Position Cat5e (EMT) Modular Plug Connectors. Application Specification

Size: px
Start display at page:

Download "114-22008. 8-Position Cat5e (EMT) Modular Plug Connectors. Application Specification"

Transcription

1 Application Specification /May/2008 Rev H 8-Position Cat5e (EMT) Modular Plug Connectors NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Figures and illustrations are for identification only and are not drawn to scale. 1. INTRODUCTION This specification covers the requirements for application of Category 5e (EMT) Modular Plug Connectors. These requirements are applicable to hand or automatic machine terminating tools. Cables approved for use with these connectors are round, twisted-pair cables, shielded or unshielded; with AWG stranded conductors. The insulated conductor outside diameters must be between 0,80 and 1,00 mm [.031 and.039] and a cable jacket outside diameter between 4,7 and 7,0 mm [.185 and.275]. See Section 3.2 for cable details. When corresponding with Tyco Electronics Personnel, use the terminology provided in this specification to facilitate your inquiries for information. Basic terms and features of components are provided in Figure 1. Category 5e (EMT) Plug Connector Assembly Boot Shield Antitangle Performance Wire Holder / Load Bar Strain Relief Contact No. 8 Housing Contact No. 1 Figure 1: Basic terms and features 2008 Tyco Electronics AMP España, S.A., Barcelona (Spain) All International Rights Reserved * Trademark Indicates change 1 of 11 LOC IK

2 2. REFERENCE MATERIAL 2.1. Revision Summary This paragraph is reserved for a revision summary of changes and additions made to this specification. The following changes were made for this revision: Replaced and updated Figure 9, 10 and 13. Rewrite paragraph 3.2.C.7 Added pn shields and in table Figure Customer Assistance Reference Base Part Numbers , , , , and are representative numbers of 8-position Category 5e (EMT) Modular Plug Connectors. Use of these numbers will identify the product line and expedite your inquires through a service network established to help you obtain product and tooling information. Such information can be obtained through a local Tyco Electronics Representative (Field Sales Engineer, Field Applications Engineer, etc) Drawings Customer Drawings for specific products are available from the responsible Engineering Department via the service network. The information contained in the Customer Drawings takes priority if there is a conflict with this specification or with any other technical documentation supplied by Tyco Electronics Specifications Product Specification provides test results and product performance requirements Instructional Material The following list includes available instruction sheets (408-series) and customer manuals (409-series) that provide operation, maintenance, and repair of tooling. In addition, follow the instructions and procedures outlined in Paragraph 3.2 of this specification for product assembly procedures. Document Number Document Title Terminating Modules [ ] For Use with Modular Plug Dual Terminators PRO-CRIMPER III Hand Tool and Die [ ] for EMT and Cat6 Mod Plug Connectors PRO-CRIMPER III Hand Crimping Tool Frame Assembly [ ] Modular Plug Dual Terminator [ ] 3. REQUIREMENTS 3.1. Storage A. Ultraviolet Light Prolonged exposure to ultraviolet light may deteriorate the chemical composition used in the connector components. B. Shelf Life All components products should remain in the shipping containers until ready for use to prevent damage. These products should be used on a first in, first out basis to avoid storage contamination. C. Chemical Exposure Do not store connector components near any chemicals listed below, as they may cause stress corrosion cracking in the product. Alkalies Ammonia Citrates Phosphates Citrates Sulfur Compounds Amines Carbonates Nitrites Sulfur Nitrites Tartrates NOTE Where the above environmental conditions exist, phosphor-bronze contacts are recommended if available. Rev H 2 of 11

