Providing sound advice www.beralarm.ch CH-3250 Lyss
Focuses of our solutions 2
Principle alarm registration BMG External alarms Alarm registration Internal alarms Alarm server ATAS 3
Models Alarm server B700 with two basic equipments Basic equipment ATAS Basic equipment BMG Extension BMG Extension ATAS Extensions for both basic equipments 4
Internal alarms with ATAS to MiVoice Office 400 Alarm server B700 Ready for R4.0 DECT Mitel 61x/62x/63x/650 MiVoice Office 400/IntelliGate ATAS Master AIN MiVoice 53xx/53xxIP Satellit Alarm display on DECT cordless and fixed terminals Connection to communication server via Ethernet Connection alarm server to communication server is controlled From R4.1 SIP Mitel 68xx 5
Basic functions ATAS alarms Alarm has priority to telephone call Fire Direct alarm display Acoustic and optic signalisation Call distinction Fox keys Call repetition Priority handling Escalation handling Stop Ack 6
Certified by Mitel The best investment protection: With certified solutions always the best available technology! 7
Licenses alarming subscribers ATAS Basis 10 subscribers 5 groups 20 subscribers 10 groups 50 subscribers 25 groups 200 subscribers* 50 groups * 100 subscribers/group 8
External alarms with Beralarm Message Gateway Alarm SMS SMSC Swisscom SMS Email BMG Voice High transmission of alarms Several subscribers sumultaneously SMS with status message Connection alarm server to BMG is controlled Voice alarms with text-to-speech function The Beralarm Message Gateway BMG is a portal operated by Beralarm. 9
Operation cost Beralarm Message Gateway Basic module SMS/Email Flat rate per month EUR 12.00 (incl. 50 SMS/month, not cumulative) Further SMS per message EUR 0.20 Email free of cost Additional module voice On request The billing is made quarterly by Beralarm GmbH. 10
Alarm acquisition via Beralarm Message Gateway Alarm acquisition and handling SMS Call BMG Alarms of personal security equipments SMS Alarms of external buildings (pump stations etc.) Alarm activation by SMS Alarm activation by Email Watchdog function Email Alarms from IT infrastructure 11
Multifaceted possibilities of alarm acquisition Alarmserver Contacts Serial LAN KNX EnOcean Temp. C ATAS BMG Technical alarms Fire Emergency buttons etc. Nurse call OPC Fire call system XML Sprinkler Supervisory RS232 RS422/485 ESPA4.4.4 Modbus-TCP Chestonag Decentral signal registration Technical alarms Emergency buttons Window contacts Control of temperature Cooling chambers Medicinal cabinet Red-Key TAE SMS Email Call LINE Printers 12
Hardware alarm server B700 CX1010 from Beckhoff: industrial PC, no moving components, Ethernet 10/100/1000 Mbit/s, 1-second UPS, battery-buffered clock for time and date (batterie exchangeable). 2 separate Ethernet interfaces Joystick Power supply 24 VDC System alarms Serial interface RS232 COM1 Other I/O modules Compact- Flash memory card Static cooling 13
WEB configuration Alarm server Setup Tool (AST) included in basic equipment of alarm server Quick Setup for simple commissioning Alarm list, monitor for serial interface etc. Monthly protocols Timeswitch to switchover day/night 14
From the inhabitant / patient to the nursing staff Retirement home / Hospital www.beralarm.ch
From the inhabitant / patient to the nursing staff Room 215 Nurse call Serial interface ESPA4.4.4 Stop Ack Applications for nurse call systems GETS, Tyco, Bosch NurseCall, Ackermann, Ascom, ER Systems, Televic etc. Applications for dementia systems (run away protection) PreWatch, Bosch NurseCall 16
Function hands-free call into the room Display Room 215 From MiVoice Office 400 R3.0 also possible from terminals Stop Ack Room 235 Mrs. Smith Activation alarm Activation voice connection Nurse is calling into the room Speaker connection from nurse into room Room terminal is automatically switched to hands-free mode From MiVoice Office 400/IntelliGate 7.93 without OIP-Server From MiVoice Office 400 R3.0 SP2: Green button acknowledges alarm 17
Example of typical nursing home for the elderly Alarm Internal ATAS External BMG SMS Day immediately delayed BMG Night immediately delayed Voice Fire alarm Technical alarms Room call Nursing staff with alarms from different wards Fire alarm Technical alarms Alarm server Technical support 18
