Miniature Circuit Breakers and Supplementary Protectors

Similar documents
Product Guide. Cable-in / cable-out miniature circuit breakers and supplementary protectors

LCP Coordination Panel Operations & Maintenance Manual Table of Contents

Reverse-feed applications for circuit breakers

Tmax MCCBs. Molded case circuit breakers. Tmax

PREFACE. The products covered by this Guide are:

Bolted contact switches. Pringle switches

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

QO and QOB Miniature Circuit Breakers

Bulletin 1489 Circuit Breakers. Selection Guide

Circuit Breakers Supplementary Protectors Manual Motor Controllers

8146/5 Series Breaker Panelboards

Circuit Breaker. Description

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Power Distribution & Terminal Blocks

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Circuit Breakers. Next Generation of Protection Capabilities

AC1645. System pro M compact Supplementary Protectors Miniature MCCBs

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Molded case circuit breakers

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Circuit Breakers. NRC Series. NRC Series

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

How To Test A Power Switch On A Power Supply

Mini Power-Zone Unit Substation

Sentron Series Circuit Breakers

Lighting Control System Catalog. Class 1210

Contactors Low Voltage

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers

DCS Input/Output Relay Card Series

Remote Power Panels with Breakers

Power Management Module 2. Installation

LVA Take Offs in Bid Manager

Mission Critical Data Center Systems

Bimetallic Overload Relay Specifications

Equipment. Metering. Metering Equipment 1. Contents

Arc Fault Circuit Interrupters Frequently Asked Questions

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Molded-Case Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers

Index Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers

BETA Protecting SITOR Semiconductor Fuses

Tmax. Molded case circuit breakers. Phone: Fax: Web: info@clrwtr.com. Tmax.

Motor Control and Protection

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

INSTALLATION INSTRUCTIONS

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

40.3. Control Relays and Timers

Distribution Dry Type Transformers

Intersection Preassembled 19-inch Rack

Mining service breakers with true rms sensing designed specifically for trailing cable applications

Mining service breakers with true rms sensing designed specifically for trailing cable applications

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Datasheet. AC Outlet DIN-Rail Mountable Receptacles

R.C.C.B. s two-pole LEXIC

Electronic overload relay EF19 and EF45

Installation instructions for Series NRX INCOM communications adapter module

Power Outlet Panels. Product Guide

Definite Purpose Contactors and Starters

Catalog January. Heavy industrial power applications Motor contactors and starters

Terminal Blocks & Power Distribution Terminal Blocks. Make your connection

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

TSn SERIES Surge Protective Device

General information Circuit breakers for power distribution T1 T3

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Solid-State Timer H3G

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

THERMAL MANAGEMENT SOLUTIONS

MCC Ratings. Voltage Rating

General-purpose Relay

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

ASSEMBLED SOCKET-COMBINATIONS

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Switching Power Module

CITY OF LOS ANGELES CALIFORNIA

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

Protect your home and family with Advanced Technology from Cutler-Hammer

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Retail Reference Guide Answers for infrastructure.

T1 Backhaul Connectivity Solution All Products :: Application Note

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

Rotary Disconnect Switch Specifications

65,000 A IR Catalog Number QA115AFCHH QA120AFCHH. 22,000 A IR Catalog Number. QA115AFHn a QA120AFHn a. Q215AFCHn a Q220AFCHn a QA115AFHH QA120AFHH

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760

Model #: SMART2200CRMXL

Overcurrent Protection

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Top Commercial / Residential Electrical Requirements *

Transcription:

Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors. Industrial Circuit Breakers QUICKLAG............................................. QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW........... QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP.................... Bolt-On Types BAB, QBHW, HBAX, HBAW..................... Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF......... V4-T-2 V4-T-5 V4-T-8 V4-T- V4-T-4 Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP.................... V4-T-7 Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW....... Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH.......................................... Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP.................... Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP..................... Solenoid Operator Remote-Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers................... International Rated Types HQP, BA, QC, GFMB, GFXBC........... Special Application Breakers, Types HQP, BA, QC............... V4-T-20 V4-T-24 V4-T-28 V4-T-3 V4-T-34 V4-T-37 V4-T-40.2 UL 489 DIN Rail Miniature Circuit Breakers FAZ-NA Circuit Breakers....................................3 UL 077 DIN Rail Supplementary Protectors FAZ Circuit Breakers...................................... V4-T-49 V4-T-67.4 UL 053 DIN Rail RCCB UL 053 DIN Rail RCCB 480/277 Vac......................... UL 053 DIN Rail RCCB 208Y/20 Vac........................ V4-T-87 V4-T-93 Learn Online Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-

