CASPER: Caratteristiche principali CASPER: Main features



Similar documents
ANALIZZATORI DI COMBUSTIONE COMBUSTION ANALYZERS

Highly efficient flue gas analyzer

Non solo un gruppo digitale: UNA VERA STAZIONE DI LAVORO! Not only a digital manifold: A TRUE WORK-STATION! NEW FOX EVO. Torr mtorr micron inhg

The testo 340 What makes it The Ultimate Combustion Tuner?

Intelligent Motorola Portable Radio Energy System

analog SENSORI INDUTTIVI ANALOGICI inductive analog sensors

Multifunction HVAC and IAQ Meter

INFORMAZIONI GENERALI / GENERAL INFORMATION

SCHEDA TECNICA ESSICCATOI 55/75 55/75 TUMBLE DRYER TECHNICAL DATA SHEET

TERMINAL TACTIL A COLOR CON PLC INTEGRADO Pag 2. TERMINAL TACTIL MONOCROMO CON PLC INTEGRADO Pag 4. PANEL OPERADOR CON PLC INTEGRADO Pag 9

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Daq Link Multi sonda a 4 canali indipendenti

QSLM Dual inlet decompression unit with automatic change-over system FEATURES

Fishtapes and accessories

Serie ET / ET Series

Sassari, Via Fermi, 33 - Tel. 079/

SAFE. DESIGNED in italy CASSEFORTI PER HOTEL HOTEL SAFES

4 IN 5 OUT MATRIX SWITCHER YUV & Stereo Audio

COMPRESSORI D ARIA AIR COMPRESSORS

ELETTRONICA DUE FOTEK. T i p o a t a st e g g i o / Reflex type. T i p o a b a r r i e r a / Thru beam type

LED Power. Power Supplies for constant current HI-POWER LEDs 350/700mA Alimentatori per LED in corrente costante HI-POWER 350/700mA 82206/700

ISOMAG Millennium ML3F1 ESECUZIONE COMPATTA ML3F1 COMPACT EXECUTION

Hand-held thermometer Model CTH7000

NUOVI PRODOTTI NEW PRODUCTS 2015/01

SAFE TOP OPEN. Sistema di chiusura Locking system

EN20 EN50. Double-stage modular decompression unit for oenological application. FEATURES Dual inlet and single outlet decompression unit.

Data Logging Solutions from Lascar Electronics

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

DUAL FUEL BURNERS GAS/HEAVY OIL

POMPE ROTOMEC. ELETTROPOMPE SOMMERGIBILI Submersible pumps. IMPIEGO - Application. DESCRIZIONE - Description. DATI ELETTRICI - Electric data

Raccordi per tubi flessibili Fittings for flexible pipes

RPS. Sanitary sampling valves SAMPLING

Digital inductive conductivity transmitter

CO Low CO High O 2 NO NO 2 NOx SO 2 H 2 S CxHy CO 2 LANCOM III

McSmart 160C. McSmart 160C INDICE / INDEX SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM

MANOMETRI A TUBO DI VETRO GLASS TUBE MANOMETERS

B12 INTERRUTTORI DI PROSSIMITA INDUTTIVI PUSH-PULL STANDARD SERIE SERIES INDUCTIVE PROXIMITY SWITCHES PUSH-PULL STANDARD B12

Measurement Solutions for Refrigeration Technology.

valvole 16 mm ad azionamento pneumatico pneumatically piloted valves - 16 mm

4 vie a pistone con manometri Ø80 classe 1 a secco con vite regolazione

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

PRODUCTS SERIES OL OP 50 OM 50 OL 60 PL 200 GL/TL 500 OP 100 OM 80 OL 80 PL 250 GL/TL 600 OL 150 PL 400

serie FX3 e FX4 - FX3 and FX4 series

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Saldatura e Fusione Soldering and Melting. CANNELLI A GAS PROPANO LIQUIDO GPL Propane Torches. Impugnatura ECON a pistola. Impugnatura CLA a lancia

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Manometri e Termometri. Pressure Gauges and Thermometers

Motori elettrici corrente continua. DC motors MCC

Online Infrared Flue Gas Analyzer Gasboard 3000

Printers and Barcode Scanners

Tools & Equipment Robinair

[ ] Attuatori pneumatici Pneumatic actuators

PRESE -SPINE -CAVI A NORME ISO sockets plugs cables ISO standard

CONDIZIONATORI OUTDOOR

Measuring Instruments for Flue Gas and Emissions

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

PETRA P219 COLOUR MATERIAL Nylon PA A Policarbonato PC SIZE

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

How To Use An Iphone With A Memory Card (I2) For A Week

Test equipment for temperature and its reduction

Contenitori Enclosures

c-pro nano RACK & c-pro micro RACK

CATALOGO 2008 UPGRADE METAFORM

CILINDRI ISO 6432 CYLINDERS ISO 6432

How To Use An Irius Pid Detector

SERIE FX3 e FX4 - FX3 and FX4 SERIES

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

homevideo blu-ray dvd hdv e vhs

Nardalert S3 Non-Ionizing Radiation Monitor

Produktkatalog (GB/IT)

Software Features of Auto Gas Gas Analyzer Features HC, CO, CO2, Lambda, Air Fuel, NOx. Has optional RPM and Oil Temp.

