1 M I S U R A T O R I E L E T T R O M A G N E T I C I D I P O R T A T A S E R I E E L E C T R O M A G N E T I C F L O W M E T E R S E R I E S ISOMAG Millennium CONVERTER MODEL M L 3 F 1 CONVERTITORE AD ALTA FREQUENZA DI CAMPIONAMENTO (FINO A 400 MISURE/SECONDO) PER MISURATORI ELETTROMAGNETICI SERIE MILLENNIUM FAST SAMPLING FREQUENCY CONVERTER(UP TO 400 SAMPLES/SECOND) FOR ELECTROMAGNETIC FLOWMETER MILLENNIUM SERIE S ML3F1 ESECUZIONE COMPATTA ML3F1 COMPACT EXECUTION
2 SPECIFICA TECNICA Data Documento 20/02/04 Pagine 2/6 DATI TECNICI / TECHNICAL DATA Materiale Custodia Material Box Dimensioni / Dimension 75 X 140 X 60 mm Classe Di Protezione Protection Rate IP 67 Pressacavi / Cable Gland N 2 PG 11 Temp Amb / Amb. Temperature Uscita Impulsi Frequenza Pulse / Frequency Output Uscita In Corrente Current Output Ingresso Digitale / Digital Input Acciaio inox AISI 304 / Stainless steel AISI C 1250 Hz (standard), 12,5 KHz ( OPTIONAL ), 100mA, 40 Vdc ( OPTIONAL ) 4 20mA RL 800W PASSIVA / passive Funzione programmabile / programmable function Uscite ON-OFF / ON-OFF Outputs 1 o.c. + 1 OPT. (prog. imp./freq./all. ) / (programmable function) Misura Bidirezionale Bi-Directional Valore Di F.S. / FS Value Interfaccia Di Comunicazione Communication Interface Funzione Di Autodiagnosi Diagnostic Funct. Rilevazione Tubo Vuoto Empty Pipe Detect. Separazione Galvanica Galvanic Isolation Memorizzazione Dati Data Storage Presa Programmazione Programming Plug In Funzione Dosaggio Bacth Function Certificazione CE CE Certification Incertezza Della Misura Measurement Tolerance Sì / Yes 0,4 10m/s RS 485 (RS232 Opz. / Opt. ) / Profibus DP ( Opt. ) Sì / Yes Sì / Yes Tutti gli ingressi e le uscite sono separati tra loro e dall alimentazione All the inputs / outputs are galvanically isolated from power supply In mancanza di alimentazione i dati vengono memorizzati in una E-Eprom Eeprom stored measuring values on power failure Presa protetta per collegamento PC o terminale portatile Protected plug in for connection to PC or hand terminal Sì, anche con preset automatico (auto-apprendimento ) Yes, also with auto-preset Strumento certificato CE / Instrument with CE certificate Portata ( volume) = ±0,05% v.l. / Flow rate (volume) = ±0,05% v.l. Out 4/20 ma = ± 0,08 % v.l. Out Frequenza = ± 0,08% v.l. / Frequency Out = ± 0,08% v.l. Ripetibilità / Ripetibility Migliore dello 0,01% / Better than 0,01% Alimentazione / Power Supply VDC
3 SPECIFICA TECNICA Data Documento 20/02/04 Pagine 3/6 DIMENSIONI DI INGOMBRO / OVERALL DIMENSIONS
4 SPECIFICA TECNICA Data Documento 20/02/04 Pagine 4/6 CONNESSIONI ELETTRICHE / ELECTRICAL CONNECTIONS (SOLO CON MODULI DI ESPANSIONE ONLY WITH EXPANSION MODULE) OUT ON/OFF " + "(collector) OUT ON/OFF " - " (emitter) - INPUT ON/OFF + INPUT ON/OFF + - POWER SUPPLY IF02 MT 200 STANDARD DIGITAL OUT STANDARD DIGITAL INPUT 7 (+) 10 K 10 (+) 5/33 Vdc (ON) 0/1,5 Vdc (OFF) 8 (-) 9 (-) DIGITAL OUTPUT ( EXPANSION MODULE ) DIGITAL INPUT ( EXPANSION MODULE ) 5 (+) 2K2 3 (+) 2 2K2 6 (-) 1 4 (-)