. Industrial Circuit Breakers QUICKLAG Quick Reference Contents Description Quick Reference Eaton s QUICKLAG Industrial Circuit Breakers Plug-In, Bolt-On, Cable-In/Cable-Out Continuous Interrupting Ratings rms Symmetrical Amperes Circuit Ampere Federal Vac Ratings Vdc Ratings 2 Breaker Circuit Breaker Rating of Spec. Type Type Code at 40 C Poles Vac Vdc W-C-375b 20 20/240 240 24 48 62.5 80 HQP P 0 70 20/240 24, 48, 62.5 0a, a, 2a 0,000 5000 3 V4-T-6 Notes QUICKLAG circuit breakers are suitable for application in relative humidity 0 95% noncondensing. 2 Two-pole DC interrupting ratings based on two poles connected in series. Not UL listed. 3 62.5 Vac interrupting rating is 3800 AIC 0 50A and 2500 AIC 55 00A continuous. Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 ma; GFEP Ground Fault, 30 ma. For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see Pages V4-T-3 to V4-T-36. Page HQP P 0 25 2 20/240 24, 48, 80 0a, 2a 0,000 5000 5000 5000 V4-T-6 HQP P 0 00 2, 3 240 0b, b, 2b 0,000 V4-T-6 QPHW P 5 70 20/240 24, 48, 62.5 4a 22,000 5000 3 V4-T-6 QPHW P 5 25 2 20/240 24, 48, 80 4a 22,000 5000 5000 5000 V4-T-6 QPHW P 5 00 2, 3 240 4b 22,000 V4-T-6 QHPX P 5 70 20/240 24, 48, 62.5 42,000 5000 3 V4-T-7 QHPX P 5 00 2 20/240 24, 48, 80 42,000 5000 5000 5000 V4-T-7 QHPX P 5 00 3 240 42,000 V4-T-7 QHPW P 5 30 20/240 24, 48, 62.5 5a 65,000 5000 3 V4-T-7 QHPW P 5 30 2 20/240 24, 48, 80 5a 65,000 5000 5000 5000 V4-T-7 QHPW P 5 20 3 240 5b 65,000 V4-T-7 QPGF P, GF 5 40 20 0a, a, 2a 0,000 V4-T-9 QPGF P, GF 5 50 2 20/240 0a, a, 2a 0,000 V4-T-9 V4-T-2 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. Eaton s QUICKLAG Industrial Circuit Breakers Plug-In, Bolt-On, Cable-In/Cable-Out, continued Continuous Interrupting Ratings rms Symmetrical Amperes Circuit Ampere Federal Vac Ratings Vdc Ratings 2 Breaker Circuit Breaker Rating of Spec. Type Type Code at 40 C Poles Vac Vdc W-C-375b 20 20/240 240 24 48 62.5 80 Notes QUICKLAG circuit breakers are suitable for application in relative humidity 0 95% noncondensing. 2 Two-pole DC interrupting ratings based on two poles connected in series. Not UL listed. 3 62.5 Vac interrupting rating is 3800 AIC 0 50A and 2500 AIC 55 00A continuous. Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 ma; GFEP Ground Fault, 30 ma. For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see Pages V4-T-3 to V4-T-36. Page QPHGF P, GF 5 30 20 0a, a, 2a 22,000 V4-T-9 QPHGF P, GF 5 50 2 20/240 0a, a, 2a 22,000 V4-T-9 QPGFEP P, GFEP 5 40 20 0,000 V4-T-9 QPGFEP P, GFEP 5 50 2 20/240 0,000 V4-T-9 QPHGFEP P, GFEP 5 30 20 22,000 V4-T-9 BABRSP B 5 30 20 0,000 V4-T-2 BABRSP B 5 30 2 20/240 0,000 V4-T-2 BRRP P 5 30 20 0,000 V4-T-32 BRRP P 5 30 2 20/240 0,000 V4-T-32 CLRP P 5 30 20 0,000 V4-T-32 CLRP P 5 30 2 20/240 0,000 V4-T-32 BAB B 0 70 20/240 24, 48, 62.5 0a, a, 2a 0,000 5000 3 V4-T-2 BAB B 0 25 2 20/240 24, 48, 80 0a, 2a 0,000 5000 5000 5000 V4-T-2 BAB B 0 00 2, 3 240 0b, b, 2b 0,000 V4-T-2 BABRP B 5 30 20 0,000 V4-T-32 BABRP B 5 30 2 20/240 0,000 V4-T-32 QBAF B, AF 5 20, 2 20/240 0,000 V4-T-5 QBCAF B, AF, GF 5 20, 2 20/240 0,000 V4-T-5 QBHW B 5 70 20/240 24, 48, 62.5 4a 22,000 5000 3 V4-T-2 QBHW B 5 25 2 20/240 24, 48, 80 4a 22,000 5000 5000 5000 V4-T-2 QBHW B 5 00 2, 3 240 4b 22,000 V4-T-2 HBAX B 5 70 20/240 24, 48, 62.5 42,000 5000 3 V4-T-3 HBAX B 5 00 2 20/240 24, 48, 80 42,000 5000 5000 5000 V4-T-3 HBAX B 5 00 3 240 42,000 V4-T-3 HBAW B 5 30 20/240 24, 48, 62.5 5a 65,000 5000 3 V4-T-3 HBAW B 5 30 2 20/240 24, 48, 80 5a 65,000 5000 5000 5000 V4-T-3 HBAW B 5 20 3 240 5b 65,000 V4-T-3 QBGF B, GF 5 40 20 0a, a, 2a 0,000 V4-T-8 QBGF B, GF 5 50 2 20/240 0a, a, 2a 0,000 V4-T-8 QBHGF B, GF 5 30 20 0a, a, 2a 22,000 V4-T-8 QBHGF B, GF 5 30 20/240 0a, a, 2a 22,000 V4-T-8 QBGFEP B, GFEP 5 40 20 0,000 V4-T-8 QBGFEP B, GFEP 5 50 2 20/240 0,000 V4-T-8 QBHGFEP B, GFEP 5 30 20 22,000 V4-T-8 QBHGFEP B, GFEP 5 30 2 20/240 22,000 22,000 V4-T-8 QC C 0 70 20/240 24, 48, 62.5 0a, a, 2a 0,000 5000 3 V4-T-4 QC C 0 00 2 20/240 24, 48, 80 0a, 2a 0,000 5000 5000 5000 V4-T-4 QC C 0 00 2, 3, 4 240 0b, b, 2b 0,000 V4-T-4 QCD C 0 60, 2 20/240 24, 48, 62.5 0,000 0,000 3000 3000 V4-T-23 QCD C 0 00 2, 3 240 24, 48, 62.5 0,000 3000 3000 V4-T-23 QCF C 0 60, 2 20/240 24, 48, 62.5 0,000 0,000 3000 3000 V4-T-42 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-3

. Industrial Circuit Breakers Eaton s QUICKLAG Industrial Circuit Breakers Plug-In, Bolt-On, Cable-In/Cable-Out, continued Continuous Interrupting Ratings rms Symmetrical Amperes Circuit Circuit Ampere Federal Vac Ratings Vdc Ratings 2 Breaker Breaker Rating of Spec. Type Type Code at 40 C Poles Vac Vdc W-C-375b 20 20/240 240 24 48 62.5 80 Notes QUICKLAG circuit breakers are suitable for application in relative humidity 0 95% noncondensing. 2 Two-pole DC interrupting ratings based on two poles connected in series. Not UL listed. 3 62.5 Vac interrupting rating is 3800 AIC 0 50A and 2500 AIC 55 00A continuous. Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 ma; GFEP Ground Fault, 30 ma. For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see Pages V4-T-3 to V4-T-36. Page QCF C 5 20, 2 20/240 24, 48, 62.5 22,000 3000 3000 V4-T-27 QCF C 5 30 2, 3 240 24, 48, 62.5 0,000 3000 3000 V4-T-27 QCR C 0 60, 2 20/240 24, 48, 62.5 0,000 0,000 3000 3000 V4-T-27 QCR C 5 20, 2 20/240 24, 48, 62.5 22,000 3000 3000 V4-T-27 QCR C 5 30 2, 3 240 24, 48, 62.5 0,000 3000 3000 V4-T-27 QCHW C 5 70 20/240 24, 48, 62.5 4a 22,000 5000 3 V4-T-22 QCHW C 5 00 2 20/240 24, 48, 80 4a 22,000 5000 5000 5000 V4-T-22 QCHW C 5 00 2, 3 240 4b 22,000 V4-T-22 QHCX C 5 70 20/240 24, 48, 62.5 42,000 5000 3 V4-T-22 QHCX C 5 00 2 20/240 24, 48, 80 42,000 5000 5000 5000 V4-T-22 QHCX C 5 00 3 240 42,000 V4-T-22 QHCW C 5 30 20/240 24, 48, 62.5 5a 65,000 5000 3 V4-T-22 QHCW C 5 30 2 20/240 24, 48, 80 5a 65,000 5000 5000 5000 V4-T-22 QHCW C 5 20 3 240 5b 65,000 V4-T-22 QCGF C, GF 5 40 20 0,000 V4-T-29 QCGF C, GF 5 50 2 20/240 0,000 V4-T-29 QCHGF C, GF 5 30 20 22,000 V4-T-29 QCHGF C, GF 5 30 2 20/240 22,000 V4-T-29 QCGFEP C, GFEP 5 40 20 0,000 V4-T-29 QCGFEP C, GFEP 5 50 2 20/240 0,000 V4-T-29 QCHGFEP C, GFEP 5 30 20 22,000 V4-T-29 QCHGFEP C, GFEP 5 30 2 20/240 22,000 V4-T-29 V4-T-4 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. QUICKLAG Type HQP Single-Pole Contents Description Quick Reference.............................. QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW Product Selection........................ Dimensions............................. QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW......... Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF............................... Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP........ Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW.............................. Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH............................... Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP......... Solenoid Operator Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers........ International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC.... Page V4-T-2 V4-T-6 V4-T-7 V4-T-8 V4-T- V4-T-4 V4-T-7 V4-T-20 V4-T-24 V4-T-28 V4-T-3 V4-T-34 V4-T-37 V4-T-40 QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW Product Description Standards and Certifications All products 5 00A are HACR rated Switching duty rated for 20 Vac fluorescent light applications Built and listed to UL 489 All products UL and CSA listed Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-5

