Switch Quick Configuration CLI Guide for
|
|
|
- Annabel Adams
- 10 years ago
- Views:
Transcription
1 Switch Quick Configuration CLI Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Release : 1.0d 1 / 23
2 Release : 1.0d 2 / 23
3 The information in this User s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license. IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA. Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product. Manual Revision 1.0d Release Date: March 13, 2013 Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not copy any part of this document. Copyright 2013 by SUPER MICRO COMPUTER INC. All rights reserved. Printed in the United States of America Release : 1.0d 3 / 23
4 Contents 1 Introduction Basic Configurations Console Port Management IP Address Changing Management IP Address Default Gateway User Accounts Interface MTU and Jumbo Frames Interface Description Configuring Interface Range Energy Efficient Ethernet Stacking Tracking Uplink Failure Saving Configurations Upgrading Firmware Resetting to Factory Defaults VLAN Configurations VLAN Example Link Aggregation (LA) Link Aggregation Example Release : 1.0d 4 / 23
5 1 Introduction This document is designed to provide Supermicro Switch users with the information required to configure the basic functionalities on the switch through the Command Line Interface (CLI). The Supermicro Switch command line interface is accessible through an RS232 console port, or viatelnet and SSH connections. The Supermicro Switch CLI is designed to follow industry standard CLI commands. Standard features including context sensitive help and auto-completion-on-tab-key are supported. After logging in to the switch CLI, you are automatically in the user EXEC mode. This mode supports show commands and minimal configuration commands. To enter the configuration mode, use the command configure terminal. For example: SMIS# configure terminal SMIS(config)# To exit to EXEC mode, use the command exit or end. Note: Most of the contents of this manual apply to all of these switch products: SSE-G48-TG4, SSE-G24-TG4, SSE-X24S, SSE-X24SR, SSE-X3348S, SSE-X3348SR, SSE-X3348T SSE-X3348TR SBM-GEM-X2C, SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM. In a few sections the contents differ for these products. In those specific places, the applicable product is clearly identified. So if any particular product is not mentioned, you can assume that the contents are valid for these seven products. Release : 1.0d 5 / 23
6 2 Basic Configurations 2.1 Console Port Switch SSE-G24-TG4 SSE-G48-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Console Port These switches have a DB9 RS232 console port. Use the serial cable provided with the switch to connect the switch console port to any computer COM port. These switches have an RJ45 connector for the RS232 console port. Connect a regular straight RJ45 Ethernet cable to the switch console port, and connect the other end of the RJ45 Ethernet cable to the console adapter provided with the switch. The console adapter coverts the RJ45 to DB9 port. Connect the DB9 end of the console adapter to any computer COM port. This switch has a USB connector for the RS232 console port. Use the USB to DB9 serial cable provided with the switch to connect the USB console port to any computer COM port. The computer COM port settings should be as follows: Baudrate: 9600 Data: 8 bit Parity: none Stop: 1 bit Flow Control: none Release : 1.0d 6 / 23
7 2.2 Management IP Address The default management IP address for all Supermicro switch products is: Switch SSE-G24-TG4 SSE-G48-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Management IP Interface The management IP is configured for VLAN 1. All front 1G ports and back 10G ports are configured as untagged member ports of VLAN 1 by default. You can connect to any of the front panel 1G ports or back panel 10G ports to manage the switch with management IP. The management IP is configured for a 1G management Ethernet port. You can connect to this management Ethernet port with the management IP. If you prefer to manage through the 10G ports, then you can assign the desired management IP address to VLAN 1. Alternatively, you can create any layer 3 VLAN to manage the switch through its 10G ports. For blade switches, you can manage with the default IP through the CMM Ethernet connections. The internal management Ethernet ports of the blade switches are connected with the CMM Ethernet ports internally. If you prefer to manage through the front panel Ethernet ports, then you can assign the desired management IP address to VLAN 1. Alternatively, you can create any layer 3 VLAN and manage the switch through its front Ethernet ports. Release : 1.0d 7 / 23
8 2.2.1 Changing Management IP Address Function Command Syntax Example Configure management IP address Remove management IP address Get management IP through DHCP View management IP address ip address <ip addr> no ip address ip address dhcp show ip interface SMIS(config)# ip address SMIS(config)# no ip address SMIS(config)# ip address dhcp SMIS# show ip interface Default Gateway The default gateway can be configured only for the SBM-GEM-X2C, SBM-GEM-X2C+, SBM- GEM-X3S+, SBM-XEM-X10SM and SSE-X24S, SSE-X24SR, SSE-X3348S, SSE-X3348SR, SSE-X3348T and SSE-X3348TR switches. Use the command ip gateway <ip addr> to configure the gateway. For example: SMIS(config)# ip gateway For other switches (SSE-G24-TG4 and SSE-G48-TG4) you can add the required route to access the gateway for a desired network. The route can be added using the command ip route <prefix> <mask> {<next hop> vlan <id> interface }. For example: SMIS(config)# ip route Note: For blade switches SBM-GEM-X2C, SBM-GEM-X2C+, SBM-GEM-X3S+ and SBM-XEM-X10SM the management IP address and default gateway can also be configured from the CMM management interface. The management IP address and gateway of the switch are saved automatically into switch NVRAM. So you do not need to do a save configuration command in order to save the management IP and gateway. Release : 1.0d 8 / 23
9 2.3 User Accounts The default administrative user name for all Supermicro switches is ADMIN and the password for all these switches is also ADMIN. The password for this ADMIN user can be changed using the command username ADMIN password <new password>. New users can be created with different privilege levels. Fifteen is the highest privilege it equals ADMIN user. One is the lowest privilege which only allows the user to view the configurations; the user may not modify them. The default privilege is at least one. Function Command Syntax Examples Create New User username <name> [password <password>] [privilege <level>] SMIS(config)# username abc password abc privilege 15 SMIS(config)# username new1 password new1 Remove user no username <name> SMIS(config)# no username abc Change password username <name> [password <password>] SMIS(config)# username abc password aa12 View users list users SMIS# list users Release : 1.0d 9 / 23
10 2.4 Interface MTU and Jumbo Frames The interface MTU can be changed by using the mtu command in interface mode. The default MTU is 1500 bytes. The maximum supported MTU is The Supermicro switch MTU refers only to the layer 2 payload size. Hence the MTU of 9202 means a total in-wire MTU of 9220 (14 bytes Ethernet Header plus 4 bytes FCS are added). To configure the MTU for any interface, the interface must be administratively brought down using the shutdown command. Function Command Syntax Examples Configure MTU mtu <frame size> Example to configure MTU for port gi 0/1 SMIS(config)# interface gi 0/1 SMIS(config-if)# shutdown SMIS(config-if)# mtu 9000 SMIS(config-if)# no shutdown View MTU show interface mtu SMIS# show interface mtu To configure jumbo frame support just configure the MTU as 9200 bytes (or to any other jumbo size preferred up to 9202 bytes). 2.5 Interface Description Interfaces can be assigned with a description or name in text. This helps users to identify or remember the interface connections with other components on the network. Function Command Syntax Examples Configure interface description description <string> Example to configure description for gi 0/1 SMIS(config)# interface gi 0/1 SMIS(config-if)# description lab network View description show interface description SMIS# show interface description Release : 1.0d 10 / 23
11 2.6 Configuring Interface Range To configure the same parameters on multiple interfaces, the interface range command can be useful. For example, to configure the MTU as 9000 for all gi 0/1 to gi 0/24 ports, using the range command allows all to be configured in one sequence instead of requiring that they be configured on the individual interfaces 24 times. Function Command Syntax Examples Interface Range Command interface range <intf str> Example to configure mtu for 24 ports from gi 0/1 to gi 0/24 SMIS(config)# interface range gi0/1-24 SMIS(config-if)# shut SMIS(config-if)# mtu 9000 Example to configure description for 3 ports gi 0/1, gi 0/5 and gi 0/10 SMIS(config)# int range gi0/1,gi0/5,gi0/10 SMIS(config-if)# description test network 2.7 Energy Efficient Ethernet IEEE defines the Ethernet standard and subsequent power requirements based on cable connections operating at 100 meters. Enabling power saving mode can reduce power used for cable lengths of 60 meters or less, with more significant reduction for cables of 20 meters or less, and continue to ensure signal integrity. IEEE 802.3az specifies a mechanism for reducing power consumption when a link is idle. It is known as Energy Efficient Ethernet (EEE). The power-saving methods provided by this switch include this EEE power saving feature when there is no activity on a link: Under normal operation, the switch continuously auto-negotiates to find a link partner, keeping the MAC interface powered up even if no link connection exists. When using power-savings mode, the switch checks for energy on the circuit to determine if there is a link partner. If none is detected, the switch automatically turns off the transmitter, and most of the receive circuitry (entering Sleep Mode). In this mode, the low-power energy-detection circuit continuously checks for energy on the cable. If none is detected, the MAC interface is also powered down to save additional energy. If energy is detected, the switch immediately turns on both the transmitter and receiver functions, and powers up the MAC interface. Release : 1.0d 11 / 23
12 This feature is Off by default. To enable the feature on a particular port use the following command: input interface ex <interface-id>. SMIS(config)# interface ex 0/1 input EEE mode and then input exit. SMIS(config-if)# EEE mode To confirm that the port is configured for EEE: input show interface ex <interface-id>. SMIS(config)# show interface ex 0/1 To disable this feature: input interface ex <interface-id>. SMIS(config)# interface ex 0/1 input no EEE mode and then input exit. SMIS(config-if)# no EEE mode To confirm that EEE is disabled on the port: input show interface ex <interface-id>. SMIS(config)# show interface ex 0/1 Release : 1.0d 12 / 23
13 2.8 Stacking SSE-G24-TG4 and SSE-G48-TG4 switches support stacking up to 16 switches. SBM-GEM-X2C and SBM-GEM-X2C+ switches support stacking up to 8 switches. Function Command Syntax Examples Enable stacking on switch Remove from stacking View stack information stack { priority {PM BM PS} } {switchid <NodeId (1-16)>} {ports <xg1,xg2,..>} no stack [switch id] show stack details Example to enable stacking with switch identifier 1 as preferred master using xg3 and xg4 as stacking ports SMIS# stack priority PM switchid 1 ports xg3-4 Example to enable stacking with switch identifier 2 as preferred slave using xg1 and xg2 as stacking ports SMIS# stack priority PS switchid 2 ports xg1-2 Example to enable stacking with switch identifier 3 as back up master using xg1 and xg2 as stacking ports SMIS# stack priority BM switchid 3 ports xg1-2 To remove this switch from stack SMIS# no stack To remove switch 2 from stack from master CLI SMIS# no stack switch 2 SMIS# show stack details Note: 1. Do not use the same switch ID for multiple switches on the stack. 2. Only one master switch may be configured in a stack. The slave switches will not allow you to configure any thing except to disable stacking. To login to a slave switch console port, use the login name of stackuser and password of stack Make sure all stacked switches run the same version of firmware! 4. Only the same switch models can be stacked together. For example, the SSE-G24-TG4 switch can only be stacked with other SSE-G24-TG4 switches. Release : 1.0d 13 / 23
14 2.9 Tracking Uplink Failure The Uplink Failure Tracking Feature (ULFT) is useful for blade switches (SBM-GEM-X2C, SBM- GEM-X2C+, SBM-GEM-X3S+ and SBM-XEM-X10SM). This helps blade servers to move to redundant Ethernet ports in case any blade switch uplink fails. The user can configure one or more groups for ULFT. Each group can have one or more uplinks and one or more downstream ports. Function Command Syntax Examples Enabling uplink failure tracking feature Disabling uplink failure tracking feature Creating group Adding uplink to group Adding downstream ports to group link-status-tracking enable link-status-tracking disable link-status-tracking group <id> link-status-tracking group <id> upstream link-status-tracking group <id> downstream SMIS(config)# link-status-tracking enable SMIS(config)# link-status-tracking disable SMIS(config)# link-status-tracking group 1 SMIS(config-if)# link-status-tracking group 1 upstream SMIS(config-if)# link-status-tracking group 1 downstream View configuration show link-status-tracking SMIS# show link-status-tracking For example if it is desired to bring down all fourteen ports from gi 0/1 to gi 0/14 when uplink interfaces gi 0/15 and gi 0/16 go down: Note: SMIS# configure terminal SMIS(config)# link-status-tracking enable SMIS(config)# link-status-tracking group 1 SMIS(config)# interface range gi0/15-16 SMIS(config-if)# link-status-tracking group 1 upstream SMIS(config)# interface range gi0/1-14 SMIS(config-if)# link-status-tracking group 1 downstream If more than one uplink port is configured, all downstream ports will be brought down only when all upstream ports are down. Release : 1.0d 14 / 23
15 2.10 Saving Configurations Switch configurations can be saved using the command write startup-config. A configuration saved as a default configuration will be loaded automatically every time the switch reboots. Function Command Syntax Examples Save the configuration as default Save the configuration on a file Save the configuration on a remote TFTP machine To view all saved configuration files To delete a particular configuration file To erase the default configuration To choose any saved configuration file as the default config write startup-config write flash:filename write tftp://ipaddress/filename list files erase flash:filename erase startup-config set startup-config <file> SMIS# write startup-config SMIS# write flash:abc SMIS# write tftp:// /abc SMIS# list files SMIS# erase flash:abc SMIS# erase startup-config SMIS# configure terminal SMIS(config)# set startup-config abc Release : 1.0d 15 / 23
16 2.11 Upgrading Firmware Switch firmware can be upgraded from the CLI using the command firmware upgrade. Function Command Syntax Examples To upgrade firmware To upgrade to fallback firmware firmware upgrade tftp://<ipaddress>/<filename> flash:normal firmware upgrade tftp://<ipaddress>/<filename> flash:fallback SMIS# firmware upgrade tftp:// /swithc_firmware_1.0.7.bin flash:normal SMIS# firmware upgrade tftp:// /swithc_firmware_1.0.7.bin flash:fallback Make sure the TFTP server is running on the computer where the firmware image is available Resetting to Factory Defaults Supermicro switches can be reset to factory defaults using the CLI command reset-to-factorydefault. Function Command Syntax Examples Reset to factory defaults reset-to-factory-defaults SMIS# configure terminal SMIS(config)# reset-to-factory-defaults Release : 1.0d 16 / 23
17 3 VLAN Configurations The SSE-G24-TG4, SSE-G48-TG4, SBM-GEM-X2C, SBM-GEM-X2C+ and SBM-GEM-X3S+ switches all support 1024 static VLANs. The SSE-X24S, SSE-X24SR, SSE-X3348S, SSE- X3348SR, SSE-X3348T, SSE-X3348TR and SBM-XEM-X10SM switches support 4K static VLANs. The below table describes the basic VLAN configuration commands. Function Command Syntax Examples Creating VLAN vlan <vlan id> SMIS(config)# vlan 10 SMIS(config-vlan)# Adding tagged ports to VLAN Adding untagged ports to VLAN Forbidding ports to VLAN ports <ports list> tagged SMIS(config-vlan)# ports gi 0/1-10 tagged ports <ports list> untagged SMIS(config-vlan)# ports gi 0/11,0/13 untagged ports <ports list> forbidden SMIS(config-vlan)# ports gi 0/15-20,0/23 forbidden Removing ports from VLAN no ports <ports list> <tagged untagged forbidden> To remove tagged ports SMIS(config-vlan)# no ports gi 0/1-5 tagged To remove untagged ports SMIS(config-vlan)# no ports gi 0/1-5 untagged To remove forbidden ports SMIS(config-vlan)# no ports gi 0/1-5 forbidden Deleting VLAN no vlan <vlan-id> SMIS(config)# no vlan 10 Configuring name to VLAN name <string> SMIS(config-vlan)# name labvlan Port VLAN ID switchport pvid <vlan> To configure pvid for port gi 0/1 as vlan 10 SMIS(config)# interface gi 0/1 SMIS(config-if)# switchport pvid 10 Release : 1.0d 17 / 23
18 Note: PVID Supermicro switches associate all untagged packets received as VLAN 1. This happens irrespective of the VLANs associated with the received ports. Therefore if you need untagged packets to be associated with a particular VLAN of the ports, it is necessary to configure a pvid for the ports. 3.1 VLAN Example Requirements: A. Limit VLAN 1 to only one port gi 0/1 B. Ports gi 0/2-5 untagged member of VLAN 100 C. Ports gi 0/6-10 tagged member of VLAN 100 D. Ports gi 0/11-15 untagged member of VLAN n 200 E. Ports gi 0/16-20 tagged member of VLAN 200 F. Port ex 0/1 tagged member of VLAN 100 and 200 First remove all other ports from VLAN 1 except required port gi 0/1 with the commands below: SMIS# config term SMIS(config)# vlan 1 SMIS(config-vlan)# no ports gi 0/2-24 untagged SMIS(config-vlan)# no ports ex 0/1-4 untagged SMIS(config-vlan)# exit The above commands assumed the port numbers used on SSE-G24-TG4 switches. On other switches use appropriate port numbers. Create VLAN 100 and add untagged and tagged ports as required: SMIS(config)# vlan 100 SMIS(config-vlan)# ports gi 0/2-5 untagged SMIS(config-vlan)# ports gi 0/6-10 tagged SMIS(config-vlan)# ports ex 0/1 tagged SMIS(config-vlan)# exit Create VLAN 200 and add untagged and tagged ports as required: SMIS(config)# vlan 200 SMIS(config-vlan)# ports gi 0/11-15 untagged SMIS(config-vlan)# ports gi 0/16-20 tagged SMIS(config-vlan)# ports ex 0/1 tagged SMIS(config-vlan)# exit Configure the switch port pvid also for these ports as below: SMIS(config)# interface range gi0/2-10 SMIS(config-if)# switchport pvid 100 SMIS(config)# interface range gi0/11-20 Release : 1.0d 18 / 23
19 SMIS(config-if)# switchport pvid 200 Release : 1.0d 19 / 23
20 Let us choose pvid for ex 0/1 as 200 in this case: SMIS(config)# interface ex 0/1 SMIS(config-if)# switchport pvid 200 Release : 1.0d 20 / 23
21 4 Link Aggregation (LA) Link Aggregation (LA) is a method of combining multiple parallel physical connections into a single logical connection(trunk), thus allowing increased bandwidth for a particular network path beyond what a single connection could sustain. By taking multiple LAN connections and treating them as a unified, aggregated link, practical benefits in many applications can be achieved. For example, link aggregation provides redundancy in case one of the links fails. Link Aggregation also provides load balancing so that processing and communication activity is distributed across several links in a trunk ensuring that no single link is overwhelmed. Other terms often used to describe this Link Aggregation method include port trunking, link bundling, bonding, or teaming. These umbrella terms encompass industry standards such as IEEE 802.1ax Link Aggregation Control Protocol (LACP) for wired Ethernet, or the previous IEEE 802.3ad, as well as various proprietary solutions. In this manual we will also refer to a particular group of aggregated links as a Port Channel. Supermicro switches support both static link aggregation and dynamic link aggregation using IEEE 802.3ad and LACP. Up to 24 Port Channels can be configured on an individual switch and each Port Channel can contain up to 8 members. The table below describes the basic link aggregation / port channel configuration commands: Function Command Syntax Examples Enable port channel feature set port-channel enable SMIS(config)# set port-channel enable Create port channel interface port-channel SMIS(config)# interface port-channel 1 Associating ports to port-channel statically Associating ports to LACP port channel channel-group <channel> mode manual channel-group <channel> mode <active passive> First ho into desired port by typing the command interface gi/ex <port>. For example: SMIS(config)# interface range gi0/15-16 Configure the port channel ID using the channel-group command SMIS(config-if)# channel-group 1 mode on First ho into desired port by typing the command interface gi/ex <port>. For example: SMIS(config)# interface range gi0/15-16 Configure the port channel ID using the Release : 1.0d 21 / 23
22 channel-group command SMIS(config-if)# channel-group 1 mode active Activate created port channel no shutdown SMIS(config)# int port-channel 1 SMIS(config-if)# no shutdown SMIS(config-if)#exit Once a port-channel is created, it can be added as required to any VLAN configuration(s). The pvid can also be configured for port channel interfaces just as it is for any other ports. 4.1 Link Aggregation Example Requirement: A. Ports gi 0/15 and 0/16 need to be trunked B. And this trunk has to carry VLANs 100 and 200 First enable the port channel feature: SMIS# config term SMIS(config)# set port-channel enable Crate the port channel interface: SMIS(config)# int port-channel 1 Add ports to create the port channel interface: SMIS(config)# int range gi0/15-16 SMIS(config-if)# channel-group 1 mode on Associate VLANs to this port channel: SMIS(config)# vlan 100 SMIS(config-vlan)# ports po 1 tagged SMIS(config-vlan)# exit SMIS(config)# vlan 200 SMIS(config-vlan)# ports po 1 tagged SMIS(config-vlan)# exit Activate the created port channel: SMIS(config)# int port-channel 1 SMIS(config-if)# no shut Release : 1.0d 22 / 23
23 Release : 1.0d 23 / 23
Switch Web GUI Quick Configuration Guide for
Switch Web GUI Quick Configuration Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Release: 1.0c 1
How To Configure Link Aggregation On Supermicro Switch 2 And 3 (Lan) On A Microsoft Vlan 2 And Vlan 3 (Vlan) (Lan 2) (Vlans) (Lummer) (Powerline) (
L2 / L3 Switches Link Aggregation Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility
L2 / L3 Switches. Remote Network Monitoring (RMON) Configuration Guide
L2 / L3 Switches Remote Network Monitoring (RMON) Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no
L2/L3 Switches. System. Configuration Guide
L2/L3 Switches System Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies
L2 / L3 Switches. Link Layer Discovery Protocol (LLDP) Configuration Guide
L2 / L3 Switches Link Layer Discovery Protocol (LLDP) Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes
What is VLAN Routing?
Application Note #38 February 2004 What is VLAN Routing? This Application Notes relates to the following Dell product(s): 6024 and 6024F 33xx Abstract Virtual LANs (VLANs) offer a method of dividing one
Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B
Management Software AT-S84 User s Guide For the AT-9000/24 Layer 2 Gigabit Ethernet Switch Version 1.1 613-000368 Rev. B Copyright 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication
How To Install An At-S100 (Geo) On A Network Card (Geoswitch)
AT-S100 Version 1.0.3 Patch 1 Management Software for the AT-9000/28 Managed Layer 2 GE ecoswitch and AT-9000/28SP Managed Layer 2 GE ecoswitch Software Release Notes Please read this document before you
Starting a Management Session
Management Software AT-S63 Starting a Management Session AT-S63 Version 2.2.0 for the AT-9400 Layer 2+ Switches AT-S63 Version 3.0.0 for the AT-9400 Basic Layer 3 Switches 613-000817 Rev. A Copyright 2007
AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes
AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes Please read this document before you begin to use the management software. Supported
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches. Software Release Notes
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches Software Release Notes Please read this document before you begin to use the AT-S41 management software.
Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version
Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version Topology Objective Background Configure EtherChannel. Four switches have just been installed. The distribution layer switches are Catalyst
Network Detector Setup and Configuration
339 N. Bernardo Avenue, Suite 200 Mountain View, CA 94043 www.airtightnetworks.net MODE SYST RPS MASTR STAT SPEDUPLX STACK 1 2 3 4 5 6 7 8 91 0 11 12 1X 2X 11X 12X 13 14 15 16 1718 19 20 2122 23 24 13X
Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.
Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials. CHAPTER 5 OBJECTIVES Configure a router with an initial configuration. Use the
L2 / L3 Switches. Simple Network Management Protocol (SNMP) Configuration Guide
-- L2 / L3 Switches Simple Network Management Protocol (SNMP) Configuration Guide Revision 1.0 Supermicro L2/L3 Switches Configuration Guide 2 The information in this USER S MANUAL has been carefully reviewed
Link Aggregation Interoperability of the Dell PowerConnect 5316M with Cisco IOS or Cisco CatOS based Switches. By Bruce Holmes
Link Aggregation Interoperability of the Dell PowerConnect 5316M with Cisco IOS or Cisco CatOS based Switches By Bruce Holmes August 2005 Contents Introduction...3 Link Aggregation with Gigabit Ethernet
Connecting the DG-102S VoIP Gateway to your network
Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information
Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide
Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs Dell Storage Engineering October 2015 A Dell Deployment and Configuration Guide Revisions Date February 2013 October 2013 March 2014
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch. Software Release Notes
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S60 management software. The AT-S60
Chapter 7 Configuring Trunk Groups and Dynamic Link Aggregation
Chapter 7 Configuring Trunk Groups and Dynamic Link Aggregation This chapter describes how to configure trunk groups and 802.3ad link aggregation. Trunk groups are manually-configured aggregate links containing
Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance
CHAPTER 4 Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance This chapter describes how to configure the switch ports and VLAN interfaces of the ASA 5505 adaptive
SUPER SMC LCD. User's Guide. Revision 1.0
SUPER SMC LCD User's Guide Revision 1.0 The information in this User s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
FSM73xx GSM73xx GMS72xxR Shared access to the Internet across Multiple routing VLANs using a Prosafe Firewall
FSM73xx GSM73xx GMS72xxR Shared access to the Internet across Multiple routing VLANs using a Prosafe Firewall This document describes how to: - Create multiple routing VLANs - Obtain Internet access on
Dotworkz NVR Series User Manual. Rev 1.26
Dotworkz NVR Series User Manual Rev 1.26 The information in this User s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that
ProCurve Switch 1700-8 ProCurve Switch 1700-24
Management and Configuration Guide ProCurve Switch 1700-8 ProCurve Switch 1700-24 www.procurve.com ProCurve Series 1700 Switch Management and Configuration Guide Copyright 2007 Hewlett-Packard Development
OLT LTP-8X_v3.20.2.3056. Appendix to Operation Manual OLT LTP-8X Quick Configuration Guide Central Office Node Terminal
OLT LTP-8X_v3.20.2.3056 Appendix to Operation Manual Central Office Node Terminal TABLE OF CONTENTS 1 SUMMARY... 3 2 CONNECTION TO COMMAND LINE INTERFACE (CLI)... 4 2.1 Connection to Telnet/SSH... 4 2.2
Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance
CHAPTER 5 Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance This chapter describes how to configure the switch ports and VLAN interfaces of the ASA 5505 adaptive
LINK AGGREGATION INTEROPERABILITY OF THE DELL POWERCONNECT 6200 SERIES
LINK AGGREGATION INTEROPERABILITY OF THE DELL POWERCONNECT 6200 SERIES WITH CISCO IOS OR CISCO CATOS BASED SWITCHES By Bruce Holmes CONTENTS INTRODUCTION 3 LINK AGGREGATION WITH GIGABIT ETHERNET CISCO
A Principled Technologies white paper commissioned by Dell Inc.
A Principled Technologies white paper commissioned by Dell Inc. TABLE OF CONTENTS Table of contents... 2 Summary... 3 Features of Simple Switch Mode... 3 Sample scenarios... 5 Testing scenarios... 6 Scenario
Networking Solutions for Storage. Application Notes
Networking Solutions for Storage Application Notes Table of Contents Introduction... 3 How to Use this Document... 3 Reference Configuration... 4 Assumptions... 4 Global Configuration Notes... 5 Sample
Configuring iscsi Multipath
CHAPTER 13 Revised: April 27, 2011, OL-20458-01 This chapter describes how to configure iscsi multipath for multiple routes between a server and its storage devices. This chapter includes the following
Lab 2 - Basic Router Configuration
CS326 Fall 2001 Room: PAI 5.48 Name: Lab 2 - Basic Router Configuration In this lab you will learn: the various configuration modes of Cisco 2621 routers how to set up IP addresses for such routers how
How To Manage Das-3324 On A Pc Or Mac Or Mac (For A Pc) With A Das3324 Device On A Ds-3325 (For Mac) Or Ds3324 (For An Ipad)
DAS-3 3 2 4 I P DSL AM Q u i c k St a r t G u i d e Version: 1.0 Date: 2006/07/10 DAS-3324 IP DSLAM Quick Start Guide ❶ This quick start guide will guide you to finish the basic configuration for accessing
Easy Smart Configuration Utility
Easy Smart Configuration Utility REV1.1.0 1910010977 CONTENTS Chapter 1 About this Guide...1 1.1 Intended Readers... 1 1.2 Conventions... 1 1.3 Overview of This Guide... 1 Chapter 2 Getting Started...4
Skills Assessment Student Training Exam
Skills Assessment Student Training Exam Topology Assessment Objectives Part 1: Initialize Devices (8 points, 5 minutes) Part 2: Configure Device Basic Settings (28 points, 30 minutes) Part 3: Configure
Brocade to Cisco Comparisons
1 2 3 Console cables - The console cables are not interchangeable between Brocade and Cisco. Each vendor provides their console cable with each manageable unit it sells. Passwords - Neither Cisco or Brocade
AT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches. Software Release Notes
AT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches Product Documentation Software Release Notes Please read this document before you begin to use the AT-S45 management
Unified Access Point Administrator's Guide
Unified Access Point Administrator's Guide Product Model: DWL-3600AP DWL-6600AP DWL-8600AP Unified Wired & Wireless Access System Release 2.0 November 2011 Copyright 2011. All rights reserved. November
- EtherChannel - Port Aggregation
1 Port Aggregation - EtherChannel - A network will often span across multiple switches. Trunk ports are usually used to connect switches together. There are two issues with using only a single physical
VOICE VLAN SUPPORT IN THE DELL POWERCONNECT 6200
VOICE VLAN SUPPORT IN THE DELL POWERCONNECT 6200 CONTENTS INTRODUCTION 3 REQUIREMENTS 3 USING VOICE VLAN 3 INTERACTION WITH LLDP-MED 4 VOICE VLAN CONFIGURATION 4 CLI CONFIGURATION 4 WEB CONFIGURATION 8
PRILINK PRI Management System
www.prilink.com PRILINK PRI MANAGEMENT SSTEM INSTALLATION GUIDE PRI Management PRILINK PRI Management System Installation Guide Version 3.0, Rev. 12-01-24 Page 1 Table of Contents 1 HARDWARE INSTALLATION...
OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R
OSBRiDGE 5XLi Configuration Manual Firmware 3.10R 1. Initial setup and configuration. OSBRiDGE 5XLi devices are configurable via WWW interface. Each device uses following default settings: IP Address:
Command Line Interface User s Guide
Management Software AT-S85 and AT-S97 Command Line Interface User s Guide AT-MCF2000 Media Converter Series Version 1.3.0 613-000789 Rev. A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part
Install Guide for JunosV Wireless LAN Controller
The next-generation Juniper Networks JunosV Wireless LAN Controller is a virtual controller using a cloud-based architecture with physical access points. The current functionality of a physical controller
CT5760 Controller and Catalyst 3850 Switch Configuration Example
CT5760 Controller and Catalyst 3850 Switch Configuration Example Document ID: 116342 Contributed by Antoine KMEID and Serge Yasmine, Cisco TAC Engineers. Aug 13, 2013 Contents Introduction Prerequisites
Layer 2 / Layer 3 switches and multi-ssid multi-vlan network with traffic separation
Layer 2 / Layer 3 switches and multi-ssid multi-vlan network with traffic separation This document describes the steps to undertake in configuring a Layer 2/Layer 3 switch (in this document a FMS7382S
Configuring EtherChannels
25 CHAPTER This chapter describes how to configure EtherChannel interfaces. For complete syntax and usage information for the commands used in this chapter, refer to the Catalyst 2950 Desktop Switch Command
50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW-50040. Quick Installation Guide
50-Port 10/100/1000Mbps with 4 Shared SFP Managed Gigabit Switch WGSW-50040 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Switch Management... 4 3. Requirements... 5 4. Terminal
3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-
MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features
Chapter 4 Management. Viewing the Activity Log
Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in
An Oracle White Paper October 2013. How to Connect Oracle Exadata to 10 G Networks Using Oracle s Ethernet Switches
An Oracle White Paper October 2013 How to Connect Oracle Exadata to 10 G Networks Using Oracle s Ethernet Switches Introduction... 1 Exadata Database Machine X3-2 Full Rack Configuration... 1 Multirack
Mobility System Software Quick Start Guide
Mobility System Software Quick Start Guide Version 8.0 P/N 530-041387 Rev.05 Table of Contents About this Guide Using the Web Quick Start (WLC2, WLC8, WLC200,WLC800R, and WLC880R) Remotely Configuring
Configuring EtherChannels
CHAPTER 12 This chapter describes how to configure EtherChannels on the Cisco 7600 series router Layer 2 or Layer 3 LAN ports. For complete syntax and usage information for the commands used in this chapter,
MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0
MAX T1/E1 TM VoIP Gateway Quick Start Guide Version 1.0 Contents INTRODUCTION 1 Hardware Needed Software Needed 1 1 NET2PHONE MAX SET UP Hardware Set Up Software Set Up Set Up Internet Protocol (IP) Address
Web-based Management Utility
MicroBlade Web-based Management Utility USER S MANUAL Revison.0b MicroBlade Web-based Management Utility USER S MANUAL The information in this USER S MANUAL has been carefully reviewed and is believed
IP Addressing and Subnetting. 2002, Cisco Systems, Inc. All rights reserved.
IP Addressing and Subnetting 2002, Cisco Systems, Inc. All rights reserved. 1 Objectives Upon completion, you will be able to: Discuss the Types of Network Addressing Explain the Form of an IP Address
VLANs. Application Note
VLANs Application Note Table of Contents Background... 3 Benefits... 3 Theory of Operation... 4 IEEE 802.1Q Packet... 4 Frame Size... 5 Supported VLAN Modes... 5 Bridged Mode... 5 Static SSID to Static
LifeSize Networker Installation Guide
LifeSize Networker Installation Guide November 2008 Copyright Notice 2006-2008 LifeSize Communications Inc, and its licensors. All rights reserved. LifeSize Communications has made every effort to ensure
CCT vs. CCENT Skill Set Comparison
Operation of IP Data Networks Recognize the purpose and functions of various network devices such as Routers, Switches, Bridges and Hubs Select the components required to meet a given network specification
Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
Installation of the On Site Server (OSS)
Installation of the On Site Server (OSS) rev 1.1 Step #1 - Initial Connection to the OSS Having plugged in power and an ethernet cable in the eth0 interface (see diagram below) you can connect to the unit
Configuring LLDP, LLDP-MED, and Location Service
27 CHAPTER Configuring LLDP, LLDP-MED, and Location Service This chapter describes how to configure the Link Layer Discovery Protocol (LLDP), LLDP Media Endpoint Discovery (LLDP-MED), and Location Service
SBI-7125B-T1 Blade Module RAID Setup Procedure
SBI-7125B-T1 Blade Module RAID Setup Procedure Revison 1.0 SBI-7125B-T1 Blade Module RAID Setup Procedure The information in this User s Manual has been carefully reviewed and is believed to be accurate.
Applicazioni Telematiche
Angelo Coiro Laboratorio Applicazioni Telematiche L emulatore Packet Tracer Packet Tracer Cisco Packet Tracer is an academic software that allows to emulate Cisco devices Packet Tracer can be used for
Network Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
ALL8894WMP. User s Manual. 8-Port 10/100/1000Mbps with 4-port PoE. Web Management Switch
ALL8894WMP 8-Port 10/100/1000Mbps with 4-port PoE Web Management Switch User s Manual Content Content I Introduction..3 Product Overview.3 Web Management Feature.3 Specification..4 Mechanical...4 Performance...5
16-PORT POWER OVER ETHERNET WEB SMART SWITCH
16-PORT POWER OVER ETHERNET WEB SMART SWITCH User s Manual (DN-95312) - 0 - Content Web Smart Switch Configure login ---------------------------------- 2 Administrator Authentication Configuration ---------------------------------------------
Unified Access Point Administrator s Guide
Page 1 Table of Contents Section 1 - About This Document...9 Document Organization... 9 Additional Documentation... 9 Document Conventions... 9 Online Help, Supported Browsers, and Limitations... 10 Section
DRO-210i LOAD BALANCING ROUTER. Review Package Contents
DRO-210i LOAD BALANCING ROUTER Review Package Contents Make sure that the package contains the following items. DRO-210i Load Balancing Router 2 Straight Ethernet Cables 1 Cross Over Ethernet Cable 1 Power
Lab 9.1.1 Organizing CCENT Objectives by OSI Layer
Lab 9.1.1 Organizing CCENT Objectives by OSI Layer Objectives Organize the CCENT objectives by which layer or layers they address. Background / Preparation In this lab, you associate the objectives of
IP Routing Between VLANs
hp procurve 10/100-T xl module J4820A hp procurve 10/100-T xl module J4820A hp procurve Mini-GBIC xl mo d ule J4878A module IP Routing Between VLANs This example configuration provides IP routing between
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
Configuring the Edgewater 4550 for use with the Bluestone Hosted PBX
Configuring the Edgewater 4550 for use with the Bluestone Hosted PBX NOTE: This is an advisory document to be used as an aid to resellers and IT staff looking to use the Edgewater 4550 in conjunction with
Cisco ISE Command-Line Interface
This chapter provides information on the Cisco Identity Services Engine (Cisco ISE) command-line interface (CLI) that you can use to configure and maintain Cisco ISE. Cisco ISE Administration and Configuration
GV-Data Capture V3 Series User's Manual
GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights
User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS
MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
Meraki MX50 Hardware Installation Guide
Meraki MX50 Hardware Installation Guide January 2011 Copyright 2010, Meraki, Inc. www.meraki.com 660 Alabama St. San Francisco, California 94110 Phone: +1 415 632 5800 Fax: +1 415 632 5899 Copyright: 2010
ALOHA Load Balancer Quickstart guide
ALOHA Load Balancer Quickstart guide Summary 1 Package contents... 3 2 Preparing your Aloha... 4 3 Cabling... 5 3.1 Howto... 5 3.2 ALBBOX Overview... 6 3.3 ALB2K Overview... 7 3.4 ALB4K, ALB8K and ALB16K
LevelOne VOI-9000. H.323 VoIP Gatekeeper. User Manual
LevelOne VOI-9000 H.323 VoIP Gatekeeper User Manual Quick Guide Step 1: Broadband (ADSL/Cable Modem) Connections For VOI-9000 A. Connect VOI-9000 RJ45 LAN port to Router/ADSL as one of the following connections.
Ruckus Wireless ZoneDirector Command Line Interface
Ruckus Wireless ZoneDirector Command Line Interface Reference Guide Part Number 800-70258-001 Published September 2010 www.ruckuswireless.com Contents About This Guide Document Conventions................................................
Link Aggregation Interoperability of the Dell PowerConnect M6220 with Cisco IOS or Cisco CatOS Based Switches
Link Aggregation Interoperability of the Dell PowerConnect M6220 with Cisco IOS or Cisco CatOS Based Switches By Bruce Holmes Introduction This paper describes how to configure the Dell PowerConnect 6220M
Quick Installation Guide
Quick Installation Guide PRI Gateway Version 2.4 Table of Contents Hardware Setup... 1 Accessing the WEB GUI... 2 Notification LEDs (On the Front Panel of the Gateway)... 3 Creating SIP Trunks... 4 Creating
Bercut-ETL Ethernet/Gigabit Ethernet loopback
Bercut-ETL Ethernet/Gigabit Ethernet loopback Operating manual Version 1.0.4, 2009 Metrotek c Metrotek, 2006 2010 No part of this document may be reproduced in any form or by any means without the written
NeoGate TA Series Quick Installation Guide
NeoGate TA Series Quick Installation Guide Version: V1.1 Yeastar Technology Co., Ltd. Date: November 18, 2014 http://www.yeastar.com 1/15 Contents NeoGate TA Series Quick Installation Guide 1. Preparation
Access Point Configuration
Access Point Configuration Developed by IT +46 Based on the original work of: Onno Purbo and Sebastian Buettrich Goals Provide a general methodology to installation and configuration of access points Give
Lab 1.2.3 Review of Basic Router Configuration with RIP. Objective. Background / Preparation. General Configuration Tips
Lab 1.2.3 Review of Basic Router Configuration with RIP Objective Cable and configure workstations and routers Setup IP addressing scheme using Class B networks Configure Routing Information Protocol (RIP)
Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch. IGS-5225 Series. Quick Installation Guide
Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch IGS-5225 Series Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring DC Power Inputs... 5 4. Terminal
Legal Disclaimers. For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code.
ACS5000 Networking Admin Interface Guide 1/21/2015 Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found to comply with the limits for a Class B
Chapter 7 Lab 7-1, Configuring Switches for IP Telephony Support
Chapter 7 Lab 7-1, Configuring Switches for IP Telephony Support Topology Objectives Background Configure auto QoS to support IP phones. Configure CoS override for data frames. Configure the distribution
Procedure: You can find the problem sheet on Drive D: of the lab PCs. Part 1: Router & Switch
University of Jordan Faculty of Engineering & Technology Computer Engineering Department Computer Networks Laboratory 907528 Lab. 2 Network Devices & Packet Tracer Objectives 1. To become familiar with
HP ProCurve 1800 Switches. Management and Configuration Guide
HP ProCurve 1800 Switches Management and Configuration Guide July 2009 HP ProCurve 1800 Switches Management and Configuration Guide Copyright 2006, 2009 Hewlett-Packard Development Company, L.P. The information
Optimum Business SIP Trunk Set-up Guide
Optimum Business SIP Trunk Set-up Guide For use with IP PBX only. SIPSetup 07.13 FOR USE WITH IP PBX ONLY Important: If your PBX is configured to use a PRI connection, do not use this guide. If you need
LotWan Appliance User Guide USER GUIDE
LotWan Appliance User Guide USER GUIDE Copyright Information Copyright 2014, Beijing AppEx Networks Corporation The description, illustrations, pictures, methods and other information contain in this document
Objectives. Router as a Computer. Router components and their functions. Router components and their functions
2007 Cisco Systems, Inc. All rights reserved. Cisco Public Objectives Introduction to Routing and Packet Forwarding Routing Protocols and Concepts Chapter 1 Identify a router as a computer with an OS and
8-Port Gigabit managed POE Switch. User s Manual. Version: 2.3
8-Port Gigabit managed POE Switch User s Manual Version: 2.3 September 9, 2007 1 TABLE OF CONTENT 1.0 INTRODUCTION... 3 1.1 MAIN FEATURES... 3 1.2 START TO MANAGE THIS SWITCH... 5 2.0 WEB MANAGEMENT...
- Virtual LANs (VLANs) and VTP -
1 - Virtual LANs (VLANs) and VTP - Collision vs. Broadcast Domains A collision domain is simply defined as any physical segment where a collision can occur. Hubs can only operate at half-duplex, and thus
3.1 Connecting to a Router and Basic Configuration
3.1 Connecting to a Router and Basic Configuration Objective This lab will focus on the ability to connect a PC to a router in order to establish a console session and observe the user interface. A console