the formula for calculating transformer turns ratio Examined transformer efficiency and losses Described the operation of transformer tap changers Explained the different types of transformers and their uses

Questions? PJM 2014 7/11/2013

Disclaimer: PJM has made all efforts possible to accurately document all information in this presentation. The information seen here does not supersede the PJM Operating Agreement or the PJM Tariff both of which can be found by accessing: http://www.pjm.com/documents/agreements/pjmagreements.aspx For additional detailed information on any of the topics discussed, please refer to the appropriate PJM manual which can be found by accessing: http://www.pjm.com/documents/manuals.aspx PJM 2014 7/11/2013

Resources and References Rustebakke, H. (1983). Electric Utility Systems and Practices. New York: John Wiley and Sons Miller, R. & Malinowski, J. (1993). Power System Operation. New York: McGraw Hill Inc. PJM 2014 7/11/2013