. Industrial Circuit Breakers Product Selection QUICKLAG Type HQP Single-Pole QUICKLAG Type: HQP 0,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C 0 HQP00 HQP200 HQP300H 3 5 HQP05 2 HQP205 HQP205H HQP305H 20 HQP020 2 HQP2020 HQP2020H HQP3020H 25 HQP025 HQP2025 HQP2025H HQP3025H 30 HQP030 HQP2030 HQP2030H HQP3030H 35 HQP035 HQP2035 HQP2035H HQP3035H 40 HQP040 HQP2040 HQP2040H HQP3040H 45 HQP045 HQP2045 HQP2045H HQP3045H 50 HQP050 HQP2050 HQP2050H HQP3050H 55 HQP055 HQP2055 HQP2055H HQP3055H 60 HQP060 HQP2060 HQP2060H HQP3060H 70 HQP070 HQP2070 HQP2070H HQP3070H 80 HQP2080 HQP2080H HQP3080H 90 HQP2090 HQP2090H HQP3090H 00 HQP00 HQP200 HQP200H HQP300H 0 HQP20 25 HQP225 50 HQP250 QUICKLAG Type: HQP Non-Automatic Switches Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C 50 HQP050N HQP2050N HQP3050N 60 HQP060N HQP2060N HQP3060N 00 HQP00N HQP200N HQP300N QUICKLAG Type: QPHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C 5 QPHW05 QPHW205 QPHW205H QPHW305H 20 QPHW020 QPHW2020 QPHW2020H QPHW3020H 25 QPHW025 QPHW2025 QPHW2025H QPHW3025H 30 QPHW030 QPHW2030 QPHW2030H QPHW3030H 35 QPHW035 QPHW2035 QPHW2035H QPHW3035H 40 QPHW040 QPHW2040 QPHW2040H QPHW3040H 45 QPHW045 QPHW2045 QPHW2045H QPHW3045H 50 QPHW050 QPHW2050 QPHW2050H QPHW3050H 55 QPHW055 QPHW2055 QPHW2055H QPHW3055H 60 QPHW060 QPHW2060 QPHW2060H QPHW3060H 70 QPHW070 QPHW2070 QPHW2070H QPHW3070H 80 QPHW2080 QPHW2080H QPHW3080H 90 QPHW2090 QPHW2090H QPHW3090H 00 QPHW200 QPHW200H QPHW300H 0 QPHW20 25 QPHW225 Notes Switching duty rated for 20 Vac fluorescent light applications. 2 For special low-magnetic breaker, order HQP05L or HQP020L. 3 Not UL listed. V4-T-6 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. QUICKLAG Type: QHPX 42,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C 5 QHPX05 QHPX205 QHPX305H 20 QHPX020 QHPX2020 QHPX3020H 25 QHPX025 QHPX2025 QHPX3025H 30 QHPX030 QHPX2030 QHPX3030H 35 QHPX035 QHPX2035 QHPX3035H 40 QHPX040 QHPX2040 QHPX3040H 45 QHPX045 QHPX2045 QHPX3045H 50 QHPX050 QHPX2050 QHPX3050H 55 QHPX055 QHPX2055 QHPX3055H 60 QHPX060 QHPX2060 QHPX3060H 70 QHPX070 QHPX2070 QHPX3070H 80 QHPX2080 QHPX3080H 90 QHPX2090 QHPX3090H 00 QHPX200 QHPX300H QUICKLAG Type: QHPW 65,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C 5 QHPW05 QHPW205 QHPW305H 20 QHPW020 QHPW2020 QHPW3020H 25 QHPW025 QHPW2025 30 QHPW030 QHPW2030 Dimensions Approximate Dimensions in Inches (mm) Shipping Data Carton Approximate of Poles Quantity Weight Lbs (kg) Dimensions 24 9.00 (4.) 2.50 x 7.50 x 5.00 (37.5 x 90.5 x 27.0) 2 2 9.00 (4.) 2.50 x 7.50 x 5.00 (37.5 x 90.5 x 27.0) 3 8 9.00 (4.) 2.50 x 7.50 x 5.00 (37.5 x 90.5 x 27.0) Note Switching duty rated for 20 Vac fluorescent light applications. Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-7

. Industrial Circuit Breakers QUICKLAG Type QPGF Single-Pole Ground Fault Circuit Breaker QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Product Description Standards and Certifications QUICKLAG Ground Fault Circuit Breakers, Class A GFCI 5 ma trip sensitivity QUICKLAG Ground Fault Equipment Protectors 30 ma trip sensitivity Built and listed to UL 489 QUICKLAG Ground Fault Circuit Breakers, Class A GFCI Built and tested to UL 943 QUICKLAG Ground Fault Equipment Protectors Built and listed to UL 053 Contents Description Quick Reference............................. QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Product Selection........................ Wiring Diagram.......................... Dimensions............................. Bolt-On Types BAB, QBHW, HBAX, HBAW........ Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF.............................. Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP....... Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW............................. Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH.............................. Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP......... Solenoid Operator Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers....... International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC... Page V4-T-2 V4-T-5 V4-T-9 V4-T-0 V4-T-0 V4-T- V4-T-4 V4-T-7 V4-T-20 V4-T-24 V4-T-28 V4-T-3 V4-T-34 V4-T-37 V4-T-40 V4-T-8 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. Product Selection QUICKLAG Type QPGF Single-Pole Ground Fault Circuit Breakers 5 ma Sensitivity QUICKLAG Type: QPGF 0,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40 C Single-Pole Two-Pole 20 Vac 20/240 Vac 5 QPGF05 QPGF205 20 QPGF020 QPGF2020 25 QPGF025 QPGF2025 30 QPGF030 QPGF2030 40 QPGF040 QPGF2040 50 QPGF2050 QUICKLAG Type: QPHGF 22,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40 C Single-Pole Two-Pole 20 Vac 20/240 Vac 5 QPHGF05 QPHGF205 20 QPHGF020 QPHGF2020 25 QPHGF025 QPHGF2025 30 QPHGF030 QPHGF2030 Ground Fault Equipment Breakers 30 ma Sensitivity QUICKLAG Type: QPGFEP 0,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40 C Single-Pole Two-Pole 20 Vac 20/240 Vac 5 QPGFEP05 QPGFEP205 20 QPGFEP020 QPGFEP2020 25 QPGFEP025 QPGFEP2025 30 QPGFEP030 QPGFEP2030 40 QPGFEP040 QPGFEP2040 50 QPGFEP2050 QUICKLAG Type: QPHGFEP 22,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40 C Single-Pole Two-Pole 20 Vac 20/240 Vac 5 QPHGFEP05 QPHGFEP205 20 QPHGFEP020 QPHGFEP2020 25 QPHGFEP025 QPHGFEP2025 30 QPHGFEP030 QPHGFEP2030 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-9

