Single-phase UPS NeTYS RT from 1100 to VA Complete professional solutions for the protection and availability of IT infrastructures

Similar documents
Phase Modular Finally the benefits of Modular ups are for all

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

PowerGem Pro Uninterruptible Power Supply

4.0 UPS dedicated to ICT for unmatched energy savings

LAP ENERGIA PARA DATACENTERS

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

RIELLO ELETTRONICA. Master HP

CATALOGUE. Single-phase UPS for home, office and critical IT applications

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SNMP Web Management. User s Manual For SNMP Web Card/Box

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

MAJORSINE Power Inverter

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Uninterruptible Power Supply

NeTYS PR VA

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

Online UPS. PowerWalker VFI 1000R/1U

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

UNINTERRUPTIBLE POWER SUPPLY (UPS)

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

Assembled in Florida, USA.

Smart-UPS On-Line 230 V

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Model #: SMART2200CRMXL

Technical Data. back-up time in minutes 100% load % load

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Dell Smart-UPS 1,500 3,000 VA

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

How To Use A Power Supply Unit (Upu)

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Back-UPS Pro 1300/1500 Installation and Operation

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

User s Manual Before using the inverter, you need to read and save the safety instructions.

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

UPS Sentinel DUAL SDL

The UPS for the highest security in industry and data centres

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

PE8216/PE8324. Energy Intelligence Solutions

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR

VISION UPS UPS PRODUCT CATALOGUE

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

Installation and Operation Back-UPS 1250, 1300, 1500

GB USER S MANUAL GB 41

USER MANUAL Online UPS 1K/2K/3K

Multi-Range Programmable DC Power Supplies 9115 Series

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

HCS-3600MB2 Conference Main Unit

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

Eaton 93PM UPS Where aesthetics meet intelligence.

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

TLE Series. Product Description kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

Stroom voor elke toepassing

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Energy Communication Unit (ECU)

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

Electronic Control Devices The European Product Catalogue 2007

Energy Communication Unit (ECU)

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Thyristor-controlled power supplies and battery chargers

User Manual 1K/2K/3K Online UPS

USER MANUAL Online UPS 1K/2K/3K Rack

The Leading KVM Switch Solutions Provider, ATEN. 40-Port KVM Over the NET - 1 local / 4 remote user access

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

BB800 Off-Grid Solar System

Transcription:

from 00 to 000 VA Complete professional solutions for the protection and availability of IT infrastructures Infrastructures such as data centres, networking systems and modern data networks play a leading role in value production on the information market. Power supply problems can result in data loss and undermine the productivity of IT infrastructures. That is why IT loads require an extremely high-quality power supply, without disturbances or interruptions: business continuity is the name of the game. The way in which maintenance is performed on power supply devices is crucial in IT environments: the possibility of unintrusive servicing (performed without switching off the load), reduced maintenance time and load protection are all fundamental considerations. Such infrastructures are increasingly required to manage the high-density processing power of modern servers and devices (including those offered by blade technologies), in terms of space consumption and heat output. A detailed knowledge of the operating parameters of power supply equipment is equally important. This enables breakdowns to be prevented by maintaining the profitability of the infrastructure s operations. RANGES 0 A Your protection for > Switching > Storage > Servers and networking devices > VoIP communication systems > Structured cabling systems > Control systems > Video surveillance systems

from 00 to 000 VA Equipment for professionals has been designed to meet the demands of professional applications. is the most effective high power density solution on the market:. W / cm ( kva / kw module). The space and time-saving tower / rack conversion option means that it can be installed easily either in tower mode or inside standard rack cabinets. The system also offers practical connectivity options by means of IEC0 sockets or terminals. Protection Online double conversion technology guarantees matchless power quality. This ensures a perfectly stable sinusoidal waveform at the output of the, regardless of the quality of the mains supply. It includes built-in backfeed protection, in compliance with the latest system regulations. This feature protects against reverse current flow without the need for additional external devices. Converts from Tower to Rack mounted APPLI 0-0 - 0-00 - 0-0 - 0-0 A Availability The optional external manual bypass module also assures the continuity of power supplied to loads during routine or non-routine maintenance of the system, resulting in reduced mean time to repair (MTTR). With the special manual parallel / bypass module, + redundant architectures are easy to construct using. This type of architecture guarantees maximum power availability in any situation, even following the breakdown of an electronic module, and is therefore essential for mission-critical applications. The possibility of adding extra battery modules (EBM) means that back-up time in battery mode is flexible. This enables the system to meet the need for different back-up times depending on the load supplied, thus providing a tailor-made solution. Additionally in the case of parallel installations, the same battery pack can be used for both power modules, guaranteeing full back-up time availability even if one of the two modules is undergoing maintenance. Comprehensive range The wide range of modules offers an effective power solution architecture to match the high-quality power demands of any medium or small load. This vast range of solutions is accompanied by a series of standard and optional features that fulfil all of the protection, quality and communication needs of the installation environment. The multilingual LCD display provides detailed information about the status and alarms of the applications. features for communication with external devices, such as Ethernet or USB, enable all models to communicate and integrate easily in the infrastructure via the most widespread protocols on the market. can be installed easily in rack or tower mode, or converted from one mode to another at any time, using the standard accessories included with the product. Parallel redundant operation for business continuity To achieve the highest level of availability and to power critical utilities, modules above kva can be configured for : redundancy. Redundant operation (+) means: the system incorporates one more module than is needed to protect the load ; in the event of a breakdown, it guarantees sufficient power supply capacity to the load by maintaining online protection. Parallel technology is based on the principle of load sharing, whereby both units are always kept active. In a redundant configuration, overall system availability is much higher than a conventional system using similar technology. + redundant configuration does not require additional circuits and can therefore be set up at a later date, simply by using two modules and a collector / manual bypass module which simplifies cabling and maintenance of the installation. To further streamline the solution, it is also possible to select between operation with separate battery or shared battery, which is extremely useful in the case of applications requiring high levels of autonomy. Load Load