3 3.2. Cable A. Cable Specifications 1. Cable Type: Round jacketed, Shielded or Unshielded, 4, 2 or 1 Twisted Pairs (Pairs individually shielded or not) 2. Conductor Type: Stranded conductor, AWG, 7-strands. 3. Conductor Insulation Outside Diameter: mm [ in.] for any one conductor. 4. Cable Jacket Insulation Diameter: 4,7-7,0 mm. [ in.]. 5. Shield Type: Foil with drain wire and/or braid, with or without drain wire. 6. Cable Pair Arrangement: The arrangement of colour-coded pairs within the cable jacket applicable to TIA/EIA T568B wiring and the termination procedures described in this specification is shown in Figure 2. Cable end A applies to one end of the cable and cable end B to the opposite end. For TIA/EIA T568A wiring or termination of cables with pair arrangements other than shown in Figure 2, contact the responsible Tyco Electronics Engineering Department. Cable Filler (Optional) Cable Filler (Optional) Figure 2 B. Cable Preparation (Figure 3) 1. Slide each boot over the relevant end of the cable before the cable stripping operation. 2. Strip the cable jacket [ ] as shown. CAUTION Do not nick the insulation of the conductors or the shield of the cable (if present) 3. If the cable is shielded, fold the outside shield and drain wire (if present) back over the jacket. In case of overall braid and foil together, foil must be trimmed up to 2.0 [.079] max from the jacket end. Individual pair shields must be trimmed up to 2.0 [.079] max from the jacket end. 4. If present, cut and remove any cable filler, ripcord or plastic wrap. 5. Slide the plug shield over the cable jacket and cable shield. CAUTION Do not tear the cable shield. Do not slide the plug shield past the folded-back end of the cable shield Rev H 3 of 11

4 1. Slide the boot 2. Strip the cable jacket, recommended length mm [ ] 2 mm 3. Fold the outside shield back over the jacket, In case of braid and foil together, foil must be trimmed up to 2 mm max. 4. Foil of individual pair shields must be trimmed up to max 2mm max. C. Cable Positioning 5. Slide the plug shield over the cable jacket and cable shield Figure 3: Cable preparation 1. While firmly holding the cable jacket next to the stripped end, untwist the pairs as much as possible as shown in figure 4 Original cable twisting Figure 4 Untwist the pairs as much as possible Rev H 4 of 11

5 2. Position the pairs according to the right Wiring. Try to avoid twisting between pairs as much as possible. See Figure 5. Position the pairs (according to Wiring B in this case) Figure 5 3. While firmly holding the positioned pairs, make a preliminary cut to the pairs to help the insertion of the conductors into the wire holder. See Figure 6. Hold firmly the positioned pairs Make a preliminary cut Conductors are ready for insertion Figure 6 Rev H 5 of 11

6 4. Insert the conductors through the wire holder and slide it up to the end. See Figure 7. Insert the conductors through the wire Slide the wire holder up to the jacket end holder Figure 7 5. While holding all conductors down against the wire holder in a flat layer, trim all conductors evenly and square with appropriate tooling, just beyond the front edge of the wire holder as shown in fig. 8. Trim all conductors evenly and Conductors perfectly aligned at the square with appropriate tooling. wire holder edge Figure 8 6. Insert the front of the wire holder and the ends of the conductors into the cavity of the plug housing. See Figure 9. Insert the front of the wire holder into the plug housing cavity Figure 9 Rev H 6 of 11

7 7. Push the wire holder into the housing, making sure it arrives up to the end. See Figure 10. Push the wire holder into the housing until it latches Figure Visually verify that all conductors are fully inserted into the housing with the ends of the conductors seated against the end of the housing cavity. If not, push the cable into the wire holder and check if the wire holder has latched into both sides of the plug housing. CAUTION Do not rotate the cable relative to the plug and do not allow the wire holder to cock at an angle relative to the plug Connector Termination Refer to Section 5, TOOLING, for appropriate crimp tooling and machines that are compatible with this connector. Proceed as follows: 1. Slide the plug shield over the plug subassembly until it seats against the front edge of recessed area around the outside of the plug housing. See figure 11. Slide the plug shield over the plug subassembly Figure Insert the plug and shield assembly into the appropriate tooling and crimp the connector according to the instruction sheet packaged with the tooling. The shield must be free of bulges, tears and must be uniform after the crimping operation. CAUTION Continue pushing the cable toward the plug during crimping to ensure that the conductors remain seated against the front of the housing cavity. Rev H 7 of 11