. Industrial Circuit Breakers Special Application Ground Fault Circuit Protectors 5 ma Sensitivity QUICKLAG Type: QPGF 0,000A Interrupting Capacity with Bell Alarm (W) or Auxiliary Switch (W2) Single-Pole Two-Pole Continuous Ampere Rating 20 Vac 20/240 Vac at 40 C 5 QPGF05W QPGF205W 20 QPGF020W QPGF2020W 25 QPGF025W QPGF2025W 30 QPGF030W QPGF2030W 40 QPGF2040W 50 QPGF2050W 5 QPGF05W2 20 QPGF020W2 25 QPGF025W2 30 QPGF030W2 Special Application Ground Fault Circuit Protectors 30 ma Sensitivity QUICKLAG Type: QPGFEP 0,000A Interrupting Capacity with Bell Alarm (W) or Auxiliary Switch (W2) Single-Pole Two-Pole Continuous Ampere Rating 20 Vac 20/240 Vac at 40 C 5 QPGFEP05W QPGFEP205W 20 QPGFEP020W QPGFEP2020W 25 QPGFEP025W QPGFEP2025W 30 QPGFEP030W QPGFEP2030W 40 QPGFEP2040W 50 QPGFEP2050W 5 QPGFEP05W2 20 QPGFEP020W2 25 QPGFEP025W2 30 QPGFEP030W2 Wiring Diagram Bell Alarm and Auxiliary Contact Schematic Ground Fault Breaker Dimensions Approximate Dimensions in Inches (mm) Shipping Data of Poles Blue Red Note Shipped individually or in carton quantities. Blue Wire Black Wire Red Wire Single-throw double-pole contacts are UL and CSA listed for 5A at 250 Vac. Bell Alarm (W) contacts change state when breaker trips. Auxiliary Switch (W2) contacts change state when breaker is opened (or tripped) or closed. 4-inch (355.6 mm) long 8 AWG pigtail wire leads provided. Carton Quantity NC NO Approximate Weight Lbs (kg) Dimensions 24.00 (5.0) 2.50 x 6.50 x 5.00 (37.5 x 65. x 27.0) 2 5 5.00 (2.3) 5.50 x 6.00 x 4.50 (393.7 x 52.4 x 4.3) V4-T-0 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. QUICKLAG Type BAB Single-Pole Contents Description Quick Reference.............................. QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW Product Selection........................ Dimensions............................. Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF............................... Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP........ Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW.............................. Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH............................... Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP......... Solenoid Operator Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers........ International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC.... Page V4-T-2 V4-T-5 V4-T-8 V4-T-2 V4-T-3 V4-T-4 V4-T-7 V4-T-20 V4-T-24 V4-T-28 V4-T-3 V4-T-34 V4-T-37 V4-T-40 Bolt-On Types BAB, QBHW, HBAX, HBAW Product Description Standards and Certifications All products 5 00A are HACR rated Switching duty rated for 20 Vac fluorescent light applications Built and listed to UL 489 All products UL and CSA listed Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-

. Industrial Circuit Breakers Product Selection QUICKLAG Type BAB Single-Pole QUICKLAG Type: BA 0,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C 0 BAB00 BAB200 BAB200H 3 BAB300H 3 5 BAB05 2 BAB205 BAB205H BAB305H 20 BAB020 2 BAB2020 BAB2020H BAB3020H 25 BAB025 BAB2025 BAB2025H BAB3025H 30 BAB030 BAB2030 BAB2030H BAB3030H 35 BAB035 BAB2035 BAB2035H BAB3035H 40 BAB040 BAB2040 BAB2040H BAB3040H 45 BAB045 BAB2045 BAB2045H BAB3045H 50 BAB050 BAB2050 BAB2050H BAB3050H 55 BAB055 BAB2055 BAB2055H BAB3055H 60 BAB060 BAB2060 BAB2060H BAB3060H 70 BAB070 BAB2070 BAB2070H BAB3070H 80 BAB2080 BAB2080H BAB3080H 90 BAB2090 BAB2090H BAB3090H 00 BAB00 BAB200 BAB200H BAB300H 0 BAB20 25 BAB225 QUICKLAG Type: BA Non-Automatic Switches Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C 50 BAB050N BAB2050N BAB3050N 60 BAB060N BAB2060N BAB3060N 00 BAB00N BAB200N BAB300N QUICKLAG Type: QBHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C 5 QBHW05 QBHW205 QBHW205H QBHW305H 20 QBHW020 QBHW2020 QBHW2020H QBHW3020H 25 QBHW025 QBHW2025 QBHW2025H QBHW3025H 30 QBHW030 QBHW2030 QBHW2030H QBHW3030H 35 QBHW035 QBHW2035 QBHW2035H QBHW3035H 40 QBHW040 QBHW2040 QBHW2040H QBHW3040H 45 QBHW045 QBHW2045 QBHW2045H QBHW3045H 50 QBHW050 QBHW2050 QBHW2050H QBHW3050H 55 QBHW055 QBHW2055 QBHW2055H QBHW3055H 60 QBHW060 QBHW2060 QBHW2060H QBHW3060H 70 QBHW070 QBHW2070 QBHW2070H QBHW3070H 80 QBHW2080 QBHW2080H QBHW3080H 90 QBHW2090 QBHW2090H QBHW3090H 00 QBHW200 QBHW200H QBHW300H 0 QBHW20 25 QBHW225 Notes Switching duty rated for 20 Vac fluorescent light applications. 2 For special low-magnetic breaker, order BAB05L or BAB020L. 3 Not UL listed. V4-T-2 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. QUICKLAG Type: HBAX 42,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C 5 HBAX05 HBAX205 HBAX305H 20 HBAX020 HBAX2020 HBAX3020H 25 HBAX025 HBAX2025 HBAX3025H 30 HBAX030 HBAX2030 HBAX3030H 35 HBAX035 HBAX2035 HBAX3035H 40 HBAX040 HBAX2040 HBAX3040H 45 HBAX045 HBAX2045 HBAX3045H 50 HBAX050 HBAX2050 HBAX3050H 55 HBAX055 HBAX2055 HBAX3055H 60 HBAX060 HBAX2060 HBAX3060H 70 HBAX070 HBAX2070 HBAX3070H 80 HBAX2080 HBAX3080H 80 HBAX2080 HBAX3080H 90 HBAX2090 HBAX3090H 00 HBAX200 HBAX300H QUICKLAG Type: HBAW 65,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C 5 HBAW05 HBAW205 HBAW305H 20 HBAW020 HBAW2020 HBAW3020H 25 HBAW025 HBAW2025 30 HBAW030 HBAW2030 Dimensions Approximate Dimensions in Inches (mm) Shipping Data Carton Approximate of Poles Quantity Weight Lbs (kg) Dimensions 24 9.00 (4.) 2.50 x 7.50 x 5.00 (37.5 x 90.5 x 27.0) 2 2 9.00 (4.) 2.50 x 7.50 x 5.00 (37.5 x 90.5 x 27.0) 3 8 9.00 (4.) 2.50 x 7.50 x 5.00 (37.5 x 90.5 x 27.0) Note Switching duty rated for 20 Vac fluorescent light applications. Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-3

