Dell PowerConnect 8024, 8024F, M8024, and M8024-k

Similar documents
Cisco Catalyst 3750X. Rapid EqualLogic Configuration Series Implementation Guide. Dell Storage Engineering April 2014

Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide

Dell EqualLogic Best Practices Series. Dell EqualLogic PS Series Reference Architecture for Cisco Catalyst 3750X Two-Switch SAN Reference

Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router iscsi Appliance

A Dell Technical White Paper Dell Storage Engineering

VOICE VLAN SUPPORT IN THE DELL POWERCONNECT 6200

Reference Architecture for Dell VIS Self-Service Creator and VMware vsphere 4

Link Aggregation Interoperability of the Dell PowerConnect 5316M with Cisco IOS or Cisco CatOS based Switches. By Bruce Holmes

Using MLAG in Dell Networks

Switch Web GUI Quick Configuration Guide for

A Whitepaper on. Building Data Centers with Dell MXL Blade Switch

Intel Active Management Technology with System Defense Feature Quick Start Guide

Dell DR4000 Disk Backup System. Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive

IP SAN Best Practices

Converged Networking Solution for Dell M-Series Blades. Spencer Wheelwright

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN

Performing Updates on a PowerEdge VRTX System Using CMC 1.0

Starting a Management Session

How To - Deploy Cyberoam in Gateway Mode

HP ProLiant Cluster for MSA1000 for Small Business Hardware Cabling Scheme Introduction Software and Hardware Requirements...

RACADM Command Line Reference Guide for idrac6 1.95, idrac6 3.5, and CMC 3.2

24 Port Gigabit Ethernet Web Smart Switch. Users Manual

AT-S84 Version ( ) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes

Switch Quick Configuration CLI Guide for

Deployment Guide: Transparent Mode

Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version Rev. B

AT-S60 Version Management Software for the AT-8400 Series Switch. Software Release Notes

A Principled Technologies white paper commissioned by Dell Inc.

Course. Contact us at: Information 1/8. Introducing Cisco Data Center Networking No. Days: 4. Course Code

HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios

How To Install An At-S100 (Geo) On A Network Card (Geoswitch)

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

IP SAN BEST PRACTICES

Read Me First for the HP ProCurve Routing Switch 9304M and Routing Switch 9308M

Building Microsoft Windows Server 2012 Clusters on the Dell PowerEdge VRTX

A Dell Technical White Paper Dell PowerConnect Team

SNMP-1 Configuration Guide

Alteon Basic Firewall Load Balancing. Sample Configuration

File Transfers. Contents

How Do I Upgrade Firmware and Save Configurations on PowerConnect Switches?

High Performance Tier Implementation Guideline

16-PORT POWER OVER ETHERNET WEB SMART SWITCH

Avalanche Site Edition

Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch. IGS-5225 Series. Quick Installation Guide

AT-S105 Version Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

EMC Data Domain Management Center

ProSAFE 8-Port and 16-Port Gigabit Click Switch

User Manual. EtherUSB

Half Bridge mode }These options are all found under Misc Configuration

N5 NETWORKING BEST PRACTICES

NMS300 Network Management System

Networking Solutions for Storage. Application Notes

Quick SAS Cabling Guide

Data Migration: Moving from Dell PowerVault MD3000i/MD3000 to MD3200i/MD3220i and MD3600i/MD3620i Series Storage Arrays

Dell EqualLogic Configuration Guide

ADMINISTRATION GUIDE Cisco Small Business

Liebert IntelliSlot Web Cards

Basic Router and Switch Instructions (Cisco Devices)

Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.

Abstract. Avaya Solution & Interoperability Test Lab

DELL. Unified Server Configurator Security Overview. A Dell Technical White Paper. By Raja Tamilarasan, Wayne Liles, Marshal Savage and Weijia Zhang

Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays

ProSafe Plus Switch Utility

ZyXEL AES-100 V2.03(AS.0) Release Notes/Manual Supplement

Network Detector Setup and Configuration

or later or later or later or later

Connecting to the Firewall Services Module and Managing the Configuration

AT-S95 Version AT-8000GS Layer 2 Stackable Gigabit Ethernet Switch Software Release Notes

Steps for Basic Configuration

NETFORT LANGUARDIAN INSTALLING LANGUARDIAN ON MICROSOFT HYPER V

NI InsightCM Server Version 1.0

AgGPS 542 Receiver: Enable GLONASS through the Web Browser

Release Notes. Contents. Release Purpose. Platform Compatibility. Licensing on the SRA Appliances and Virtual Appliance

