Position Cat5e (EMT) Modular Plug Connectors. Application Specification
|
|
- Frederick Alvin Daniel
- 7 years ago
- Views:
Transcription
1 Application Specification /May/2008 Rev H 8-Position Cat5e (EMT) Modular Plug Connectors NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Figures and illustrations are for identification only and are not drawn to scale. 1. INTRODUCTION This specification covers the requirements for application of Category 5e (EMT) Modular Plug Connectors. These requirements are applicable to hand or automatic machine terminating tools. Cables approved for use with these connectors are round, twisted-pair cables, shielded or unshielded; with AWG stranded conductors. The insulated conductor outside diameters must be between 0,80 and 1,00 mm [.031 and.039] and a cable jacket outside diameter between 4,7 and 7,0 mm [.185 and.275]. See Section 3.2 for cable details. When corresponding with Tyco Electronics Personnel, use the terminology provided in this specification to facilitate your inquiries for information. Basic terms and features of components are provided in Figure 1. Category 5e (EMT) Plug Connector Assembly Boot Shield Antitangle Performance Wire Holder / Load Bar Strain Relief Contact No. 8 Housing Contact No. 1 Figure 1: Basic terms and features 2008 Tyco Electronics AMP España, S.A., Barcelona (Spain) All International Rights Reserved * Trademark Indicates change 1 of 11 LOC IK
2 2. REFERENCE MATERIAL 2.1. Revision Summary This paragraph is reserved for a revision summary of changes and additions made to this specification. The following changes were made for this revision: Replaced and updated Figure 9, 10 and 13. Rewrite paragraph 3.2.C.7 Added pn shields and in table Figure Customer Assistance Reference Base Part Numbers , , , , and are representative numbers of 8-position Category 5e (EMT) Modular Plug Connectors. Use of these numbers will identify the product line and expedite your inquires through a service network established to help you obtain product and tooling information. Such information can be obtained through a local Tyco Electronics Representative (Field Sales Engineer, Field Applications Engineer, etc) Drawings Customer Drawings for specific products are available from the responsible Engineering Department via the service network. The information contained in the Customer Drawings takes priority if there is a conflict with this specification or with any other technical documentation supplied by Tyco Electronics Specifications Product Specification provides test results and product performance requirements Instructional Material The following list includes available instruction sheets (408-series) and customer manuals (409-series) that provide operation, maintenance, and repair of tooling. In addition, follow the instructions and procedures outlined in Paragraph 3.2 of this specification for product assembly procedures. Document Number Document Title Terminating Modules [ ] For Use with Modular Plug Dual Terminators PRO-CRIMPER III Hand Tool and Die [ ] for EMT and Cat6 Mod Plug Connectors PRO-CRIMPER III Hand Crimping Tool Frame Assembly [ ] Modular Plug Dual Terminator [ ] 3. REQUIREMENTS 3.1. Storage A. Ultraviolet Light Prolonged exposure to ultraviolet light may deteriorate the chemical composition used in the connector components. B. Shelf Life All components products should remain in the shipping containers until ready for use to prevent damage. These products should be used on a first in, first out basis to avoid storage contamination. C. Chemical Exposure Do not store connector components near any chemicals listed below, as they may cause stress corrosion cracking in the product. Alkalies Ammonia Citrates Phosphates Citrates Sulfur Compounds Amines Carbonates Nitrites Sulfur Nitrites Tartrates NOTE Where the above environmental conditions exist, phosphor-bronze contacts are recommended if available. Rev H 2 of 11
3 3.2. Cable A. Cable Specifications 1. Cable Type: Round jacketed, Shielded or Unshielded, 4, 2 or 1 Twisted Pairs (Pairs individually shielded or not) 2. Conductor Type: Stranded conductor, AWG, 7-strands. 3. Conductor Insulation Outside Diameter: mm [ in.] for any one conductor. 4. Cable Jacket Insulation Diameter: 4,7-7,0 mm. [ in.]. 5. Shield Type: Foil with drain wire and/or braid, with or without drain wire. 6. Cable Pair Arrangement: The arrangement of colour-coded pairs within the cable jacket applicable to TIA/EIA T568B wiring and the termination procedures described in this specification is shown in Figure 2. Cable end A applies to one end of the cable and cable end B to the opposite end. For TIA/EIA T568A wiring or termination of cables with pair arrangements other than shown in Figure 2, contact the responsible Tyco Electronics Engineering Department. Cable Filler (Optional) Cable Filler (Optional) Figure 2 B. Cable Preparation (Figure 3) 1. Slide each boot over the relevant end of the cable before the cable stripping operation. 2. Strip the cable jacket [ ] as shown. CAUTION Do not nick the insulation of the conductors or the shield of the cable (if present) 3. If the cable is shielded, fold the outside shield and drain wire (if present) back over the jacket. In case of overall braid and foil together, foil must be trimmed up to 2.0 [.079] max from the jacket end. Individual pair shields must be trimmed up to 2.0 [.079] max from the jacket end. 4. If present, cut and remove any cable filler, ripcord or plastic wrap. 5. Slide the plug shield over the cable jacket and cable shield. CAUTION Do not tear the cable shield. Do not slide the plug shield past the folded-back end of the cable shield Rev H 3 of 11
4 1. Slide the boot 2. Strip the cable jacket, recommended length mm [ ] 2 mm 3. Fold the outside shield back over the jacket, In case of braid and foil together, foil must be trimmed up to 2 mm max. 4. Foil of individual pair shields must be trimmed up to max 2mm max. C. Cable Positioning 5. Slide the plug shield over the cable jacket and cable shield Figure 3: Cable preparation 1. While firmly holding the cable jacket next to the stripped end, untwist the pairs as much as possible as shown in figure 4 Original cable twisting Figure 4 Untwist the pairs as much as possible Rev H 4 of 11
5 2. Position the pairs according to the right Wiring. Try to avoid twisting between pairs as much as possible. See Figure 5. Position the pairs (according to Wiring B in this case) Figure 5 3. While firmly holding the positioned pairs, make a preliminary cut to the pairs to help the insertion of the conductors into the wire holder. See Figure 6. Hold firmly the positioned pairs Make a preliminary cut Conductors are ready for insertion Figure 6 Rev H 5 of 11
6 4. Insert the conductors through the wire holder and slide it up to the end. See Figure 7. Insert the conductors through the wire Slide the wire holder up to the jacket end holder Figure 7 5. While holding all conductors down against the wire holder in a flat layer, trim all conductors evenly and square with appropriate tooling, just beyond the front edge of the wire holder as shown in fig. 8. Trim all conductors evenly and Conductors perfectly aligned at the square with appropriate tooling. wire holder edge Figure 8 6. Insert the front of the wire holder and the ends of the conductors into the cavity of the plug housing. See Figure 9. Insert the front of the wire holder into the plug housing cavity Figure 9 Rev H 6 of 11
7 7. Push the wire holder into the housing, making sure it arrives up to the end. See Figure 10. Push the wire holder into the housing until it latches Figure Visually verify that all conductors are fully inserted into the housing with the ends of the conductors seated against the end of the housing cavity. If not, push the cable into the wire holder and check if the wire holder has latched into both sides of the plug housing. CAUTION Do not rotate the cable relative to the plug and do not allow the wire holder to cock at an angle relative to the plug Connector Termination Refer to Section 5, TOOLING, for appropriate crimp tooling and machines that are compatible with this connector. Proceed as follows: 1. Slide the plug shield over the plug subassembly until it seats against the front edge of recessed area around the outside of the plug housing. See figure 11. Slide the plug shield over the plug subassembly Figure Insert the plug and shield assembly into the appropriate tooling and crimp the connector according to the instruction sheet packaged with the tooling. The shield must be free of bulges, tears and must be uniform after the crimping operation. CAUTION Continue pushing the cable toward the plug during crimping to ensure that the conductors remain seated against the front of the housing cavity. Rev H 7 of 11
8 3. The shield end must be against the raised edge of the housing. The strain relief end must be held firmly in place on the cable. See Figure 12. Figure Trim away any braid/foil and drain wire left extending beyond the end of the plug shield. See Figure 13. Once the connector is crimped, trim away any braid/foil left Figure Slide the boot over the crimped plug and shield. See Figure 14. Slide the boot over the crimped plug Figure 14 Rev H 8 of 11
9 3.3. Connector Termination Requirements Figure 15 shows a cutaway of a typical terminated plug and the required location of the conductors. A visual check through the plastic housing of the plug should reveal whether the conductors are within the acceptable range. For optimum transmission performance, it is preferred that all conductors be fully inserted into the plug housing with the ends of the conductors bottomed against the end of the housing cavity. For reliable electrical termination, the conductors must at least be inserted past the contact and into the 0.80 [.032] reference zone. Proper crimp height can be inspected using an indicator with needle-point probes or equivalent. The crimp height shall be measured at the front of the contact as shown in Figure 15. Figure 15: Connector Termination Requirements In addition make sure that maximum gap between shield and housing is less than indicated in Figure Repair/Replacement Figure 16: Connector Termination Requirements Damaged components must not be used. If a damaged component is evident, it must be replaced with a new one. 4. QUALIFICATIONS The Modular Plug Connectors are not required to be Listed or Recognized by Underwriters Laboratories Inc. (UL), or Certified to the Canadian Standards Association (CSA). Rev H 9 of 11
10 5. TOOLING This section provides a selection of tools for termination of the modular plugs. Hand tools are designed for a prototype applications, field terminations, and low volume production. Automatic machines are designed for high productivity cable assembly terminations. Refer to Figure 17 for available termination tooling (and instructional material). Dual Terminator Machine ( ) (Power Supply AC Adapter) (Power Supply DC Output) Dual Terminating Module [ ] PRO CRIMPER III Hand Tool Assembly [ ] Die Set [ ] Frame Assembly (with Screws) (without Screws) ( ) CAT5E (EMT) AND CAT6 PLUG CONNECTOR THAT ACCEPTS CABLE O.D. 4,7-5,3 [ ] (with shield x) 5,0-6,0 [ ] (with shield x) 5,0-6,0 [ ] (with shield x) 6,0-7,0 [ ] (with shield x) HAND TOOL (DOCUMENT) PRO-CRIMPER III HAND TOOL ASSEMBLY DIE SET ONLY DUAL TERMINATOR (DOCUMENT) TERMINATING MODULE DUAL TERMINATOR ( ) ( ) [ ] ( ) ( ) [ ] ( ) ( ) [ ] ( ) ( ) [ ] Figure 17: Tooling Rev H 10 of 11
11 6. VISUAL AID Figure 18 shows typical applications of Modular Plug Connectors. These illustrations should be used by production personnel to ensure a correctly applied product. Applications which DO NOT appear correct should be inspected using the information in the preceding pages of this specification and in the instructional material shipped with the product or tooling. Figure 18: Visual Aid Rev H 11 of 11
Application Specification SIAMEZE * Standard and 114-13166 Fine Range Terminals 18 Mar 11 Rev C
Application Specification SIAMEZE * Standard and 4-66 Fine Range Terminals 8 Mar Rev C NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters
More informationAMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
More informationFigure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4
This specification covers the requirements for application of ELCON Drawer Series Connectors: True Hot Plug, Blind Mating Mixed Signal and Power Connectors. These connectors are designed for use in pluggable
More information1mm Flexible Printed Circuit (FPC) Connectors
ApplicationType 114-1072 Specification PRE: YM Lee 29 Oct 10 Rev F APP: SF Leong DCR No. D20101029031638_635573 1mm Flexible Printed Circuit (FPC) Connectors NOTE All numerical values are in metric units
More informationHGS620 Shielded Outlet Termination Instructions
Instruction Sheet 860524180 Issue 5, January 2013 SYSTIMAX Solutions HGS620 Shielded Outlet Termination Instructions General These instructions provide the recommended termination procedure for SYSTIMAX
More informationApplication Specification Dual In- Line Memory Module 114-13087 (DIMM) Sockets- DDR2 Solder Tail 05 APR 11 Rev D
Application Specification Dual In- Line Memory Module 114-13087 (DIMM) Sockets- DDR2 Solder Tail 05 APR 11 Rev D NOTE i All numerical values are in metric units [with U.S. customary units in brackets].