. Industrial Circuit Breakers Bolt-On Arc Fault Circuit Interrupter QUICKLAG Types QBAF, QBCAF Contents Description Quick Reference............................. QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW........ Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF Product Selection........................ Wiring Diagrams......................... Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP....... Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW............................. Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH.............................. Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP......... Solenoid Operator Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers....... International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC... Page V4-T-2 V4-T-5 V4-T-8 V4-T- V4-T-5 V4-T-6 V4-T-7 V4-T-20 V4-T-24 V4-T-28 V4-T-3 V4-T-34 V4-T-37 V4-T-40 Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF Product Description All products HACR rated Features, Benefits and Functions 0 and 22 kaic rating at 20V and 20/240V Single-pole AFCI HID ratings for HID (High Intensity Discharge) lighting All models are HACR rated Standards and Certifications Built and listed to UL 489 UL File E789 for QBAF V4-T-4 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. Product Selection QBHCAF QBCAF and QBAF Type AFCIs Effective immediately, Eaton AFCIs are available for use in Sumter panels with a 22 kaic rating. This higher rated breaker will allow us to win jobs where AFCIs are specified at higher than 0 kaic. This breaker provides standard thermalmagnetic protection of branch circuits. This product will have the same form, fit and function of the current bolt-on AFCI (QBCAF and QBAF Type). Product scope is below. These breakers are in Bid Manager for Pow-R- Line a, Pow-R-Line a-lx, -Inch (25.4 mm) Wide Bolt-On Arc Fault Circuit Interrupter Poles kaic Rating Pow-R-Line 3a and Pow-R- Line 4a panelboards. For series rated combinations, continue to use the less expensive 0 kaic QBCAF and QBAF offerings. Breakers can also be ordered from Vista. Ampere Rating Configuration Type QBCAF Combination AFCI Single-pole 0 kaic 5 Combination AFCI QBCAF05 20 Combination AFCI QBCAF020 22 kaic 5 Combination AFCI QBHCAF05 20 Combination AFCI QBHCAF020 Type QBAF Branch Feeder AFCI Single-pole 0 kaic 5 Branch Feeder AFCI QBAF05 20 Branch Feeder AFCI QBAF020 22 kaic 5 Branch Feeder AFCI QBHAF05 20 Branch Feeder AFCI QBHAF020 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-5

. Industrial Circuit Breakers Wiring Diagrams Single-Pole 20V Load Application Sourced by 20/240 Vac 20/240 Vac Source N A B Neutral Single-Pole Line B Neutral 20V Duplex Receptacle Equipment Ground Single-Pole Shared Neutral with Multi-Duplex Receptacle Application 20/240 Vac Source NA B Neutral Two-Pole Line B Neutral Line A Equipment Ground Two 20V Duplex Receptacles V4-T-6 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. QUICKLAG Type QBGF Single-Pole Ground Fault Circuit Breaker Contents Description QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW......... Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF............................... Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP Product Selection........................ Wiring Diagram.......................... Dimensions............................. Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW.............................. Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH............................... Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP......... Solenoid Operator Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers........ International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC.... Page V4-T-5 V4-T-8 V4-T- V4-T-4 V4-T-8 V4-T-9 V4-T-9 V4-T-20 V4-T-24 V4-T-28 V4-T-3 V4-T-34 V4-T-37 V4-T-40 Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP Product Description Standards and Certifications QUICKLAG Ground Fault Circuit Breakers, Class A GFCI 5 ma trip sensitivity QUICKLAG Ground Fault Equipment Protectors 30 ma trip sensitivity Built and tested to UL 489 QUICKLAG Ground Fault Circuit Breakers, Class A GFCI Built and tested to UL 943 QUICKLAG Ground Fault Equipment Protectors Built and tested to UL 053 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-7

. Industrial Circuit Breakers Product Selection QUICKLAG Type QBGF Single-Pole Ground Fault Circuit Breakers 5 ma Sensitivity QUICKLAG Type: QBGF 0,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40 C Single-Pole Two-Pole 20 Vac 20/240 Vac 5 QBGF05 QBGF205 20 QBGF020 QBGF2020 25 QBGF025 QBGF2025 30 QBGF030 QBGF2030 40 QBGF040 QBGF2040 50 QBGF2050 QUICKLAG Type: QBHGF 22,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40 C Single-Pole Two-Pole 20 Vac 20/240 Vac 5 QBHGF05 QBHGF205 20 QBHGF020 QBHGF2020 25 QBHGF025 QBHGF2025 30 QBHGF030 QBHGF2030 Ground Fault Equipment Breakers 30 ma Sensitivity QUICKLAG Type: QBGFEP 0,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40 C Single-Pole Two-Pole 20 Vac 20/240 Vac 5 QBGFEP05 QBGFEP205 20 QBGFEP020 QBGFEP2020 25 QBGFEP025 QBGFEP2025 30 QBGFEP030 QBGFEP2030 40 QBGFEP040 QBGFEP2040 50 QBGFEP2050 QUICKLAG Type: QBHGFEP 22,000A Interrupting Capacity Thermal-Magnetic Breakers Continuous Ampere Rating at 40 C Single-Pole Two-Pole 20 Vac 20/240 Vac 5 QBHGFEP05 QBHGFEP205 20 QBHGFEP020 QBHGFEP2020 25 QBHGFEP025 QBHGFEP2025 30 QBHGFEP030 QBHGFEP2030 V4-T-8 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. Special Application Ground Fault Circuit Protectors 5 ma Sensitivity QUICKLAG Type: QBGF 0,000A Interrupting Capacity with Bell Alarm (W) or Auxiliary Switch (W2) Single-Pole Two-Pole Continuous Ampere Rating 20 Vac 20/240 Vac at 40 C 5 QBGF05W QBGF205W 20 QBGF020W QBGF2020W 25 QBGF025W QBGF2025W 30 QBGF030W QBGF2030W 40 QBGF2040W 50 QBGF2050W 5 QBGF05W2 20 QBGF020W2 25 QBGF025W2 30 QBGF030W2 Special Application Ground Fault Circuit Protectors 30 ma Sensitivity QUICKLAG Type: QBGFEP 0,000A Interrupting Capacity with Bell Alarm (W) or Auxiliary Switch (W2) Single-Pole Two-Pole Continuous Ampere Rating 20 Vac 20/240 Vac at 40 C 5 QBGFEP05W QBGFEP205W 20 QBGFEP020W QBGFEP2020W 25 QBGFEP025W QBGFEP2025W 30 QBGFEP030W QBGFEP2030W 40 QBGFEP2040W 50 QBGFEP2050W 5 QBGFEP05W2 20 QBGFEP020W2 25 QBGFEP025W2 30 QBGFEP030W2 Wiring Diagram Bell Alarm and Auxiliary Contact Schematic Ground Fault Breaker Blue Red Dimensions Approximate Dimensions in Inches (mm) Shipping Data of Poles Approximate Weight Lbs (kg) Dimensions.00 (5.0) 2.50 x 6.50 x 5.00 (37.5 x 65. x 27.0) 2 5.00 (2.3) 5.50 x 6.00 x 4.50 (393.7 x 52.4 x 4.3) Note Shipped individually or in carton quantities. Blue Wire Black Wire Red Wire Single-throw double-pole contacts are UL and CSA listed for 5A at 250 Vac. Bell Alarm (W) contacts change state when breaker trips. Auxiliary Switch (W2) contacts change state when breaker is opened (or tripped) or closed. 4-inch (355.6 mm) long 8 AWG pigtail wire leads provided. NC NO Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-9

