MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL



Similar documents
MAC-821SC-E. Centralized On-Off Remote Controller INSTALLATIONSMANUAL INSTALLATIONSMANUAL. English. Deutsch. Français. Nederlands. Español.

MAC-399IF-E. M-NET Interface. Model INSTALLATIONSMANUAL INSTALLATIONSMANUAL. English. Deutsch. Français. Nederlands. Español.

Power supply unit Model: PAC-SC50KUA

MAC-333IF-E. SYSTEM CONTROL Interface. Model INSTALLATIONSMANUAL INSTALLATIONSMANUAL. English. Deutsch. Français. Nederlands. Español.

INSTALLATION GUIDE 1

AIR CONDITIONING SYSTEMS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

INSTALLATION MANUAL [FÜR INSTALLATEURE]

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

LIEBERT VNSA Installation Sheet

HP UPS R1500 Generation 3

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

2013 Wireless Video Intercom INSTALLATION GUIDE

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Wall-Mounting your HP computer. User Guide

16/32 Channel 1U Rack Mount CCTV Power Supply

Installation, operation and maintenance manual TX 35A

Floor Type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA. English

HMI display Installation Guide

Advantium 2 Plus Alarm

AIR-CONDITIONER SPLIT TYPE

Nest Learning Thermostat Installation Guide. Installation step-by-step

Product and functional description

User Manual THR840DUK Digital Thermostat

AIR CONDITIONER INSTALLATION MANUAL

COLOR VIDEO DOOR PHONE CDV-71BE/D

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

Model 1756 Test Lead Kit

Drayton Digistat +2RF/+3RF

How To Set Up An Ecm Display On A D210 (D210) (D2) (Ecm) (Emc) (Mcd) (Power Supply) (Mm) (Camellom) (Ios)

TS93 EMR T/PT/TDE. Surface applied door closer

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Bubble King. User Manual

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

BM ADAPTER Model: BAC-HD150

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

HM-W536 Install Guide

Ducoterra Radiant Heating Panel Installation Manual

Portable Air Conditioner

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

MIC-WKT and MIC-WKT-IR

Installation Instructions

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

3 IN 1 BATHROOM HEATER

ADM1TE 5/30A DIN rail single phase two wire energy meter

User Manual. Video Doorphone CDV-1020AQ

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

DALI RC BASIC SO. Control unit Operating instructions

SELF INSTALLATION GUIDE

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English

Manual for Fire Suppression & Methane Detection System

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation & User Manual Radio Remote rev1.0.3

AutoDome Easy II. VEZ Series. Mounting Manual

! WARNING. Before using product, read and understand instructions.

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

Radiant Temperature Sensor TY7321

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS INSTALLATION HANDBOOK

REMOVE AND REPLACE AIR CONDITIONER. 170 Popular Dodge REMOVAL: AIR CONDITIONING Section 4 Page 1

Indoor Remote Controlled Power Points

4P H. Wireless LAN Connecting Adapter <BRP069A41> Installation Manual

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

INSTALLATION INSTRUCTIONS FOR INTERNATIONAL 9000 SERIES ROOF TOP AIR CONDITIONERS

INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

AXIS 291 1U Video Server Rack Installation Guide

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

US Installation Manual Smappee Monitor

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Use and Care Manual. Model CPA12KH AIR CONDITIONER

QUICK REFERENCE. Wired remote controller BRC2E52C7 BRC3E52C7

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

1. BEFORE INSTALLATION

Modular I/O System Analog and Digital Interface Modules

On/Off Relay Switch and 3-Way Switch Kit

T7560A,B,C Digital Wall Module

Transmitter Actuator 230V wave UP 560. Operation

English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. Français. R410A Split Series. Español MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

OPL BASIC. Dosing System for Professional Laundry machines. Contents

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

2 WIRE COLOR. KCV-D372 MANUAL [ 7inch Digital color video phone ] HANDSFREE VIDEOPHONE. Warranty. Warranty Card

Wireless Alarm System. Silent Alert. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

Anthro Tablet Charging Cabinets

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Wall Mounted Mini Split Heat Pump Air Conditioner

CELO5. User & Installation Manual.

Transcription:

Centralized On-Off Remote Controller MC-821SC-E [FOR INSTLLER] INSTLLTION MNUL English [ [ π À À π ] E XEIPI IO O H IøN E KT T H [ [MONTÖR Ç N] MONTJ ELK TBI ÏÏËÓÈÎ [ДЛЯ УСТАНОВИТЕЛЯ] РУКОВОДСТВО ПО УСТАНОВКЕ Русский [ ] [ ]

Caution To use this centralized controller, you must have a M & Contact Terminal Interface (MC-397IF-E, sold separately) for each air conditioner unit. Contents 1. Safety Instructions... 2 2. ccessory... 3 3. Mounting the Centralized Controller/Direct Wiring... 6 4. Mounting the Centralized Controller... 8 5. Test Run... 9 6. Room Name Display... 9 7. Specifications... 9 1. Safety Instructions Read all Safety Instructions before using this device. This manual contains important safety information. Be sure to comply with all instructions. fter installing the controller, provide this Installation Manual to the user. Instruct users to store their room air conditioner Instruction Manual and Warranty in a safe location. Warning (Improper handling may have serious consequences, including injury or death.) Users should not install the centralized controller themselves. Improper installation may result in fire, electric shock, or damage/water leaks if the centralized controller falls. Consult the retailer or specialty store where you purchased the unit for referral to an installer. The centralized controller should be securely installed in accordance with the enclosed Installation Instructions. Improper installation may result in fire, electric shock, or damage/water leaks if the centralized controller falls. The unit should be mounted in a location that can support its weight. If installed in an area that cannot support the unit, the centralized controller could fall and cause damage. Securely attach the electrical component cover to the centralized controller. If the electrical component cover of the centralized controller is not securely attached, dust or water penetration could occur, resulting in a fire or electric shock. Mitsubishi components or other designated components should be used for installation. Improper installation may result in fire, electric shock, or damage/water leaks if the centralized controller falls. When performing electrical work, adhere to the Technical Standards Regarding Electrical Equipment and the Interior Wiring Standards, follow the instructions provided in the Instruction Manual, and be sure to use a dedicated circuit. Inadequate circuit capacity or improper installation could result in a fire or electric shock. 2

2. ccessory Before installing the unit, make sure that you have all the necessary parts. Centralized controller 1 Cover Remove the cover with a flathead screwdriver. 1 B Screw 2 Base plate 1 3 Switch box 1 4 Room name stickers 1 5 Rubber seal (large) 2 6 Rubber seal (small) 1 7 Sealing material (adhesive) 4 8 Mounting screw M4 30 2 1 2 3 4 5 6 7 8 Items to Prepare at the Installation Site M & Contact terminal interface (MC-397IF-E) One per air conditioner B Power supply wire (2-core + ground) 1.5 mm2, in conformity with Design 245 IEC 57. 1 C Connection wire Wire specification CVV (3-core) 0.5 mm 2 or equivalent * CVV is a control cable which is sheathed in polyvinyl chloride with polyvinyl insulated wires inside. One per air conditioner B C D Ring tongue terminal for M4 1 E PG connection 1 D E Mounting Wall This centralized controller can be mounted on a wall with a thickness of 6 30 mm. Since the maximum wall thickness for the centralized controller s mounting screw M4 30 8 is 17 mm, use screws of the appropriate length for the wall thickness if the wall is between 17 mm and 30 mm thick. (The best length for an M4 mounting screw is the wall thickness plus 13 mm.) 3

2-1. Connection Requirements The M & Contact terminal interface (MC-397IF-E) is necessary to connect MC-821SC-E with RC. Power supply ~/N 220 240 V 50/60 Hz Ground Power supply wire B Breaker * L N D C M MC-821SC-E TB571 TC1 TC2 TM1 TM2 CN560 MC-397IF-E 5 CN105 ir conditioner Indoor unit Breaker capacity 10 Connect to the supply terminals and leave a contact separation of at least 3 mm at each pole to disconnect the source power pole. (When the power switch is shut off, it must disconnect all poles.) 2-2. Selecting an Installation Site The centralized controller 1 is an exposed, wall-mounted model. Install the unit in a dry location. For information on selecting a mounting wall, see the Mounting Wall in section 2. Switch Box The centralized controller power and connection wiring is generally direct wired. The switch box 3 supplied (with switch box covers for 2 units) should therefore be used for installing the centralized controller. 2-3. Electrical Work Use 1.5 mm 2 power supply wire (2-core + ground). For the connection wire C, use a control cable CVV (0.5 mm 2 3-core) or equivalent product. CVV is a control cable which is sheathed in polyvinyl chloride with polyvinyl insulated wires inside. Complete the power supply wire and connection wire work before mounting the centralized controller. The electrical work should be performed in accordance with the Technical Standards Regarding Electrical Equipment and the Interior Wiring Standards. 2-4. ssigning ir Conditioner Device Numbers The numbers (1 8) displayed on the control panel of the centralized controller 1 correspond to the numbers of each connected air conditioner (device number). ssign air conditioner device numbers that correspond to the numbers shown on the control panel based on the structure of the building or the layout of the rooms in which the air conditioners are installed. 4

2-5. Sample of Configuration This figure shows a sample 4-unit configuration. (max. length of 100 m) /C Device No. 2 /C Device No. 3 Power supply ~/N 220 240 V 50/60 Hz /C Device No. 1 Centralized controller 1 /C Device No.4 M & Contact terminal interface (MC-397IF-E) 2-6. Mounting Diagram Base plate 2 (3-core) Rubber seal (large) 5 (3-core) Power supply wire B Centralized controller 1 Cover Wall PG connection E Screw Mounting screw 8 M4 30 Sealing material 7 (adhesive) Mounting screw (M4 10) 5

3. Mounting the Centralized Controller/Direct Wiring 3-1. Mounting Preparations 1 Remove 2 screws, and remove the base plate 2 from the switch box 3. Set the 2 screws aside, as they will be used in the section on 4-1. Mounting the Base Plate under Mounting the Centralized Controller. 2 Insert the switch box 3 into the wall. Size the hole in the wall to ensure that there is go gap between the switch box 3 and the wall surface. Use the switch box 3 wall installation dimensions and opening dimensions shown in the figure below. 3 Feed the power supply wire B, connection wire C, and ground wire from inside of the wall, and pull them through the switch box 3 into the room about 150 mm. Screw M4 Base plate 2 In addition, when not using a conduit for a connection wire C, be sure to install a rubber seal (large) 5 or rubber seal (small) 6 into the hole in the switch box 3 before feeding the connection wire C through the hole. Use the PG connection E prepared at the installation site to secure the power supply wire B in the hole in the switch box 3. Wall Wall opening dimensions 100 ± 3 mm * Do not make the hole any larger than necessary. Rubber seal (large) 5 0 5 mm Connection wire C Wall opening dimensions 108 ± 3 mm 150 mm 57 mm or more Power supply wire B PG connection E 4 fter the screws have been removed from the cover of the centralized controller 1, remove the cover using a flathead screwdriver. 6

3-2. Connecting the Connection Wire 1 Connect the power supply wire (2-core + ground) B to the power terminal. fter they are connected, check that the wires cannot be easily pulled off. Washer (3-core) Power terminal Power supply wire B (2-core + ground) Signal terminal Work on Power Supply wire End Be sure to use 1.5 mm 2 power supply wire B (2-core + ground). The work on power supply wire end should be performed as shown in the figure below. Ring tongue 80 mm terminal for M4 D (3-core) 10 mm 8 mm Ground 2 Mount the ground wire using the ground wire mounting screws. 3 Connect the connection wire (3-core) C to the M & Contact terminal interface (MC-397IF-E), (sold separately) corresponding to the air conditioner device number of each unit on the signal terminal. One signal terminal can be used for connecting 4 rooms. Signal terminal Work on Connection Wire End Note: Centralized controller side 6 mm 100 mm * Connect the devices corresponding to their display number on the control panel. Connect the centralized controller to the adapters as shown below. Centralized controller D C M Connection wire (3-core) TC1 TC2 TM1 TM2 M & Contact terminal interface 7

4. Mounting the Centralized Controller 4-1. Mounting the Base Plate Insert the base plate 2 into the switch box 3, and remount it using the screws removed in the 3-1 Mounting Preparations. Be sure to mount the base plate 2 so the up arrow is facing upward. lso, be careful not to damage the wires by getting them caught between plate and the switch box 3. Screw M4 Up arrow Base plate 2 Screw 4-2. Mounting the Centralized controller 1 Before mounting the unit, apply the supplied sealing materials 7 to the base plate 2, and fill in the space between the switch box 3 and the hole in the wall (a gap here could result in dew condensation). Cut the sealing material 7 to a length such that it can be wrapped around the hole in the wall based on the fixed position. 2 Connect the connection cord from the base plate 2 through the slot in the centralized controller. Centralized controller 1 Base plate 2 Wall Mounting screw 8 M4 30 Sealing material 7 3 Mount the centralized controller to the base plate 2 using the supplied mounting screw 8. Be careful not to damage the connection wires by getting them caught in the walling materials. 4 Using the supplied screw, attach the cover to the centralized controller. 5 To attach the cover to the centralized controller, fit the tabs along the top of the cover into the holes in the centralized controller and then push the lower portion of the cover into place. Caution Be sure not to tighten the mounting screw 8 too tight. Doing so may disfigure the centralized controller and prevent the cover from closing securely. Base plate 2 * Pass through the slotted hole Mounting screw 8 M4 30 Cover Screw Centralized controller * Pass through the slotted hole Sealing material 7 Extra connection wire can be stored in the area between the centralized controller and the cover. 8

5. Test Run test run should be performed after the centralized controller and the M & Contact terminal interface (MC-397IF-E) have all been installed. 1 Turn the power switch on each air conditioner to ON. 2 Press the ON/OFF button on the wireless remote controller for each air conditioner to make sure the air conditioner turns on, and then press the button again to turn each unit off. 3 Supply power (C 220 240 V) to the centralized controller. 4 Press the ON/OFF button on the upper part of the control panel of the centralized controller, and confirm that the (green) operation indicator lamp for that device number comes on. lso confirm that the corresponding air conditioner has turned on (the operation indicator lamp will not come on if the air conditioner is not connected). 5 Press the ON/OFF button again, and confirm that the operation indicator lamp goes out and that the air conditioner unit turns off. 6 Repeat steps 4 and 5 again for each device number. 7 Press the ll OFF button, and confirm that all the (green) operation indicator lamps go out and that all the air conditioners turn off. 6. Room Name Display Select the appropriate stickers from the room name stickers 4 supplied, and affix them to the display section of the panel. Room name stickers 4 7. Specifications Model MC-821SC-E No. of controlled air conditioners 8 units Power ~/N, 220 240 V, 50/60 Hz Power consumption 4 W Current 0.02 mbient temperature 0 40 C Dimensions (H W D) 120 120 15 Weight 910 g 9

This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is based on the following EU regulations: Low Voltage Directive 73/23/EEC Electromagnetic Compatibility Directive 89/ 336/EEC HED OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MRUNOUCHI, CHIYOD-KU, TOKYO 100-8310, JPN SG79Y547H02 Printed in Japan