More informationStandards Affecting a Premise T-1 Installation
Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity
More informationCat7/Class F New Installation Concept New infrastructure. Handbook
Cat7/Class F New Installation Concept New infrastructure Handbook contents 1 Introduction 3 2 What is the Cat7/Class F installation concept 3 3 Distribution centre 3 3.1 Patch Modules 3 4 How to handle
More informationUser s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01)
User s Manual BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01) BNC Termination Kit Instructions This document is a compilation of Extron s instructions, together with
More informationHT-0095 Mini PV Receptacles 22-32 AWG Crimping Hand Tool. Tool P/N HT-0095
HT-0095 Mini PV Receptacles 22-32 AWG Crimping Hand Tool Tool P/N HT-0095 FCI MANUAL P/N 415988-001 Issued: Date (03/12/99) Page 1 of 18 HT-0095 Issued: Date (03/12/99) Page 2 of 18 Introduction Table
More informationReasons for reissue are in Section 6, REVISION SUMMARY.
Figure 1 This instruction sheet covers the application of OPTIMATE FSMA Fiber Optic Connector Types 905 and 906 for data and telecommunications applications. Base part numbers which apply to each type
More informationAppendix A lists known cable and connector vendors, part numbers and contact information for sourcing.
Recommended CAT5/5E (RJ45) Cable Assemblies For Use With Lantronix Device Servers Overview: This application note provides information for making CAT5/5E (RJ45) cable assemblies to facilitate good communications
More informationAMP CO Plus Insert for Cat. 6 A Applications
Product Specification 108-93039 10/Mar/2011 Rev F AMP CO Plus Insert for Cat. 6 A Applications 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP* CO Plus
More informationCopper Patch Cords. Impact On Network Performance and Reliability
Copper Patch Cords Impact On Network Performance and Reliability 1 The Impact of Copper Patch Cords on Network Performance and Reliability As network infrastructures continue to have a higher impact on
More informationHARAX circular connector
Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor
More informationRutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.
Rutenbeck Network Connection Box Cat. 5, shielded 1-gang, 1 x 8-pole Order No.: 0180 00 2-gang, 2 x 8-pole Order No.: 0178 00 1-gang, (especially for channel construction) Order No.: 0802 00 2-gang, (especially
More informationJack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes
BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can
More informationCategory 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.
Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s
More informationUniversal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00
More informationReasons for reissue are provided in Section 6, REVISION SUMMARY.
Reasons for reissue are provided in Section 6, REVISION SUMMARY. The FRONT OF TOOL has the AMP marking on the link. The BACK OF TOOL (Wire Side), into which the wire is inserted, has the wire size marked
More informationDUBOX TM LOOSE PIECE HAND TOOL
DUBOX TM LOOSE PIECE HAND TOOL Hand Tool Part Number HT-2234 22-30 AWG For termination Of Dubox TM 76357-x01LF Terminals FCI MANUAL P/N 10123594-9090 Issued: Date (12/20/2012) Page 1 of 9 HT-2234 HAND
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationBalun Bulletin- CCTV Systems- Termination
Balun Bulletin- CCTV Systems- Termination Baluns- CCTV Types 1 Balanced Cables: Category Cables 2 Balanced Cables: V/Cat 3 Connecting Balanced Lines 4 Unbalanced Cables: Coax 5 Connecting Unbalanced Lines
More informationI NTERFACE CABLE ADAPTER MODULE
I NTERFACE CABLE ADAPTER MODULE The Interface Cable Adapter Module (ICAM) has two basic uses. First, it enables you to run shielded cable between the industrial sensor interface module (SIM) and the weather
More informationDell P Series Monitor VESA Mounting Bracket Installation Instructions
Dell P Series Monitor VESA Mounting Bracket Installation Instructions The VESA mounting bracket enables a Wyse cloud client to be mounted to the Dell P Series Monitor and the Dell E24 Monitor. The cloud
More informationSECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
More informationThe Quality Connection. High Performance Cable Solutions for the World of Semiconductors
The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying
More informationThe Quality Connection. High Performance Cable Solutions for the World of Semiconductors
The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying
More informationSimpler all over. Simpler all round. fully Ether. PoE+ shielded. MHz. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug
Simpler all over. Simpler all round. fully 10 GB 500
More informationInstallation & Weatherproofing Guide for ENCOM Broadband Radios
Installation & Weatherproofing Guide for ENCOM Broadband Radios Read the following instructions before proceeding with your ENCOM Wireless Radio installation. Keep these instructions in safe location for
More informationWIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS
CONDUCTORS Conductors are needed to complete the path for electrical current to flow from the power source to the working devices and back to the power source. Special wiring is needed for battery cables
More informationUnarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
More informationTermination Procedure for No. 12 Series Soldertacts Contacts for Coaxial Cable: D-602-16, D-602-17
Page: 1 of 12 Termination Procedure for No. 12 Series Soldertacts Contacts for Coaxial Cable: D-602-16, D-602-17 1. Scope 1.1 This standard contains the termination procedure, inspection requirements,
More informationAssembly Instruction CAI- Connector with universal Endbell
CANNON STANDARD Seite 1 von 17 CAI- Connector with universal Endbell Shell size 10 to 36 with APK contact / Trident T2P - contact Illustration and assembly exemplary of CAI Layout 20-0306 with APK / Trident
More informationMYTHBUSTING Takes on Shielded Cabling
MYTHBUSTING Takes on Shielded Cabling Herb Congdon Brian Davis Objectives Take on myths of shielded cabling and use modern-day science to show what's real and what's fiction - through trial and error actually
More information3M Scotchcast Mine and Portable Cable Splice Kit 8096-4
3M Scotchcast Mine and Portable Cable Splice Kit 8096-4 Installation Instructions 1.0 Kit Contents: 2 Funnels 3 EPDM Rubber Cold Shrink Cold Shrink Insulator 1 Wrap-around Mold Assemblies 2 Rubber Mold
More informationETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
More informationPDI-P10LCD Pre-Tensioned Swivel Cartridge
Technical Bulletin PDI-P10LCD Pre-Tensioned Swivel Cartridge Communication Systems, Inc. 40 Greenwood Lane Springboro, Ohio 45066 PH: 937-743-6010 FX: 937-743-5664 http://www.pdiarm.com Replacement Instructions
More information4RU High Density Shelf Installation Instructions
4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...
More informationFIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)
FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) 21T, Rev.4 6-13 IMPORTANT: Before proceeding, retrieve the GLASS SHADE INSTALLATION GUIDE, which is included with the pendant cord set
More informationWiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house
Multimedia Wiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house BY BRIaN walo voice & DATA video AuDIO Because I m an electrician, the
More information6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
More information6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
More informationDepending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.
ASSEMBLY 1 - EPS V2 POWER UNIT (SOLUTION 5) 1.1 - POSITIONING INSIDE THE SEAT TUBE WITH ELASTIC SUPPORT IN THE SEAT BRACKET TUBE Depending on which elastic support you have you can secure the V2 power
More informationSchneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0
Schneider Automation Modbus Plus Network Installing Clustered Node Devices 3000939 00 Version.0 Modbus Plus devices must be installed as specified in a network layout plan, showing each device s mounting
More informationLocoNet, the Digitrax Difference
LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on
More informationReplacing the Gateway M320 Keyboard
Replacing the Gateway M320 Keyboard This package includes a replacement keyboard for your Gateway M320 notebook and these printed instructions. Tools you need You need a small Phillips and a small flat-blade
More informationIntelliChlor Flow-Temperature Switch Replacement Kit Installation Guide
IntelliChlor Flow-Temperature Switch Replacement Kit Installation Guide Technical Support Sanford, North Carolina (8 A.M. to 5 P.M.) Moorpark, California (8 A.M. to 5 P.M.) Phone: (800) 831-7133 Fax: (800)
More informationAMP Standard Terminals and Splices. RoHS. Ready
AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control
More informationHAND CRIMP TOOL Specification Sheet Order No. 63819-0900
HAND CRIMP TOOL Specification Sheet Order No. 63819-0900 FEATURES TYPE 4D Œ A full cycle ratcheting hand tool ensures complete crimps Œ Ergonomic soft grip handles for comfortable crimping Œ A precision
More informationPatch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies
Patch Cords / Cable / Cable Assemblies Premise Connectivity Systems Patch Cords/Cable/ Cable Assemblies w w w. s i g n a m a x. c o m Category 6A 10G Patch Cords C1 Patch Panels and Cross- Category 6 Patch
More informationSealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
More informationCOAXICON Contacts. RF Coax Connectors. Product Facts
COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable
More informationT A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
More informationAndersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationTwo Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts
Product Specification 108-19346 17 APR 2013 Rev F Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts 1. SCOPE 1.1. Content NOTE The product may not perform according
More informationUSER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)
USER MANUAL MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) An ISO-9001 Certified Company Part #07M460-E Doc. #019021UE Revised 02/23/00 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)
More informationATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
More informationCP2 Buried Cable Pedestal Initial & Rehab Installation Instructions
Printing 3 March 2008 CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions This instruction is intended for CP2 cable pedestal installations and replacements. The following tools will be
More informationNEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide
NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series en Quick Install Guide NEI-30 VEI-30 Dinion Infrared Imager Table of Contents en 3 Table of Contents 1 Planning 4 1.1 Hardware Requirements 4 1.2 Pre-installation
More informationInstallation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: 121312 PN: 883884-35L Rev. A
Installation Guide Wyse D Class 4-GB RAM Upgrade Option Kit Products: D90D7, D90DW Issue: 121312 PN: 883884-35L Rev. A Copyright Notices 2012, Wyse Technology Inc. All rights reserved. This manual and
More informationBIX Termination Blocks
Characteristics One piece unit that passes the connection through Unit is reversed after cable connection for the cross-connect field Mounting Frames are available 250-pair, in 50-pair, 300-pair and 900-pair
More informationMDU SC Connector Termination Procedure
MDU SC Connector Termination Procedure Series: 718-NANN-NNNNN B Update the stripping length 11/24/09 A Initial Release 4/30/09 Version Revision History Summary Issue Date I INTRODUCTION This document describes
More informationINSTALLATION PROCEDURES FOR PRINTED CIRCUIT BOARD TERMINATORS D-607-XX
Page: 1 of 9 INSTALLATION PROCEDURES FOR PRINTED CIRCUIT BOARD TERMINATORS D-607-XX 1. SCOPE This engineering standard contains the termination procedures and inspection requirements for the printed circuit
More informationBill Conkling July 2012
Bill Conkling July 2012 Introduction: For any ham, there are moments that are priceless, like snagging that elusive rare DX station on a deserted island that hasn t been activated in 52 years. And certainly,
More information- power windows - alarm system - electric door mirror control - door warning light - central locking - seat memory
Door Wiring Harness Plug Connections Binder -, Electrics Vehicle Type: (86) Model Year: 7 (V) Concern: Door wiring harness plug connections X11 / X12. Information: The rubber boot for the door connector
More informationIndustrial circular connectors
Industrial circular connectors M 16 M 58 010 CONINVERS - M16 to M58 circular connectors for industrial applications CONINVERS GmbH, an independent company, is the specialist for M16 to M58 circular connectors
More informationApplication Tooling Specification Sheet
Extractor Tool Application Tooling Specification Sheet Order No. 63813-1400 FEATURES This tool is designed for the removal of various kinds of crimped terminals from their housings. See below. SCOPE Products:
More informationDirectory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
More informationSimpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug
Simpler all over. Simpler all round. No special tools required for field ASSEMBLY Cat.6 A 10 GB ether. 500 MHz fully shielded Poe+ Data Voice MFP8 Cat.6 A Field assembly RJ45 plug Less fuss. More flexibility.
More informationKSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES
KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES KSR-SK-DB The following installation procedures are suggested guidelines for the installation of in-line cable splices. They
More information1394 locking cables. Your locking cables for AVT IEEE 1394 cameras
Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal
More informationMechoNet TM Network Interface (MNI) Specification Submittal
MechoNet TM Network Interface (MNI) Specification Submittal Models MechoNet Network Interface: MNI RJ (RJ45 Motor Ports): Stock No.: IMNI 0001 TP AS (US version) Stock No.: IMNI 0004 TP AS (UK version)
More informationGENUINE PARTS INSTALLATION INSTRUCTIONS
GENUINE PARTS INSTALLATION INSTRUCTIONS DESCRIPTION: Illuminated Kick Plate APPLICATION: Rogue (2011) PART NUMBER: 999G6 GX010 KIT CONTENTS: Item A B C G H QTY 1 1 1 D 1 E 1 F 3 15 6 Description Kick Plate,
More informationIgnition Coil Sealing Instructions Revision 1.0
Ignition Coil Sealing Instructions Revision 1.0 Parts Required (available at your local auto parts store): - Dielectric Grease - High Temp RTV Silicone - Waterproof crimp on terminals. 0.250" female, sealed,
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationCategory 6 UTP - Cabling System
AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP
More informationVideo Camera Installation Guide
Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide
More informationContact Information: 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.