. Industrial Circuit Breakers QUICKLAG Type QC Single-Pole Contents Description Quick Reference............................. QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW........ Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF.............................. Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP....... Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW Product Selection........................ Dimensions............................. Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH.............................. Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP......... Solenoid Operator Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers....... International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC... Page V4-T-2 V4-T-5 V4-T-8 V4-T- V4-T-4 V4-T-7 V4-T-2 V4-T-23 V4-T-24 V4-T-28 V4-T-3 V4-T-34 V4-T-37 V4-T-40 Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW Product Description All products 0 00A are HACR rated Switching duty rated for 20 Vac fluorescent light applications only Standards and Certifications Built and listed to UL 489 All products UL and CSA listed V4-T-20 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. Product Selection QUICKLAG Type QC Single-Pole QUICKLAG Type: QC 0,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac 240 Vac at 40 C 5 QC005 QC2005 0 QC00 QC200 QC200H QC300H 5 QC05 2 QC205 QC205H QC305H QC405H 20 QC020 2 QC2020 QC2020H QC3020H QC4020H 25 QC025 QC2025 QC2025H QC3025H QC4025H 30 QC030 QC2030 QC2030H QC3030H QC4030H 35 QC035 QC2035 QC2035H QC3035H QC4035H 40 QC040 QC2040 QC2040H QC3040H QC4040H 45 QC045 QC2045 QC2045H QC3045H QC4045H 50 QC050 QC2050 QC2050H QC3050H QC4050H 55 QC055 QC2055 QC2055H QC3055H QC4055H 60 QC060 QC2060 QC2060H QC3060H QC4060H 70 QC070 QC2070 QC2070H QC3070H QC4070H 70 QC2080 QC2080H QC3080H QC4080H 90 QC2090 QC2090H QC3090H QC4090H 00 QC00 QC200 QC200H QC300H QC400H QUICKLAG Type: QC Non-Automatic Switches Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac 240 Vac at 40 C 50 QC050N QC2050N QC3050N 60 QC060N QC2060N QC3060N 00 QC00N QC200N QC300N Notes Not UL listed. 2 Switching duty rated for 20 Vac fluorescent light applications only. For special low-magnetic breaker, order QC05L or QC020L.Non-automatic switches, see Page V4-T-42. Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-2

. Industrial Circuit Breakers QUICKLAG Type: QCHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac 240 Vac at 40 C 5 QCHW05 QCHW205 QCHW205H QCHW305H QCHW405H 20 QCHW020 QCHW2020 QCHW2020H QCHW3020H QCHW4020H 25 QCHW025 QCHW2025 QCHW2025H QCHW3025H QCHW4025H 30 QCHW030 QCHW2030 QCHW2030H QCHW3030H QCHW4030H 35 QCHW035 QCHW2035 QCHW2035H QCHW3035H QCHW4035H 40 QCHW040 QCHW2040 QCHW2040H QCHW3040H QCHW4040H 45 QCHW045 QCHW2045 QCHW2045H QCHW3045H QCHW4045H 50 QCHW050 QCHW2050 QCHW2050H QCHW3050H QCHW4050H 55 QCHW055 QCHW2055 QCHW2055H QCHW3055H QCHW4055H 60 QCHW060 QCHW2060 QCHW2060H QCHW3060H QCHW4060H 70 QCHW070 QCHW2070 QCHW2070H QCHW3070H QCHW4070H 70 QCHW2080 QCHW2080H QCHW3080H QCHW4080H 90 QCHW2090 QCHW2090H QCHW3090H QCHW4090H 00 QCHW200 QCHW200H QCHW300H QCHW400H QUICKLAG Type: QHCX 42,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac 240 Vac at 40 C 5 QHCX05 QHCX205 QHCX305H 20 QHCX020 QHCX2020 QHCX3020H 25 QHCX025 QHCX2025 QHCX3025H 30 QHCX030 QHCX2030 QHCX3030H 35 QHCX035 QHCX2035 QHCX3035H 40 QHCX040 QHCX2040 QHCX3040H 45 QHCX045 QHCX2045 QHCX3045H 50 QHCX050 QHCX2050 QHCX3050H 55 QHCX055 QHCX2055 QHCX3055H 60 QHCX060 QHCX2060 QHCX3060H 70 QHCX070 QHCX2070 QHCX3070H 70 QHCX2080 QHCX3080H 90 QHCX2090 QHCX3090H 00 QHCX200 QHCX300H QUICKLAG Type: QHCW 65,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac 240 Vac at 40 C 5 QHCW05 QHCW205 QHCW305H 20 QHCW020 QHCW2020 QHCW3020H 25 QHCW025 QHCW2025 30 QHCW030 QHCW2030 Notes Switching duty rated for 20 Vac fluorescent light applications only. Non-automatic switches, see Page V4-T-42. V4-T-22 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. QUICKLAG Type QCD Miniature Circuit Breakers QCD breakers are used Flexible power feed primarily in HVAC and connection: industrial applications. wire size, position Single-, two- and three-pole options Same breaker size for entire rating range Modular construction DIN mounted (symmetrical rail 35 x 7.5 DIN/EN 50 022) QCD same profile as Type QCR QUICKLAG Type QCD Miniature Circuit Breaker Field mountable accessories: finger shroud proof, quick connect terminals Other accessories: jumper unit QUICKLAG Type QCD 0,000A Interrupting Capacity Thermal-Magnetic Breakers Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C QUICKLAG Type QCD Non-Automatic Switches Single-Pole Two-Pole Two-Pole Three-Pole Continuous Ampere Rating 20/240 Vac 20/240 Vac 240 Vac 240 Vac at 40 C Dimensions Approximate Dimensions in Inches (mm) Shipping Data of Poles 0 QCD00 QCD200 5 QCD05 QCD205 QCD205H QCD305H 20 QCD020 QCD2020 QCD2020H QCD3020H 25 QCD025 QCD2025 QCD2025H QCD3025H 30 QCD030 QCD2030 QCD2030H QCD3030H 35 QCD035 QCD2035 QCD2035H QCD3035H 40 QCD040 QCD2040 QCD2040H QCD3040H 45 QCD045 QCD2045 QCD2045H QCD3045H 50 QCD050 QCD2050 QCD2050H QCD3050H 55 QCD055 QCD2055 QCD2055H QCD3055H 60 QCD060 QCD2060 QCD2060H QCD3060H 70 QCD2070 QCD2070H QCD3070H 80 QCD2080 QCD2080H QCD3080H 90 QCD2090 QCD2090H QCD3090H 00 QCD2090 QCD2090H QCD300H QCD200 QCD200H 60 QCD2060NA 00 Carton Quantity Approximate Weight Lbs (kg) Dimensions 24 9.00 (4.) 2.50 x 7.50 x 5.00 (37.5 x 90.5 x 27.0) 2 2 9.00 (4.) 2.50 x 7.50 x 5.00 (37.5 x 90.5 x 27.0) 3 8 9.00 (4.) 2.50 x 7.50 x 5.00 (37.5 x 90.5 x 27.0) Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-23