from 00 to 000 VA The high-performance, versatile and comprehensive system Simple to install IEC input and output connections compatible with most IT equipment. Compact footprint (U / mm) for installation in rack cabinets. Attractive design for visible installation in offices. USB port and HID protocol as standard for direct interfacing with Windows systems, without the need for additional specialist software. Easy to use No configuration necessary on first startup. Wide range of communication protocols (including TCP / IP and SNMP) for integration into LAN networks or building management systems (BMS). Meets practical needs Online double conversion technology with sinusoidal waveform, to completely filter out all disturbances from / to the mains power supply and to ensure maximum protection of the utility. Optional battery extension modules (BEM) to meet all back-up time requirements, even after installation. Clear and uncluttered LED interface, with buzzers that immediately indicate the operating status of the, even for less specialist users. communication equipment USB connection. RS connection for JBUS protocol. HID protocol for interfacing with Windows systems. electrical equipment Built-in backfeed protection. Protection against atmospheric phenomena (NTP) for telephone / ADSL modems. RJ connection for Emergency Power Off (EPO). Connection for battery extension modules. Communication options Programmable dry-contact interface. WEB / SNMP manager interface for connection to LAN network. This accessory can be integrated in the by means of the slot located on the back panel. Electrical options Battery extension modules. netys 0 A

from 00 to 000 VA Battery expansion Connections NRT-U00 NRT-U00 EBM x NRT-B00 Back up time (minutes) 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 netys 0 a + EBM NRT-U00 NRT-U00 NRT-U00 NRT-U00 NRT-U00 NRT-U00 NRT-U00 NRT-U000 NRT-U000 x NRT-B00 x NRT-B00 x NRT-B00 x NRT-B00 x NRT-B00 x NRT-B000 netys 0 a 00 VA 0 + EBM NRT-U000 x NRT-B000 0 % of nominal load % of nominal load 00 % of nominal load Technical data 00 00 00 000 MODELS NRT-U00 NRT-U00 NRT-U00 NRT-U000 POWER 00 VA / 00 W 00 VA / 00 W 00 VA / 00 W 000 VA / 00 W Architecture online double conversion VFI with input PFC and automatic bypass INPUT Voltage 0 V (ph) 0~ Vac ; up to 0 Vac @0 % load Frequency 0 / 0 Hz + /-0% (Auto-Selectable) Power factor / THDi > 0. / < % OUTPUT Voltage (pure sinewave) 0 V (ph) selectable 00 / 0 / 0 / 0V, 0 or 0 Hz +/- % (+/- 0.0 Hz in battery mode) Efficiency up to % online mode Overload capability up to 0 % continuously ; % x min ; 0 % x 0 sec Output connections x IEC 0-C (0 A) x IEC 0-C (0 A) + x IEC 0-C0 ( A) BATTERY autonomy* 0 Voltage Vdc Vdc Vdc Vdc Recharge time < h to recover 0 % capacity COMMUNICATION Mimic panel LED RS (DB port) Jbus protocol USB HID protocol WEB / SNMP (Ethernet RJ port) option option option option COMM slot Dry contacts card option option option option EPO input (RJ port) Modem / ADSL surge protection Parallel port - - - - STANDARDS Performance & topology IEC 00- (VFI-SS-) Safety / EMC IEC 00-- (TÜV-GS certified) IEC 00- Product certifications CE, TÜV-GS, A-Tick, C-Tick ENVIRONMENT Operating ambient temperature from 0 C to +0 C (from C to C for best battery life) Storage temperature range from - C to +0 C (from C to C for best battery life) Relative Humidity 0-0 % non-condensing Noise level (ISO ) < db < db DIMENSIONS & WEIGHT size std BUT (W x D x H mm). x x 0. x 0 x 0. x 0 x 0. x 0 x 0 size RACK U U U U U weight std BUT (kg) EBM module size (W x D x H mm). x x 0. x 0 x 0. x 0 x 0. x 0 x 0 EBM module RACK U U U U U EBM module weight (kg) * @ % of nominal load. netys 0 a 00 VA - 00 VA - 000 VA 0. Mains input socket (IEC 0). Fan. Output socket (full power). Telephone / modem line protection. EPO (Emergency Power Off) input. RS interface (JBUS protocol). USB port. Input protection. Output sockets (IEC 0-0 A) 0. Battery extension connector. Slot for optional communication boards Control panel netys 0 a. Yellow LED lit. Operation in bypass mode. Green LED lit. Mains healthy. OFF button. Green LED lit. Normal operation (inverter in-line). ON / TEST and buzzer override button. LED bar. Depending on the situation, this indicates either the charge level or the capacity of the battery