5 SPECIFICA TECNICA Data Documento 20/02/04 Pagine 5/6 FUNZIONI DISPONIBILI / AVAILABLE FUNCTIONS 1.SENSOR1.1 ND 1.2 KA 1.3 KL + / E.P.DETECT 1.5 AUTOZ. CAL. 1.6 E.P. CALIBR. SET ND SET KA SET KL ON/OFF 2.SCALE 2.1 FS1 2.2 FS2 2.3 MU.TOT 2.4 IMP 2.5 TPUL 2.6 FRQ 2.7 SW SET FULL SCALE 1 SET FULL SCALE 2 MEASURE UNIT PULSE VALUE DURATION PULSE FULL SCALE FREQ. SPEC. GRAVITY VOLUME UNIT VOLUME UNIT TYPE OF UNIT MISURE UNIT TYPE OF UNIT TYPE OF UNIT DECIMAL TOTALIZER TYPE OF UNIT TIME UNIT MEASURE TIME UNIT MEASURE NUMERIC VALUE NUMERIC VALUE NUMERIC VALUE 3.MEAS. 3.1 T. CONST 3.2 SKIP THR 3.3 PEAK THR 3.4 CUT-OFF 3.5 START THR 3.6 AC LINE FIL 3.7 AUTOCAL. TIME CONTANT SET ACC. THRESHOLD PICK CUT THRES. LOW FLOW ZERO TIMING THRES. POWER SUP. FIL. AUTOCALIB 4.ALARM 4.1 MAX THR 4.2 MIN THR 4.3 HYST 4.4 E.P. THR 4.5 ma VAL.FAULT 4.6 Hz VAL.FAULT MAX FLOW ALARM MIN FLOW ALARM HYSTERESIS TH. E. P. THRESHOLD 4/20 ma ALARM SET FREQUENCY ALARM 5.INPUT 5.1 T1 RESET 5.2 T2 RESET 5.3 COUNT LOCK 5.4 CALIBRATION 5.5 RANGE CHANGE 5.6 BATCH 5.7 INPUT 2 EN. RESET OF TOT.1 EN. RESET OF TOT.2 LOCK TOTALISER AUTOZERO CAL. EXT. RANGE CHANGE EXT BATCH ST./STOP EXT FUNCTION INPUT 2 FUNCTION ACTIVE WITH INPUT IN VOLTAGE FUNCTION ACTIVE WITH INPUT IN VOLTAGE 6.OUTPUT 6.1 OUT OUT.2 (OPT.) 6.3 DUTY CYCLE 6.4 OUT.MA1 SEE THE TAB REFER TO THE FUNCTIONS FOR OUTPUTS : MENU 6 "OUTPUT" 7. COMM. 7.1 ADDRESS 7.2 SPEED NETWORK ADDRESS RS485 SPEED 8. DISPLAY 8.1 LANGUAGE 8.2 TOTALIZ. 8.3 DISP. FR. TOT. DISPLAY MODE REFRESH DISPLAY 9.BATCH 9.1 N. SAMPLES 9.2 DIFF.THR 9.3 V.COM 9.4 V. PRE 9.5 AUTO BATCH 9.6 BM AUTO SEL 9.7 CONS. MODE SAMPLES V. COMP. %LIMIT.COMP.VAL. COMP. VAL. PRE-BATCH VALUE AUTO BATCH FORMULA AUTO-SEL. CONS. ST. BATCH 10.DIAGN CALIBRATION 10.2 SELFTEST 10.3 SIMULATION ENABLE CALIB. METER AUTOTEST FLOW SIMULATION 11.INT.DAT 11.1 L2 KEYCODE 11.2 LOAD FACT LOAD USER 11.4SAVE AS USER LEVEL 2 CODE FACTORY RECALL USER RECALL USER VALUE SAVE 3.8 ATORANGE AUTO SCALE 3.9 E. SAVING ENER. SAVING
6 SPECIFICA TECNICA Data Documento 20/02/04 Pagine 6/6 COME ORDINARE / HOW ORDER SENSORE / SENSOR ML 3F1 Display A Versione cieca (senza display e senza tastiera di programmazione) / Blind execution (without display and programming keys) Materiale custodia convertitore - Classe di protezione / Housing material - Protection rate 1 Custodia in Acc.Inox AISI304, classe di protezione IP67 / AISI304 Stainless Steel housing, protection rate IP67 Versione / Version A Versione compatta, con sensore MS... (massima temperatura del liquido 130 C) / Compact version with sensor MS... (liquid maximum temperature 130 C) B Versione separata, accessori in Aisi 304, max distanza 1 m / Separate version with Aisi 304 accessories, max distance 1 m Moduli aggiuntivi / Additional module 0 senza moduli aggiuntivi / Without additional module 1 ME31 :2 out on/off alta frequenza ( Hz ) + n 1 inp. On/off / ME 31 : 2 out on/off high frequency ( Hz ) 2 ME32 : out 4/20 / ME 32 : out 4/20 3 modulo di comunicazione : Profibus PA/ in preparazione / Profibus PA module /under preparation 4 ME 34 modulo di comunicazione : Profibus DP / ME 32 : Profibus DP module 5 ME 33 : modulo di comunicazione : RS 485 / ME 33 : RS 485 communication module ML 3F1 A 1 A 0 ATTENZIONE/WARNING I DATI POSSONO CAMBIARE SENZA ALCUN PREAVVISO/THE ABOVE DATA CAN BE CHANGED WITHOUT NOTICE
ISOMAG Millennium UC 250 VERSIONE A PARETE UC 250 WALL VERSION UC 250 A QUADRO UC 250 PANEL MOUNTING VERSI ON
