Building Microsoft Windows Server 2012 Clusters on the Dell PowerEdge VRTX
|
|
|
- Morgan Hunt
- 10 years ago
- Views:
Transcription
1 Building Microsoft Windows Server 2012 Clusters on the Dell PowerEdge VRTX Startup Guide Paul Marquardt
2 Contents Introduction... 4 Requirements... 4 Chassis setup... 6 Chassis placement and CMC cabling... 6 LCD chassis setup and configuration... 6 I/O module network cabling and mappings... 7 Windows installation and configuration on VRTX supported server node(s)... 9 Basic OS installation steps... 9 Role configuration and feature enablement... 9 Role and feature configuration steps Required registry entries Storage configuration Creating virtual disks Creating a virtual disk for quorum use Creating a virtual disk for CSV use Setting assignment mode Assigning virtual disks Installing the shared PERC8 driver Offline Shared Disk Configuration Steps Shared Storage Configuration Steps Changing the computer name and domain membership Cluster validation and creation Validating clusters Creating clusters Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 2
3 Tables Table 1. Software requirements... 4 Table 2. Hardware requirements... 5 Table 3. Cluster requirements... 5 Table 4. VRTX IOM pass-through IOM port to slot mappings... 7 Table 5. Registry entries Figures Figure 1. CMC and serial ports... 6 Figure 2. VRTX IOM pass-through module port locations and associated slot mappings... 7 Figure 3. VRTX IOM switch module external port listing... 8 This document is for informational purposes only and may contain typographical errors and technical inaccuracies. The content is provided as is, without express or implied warranties of any kind Dell Inc. All rights reserved. Dell and its affiliates cannot be responsible for errors or omissions in typography or photography. Dell, the Dell logo, and PowerEdge are trademarks of Dell Inc. Intel and Xeon are registered trademarks of Intel Corporation in the U.S. and other countries. Microsoft, Windows, and Windows Server are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and names of others. June 2013 Version 1.0 Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 3
4 Introduction This guide provides instructions on how to configure the Dell PowerEdge VRTX chassis with Microsoft Windows Server 2012 in a supported failover cluster environment. These instructions cover configuration and installation information for: Chassis-shared storage and networking Failover clustering Hyper-V Cluster Shared Volumes (CSV) Specialized requirements for Windows Server 2012 to function correctly with the VRTX chassis Requirements Table 1, 0, and Table 3 list the software requirements hardware requirements, and networking requirements for proper configuration of the VRTX chassis, server node(s), and operating system (OS).. Table 1. Software requirements Software Use Location Current SPERC8 Driver Current M620 Drivers Current M520 Drivers Administrator password DHCP Server or Static IP addresses Operating System media VRTX Firmware Required for shared disk connectivity. Required for optimal operating system performance. Required for optimal operating system performance. Used for all Microsoft Windows installation methods. Server Network Interface Card network connectivity. Required for operating system installation. Required for optimal system and operating system performance. oting/us/en/555/product/poweredgem620 oting/us/en/555/product/poweredgem520 Contact your local system administrator. Contact your local system administrator. OEM availability with purchase or selfprovided. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 4
5 Table 2. Hardware requirements Hardware Ethernet Network cable for the chassis CMC Ethernet Network cables for each of the blade NICs Table 3. Cluster name DHCP Server or Static IP addresses SPERC8 Shared Disk Active Directory Domain Membership Domain Administrator Account Cluster requirements Cluster resource Cluster IP Resource, Cluster Heartbeat Resource Quorum Shared Disk Resource, Cluster Shared Volume Resource Active Directory Domain Controller Active Directory membership Note: Update all firmware for the Chassis Management Controller (CMC), mainboard, idrac7, I/O module, Shared PERC8, expander, and physical disks before completing any additional steps. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 5
6 Chassis setup This section provides information on proper chassis location, as well as instructions on setting up the chassis using the LCD display and cabling the CMC and VRTX IOM network modules. This information includes the port mappings for the VRTX I/O Module (IOM) pass-through module to their corresponding blade slots and VRTX IOM switch module port listings. Chassis placement and CMC cabling 1. Place the chassis in an appropriate location with proper ventilation, and access to the rear of the chassis and the appropriate electrical receptacles. 2. Verify all power supplies are properly installed in the chassis and plugged into an appropriate electrical source. 3. Connect an Ethernet cable to the top CMC port on the rear of the chassis. The port is located just above the serial port as shown in Figure 1. Figure 1. CMC and serial ports 4. Insert server node(s) into the slots provided in the chassis. LCD chassis setup and configuration 1. Press the power button on the front of the chassis just above the KVM and USB ports to power the chassis on. 2. Press the round center button on the top of the front of the chassis for the LCD display. 3. Follow the prompts to configure the LCD display for the appropriate language and IP configuration for the chassis. This will include either a DHCP provided IP address for the CMC and blade idracs, or you can specify a static IP for each. Make note of the IP address given to the CMC, which is needed for the next configuration section. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 6
