C e r t i f i c a t e of Conformity
|
|
|
- Ruby Gallagher
- 10 years ago
- Views:
Transcription
1 C e r t i f i c a t e of Conformity No.: /AA/05 Telefication declares that the listed product complies with the Technical standards and specifications as indicated under Annex 2 of this certificate. Product description: Digital Public Address and Emergency Sound System Trademark: See annex 3 Family name: Praesideo Type designation: See annex 3 Serial No: -- Software release No: See annex 3 Manufacturer: Bosch Security Systems B.V. Address: Torenallee 49 City: 5617 BA Eindhoven Country: Netherlands This certificate is granted to: Name: Bosch Security Systems B.V. Address: Torenallee 49 City: 5617 BA Eindhoven Country: Netherlands This certificate has THREE Annexes. Zevenaar, 02 May 2014 W.J.M. Jong Manager Product Certification
2 Annex 1 to Certificate of Conformity 02 May 2014 Number: /AA/05 Annex 1, Page 1 of 2 The validity of this Certificate is limited to products, which are equal to the one examined. Remarks and observations The following conditions are applicable: The tested configuration of the Praesideo system is representative for comparable combinations of components as identified in annex 3 of this certificate. Each component may be installed multiple times into a Praesideo system. The installer is responsible for the correct selection of components and ISO compliance of the completely installed system. ISO compliance of the Praesideo system is only achieved if the installer fulfills all installer specific requirements as stated in the EN AND ISO compliance checklists in the installation and user instructions. Certification of the Praesideo Digital Public Address and Emergency Sound System includes the cabinets (i.e. the enclosed 19" racks) in which the system components are mounted. It is allowed to use one or more cabinets, depending on the size of the Praesideo system. Within the same cabinet family different heights are allowed up to a maximum height that depends on the brand and type of an approved cabinet. The following cabinets have been approved for use with Praesideo: Rittal TS8 series, with lockable glass door, side panels, temperature controlled top fans and having a fixed frame with a maximum height of 42 HU or a lockable swing frame with a maximum height of 40 HU. Only batteries as mentioned in the user manuals of the battery chargers are allowed to be used and must be placed on the ground plane of the cabinet, free from the walls PRAESIDEO Schroff cabinet The power supply system ZDSO400E-AK3 can consist of: main power supply ZDSO-400-E, additional power supply ZDSOR-400-E, additional power supply ZDSOT-400-E, distribution panel PD- 2U-x, battery circuit resistance measurer RMB-1. Implemented optional functions with requirements (per clause of ISO ): 7.2 Alert signal 7.5 Audible warning Silencing of the voice-alarm condition with a manual control Reset of the voice-alarm condition with a manual control 7.10 Output to alarm devices 7.11 Voice-alarm condition output signal Faults related to the transmission path to the emergency detection system Faults related to emergency-loudspeaker zones 11 Manual mode control 11.3 Indication of emergency-loudspeaker zones in the fault-warning condition 12 Interface to external control device(s) 13 Emergency microphone(s) 13.2 Microphone priority 13.3 Microphone emergency-loudspeaker-zone control Redundant power amplifiers The battery mid-point monitor, model SD08 from Alpha Technologies Ltd., may be used with the PRS- 48CH12 battery charger and mounted in the cabinet, but is excluded from certification. The Cobranet Interface is only ISO compliant in combination with the Hirschmann Switch RSR M2M2T1UCCHPHH The Hirschmann Switch may also be used to connect, within the cabinet, other ISO compliant products as listed in annex 3.
