Powervar Series 3200 High Performance Three Phase UPS (10 40 kva)

Similar documents
LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

Line Reactors and AC Drives

UPS Applications and VRLA Battery Sizing

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

4.0 UPS dedicated to ICT for unmatched energy savings

TOSHIBA G /100/160/225 kva

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Phase Modular Finally the benefits of Modular ups are for all

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Installation and Operation Back-UPS 1250, 1300, 1500

DC GROUND FAULT DETECTION PROVIDED FOR UNINTERRUPTIBLE POWER SUPPLIES

ELECTRONIC POWER SYSTEMS

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

TIG INVERTER INSTRUCTION MANUAL

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Thyristor-controlled power supplies and battery chargers

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Considering the effects of UPS operation with leading power factor loads

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

Eaton 93PM UPS Where aesthetics meet intelligence.

SECTION VARIABLE FREQUENCY DRIVES

Specification CyberWave UPS Ver /01/00

Fronius IG Plus. The next generation grid-connected PV inverter

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

Uninterruptible Power Supply

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

12 Things Facility Managers Need to Know About Critical Power System Installation

7-41 POWER FACTOR CORRECTION

SECTION STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

Solution Analysis White Paper CHOOSING THE RIGHT UPS FOR SMALL AND MIDSIZE DATA CENTERS: A COST AND RELIABILITY COMPARISON

LAP ENERGIA PARA DATACENTERS

RIELLO ELETTRONICA. Master HP

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

Galaxy VM. Three-phase power protection. schneider-electric.com

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Back-UPS Pro 1300/1500 Installation and Operation

TLE Series UPS kw for best-in-class multi-mode operating efficiency

SG Series UPS kva three phase 400 Vac

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

Understand Hybrid Generator Battery Systems

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

Understanding Delta Conversion Online "Output Power Factor Ratings" - Part 7

Specifying a Variable Frequency Drive s

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

ABB PSPS Erich Steinmann; Generator control-2013

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Specification Requirements DBL 700MX and 1000MX Series UPS

Power Quality. Uninterruptible Power Supply

Satcon Solstice 100 kw System Solution

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

4KVA/5KVA Parallel Installation Guide

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

User s Manual Before using the inverter, you need to read and save the safety instructions.

12 Volt 30 Amp Digital Solar Charge Controller

Executive Summary. Technical Description

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

MAJORSINE Power Inverter

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

TLE Series. Product Description kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

MODEL 2202IQ (1991-MSRP $549.00)

SSPI-APPN OTES: PARALLEL C ONNECTIONS

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

Inverter / Charger Installation General Operations and AC and DC Connections

A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

Working definitions of terms: Commercial vs. Industrial UPS Systems:

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

Transcription:

Powervar Series 3200 High Performance Three Phase UPS (10 40 kva) Selecting, Specifying and Installation Information Thomas E. Wilson, PE Wilson Engineered Systems, Inc. Jacksonville, FL 32258 904-880-0118 www.wilsonengineered.com

Powervar Series 3200 Introduction Powervar was founded in 1986 and is based in Illinois with a single focus on providing clean reliable power on a world-wide basis with over 600 products ranging from ½ amp through 300 kva. Powervar has been best known in the medical and point of sale application area for power conditioning and backup. They received the 2013 Frost & Sullivan Award for Best Practices referencing global Healthcare and UPS systems. Point of Sale and Healthcare are very demanding power quality environments due to the distributed nature of POS and the inrush demands of healthcare imaging and lab equipment. With the 3200 Series Powervar has brought their demanding standards to the three phase IT market. The 3200 Series was developed to include performance features which have been value engineered out of many manufacturers current UPS systems including: Easy to Understand Color Graphical LCD Display Matched IGBT Rectifier/converter and IGBT Inverter 0.9 Output Power Factor Rating Input Current THD < 2% Output THD < 1% Wide +/- 15% Input Voltage Acceptability 7.5 to 15 khz Switching Control Allowing High Spec Performance 100% Step load Capability w/o Battery Use 300% Overload Capability for 10 Seconds Generator Compatibility at 1:1 (Generator kw: UPS kva) Automatic Input Current Walk-in Control Automatic Restart after Battery Depletion Standard Alarm Contacts Internal DC Disconnect Internal Wrap Around Maintenance Bypass REPO Input Battery Self Test Battery Temperature Monitoring in each Compartment Network Connectivity Internal and External Battery Options Small Footprint Factory Test Report Included with Unit Two Year Warranty

Powervar Series 3200 Power Topology Below is a simplified topology of the UPS internal power path. Many UPS in this size are advertised as IGBT transistor based but typically that is only the inverter. The 3200 Series also uses a matched transistorized circuit for the rectifier and thus is a rabbit rabbit matched design, others are a turtle rabbit design and the mismatch exposes the design to significant battery overuse during normal operations. That is because a turtle rectifier cannot keep up with a rabbit inverter, causing the battery to assist when the turtle can t react fast enough. Internal Maintenance Bypass Static Switch Bypass Input Output IGBT Rectifier IGBT Inverter Batteries These new UPS modules are lighter, designed for simple single input wiring and are optimized at 120/208 VAC, 3 wire plus ground for additional wiring and installation cost savings. Selection, planning and installation of a UPS system should be easy, yet often it is not. This booklet and the Powervar layout are designed to restore simplicity. Warranty for the UPS is standard at two years with options for longer. As customers deserve assured reliability Wilson Engineered Systems includes a UPS/Battery PM in each year of the warranty at no charge for local customers.

Benefits High Performance: The IGBT s used in the rectifier and inverter sections are matched technology that allows fast response to changing loads and high demand harmonic type loads. The benefit is peace of mind that its design can carry virtually any foreseeable load placed on it. Battery Life Extension: The UPS batteries are charged via the IGBTs in the rectifier with their high frequency control. This provides for cleaner DC Charging voltage when compared to diode bridge and SCR rectifiers which in essence allow the batteries to see utility variations directly. Those DC bus variations are ripple that the batteries must endure. Ripple raises battery internal temperatures and reduces battery life. The Powervar configuration is soft on batteries and this UPS continues the concept. Additionally a battery test control circuit routinely tests the battery string(s) for failure. The benefit is extended battery life and less frequent battery replacements. Generator Friendly: Most UPS manufacturers use 6 or 12 pulse SCR rectifiers to convert AC power to DC on the front end of the UPS. That is a highly distorted 1970 s methodology. To reduce the distortion, they incorporate capacitor based filters which need high cost capacitor change out every 5 years. The filters do make these types of UPS friendlier to generators when heavily loaded. However, at light load the capacitors create problems for generators and UPS manufacturers have to add more components to switch the capacitors out of the circuit at lighter UPS loads. All very complicated and the generator still sees high distortion at light loads. The IGBT rectifier is state of the art and provides for clean, sinusoidal current draw without needing capacitors. This is done by high frequency transistor control permitting the UPS to control its current draw very finely at all load points. The UPS requires only 1 kw of generator for each kva of UPS power. Traditional UPS designs with 6 and 12 pulse rectifiers can require the generator to be sized as high as 2.5 kw per kva of UPS! The benefit is more reliable generator operation and dollars savings due to smaller generators. Space and Weight Savings: The 3200 Series UPS has been designed physically smaller and lighter than past UPS. Space and weight savings are always a benefit. Reduced Air Conditioning: The 3200 Series technology will reduce the air conditioning need. The benefit is upfront savings on air conditioning first cost followed by years of savings in operating cost. Low Cost Operation: The UPS operates at lower operating cost than many other UPS. The bottom line cost of IT operations being reduced allows precious IT or facilities operating budget dollars to be spent or saved for better corporate benefit.

Warranty/Service The 3200 Series UPS comes with a two year warranty. In short, the warranty covers parts, labor and travel for 24 months from shipment of the UPS. This covers the UPS and battery for defects. Preventative Maintenance Programs are available during the warranty and post warranty. These are listed in the Preventative Maintenance Programs portion of this document. Wilson Engineered Systems is a fully trained Authorized Service Provider (ASP) for multiple UPS manufacturers. Wilson Engineered Systems was awarded the top ASP in the Southeast United States for Toshiba in the fiscal 2009/2010 year. As there are approximately 100 service locations in the US this is a high honor to be singled out for the award and it verifies the priority Wilson Engineered Systems places on customer support.