8 3. The shield end must be against the raised edge of the housing. The strain relief end must be held firmly in place on the cable. See Figure 12. Figure Trim away any braid/foil and drain wire left extending beyond the end of the plug shield. See Figure 13. Once the connector is crimped, trim away any braid/foil left Figure Slide the boot over the crimped plug and shield. See Figure 14. Slide the boot over the crimped plug Figure 14 Rev H 8 of 11

9 3.3. Connector Termination Requirements Figure 15 shows a cutaway of a typical terminated plug and the required location of the conductors. A visual check through the plastic housing of the plug should reveal whether the conductors are within the acceptable range. For optimum transmission performance, it is preferred that all conductors be fully inserted into the plug housing with the ends of the conductors bottomed against the end of the housing cavity. For reliable electrical termination, the conductors must at least be inserted past the contact and into the 0.80 [.032] reference zone. Proper crimp height can be inspected using an indicator with needle-point probes or equivalent. The crimp height shall be measured at the front of the contact as shown in Figure 15. Figure 15: Connector Termination Requirements In addition make sure that maximum gap between shield and housing is less than indicated in Figure Repair/Replacement Figure 16: Connector Termination Requirements Damaged components must not be used. If a damaged component is evident, it must be replaced with a new one. 4. QUALIFICATIONS The Modular Plug Connectors are not required to be Listed or Recognized by Underwriters Laboratories Inc. (UL), or Certified to the Canadian Standards Association (CSA). Rev H 9 of 11

10 5. TOOLING This section provides a selection of tools for termination of the modular plugs. Hand tools are designed for a prototype applications, field terminations, and low volume production. Automatic machines are designed for high productivity cable assembly terminations. Refer to Figure 17 for available termination tooling (and instructional material). Dual Terminator Machine ( ) (Power Supply AC Adapter) (Power Supply DC Output) Dual Terminating Module [ ] PRO CRIMPER III Hand Tool Assembly [ ] Die Set [ ] Frame Assembly (with Screws) (without Screws) ( ) CAT5E (EMT) AND CAT6 PLUG CONNECTOR THAT ACCEPTS CABLE O.D. 4,7-5,3 [ ] (with shield x) 5,0-6,0 [ ] (with shield x) 5,0-6,0 [ ] (with shield x) 6,0-7,0 [ ] (with shield x) HAND TOOL (DOCUMENT) PRO-CRIMPER III HAND TOOL ASSEMBLY DIE SET ONLY DUAL TERMINATOR (DOCUMENT) TERMINATING MODULE DUAL TERMINATOR ( ) ( ) [ ] ( ) ( ) [ ] ( ) ( ) [ ] ( ) ( ) [ ] Figure 17: Tooling Rev H 10 of 11

11 6. VISUAL AID Figure 18 shows typical applications of Modular Plug Connectors. These illustrations should be used by production personnel to ensure a correctly applied product. Applications which DO NOT appear correct should be inspected using the information in the preceding pages of this specification and in the instructional material shipped with the product or tooling. Figure 18: Visual Aid Rev H 11 of 11

Application Specification SIAMEZE * Standard and 114-13166 Fine Range Terminals 18 Mar 11 Rev C

Application Specification SIAMEZE * Standard and 114-13166 Fine Range Terminals 18 Mar 11 Rev C Application Specification SIAMEZE * Standard and 4-66 Fine Range Terminals 8 Mar Rev C NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4 This specification covers the requirements for application of ELCON Drawer Series Connectors: True Hot Plug, Blind Mating Mixed Signal and Power Connectors. These connectors are designed for use in pluggable

More information

1mm Flexible Printed Circuit (FPC) Connectors

1mm Flexible Printed Circuit (FPC) Connectors ApplicationType 114-1072 Specification PRE: YM Lee 29 Oct 10 Rev F APP: SF Leong DCR No. D20101029031638_635573 1mm Flexible Printed Circuit (FPC) Connectors NOTE All numerical values are in metric units