3 Annex 1 to Certificate of Conformity 02 May 2014 Number: /AA/05 Annex 1, Page 2 of 2 There are four Praesideo systems possible: * Praesideo 3.5 system based on network controller PRS-NCO-B and PRS-SW software version 3.5x (where x can be 0, 1, 2 or 3) * Praesideo 3.6 system based on network controller PRS-NCO-B and PRS-SW software version 3.6y (where y can be 0 or 1) * Praesideo 4.0 system based on network controller PRS-NCO3 and PRS-SW software version 4.0y (where y can be 0 or 1) * Praesideo 4.1 system based on network controller PRS-NCO3 and PRS-SW software version 4.1
4 Annex 2 to Certificate of Conformity 02 May 2014 Number: /AA/05 Annex 2, Page 1 of 2 Documentation lodged for this Certificate of Conformity Test Reports: - Telefication B.V.: Rev 1.10, 03 September Telefication B.V.: Rev.1.00, 03 September CNPP: , 23 July CNPP: , 17 March VdS GmbH: BMA 11111, 12 January Telefication B.V.: Ver. 1.00, 25 February Telefication B.V.: Rev. 1.00, 10 April 2014 Product Documentation: - Assembly drawings - Bill of materials - Block diagram - Electric diagrams - Photos - User manual - Manufacturer's declarations Technical Standards and Specifications The product shows no non-compliances with: - EN : December, EN /A1: April, EN /A2: January, ISO : July, ISO : August, 2003
5 Annex 2 to Certificate of Conformity 02 May 2014 Number: /AA/05 Annex 2, Page 2 of 2 Technical features and characteristics The product includes the following features and characteristics: Voice Alarm Equipment - 100V loudspeaker outputs
6 Number: /AA/05 Annex 3, Page 1 of 6 The product as described in this Certificate of Conformity includes the following type designations: - Product description: Digital Public Address and Emergency Sound System - Type Designation: Praesideo Software version: 3.5x (where x can be 0,1,2 or 3) - Product description: Digital Public Address and Emergency Sound System - Type Designation: Praesideo Software version: 3.6y (where y can be 0 or 1) - Product description: Digital Public Address and Emergency Sound System - Type Designation: Praesideo Software version: 4.0y (where y can be 0 or 1) - Product description: Digital Public Address and Emergency Sound System - Type Designation: Praesideo Software version: Product description: 48 VDC Battery Charger - Type Designation: PRS-48CH12 - Product description: 48 VDC Battery Charger - Trademark: PSD - Type Designation: PRS-48CHxx-DE (where xx can be 02, 05, 06 or 07) - Product description: Audio Expander - Type Designation: LBB4402/00 - Hardware version: 16/15 - Product description: Basic Amplifier 1 x 500 W - Type Designation: PRS-1B500 - Product description: Basic Amplifier 1 x 500 W - Type Designation: PRS-1B500-EU
7 Number: /AA/05 Annex 3, Page 2 of 6 - Product description: Basic Amplifier 2 x 250 W - Type Designation: PRS-2B250 - Product description: Basic Amplifier 2 x 250 W - Type Designation: PRS-2B250-EU - Product description: Basic Amplifier 4 x 125 W - Type Designation: PRS-4B125 - Product description: Basic Amplifier 4 x 125 W - Type Designation: PRS-4B125-EU - Software version: 3.5x & 3.6y & 4.0y.& Product description: Basic Amplifier 8 x 60 W - Type Designation: PRS-8B060 - Product description: Basic Amplifier 8 x 60 W - Type Designation: PRS-8B060-EU - Product description: Basic Call Station - Type Designation: LBB4430/00 - Hardware version: 06/15 - Product description: Call Stacker - Type Designation: PRS-CRF - Hardware version: 01/10 & 06/10 - Product description: Call Station Interface - Type Designation: PRS-CSI - Hardware version: 01/15 & 01/20 & 01/30
8 Number: /AA/05 Annex 3, Page 3 of 6 - Product description: Call Station Keypad - Type Designation: LBB4432/00 - Hardware version: 01/18 & 01/19 - Product description: Call Station Keypad Module - Type Designation: PRS-CSKPM - Hardware version: 11/00 - Product description: Calll Station Module - Type Designation: PRS-CSM - Hardware version: 11/00 - Product description: Cobranet Interface - Type Designation: LBB4404/00 - Hardware version: 03/10 & 03/15 - Product description: EOL Supervision Board - Type Designation: LBB4443/00 - Hardware version: 01/05 - Product description: Fiber Interface - Type Designation: PRS-FIN - Product description: Fiber Interface Non-Addressable - Type Designation: PRS-FINNA - Product description: Fiber Interface Single-Mode - Type Designation: PRS-FINS - Product description: IP Audio Interface - Type Designation: PRS-1AIP1 - Hardware version: 2.0