The other solution: room call with terminals Room 215 Stop Ack System terminal or analogue terminal OpenPhoneCare 14 Activation of alarm with Red Key Programmable on digital or analogue terminals 19
The KNX solution for simple installations Handling of the signals (logic) in alarm server Room 215 Push button (outlet RJ45) KNX sensor with call and presence button Direct connection KNX bus to borne Room 216 Room 217 20
Example and references Alterszentrum Schlossgut, CH-3110 Münsingen Alterssiedlung Kantengut, CH-7000 Chur Bürgerspital, Alterszentrum Falkenstein, CH-4053 Basel Residenz Au Lac, CH-2501 Biel/Bienne Centro Sociosanitario, CH-6675 Cevio Bildungsstätte Sommeri, CH-8580 Sommeri Stiftung Graswinkel, CH-8302 Kloten Connection of different nurse call systems, technical alarms The arguments One equipment - alarm and telephone in one equipment; direct display of alarms fewer ways for the staff; charging bay the hand-over day/night occurs automatically; escalation targeted alarms 21
Threat at work / evacuation Administrative Offices / Schools www.beralarm.ch
Emergency calls in case of threat, for evacuation, paramedics Activation with button or Alarm display at the subscribers of the selected group Emerg call Emerg call Emerg call Emerg call Hotkeys 1: Emergency Call by quick dialling on any terminal and confirmation at the triggering terminal (quiet alarm) Emergency call activated OK 23
Example evacuation of administrative office Activation by quick dialling 119 Alarm Alarm to management team Alarm Alarm Alarm Assembly point According agreement (e.g. conferenc call) within the management team, an evacuation alarm is triggered with 199. Alarm goes to all subscribers of the administrative office. 24
Example medical emergency call in an industrial enterprise MiVoice Office400 Call 144 From MiVoice Office 400 R3.0 Alarm server Alarm Day Night Emergency call center Internal ATAS immediately immediately External BMG delayed delayed Activation by quick dialling 144 First aid team 25
Example emergency call in a school with several sites Activation with Red Key button From MiVoice Office 400 R3.0 SP2 Pre-alarm Quiet alarm on triggering terminal with possitility of reset by red button. 90 Voralarm (Stopp mit roter Taste): Personenalarm SMS Voice Alarm Day Night Internal ATAS Alarms to the appositely building group. The choice of group occurs according to the triggering site (DECT localisation). immediately immediately External BMG delayed delayed 26
Conference call Activation of alarm by quick dialling Alarm and note to green button From MiVoice Office 400 R3.0 also possible from terminals Conference Integration in conference Setup of a conference call using green button Connection of max. 6 subscribers From MiVoice Office 400/IntelliGate 7.93 without OIP-Server 27
Activation of emergency call with EnOcean Cable 2 x 2 x 0.25mm 2 shielded length of bus max. 500m Max. 8 radio anntenna per bus Range within building ca. 30m Triggering by sensors with EnOcean radio technology 28
Example and references Heimstätte Bärau, CH-3552 Bärau Gemeinde und Schulen, CH-6331 Hünenberg Hallenbad Sportgebäude Luzern, CH-6005 Luzern BWS Berufswahlschule, CH-8180 Bülach Zentrum für Gehör und Sprache Zürich, CH-8038 Zürich Gemeindeverwaltung Münsingen, CH-3110 Münsingen Activation emergency call by quick dialling, partly with external alarms The arguments In case of an emergency easy and safe alarms; emergency call quick evacuation to the assembly point; activation of alarms by quick dialling on any terminal; discreet activation also by pressing button 29
Protection of lonely working people Personal security www.beralarm.ch
Personal security with Mitel 632d Emergency button Escape From MiVoice Office 400 R3.1: Hands-free call to alarming person No movement Emergency call Smith > Alarm key pressed Stop Ack Man down Fully compatible terminal Personal security alarm with display of triggering event Battery control and test alarm Continuous tone at the triggering terminal for quick finding of the needy person 31
DECT localisation Alarm server V6.5: Automatic reading of the DECT radio units from communication server Emergency call Smith > alarm key pressed > Production 63% > Storage 52% > Forcourt 22% Stop Ack Localisation of subscribers terminal Display of the three strongest DECT radio units Signal control from alarm server to terminal 32