from 000 to 000 VA The professional system for high power density, high availability and complete integration Simple to install Terminal input and output connections with built-in input protection by means of magnetothermal switch. Compact footprint: U ( mm) for - kva and U ( mm) for - kva, for installation in rack cabinets. Optional manual bypass enables routine maintenace to be performed without disconnecting the powered appliance. Built-in LAN interface for remote monitoring via Web browser or SNMP protocol Easy to use LCD display with menu available in languages Extensive range of communication protocols (including TCP / IP and SNMP) for integration in building management system (BMS) networks. Meets practical needs Online double conversion technology with sinusoidal waveform, to completely filter out all disturbances from / to the mains power supply and to ensure maximum protection of the utility. Modular battery extension (EBM) to meet all back-up time requirements, even after installation. Possibility of + parallel redundant configuration to maximise the availability of critical utilities, even in the event of a module breakdown. communication features 0 / 00 LAN Ethernet connection. WEB / SNMP manager interface for connecting the system to the Ethernet network. RS serial connection with JBUS protocol. electrical equipment Built-in backfeed protection. RJ connection for Emergency Power Off (EPO). Connection for battery extension modules. Port for parallel operation. Communication options Programmable dry-contact interface. netys 00 B 0

from 000 to 000 VA Battery expansion + EBM (standard) + EBM + EBM Technical data 000 000 000 000 MODELS NRT-000K NRT-000K NRT-000K NRT-000K POWER 000 VA / 00 W 000 VA / 00 W 000 VA / 00 W 000 VA / 000 W Architecture online double conversion VFI with input PFC and automatic bypass Parallel redundant function + + + + INPUT Voltage 0 V (ph) ~0 Vac up to 0 Vac @0% load Frequency 0 / 0 Hz + /-0% (Auto-Selectable) Power factor / THDi > 0. / < % OUTPUT Voltage (pure sinewave) 0 V (ph) selectable 00 / 0 / 0 / 0V - 0 or 0 Hz + /- % (+/- 0.0 Hz in battery mode) Efficiency up to % online mode Overload capability up to 0 % continuously ; % x min ; 0 % x 0 sec Output connections terminals BATTERY autonomy* 0 Voltage Vdc Vdc 0 Vdc 0 Vdc Recharge time < h to recover 0 % capacity COMMUNICATION Mimic panel LCD languages RS (DB port) Jbus protocol WEB / SNMP (Ethernet RJ port) COMM slot Dry contacts card option option option option EPO input (RJ port) Parallel port STANDARDS Performance & topology IEC 00- (VFI-SS-) Safety / EMC IEC 00-- (TÜV-GS certified) IEC 00- Product certifications CE, TÜV-GS, A-Tick, C-Tick ENVIRONMENT Operating ambient temperature from 0 C to +0 C (from C to C for best battery life) Storage temperature range from - C to +0 C (from C to C for best battery life) Relative Humidity 0-0 % non-condensing Noise level (ISO ) < db DIMENSIONS & WEIGHT size std BUT (W x D x H mm) (.) x 0 x 0 (.) x 0 x 0 (.) x x 0 (.) x x 0 size RACK U U+U U+U U+U U+U weight std BUT (kg).+0 +0.+ 0+ EBM module size (W x D x H mm). x 0 x 0. x 0 x 0 0. x x 0 0. x x 0 EBM module RACK U U U U U EBM module weight (kg) 0 0 * @ % of nominal load. NRT-000K NRT-000K NRT-000K NRT-000K NRT-000K NRT-000K NRT-000K NRT-000K NRT-000K NRT-000K NRT-000K NRT-000K EBM x NRT-B000 x NRT-B000 x NRT-B000 x NRT-B000 x NRT-B000 x NRT-B000 x NRT-B000 x NRT-B000 0 % of nominal load % of nominal load 00 % of nominal load Back up time (minutes) 0 0 0 0 0 0 0 0 Connections netys 0 a netys 0 a. EPO (Emergency Power Off) input. Fan. Battery extension connector. Output terminals. Input terminals. Input switch. RJ LAN ethernet connector. Parallel port connector. RS interface (JBUS protocol) 0. Slot for optional communication boards. Battery extension connector Control panel netys 00 a 000 VA - 000 VA + battery 000 VA - 000 VA + battery. Yellow LED lit. Operation in bypass mode. Green LED lit. Mains healthy. OFF button. Green LED lit. Normal operation (inverter in-line). ON / Enter and buzzer override button. Navigator buttons. Alphanumeric LCD display Electrical options 0 + parallel module. Manual bypass without interruption. Battery extension modules. 0 dcg_0 VALID FOR FRANCE VALID FOR ITALY ISO 00:00 ISO00:00 FM EMS www.socomec.com Non contractual document. 00, Socomec SA. All rights reserved.