More information

HGS620 Shielded Outlet Termination Instructions

HGS620 Shielded Outlet Termination Instructions Instruction Sheet 860524180 Issue 5, January 2013 SYSTIMAX Solutions HGS620 Shielded Outlet Termination Instructions General These instructions provide the recommended termination procedure for SYSTIMAX

More information

Application Specification Dual In- Line Memory Module 114-13087 (DIMM) Sockets- DDR2 Solder Tail 05 APR 11 Rev D

Application Specification Dual In- Line Memory Module 114-13087 (DIMM) Sockets- DDR2 Solder Tail 05 APR 11 Rev D Application Specification Dual In- Line Memory Module 114-13087 (DIMM) Sockets- DDR2 Solder Tail 05 APR 11 Rev D NOTE i All numerical values are in metric units [with U.S. customary units in brackets].

More information

Standards Affecting a Premise T-1 Installation

Standards Affecting a Premise T-1 Installation Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity

More information

Cat7/Class F New Installation Concept New infrastructure. Handbook

Cat7/Class F New Installation Concept New infrastructure. Handbook Cat7/Class F New Installation Concept New infrastructure Handbook contents 1 Introduction 3 2 What is the Cat7/Class F installation concept 3 3 Distribution centre 3 3.1 Patch Modules 3 4 How to handle

More information

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01)

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01) User s Manual BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01) BNC Termination Kit Instructions This document is a compilation of Extron s instructions, together with

More information

HT-0095 Mini PV Receptacles 22-32 AWG Crimping Hand Tool. Tool P/N HT-0095

HT-0095 Mini PV Receptacles 22-32 AWG Crimping Hand Tool. Tool P/N HT-0095 HT-0095 Mini PV Receptacles 22-32 AWG Crimping Hand Tool Tool P/N HT-0095 FCI MANUAL P/N 415988-001 Issued: Date (03/12/99) Page 1 of 18 HT-0095 Issued: Date (03/12/99) Page 2 of 18 Introduction Table

More information

Reasons for reissue are in Section 6, REVISION SUMMARY.

Reasons for reissue are in Section 6, REVISION SUMMARY. Figure 1 This instruction sheet covers the application of OPTIMATE FSMA Fiber Optic Connector Types 905 and 906 for data and telecommunications applications. Base part numbers which apply to each type

More information

Appendix A lists known cable and connector vendors, part numbers and contact information for sourcing.

Appendix A lists known cable and connector vendors, part numbers and contact information for sourcing. Recommended CAT5/5E (RJ45) Cable Assemblies For Use With Lantronix Device Servers Overview: This application note provides information for making CAT5/5E (RJ45) cable assemblies to facilitate good communications

More information

AMP CO Plus Insert for Cat. 6 A Applications

AMP CO Plus Insert for Cat. 6 A Applications Product Specification 108-93039 10/Mar/2011 Rev F AMP CO Plus Insert for Cat. 6 A Applications 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP* CO Plus

More information

Copper Patch Cords. Impact On Network Performance and Reliability

Copper Patch Cords. Impact On Network Performance and Reliability Copper Patch Cords Impact On Network Performance and Reliability 1 The Impact of Copper Patch Cords on Network Performance and Reliability As network infrastructures continue to have a higher impact on

More information

HARAX circular connector

HARAX circular connector Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor

More information

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions. Rutenbeck Network Connection Box Cat. 5, shielded 1-gang, 1 x 8-pole Order No.: 0180 00 2-gang, 2 x 8-pole Order No.: 0178 00 1-gang, (especially for channel construction) Order No.: 0802 00 2-gang, (especially

More information

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can

More information

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4. Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

Reasons for reissue are provided in Section 6, REVISION SUMMARY.

