FLEXTREME AND FLEXTREME IF

Similar documents
TELE-FONIKA CABLE AMERICAS

Flexible cables for submersible products

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

Flygt flexible cables

Communication, Signal & Data Cables

Chlorinated polyethylene ELASLEN TM. Application for Wire and Cable

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.

Hook-Up and Lead Wire

600V Power Cable 600V SOOW SOW

Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5

VIPERFLEX ELECTRIC CABLE

PRODUCT / APPLICATION INFORMATION

Instrumentation Cable Power Cable Assembly Solutions...32

W-2. Stranding Comparison

100% EMI Emission Containment

KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET

CABLE BASICS. Sizing and Selection Standard vs. Custom. Presented by

L O W - S M O K E, Z E R O - H A L O G E N C A B L E S :

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

with coloured cores and overall copper screen UL/CSA... 17

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

Basic Cable Assemblies DELIVERING QUALITY SINCE 1952.

DIRECTCONNECT SERVICE

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND

Design Techniques for High Power RF Coaxial Cable Assemblies

PVC Insulating Tape. Electrical Tapes

All Wires and Cables Are Not Created Equal

RELIABLE AND EFFICIENT MINING MINING CABLES

From manufacturing to distribution, TF Cable is today s premier provider.

Specialty Engineered Materials for Wire & Cable

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Stephanie Watson. Service Life of Electrical Cable and Condition Monitoring Methods

VULCOFAC TAIC-70 O N O . N CAS : N EINECS : Main function :. Crosslinking agent for peroxide cure elastomers

Festoon 715 P PUR cable for flexible application in festoon systems

With over 100 years of conveyor pulley experience, Baldor Dodge can be trusted to keep your conveyors running.

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT Phone: Fax:

The Quality Connection. LEONI Industrial Solutions Custom-Made Cables

Innovative Polymer Solutions for Wire & Cable

INTERNATIONAL STANDARD

Conductix-Wampfler Cables for Reeling Systems

THE STABILOY BRAND ADVANTAGE UNLOCKING THE SECRETS OF ALUMINUM A LOOK AT THE ADVANTAGES OF ALUMINUM ALLOY OVER COPPER

2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com

17 FREE : A New Class of Halogen-Free Cables

CONFLEX ELECTRIC CABLE

MaxCell Technical Manual Design Parameters

Athena is the name given to our assortment of electronic tapes. products of the very highest quality. These tapes both conduct and

A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

UGVCL/SP/591/11KV HT AB CABLE

The proof is here!! Ron Goethals, Philadelphia; June 18, 2014

Building Cables and Wires

How To Cut Downtime And Extend Cable Life. Underground mining cable care and maintenance

Contact Hueson Corporation for additional information or details Sutton Street Northbridge, MA

3M HEAD PROTECTION. For more information, please visit HARD HATS 101 MANUAL

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

Terminal Cleaning and Protection

Nelson MI Cable is a high performance, industrial grade heat tracing cable used for applications requiring:

Simple, Comprehensive Tubing Solutions. Alpha Wire Company

Thomas and Betts Corporation Product Guide Specification

MICRO PLASTICS MOLDED NYLON 6/6 FASTENERS MECHANICAL TEST DATA - UNC - UNF SECTION

Position Cat5e (EMT) Modular Plug Connectors. Application Specification

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

Automotive Wire and Cable Products

SAND CAST CHILL CAST LM4 - TF

Insulation Resistance Testing of Low Voltage Cables in the Field

Cable Installation Notes

Electromotive Systems Flat Festoon and Round Pendant Cable Application Bulletin #: FS-Cable1

Lifeline Fire Protection Cable Systems. Cables

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

Limited Combustible: The New Standard for Fire Safety

Self-Regulating Low Temperature Heating Cable

Exane 125 Drilling Rig and Commercial Marine Cable

Top Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications

Benefits of Thermax N990 in EPDM Compounds

SPECIFICATION RW-2510 Document Number RPS

Key Design Criteria for High Flex Cable Constructions By Mike Levesque, Dale S. Long, and Ron Crouch of C&M Corporation