M I S U R A T O R I E L E T T R O M A G N E T I C I D I P O R T A T A S E R I E E L E C T R O M A G N E T I C F L O W M E T E R S E R I E S ISOMAG Millennium C O N V E R T E R M O D E L MUC 2 5 0 CONVERTITORE
THERMAL ENERGY METER MC 108/ET
USCITE CONTATORE DI CALORE CONVERTITORE SENSORE ELETTROMAGN. EUROMAG CONTATORE DI ENERGIA TERMICA PORTATA: SENSORE ELETTROMAGN. uscite: TEMPERATURE: Pt 100 4-20 ma potenza termica 4-20 ma temperatura ta
analog SENSORI INDUTTIVI ANALOGICI inductive analog sensors
Sensori di prossimità induttivi con uscita analogica Inductive proximity sensors with analogue output a Caratteristiche principali Main features > Ampia scelta di dimensioni: M, M2 e M > Wide choice of
Serie ET / ET Series
Sensori di prossimità induttivi con campo di temperatura di lavoro esteso Extended working temperature range proximity inductive sensors Corpo in acciaio inox / stainless steel housing Modelli M12, M18
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
LED Power. Power Supplies for constant current HI-POWER LEDs 350/700mA Alimentatori per LED in corrente costante HI-POWER 350/700mA 82206/700
LED Power The power supplies and accessories showed in this section are designed to achieve the best lighting and long lasting performances for LED fixtures. A particular attention has been dedicated to
LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER
LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER System for flow measurement, data acquisition and transmission for wastewater with long battery life With Long Life Battery Open Channel Flow Meter
Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
B12 INTERRUTTORI DI PROSSIMITA INDUTTIVI PUSH-PULL STANDARD SERIE SERIES INDUCTIVE PROXIMITY SWITCHES PUSH-PULL STANDARD B12
INTERRUTTORI DI PROSSIMITA INDUTTIVI PUSH-PULL STANDARD SERIE SERIES B12 INDUCTIVE PROXIMITY SWITCHES PUSH-PULL STANDARD INTERRUTTORI DI PROSSIMITA INDUTTIVI CON ELETTRONICA PUSH-PULL STANDARD INDUCTIVE
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
ISOIL ML110 CONVERTER For use with ELECTROMAGNETIC FLOWMETERS
ISOIL ML110 CONVERTER For use with ELECTROMAGNETIC FLOWMETERS 1 2 ML110 CONVERTER MANUAL Including Installation Instructions for M/MS SERIES ELECTROMAGNETIC FLOWMETERS March 2005 VER 3.0x ML 110 - Version
Energy Management Power Analyzer Type WM14-96 Basic Version
Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer
Relative and absolute pressure switch type 529
Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Series DFMT Digital Paddlewheel Flowmeter
Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous
Sensori induttivi conformi alle norme DIN 19234 CENELEC EN 50014-EN 50020 NAMUR (3) CARATTERISTICHE FEATURES. 2mm 3 24 Vdc 10%
Interruttori di prossimità induttivi NON MPLIFICTI NMUR Sensori induttivi conformi alle norme DIN 34 TIPI - TYPES Ø 6,5 Ø 6,5 Ø 6,5 Ø8 Ø8 Ø6,5 Ø6,5 Ø6,5 M8x1 M8x1 NMUR SW13 SW13 CRTTERISTICHE FETURES Schermato
Short information Parameters are programmed via front-side membrane keypad
Digital remote display for Flow Meter DM /DE Universal meter UZ Indication of the quantity consumed in m³ Features LED-Display 14.2mm red Indicating range -99999... 999999 0... 3 Decimal points programmable
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
serie FX3 e FX4 - FX3 and FX4 series
