INSTALLATION INFORMATION FOR TRANE UNITS

Similar documents
T841A Heating-Cooling Heat Pump Thermostat

Emergency Heat slide switch on the panel or an external switch. Do not use the panel switch or the external switch if Dip switch #4 is set to HP.

T8000, T8001 Programmable Thermostat

How To Set Up A Furnace Pump

Programmable Thermostats Installation, Start-Up, and Operating Instructions

INSTALLATION REMOVE OLD THERMOSTAT ATTACH THERMOSTAT BASE TO WALL CHECK THERMOSTAT OPERATION BATTERY LOCATION

General Information. Do programmable thermostats really save energy?

TCONT802AS32DA Touch Screen and TCONT803AS32DA Touch Screen with Dehumidification Control Comfort Controls

Visit Installation and Start-Up Instructions

LOW VOLTAGE CONTROL CIRCUIT WIRING

HEAT PUMP PROGRAMMABLE THERMOSTAT

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

INSTALLATION AND OPERATION MANUAL

Visit Installation and Start-Up Instructions

RESIDENTIAL THERMOSTATS CLIMATEMASTER

SMART TEMP UNIVERSAL 5/2-DAY PROGRAMMABLE THERMOSTAT (FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS) INSTALLATION AND OPERATING INSTRUCTIONS

How To Make A High Efficiency Thermostat

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

TRIUMPH TR2 - TR4A WIRING DIAGRAMS

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Zoning Reference Guide

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

DMH110b Lighted Non-Programmable Thermostat

HS2/Bx. Operating Instructions

1F78 CAUTION CONTENTS YOUR THERMOSTAT REPLACES PREPARATIONS. Installation Instructions for. Heating & Air Conditioning. Non-Programmable Thermostat

Boiler Applications Drawings

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

South East of Process Main Building / 1F. North East of Process Main Building / 1F. At 14:05 April 16, Sample not collected

OMX-RS232 Control Interface

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

EcoDesign & Labelling Directive (ErP)

Nest Learning Thermostat Pro installation & configuration guide

TECHNICAL BULLETIN. Wiring Diagrams. TPI Wiring. TB Rev. March 4, 2013 Page 1 of 5. Switch Settings 3 PHASE POWER SUPPLY 3 PHASE POWER SUPPLY

Thermostat Wire Adapter

Heating and Cooling Basics Thermostat Control

Install Guide 3M-50. Caution. Caution

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

FOCUS Service Management Software Version 8.5 for CounterPoint Installation Instructions

This slide is hidden. It will not show up during presentation.

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

WIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873

Install Guide CT101. Caution. Caution

Wireless Light-Level Monitoring

Operator: Save these instructions for future use!

AIR HANDLER INSTALLATION INSTRUCTIONS

INSTALLER S SYSTEM SETUP GUIDE

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

Electric Flow Boiler

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

FOCUS Service Management Software Version 8.5 for Passport Business Solutions Installation Instructions

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Use Cases and Scenarios

Owner s Manual Phoenix Solution. LGR Performance Amplifier

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Communicating Wall Control Installation Manual TSTAT0101SC

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Welcome to CNIPS Training: CACFP Claim Entry

Dyeing Programmer DP - 01

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

Features and Benefits

WARNING. Damper Control Module for. Comfort Sync Zoning System CONTROLS KITS AND ACCESSORIES

Table of Contents. 1 - Specifications Installation Wiring User controls...7

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

"($!$* =3 5.# 19 = 77##.# A "#$%!&#$'$()(!* "!$& %$!$*%!&& +", !"#$$"!"" %&!'""$&(&! )*""! %$"'""+,($" -. *""!

1F Programmable Electronic Digital Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Optimal Payments Extension. Supporting Documentation for the Extension Package v1.1

Chorus UFB Services Agreement Bitstream Services: Service Description for UFB Handover Connection

SMM. Installation Operation Maintenance

City of Dallas 1.5 MGD WWTP

Proliphix. Remote Management. User Guide

Installation Questions

Troubleshooting with ABS Service Data Kit


Adobe Sign. Enabling Single Sign-On with SAML Reference Guide

:: ADMIN HELP AT A GLANCE Contents

Server Settings

Split System Heat Pump Product Data

Fundamentals of Electrochemistry CHEM*7234 CHEM 720 Assignment #1 ANSWERS. [ Ag + Ê Á =

4.8. Set Operations. There are five main set theoretic operations, one corresponding to each of the logical connectives. Name

Air Top 3500/ Circuit Diagrams

Liebert Deluxe System/3

Master & Amplifier For ModuSat Communal Heating

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Split Controller. User Manual SM-SS-F 2009/01/04

V-MAC III Fault Assignments

ROTEX Gas-Hybrid-Heat Pump

User s Guide. Moduc Elements MagiCAD plugin

Transcription:

INSTALLATIN INFMATIN F TANE UNITS 1. TANE ENEIZES THE SWITCHVE VALVE IN CLIN 2. N TW STAE AS HEAT U CAN JUMPE FIST & SECND STAE TETHE, FIST STAE STATS AFTE 10 MINUTES SECND STAE TAKES VE UNTIL THE THEMSTAT SATISFIES. 3. U SHULD ET IN THE HAIT F ININ ALL LW VLTAE WIIN ACK T THE AI HANLE FUNACE LW VLTAE TEMINAL AD. 4. VAIALE SPEED IND LWES ALLW U T SET THE CFM : 350 CFM TN, 400 CFM TN, 450 CFM TN. 400 CFM TN IVES EST PEFMANCE. 5. VAIALE SPEED IND LWES, MAKE SUE U SET DIP SWITCHES : 1-4 IS F CLIN CFM, 5 & 6 IS F DELA (SET 5 & 6 N F ENHANCED MDE), 7 & 8 IS F AUXILIA HEAT/AS HEAT CFM. 6. N TW STAE CLIN & HEATPUMP UNITS U NEED T USE A TANESUPPLIED THEMSTAT F EST ESULTS. 7. WHEN INSTALLIN 8, 600, 400 AND 200 SEIES TANE T-STATS U MUST ENTE THE INSTALLES SET-UP T PAM THEM ACCDIN T THE EQUIPMENT USED AND THE IMPTANT PEATIN INSTUCTINS. 8. USE THE SEVICE FACTS T ET A LT F INFMATIN THAT U MA NEED: CHAIN INF, ELECTICAL INF, DIP SWITCH SETTINS F VAIALE SPEED IND LWES. 9. N TANE EQUIPMENT THE LUE LW VLTAE WIE IS ALWAS 24V CMMN. 10. ALWAS DISALE CLIN DP N AN T-STAT THAT IVES U THE PTIN T D S.

SPLIT HEAT PUMP ASIC WIIN UTD AI HANDLE STAT SWITCHVE W CNTACT 24 VLTS CMMN EMEENC HT AUXILIA HT

AI CNDITINE SPLIT WITH 2 STAE HEAT UTD FUNACE STAT AFTE 10 MIN 2ND STAE WILL PEATE FIELD INSTALLED JUMPE 1 STAE HEAT CNTACT 24 VLTS CMMN

SPLIT HEAT PUMP WITH HEAT STIP WITH TANE STAT HEAT PUMP AI HANDLE STAT SWITCHVE W CNTACT 24 VLTS CMMN EMEENC HT AUXILIA HT

PACKAED AS / ELECTIC FIELD WIIN UNIT STAT 1 STAE HEAT CNTACT 24 VLTS CMMN

UNIT PACKAED AS / ELECTIC FIELD WIIN WITH 2 STAE HEAT TANE STAT STAT 1 STAE HEAT 2 STAE HEAT CNTACT 24 VLTS CMMN

UNIT PACKAED AS / ELECTIC FIELD WIIN WITH 1 STAE HEAT TANE STAT AFTE 10 MIN 2ND STAE WILL PEATE FIELD SUPPLIED JUMPE IF DESIED STAT 1 STAE HEAT CNTACT 24 VLTS CMMN

UNIT PACKAED HEAT PUMP FIELD WIIN WITH N STIP HEAT STAT W F AUXILIA HT EMEENC HEAT FAULT SWITCHVE CNTACT 24 VLTS CMMN

PACKAED HEAT PUMP WITH STIP HEAT UNIT STAT FIELD SUPPLIED JUMPE W AUXILIA HT EMEENC HEAT F FAULT SWITCHVE CNTACT 24 VLTS CMMN

XL16C PACKAED HEAT PUMP FIELD WIIN UNIT WITH N STIP HEAT STAT 1 2 ellow/ed W 2 F AUXILIA HT EMEENC HEAT SWITCHVE 1 ST STAE 2 ND STAE 24 VLTS CMMN FAULT

XL16C PACKAED HEAT PUMP WITH STIP HEAT UNIT STAT FIELD SUPPLIED JUMPE W AUXILIA HT EMEENC HEAT SWITCHVE 1 1 ST STAE 2 ellow/ed 2 2 ND STAE 24 VLTS CMMN F FAULT

XL16C PACKAED AS / ELECTIC FIELD WIIN UNIT WITH 2 STAE HEAT TANE STAT STAT 1 STAE HEAT 2 STAE HEAT 1 2 ELLW/ED 2 1 ST STAE 2 ND STAE 24 VLTS CMMN

XL16i SPLIT HEAT PUMP (24 volt application) 2 STEP CMPESS V.S. AI HANDLE STAT SWITCHVE 1 1 ST STAE 2 ELLW/ED FIELD SUPPLIED JUMPE K 2 2 ND STAE 24 VLTS CMMN NTE; THE T K JUMPE N THE AI HANDLE LW VLTACE TEMINAL MUST E EMVED.

XL16i SPLIT AI CNDITINE/FUNACE (24 volt application) WITH TANE STAT UTD 2 STAE V.S. FUNACE STAT 1 STAE HEAT 2 STAE HEAT 1 1 ST STAE 2 ELLW/ED FIELD SUPPLIED JUMPE K 2 2 ND STAE 24 VLTS 24 VLTS CMMN NTE: WHEN INSTALLIN A 16i C/U WITH A AS FUNACE THE 4 JUMPE MUST E CUT N THE FUNACE CNTL AD.

XL20i SPLIT HEAT PUMP WITH HEAT STIP (24 volt application) WITH TANE STAT HEAT PUMP AI HANDLE STAT SWITCHVE 1 L 1 ST STAE 2 ELLW/ED 2 2 ND STAE 24 VLTS CMMN EMEENC HT FIELD INSTALLED JUMPE IF DESIED W AUXILIA HT

XL20i SPLIT AI CNDITINE/FUNACE (24 volt application) WITH 1 STAE HEAT TANE STAT UTD FUNACE STAT 1 2 ELLW/ED Field supplied Jumper can be to ; or lo to L 2 1 STAE HEAT 2 STAE HEAT 1 ST STAE 2 ND STAE 24 VLTS CMMN

Communicating Systems All Communicating systems will wire the same is 24 volts Hot is Common D is for Data The wiring diagram on the following page applies to the 16i, 19i & 20i communicating systems. All systems will have the same wiring, regardless of it s a furnace, Heat Pump or Dual Fuel application.