Personal security with Mitel DT433 ATEX Terminal DECT-ATEX to use in GAP mode With emergency button and man down (activation with Red Key funktion). From MiVoice Office 400 R3.1 Referring to alarms Localisation: display of the actual DECT unit No ATAS alarms possible on this terminal In case of an alarm a recall to this terminal can be installed 33
Personal security summary R3.1 Mitel Mitel Functions / terminal 632d DT433 Emergency button * Man down * No movement * Escape Localisation (display DECT functions) 3 3 1 EX protection DECT terminal GAP ATAS alarms on terminal Voice alarms on terminal BMG BMG * Only 1 common function From MiVoice Office 400 34
Example SBB: Personal security on different sites BMG Voice Control center Personenschutz Personenschutz Alarmserver Alarm vor Ort Personenschutz Alarmserver Alarm vor Ort Personenschutz Alarmserver Alarm vor Ort Personal security Alarm server Alarm on site 35
Example and references Multiple frequency changert and power stations SBB Multiple power stations BKW Carbagas, CH-3428 Wiler b. Utzenstorf ARA Oberglatt, CH-9230 Flawil Zentrum Paul Klee, CH-3006 Bern Kläranlage Obersee, CH-8716 Schmerikon Bigler AG, CH-3294 Büren an der Aare Kläranlage Meilen, CH-8706 Meilen Protection of lonely working people with localisation and surveillance, WEB applications The arguments Comfort - alarm is integrated in communication device; activation of alarm individually adjustable per subscriber; localisation cost-efficient thanks to existent DECT infrastructure 36
From the blockage to the technical service Industry www.beralarm.ch
Solution alarm server with node in AIN Master DECT area 1 Satellite DECT area 2 and alert the subscribers at the master or satellite LAN/WAN Contacts on the alarm server or node trigger an alarm Alarm server Node CH-3250 Lyss www.beralarm.ch Mit Providing Sicherheit sound gut advice beraten 38
Solutions decentral signal registration Alarm server Node Ethernet with contacts, serial interfaces etc. LAN/WAN LWL Optical fiber node Multimode until 2 km Singlemode until 20 km BMG SMS Alarm devices with SMS transmission CH-3250 Lyss www.beralarm.ch Mit Providing Sicherheit sound gut advice beraten 39
Example manufacturing company with 24h production Alarm Internal ATAS External BMG SMS Day Night immediately immediately delayed delayed BMG Voice Alarms production Personal security Alarm server Technical support CH-3250 Lyss www.beralarm.ch Mit Providing Sicherheit sound gut advice beraten 40
Example and references KEBAG Kehrichtbeseitigung und ARA, CH-4528 Zuchwil AVAG KVA AG, CH-3600 Thun ARA Schwyz, CH-6430 Schwyz Bischofberger AG, CH-9057 Weissbad Wagner AG, CH-9104 Waldstatt Feintool International Management AG, CH-3250 Lyss Gysi AG, CH-3018 Bern Kieswerk Oberwangen, CH-3173 Oberwangen Phonak AG, CH-8712 Stäfa Technical alarms, decentral alarm registration, external alarms with mit BMG The arguments Multiple possibilities of registration different kinds of serial interfaces are ascertainable; use of existent structures existent LAN usable for decentral registration CH-3250 Lyss www.beralarm.ch Mit Providing Sicherheit sound gut advice beraten 41
WEB applications Mounting/assembling Support www.beralarm.ch CH-3250 Lyss
WEB applications on PC or touch panel Alarm lists, plans of location for DECT localisation, measuring of temperatures 43
Touch panel colored for WEB applications Sizes 7 and 12, colored Ethernet serial interface 10/100, power supply PoE or 24 VDC For WEB applications 44
Enclosures and racks Your advantage: unpack install connect - READY! Enclosure 400x300x180 mm for wall mounting 19 rack drawer 4 height units for distribution cabinet 45
Remote maintenance VPN Quick access to customer installation Replacement of the hitherto remote maintenace with analog modem 46
Why with us «We are small, flexible, personal and friendly. Beralarm caters to your needs and responds promptly when you call. We always provide helpful and technically relevant information. Because we put our heart and soul into our work.» Martin and Erika Heiz Carmine Carosella Willy Wyttenbach 47
Thank you for your interest in our products. www.beralarm.ch CH-3250 Lyss info@beralarm.ch Tel. +41 32 387 60 90