serie FX3 e FX 26-0-200 10:08 Pagina 1 SOMMARIO - INDEX AMPLIFICATORE PER FIBRA OTTICA DA GUIDA DIN SERIE FX3 E FX FIBER-OPTIC AMPLIFIER FOR DIN RAILS FX3 AND FX SERIES Elenco delle caratteristiche funzionali
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
Anelli Rings (1) (1) (2) (2) (3) TIPI - TYPES CARATTERISTICHE FEATURES. 1mm 3 24Vdc 10 30Vdc 10 30Vdc 10% 10% 200 ma.
Interruttori di prossimità induttivi D NELLO Negli interruttori di prossimità ad anello il rilevamento avviene all interno dell anello stesso. Il campo di azione è regolabile mediante vite potenziometrica.
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
SITRANS F M MAGFLO. Electromagnetic flowmeters Signal converter types MAG 5000, MAG 6000. Manual *083R9141* Order no.
s Manual SITRANS F M MAGFLO Electromagnetic flowmeters Signal converter types MAG 5000, MAG 6000 [ ] Order no.: FDK:521H0739 DKFD.PS.027.Z4.02 - A5E00253213 *083R9141* 1. Technical data 1.1 Signal converter
Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0
The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]
Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
DS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
photoelectric highlights www.automation.datalogic.com
photoelectric miniature sensors S8 series The new S8 series of compact sensors offers excellent detection performances, usually associated with sensors that have larger dimensions and a higher price. The
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the
c-pro nano RACK & c-pro micro RACK
c-pro nano RACK & c-pro micro RACK Controllers for compressor racks Controllori per centrali frigorifere c-pro nano RACK and c-pro micro RACK are a range of controllers for the management of compressor
DESCRIPTION DESCRIZIONE
ssptl7r- 04/2014 Cassetta con finecorsa trasmettirore di posizione - Limit switch box position transmitter Disponibile - Available 94/9/EC (ATEX) PTL7 è una cassetta interamente realizzata in Alluminio
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
Alimentatori LED LED drivers
Alimentatori LED LED drivers ALimentatori LED LED drivers Alimentatori disponibili in diverse potenze e dimensioni con caratteristiche tecniche specifiche per settore di utilizzo Alimentatori per applicazioni
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC
HOJA TÉCNICA 1400H101 Edición 01 (02 de 08) www.ako.es GENERAL TECHNICAL SPECIFICATIONS Temperature range: -50ºC to +99ºC type: NTC Total accuracy ( + controller): ±1ºC lead extension with cable AKO-15586:
Preset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
The multi-functional integrator Supercal 531
The multi-functional integrator Supercal 531 Design The Supercal 531 integrator is suitable for connecting Pt 500 or Pt 100 temperature sensor pairs with 2 or 4-conducting wire techniques. Volume inputs
ERMA-Electronic GmbH - Max-Eyth-Str.8-78194 Immendingen - Tel: +49(0)7462/2000-0 - Fax: +49(0)7462/2000-29. Technische Änderungen vorbehalten
Panel mounting instruments / DIN cabinets mounting different standard housing sizes different supply voltages all usual measured variables Measuring instruments programmable industrialfair execution customized
SHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
020-inox 025-inox 040-inox 050-inox 070-inox 080-inox Elettropompe autoadescanti / Self-priming electric pumps