Technical Data Sheet & Installation Instructions for 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance Bulletin CL-II Contact Information: Parker
More informationOverview - Circular size 16
Overview - Circular size 16 UTP UTG UTO Full plastic circular connector with rugged plastic bayonet coupling system Contact arrangements: 10 (3 to 48) Intermateable with UTO / UTG IP65 (waterprotected
More informationUltra-Fast Fully Insulated FASTON* Receptacle Terminals
Product Specification 108-2043 11Mar11 Rev D Ultra-Fast Fully Insulated FASTON* Receptacle Terminals 1. SCOPE 1.1. Content This specification covers the perform ance requirem ents for Ultra-Fast fully
More informationService Guide. Gateway M275
Service Guide Gateway M275 Contents Replacing Gateway M275 Components.................................... 1 Identifying the convertible tablet PC model...................................... 2 Identifying
More informationTBM5, TBM5-S and TBM5-SV
TBM5, TBM5-S and TBM5-SV Compression Tool Instructions Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Table of Contents 1.0 Operating
More informationTERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246
TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246 OPERATION AND SERVICE INSTRUCTIONS AMPHENOL 157 SERIES TELE-PIERCE MULTI-WIRE TERMINATION TOOL 356-246 AMPHENOL TERMINATION SYSTEMS 1830
More informationInstallation instructions for Series NRX INCOM communications adapter module
4000 NRX RF DRAWOUT SUBTITLE IMAGE (12/15/2010) Effective July 2015 Supersedes October 2010 IL01301033EH04 Installation instructions for Series NRX INCOM communications adapter module Instructions apply
More informationLIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
More informationSmall Form- Factor Pluggable (SFP) DWDM
Small Form- Factor Pluggable (SFP) DWDM Application Specification (Dense Wavelength Division Multiplexer) 114-13178 Connector and Cage Assembly 02 MAY 11 Rev F NOTE i All numerical values are in metric
More informationReplacement Instructions. Warning: During this procedure, keep small parts away from children.
apple ibook G4 Memory Card Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note: Written
More informationR&Mfreenet Advanced Cat 6 A Unshielded Connection Module
R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More information14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
More informationHigh PoE Midspans NPD-6001A NPD-9501A. en Installation Manual
High PoE Midspans NPD-6001A NPD-9501A en Installation Manual High PoE Midspans Table of Contents en 3 Table of contents 1 Safety 4 1.1 About this Manual 4 1.2 Legal Information 4 1.3 Safety Precautions
More informationASKING FOR ASSISTANCE
ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM - 5:00 PM Monday - Friday, Pacific Time Write To: Gefen LLC c/o Customer
More informationSerial Data Grade Cables
VGA INPUT MONITOR OUT VGA INPUT MONITOR OUT 3.5mm STEREO MINI 3.5mm STEREO MINI L R Audio L R Audio AUDIO INPUTS + - + - AUDIO INPUTS + - + - AMPLIFIED OUTPUT 4/8 ohm COM 70V 100V AMPLIFIED OUTPUT 4/8
More informationTECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
More informationTrapezoidal-Connectors Series TMC
Trapezoidal-Connectors Series TMC Subminiature-D Connectors to DIN 41 652/IEC 807-3 General Series TMC connectors are available in 5 different housing sizes with 9, 15, 25, 37 and 50 pins. In applications
More informationAcceptability of Printed Circuit Board Assemblies
Section No.: 12I.2.3, Sheet 1 of 9 Rev Level: 16 Additional Distribution: PCB Assembly Subcontractors 1.0 Purpose 2.0 Scope Acceptability of Printed Circuit Board Assemblies 1.1 The purpose of this standard
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief
More information