AlliedWare Plus Version AT-9000 Layer 2-4 Gigabit Ethernet EcoSwitches Software Release Notes

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

File Transfers. Contents

DCICT: Introducing Cisco Data Center Technologies

LINK AGGREGATION INTEROPERABILITY OF THE DELL POWERCONNECT 6200 SERIES

Catalyst Layer 3 Switch for Wake On LAN Support Across VLANs Configuration Example

Software Update Manager User Guide

HUAWEI 9000 HD Video Endpoint V100R011. Security Maintenance. Issue 02. Date HUAWEI TECHNOLOGIES CO., LTD.

Layer 3 Network + Dedicated Internet Connectivity

Applies to: F1PG200ENau Belkin Analogue Telephone Adapter (ATA) Firmware release notes

System Overview and Terms

Can PowerConnect Switches Be Used in IP Multicast Networks?

DELL Remote Access Configuration Tool

Configuring Avaya 1120E, 1140E, 1220 and 1230 IP Deskphones with Avaya IP Office Release 6.1 Issue 1.0

Quick Start Guide. 500 Series Stackable Managed Switches

June 2013 v. 0.2

3.5 LAN HDD Enclosure User s Manual

Deploying Silver Peak VXOA Physical And Virtual Appliances with Dell EqualLogic Isolated iscsi SANs including Dell 3-2-1

FortiOS Handbook - Hardening your FortiGate VERSION 5.2.3

Abstract. Avaya Solution & Interoperability Test Lab

enetworks TM Using the Syslog Feature C.1 Configuring the Syslog Feature

Transcription:

Dell PowerConnect 8024, 8024F, M8024, and M8024-k Switch Configuration Guide for EqualLogic SANs Dell Storage Engineering October 2013 SISfeedback@Dell.com

Revisions Date October 2013 Description Initial release 2013 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell. Dell, the Dell logo, and the Dell badge, PowerConnect, EqualLogic, and Force10 are trademarks of Dell Inc. 2 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

Table of contents Revisions... 2 1 Introduction... 5 1.1 Audience... 5 1.2 Switch details... 5 2 Dell recommended switch configuration for 8024 and 8024F... 6 2.1 Cabling diagram for 8024 and 8024F... 6 2.2 Hardware configuration... 7 2.3 Check firmware version... 7 2.4 Delete startup configuration... 7 2.5 Disable DCB... 7 2.6 Configure out of band (OOB) management port... 8 2.7 Configure login credentials... 8 2.8 Configure Jumbo Frames... 8 2.9 Enable flow control... 8 2.10 Configure spanning tree portfast on edge ports... 8 2.11 Configure port channel for LAG... 9 2.12 Configure SFP+ ports for LAG... 9 2.13 Save configuration... 9 2.14 Configure additional switch... 9 3 Dell recommended switch configuration for M8024 and M8024-k... 10 3.1 Cabling diagram for M8024 and M8024-k... 10 3.2 Hardware configuration... 11 3.3 Check firmware version... 11 3.4 Delete startup configuration... 11 3.5 Check current operational mode... 12 3.6 Disable DCB... 12 3.7 Configure out of band (OOB) management port... 12 3.8 Configure login credentials... 12 3.9 Configure Jumbo Frames... 13 3.10 Enable flow control... 13 3.11 Configure spanning tree portfast on edge ports... 13 3 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

3.12 Configure port channel for LAG... 13 3.13 Configure SFP+ ports for LAG (M8024-k)... 13 3.14 Configure SFP+ ports for LAG (M8024)...14 3.15 Save configuration...14 3.16 Configure additional switch...14 4 Optional virtual stack configuration for 8024 and 8024F... 15 4.1 Check firmware version... 15 4.2 Delete startup configuration... 15 4.3 Configure virtual stack ports (switch 1)...16 4.4 Save configuration...16 4.5 Prepare the first switch for stack membership:...16 4.6 Configure virtual stack ports (switch 2)...16 4.7 Save configuration (switch 2)... 17 4.8 Final configuration... 17 4.9 Disable DCB... 17 4.10 Configure out of band (OOB) management port... 18 4.11 Configure login credentials... 18 4.12 Configure Jumbo Frames... 18 4.13 Configure spanning tree portfast on edge ports... 18 4.14 Enable flow control... 18 4.15 Save configuration...19 Additional resources... 20 4 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

1 Introduction This document shows how to configure Dell PowerConnect 8024, 8024F, M8024, and M8024-k switches for use with EqualLogic PS Series storage using Dell best practices. The recommended configuration uses link aggregation groups (LAGs) for inter-switch connections. An optional configuration is provided for 8024 and 8024F switches using the virtual stacking feature. For more information on EqualLogic SAN design recommendations, see the EqualLogic Configuration Guide at: http://en.community.dell.com/dellgroups/dtcmedia/m/mediagallery/19852516/download.aspx. 1.1 Audience This switch configuration guide describes an optimal configuration following Dell best practices for an EqualLogic iscsi SAN and is intended for storage or network administrators and deployment personnel. 1.2 Switch details The table below provides an overview of the switch configuration. Table 1 Switch specifications Dell PowerConnect 8024, 8024F, M8024, and M8024-k Switch vendor Dell PowerConnect Switch model PowerConnect 8024, PowerConnect 8024F, PowerConnect M8024, PowerConnect M8024-k Switch firmware 5.1.1.7 and later Note: For proper functionality, the switch must be at the switch firmware version shown in the table above before proceeding with this configuration. Using previous firmware versions may have unpredictable results. The latest firmware updates and documentation can be found at: support.dell.com. 5 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

2 Dell recommended switch configuration for 8024 and 8024F These steps show how to configure two PowerConnect 8024 or 8024F series switches with a LAG. The switches are interconnected using four 10 GbE Small Form-factor Pluggable (SFP+) ports, and the LAG is configured for Dynamic Link Aggregation Control Protocol (LACP). For configuring M8024 and M8024-k with a LAG, skip to Section 3. For configuring PowerConnect 8024 or 8024F series switches in a virtual stack configuration, skip to Section 4. 2.1 Cabling diagram for 8024 and 8024F The cabling diagram shown below represents the Dell recommend method for deploying your servers and EqualLogic arrays. Figure 1 Cabling diagram 6 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

2.2 Hardware configuration 1. Power on the two switches. 2. Connect a serial cable to the serial port of the first switch. 3. Using Putty or another terminal utility, open a serial connection session to the switch. 4. Open your terminal emulator and configure it to use the serial port (usually COM1, but this may vary depending on your system). Configure serial communications for 9600,N,8,1 and no flow control. 5. Connect the LAG cables between the switches. See this configuration in Figure 1. 2.3 Check firmware version console#show version Note: If the active version displayed here is not 5.1.1.7 or later, please visit support.dell.com and download the latest update for your switches. 2.4 Delete startup configuration Note: All configuration settings will be deleted. console#clear config console#copy running-config startup-config console#reload Are you sure you want to reload the stack? (y/n) y Note: The switch will reboot. 2.5 Disable DCB Note: The PowerConnect 8024 and 8024F switches do not support Enhanced Transmission Selection (ETS), therefore Data Center Bridging (DCB) must be manually disabled using the following steps: console#configure console(config)#no dcb enable 7 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

2.6 Configure out of band (OOB) management port console(config)#interface out-of-band console(config-if)#ip address ipaddress mask gateway console(config-if)#exit 2.7 Configure login credentials console(config)#line telnet console(config-telnet)#login authentication default console(config-telnet)#exit console(config)#ip http authentication local console(config)#username admin password yourpassword privilege 15 console(config)#enable password yourpassword 2.8 Configure Jumbo Frames console(config)#interface range tengigabitethernet all console(config-if)#mtu 9216 console(config-if)#exit 2.9 Enable flow control console(config)#flowcontrol This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to continue? (y/n)y 2.10 Configure spanning tree portfast on edge ports console(config)#interface range tengigabitethernet 1/0/1-20 console(config-if)#spanning-tree portfast console(config-if)#exit 8 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

2.11 Configure port channel for LAG These commands configure the switch interconnect as a LAG. console(conf)#interface Port-channel 1 console(conf-if-po1)#mtu 9216 console(conf-if-po1)#exit 2.12 Configure SFP+ ports for LAG These commands assign four 10Gb SFP+ ports to the Port Channel. console(conf)#interface range Tengigabitethernet 1/0/21-24 console(conf-if)#channel-group 1 mode active console(conf-if)#exit console(conf)#exit 2.13 Save configuration console#copy running-config startup-config This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n)y 2.14 Configure additional switch Repeat the commands from section 2 to configure the second switch. Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in a non-default VLAN, refer to the documentation for your switch. 9 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