7 I/O module network cabling and mappings Configure your chassis networking; for a VRTX IOM pass-through module, use Step 1, or if you are using the VRTX IOM switching I/O module, use Step VRTX IOM pass-through module: Connect an Ethernet cable to each port associated with the server node(s) installed in the system. Refer to Table 1 for port mapping relationships, and Figure 2 for port locations and mappings. Table 4. VRTX IOM pass-through IOM port to slot mappings Port Number Associated Slot Port 1 Slot 1 Port 2 Slot 1 Port 3 Slot 2 Port 4 Slot 2 Port 5 Slot 3 Port 6 Slot 3 Port 7 Slot 4 Port 8 Slot 4 Figure 2. VRTX IOM pass-through module port locations and associated slot mappings Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 7
8 2. VRTX IOM switch module: Connect at least one Ethernet cable to the I/O module. Refer to Figure 3 for more details on the external port listings. Note: For additional port listings or switch configuration refer to the I/O module Getting Started Guide and the I/O module GUI available by selecting Launch I/O Module GUI from the I/O Module Overview submenu. Figure 3. VRTX IOM switch module external port listing Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 8
9 Windows installation and configuration on VRTX supported server node(s) This section provides an overview of the OS installation process using bootable optical media. Following the OS installation instructions are steps for configuring the OS roles and features. Steps are provided for the SPERC driver installation and required registry entries. Steps are also provided for validation and creation of failover clustering. Microsoft Windows Server 2008 R2 and 2012 are both supported failover clustering platforms on the VRTX chassis. For a detailed description of the installation of the OS using the Dell Systems Management Tools and Documentation or your own OS media, refer to the Microsoft Windows Server 2012 For Dell PowerEdge Systems Installation Instructions and Important Information guide on Dell.com/Support/Manuals. Basic OS installation steps 1. Configure the system to boot from optical media. 2. Insert the bootable Microsoft Windows Server 2012 installation disk into the optical drive in the chassis or USB port on the blade server. 3. Insert the USB device with the OS drivers located in the $WinPEdriver$ folder For A-rev, shouldn t we tell them to use LC? 4. Power on the blade server. 5. Follow the prompts to boot from optical media, and the prompts to install the OS on the local disk located in the blade. 6. Enter the product key if required. 7. Follow the prompts to complete the Windows Server installation. 8. Enter the administrator password and login in Windows Server. Role configuration and feature enablement This section provides instructions for enabling the Hyper-V role and failover cluster feature enablement in Windows Server. These steps for role configuration and feature enablement can be combined to eliminate the need for two separate operations. Note: These roles and features must be enabled on every server node(s) that will be configured as part of the failover cluster. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 9
10 Role and feature configuration steps 1. Open Server Manager. 2. Select Add roles and features from the Manage menu to start the Add Roles and Features Wizard. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 10
11 3. Select Next on the Before you begin screen. 4. On the Select installation type screen, select the Role-based or feature-based installation radio button, then select Next. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 11
12 5. Select the local server from the Server Pool list on the Select destination server screen. 6. Click Next. 7. On the Select server roles screen, select the checkbox next to Hyper-V. 8. Click Next. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 12
13 9. Verify the Include management tools (if applicable) checkbox is checked on the Add features that are required for Hyper-V screen. 10. Click Add Features. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 13
14 11. On the Select features screen, select the checkbox next to Failover Clustering. 12. Click Next. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 14
15 13. Verify the Include management tools (if applicable) checkbox is checked on the Add features that are required for Hyper-V screen. 14. Click Add Features. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 15
16 15. Check the checkbox labeled Restart the destination server automatically if required. 16. Click Install to complete the installation of the Hyper-V role. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 16
17 Required registry entries The following registry entries are required on each node of the cluster to enable them to see the drives on the shared PERC8. Table 5. Registry entries Location Entry type Property HKLM\SYSTEM\CurrentControlSet\Services\ClusDisk\Parameters DWORD AllowBusTypeRAID 0X01 Value 1. Open the registry using the run prompt. 2. Type REGEDIT and press Enter. 3. Navigate to HKey_Local_Machine\SYSTEM\CurrentControlSet\Services\ClusDisk\Parameters. 4. Right-click in the right pane and from the context menu select New > DWORD (32bit) Value. 5. Type AllowBusTypeRAID in the Name field and press Enter. 6. Right-click the new entry and select Modify. 7. In the Value Data field, type 1 and press Enter. 8. Close the REGEDIT window. For additional information regarding this registry change, refer to Microsoft KB , or find it here. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 17
18 Storage configuration This section describes the process for creating virtual disks available through the shared PERC8, and assigning the disks to the corresponding server node(s). These are the shared disks used in the installation of failover clustering. Virtual disks are required for the operating system to pass the validation steps of the cluster creation steps in the Cluster validation and creation section of this guide. Creating virtual disks This example creates two disks for cluster use, meeting the minimum of two virtual disks required to create a Hyper-V cluster. One disk is used for the cluster-shared disk quorum and the second disk is used as the Cluster Shared Volume (CSV) in the Hyper-V cluster configuration (see the section titled: Creating a virtual disk for CSV use). This guide creates a single RAID 1 virtual disk for the cluster-shared quorum drive and a single RAID 10 virtual disk for the CSV; however you may use the RAID level appropriate for your environment. Creating a virtual disk for quorum use 1. Expand Chassis Overview > Storage on the Chassis Management Controller web interface. 2. Select the Storage submenu. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 18
19 3. Select Controllers under Storage and verify that the property labeled Rollup Status listed has the value OK. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 19
20 4. Select Physical Disks and verify that all physical disks are accounted for in the chassis shared disk enclosure, and that each disk has a State of either Online or Ready. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 20
21 5. Select Virtual Disks, and select Create from the top menu. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 21
22 6. On the Create Virtual Disk page, enter QUORUM in the Name field. 7. Select RAID 1 from the RAID Level drop-down menu. Be sure to check the capacity limits as listed in the Select Physical Disks table. Leave the default values for all properties. 8. Select Physical Disk 0:0:0 and Physical Disk 0:0:1 from the Internal Disks table by checking the associated check box. 9. Click Create Virtual Disk. 10. Click OK on the message stating Operation Successful. 11. The Quorum virtual disk setup is complete. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 22
23 Creating a virtual disk for CSV use 1. Select Create from the top menu. 2. On the Create Virtual Disk page, enter CSV in the Name field. 3. Select RAID 10 from the RAID Level drop-down menu. Be sure to check the capacity limits listed in the Select Physical Disks table. Leave the default values for all properties. 4. Select Physical Disk 0:0:2, Physical Disk 0:0:3, Physical Disk 0:0:4, Physical Disk 0:0:5 from the Internal Disks table by checking the associated check box. 5. Click Create Virtual Disk. 6. Click OK on the message stating Operation Successful. 7. The Cluster Shared Volume virtual disk setup is complete. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 23
24 Setting assignment mode Virtual disks can be assigned from one server slot to another by mapping the virtual adapter. For the example used in this guide, the assignment mode should be set to Multiple Assignment. By default, virtual disks are set to Single Assignment. 1. Select Storage on the left pane. 2. Select Setup from the top menu. 3. After the page populates, scroll to the bottom of the page and select the Multiple Assignment radio button. 4. Click Apply. IMPORTANT!: Multiple assignments should only be used with Microsoft Failover Clustering scenarios. Do not use this mode unless the servers have Cluster Services installed on them. Use of this mode without Cluster Services may lead to corrupted or lost data. Verify the disks are offline on all servers before beginning the cluster installation procedure. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 24
25 Assigning virtual disks 1. Select Virtual Disks under Storage. 2. Select Assign from the top menu. 3. In the Assign Virtual Disks table, select Full Access from the drop-down menus provided for all populated virtual adapters assigned to the row labeled Quorum. 4. In the Assign Virtual Disk table, select Full Access from the drop-down menus provided for all populated virtual adapters assigned to the row labeled DataDisk. 5. Click Apply. 6. Assigning virtual disk this may take several seconds. 7. Click OK to dismiss the message stating Successfully assigned all Virtual Disks. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 25
26 Installing the shared PERC8 driver This section describes how to manually install the shared PERC8 driver for Windows Server Have your device driver available on removable media or a network location prior to completing these steps. REQUIREMENT: The shared PERC8 driver must be the same version on each node of the cluster. 1. Open the Server Manager window and select Computer Management from the Tools menu. 2. Select Device Manager. 3. Right-click the Storage Controller with the yellow bang, and select Update Driver Software from the context menu. 4. Follow the instructions in the Update Driver Software wizard. 5. Click OK on the Shared PERC 8 Properties window. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 26
27 Offline Shared Disk Configuration Steps 1. Open the Server Manager window and select Computer Management from the Tools menu. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 27
28 2. Select Disk Management. It may take a few seconds to populate the disk information in the right pane. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 28
29 3. Right-click Disk 1 and select Offline. 4. Repeat Step 3 for Disk Repeat Steps 1 to 4 on all servers which have assigned shared storage. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 29
30 Shared Storage Configuration Steps 6. Open the Server Manager window and select Computer Management from the Tools menu. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 30
31 7. Select Disk Management. It may take a few seconds to populate the disk information in the right pane. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 31
32 8. Right-click Disk 1 and select Online. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 32
33 9. Repeat Step 3 for Disk Right-click Disk 1 and select Initialize. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 33
34 11. Verify both checkmarks are selected and MBR is selected on the Initialize Disk window. 12. Select OK to initialize the disks. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 34
35 13. Right-click the Unallocated space and select New Simple Volume. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 35
36 14. Click Next to start the New Simple Volume Wizard. 15. Click Next to accept the default entry. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 36
37 16. Select Q from the drop-down menu and click Next. 17. Enter Quorum in the Volume label field and click Next. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 37
38 18. Click Finish to complete the process. 19. Repeat steps 7-12 for Disk 2. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 38
39 Changing the computer name and domain membership 1. Open the Server Manager window. 2. Select Local Server. 3. Select the Computer name in the Properties section. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 39
40 4. Click Change in the System Properties window. 5. In the Computer name field enter the new name, such as VRTX-N1. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 40
41 6. Select the Domain radio button and type the name of the domain, such as OSELab.local. 7. Click OK. 8. Click OK. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 41
42 9. Enter domain admin credentials to join the system to the domain, and click OK. 10. Click OK. 17. Click Restart Now to reboot the system and complete the process. 11. Repeat this process for all blade servers in the cluster, giving each server node a unique name. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 42
43 Cluster validation and creation This section describes the steps to complete cluster validation and cluster creation. The validation process finds hardware or configuration issues before a failover cluster can go into production. The cluster validation wizard determines if the current hardware and software configuration meets the supported configuration guidelines. Validating clusters 1. To open the Failover Cluster Manager, open the Server Manager window, and select Failover Cluster Manager from the Tools menu. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 43
44 2. To open the Cluster Validation Wizard, in Failover Cluster Manager window, select Validate Configuration from the Actions menu. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 44
45 3. Select Next to start the Validate a Configuration Wizard. 4. Enter the names of the servers to add to the cluster in the Enter Name field, separated by a comma. 5. Click Add. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 45
46 6. Click Next. 7. Verify the Run all test (recommended) radio button is selected. 8. Click Next. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 46
47 9. After all fields are populated on the Confirmation window, select Next. 10. You will see the progress bar as the validation process gathers information for the report. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 47
48 11. In the validation summary, verify that each node tested shows as Validated. If a node does not show as validated, click View Report to open the report and review the issue(s) for each node not validated. 12. Once all failures are fixed, rerun the validation wizard and click Finish to begin the cluster creation. Note: You may see some warnings in the validation report. Check to be sure all shared disks are validated. If you see disk warnings, verify these are not local disks in the server(s) that have been listed. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 48
49 Creating clusters 1. Click Next to start the Create Cluster Wizard. 2. Enter a name for the cluster, such as CLUS1-VRTX, in the Cluster Name field. 3. Click Next. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 49
50 4. Click Next. 5. You will see the progress bar while the cluster is created. Once the cluster service starts on all nodes, the Summary window opens. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 50
51 6. Verify the information is correct on the Summary screen. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 51
52 Once cluster creation is complete, the Failover Cluster Manager window lists all of the resources. Building Microsoft Windows 2012 Clusters on the Dell PowerEdge VRTX 52
A Principled Technologies deployment guide commissioned by Dell Inc.
A Principled Technologies deployment guide commissioned by Dell Inc. TABLE OF CONTENTS Table of contents... 2 Introduction... 3 About the components... 3 About the Dell PowerEdge VRTX...3 About the Dell
StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013
StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013 TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind Software logos are trademarks
Lifecycle Controller Platform Update/Firmware Update in Dell PowerEdge 12th Generation Servers
Lifecycle Controller Platform Update/Firmware Update in Dell PowerEdge 12th Generation Servers This Dell Technical White Paper provides detailed information about the capabilities of Lifecycle Controller
StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013
StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013 TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind Software
Manage Dell Hardware in a Virtual Environment Using OpenManage Integration for VMware vcenter
Manage Dell Hardware in a Virtual Environment Using OpenManage Integration for VMware vcenter This Dell Technical White Paper gives an overview of using OpenManage Integration to streamline the time, tools
Dell Compellent Storage Center
Dell Compellent Storage Center How to Setup a Microsoft Windows Server 2012 Failover Cluster Reference Guide Dell Compellent Technical Solutions Group January 2013 THIS BEST PRACTICES GUIDE IS FOR INFORMATIONAL
Nexio Connectus with Nexio G-Scribe
Nexio Connectus with Nexio G-Scribe 2.1.2 3/20/2014 Edition: A 2.1.2 Publication Information 2014 Imagine Communications. Proprietary and Confidential. Imagine Communications considers this document and
Drobo How-To Guide. Topics. What You Will Need. Prerequisites. Deploy Drobo B1200i with Microsoft Hyper-V Clustering
Multipathing I/O (MPIO) enables the use of multiple iscsi ports on a Drobo SAN to provide fault tolerance. MPIO can also boost performance of an application by load balancing traffic across multiple ports.
Integrating idrac7 With Microsoft Active Directory
Integrating idrac7 With Microsoft Active Directory Whitepaper Author: Jim Slaughter This document is for informational purposes only and may contain typographical errors and technical inaccuracies. The
Load Balancing. Outlook Web Access. Web Mail Using Equalizer
Load Balancing Outlook Web Access Web Mail Using Equalizer Copyright 2009 Coyote Point Systems, Inc. Printed in the USA. Publication Date: January 2009 Equalizer is a trademark of Coyote Point Systems
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Release 3.0 User Guide P/N 300-999-671 REV 02 Copyright 2007-2013 EMC Corporation. All rights reserved. Published in the USA.