. Industrial Circuit Breakers Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH Single-Pole Two-Pole Single-Pole Two-Pole QCR (Rear-Mounted Breakers) QCF (Front-Mounted Breakers) Contents Description Quick Reference............................. QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW........ Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF.............................. Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP....... Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW............................. Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH Product Selection........................ QCR and QCF Options and Accessories....... Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP......... Solenoid Operator Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers....... International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC... Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH Product Description Eaton Type QCR circuit Application Description QCR and QCF circuit breakers Features, Benefits and Functions breakers have as a standard are only /2-inch (2.7 mm) /2-inch (2.7 mm) wide feature provisions for 35 mm wide per pole and are per pole DIN rail rear mounting with excellent for general purpose Cable-in/cable-out a spring-loaded release. industrial applications where Black cases with black Optional clips for individual space savings is required. handles mounting are available as a separate accessory. Three position handle: Type QCF have two threaded steel inserts to facilitate front mounting with #6 32 steel screws. The clamp type terminals are accessible from the rear of the breaker so that cables can be accessed without removal of the breaker from the front cover. ON, Tripped (center), OFF Thermal-magnetic protection Page V4-T-2 V4-T-5 V4-T-8 V4-T- V4-T-4 V4-T-7 V4-T-20 V4-T-25 V4-T-27 V4-T-28 V4-T-3 V4-T-34 V4-T-37 V4-T-40 Standards and Certifications Built and listed to UL 489 UL File No. E789 CSA File No. LR48907 Type QCR and QCF circuit breakers are UL listed circuit breakers that are suitable for use as branch circuit protectors All ratings 5 60A are HACR rated V4-T-24 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. Product Selection Cable-In/Cable-Out, /2-Inch Wide QCR Breaker s 234 Continuous Ampere Rating at 40 C Single-Pole Two-Pole Two-Pole Three-Pole 20/240 Vac 20/240 Vac 240 Vac 5 QCR Breaker 0 kaic Interrupting Ratings 0 QCR00 QCR200 QCR00T QCR200T QCR200P 5 QCR05 6 QCR205 QCR205H QCR305H QCR05T 6 QCR205T QCR205HT QCR305HT QCR205P 20 QCR020 6 QCR2020 QCR2020H QCR3020H QCR020T 6 QCR2020T QCR2020HT QCR3020HT QCR2020P 25 QCR025 QCR2025 QCR2025H QCR3025H QCR025T QCR2025T QCR2025HT QCR3025HT QCR2025P 30 QCR030 QCR2030 QCR2030H QCR3030H QCR030T QCR2030T QCR2030HT QCR3030HT QCR2030P 35 QCR035 QCR2035 QCR2035P 40 QCR040 QCR2040 QCR2040P 45 QCR045 QCR2045 QCR2045P 50 QCR050 QCR2050 QCR2050P 55 QCR055 QCR2055 QCR2055P 60 7 QCR060 QCR2060 QCR2060P QCR Breaker 22 kaic Interrupting Ratings 5 QCRH05 6 QCRH205 QCRH05T 6 QCRH205T 20 QCRH020 6 QCRH2020 QCRH020T 6 QCRH2020T Notes Standard breaker terminals are box type lugs. 2 Breakers with T Suffix are suitable for line and load side ring terminal connection (#0 32 plus/minus terminal screw provided). 3 Breakers with P Suffix are suitable for terminating two 0 AWG Quick-Connect Type Terminals per phase on breaker load side. 4 Breakers with Shunt Trip (extra pole required on breaker right-hand side) are available on single-, two- and three-pole. Contact the Customer Support Center at -800-356-243. 5 Breakers with H Suffix have 240 Vac construction. 6 All 5 and 20A single-pole breakers are SWD (Switching Duty) rated for fluorescent lighting applications. 7 60/75 C Cu/Al wire on all ratings except 60A, which requires Cu only conductor. Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-25

. Industrial Circuit Breakers Cable-In/Cable-Out, /2-Inch Wide QCF Breaker s 23 Continuous Ampere Rating at 40 C Single-Pole Two-Pole Two-Pole Three-Pole 20/240 Vac 20/240 Vac 240 Vac 4 QCF Breaker 0 kaic Interrupting Ratings 0 QCF00 QCF200 QCF00T QCF200T 5 QCF05 5 QCF205 QCF205H QCF305H QCF05T 5 QCF205T QCF205HT QCF305HT 20 QCF020 5 QCF2020 QCF2020H QCF3020H QCF020T 5 QCF2020T QCF2020HT QCF3020HT 25 QCF025 QCF2025 QCF2025H QCF3025H QCF025T QCF2025T QCF2025HT QCF3025HT 30 QCF030 QCF2030 QCF2030H QCF3030H QCF030T QCF2030T QCF2030HT QCF3030HT 35 QCF035 QCF2035 40 QCF040 QCF2040 45 QCF045 QCF2045 50 QCF050 QCF2050 55 QCF055 QCF2055 60 6 QCF060 QCF2060 QCF Breaker 22 kaic Interrupting Ratings 5 QCFH05 5 QCFH205 QCFH05T 5 QCFH205T 20 QCFH020 5 QCFH2020 QCFH020T 5 QCFH2020T Notes Standard breaker terminals are box type lugs. 2 Breakers with T Suffix are suitable for line and load side ring terminal connection (#0 32 plus/minus terminal screw provided). 3 Breakers with Shunt Trip Attachment (extra pole required on breaker right-hand side) are available. Contact the Customer Support Center. 4 Breakers with H Suffix have 240 Vac construction. 5 All 5 and 20A single-pole breakers are SWD (Switching Duty) rated for fluorescent lighting applications. 6 60/75 C Cu/Al wire on all ratings except 60A, which requires Cu only conductor. V4-T-26 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. QCR and QCF Options and Accessories QCR and QCF Standard Box Terminals Factory-installed line and load side breaker terminal to accommodate4 AWG to 4 AWG wire. Standard Box Terminals QCR Quick-Connect Terminals Factory-installed two-prong quick-connect terminal on breaker load side suitable for terminating two 0 AWG wire with insulated slip-on terminals as shown. Line side terminal is the standard type. Suffix P Technical Data and Specifications Single-, two- and three-pole 0 kaic at 20/240 Vac, 0 60A 22 kaic at 20/240 Vac, 5 20A 0 kaic at 240 Vac, 0 30A QCR and QCF Ring or Spade Lug Terminals (0 to 30A Ratings Only) Factory-installed line and load side terminals each equipped with a #0 32 screw suitable for terminating one 0 AWG wire with insulated ring or spade type terminal as shown. Suffix T 3 kaic at 62.5 Vdc (single-pole) 3 kaic at 30 Vdc (two poles in series) Normal operating environment: 0 40 C 5 95% humidity (noncondensing) Available QCR and QCF Breaker Accessories Description Steel mounting clip mounts QCR breaker if individual mounting is required. Quantity two required for single- and twopole and four required for three-pole breakers. Removable padlock device for single-pole QCR or QCF breaker. Removable padlock device for multi-pole QCR or QCF breaker. Padlock bracket assembly for QCR or QCF single- or multi-pole breakers (OFF only). Padlock bracket for QCR, lock-off only. QCRMTGFT QCRFPLP QCRFPLMP QCRFLOFF QCRPLOFF Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-27

