Room Controller AMRM-41/00.1

Similar documents
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX SA/S Switch Actuators Product Manual

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

Shutter Actuator, 8-fold, 230 V AC, MDRC JA/S , GH Q R0111. ABB i-bus EIB / KNX

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Switch Actuators SA/S

HDL KNX / EIB BUS. Switch Actuators. Guangzhou Hedong Electronic Co.,Ltd (HDL) 1/50

Inwall Room Temperature Unit

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Inwall 4 Input / 4 Output Module

ABB i-bus EIB Logic Module LM/S 1.1

Product and functional description

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

15 Series - Electronic step relay and dimmer. Features SERIE

Push button 3gang standard flush-mounted xx

How To Use A Power Supply On A Powerline 2.2 (Ai)

ABB i-bus EIB / KNX Weather Station WS/S 4.1

Unica for KNX system 226

Light scene push button 8gang comfort flush-mounted xx

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

13 SERIES. Electronic step relays A

ABB i-bus KNX Application Manual Lighting

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

Busch-Watchdog Presence EIB Type:

ABB i-bus KNX DALI-Gateway DG/S 8.1

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP )

ABB i-bus KNX. Room Solutions. ABB STOTZ-KONTAKT GmbH - 2CDC N0202, page 1

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB.

Technical Manual MDT Rain sensor

Basics of Dimming. ISC Learning Centre

Tebis application software

Transmitter Actuator 230V wave UP 560. Operation

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

HERZ-Thermal Actuators

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Application software. Fan coil actuator 2gang RMD. Electrical / Mechanical characteristics : see product information

Installation and User Guide

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

650W Single Output Power Supply

EIB/KNX IP Interface with Power over Ethernet (PoE)

ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1

Product and Application Description

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

FIREDEX Conventional Fire Panels

Electric Rotary Actuator - On/Off or programmable control actuator

DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34)

RRV934. Multi-controller. Synco living

SOLUTIONS FOR THE CONTROL OF THE WHOLE BUILDING

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Model: DC-A2IO Advanced HVAC Controller

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

PRODUCT MANUAL. InZennio Z38i. KNX Touch Panel ZN1VI-TP38i. Program version: 2.2 Manual edition: a

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

IntesisBox KNX Mitsubishi Heavy Industries AC

Operating instructions IV / 2007

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Application Unit, MDRC AB/S 1.1, GH Q R0111

Tebis KNX Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 131

Safety automation solutions

Movement/monitoring 1307/1.0 (6325xx)

MULTIFUNCTION TIME RELAY CRM-93H

DALI RC BASIC SO. Control unit Operating instructions

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

KNX Lighting Control System

ABB i-bus EIB / KNX Room Controller

38 Series - Relay interface modules A

Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

38 Series - Relay interface modules A

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

is then retained absolutely without interruption.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

PRODUCT MANUAL LUMENTO X4 LED. LED Controller ZN1DI-RGBX4. Program version: 1.0 Manual edition: a

Product data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System

Control Devices Catalogue. Control Devices. Preferred and Standard Products

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

EBDSPIR-PRM, EBDSPIR-PRM-IP

EBDSPIR-DD, EBDSPIR-DD-IP

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Transcription:

Room Controller AMRM-41/00.1 The room controller is a simple, low-cost solution for the hotel rooms, which can be used to achieve a single room control, such as heating, cooling, ventilation, lighting, water/fire alarm, emergency buttons and the blinds etc. But also can be used in apartments, hospitals, office buildings, assisted living facilities etc. The room controller compact design enables cover most requirements of the electrical installation of the residential and building control systems and integrate most inputs and output interfaces for a single room automatic control as well as covers all standard functions for a single room control. It offers the following functions: Dry contact input Switch output, Switching of electrical sockets and loads Dimming output Blind or shutter output Control fan speed Control heating/cooling valve In addition to these basic functions, further automation functions can be implemented by a combination with various detectors, such as a presence detector, motion detector. The communication of the devices via the KNX bus also enables control functions as well as sending of emergency signals from the rooms to a control centre. The integrate into a hotel management system enables the efficient management and provision of rooms. For example, when a guest checks out, the room is automatically set to standby mode. Meanwhile the hotel managers can know the use of the room at any time and the service needs etc.