How To Set Up A Two Node Hyperv Cluster With Failover Clustering And Cluster Shared Volume (Csv) Enabled
Getting Started with Hyper-V and the Scale Computing Cluster Scale Computing 5225 Exploration Drive Indianapolis, IN, 46241 Contents Contents CHAPTER 1 Introduction to Hyper-V: BEFORE YOU START. vii Revision
Remote Installation of VMware ESX Server Software Using Dell Remote Access Controller
Remote Installation of VMware ESX Server Software Using Dell Remote Access Controller October 2005 Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use
Evaluation of Dell PowerEdge VRTX Shared PERC8 in Failover Scenario
Evaluation of Dell PowerEdge VRTX Shared PERC8 in Failover Scenario Evaluation report prepared under contract with Dell Introduction Dell introduced its PowerEdge VRTX integrated IT solution for remote-office
Integrating idrac 7 with Microsoft Active Directory
Integrating idrac 7 with Microsoft Active Directory Whitepaper Author: Jim Slaughter This document is for informational purposes only and may contain typographical errors and technical inaccuracies. The
Discovery and Inventory of Dell Devices using OpenManage Essentials
Discovery and Inventory of Dell Devices using OpenManage Essentials R Rajiv Nair Ashish Suyal Dell Product Group Enterprise This document is for informational purposes only and may contain typographical
EMC ViPR Controller Add-in for Microsoft System Center Virtual Machine Manager
EMC ViPR Controller Add-in for Microsoft System Center Virtual Machine Manager Version 2.3 Installation and Configuration Guide 302-002-080 01 Copyright 2013-2015 EMC Corporation. All rights reserved.
Secure Perfect RAID Recovery Instructions
Secure Perfect RAID Recovery Instructions Contents Overview Dell PowerEdge 2500 RAID Level 1 Recovery Instructions Overview NOTE If you possess a previous version of this document, you may notice changes
HP ProLiant DL380 G5 High Availability Storage Server
HP ProLiant DL380 G5 High Availability Storage Server installation instructions *5697-7748* Part number: 5697 7748 First edition: November 2008 Legal and notice information Copyright 1999, 2008 Hewlett-Packard
StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster
#1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with MARCH 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the
WINDOWS SERVER 2008 OFFLINE SYSTEM RECOVERY USING WINDOWS SERVER BACKUP WITH NETWORKER
TECHNICAL NOTES WINDOWS SERVER 2008 OFFLINE SYSTEM RECOVERY USING WINDOWS SERVER BACKUP WITH NETWORKER NETWORKER RELEASE 7.4 SERVICE PACK 2 AND LATER TECHNICAL NOTE P/N 300-010-339 REV A02 Table of Contents
Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center
Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center Dell Compellent Solution Guide Kris Piepho, Microsoft Product Specialist October, 2013 Revisions Date Description 1/4/2013
Dell Server Management Pack Suite Version 6.0 for Microsoft System Center Operations Manager User's Guide
Dell Server Management Pack Suite Version 6.0 for Microsoft System Center Operations Manager User's Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make
StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012
StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012 TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind Software logos are trademarks of StarWind Software which
Dell DR4000 Disk Backup System. Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive
Dell DR4000 Disk Backup System Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive Storage Engineering Dell Product Group February 2012 THIS
How to Setup and Configure ESXi 5.0 and ESXi 5.1 for OpenManage Essentials
How to Setup and Configure ESXi 5.0 and ESXi 5.1 for OpenManage Essentials This Dell technical white paper provides step-by-step instructions to set up and configure ESXi for OpenManage Essentials. BBenjamin
Using Cisco UC320W with Windows Small Business Server
Using Cisco UC320W with Windows Small Business Server This application note explains how to deploy the Cisco UC320W in a Windows Small Business Server environment. Contents This document includes the following
Deploying Remote Desktop Connection Broker with High Availability Step-by-Step Guide
Deploying Remote Desktop Connection Broker with High Availability Step-by-Step Guide Microsoft Corporation Published: May 2010 Abstract This guide describes the steps for configuring Remote Desktop Connection
Introduction to Hyper-V High- Availability with Failover Clustering
Introduction to Hyper-V High- Availability with Failover Clustering Lab Guide This lab is for anyone who wants to learn about Windows Server 2012 R2 Failover Clustering, focusing on configuration for Hyper-V
Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide
Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide Windows 2000, Windows Server 2003 5.0 11293743 Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide Copyright
Microsoft SQL Server 2014. Installation Guide
Microsoft SQL Server 2014 Installation Guide Notices 2015 XMPie Inc. All rights reserved. U.S. Patents 6948115, 7406194, 7548338, 7757169 and pending patents. JP Patent 4406364B and pending patents. Microsoft
Operating System Installation Guide
Operating System Installation Guide This guide provides instructions on the following: Installing the Windows Server 2008 operating systems on page 1 Installing the Windows Small Business Server 2011 operating
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Release 8.2 User Guide P/N 302-000-658 REV 01 Copyright 2007-2014 EMC Corporation. All rights reserved. Published in the USA.
Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version 1.0. 2014 PROMISE Technology, Inc. All Rights Reserved.
Vess A2000 Series NVR Storage Appliance Windows Recovery Instructions Version 1.0 2014 PROMISE Technology, Inc. All Rights Reserved. Contents Introduction 1 Different ways to backup the system disk 2 Before
Nexio Connectus Cluster Set Up with SQL Server Backend
Nexio Connectus Cluster Set Up with SQL Server Backend 2.1.2 3/20/2014 Edition: A 2.1.2 Publication Information 2014 Imagine Communications. Proprietary and Confidential. Imagine Communications considers
Guide to Installing BBL Crystal MIND on Windows 7
Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive This guide explains how to create and use a Rescue USB flash drive to reinstall and recover the ExtraHop system. When booting
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Version 9.0 User Guide 302-001-755 REV 01 Copyright 2007-2015 EMC Corporation. All rights reserved. Published in USA. Published
TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:
TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link: ftp://ftp.software.ibm.com/storage/tivoli-storagemanagement/maintenance/client/v6r2/windows/x32/v623/
InventoryControl for use with QuoteWerks Quick Start Guide
InventoryControl for use with QuoteWerks Quick Start Guide Copyright 2013 Wasp Barcode Technologies 1400 10 th St. Plano, TX 75074 All Rights Reserved STATEMENTS IN THIS DOCUMENT REGARDING THIRD PARTY
Microsoft SQL Server 2008 R2 (64-bit) Standard Edition Installation Guide
Microsoft SQL Server 2008 R2 (64-bit) Standard Edition Installation Guide Notices 2011 XMPie Inc. All rights reserved. U.S. Patents 6948115, 7406194, 7548338, 7757169 and pending patents. JP Patent 4406364B
Optimizing Dell server deployments with system build and update utility
Optimizing Dell server deployments with system build and update utility Efficient techniques for deploying multiple Dell servers in parallel with RAID configuration, BIOS settings, Firmware updates & operating
UltraBac Documentation. UBDR Gold. Administrator Guide UBDR Gold v8.0
UltraBac Documentation UBDR Gold Bare Metal Disaster Recovery Administrator Guide UBDR Gold v8.0 UBDR Administrator Guide UBDR Gold v8.0 The software described in this guide is furnished under a license
How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade
How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade Executive summary... 2 System requirements... 2 Hardware requirements...
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
Clustering ExtremeZ-IP 4.1
Clustering ExtremeZ-IP 4.1 Installing and Configuring ExtremeZ-IP 4.x on a Cluster Version: 1.3 Date: 10/11/05 Product Version: 4.1 Introduction This document provides instructions and background information
Role-Based Security and its Implementation
Role-Based Security and its Implementation This Dell Technical White Paper describes how OpenManage Essentials supports and implements role-based access control at its operational level. Author(s) R Rajiv
LP 2844 Thermal Printer
Quick Installation Guide FedEx Ship Manager Software FedEx Ship Manager at fedex.com LP 2844 Thermal Printer Step 1: Confirm Printer Kit Contents Your printer kit contains: 1. Thermal Printer 4. Serial
Team Foundation Server 2012 Installation Guide
Team Foundation Server 2012 Installation Guide Page 1 of 143 Team Foundation Server 2012 Installation Guide Benjamin Day [email protected] v1.0.0 November 15, 2012 Team Foundation Server 2012 Installation
HP ProLiant Cluster for MSA1000 for Small Business... 2. Hardware Cabling Scheme... 3. Introduction... 3. Software and Hardware Requirements...
Installation Checklist HP ProLiant Cluster for HP StorageWorks Modular Smart Array1000 for Small Business using Microsoft Windows Server 2003 Enterprise Edition November 2004 Table of Contents HP ProLiant
Honeywell Internet Connection Module
Honeywell Internet Connection Module Setup Guide Version 1.0 - Page 1 of 18 - ICM Setup Guide Technical Support Setup - Guide Table of Contents Introduction... 3 Network Setup and Configuration... 4 Setting
User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream
User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner
EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014. Version 1
EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014 Version 1 NEC EXPRESSCLUSTER X 3.x for Windows SQL Server 2014 Quick Start Guide Document Number ECX-MSSQL2014-QSG, Version
Modular Messaging. Release 4.0 Service Pack 4. Whitepaper: Support for Active Directory and Exchange 2007 running on Windows Server 2008 platforms.
Modular Messaging Release 4.0 Service Pack 4 Whitepaper: Support for Active Directory and Exchange 2007 running on Windows Server 2008 platforms. April 2009 2006-2009 Avaya Inc. All Rights Reserved. Notice
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution
EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Version 8.2 Service Pack 1 User Guide 302-001-235 REV 01 Copyright 2007-2015 EMC Corporation. All rights reserved. Published
StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster
#1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover JANUARY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind
ActiveImage Protector 3.5 for Hyper-V with SHR. User Guide - Back up Hyper-V Server 2012 R2 host and
ActiveImage Protector 3.5 for Hyper-V with SHR User Guide - Back up Hyper-V Server 2012 R2 host and restore individual virtual machines 2 nd Edition July 7, 2014 Copyright NetJapan, Inc. All Rights Reserved.