080-inox 070-inox 050-inox 020-inox DESCRIZIONE E APPLICAZIONI Elettropope autoadescanti in acciaio inox AISI 316 ad anello liquido laterale largaente utilizzate nei settori nautico, agricolo ed industriale
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
PRESSACAVI CABLE GLANDS
CTLOGO GENERLE / GENERL CTLOGUE PRESSCVI CLE GLNDS SERIE SERIES PGIN PGE 8.1 PRESSCVI STGNI PER CVO RMTO P-PE-PS 8-2 SEMPLICE TENUT WTER-DUSTPROO CLE GLND OR RMOURED CLE 8.2 PRESSCVI STGNI PER CVO RMTO
QSLM 2000. Dual inlet decompression unit with automatic change-over system FEATURES
Strada dei Boschi, 40 20852 Villasanta (MB) Italia tel. +39 039 302035 [email protected] www.idinsertdeal.com QSLM 2000 Dual inlet decompression unit with automatic change-over system FEATURES It allows
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
BLACKLIGHT RADIANT HEATER BLACKLIGHT TECNOLOGIA RADIANTE
BLACKLIGHT BLACKLIGHT RADIANT HEATER BLACKLIGHT TECNOLOGIA RADIANTE A new experience in heating A new sensation of a soft & expanded warming A pleasant heating all day long A discreet presence, without
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
API Marine. BMS Presentation. Ballast Measurement Systems
API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
INTERRUTTORI DI PROSSIMITA INDUTTIVI IN MINIATURA INDUCTIVE PROXIMITY SWITCHES MINIATURE SERIES
INTERRUTTORI DI PROSSIMITA INDUTTIVI IN MINIATURA SERIE SERIES MA INDUCTIVE PROXIMITY SWITCHES MINIATURE SERIES INTERRUTTORI DI PROSSIMITA INDUTTIVI IN MINIATURA INDUCTIVE PROXIMITY SWITCHES MINIATURE
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Temperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
SERIE FX3 e FX4 - FX3 and FX4 SERIES
SERIE FX3 e FX - FX3 and FX SERIES SERIE FX3 e FX - FX3 AND FX SERIES SOMMARIO - INDEX AMPLIFICATORE PER FIBRA OTTICA DA GUIDA DIN SERIE FX3 E FX FIBER-OPTIC AMPLIFIER FOR DIN RAILS FX3 AND FX SERIES Elenco
M-Bus-Logger Data Logger
Data Logger User Manual Doc.-No.: E102312514074 Bär Industrie-Elektronik GmbH Rathsbergstr. 23 D-90411 Nürnberg Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright
TERMINAL TACTIL A COLOR CON PLC INTEGRADO Pag 2. TERMINAL TACTIL MONOCROMO CON PLC INTEGRADO Pag 4. PANEL OPERADOR CON PLC INTEGRADO Pag 9
TERMINAL TACTIL A COLOR CON PLC INTEGRADO Pag 2 TERMINAL TACTIL MONOCROMO CON PLC INTEGRADO Pag 4 PANEL GRAFICO CON PLC INTEGRADO Pag 6 PANEL OPERADOR CON PLC INTEGRADO Pag 9 PLC FONDO PANEL CON DISPLAY
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
How To Prevent A Forklift From Tipping
The device "SSR-200" is a tool to implement security and agricultural machinery operators against the risk of tipping as a result of traveling on land too steep / inclined. Moreover, in case of actual
MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B0875-2.1 en
MP85 / MP85DP Data sheet MP85 MP85DP Special features - 100% quality control of the production process - Universal twin-channel amplifier for many of the usual market sensors - Powerful algorithms for
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
AMTRON E-30 Compact heat and cooling meter
AMTRON E-30 Compact heat and cooling meter Application The compact AMTRON E-30 meter is used for energy consumption measurements for heating and cooling applications in small premises such as apartments,