9 Number: /AA/05 Annex 3, Page 4 of 6 - Product description: Line Supervision Set - Type Designation: LBB4442/00 - Hardware version: 01/10 - Product description: LSP Supervision Board - Type Designation: LBB4441/00 - Hardware version: 01/05 - Product description: Multichannel Interface - Type Designation: PRS-16MCI - Hardware version: 04/10 & 04/15 - Product description: Network Controller - Type Designation: PRS-NCO3 - Hardware version: 30/00 & 30/10 - Software version: 4.0y & Product description: Network Controller - Type Designation: PRS-NCO-B - Hardware version: 21/05 & 21/08 - Software version: 3.5x & 3.6y - Product description: Network Splitter - Type Designation: PRS-NSP - Product description: Numeric Keypad - Type Designation: PRS-CSNKP - Hardware version: 01/18 - Product description: Power Amplifier 1 x 500 W - Type Designation: PRS-1P500 & 06/10 - Product description: Power Amplifier 1 x 500 W - Type Designation: PRS-1P500-EU - Hardware version: 06/10
10 Number: /AA/05 Annex 3, Page 5 of 6 - Product description: Power Amplifier 2 x 250 W - Type Designation: PRS-2P250 & 06/10 - Product description: Power Amplifier 2 x 250 W - Type Designation: PRS-2P250-EU - Hardware version: 06/10 - Product description: Power Amplifier 4 x 125 W - Type Designation: PRS-4P125 & 06/10 - Product description: Power Amplifier 4 x 125 W - Type Designation: PRS-4P125-EU - Hardware version: 06/10 - Product description: Power Amplifier 8 x 60 W - Type Designation: LBB4428/00 - Hardware version: 04/05 & 05/05 - Product description: Power Amplifier 8 x 60 W - Type Designation: LBB4428/00-EU - Hardware version: 05/05 - Product description: Power supply system with battery backup for Voice Alarm System Praesideo - Trademark: Merawex - Type Designation: ZDSO400E-AK3 - Product description: Praesideo Software - Type Designation: PRS-SW - Software version: 3.5x (where x can be 0,1,2 or 3) - Product description: Praesideo Software - Type Designation: PRS-SW - Software version: 3.6y (where y can be 0 or 1)
11 Number: /AA/05 Annex 3, Page 6 of 6 - Product description: Praesideo Software - Type Designation: PRS-SW - Software version: 4.0y (where y can be 0 or 1) - Product description: Praesideo Software - Type Designation: PRS-SW - Software version: Product description: Remote Call Station - Type Designation: PRS-CSR - Hardware version: 01/15 & 01/20 & 01/30 - Product description: Remote Call Station Module - Type Designation: PRS-CSRM - Hardware version: 11/00 - Product description: SPEC RCS Master - Type Designation: PSP-D Product description: SPEC RCS Slave - Type Designation: PSP-D Product description: Supervision Control Board - Type Designation: LBB4440/00 - Hardware version: 01/05
C e r t i f i c a t e
C e r t i f i c a t e of Continued Compliance Certificate No.: 13229052/AA/02 In compliance with the procedure specified in RD_070, Telefication declares that the stated alarm equipment complies with the
C e r t i f i c a t e
C e r t i f i c a t e of Type-examination No.: 11229072/AA/00 In compliance with the procedure specified in RD_070, Telefication declares that the stated alarm equipment complies with the Technical specifications
Praesideo 3.3. Installation and User Instructions Digital Public Address and Emergency Sound System
Praesideo 3.3 en Installation and User Instructions Digital Public Address and Emergency Sound System Praesideo 3.3 Installation and User Instructions en 2 Praesideo 3.3 Installation and User Instructions
C e r t i f i c a t e
C e r t i f i c a t e of EC Type-examination (Module B) Certificate No.: 10212005/AA/00 Product Category: A.1/5.14; A.1/5.15 With respect to Marine Equipment Directive 96/98/EC and the amending Directive
Plena Voice Alarm System. Software Manual Configuration Software
Plena Voice Alarm System en Software Manual Configuration Software Plena Voice Alarm System Software Manual Table of Contents en 3 Table of Contents Table of Contents...3 1. Introduction...7 1.1 Purpose...7
C e r t i f i c a t e
C e r t i f i c a t e of EC Type-examination (Module B) Certificate No.: 10212004/AA/00 Product Category: A.1/5.14 A.1/5.15 With respect to Marine Equipment Directive 96/98/EC and the amending Directive
Plena Voice Alarm System. Installation and Operation manual
Plena Voice Alarm System. en Installation and Operation manual Plena Voice Alarm System Table of Contents en 3 Table of Contents 1 Safety 9 1.1 Important Safeguards 9 1.2 Important Notices 9 2 About this
PROMATRIX VOICE ALARM SYSTEM. en EN 54-16 devices, supported options and approved firmware versions
PROMATRIX VOICE ALARM SYSTEM en PROMATRIX VOICE ALARM SYSTEM Table of Contents en 3 Table of contents 1 Scope 4 2 Current EN 54-16 devices with supported options 5 3 History 6 3.1 IRIS-Net V2.9.2 6 3.2
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
Praesideo PRS-CSM / PRS-CSRM / PRS-CSKPM Digital Public Address and Emergency Sound System
sch Praesideo PRS-CSM / PRS-CSRM / PRS-CSKPM Digital Public Address and Emergency Sound System en Installation and User Instructions Praesideo PRS-CSM / PRS-CSRM / PRS-CSKPM en 2 Disclaimer Although every
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
Vari-directional Array The smart route to acoustical perfection
Vari-directional Array The smart route to acoustical perfection 2 Vari-directional Array by Bosch The ultimate sound performance for acoustically challenging environments Unmatched sound quality and speech
Praesideo - Digital Public Address and Emergency Sound System
Praesideo - Digital Public Address and Emergency Sound System Praesideo - Digital Public Address and Emergency Sound System 2 Praesideo - Digital Public Address and Emergency Sound System Praesideo - Digital
For more information on the configuration of Praesideo, CobraNet and PC CST check the Praesideo IUI.
APPLICATION NOTE & CobraNet and PC Call Station Introduction This application note (AN) describes an example of the PC Call Station (PC CST) in combination with and CobraNet. General In this example we
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
Installation Handbook. Interactive Fire Alarm System Release 3. Repeater Panel BU-320 / Information Panel BV-320
Interactive Fire Alarm System Release 3 Installation Handbook Repeater Panel BU-320 / Information Panel BV-320 Protecting life, environment and property... P-ASAFE/RI/DE Rev. A, 010531 COPYRIGHT This publication,
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance
TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS 190-535 khz
TOTALLY SOLID STATE NON-DIRECTIONAL RADIO S 190-535 khz This family of radio transmitters has been developed as extremely efficient, highly reliable Non Directional Beacons. ND2000A/4000A» MODULAR CONSTRUCTION»
Control and Indicating Equipment
VdS Guidelines for Fire Detection and Fire Alarm Systems VdS 2540en Control and Indicating Equipment Requirements and Test Methods VdS 2540en : 2010-12 (02) Publishing house: VdS Schadenverhütung GmbH
CB200W Water Leak Detection Panel Application Guide
Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION
Phone System Owner Phone System Engineered by: of Record Drawings: of System Manuals: of Test Reports: System Installer 1. GENERAL INFORMATION Phone Delaware License No: Certificate Holder No. System Supplier
Voice alarm system E100 the new standard for safe evacuation
Voice alarm system E100 the new standard for safe evacuation Clear announcements and future-proof protection in case of fire Answers for infrastructure. E100 from Siemens so everyone knows what to do when
NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)
Safely into a new day Advanced modular FIRE ALARM CONTROL PANEL with additional functionality NJP-400A NJP-401A I m on FIRE (Bruce Springsteen) EN 54-2, EN 54-4 Cert No. 1124a DESCRIPTION OP-400A, NJP-400A,
AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS
Wireless - Emergency Alert Systems Easy installation - Wireless Radio System no wires or wiring required Evacuation, Alert & Lockdown all in one system S.O.S Assist - up to 6 unique SOS assistance zone
SECTION 16721 FIRE ALARM AND DETECTION SYSTEM
1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this
UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-28 33 00.00 40 (February 2014) ----------------------------------- Preparing Activity: NASA Superseding UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS
Emergency voice communications Product Name
Product Name 76 EATON FIRE AND VOICE ALARM SYSTEMS CFCC2556 January 2015 Contents Contents Emergency voice communications Panels Network exchange units 78 Non network exchange units 80 Devices Outstations
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