10 kva/ 9 kw and 20 kva/ 18 kw UPS Dimensions Cable Entry: Bottom Preferred, Side Available Connections: Recommend flex to allow UPS to roll forward 36 Dimensions/Weight: 18 w x 34 d x 48 h, 10 kva - 600 lbs., 20 kva -700 lbs. Color: Black Clearances: 36 Front, 12 Rear, 6 Left and Right Side Typical Lead Time: Stock Available Options Add-On Battery Cabinets: 18 w x 34 d x 48 h, weight varies with run time (from 550 to 1,900 lbs, each) Matching External Bypass: 24 w x 34 d x 48 h Wall Mount External Bypass: 24 w x 9 d x 38 h 480 V Transformer Cabinet: 30 w x 34 d x 48 h. 500 lbs

UPS Modules 30 kva/ 27 kw and 40 kva/ 32 kw UPS (28.8 also*) Cable Entry: Bottom Preferred, Side Available Connections: Recommend flex to allow UPS to roll forward 36 Dimensions/Weight: 23.2 w x 33.71 d x 47.93 h, 30 & 40 kva - 1,050 lbs. Color: Black Clearances: 36 Front, 12 Rear, 6 Left and Right Side Typical Lead Time: Stock Available Options Add-On Battery Cabinets: 29 w x 34 d x 60 h, weight varies with run time (from 875 to 2,500 lbs, each) Matching External Bypass: 3 w x 34 d x 48 h Wall Mount External Bypass: 30 w x 12 d x 43 h 480 V Transformer Cabinet: 30 w x 34 d x 60 h. 650 lbs *Note: 28.8 kva offering is a derated 30 kva to use on 100A circuit feeds as many feed panels allow only up to a 100A breaker to fit. The 28.8 kva rating allows the maximum power from a 100A breaker per code.

Typical System Configuration - One Line Drawings Below is standard configuration #1. This is the simplest, lowest cost configuration. This configuration and relies upon the internal maintenance bypass for service. Configuration #2 below adds an external maintenance bypass circuit which assures service or testing may be performed without effect upon the load. It is the safest and recommended installation configuration.

Installation Planning Based upon 208 volt application the following apply. kva kw Nominal Input Amps Input Breaker Output Amps Min Output Breaker Max Battery Current Approx. Heat Output 10 9 28.4 40 28 35 27.1 3.8 kbtu/hr 20 18 56.7 80 55.5 70 54.2 7.6 kbtu/hr 28.8 23 70.9 100 79.9 100 69.3 7.8 kbtu/hr 30 27 83.2 125 83.3 110 81.4 9.1 kbtu/hr 40 36 110.9 150 112 150 108.5 12.2 kbtu/hr Wall Mount Maintenance Bypass Section We recommend all UPS systems be installed with a true maintenance bypass circuit. An external maintenance bypass circuit allows any type of service or replacement to be performed on the UPS system without requiring a critical load shutdown. It is not an expensive option and is extremely valuable when needed.. Module Size (kva) Input Breaker Bypass & Output Breaker Dimensions W x D x H (inches) 10 40 A 35 A 24 x 9 x 38 20 80 A 70 A 24 x 9 x 38 28.8 100 A 100 A 24 x 9 x 38.7 30 125 A 110 A 30 x 12 x 42 40 150 A 150 A 30 x 12 x 42

Battery Cabinet Options There is a wide range of battery options available for the UPS. The most common selection is VRLA batteries in cabinets. Additional battery predictive health monitoring is available where each battery is individually monitored for both voltage and impedance. Each battery cabinet contains a battery circuit breaker to allow isolating the battery cabinet for service. Battery Reserve Time is generally recommended to be 5 minutes minimum even when a generator is involved. This is to ensure battery support as the batteries age and minimize high DC current for a given application. Maximum battery time is only limited by physical constraints of size, weight and wiring capability. In initially selecting a battery consider the following. 1. Batteries are the weakest point in a UPS system. N+1 Redundancy of battery cabinets should be considered for high reliability needs. Automated individual battery health monitoring, described later within this document, will enhance system reliability. Use of the charts simplifies knowing how much battery time will remain if one battery cabinet is out for service or failure. 2. When designing for N+1 battery cabinet reliability, be sure that desire is known and considered in the battery breaker sizing as standard manufacturer policies typically do not plan for related battery cabinet breaker redundancy. This adds minor cost but must be engineered upfront.