Contents. ST9612 Model WIC Printer. Get the original printer s information. Edited 11/04/15
Printer - Replacement The following is a guide on how to swap out a WIC printer with another. A scenario where this might happen is when getting a service replacement for faulty hardware from Source Technologies.
Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide
Direct Storage Access Using NetApp SnapDrive Installation & Administration Guide SnapDrive overview... 3 What SnapDrive does... 3 What SnapDrive does not do... 3 Recommendations for using SnapDrive...
Intel Entry Storage System SS4000-E
Intel Entry Storage System SS4000-E Software Release Notes March, 2006 Storage Systems Technical Marketing Revision History Intel Entry Storage System SS4000-E Revision History Revision Date Number 3 Mar
HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide
HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide Abstract This guide describes the Virtualization Monitor (vmon), an add-on service module of the HP Intelligent Management
SSD Guru. Installation and User Guide. Software Version 1.4
SSD Guru Installation and User Guide Software Version 1.4 Contents Welcome!............................................................................. 1 Key features.........................................................................
Also you need the C-MOR ISO file. This file you will find following this link: http://www.cmor.com/video-surveillance/download-vm.
This Guide will show you the installation of C-MOR Video Surveillance on a Microsoft Hyper- V server. You are able to download the Microsoft Hyper-v 2012 server on http://www.microsoft.com/en-us/server-cloud/hyper-v-server/.
Deploying Windows Streaming Media Servers NLB Cluster and metasan
Deploying Windows Streaming Media Servers NLB Cluster and metasan Introduction...................................................... 2 Objectives.......................................................
Dell Server Management Pack Suite Version 5.0.1 For Microsoft System Center Operations Manager And System Center Essentials User s Guide
Dell Server Management Pack Suite Version 5.0.1 For Microsoft System Center Operations Manager And System Center Essentials User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information
AXIS Camera Station Quick Installation Guide
AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera
ReadyNAS Duo Setup Manual
ReadyNAS Duo Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA February 2008 208-10215-01 v1.0 2008 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR, the NETGEAR logo,
Configuring a Trimble Sps 461 using the Ethernet Connection GETTING THE GPS ON THE NETWORK HTTP PORT. By Bob Glover
Configuring a Trimble Sps 461 using the Ethernet Connection By Bob Glover With most computers today, finding a serial port on board is a thing of the past. Increasingly, fewer and fewer computers even
Installing Global Logger USB Drivers
Installing Global Logger USB Drivers For 32-bit Windows 8, skip to the section labeled, Continue with Driver Installation. For 64-bit Windows 8, start the process here. At the time of this writing, the
NI InsightCM Server Version 1.0
GETTING STARTED NI InsightCM Server Version 1.0 This document contains step-by-step instructions for the setup tasks you must complete to connect an NI Condition Monitoring System to NI InsightCM Server
ZP 500 Plus Thermal Printer
Quick Installation Guide FedEx Ship Manager Software FedEx Ship Manager at fedex.com ZP 500 Plus Thermal Printer Step 1: Confirm Printer Kit Contents Your printer kit contains: 1. Thermal Printer 4. USB
LockView 4.3.1 CompX Database & Network Configuration & Installation Manual
LockView 4.3.1 CompX Database & Network Configuration & Installation Manual Table of Contents CompX Database & Network Configuration & Installation Manual Introduction... 4 Installation Requirements...
How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The
1-bay NAS User Guide INDEX Index... 1 Log in... 2 Basic - Quick Setup... 3 Wizard... 3 Add User... 6 Add Group... 7 Add Share... 9 Control Panel... 11 Control Panel - User and groups... 12 Group Management...
Configure the idrac Remote Access Console
Configure the idrac Remote Access Console If your ExtraHop system is deployed in a data center or other remote environment, you might need to remotely access the console and its power-management features.
Virtualizing your Datacenter
Virtualizing your Datacenter with Windows Server 2012 R2 & System Center 2012 R2 Part 2 Hands-On Lab Step-by-Step Guide For the VMs the following credentials: Username: Contoso\Administrator Password:
Clustering VirtualCenter 2.5 Using Microsoft Cluster Services
Clustering VirtualCenter 2.5 Using Microsoft Cluster Services This paper documents the steps to successfully implement a high availability solution for VirtualCenter 2.5 using Microsoft s cluster services.
Performing Updates on a PowerEdge VRTX System Using CMC 1.0
Performing Updates on a PowerEdge VRTX System Using CMC 1.0 This Dell Technical White Paper provides information about how to update CMC, Chassis Infrastructure, IOM, and Software Component firmware using
Network Monitoring User Guide Pulse Appliance
Network Monitoring User Guide Pulse Appliance 2007 Belkin Corporation. All rights reserved. F1DUXXX All trade names are registered trademarks of respective manufacturers listed. Table of Contents Pulse
Microsoft SQL Server 2008 R2 Express Edition with Advanced Services Installation Guide
Microsoft SQL Server 2008 R2 Express Edition with Advanced Services Installation Guide Notices 2011 XMPie Inc. All rights reserved. U.S. Patents 6948115, 7406194, 7548338, 7757169 and pending patents.
Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance
Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance This white paper compares the performance of blade-to-blade network traffic between two enterprise blade solutions: the Dell
Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide
Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.
Shield Pro. Quick Start Guide
Shield Pro In the box: Power Adapter Shield Network Cables Let s get started! Before installing Shield you will first need to determine which operating mode best fits your needs. To help with this process,
LockView 4.2 CompX Database & Network Configuration & Installation Manual
LockView 4.2 CompX Database & Network Configuration & Installation Manual Table of Contents CompX Database & Network Configuration & Installation Manual Introduction... 4 Installation Requirements... 5
19 LCD / 8 CHANNEL DVR COMBO WITH 160GB HDD & 4 CAMERAS
19 LCD / 8 CHANNEL DVR COMBO WITH 160GB HDD & 4 CAMERAS Overview - Remote Viewing MODEL: SG19LD804-161 www.lorexcctv.com Copyright 2007 LOREX Technology Inc. Remote Viewing Overview Remote Viewing Overview
Efficient Video Distribution Networks with.multicast: IGMP Querier and PIM-DM
Efficient Video Distribution Networks with.multicast: IGMP Querier and PIM-DM A Dell technical white paper Version 1.1 Victor Teeter Network Solutions Engineer This document is for informational purposes
Dell High Availability Solutions Guide for Microsoft Hyper-V R2. A Dell Technical White Paper
Dell High Availability Solutions Guide for Microsoft Hyper-V R2 A Dell Technical White Paper THIS WHITE PAPER IS FOR INFORMATIONAL PURPOPERATING SYSTEMS ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL
WhatsUp Gold v16.3 Installation and Configuration Guide
WhatsUp Gold v16.3 Installation and Configuration Guide Contents Installing and Configuring WhatsUp Gold using WhatsUp Setup Installation Overview... 1 Overview... 1 Security considerations... 2 Standard
Configuring ThinkServer RAID 100 on the TS140 and TS440
Configuring ThinkServer RAID 100 on the TS140 and TS440 Lenovo ThinkServer TS Series Servers Lenovo Enterprise Product Group Version 1.0 September 17, 2013 2013 Lenovo. All rights reserved. LENOVO PROVIDES
Dwebs IIS Log Archiver Installation and Configuration Guide for Helm 4
Dwebs IIS Log Archiver Installation and Configuration Guide for Helm 4 Dwebs Ltd http://www.dwebs.ltd.uk January 2009 Doc: Helm 4.1.0.0 Mod Ver: 1.0.0.0 The names of actual companies and products mentioned
ThinkServer RD540 and RD640 Operating System Installation Guide
ThinkServer RD540 and RD640 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and
Microsoft SQL Server 2008 R2 Express Edition with Advanced Services Installation Guide
Microsoft SQL Server 2008 R2 Express Edition with Advanced Services Installation Guide Notices 2010 XMPie Inc. All rights reserved. U.S. Patents 6948115, 7406194, 7548338, 7757169 and pending patents.
Dell Statistica Document Management System (SDMS) Installation Instructions
Dell Statistica Document Management System (SDMS) Installation Instructions 2015 Dell Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described
CLEARONE DOCUMENT 801-000-002 (REVISION 1.0) October, 2008. with Converge Pro Units
APPLICATION NOTES Converge Pro Products CLEARONE DOCUMENT 801-000-002 (REVISION 1.0) October, 2008. Troubleshooting USB Connections with Converge Pro Units Description This document explains how to connect
ThinkServer RS140 Operating System Installation Guide
ThinkServer RS140 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and Support
Downloading Driver Files
The following instructions are for all DPAS supported Intermec printers. The Intermec InterDriver EasyCoder PD42 (203 dpi) - IPL driver has been tested and recommended for DPAS use. This driver will support
Configuring Single Sign-On for Application Launch in OpenManage Essentials
Configuring Single Sign-On for Application Launch in OpenManage Essentials This Dell Technical White paper provides information required to configure Single Sign-On (SSO)for launching the idrac console
Crystal Reports Installation Guide
Crystal Reports Installation Guide Version XI Infor Global Solutions, Inc. Copyright 2006 Infor IP Holdings C.V. and/or its affiliates or licensors. All rights reserved. The Infor word and design marks
Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide
Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
Moving the TRITON Reporting Databases
Moving the TRITON Reporting Databases Topic 50530 Web, Data, and Email Security Versions 7.7.x, 7.8.x Updated 06-Nov-2013 If you need to move your Microsoft SQL Server database to a new location (directory,
USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION. www.pesa.com August 2014 Phone: 256.726.9200. Publication: 81-9059-0703-0, Rev. C
USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION Publication: 81-9059-0703-0, Rev. C www.pesa.com Phone: 256.726.9200 Thank You for Choosing PESA!! We appreciate your confidence in our products. PESA produces