3 Dell recommended switch configuration for M8024 and M8024-k These steps show you how to configure two PowerConnect M8024 or M8024-k series switches with a LAG. The switches are interconnected using four 10 GbE Small Form-factor Pluggable (SFP+) ports, and the LAG is configured for Dynamic Link Aggregation Control Protocol (LACP). 3.1 Cabling diagram for M8024 and M8024-k The cabling diagram shown below represents the Dell recommend method for deploying your servers and EqualLogic arrays. Figure 2 Cabling diagram 10 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

3.2 Hardware configuration 1. Ensure the blade chassis and switch modules are powered on. 2. Connect a serial cable to the serial port of the first switch or optionally use the Chassis Management Controller (CMC) to connect to the switch module. 3. Using Putty or another terminal utility, open a serial connection session to the switch. 4. Open your terminal emulator and configure it to use the serial port (usually COM1, but this may vary depending on your system). Configure serial communications for 9600,N,8,1 and no flow control. 5. Connect the LAG cables between the switches. See this configuration in Figure 2. 3.3 Check firmware version console#show version Note: If the active version displayed here is not 5.1.1.7 or later, please visit support.dell.com and download the latest update for your switches. 3.4 Delete startup configuration Note: All configuration settings will be deleted console#clear config console#copy running-config startup-config console#reload Are you sure you want to reload the stack? (y/n) y Note: The switch will reboot. 11 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

3.5 Check current operational mode Note: Before proceeding, the System Operational Mode must be set to Normal. Some switches, such as the M8024k, ship from the factory in simple mode. console#configure console(config)#no mode simple Switching modes will immediately clear the configuration. Are you sure you want to continue? (y/n) y Switch has unsaved changes. Are you sure you want to continue? (y/n) y Note: The switch will reboot. If the switch reports Normal mode already active, then you may proceed to the next step without rebooting. 3.6 Disable DCB Note: The PowerConnect M8024-k switches do not support Enhanced Transmission Selection (ETS), therefore Data Center Bridging (DCB) must be manually disabled using the following steps. If you have the M8024 switch, skip this section. console#configure console(config)#no dcb enable 3.7 Configure out of band (OOB) management port console(config)#interface out-of-band console(config-if)#ip address ipaddress mask gateway console(config-if)#exit 3.8 Configure login credentials console(config)#line telnet console(config-telnet)#login authentication default console(config-telnet)#exit 12 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

console(config)#ip http authentication local console(config)#username admin password yourpassword privilege 15 console(config)#enable password yourpassword 3.9 Configure Jumbo Frames console(config)#interface range tengigabitethernet all console(config-if)#mtu 9216 console(config-if)#exit 3.10 Enable flow control console(config)#flowcontrol This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to continue? (y/n)y 3.11 Configure spanning tree portfast on edge ports console(config)#interface range tengigabitethernet 1/0/1-16 console(config-if)#spanning-tree portfast console(config-if)#exit 3.12 Configure port channel for LAG These commands configure the switch interconnect as a LAG. console(conf)#interface port-channel 1 console(conf-if-po1)#mtu 9216 console(conf-if-po1)#exit 3.13 Configure SFP+ ports for LAG (M8024-k) Note: The commands in this section assign the four built-in external 10Gb SFP+ ports to the Port Channel on the M8024-k. If you have the M8024 switch, skip this step and proceed to Section 3.14. console(conf)#interface range tengigabitethernet 1/0/17-20 13 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

console(conf-if)#channel-group 1 mode active console(conf-if)#exit console(conf)#exit 3.14 Configure SFP+ ports for LAG (M8024) Note: The commands in this section assign four 10Gb SFP+ ports from an optional expansion module in the first expansion slot, to the Port Channel. If you have the M8024-k switch, see section 3.13 instead. console(conf)#interface range tengigabitethernet 1/1/1-4 console(conf-if)#channel-group 1 mode active console(conf-if)#exit console(conf)#exit 3.15 Save configuration console#copy running-config startup-config This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n)y 3.16 Configure additional switch Repeat the commands from section 3 to configure the second switch. Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in a non-default VLAN, refer to the documentation for your switch. 14 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