Function Overview- Dry contact input Switch No distinction between long and short operation Distinction between long and short operation Reaction on closing the contact Reaction on opening the contact Reaction on short operation Reaction on long operation No action ON OFF Toggle Internally connecting to output Scan and relay operation delay after bus voltage recovery Limit number of send telegrams Disable input X via 1bit communication object Start-stop-Dimming Only dimming Steps dimming Enable input X (A~T) Switch / Dimming Switch on short operation Dimming and switching Dimming on long operation Internally connecting to output voltage failure Start-stop-Dimming Steps dimming Disable input X via 1bit communication object No distinction between long and short operation Reaction on closing the contact Reaction on opening the contact Value/Forced output Distinction between long and short operation Reaction on short operation Reaction on long operation Internally connecting to Disable input X via 1bit communication object Output: No reaction /1bit/ 2bit/4bit/1byte / 2byte/4byte value 2-push-button, standard 2-push-button, stepping Shutter control 1-push-button, short=stepping, long=moving 1-push-button, short=moving, long=stepping 1-push-button-operation, moving 1-switch-operation, moving 2-push-button, moving [shutter] 2-switch-operation, moving [shutter] Internally connecting to output Disable input X via 1bit communication object

Function Overview- Switch output Reset function Switch state on bus voltage recovery Switch state on bus voltage fail Unchanged Scan and relay operation delay after bus voltage recovery Limit number of send telegrams General switch ON OFF Time for ON Time for OFF Flashing cycles Flashing Position after stop flashing Condition of flash start/stop Enable output X (A~L) Time function ON/OFF delay Delay for switch ON Delay for switch OFF Time for OFF Staircase lighting Control staircase lighting Restart the time for OFF Scene Output is assigned to (scene 1 64 or no allocation) Input 1 enable: if enable, the general switch function is invalid Logic function Input 2 enable Input 3 enable Force operation 1bit: Unchanged/ON/OFF 2bit

Function Overview- Switch output Switch, time and logical function diagram

Function Overview - Shutter / Blind output Louvre adj. /stop UD (up/down) Move UP/DOWN Disable Reference movement No reaction Move to save position Position of louvre after arriving on lower end position Shutter Total move time Duration of louvre adj. Drive Total move time of louvre Pause on change in direction Outputs are disconnected from voltage after Scan and relay operation delay after bus voltage recovery Limit number of send telegrams Status response Response shutter position [0 100%] Response louvre position [0 100%] Response end position (upper and lower) or status byte Enable output X (M~N) Object value of dis. Auto. Control after bus voltage recovery Automatically enable for auto. control Auto. Control Position if sun = 1 (sun is shining) Active safety Position if sun = 0 (sun is not shining) operation Scene Output is assigned to (scene 1 64 or no assignment) Position of safety operation 1 Safety operation Position of safety operation 2 Reset function: Position on bus voltage recovery Blind The functions for the Venetian Blind mode also apply to the Shutter mode (with the exception of the louvre adjustment function).

Function Overview - control Fan speed When bus recovery, fan speed is ON OFF One level Enable forced operation Value of enable forced operation Behavior on forced operation Value of execute auto. Operation Enable Auto. Operation Threshold value OFF < - > ON Hysteresis value Limitation function As fan speed control Function ON/OFF time mode is Switch delay Minimum time Status byte mode Scan and relay operation delay after bus voltage recovery Limit number of send telegrams Response status Fan speed on 2 limit Status ON/OFF mode Status Auto. mode Step switch Fan operation mode Changeover switch When bus recovery, fan speed is Enable output O~Q Multi level Enable forced operation Value of enable forced operation Limitation on forced operation Enable Auto. Operation Switch speed x Enable direct operation Fan speed Up/Down Starting characteristic Fan speed Response status Switch state on bus voltage recovery General switch As relay control Time function Scene function Forced operation

Function Overview HVAC system Scan and relay operation delay after bus voltage recovery Limit number of send telegrams 1 control value/2-pipe Monitoring control values 1 control value/4-pipe with switch obj. Delay time for recovery Auto. Mode Pipe system 2 control value/2-pipe with switch obj. 2 control value/2-pipe 2 control value/4-pipe Operation HEAT/COOL after bus recovery Object value for Toggle HEAT/COOL obj. Valve type HVAC system Valve position after bus recovery Cycle time of the PWM Continuous, PWM Correct valve characteristic curve Enable disable heat/cool object Enable force operation object Heating /cooling Enable valve position status object Enable valve purge Observe reversing time Valve position after bus recovery Valve control time 0%-->100% Automatic adjust valve position 3point, open and close Correct valve characteristic curve Enable disable heat/cool object Enable force operation object Enable valve position status object Enable valve purge