GasAlertMax XT II H 2 O 2 LEL

Measurement data monitoring system

MACCHINA DA CAFFE' AUTOMATICA AUTOMATIC COFFEE MACHINES

Car and commercial cial air conditioning service solutions

E420 SHAFT ALIGNMENT. Entry level measurement and alignment system for rotating machines BUILT-IN WIRELESS UNITS LARGE COLOUR DISPLAY QUICK START

USB-500/600 Series Low-Cost Data Loggers and Accessories

FOTOVOLTAICO AD ISOLA STAND-ALONE PHOTOVOLTAIC KIT

ALIMENTAZIONE POWER SUPPLY

DZ MEDICALE S.r.l. Organismo Notificato n European Notified Body n Reg. No: MED 9913

GRUPPI TRATTAMENTO ARIA FRL GROUPS

Material test chamber with mechanical convection

T-TOP IN ALLUMINIO UNIVERSALI (importazione USA) Adjustable Aluminium T-Top (made in USA)

Mirador. Features include: Applications:

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

13/30 SERIES / SERIE 13/30 EIA 1 5/8 SERIES / SERIE EIA

Freezers - Ultrafreezers. Platilab & Irilab Series

How To Use A Ds340 (Dsp)

CILINDRI SENZA STELO RODLESS CYLINDERS

OT 40L / 90L. Laboratory Steam Sterilizers

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Tubo altissima pressione / Very high pressure hose

Mounting Layout ITALIAN FOG SYSTEMS QUALITY EXPERIENCE.

NoiseMeters. dosebadge. Monitoring Personal Noise Exposure

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

TRI CLAMP PRESSURE REGULATORS

Transcription:

ANALIZZATORI DI COMBUSTIONE - COMBUSTION ANALYZERS CASPER: Caratteristiche principali CASPER: Main features Grande LCD blu retro-illuminato con zoom Large blue backlit LCD display with zoom function Robusto e ben protetto Robust and well protected Bluetooth integrato Bluetooth inside Cuffia con magneti mani libere Holster with magnets hands free App per Android App for Android 12 combustibili (inclusi legna, pellets, biogas e carbone) 12 fuels (including pellets, biogas and coal) Sensore di pressione interno per misura tiraggio fine - UNI 10845 Internal pressure probe for high precision draught measurement - UNI 10845 Stampante termica con connessione Bluetooth Thermal printer Bluetooth connection Sensore Pt100 temperatura aria esterna, da 100 MM. con cavo da 1,8 MT. Outdoor air temperature Pt100 probe with 1,8 MTS cable Sonda prelievo fumi da 180 mm, doppio tubo lungh. 2mt. 180mm flue gas sensor probe, 2mt. double hose 155

Gamma di analizzatori CASPER CASPER Range of combustion analyzers CASPER 201: Kit con analizzatore a 2 celle (O2, CO), non espandibile, senza stampante, con batterie ricaricabili ad ioni di Litio. Misura tiraggio alta precisione secondo UNI 10845. Bluetooth. Gas analyzer kit with 2 sensors (O2, CO), not expandable, no IR thermal printer, with rechargeable Li-Ion batteries. Draught high precision measurement UNI 10845. Bluetooth. D 1450 CASPER 202: Kit con analizzatore a 2 celle (O2, CO), espandibile, senza stampante, con batterie ricaricabili ad ioni di Litio. Misura tiraggio alta precisione secondo UNI 10845. Bluetooth. Prova tenuta UNI 7129/11137. Gas analyzer kit with 2 sensors (O2, CO), expandable, no printer, with rechargeable Li-Ion batteries. Draught high precision measurement UNI 10845. Bluetooth. Gas pipes tightness test UNI 7129/11137. CASPER 201 S: Kit con analizzatore a 2 celle (O2, CO), non espandibile, con stampante Bluetooth e batterie ricaricabili ad ioni di Litio. Misura tiraggio alta precisione secondo UNI 10845. Bluetooth. Gas analyzer kit with 2 sensors (O2, CO), not expandable, with Bluetooth printer and rechargeable Li-Ion batteries. Draught high precision measurement UNI 10845. Bluetooth. D 1700 CASPER 202 S: Kit con analizzatore a 2 celle (O2, CO), espandibile, con stampante Bluetooth e batterie ricaricabili ad ioni di Litio. Misura tiraggio alta precisione secondo UNI 10845. Bluetooth. Prova tenuta UNI 7129/11137. Gas analyzer kit with 2 sensors (O2, CO), expandable, with Bluetooth printer and rechargeable Li-Ion batteries. Draught high precision measurement UNI 10845. Bluetooth. Gas pipes tightness test UNI 7129/11137. CASPER 301: Kit con analizzatore a 3 celle (O2, CO, NO), senza stampante, con batterie ricaricabili ad ioni di Litio. Misura tiraggio alta precisione secondo UNI 10845. Bluetooth. Prova tenuta UNI 7129/11137. Gas analyzer kit with 3 sensors (O2, CO, NO), no printer, with rechargeable Li-Ion batteries. Draught high precision measurement UNI 10845. Bluetooth. Gas pipes tightness test UNI 7129/11137 CASPER 301 S: Kit con analizzatore a 3 celle (O2, CO, NO), con stampante Bluetooth e batterie ricaricabili ad ioni di Litio. Misura tiraggio alta precisione secondo UNI 10845. Bluetooth. Prova tenuta UNI 7129/11137. Gas analyzer kit with 3 sensors (O2, CO, NO), with Bluetooth printer and rechargeable Li-Ion batteries. Draught high precision measurement UNI 10845. Bluetooth. Gas pipes tightness test UNI 7129/11137 AAST01: Stampante termica Bluetooth con carta in poliestere termico inalterabile: 250 AAST01: Bluetooth thermal printer with unerasable polyester paper: 250 Nota: Per gli analizzatori Casper non si applica extra sconto per la permuta con analizzatori usati. Note: For CASPER combustion analyzers there is no extra sale for secondhand combustion analyzers exchange. ANALIZZATORI DI COMBUSTIONE COMBUSTION ANALYZERS 156

ANALIZZATORI DI COMBUSTIONE - COMBUSTION ANALYZERS Tutti i kit contengono: All kits include: Valigia rigida in ABS Alimentatore/carica batterie Sonda prelievo fumi da 180 mm con tubo da 2 m Filtro/trappola anticondensa Sonda aria esterna Pt100 Kit pressione differenziale Custodia in neoprene con magneti Cavetto USB e chiavetta USB Software per PC e video dimostrativo Manuale d uso Certificato di taratura Stampante Bluetooth opzionale 2 celle di misura gas per: Hard ABS case Power supply with plug 180 mm flue gas sampling probe with 2 mts hose Water trap with dust filter Pt100 outdoor air temperature sensor Differential pressure Kit Neoprene holster with magnets USB pendrive and USB connection cable PC software and video manual User manual Calibration certificate Bluetooth printer; optional 2 measuring sensors for: O2 CO NO (solo Casper 301) Altre grandezze misurate: O2 CO NO (Casper 301 Only) Other measurement: Temperatura fumi Temperatura aria esterna Temperatura ambiente Pressione assoluta e pressione differenziale Tiraggio ad alta precisione - UNI 10845 Grandezze calcolate: Flue Gas Temperature Outdoor Air Temperature Room Temperature Absolute and differential pressure Draught high precision measurement - UNI 10845. Measurement: CO2 Rendimento della caldaia, inclusa condensazione Perdite al camino Eccesso d aria Temperatura differenziale Altre prestazioni: CO2 Boiler efficiency, condensing included Stack loss Excess air Differential Temperature Others features: Firmware aggiornabile gratuitamente, scaricabile dal sito www.seitron.it Prova tenuta tubazione gas UNI 7129/11137 (solo Casper 202/301) Firmware updates available for free from Seitron website: www.seitron.it Gas pipes tightness test UNI 7129/11137 (Casper 202/301 only) 157