Battery Health Monitoring Wilson Engineered Systems has long been involved in battery health monitoring (since 1993) and the BTECH Impedance/Voltage/Temperature based battery health monitor is an available option with the UPS. BTECH manufactures the only patented online real-time impedance monitor which minimizes the chance of batteries being compromised at the most critical moment. The system is comprised of two principle components: the Battery Validation System (BVS) hardware and Battery Validation Manager (BVM) software. The system provides: Individual unit/cell impedance monitor Pilot unit/cell temperature monitor Individual unit/cell voltage monitor Total voltage monitor String current float and discharge monitor Battery discharge monitor Cycle counter monitor Real-time system monitoring A rise in a battery s impedance signifies diminished battery health. The picture below on the left shows this. The BVM Software trends impedance readings and automatically alerts users. During outages the system tracks individual battery performance as shown on the picture below on the right. The BTECH system continually informs with preemptive data, allowing proactive battery preventative maintenance before disaster can strike. Each system is engineered for the specific battery and UPS application. Users with multiple UPS can run a common software copy to monitor multiple battery systems globally. Impedance rise = failing battery Voltage drop under load = weak battery

Preventative Maintenance Programs Preventative Maintenance Programs are available. Being a high quality, highly reliable UPS does not eliminate benefits of maintenance. With a multi-year warranty some may think to delay service until the warranty has expired. However, warranty is for coverage of factory defects. If misuse, lack of maintenance, environment or other field condition initiates an issue it is very possible warranty would not cover needed service. Proper preventative maintenance is the best assurance of long term reliable operation. We all want to think our facilities are always clean and equipment stays in top notch condition but here are bits of reality. These are real photos of UPS we ve been called in to service. Unfortunately, we have seen these issues at multiple sites. Dusty Control Board Dust Covered Heat Sink Corrosion on Battery Cable UPS are not able to work and provide full design capabilities when conditions like these shown above exist. Dust buildup can create an electrical bridge (short circuit) between control board components, dust covered heat sinks will allow components to overheat. Battery cable corrosion increases DC system impedance and lowers charging capability and discharge performance. All these are easily prevented when equipment is properly and routinely maintained.

Standard service includes: Preventative Maintenance Visit Plans for single visits to inspect, service, clean and calibrate the UPS and batteries. Annual Preventative Maintenance Plans o Level I Basic Plan Two PMs per year (1 st ) UPS and Batteries (2 nd ) Batteries o Level II Recommended Plan Four PMs per year (2) UPS and Batteries (2) Batteries o Level II Custom Plan Configured as desired by customer Battery Replacement Services Visit the Warranty Section of this document for explanation of the warranty and extended warranty options available. Wilson Engineered Systems is a fully trained Authorized Service Provider (ASP) for multiple UPS manufacturers. We are proud of this achievement. Wilson Engineered Systems was awarded top ASP in the Southeast United States for Toshiba 2009. As there are approximately 100 service locations in the US this is a high honor to be singled out for the award and it verifies the priority Wilson Engineered Systems places on customer support.

Who We Are Wilson Engineered Systems is a hybrid IT Infrastructure supply company. Our company is based in Jacksonville, FL and was founded in 1992. Our IT experience dates back to 1981. We design, supply and service the infrastructure supporting IT equipment. As a registered professional engineer based company, we provide sound equipment and design with equipment optimized for this environment. Goal #1 is reliability, followed by economical life cycle costs, usability and serviceability. Our main area of concentration is UPS and overall power delivery systems. We also provide technical furniture, server cabinets, critical monitoring and air conditioning. We offer system design engineering services for all areas and have done so for sites ranging from small server rooms to large 2 mega watt industrial plants. Realizing proper maintenance of critical equipment is paramount to reliability, we also provide full service for equipment we supply.