TECHICAL SPECIFICATION Conductive Elastomer Extruded Gaskets

COMMERCIAL ITEM DESCRIPTION RUBBER, SILICONE

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

Safety & Performance in the Wire and Cable Industry

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

WHITE PAPER Fire & safety performance standards

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

Xtra-Guard Performance Cable

EVA Modification, Wire Coating

Elastomer Library. Material Name Durometer Notes Food Contact Momentive SE Base 35 Used in blend of 6035 & 6075 to provide custom

New Cable Tie Type Classifications

DOW ECOLIBRIUM Bio-Based Plasticizers - Greening of PVC with Renewably Sourced Plasticizers

Roof Systems Overview

2. The mold is closed up and held under hydraulic pressure while the rubber material or compound cures.

Flexible Control Cables

Cable Solutions for Servo and Variable Frequency Drives (VFD)

TECHNICAL SPECIFICATION

4. Cryogenic gloves are generally designed to protect the hands from intense cold or heat.

Thermocouple Wire & Cable

Transcription:

FLEXTREME AND FLEXTREME IF SOOW / SJOOW Flexible Cord TF Cable manufactures a superior industrial cable that offers a high value cosmetic appearance and greater mechanical strength by eliminating design flaws found in all other outdated competitive designs. This paper discusses FLEXTREME and FLEXTREME IF. What is FLEXTREME? A high end product design at no additional cost. Rubber versus Paper and Jute FLEXTREME IF CIRCUIT SIZE CORD COMPETITION FLEXTREME POWER COMPETITION

FLEXTREMECONTROLCABLE COMPETITION LimitationsofPaperandJute HIGHMOISTUREABSORBANCE Juteandpapermaterialsabsorbmoisturewhichdecreases cableperformanceandacceleratescabledeterioration.paperisinferiortorubberfiller material. LIMITEDDURABILITY Juteandpapermaterialshaveinferiormechanicaldurabilitywhich speedsuptheirwearandtearcausedbyrepetitivecablemovementandflexing. TERMINATIONPROBLEMS Messyjacketstrippingduringterminationprocessduetopaperand juteparticles. LESSMECHANICALPROTECTION LowerimpactresistancethanTFCable'sFLEXTREME constructionasrubber filledintersticesprovideimprovedprotectionoversoftpaperandjute material. POORAPPEARANCE FarlessappealingcosmeticappearanceincomparisontoTFCable s FLEXTREMEconstruction.

FLEXTREME IF Interstices Filled with Jacket Compound FLEXTREME Rubber Fillers FLEXTREME Rubber Fillers FLEXTREME and FLEXTREME IF Cable constructions utilizing a manufacturing process that fills the conductor interstices with the same rubber compounds used in the insulation and jacket results in a superior design and higher product performance than paper constructions offered by competition. T jackets (IF).

FLEXTREME Product Family Benefits JACKET TEAR RESISTANCE FLEXTREME integral filled rubber construction offers superior resistance to jacket tear and damage due to bending and flexing occurring in reeling applications. CONDUCTOR SLIP PREVENTION FLEXTREME integrally filled rubber construction prevents conductors from shifting inside and moving during flexing and bending which is a leading cause of conductor corkscrewing and convolutions. IMPROVED APPEARANCE The symmetrical cable core of the FLEXTREME construction greatly improves the overall appearance because the cable is more round and smooth. IMPROVED FLEXING AND MOVEMENT FLEXTREME constructions offer superior performance over paper and jute used by competitors due to more durable material that resists wear and tear during cable operation and movement. TERMINATION EASE The simplified FLEXTREME cable core improves speed of termination and ease of jacket stripping. This is achieved with the use of a separator tape or talc between the cable core and jacket. HIGH CHEMICAL RESISTANCE Specially formulated jacket material provides high resistance to oils, solvents and acids. HIGH WEATHERABILITY PERFORMANCE Cable design allows for high performance under severe heat and cold weather conditions and long term exposure to sunlight. HIGH FLAME RESISTANCE Cable design meets UL s VW 1, CSA s FT2 and MSHA s flame test requirements. INDEPENDENTLY CERTIFIED by UL, CSA, and MSHA. PROLONGED CABLE LIFE All of the above benefits ensure a prolonged cable life.

Insulation and Jacket Compound Overview: In house specially formulated and mixed CPE (Chlorinated Poly Ethylene) and EPR (Ethylene Propylene Rubber) compounds used by TF Cable for insulating and jacketing of conductors, offer superior performance that not only meets but also greatly exceeds mechanical parameter requirements of UL 62 Flexible Cords and Cable standard. Cable EPR Insulation test: acc. to UL 62 Aging temp 110 C/240 hrs in hot air oven Aging temp 121 C/18 hrs in oil Type of test TF Cable unit average result UL 62 required Tensile strength (un-aged samples) MPa 6.8 min: 3.4 Tensile strength (aged samples @110 C/240 hrs in hot air oven) MPa 8.1 Not specified Tensile strength change (un aged vs. aged) % 118 min: 50 Tensile strength (aged samples @121 C/18 hrs in oil) MPa 5.1 Not specified Tensile strength change (un aged vs. aged) % 76 min: 60 Elongation at break (un aged samples) % 370 min: 200 Elongation at break (aged samples @110 C/240 hrs in hot air oven) % 282 Not specified Elongation at break (un aged vs. aged) % 77 min: 50 Elongation at break (aged samples @121 C/18 hrs in oil) % 242.7 Not specified Elongation at break (un aged vs. aged) % 65.8 min: 60 Insulation Test Results Analysis: Analyzing mechanical performance of TF Cable's EPR and CPE compounds we can see that our insulation material on an un aged sample possesses extremely high tensile strength and elongation at break which are double in value in comparison to the minimum requirement specified by UL 62 standard. Even after sample aging in hot oil and air oven for an extended period of time, our EPR insulating compound still shows great performance when tested, greatly exceeding requirements specified by Underwriters Laboratories in their Flexible Cord standard.

Cable CPE Jacket test: acc. to UL 62 Aging temp 110 C/240 hrs in hot air oven Aging temp 121 C/18 hrs in oil Type of test unit TF Cable average result UL 62 required Tensile strength (un-aged samples) Tensile strength (aged samples @110 C/240 hrs in hot air oven) Tensile strength change (un aged vs. aged) Tensile strength (aged samples @121 C/18 hrs in oil) Tensile strength change (un aged vs. aged) Elongation at break (un aged samples) Elongation at break (aged samples @110 C/240 hrs in hot air oven) Elongation at break (un aged vs. aged) Elongation at break (aged samples @121 C/18 hrs in oil) Elongation at break (un aged vs. aged) MPa 12.97 min: 8.3 MPa 14.73 Not specified % 113 min: 50 MPa 12.04 Not specified % 92.8 min: 60 % 376 min: 200 % 254 Not specified % 67 min: 50 % 322 Not specified % 85.6 min: 60 Jacket Test Results Analysis: Un aged samples of our CPE jacketing compound show superior performance when tested for tensile strength and elongation at break, surpassing UL 62 specified values by 56% and 88% respectively. Samples subjected to aging due to hot air and hot oil also demonstrated their excellent mechanical durability by beating UL 62 minimum values by an average of 48% on the tensile strength test and 21% average on the elongation at break test. These high endurance mechanical characteristics ensure superior performance of our cable in the field, providing high resistance to mechanical abuse and resistance to other factors such as heat, temperature and chemicals, leading causes of cable aging and deterioration. EXTREME CONDITIONS CALL FOR FLEXTREME

TF Cable Tele Fonika Cable Americas 555 Remington Blvd. Bolingbrook, IL 60440 630 406 9000 www.tfcable.com