4 Optional virtual stack configuration for 8024 and 8024F Note: If you wish to use a virtual stack configuration instead of LAG, follow the instruction below instead of section 2 or 3. One advantage of stacked switches is that they can be managed as a single switch; however firmware updates will update all members of the stack simultaneously and therefore should only be done during planned downtime. Do not connect the cables between the stacked switches (this will be done in a later step). On both switches, enter the following commands: 4.1 Check firmware version console#show version Note: If the active version displayed is not 5.1.1.7 or later, please visit support.dell.com and download the latest update for your switches. 4.2 Delete startup configuration Note: All configuration settings will be deleted console#clear config console#copy running-config startup-config console#reload Are you sure you want to reload the stack? (y/n) y Note: The switch will reboot. On the first switch only, proceed with the following steps: 15 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

4.3 Configure virtual stack ports (switch 1) console(config)#stack console(config-stack)#stack-port tengigabitethernet 1/0/21 stack console(config-stack)#stack-port tengigabitethernet 1/0/22 stack console(config-stack)#stack-port tengigabitethernet 1/0/23 stack console(config-stack)#stack-port tengigabitethernet 1/0/24 stack console(config-stack)#exit console(config)#exit 4.4 Save configuration console#copy running-config startup-config This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n)y 4.5 Prepare the first switch for stack membership: (Provide the enable password you set previously) console#config console(config)#stack console(config-stack)#member 2 2 console(config-stack)#exit console(config)#exit console#copy running-config startup-config 4.6 Configure virtual stack ports (switch 2) On the second switch only, enter the following: console#configure console(config)#switch 1 renumber 2 All the switches in the stack will be reset to perform Manager unit renumbering and the configuration of Manager switch interfaces will be cleared. Are you sure you want to renumber? (y/n)y 16 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

Note: the switch will reboot. console#configure console(config)#stack console(config-stack)#stack-port tengigabitethernet 2/0/21 stack console(config-stack)#stack-port tengigabitethernet 2/0/22 stack console(config-stack)#stack-port tengigabitethernet 2/0/23 stack console(config-stack)#stack-port tengigabitethernet 2/0/24 stack console(config-stack)#exit console(config)#exit 4.7 Save configuration (switch 2) console#copy running-config startup-config This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n)y 4.8 Final configuration Power off switch 2, and then connect the cables between the stacked switches (ports 21-24). Power on switch 2 and wait until it has fully booted. From the first switch (master) complete the configuration for the stack: console#show switch Note: Before proceeding ensure that the status for all switches in the stack show OK. 4.9 Disable DCB Note: The PowerConnect 8024 and 8024F switches do not support Enhanced Transmission Selection (ETS), therefore Data Center Bridging (DCB) must be manually disabled using the following steps: console#configure console(config)#no dcb enable 17 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

4.10 Configure out of band (OOB) management port console(config)#interface out-of-band console(config-if)#ip address ipaddress mask gateway console(config-if)#exit 4.11 Configure login credentials console(config)#line telnet console(config-telnet)#login authentication default console(config-telnet)#exit console(config)#ip http authentication local console(config)#username admin password yourpassword privilege 15 console(config)#enable password yourpassword 4.12 Configure Jumbo Frames console(config)#interface range tengigabitethernet all console(config-if)#mtu 9216 4.13 Configure spanning tree portfast on edge ports console(config-if)#spanning-tree portfast console(config-if)#exit 4.14 Enable flow control console(config)#flowcontrol This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to continue? (y/n)y console(config)#exit 18 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

4.15 Save configuration console#copy running-config startup-config This operation may take a few minutes. Management interfaces will not be available during this time. 19 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

Additional resources Support.dell.com is focused on meeting your needs with proven services and support. DellTechCenter.com is an IT Community where you can connect with Dell Customers and Dell employees for the purpose of sharing knowledge, best practices, and information about Dell products and your installations. Referenced or recommended Dell publications: Dell EqualLogic Configuration Guide: http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/19852516/download.aspx Dell EqualLogic Compatibility Matrix: http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/19856862/download.aspx For EqualLogic best practices white papers, reference architectures, and sizing guidelines for enterprise applications and SANs, refer to Storage Infrastructure and Solutions Team Publications at: http://dell.to/sm4hjt 20 SCG1008 PowerConnect 8024, 8024F, M8024 and M8024-k Switch Configuration Guide for EqualLogic SANs

This white paper is for informational purposes only. The content is provided as is, without express or implied warranties of any kind.