Function Overview Dimming output Reset function Brightness value on bus voltage recovery Switch Preset brightness value Last brightness value Dimming mode Relative dimming Low dimming threshold Upper dimming threshold The output after dim down to <=low dimming threshold Scan and relay operation delay after bus voltage recovery Limit number of send telegrams Absolute dimming Low dimming threshold Upper dimming threshold The output on receipt a brightness value 0 Choose output V, W Scene Output is assigned to (scene 1 64 or no assignment) Staircase lighting mode Duration time of staircase lighting Brightness value for staircase lighting Action after bus voltage recovery Brightness value of staircase lightness at permanent-on Switch status Status response Brightness value

Technical Data Supply Bus voltage 21~30V DC Current consumption, EIB Power consumption, EIB Auxiliary supply Power consumption of Auxiliary <12mA <360mW 100~240V AC <3W supply Power consumption, Output 16A <2W Power consumption, Output 6A <3W Power consumption, dimmer 1A <2W Power consumption, HVAC 1A <1W The max. power consumption of the <11.36W device Connections EIB/KNX Via bus connection terminals(red/black),0.8 mm Ø Outputs, 16A Screw terminals Wire Range 0.5-4mm 2 Torque 0.8N-m The device of the upper Inputs/Output Screw terminals Wire Range 0.5-1.5mm 2 Torque 0.5N-m The device of the lower Inputs/Output (except Output 16A) Screw terminals Wire Range 0.5-2.5mm 2 Torque 0.5N-m Operation/display Programming button/ red LED For assignment of the physical address Green LED flashing The application layer works normally Housing IP 20, EN 60 529 Temperature range Operation -5 +45 Storage Transport -25 +55-25 +70 Ambient conditions Max. air humidity <93%,except dewing

Technical Data Design Housing/colour Modular installation device (MDRC) Plastic housing, grey Installation On 35mm DIN-Rail To EN 60 715 Dimension Weight 90 mm 216 mm 63mm 1KG Input 20 channels Can be individually parameterized per Input ( all inputs are internally connected to the same potential ) U n scanning voltage I n scanning current Permissible cable length 24V DC 0.4mA 10m Output, Dimming 2 channels Can be individually parameterized per Output U n rated voltage I n rated current 100~240 V AC 1A Output, HVAC HEAT Valve and COOL Valve U n rated voltage 85~265 V AC I n rated current 0.5A Output, 16A 4 channels Can be individually parameterized per Output U n rated voltage I n rated current Max. switching current 250/440 V AC(50/60Hz) 16A 20A/250V AC Mechanical endurance >2 10 6 Electrical endurance >10 5 DC current switching capacity (resistive load) 16A/24V DC

Technical Data Output, lamp load 16A Incandescent lamp Fluorescent lamp, not compensated Fluorescent lamp, Parallel compensated Fluorescent lamp, DUO-combination Halogen lamp (230 VAC) Low-voltage halogen lamp with inductive transformer Low-voltage halogen lamp with electronic transformer Mercury arc/sodium discharge lamp not compensated Mercury arc/sodium discharge lamp parallel compensated Dulux lamp, not compensated Dulux lamp, parallel compensated 2500 W 2500W 1500W 1500W 2500W 1200W 1500W 2000W 2000W 1100W 1100 W

Technical Data Output, 6A 13 channels Can be individually parameterized per Output (including switch, shutter and fan) U n rated voltage I n rated current Max. switching current 240/400V AC(50/60Hz) 6A 10A/240V AC Mechanical endurance > 2 x 10 6 Electrical endurance >10 5 DC current switching capacity (resistive load) 8A/30V DC Output, lamp load 6A Incandescent lamp Fluorescent lamp, not compensated Fluorescent lamp, Parallel compensated Fluorescent lamp, DUO-combination Halogen lamp (230 VAC) Low-voltage halogen lamp with inductive transformer Low-voltage halogen lamp with electronic transformer Mercury arc/sodium discharge lamp not compensated Mercury arc/sodium discharge lamp parallel compensated Dulux lamp, not compensated Dulux lamp, parallel compensated 1200 W 800W 300W 350W 1000W 800W 1000W 1000W 800W 800W 800W Note: The above load is only for single lamps. In the case of several lamps in parallel, the load will be reduced, although the power is unchanged, but the instantaneous impact of current will increase, and easy to make the relay contacts melted. So, in normal use, subject to the measured current, the measured maximum inrush current must be within the allowable range.