Reasons for reissue are provided in Section 6, REVISION SUMMARY. Reasons for reissue are provided in Section 6, REVISION SUMMARY. The FRONT OF TOOL has the AMP marking on the link. The BACK OF TOOL (Wire Side), into which the wire is inserted, has the wire size marked

More information

DUBOX TM LOOSE PIECE HAND TOOL

DUBOX TM LOOSE PIECE HAND TOOL DUBOX TM LOOSE PIECE HAND TOOL Hand Tool Part Number HT-2234 22-30 AWG For termination Of Dubox TM 76357-x01LF Terminals FCI MANUAL P/N 10123594-9090 Issued: Date (12/20/2012) Page 1 of 9 HT-2234 HAND

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Balun Bulletin- CCTV Systems- Termination

Balun Bulletin- CCTV Systems- Termination Balun Bulletin- CCTV Systems- Termination Baluns- CCTV Types 1 Balanced Cables: Category Cables 2 Balanced Cables: V/Cat 3 Connecting Balanced Lines 4 Unbalanced Cables: Coax 5 Connecting Unbalanced Lines

More information

I NTERFACE CABLE ADAPTER MODULE

I NTERFACE CABLE ADAPTER MODULE I NTERFACE CABLE ADAPTER MODULE The Interface Cable Adapter Module (ICAM) has two basic uses. First, it enables you to run shielded cable between the industrial sensor interface module (SIM) and the weather

More information

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Dell P Series Monitor VESA Mounting Bracket Installation Instructions Dell P Series Monitor VESA Mounting Bracket Installation Instructions The VESA mounting bracket enables a Wyse cloud client to be mounted to the Dell P Series Monitor and the Dell E24 Monitor. The cloud

More information

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop

More information

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying

More information

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying

More information

Installation & Weatherproofing Guide for ENCOM Broadband Radios

Installation & Weatherproofing Guide for ENCOM Broadband Radios Installation & Weatherproofing Guide for ENCOM Broadband Radios Read the following instructions before proceeding with your ENCOM Wireless Radio installation. Keep these instructions in safe location for

More information

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS CONDUCTORS Conductors are needed to complete the path for electrical current to flow from the power source to the working devices and back to the power source. Special wiring is needed for battery cables

More information

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored

More information

Termination Procedure for No. 12 Series Soldertacts Contacts for Coaxial Cable: D-602-16, D-602-17

Termination Procedure for No. 12 Series Soldertacts Contacts for Coaxial Cable: D-602-16, D-602-17 Page: 1 of 12 Termination Procedure for No. 12 Series Soldertacts Contacts for Coaxial Cable: D-602-16, D-602-17 1. Scope 1.1 This standard contains the termination procedure, inspection requirements,

More information

Assembly Instruction CAI- Connector with universal Endbell

Assembly Instruction CAI- Connector with universal Endbell CANNON STANDARD Seite 1 von 17 CAI- Connector with universal Endbell Shell size 10 to 36 with APK contact / Trident T2P - contact Illustration and assembly exemplary of CAI Layout 20-0306 with APK / Trident

More information

MYTHBUSTING Takes on Shielded Cabling

MYTHBUSTING Takes on Shielded Cabling MYTHBUSTING Takes on Shielded Cabling Herb Congdon Brian Davis Objectives Take on myths of shielded cabling and use modern-day science to show what's real and what's fiction - through trial and error actually

More information

3M Scotchcast Mine and Portable Cable Splice Kit 8096-4

3M Scotchcast Mine and Portable Cable Splice Kit 8096-4 3M Scotchcast Mine and Portable Cable Splice Kit 8096-4 Installation Instructions 1.0 Kit Contents: 2 Funnels 3 EPDM Rubber Cold Shrink Cold Shrink Insulator 1 Wrap-around Mold Assemblies 2 Rubber Mold

More information

ETHERLINE Ethernet Cable, Connectors & Tools

ETHERLINE Ethernet Cable, Connectors & Tools Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary

More information

PDI-P10LCD Pre-Tensioned Swivel Cartridge

PDI-P10LCD Pre-Tensioned Swivel Cartridge Technical Bulletin PDI-P10LCD Pre-Tensioned Swivel Cartridge Communication Systems, Inc. 40 Greenwood Lane Springboro, Ohio 45066 PH: 937-743-6010 FX: 937-743-5664 http://www.pdiarm.com Replacement Instructions

More information

4RU High Density Shelf Installation Instructions

4RU High Density Shelf Installation Instructions 4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...