. Industrial Circuit Breakers QUICKLAG Type QCGF Single-Pole Ground Fault Circuit Breaker Contents Description Quick Reference............................. QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW........ Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF.............................. Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP....... Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW............................. Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH.............................. Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Product Selection........................ Wiring Diagram.......................... Dimensions............................. Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP......... Solenoid Operator Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers....... International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC... Page V4-T-2 V4-T-5 V4-T-8 V4-T- V4-T-4 V4-T-7 V4-T-20 V4-T-24 V4-T-29 V4-T-30 V4-T-30 V4-T-3 V4-T-34 V4-T-37 V4-T-40 Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Product Description Standards and Certifications QUICKLAG Ground Fault Circuit Breakers, Class A GFCI 5 ma trip sensitivity QUICKLAG Ground Fault Circuit Breakers, Class A GFCI Built and tested to UL 943 QUICKLAG Ground Fault Equipment Protectors 30 ma trip sensitivity QUICKLAG Ground Fault Equipment Protectors Built and tested to UL 053 V4-T-28 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. Product Selection QUICKLAG Type QCGF Single-Pole Ground Fault Circuit Breaker Breaker s Continuous Ampere Rating at 40 C Single-Pole Two-Pole 20 Vac 20/240 Vac Ground Fault Circuit Breakers 5 ma Sensitivity QUICKLAG Type: QCGF 0,000A Interrupting Capacity Thermal-Magnetic Breakers 5 QCGF05 QCGF205 20 QCGF020 QCGF2020 25 QCGF025 QCGF2025 30 QCGF030 QCGF2030 40 QCGF040 QCGF2040 50 QCGF2050 QUICKLAG Type: QCHGF 22,000A Interrupting Capacity Thermal-Magnetic Breakers 5 QCHGF05 QCHGF205 20 QCHGF020 QCHGF2020 25 QCHGF025 QCHGF2025 30 QCHGF030 QCHGF2030 Ground Fault Equipment Protectors 30 ma Sensitivity QUICKLAG Type: QCGFEP 0,000A Interrupting Capacity Thermal-Magnetic Breakers 5 QCGFEP05 QCGFEP205 20 QCGFEP020 QCGFEP2020 25 QCGFEP025 QCGFEP2025 30 QCGFEP030 QCGFEP2030 40 QCGFEP040 QCGFEP2040 50 QCGFEP2050 QUICKLAG Type: QCHGFEP 22,000A Interrupting Capacity Thermal-Magnetic Breakers 5 QCHGFEP05 QCHGFEP205 20 QCHGFEP020 QCHGFEP2020 25 QCHGFEP025 QCHGFEP2025 30 QCHGFEP030 QCHGFEP2030 Special Application Ground Fault Circuit Protector 5 ma Sensitivity QUICKLAG Type: QCGF 0,000A Interrupting Capacity with Bell Alarm (W) or Auxiliary Switch (W2) 5 QCGF05W QCGF205W 20 QCGF020W QCGF2020W 25 QCGF025W QCGF2025W 30 QCGF030W QCGF2030W 40 QCGF2040W 50 QCGF2050W 5 QCGF05W2 20 QCGF020W2 25 QCGF025W2 30 QCGF030W2 Special Application Ground Fault Equipment Protectors 30 ma Sensitivity QUICKLAG Type: QCGFEP 0,000A Interrupting Capacity with Bell Alarm (W) or Auxiliary Switch (W2) 5 QCGFEP05W QCGFEP205W 20 QCGFEP020W QCGFEP2020W 25 QCGFEP025W QCGFEP2025W 30 QCGFEP030W QCGFEP2030W 40 QCGFEP2040W 50 QCGFEP2050W 5 QCGFEP05W2 20 QCGFEP020W2 25 QCGFEP025W2 30 QCGFEP030W2 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-29

. Industrial Circuit Breakers Wiring Diagram Bell Alarm and Auxiliary Contact Schematic Ground Fault Breaker Dimensions Approximate Dimensions in Inches (mm) Shipping Data of Poles Blue Red Blue Wire Black Wire Red Wire Single-throw double-pole contacts are UL and CSA listed for 5A at 250 Vac. Bell Alarm (W) contacts change state when breaker trips. Auxiliary Switch (W2) contacts change state when breaker is opened (or tripped) or closed. 4-inch (355.6 mm) long 8 AWG pigtail wire leads provided. Carton Quantity NC NO Approximate Weight Lbs (kg) Dimensions 20.00 (5.0) 2.50 x 6.50 x 5.00 (37.5 x 65. x 27.0) 2 5 5.00 (2.3) 5.50 x 6.00 x 4.50 (393.7 x 52.4 x 4.3) V4-T-30 Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com

Industrial Circuit Breakers. BABRP and BABRSP Breakers Single- and Two-Pole Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP Product Description The BABRP and BABRSP are bolt-on branch circuit breakers designed for use in panelboards. The BRRP is a plug-on branch circuit breaker designed for use in loadcenters not manufactured with breakers with a -inch wide format and are listed on the Compatibility list for Classified Applications Pub. 2627. In addition to providing conventional branch circuit protection, they include a unique solenoid-operated mechanism that provides for efficient breaker pulse-on and pulse-off operation when used with a suitable controller like Eaton s Pow-R-Command lighting control system. These breakers can also be controlled by pushbutton or a PLC unit. Application Description Eaton s BABRP, BABRSP, BRRP and CLRP breakers are remotely operated molded case circuit breakers ideally suited for lighting control applications or energy management applications. Contents Description Quick Reference.............................. QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW QUICKLAG Plug-On Ground Fault and Equipment Protectors, Types QPGF, QPHGF, QPGFEP, QPHGFEP Bolt-On Types BAB, QBHW, HBAX, HBAW......... Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF............................... Bolt-On Ground Fault and Equipment Protectors, Types QBGF, QBHGF, QBGFEP, QBHGFEP........ Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW.............................. Cable-In/Cable-Out, /2-Inch Wide, Types QCR, QCF, QCRH, QCFH............................... Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Solenoid-Operated, Remote-Controlled Latching Types BABRP, BABRSP, BRRP and CLRP Product Selection........................ Technical Data and Specifications............ Wiring Diagrams......................... Solenoid Operator Remote Controlled Latching for Type GHBS, GBHS and GHQRSP Breakers........ International Rated Types HQP, BA, QC, GFMB, GFXBC Special Application Breakers, Types HQP, BA, QC.... Features, Benefits and Functions Bolt-on line-side terminal (BABRP, BABRSP Type BA) Plug-on line-side terminal (BRRP Type BR, CLRP Type CL) Cable connected load-side terminal Four-position control terminal Bi-metal assembly for thermal overload protection Fast-acting short-circuit protection Arc-chute assembly for fast-acting arc extinction Three-position handle: OFF, TRIP (Center), ON Page V4-T-2 V4-T-5 V4-T-8 V4-T- V4-T-4 V4-T-7 V4-T-20 V4-T-24 V4-T-28 V4-T-32 V4-T-33 V4-T-33 V4-T-34 V4-T-37 V4-T-40 Handle permits manual switching when control power is lost Mechanical trip indicator 5 and 20A breakers SWD (switching duty) rated HID ratings for HID (high intensity discharge) lighting All models HACR rated Status feedback of control circuit (BABRSP) Series rated (BABRP, BABRSP only) BRRP series rated same as BR breakers BABRP, BABRSP same as BA breakers Volume 4 Circuit Protection CA0800005E August 205 www.eaton.com V4-T-3