Principali caratteristiche funzionali: Conforme a EN 50379-1, EN 50379-2 e UNI 10389-1 2 e 3 celle di misura O2, CO, NO Cella CO con risoluzione 1 ppm con filtro per NOX/SOX Sensori Gas precalibrati ed intercambiabili Misura di temperatura fumi ambiente ed esterna Misura di pressione assoluta e differenziale Calcolo del rendimento della caldaia Riconoscimento automatico della caldaia a condensazione e calcolo del rendimento (>100% sul P.C.I.) secondo UNI 10389-1 Calcolo di CO2, perdita al camino, eccesso d aria Misura di CO ambiente Misura del tiraggio ad altissima precisione (± 0,5 Pa) con sensore interno, risoluzione 0,1Pa, secondo UNI 10845 Prova tenuta tubazione gas UNI 7129/11137 (solo Casper 202/301) 3 analisi in sequenza con calcolo automatico della media Memoria per 300 analisi complete Ampio visore LCD grafico (38 x 70mm) retroilluminato, con funzione zoom Batterie ricaricabile ad ioni di Litio Carica batterie/alimentatore esterno Tempo di ricarica: 4 ore al 90% (Sh x 100%) Autonomia strumento: 12 ore di funzionamento continuo Uscita mini USB per collegamento a PC Bluetooth classe 1 (fino a 100 mt) Autodiagnosi con verifica delle funzioni e dello stato dei sensori Sonde prelievo fumi da 180, 300, 750 mm e 1000mm Sonda prelievo fumi flessibile da 300 mm Gruppo filtraggio e anti condensa esterno Connettori infrangibili in AISI 316 12 combustibili preprogrammati, inclusi Pellet, Legno e Biogas Possibilità di arrivare a 32 combustibili 10 lingue preprogrammate Guscio di protezione in neoprene con magneti Chiavetta USB con video dimostrativo e software di collegamento con PC Manuale d istruzione e certificato di taratura Dimensioni A220 x L110 x P55 mm, peso 0,55 KG Connessione Bluetooth a stampante e PC Connessione IR per stampanti IR Main features: Compliant with EN 50379-1 and EN 50379-2 2 and 3 measurement cells O2, CO and NO CO measurement cell with 1 ppm resolution and built in NOX/SOX filter Precalibrated gas sensors, field replaceable Flue gas and outdoor air temperature measurement Absolute and differential pressure measurement Boiler efficiency calculation Automatic detection of condensing boiler with efficiency calculation CO2, heat stack loss, excess air calculation Ambient CO measurement High accuracy internal probe (± 0.5 Pa) and resolution (0.1 Pa) draft measurement with internal sensor Gas pipes tightness test UNI 7129/11137 (Casper 202/301 only) 3 consecutive analysis with average calculation Internal memory for 300 analysis Big blue (38 x 70 mm) graphic LCD backlit with zoom feature Rechargeable Lithium Ion batteries External Charger/Power Supply with AC plug Recharging time: 4 hrs. up to 90% (Sh x 100%) Up to 12 hrs. autonomy of continuous operation USB cable for unlimited data storage on PC Bluetooth class 1 (up to 100 mts) Self diagnostic function with alarms on gas sensors end-of-life 180, 300, 750 and 1000 mm flue gas sensor probes 300 mm flexible flue gas sensors sampling probe External condensation trap and dust filter Unbreakable stainless steel probe and hose connections 12 preprogrammed fuels, including pellets, wood and Biogas 32 additional programmable fuels 10 different languages preprogrammed Neoprene magnetic holster PC software and video manual on USB pendrive User manual and calibration certificate Dimensions H220 x W110 x D55 mm, weight 0,55 Kg. Bluetooth connection to printer and PC IR connection to IR printer ANALIZZATORI DI COMBUSTIONE COMBUSTION ANALYZERS 158

ANALIZZATORI DI COMBUSTIONE - COMBUSTION ANALYZERS PRINCIPALI CONFIGURAZIONI CASPER CASPER MAIN CONFIGURATIONS SENSORE O 2 O 2 SENSOR SENSORE CO CO SENSOR SENSORE NO NO SENSOR SENSORI PRECALIBRATI SOSTITUIBILI DALL UTENTE PRECALIBRATED SENSORS REPLACED BY THE USER ESPANDIBILE A 3 SENSORI EXPANDABLE TO 3 SENSORS MISURA CO AMBIENTE AMBIENT CO MEASUREMENT 12 COMBUSTIBILI IN MEMORIA (inclusi legna, pellets e carbone) 12 PROGRAMMED FUELS (including wood, pellets and coal) MEMORIA 300 ANALISI MEMORY FOR 300 ANALYSIS SENSORE PRESSIONE INTERNO MISURA TIRAGGIO (UNI 10845) DRAFT MEASUREMENT WITH INTERNAL SENSOR (NORM 10845) PROVA TENUTA IMPIANTI UNI 7129/11137 GAS PIPE TIGHTNESS UNI 7129/11137 KIT MISURA PRESSIONE PRESSURE KIT CONNETTIVITA BLUETOOTH (CLASSE 1, fino a 100 mt.) BLUETOOTH COMMUNICATION (CLASS 1, up to 100 mts.) CONNETTIVITA IR IR COMMUNICATION PORTA USB USB CONNECTION SW PER AGGIORNAMENTI E SCARICO MEMORIA PER PC SW FOR UPDATING AND MEMORY DOWNLOAD FOR PC CERTIFICATO DI TARATURA CALIBRATION CERTIFICATE GARANZIA 2 ANNI WARRANTY 2 YEARS SONDA PRELIEVO FUMI DA 180mm FLUE GAS SENSOR PROBE 180mm SONDA TEMPERATURA ARIA COMBURENTE COMBUSTION AIR TEMPERATURE PROBE STAMPANTE BLUETOOTH CON CARTA POLIESTERE INALTERABILE THERMAL BLUETOOTH PRINTER WITH POLYESTER UNERASABLE PAPER CASPER 201 S CASPER 201 -- 159

CASPER 202 S CASPER 202 CASPER 301 S CASPER 301 ANALIZZATORI DI COMBUSTIONE COMBUSTION ANALYZERS 160

ANALIZZATORI DI COMBUSTIONE - COMBUSTION ANALYZERS ACCESSORI E RICAMBI CASPER - CASPER ACCESSORIES AND SPARE PARTS AACPB07 AARC04 AASA05 Batteria ricaricabile Ni-MH, 6 V, 1800 mah Rechargeable batteries Ni-MH, 6 V, 1800 mah Rotolo carta termica Thermal printing paper roll Sensore Pt100 temperatura aria esterna, da 100 MM. con cavo da 1,8 MT Outdoor air temperature Pt100 probe with 1,8 MTS cable. AACR03 AACSE15 AACSE20 Valigia in plastica rigida Hard plastic kit case Cella elettrochimica intercambiabile per misura di OSSIGENO (O2) Interchangeable 02 gas sensor Cella elettrochimica intercambiabile per misura di MONOSSIDO DI CARBONIO (CO) Interchangeable CO gas sensor AASM05 AAST01 ACST02 Custodia protettiva in neoprene con magneti di fissaggio Rubber holster with magnets Stampante termica con connessione Bluetooth Thermal printer Bluetooth connection Stampante termica a raggi infrarossi. Infrared thermal printer. Nota: per tutti gli altri accessori e pezzi di ricambio del Casper, vedere la sezione Chemist 400 Note: for the other Casper s accessories and spare parts go to Chemist 400 section 161

CARATTERISTICHE TECNICHE CASPER - CASPER TECHNICAL FEATURES PARAMETRO MEASUREMENT ELEMENTO DI MISURA SENSOR CAMPO DI MISURA RANGE RISOLUZIONE RESOLUTION PRECISIONE ACCURACY O2 Sensore elettrochimico Electrochemical sensor 0.. 25.0%vol 0.1%vol ±0.2%vol CO alta immunità H2 CO high immunity H2 Sensore elettrochimico Electrochemical sensor 0.. 8000ppm 1ppm ±20ppm 0.. 400ppm ±5% 401.. 4000ppm ±10% 4001.. 8000ppm CO2 0.. 99.9%vol 0.1%vol -- NO Sensore elettrochimico Electrochemical sensor 0.. 5000ppm 1ppm ±5ppm 0.. 100ppm ±5% 101.. 5000ppm Temperatura aria Air temperature Sensore Pt100 Pt100 sensor -20.0.. 120.0 C 0.1 C ±0.5 C Temperatura fumi Flue gas temperature Sensore TcK TcK sensor -100.0.. 1250.0 C 0.1 C ±0.5 C 0.. 100 C ±0.5% 101.. 1250 C Pressione / Pressure (tiraggio & differenziale/ draught & differential) UNI 10845 Sensore Piezoelettrico Piezoelectric sensor -1000.. 20000Pa ±200Pa 0.1Pa oltre / over 1Pa ±0.5Pa -10.0Pa.. +10.0Pa ±2Pa -200.0.. +200.0Pa ±1% +201.. 20000Pa ±1% -1000Pa.. -201Pa Temperatura differenziale Differential temperature 0.. 1250.0 C 0.1 C -- Indice aria Air index 0.00.. 9.50 0.01 -- Eccesso Aria Excess air 0.. 850% 1% -- Perdita al camino Stack loss 0.0.. 100.0% 0.1% -- Rendimento (condensazione) Efficiency (condensing) Indice di fumo Smoke index Strumento esterno External instrument 0.0.. 120.0% 0.1% -- 0.. 9 ANALIZZATORI DI COMBUSTIONE COMBUSTION ANALYZERS 162