More information

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) 21T, Rev.4 6-13 IMPORTANT: Before proceeding, retrieve the GLASS SHADE INSTALLATION GUIDE, which is included with the pendant cord set

More information

Wiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house

Wiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house Multimedia Wiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house BY BRIaN walo voice & DATA video AuDIO Because I m an electrician, the

More information

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),

More information

6000 Series Buccaneer

6000 Series Buccaneer Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available

More information

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27. ASSEMBLY 1 - EPS V2 POWER UNIT (SOLUTION 5) 1.1 - POSITIONING INSIDE THE SEAT TUBE WITH ELASTIC SUPPORT IN THE SEAT BRACKET TUBE Depending on which elastic support you have you can secure the V2 power

More information

Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0

Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0 Schneider Automation Modbus Plus Network Installing Clustered Node Devices 3000939 00 Version.0 Modbus Plus devices must be installed as specified in a network layout plan, showing each device s mounting

More information

LocoNet, the Digitrax Difference

LocoNet, the Digitrax Difference LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on

More information

Replacing the Gateway M320 Keyboard

Replacing the Gateway M320 Keyboard Replacing the Gateway M320 Keyboard This package includes a replacement keyboard for your Gateway M320 notebook and these printed instructions. Tools you need You need a small Phillips and a small flat-blade

More information

IntelliChlor Flow-Temperature Switch Replacement Kit Installation Guide

IntelliChlor Flow-Temperature Switch Replacement Kit Installation Guide IntelliChlor Flow-Temperature Switch Replacement Kit Installation Guide Technical Support Sanford, North Carolina (8 A.M. to 5 P.M.) Moorpark, California (8 A.M. to 5 P.M.) Phone: (800) 831-7133 Fax: (800)

More information

AMP Standard Terminals and Splices. RoHS. Ready

AMP Standard Terminals and Splices. RoHS. Ready AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control

More information

HAND CRIMP TOOL Specification Sheet Order No. 63819-0900

HAND CRIMP TOOL Specification Sheet Order No. 63819-0900 HAND CRIMP TOOL Specification Sheet Order No. 63819-0900 FEATURES TYPE 4D ΠA full cycle ratcheting hand tool ensures complete crimps ΠErgonomic soft grip handles for comfortable crimping ΠA precision

More information

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies Patch Cords / Cable / Cable Assemblies Premise Connectivity Systems Patch Cords/Cable/ Cable Assemblies w w w. s i g n a m a x. c o m Category 6A 10G Patch Cords C1 Patch Panels and Cross- Category 6 Patch

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

COAXICON Contacts. RF Coax Connectors. Product Facts

COAXICON Contacts. RF Coax Connectors. Product Facts COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable

More information

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test

More information

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Andersen Electric Window Opener for Andersen Awning and Roof Windows W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts Product Specification 108-19346 17 APR 2013 Rev F Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts 1. SCOPE 1.1. Content NOTE The product may not perform according

More information

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) USER MANUAL MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) An ISO-9001 Certified Company Part #07M460-E Doc. #019021UE Revised 02/23/00 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions Printing 3 March 2008 CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions This instruction is intended for CP2 cable pedestal installations and replacements. The following tools will be

More information

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series en Quick Install Guide NEI-30 VEI-30 Dinion Infrared Imager Table of Contents en 3 Table of Contents 1 Planning 4 1.1 Hardware Requirements 4 1.2 Pre-installation

More information

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: 121312 PN: 883884-35L Rev. A

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: 121312 PN: 883884-35L Rev. A Installation Guide Wyse D Class 4-GB RAM Upgrade Option Kit Products: D90D7, D90DW Issue: 121312 PN: 883884-35L Rev. A Copyright Notices 2012, Wyse Technology Inc. All rights reserved. This manual and

More information

BIX Termination Blocks

BIX Termination Blocks Characteristics One piece unit that passes the connection through Unit is reversed after cable connection for the cross-connect field Mounting Frames are available 250-pair, in 50-pair, 300-pair and 900-pair

More information

MDU SC Connector Termination Procedure

MDU SC Connector Termination Procedure MDU SC Connector Termination Procedure Series: 718-NANN-NNNNN B Update the stripping length 11/24/09 A Initial Release 4/30/09 Version Revision History Summary Issue Date I INTRODUCTION This document describes

More information

INSTALLATION PROCEDURES FOR PRINTED CIRCUIT BOARD TERMINATORS D-607-XX

INSTALLATION PROCEDURES FOR PRINTED CIRCUIT BOARD TERMINATORS D-607-XX Page: 1 of 9 INSTALLATION PROCEDURES FOR PRINTED CIRCUIT BOARD TERMINATORS D-607-XX 1. SCOPE This engineering standard contains the termination procedures and inspection requirements for the printed circuit

More information

Bill Conkling July 2012

Bill Conkling July 2012 Bill Conkling July 2012 Introduction: For any ham, there are moments that are priceless, like snagging that elusive rare DX station on a deserted island that hasn t been activated in 52 years. And certainly,

More information

- power windows - alarm system - electric door mirror control - door warning light - central locking - seat memory

- power windows - alarm system - electric door mirror control - door warning light - central locking - seat memory Door Wiring Harness Plug Connections Binder -, Electrics Vehicle Type: (86) Model Year: 7 (V) Concern: Door wiring harness plug connections X11 / X12. Information: The rubber boot for the door connector

More information

Industrial circular connectors

Industrial circular connectors Industrial circular connectors M 16 M 58 010 CONINVERS - M16 to M58 circular connectors for industrial applications CONINVERS GmbH, an independent company, is the specialist for M16 to M58 circular connectors

More information

Application Tooling Specification Sheet

Application Tooling Specification Sheet Extractor Tool Application Tooling Specification Sheet Order No. 63813-1400 FEATURES This tool is designed for the removal of various kinds of crimped terminals from their housings. See below. SCOPE Products:

More information

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02. Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11

More information

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug Simpler all over. Simpler all round. No special tools required for field ASSEMBLY Cat.6 A 10 GB ether. 500 MHz fully shielded Poe+ Data Voice MFP8 Cat.6 A Field assembly RJ45 plug Less fuss. More flexibility.

More information

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES KSR-SK-DB The following installation procedures are suggested guidelines for the installation of in-line cable splices. They

More information

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal

More information

MechoNet TM Network Interface (MNI) Specification Submittal

MechoNet TM Network Interface (MNI) Specification Submittal MechoNet TM Network Interface (MNI) Specification Submittal Models MechoNet Network Interface: MNI RJ (RJ45 Motor Ports): Stock No.: IMNI 0001 TP AS (US version) Stock No.: IMNI 0004 TP AS (UK version)

More information

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS GENUINE PARTS INSTALLATION INSTRUCTIONS DESCRIPTION: Illuminated Kick Plate APPLICATION: Rogue (2011) PART NUMBER: 999G6 GX010 KIT CONTENTS: Item A B C G H QTY 1 1 1 D 1 E 1 F 3 15 6 Description Kick Plate,

More information

Ignition Coil Sealing Instructions Revision 1.0

Ignition Coil Sealing Instructions Revision 1.0 Ignition Coil Sealing Instructions Revision 1.0 Parts Required (available at your local auto parts store): - Dielectric Grease - High Temp RTV Silicone - Waterproof crimp on terminals. 0.250" female, sealed,

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Category 6 UTP - Cabling System

Category 6 UTP - Cabling System AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP

More information

Video Camera Installation Guide

Video Camera Installation Guide Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide

More information

Contact Information: 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.

Contact Information: 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance. Technical Data Sheet & Installation Instructions for 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance Bulletin CL-II Contact Information: Parker

More information

Overview - Circular size 16

Overview - Circular size 16 Overview - Circular size 16 UTP UTG UTO Full plastic circular connector with rugged plastic bayonet coupling system Contact arrangements: 10 (3 to 48) Intermateable with UTO / UTG IP65 (waterprotected

More information

Ultra-Fast Fully Insulated FASTON* Receptacle Terminals

Ultra-Fast Fully Insulated FASTON* Receptacle Terminals Product Specification 108-2043 11Mar11 Rev D Ultra-Fast Fully Insulated FASTON* Receptacle Terminals 1. SCOPE 1.1. Content This specification covers the perform ance requirem ents for Ultra-Fast fully

More information

Service Guide. Gateway M275

Service Guide. Gateway M275 Service Guide Gateway M275 Contents Replacing Gateway M275 Components.................................... 1 Identifying the convertible tablet PC model...................................... 2 Identifying

More information

TBM5, TBM5-S and TBM5-SV

TBM5, TBM5-S and TBM5-SV TBM5, TBM5-S and TBM5-SV Compression Tool Instructions Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Table of Contents 1.0 Operating

More information

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246 TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246 OPERATION AND SERVICE INSTRUCTIONS AMPHENOL 157 SERIES TELE-PIERCE MULTI-WIRE TERMINATION TOOL 356-246 AMPHENOL TERMINATION SYSTEMS 1830

More information

Installation instructions for Series NRX INCOM communications adapter module

Installation instructions for Series NRX INCOM communications adapter module 4000 NRX RF DRAWOUT SUBTITLE IMAGE (12/15/2010) Effective July 2015 Supersedes October 2010 IL01301033EH04 Installation instructions for Series NRX INCOM communications adapter module Instructions apply

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Small Form- Factor Pluggable (SFP) DWDM

Small Form- Factor Pluggable (SFP) DWDM Small Form- Factor Pluggable (SFP) DWDM Application Specification (Dense Wavelength Division Multiplexer) 114-13178 Connector and Cage Assembly 02 MAY 11 Rev F NOTE i All numerical values are in metric

More information

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Replacement Instructions. Warning: During this procedure, keep small parts away from children. apple ibook G4 Memory Card Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note: Written

More information

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual High PoE Midspans NPD-6001A NPD-9501A en Installation Manual High PoE Midspans Table of Contents en 3 Table of contents 1 Safety 4 1.1 About this Manual 4 1.2 Legal Information 4 1.3 Safety Precautions

More information

ASKING FOR ASSISTANCE

ASKING FOR ASSISTANCE ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM - 5:00 PM Monday - Friday, Pacific Time Write To: Gefen LLC c/o Customer

More information

Serial Data Grade Cables

Serial Data Grade Cables VGA INPUT MONITOR OUT VGA INPUT MONITOR OUT 3.5mm STEREO MINI 3.5mm STEREO MINI L R Audio L R Audio AUDIO INPUTS + - + - AUDIO INPUTS + - + - AMPLIFIED OUTPUT 4/8 ohm COM 70V 100V AMPLIFIED OUTPUT 4/8

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

Trapezoidal-Connectors Series TMC

Trapezoidal-Connectors Series TMC Trapezoidal-Connectors Series TMC Subminiature-D Connectors to DIN 41 652/IEC 807-3 General Series TMC connectors are available in 5 different housing sizes with 9, 15, 25, 37 and 50 pins. In applications

More information

Acceptability of Printed Circuit Board Assemblies

Acceptability of Printed Circuit Board Assemblies Section No.: 12I.2.3, Sheet 1 of 9 Rev Level: 16 Additional Distribution: PCB Assembly Subcontractors 1.0 Purpose 2.0 Scope Acceptability of Printed Circuit Board Assemblies 1.1 The purpose of this standard

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief

More information