80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
IP66. Apparecchio a incasso calpestabile per interni ed esterni. Walk over recessed fixture for indoor and outdoor applications
A L P H A Apparecchio a incasso calpestabile per interni ed esterni Applicazione: pavimentazioni, facciate, alberi di piccola e media dimensione, controsoffitti, vetrine Ambientazione: porticati, passeggiate,
3 3RG78 45 program overview
Overview RG78 45 light curtains and arrays with integrated processing unit for type 4 in accordance with IEC/EN 61496 With "Standard" function package Resolutions: 14, 0, 50, and 90 Protective zone height:
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
Inductive Proximity Sensors
M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12
Series 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.
ISO-9001:2000 certified EE300 Series Electromechanical Inventory Level Measuring System Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION OPERATING PRINCIPLE The EE300 series level measuring system is a
Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table
Version MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearity % meas. range ±0.3 - Max. hysteresis 0.1 - Resolution bit 12 - Max. repeatability 0.1 - Sample rate fast mode khz (5) - Sample
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
Features. Picture. Specifications
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
SITRANS F flowmeters SITRANS FUS080. SITRANS FUS380/FUE380/SONOCAL 3000 4/179. flow sensor pipe, 4 transducers/transducer cables and a transmitter
Overview SITRANS FUS380 flow sensor pipe, transducers/transducer cables and a transmitter SITRANS FUS080. The unit is available in a compact or a remote version with up to 30 meter distance from flowmeter
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
Manual K 100 PR K 100 W PR. Measuring and control instruments for ph and ORP measurements. 7.02 ph 25.0 C S1 S2 Auto. 7.02 ph 25.
Manual K 100 PR K 100 W PR Measuring and control instruments for ph and ORP measurements 702 ph 250 C S1 S2 Auto 702 ph 250 C S1 S2 Auto Dr A Kuntze Gutes Wasser mit System Dr A Kuntze GmbH Robert-Bosch-Str
OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system
Sistema autolimpiable Dissolved Oxygen Autoclean system Applications: - water treatment - activated sludge - de-nitrification - fish pond Install & forget For special applications, the D.O monitor can
INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK
Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: [email protected] INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP
4 IN 5 OUT MATRIX SWITCHER YUV & Stereo Audio
MX44B3 4 IN 5 OUT MATRIX SWITCHER YUV & Stereo Audio FRONT PANEL (MOD. MX44B3ABSLR) CARATTERISTICHE GENERALI - Pannello di controllo professionale a pulsanti diretti I/O di commutazione - LCD per una visione
RAINCONTROL LCD Special
RAINCONTROL LCD Special edition 1.1 01/2007 - code 5880 1/16 RAINCONTROL LCD SPECIAL... 3 RAINCONTROL SPECIAL LCD PANEL PRESENTATION... 4 AUTO... 5 LOW AND HIGH THRESHOLD SETTING... 6 LOW THRESHOLD...
HYDRUS ULTRASONIC METER
HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface