System pro M compact Miniature circuit breaker S 200 S

Similar documents
System pro M compact Miniature Circuit Breaker S 200/S 200 M

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Analog signal converters CC-E I/I Current / current isolators

R.C.C.B. s two-pole LEXIC

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

5SV Residual Current Protective Devices

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Catalog. Modular DIN rail components Installation contactors

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Manual motor starter MS116

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Catalog Edition DIN-Rail components for rolling stock applications

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Manual Motor Starter MS 116 up to 16 A Technical Data

Pluggable interface relays CR-P Pcb relays

MNS is Switchgear System Technical Overview

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

The complete range of consumer switchboards and switchgear

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

RCD Type F Residual current protection for single phase inverters applications

Technical catalogue. Modular DIN rail components Installation contactors

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

SURGE PROTECTIVE DEVICES

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Type: DILM32 10(24V50HZ) Article No.:

ZS25 Screw Clamp Terminal Blocks Feed-through

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

49 Series - Relay interface modules A. Features

Series 8146/5-V37 and Series 8150/5-V37

Type: DILM9 10(24VDC) Article No.:

CUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH _0_000

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

RY2 miniature industrial relays

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Low Voltage Products. Switches Automatic Transfer Switches

38 Series - Relay interface modules A

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

48 SERIES Relay interface modules 10 A

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

E-STOP relays, safety gate monitors

Thermal-Magnetic Circuit Breaker M1-..

RM4TG20 three-phase network control relay RM4-T - range V

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

38 Series - Relay interface modules A

Thermistor motor protection

Plug and Socket Devices CES 63 A Series 8579

Relés e Contatores de Estado Sólido SIRIUS

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Safety automation solutions

Redundancy Module QUINT-DIODE/40

PSR The compact range Description

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Residual Current Protective Devices

Technicaldata General

HERZ-Thermal Actuators

Contact expansion modules

40 Series - Miniature PCB/Plug-in relays A. Features

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Contact expander modules

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

ABB solutions for photovoltaics Protection and other modular devices

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Bimetallic Overload Relay Specifications

Digital input modules

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Bulletin 1489 Circuit Breakers. Selection Guide

Circuit Breakers. Next Generation of Protection Capabilities

EBS852 (Contrac) Power Electronic Unit

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

picomax The Pluggable Connection System

Transcription:

Data sheet System pro M compact Miniature circuit breaker S 200 S 2CDC021001S0010 2CDC021002S0010 The miniature circuit breaker S 200 S extends the established ABB System pro M compact product range. Thanks to the tool-free screwless terminal technology the S 200 S can be wired far more quickly and easily than standard screw-type circuit breakers. All kinds of cables can be connected. Rigid cables and flexible cables with end sleeves can be plugged in the screwless terminal directly. The easyto-use, smooth-running terminal lever only needs to be pushed to connect flexible cables without end sleeves or to disconnect the wiring. Features Screwless terminal on the load side allows easy, fast and save wiring Cables can be connected and removed without any tools 2 cables up to 4 mm² are directly pluggable Rigid cables and flexible cables with or without end sleeves can be connected Best visibility conditions for the wiring due to the arrangement of the terminal openings Comfortable and exact voltage measurement on the load side due to the easily accessible measurement point Improved terminal on the supply side for cables up to 35 mm² Approved according to IEC/EN 60898-1 for global use Fully compatible with all System pro M compact devices and accessories

Technical data General data Standards IEC/EN 60898-1 Number of poles Tripping characteristics Rated current I n Rated frequency f Data acc. to IEC/EN 60898-1 Rated operational voltage U e Power frequency recovery voltage (U max ) Minimum operational voltage 1P, 3P B, C 6... 20 A 50/60 Hz 1P: 230 V AC; 3P: 400 V AC 1P: 253 V AC; 3P: 440 V AC 12 V AC Rated insulation voltage U i Phase to ground 250 V AC Rated short-circuit capacity I cn Phase to phase Energy limiting class 3 Overvoltage category Pollution degree 2 440 V AC Rated impulse withstand voltage U imp (1.2/50 µs) 4 kv (6.2 kv @ sea level; 5.0 kv @ 2,000 m) Dielectric test voltage 6 ka Reference temperature for tripping characteristics 30 C Electrical endurance Mechanical data III 50/60 Hz, 1 min.: 2 kv 20,000 operations Housing material Insulation group II, RAL 7035 Toggle Contact position indication Degree of protection Mechanical endurance Resistance to shock acc. to IEC/EN 60068-2-27 Resistance to vibrations acc. to IEC/EN 60068-2-6 Insulation group II, black, sealable Marking on toggle (I ON / 0 OFF) IP20, IP40 in enclosure with cover 20,000 operations 25g, 2 shocks, 13 ms 5g, 20 cycles at 5...150...5 Hz with load 0.8 In Environmental conditions acc. to IEC/EN 60068-2-30 28 cycles with 55 C / 90-96% and 25 C / 95-100% Ambient air temperature Operation -25 +55 C Installation Storage -40... +70 C Terminal Line-side Failsafe bi-directional cylinder-lift terminal Load-side Cross-section of conductors Line-side 35 mm² Load-side Cross-section of busbars Line-side 10 mm² Tightening torques Load-side Screwless terminal (2 openings for one cable each) 1... 4 mm² (rigid or flexible wires without end sleeves) 1 2.5 mm² (flexible wires with end sleeves) 2.8 Nm Recommended screw driver Pozidrive 2 Mounting on DIN rail Mounting position Supply Dimensions and weight On DIN rail 35 mm acc. to EN 60715 by fast clip Any Bottom Mounting dimensions acc. DIN 43880 Mounting dimension 1 Pole dimensions (H x D x W) Pole weight Combination with auxiliary elements Auxiliary contact, signal contact, shunt trip, undervoltage release 89.0 x 69.0 x 17.5 mm 0.100 kg Yes 2-2CDC002137D0201

Tripping characteristics, internal resistance and power loss Tripping characteristics B characteristic C characteristic 2CDC022026F0210 2CDC022001F0210 Tripping characteristics acc. to IEC/EN 60898-1 Tripping characteristic Rated current Thermal release 1) Electromagnetic release 2) Currents Tripping time Range of instantaneous tripping Tripping time conventional non-tripping current conventional tripping current I 1 B 6 to 20 A 1.13 I n 1.45 I n > 1 h C 6 to 20 A 1.13 I n I 2 < 1 h 1.45 I n > 1 h < 1 h 3 I n 0.1 45 s 5 I n < 0.1 s 5 I n 0.1 15 s 10 I n < 0.1 s 1) The thermal releases are calibrated to a nominal reference ambient temperature; for B and C the reference value is 30 C. In the case of higher ambient temperatures, the current values fall by approx. 6 % for each 10 K temperature rise. 2) The indicated tripping values of electromagnetic tripping devices apply to a frequency of 50/60 Hz. The thermal release operates independent of frequency. Internal resistance and power loss Tripping characteristic Rated current I n Internal resistance per pole 1) Power loss per pole 1) A mω W B, C 6 52.1 2.16 C 8 22.9 1.65 B, C 10 19.0 2.20 B, C 13 13.7 2.62 B, C 16 9.1 3.28 B, C 20 6.2 3.14 1) Internal resistances and power loss are subject to application-specific and environment-specific conditions and are therefore to be considered as typical values. 2CDC002137D0201-3

Derating For installations of miniature circuit breakers at other temperatures than the reference value and installations of several miniature circuit breakers directly side by side, derating factors have to be considered. Deviating ambient temperature The rated value of the current of a miniature circuit breaker with B and C characteristic refers to a reference ambient temperature of 30 C. The following table contains the derating of the load capability at ambient temperatures from 40 to 70 C for the characteristics B and C. Rated current I n A Maximum operating current at ambient temperature T A 40 C 30 C 20 C 10 C 0 C 10 C 20 C 30 C 40 C 50 C 60 C 70 C 6.0 8.0 7.7 7.5 7.2 6.9 6.6 6.3 6.0 5.7 5.3 4.9 4.5 8.0 10.7 10.3 10.0 9.6 9.2 8.8 8.4 8.0 7.5 7.1 6.5 6.0 10.0 13.3 12.9 12.5 12.0 11.5 11.1 10.5 10.0 9.4 8.8 8.2 7.5 13.0 17.3 16.8 16.2 15.6 15.0 14.4 13.7 13.0 12.3 11.5 10.6 9.7 16.0 21.3 20.7 20.0 19.2 18.5 17.7 16.9 16.0 15.1 14.1 13.1 11.9 20.0 26.7 25.8 24.9 24.0 23.1 22.1 21.1 20.0 18.9 17.6 16.3 14.9 Influence of adjacent devices If several miniature circuit breakers are installed directly side by side with high load on all poles, a correction factor has to be applied to the rated current (see table). If distance pieces are used, the factor is not to be considered. No. of adjacent devices 1 1 2, 3 0.9 4, 5 0.8 Factor F 6 0.75 Example S201S-C16 at T = 40 C Type of use Values to use Calculation Result Load at ambient temperature I n (40 C) I n = 15.1 A Load at ambient temperature with 8 adj. devices I n (40 C), Factor F 15.1 A x 0.75 I n = 11.33 A 4-2CDC002137D0201

Accessories, dimensional drawing and approvals Accessory overview H S/H S/H (H) ST UR OR Auxiliary contact (changeover contact) Signal/auxiliary contact Signal/auxiliary contact used as auxiliary contact Shunt trip Undervoltage release Overvoltage release MOD-S (*) Motor operating device H-L H-R H-BF Auxiliary contact to be mounted on the left Auxiliary contact to be mounted on the right (2 contacts) Auxiliary contact, bottom fitting (1 per pole) 2CDC022032F0211 BP NT Mechanical tripping device Neutral disconnector (*) In case of using S 200 S coupled with DDA 200, MOD-S doesn t operate in case of earth-leakage fault. Dimensional drawing 2CDC022222F0009 Approvals J VDE Germany IMQ KEMA LCIE ÖVE SEV Italy Netherlands France Austria Switzerland 2CDC002137D0201-5

Instructions for use Connection and disconnection of different types of cables on the load side Type of cables and cross sections 2CDC022027F0211 Connection of cables 2CDC022028F0211 Connection of one cable per opening Rigid and flexible cables with end sleeves may be directly connected. If flexible cables without end sleeves are to be connected, the terminal must be opened. Splicing of the wires must be avoided. The cable must be inserted into the terminal either as far as possible or in such a way that a sufficient connection is obvious. The tightness of the connection must be checked. Disconnection of cables 2CDC022029F0211 The cables may only be removed after operating the terminal s opening mechanism. If one cable is removed, the correct position of the remaining cable must be checked. Processing instructions The screwless terminal at the load side of the S 200 S is designed so that copper cables basically may be connected without further preparation. If end sleeves are used as splicing protection for flexible cables, the compression of the end sleeves must comply with the pull-out forces in accordance with standard IEC/EN 60898-1 table J.3. Recommended tools for flexible cables with end sleeves Crimp tool with trapezoid compression profile Wire stripping length / size of end sleeves for all cables Wire stripping length and end sleeve length 12 (+2) mm Distribution boards with metal cover The distance from a metallic cover to the shoulder of the miniature circuit breaker must be at least 6 mm on the load side due to the arrangement of the easily accessible measurement point. 6-2CDC002137D0201

Order data S201S S203S 2CDC021001S0010 2CDC021002S0010 Tripping characteristic Number of poles Rated Type Order code Packing current I n unit A PCE kg Weight per PCE B 1 6 S201S-B6 2CDS251002R0065 10 0.100 10 S201S-B10 2CDS251002R0105 10 0.100 13 S201S-B13 2CDS251002R0135 10 0.100 16 S201S-B16 2CDS251002R0165 10 0.100 20 S201S-B20 2CDS251002R0205 10 0.100 3 6 S203S-B6 2CDS253002R0065 1 0.300 10 S203S-B10 2CDS253002R0105 1 0.300 13 S203S-B13 2CDS253002R0135 1 0.300 16 S203S-B16 2CDS253002R0165 1 0.300 20 S203S-B20 2CDS253002R0205 1 0.300 C 1 6 S201S-C6 2CDS251002R0064 10 0.100 8 S201S-C8 2CDS251002R0084 10 0.100 10 S201S-C10 2CDS251002R0104 10 0.100 13 S201S-C13 2CDS251002R0134 10 0.100 16 S201S-C16 2CDS251002R0164 10 0.100 20 S201S-C20 2CDS251002R0204 10 0.100 3 6 S203S-C6 2CDS253002R0064 1 0.300 8 S203S-C8 2CDS253002R0084 1 0.300 10 S203S-C10 2CDS253002R0104 1 0.300 13 S203S-C13 2CDS253002R0134 1 0.300 16 S203S-C16 2CDS253002R0164 1 0.300 20 S203S-C20 2CDS253002R0204 1 0.300 2CDC002137D0201-7

Contact us ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-Mail: info.desto@de.abb.com You can find the address of your local sales organization on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2011 ABB All rights reserved Order number 2CDC 002 137 D0201 printed in Germany (07/11-5-ZVD)