VM-3000 Series. With new features! Integrated Voice Evacuation System. sound without compromise. www.toa.eu
VM-3000 Series Integrated Voice Evacuation System With new features! sound without compromise www.toa.eu SECURITY WITH CONVICTION Continuously TOA brings the knowledge gained from years of experience in
User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)
User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Edition February 2013 Comments Suggestions Corrections The User Documentation Department would like
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction
Emergency Operating Instructions Fire Alarm S Priority 2 Alarm Fire Alarm Priority 2 Ack Ack How Acknowledge / View Events Press ACK located under flashing indicar. Repeat operation until all events are
HDO700 P FIBRE OPTIC TRANSMITTER
Timo Rantanen 18.1.2011 1(5) HDO700 P FIBRE OPTIC TRANSMITTER HDO700 P is a high performance, extremely linear externally modulated 1550 nm transmitter for HDO fibre optic CATV link. This transmitter type
Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions
Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy
Public Address and Voice Alarm
Training Presentation Public Address and Voice Alarm Slide 1 Contents Introduction What is Voice Alarm? What are the benefits? What standards apply? Intelligibility requirements Issues when designing VA
DS-6 Intercom System Introduction
DS-6 Intercom System Introduction Decentralised communication system for intercom, PA and general alarm according to VDE 0828 and EN 60849 (sound systems for emergency purposes), according to DIN VDE 0833-4
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems
Module 4, Lesson 12 Fire Alarm Systems
Student Manual Module 4, Lesson 12 Fire Alarm Systems Performance Objectives At the conclusion of this lesson, you will be able to: Identify the components and functions of a fire alarm system and determine
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline
Fire Alarm System Plans Review Checklist Property location Date of Review
Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include
Watchdog Monitor user guide
General The Watchdog AW-4, in short AW-4, can be controlled and monitored by a centralized monitor server. This server is located in a large Dutch server centre with high speed connections, directly connected
ALARMS-xx. Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL
Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL User s Guide Version 1.0 07/01/2009 Michael Stevens & Partners Ltd. has made
EN54-16 Voice Alarm System PRODUCT DATASHEETS
EN54-16 Voice Alarm System PRODUCT DATASHEETS WayGuard This page is intentionally left blank Pagina 2 di 16 WayGuard Revision history Rel. Data Autore Modifiche 1.00 25/02/15 First emission Pagina 3 di
IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions
IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions QUICK LINKS Mounting Location Guidelines Open the Sensor Mount the Sensor Sensor Components and Settings Wire the Sensor
MSL1000 Monitored Serial Link Interface Manual V1.01
Audix Systems, Station Road, Wenden, Saffron Walden, Essex, CB11 4LG. Telephone: +44(0)1799 540888 Facsimile: +44(0)1799 541618 www.tycosafetyproducts-europe.com www.audixsystems.co.uk MSL1000 Monitored
User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual
ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) User Manual Table of Contents 1 Introduction 2 General specification 3 Installation 4 Pin assignment & function of connectors 5 Drawing
Firmware Update Notice
Customer Product Information Bulletin PRODUCT : Galaxy Dimension V6.78 No : 041 Date : May 2012 Firmware Update Notice What is the product update? Due to the implementation of the updated EN50131 series
Advanced Intelligent Modules. Overview. Description
Overview Features M200XE Short Circuit Isolator Module M201E Single Output Module M210E Single Input Module M210E CZ Conventional Zone Module M220E Dual Input Module M221E Dual Input Single Output Module
30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
TS510 & TS500. Installation & User Guide. Compatible Equipment
Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
Communication A BRITISH MANUFACTURER. Features:
care2 Radial Wired Emergency Voice Communication Manufacturing EVC systems since 2001 CARE2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall.
466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: 60-883-95R. CareGard. User Guide
) *(6HFXULW\ 466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP Part No: 60-883-95R CareGard User Guide FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by GE Security
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,
Using your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine
SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS
SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment
Introduction Ericsson Handheld Telephone 1341-B
Ericsson Handheld Telephone 1341-B 2 Contents General 5 The Mobile Telephone Network 6 Base Station and Cell 7 Radio Channels 7 Radio Coverage 8 Transmission Control and Communication 9 Quality Control
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line
INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description
INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's
Wireless Home Security System
Wireless Home Security System Group: D14 Members: Vaibhav Singh (05D07026) Abhishek Tiwari (05D07028) Sauvik Chowdhury (05D07029) 1. Abstract The project is aimed at designing a low cost and reliable wireless
Advanced Fencing and Security Technologies Ltd
G.M. Advanced Fencing and Security Technologies Ltd P.O. Box 2327 Kfar Sava Industrial Area 44425, Israel Tel +972-9-7662965 Fax + 972-9-7662964 E-mail: [email protected] Website: www.gmsecurity.com
A-307. Mobile Data Terminal. Android OS Platform Datasheet
A-307 Mobile Data Terminal Android OS Platform Datasheet Revision 1.1 July, 2013 Introduction A-307 Platform Overview Introduction A-307 Platform Overview The A-307 provides Original Equipment Manufacturers
CATALOG NUMBER. Features. Description
VOICE EVACUATION SYSTEM QX000 SERIES Description Mircom s QX000 Series is a multichannel zoned audio system that allows the operator to selectively page from a central location to any of the system s audible
Residential Gateway (RG) Battery Backup
Residential Gateway (RG) Battery Backup BU3DC000-12V User Manual Table of Contents Page Introduction... 3 Safety Information... 3 System Requirements... 3 Package Contents... 4 Recycling... 4 Product Layout
Manual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
DTW Works Master Specification Version 2006
Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
InHome Water Leak Detection Package
InHome Water Leak Detection Package For Model Numbers ILD10A-L and ILD10A-B Installation Guide / Wiring Diagram For Creating Water Leak Detection-based Events with Line-Powered or Battery-Powered Sensors
HERNANDO COUNTY FIRE ALARM GUIDELINES
HERNANDO COUNTY FIRE ALARM GUIDELINES To be used for all commercial building fire alarm system plan review. The procedures set forth in this document are the minimum requirements necessary to ensure a
PC Tab Security System INSTRUCTION MANUAL
PC Tab Security System INSTRUCTION MANUAL This manual is intended as a Quick Start manual covering the basic functions that have been enabled on the alarm panel. The alarm panel is capable of extensive
CAPTAIN 6. USER GUIDE System ver. 6.0. 6 Zones Intruder Alarm System. PIMA Electronic Systems Ltd. www.pima-alarms.com
CAPTAIN 6 6 Zones Intruder Alarm System USER GUIDE System ver. 6.0 PIMA Electronic Systems Ltd. www.pima-alarms.com P/N 4410049, G2 XX en, Jan. 2010 2 CAPTAIN 6 User Guide SAFETY INSTRUCTIONS Your CAPTAIN-i
Middleborough Police Electronic Security Narrative
Middleborough Police Electronic Security Narrative 1. PURPOSE The purpose of this document is to define specific security, access control and surveillance requirements for the exterior and interior of
Manual. VE.Bus to NMEA 2000 interface
Manual EN VE.Bus to NMEA 2000 interface Copyrights 2010 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose. For
Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand
Elite 8D/Lite Version 8 Zone Controller 8 Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand 2 CONTENTS Page No. INTRODUCTION 4 About your Alarm 4 OPERATING
CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS
CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS PROPERTY ADDRESS (BRT Address Required) TESTING CONTRACTOR (Name and Address) License No. ANNUAL
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)
FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service) The information provided in this user guide pertains to fire suppression sprinkler system monitoring service provided over
ACE AUTODIALLER MANUAL FOR LIFT COMPANY
ACE AUTODIALLER MANUAL FOR LIFT COMPANY 1 2 Information to the Building Owner. In June 2003 the harmonised standard BSEN81-28 came into effect. The standard states that it is the building owners responsibility
DIGITUS Network & Server Cabinets. UNIQUE Series
DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door
FDCI222, FDCIO222, FDCIO224 Input module Input/output modules
FDCI222, FDCIO222, FDCIO224 Input module Input/output modules addressable (FDnet/C-NET) Sinteso Cerberus PRO Input module FDCI222 with 4 monitored contact inputs for the acknowledgement of technical states
Low Power FM Site Monitoring Kit
Low Power FM Site Monitoring Kit Keep your station fully compliant with FCC rules! FCC rules for unattended operation of LPFM stations require that all installations have a tamper-proof monitoring and
Notifier by Honeywell: Voice Alarm Solutions
Notifier by Honeywell: Voice Alarm Solutions Notifier by Honeywell: Voice Alarm The role of Voice Alarm As modern buildings become more complex, it is vital to manage people safely in an emergency. Voice
Security Systems Intrusion Alarm
Dufferin-Peel Catholic District School Board STANDARD TEXT GUIDELINE FOR Security Systems for SECONDARY AND ELEMENTARY SCHOOLS Prepared by the Plant Department With Assistance from Vision Dynamics Formatted
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space
CC-Link Communication Unit * FASTUS is a product brand of Optex FA. Monitor and control the sensors through network supported Remote controlling of fiber sensors Reduces wires and saves space OPTEX FA
PLAN REVIEW GUIDE FOR FIRE ALARM
PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical
A world first: pro sound and voice alarm systems from Bosch obtain EN 54 certification
A world first: pro sound and voice alarm systems from Bosch obtain EN 54 certification Bosch is the first supplier worldwide to offer voice alarm systems with integrated pro sound components compliant
Data Center Presentation
Data Center Presentation The NetSource Datacenter. Agenda General Layout of Data Center Policies and Procedures Designed to Latest Standards High Performance High Reliability High Security Design Details
Fire alarm system EBL512 G3
Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Generation three G3. Internet: pesn.panasonic.se 2011-03-24 Page 1 of 6 The demands
Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6
Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit
Combi B Alarm box. Mounting instructions
Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power
sat-nms SMU Signal Management Unit
sat-nms SMU Signal Management Unit Application Note 2014, SatService GmbH www.satnms.com SMU-APP-1408-1 1/37 1 System Description and Configuration of sat-nms SMU The sat-nms SMU is the unit you were always
ANNEX 11. RESOLUTION MSC.128(75) (adopted on 20 May 2002) PERFORMANCE STANDARDS FOR A BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS)
RESOLUTION MSC.128(75) (adopted on 20 May 2002) PERFORMANCE STANDARDS FOR A BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) THE MARITIME SAFETY COMMITTEE, RECALLING Article (28(b) of the Convention on the
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting