TCONT802AS32DA Touch Screen and TCONT803AS32DA Touch Screen with Dehumidification Control Comfort Controls
|
|
|
- Simon Copeland
- 9 years ago
- Views:
Transcription
1 CN80AS3DA ouch Screen and CN803AS3DA ouch Screen with Dehumidification Control Comfort Controls 8-HD5D9-3 APPLICAIN INSALLAIN INSUCINS he CN80AS3DA and CN803AS3DA ouch Screen Comfort Controls provide electronic control of 4 Vac heating and cooling systems. See able for a general description. able. CN80AS3DA and CN803AS3DA Comfort Control Description. Power Method Changeover System Selection an Selection Comments 4 Vac common wire Automatic or manual selectable Heat-ff-Cool- Auto (Em. Heat for heat pumps) n-auto-circ System and an selection vary based on system type System and an selection vary based on System type. Humidity sensor to control dehumidification. MECU NICE If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Dispose of properly. Selecting Location Install the comfort control about 5 ft. (.5m) above the floor in an area with good air circulation at average temperature. See ig.. Contact your local waste management authority for instructions regarding recycling and the proper disposal of the old control. INSALLAIN ES N When Installing this Product.... ead these instructions carefully. ailure to follow the instructions can damage the product or cause a hazardous condition.. Installer must be a trained, experienced service technician. 3. After completing installation, use these instructions to check out the product operation. N N 5 EE [.5 MEES] M995 ig.. Selecting comfort control location. U.S. Pat. No , D5095, and ther Patents Pending
2 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN Do not install the comfort control where it can be affected by: Drafts or dead spots behind doors and in corners. Hot or cold air from ducts. adiant heat from sun or appliances. Concealed pipes and chimneys. Unheated (uncooled) areas such as an outside wall behind the comfort control. 3. Securely tighten each screw. 4. Push excess wire back into the hole. 5. Plug the hole with nonflammable insulation to prevent drafts from affecting the comfort control. HEA PUMP HEA/CL Installing Wallplate C C CAUIN Electrical Hazard. Can cause electrical shock or equipment damage. Disconnect power before wiring. X W S S W W S S SCEW EMINALS M636 he comfort control can be mounted horizontally on the wall or on a 4 in. x in. (0.6 mm x 50.8 mm) wiring box.. Position and level the wallplate (for appearance only).. Use a pencil to mark the mounting holes. WALL WIES HUH WALL AND WIE SL WALL ANCHS () ig. 3. Selecting terminal identifications for system type. able. Selecting erminal Identifications for System ype. System ype Wallplate erminal Identifications Wiring Diagram eference Standard Heat/Cool Heat/Cool ig. 5, ig. 6 Standard Multistage up to Heat/ Cool Heat/Cool ig. 7, ig. 8 MUNIN HLES Heat Pump with Electric Auxiliary (ackup) Heat Heat Pump ig. 9, ig. 0, ig. MUNIN SCEWS () M996 Heat Pump with ossil uel Auxiliary (Dual uel) Heat Heat Pump ig., ig. 3, ig. 4, ig. 5 ig.. Mounting wallplate. 3. emove the wallplate from the wall and, if drywall, drill two 3/6-in. holes in the wall, as marked. or firmer material such as plaster, drill two 7/3-in. holes. ently tap anchors (provided) into the drilled holes until flush with the wall. 4. Position the wallplate over the holes, pulling wires through the wiring opening. See ig.. 5. Insert mounting screws into the holes and tighten. WIIN (I. 5-5) NE: he factory default setting is configured for a Heat/ Cool System with a gas furnace. All wiring must comply with local electrical codes and ordinances.. Select set of terminal identifications (able ) that corresponds with system type (heat/cool or heat pump in ig. 3).. Loosen the screws for the appropriate system type selected; see able. Insert wires in the terminal block under the loosened screw. See ig. 4. M997 ig. 4. Inserting wires in terminal block. IMPAN Use 8 gauge comfort control wire. Pub. No. 8-HD5D
3 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN HEA/CL HEA/CL W S S C W W S S C W W W W3 /C AI HANDLE K L W W /C VAIALE SPEED W-SAE UNACE/VAIALE SPEED AI HANDLE IND UD IND UD D CLIN UNI.D. SECIN (SINLE SAE) CLIN UNI.D. SECIN (W SAE) PWE SUPPL PE LCAL CDES NL) PWE SUPPL PE LCAL CDES NL) AC INSALLED JUMPE. AC INSALLED JUMPE. PINAL UD IND EME SENS. AVAILALE N SELEC MDELS. WIES MUS HAVE A CALE SEPAAE M HE HEMSA CALE. M637 PINAL UD IND EME SENS. AVAILALE N SELEC MDELS. WIES MUS HAVE A CALE SEPAAE M HE HEMSA CALE. M640 ig. 5. ypical hookup of single-stage heat and cool system with single transformer (H/C). ig. 7. ypical hookup of two-stage indoor and two-stage cooling unit in a single transformer system (H/C or H/C or H/C). HEA/CL HEA/CL W S S C W W S S C W 3 W IL UNE PIMA /C IL UNACE K L W W /C VAIALE SPEED W SAE UNACE IND UD IND UD CLIN UNI.D. SECIN (SINLE SAE) 6 SEE CLIN UNI.D. SECIN (W SEP) PWE SUPPL PE LCAL CDES NL) PWE SUPPL PE LCAL CDES NL) PINAL UD IND EME SENS. AVAILALE N SELEC MDELS. WIES MUS HAVE A CALE SEPAAE M HE HEMSA CALE. M638 AC INSALLED JUMPE. PINAL UD IND EME SENS. AVAILALE N SELEC MDELS. WIES MUS HAVE A CALE SEPAAE M HE HEMSA CALE. ig. 6. ypical hookup of single-stage heat and cool system with two transformers (H/C). 3 HE INSALLE MUS JUMPE A HE LV. M43 ig. 8. ypical hookup of two-stage indoor and two-step scroll cooling unit in a single transformer system (H/C or H/C or H/C). Pub. No. 8-HD5D
4 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN HEA PUMP X W S S C I-P PM-A W D- D- IND UD W W3 SUPPL. H. CNL X EQ. PWE 3 PH SUPPL PE LCAL CDES AND AS DEINED IN IELD WIIN ALE /C AI HANDLE X/K () HEA PUMP.D. SECIN (SINLE SAE) PWE SUPPL PE LCAL CDES NL) AC INSALLED JUMPE. PINAL UD IND EME SENS. AVAILALE N SELEC MDELS. WIES MUS HAVE A CALE SEPAAE M HE HEMSA CALE. M64 ig. 9. ypical hookup of single-stage heat pump with auxiliary/backup heat (H/C heat pump). HEA PUMP X W S S C I-P PM-A K L W D- D- IND UD W W3 SUPPL. H. CNL X EQ. PWE 3 PH SUPPL PE LCAL CDES AND AS DEINED IN IELD WIIN ALE /C VAIALE SPEED AI HANDLE X/K () HEA PUMP.D. SECIN (W SAE) PWE SUPPL PE LCAL CDES NL) AC INSALLED JUMPE. PINAL UD IND EME SENS. AVAILALE N SELEC MDELS. WIES MUS HAVE A CALE SEPAAE M HE HEMSA CALE. M64 ig. 0. ypical hookup of multistage heat pump with auxiliary/backup heat (3H/C heat pump). Pub. No. 8-HD5D
5 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN HEA PUMP X W S S C 3 K L W W /C VAIALE SPEED AI HANDLE IND UD X/K () PWE SUPPL PE LCAL CDES NL) 6 SEE HEA PUMP.D. SECIN (W SEP) 3 AC INSALLED JUMPE. UD EME SENS. WIES MUS HAVE A CALE SEPAAE M HE HEMSA CALE. HE INSALLE MUS JUMPE A HE LV. M430 ig.. ypical hookup of multistage two-step scroll heat pump with auxiliary/backup heat (3H/C heat pump). HEA PUMP X W C S S W W /C NN-V.S. NE W SAE AS UNACE IND UD X/K () HEA PUMP.D. SECIN (SINLE SAE) PWE SUPPL AC INSALLED JUMPE. PE LCAL CDES UD EME SENS. WIES MUS HAVE A CALE SEPAAE M HE HEMSA CALE. NL) M400 ig.. ypical hookup of singe-stage heat pump with non-variable speed gas furnace. Pub. No. 8-HD5D
6 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN HEA PUMP X W C S S K L W W /C VAIALE SPEED W SAE UNACE IND UD /X () K HEA PUMP.D. SECIN (SINLE SAE) PWE SUPPL AC INSALLED JUMPE. PE LCAL CDES UD EME SENS. WIES MUS HAVE A CALE SEPAAE M HE HEMSA CALE. NL) M40 ig. 3. ypical hookup of single-stage heat pump with two stage variable speed gas furnace (H/C heat pump). Pub. No. 8-HD5D
7 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN HEA PUMP X W C S S K / / W W /C L VAIALE SPEED W SAE UNACE IND UD X/K () HEA PUMP.D. SECIN (W SAE) PWE SUPPL AC INSALLED JUMPE. PE LCAL CDES UD EME SENS. WIES MUS HAVE A CALE SEPAAE M HE HEMSA CALE. NL) M40 ig. 4. ypical hookup of multistage heat pump with two stage variable speed gas furnace (3H/C heat pump). Pub. No. 8-HD5D
8 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN HEA PUMP X W C S S K L W W /C 3 VAIALE SPEED W SAE UNACE IND UD X/K () 6 SEE HEA PUMP.D. SECIN (W SEP) 3 PWE SUPPL AC INSALLED JUMPE. PE LCAL CDES UD EME SENS. WIES MUS HAVE A CALE SEPAAE M HE HEMSA CALE. EMVE / CU JUMPE M K. NL) M403 ig. 5. ypical hookup of multistage two-step scroll heat pump with two stage variable speed gas furnace (3H/C heat pump). Powering the Comfort Control he Comfort Control can be powered with 4 Vac. 4 Vac Common Power (ecommended) Wire the common side of the transformer to the screw of the comfort control wallplate. When installing in a single transformer system, keep the jumper wire between the and c screws. When installing in a two-transformer system, use the common from the cooling transformer to connect to the screw and remove the jumper wire between the and c screws. hree AAA alkaline batteries can be used to power the comfort control for armchair programming only. o prevent the comfort control and heating/cooling system from shutting down due to lack of battery power, it is not recommended that the comfort control be solely powered with the three AAA batteries during normal system operation. When using batteries, make sure positive and negative terminals are oriented correctly, as marked on the device. See ig. 6. attery Power (ptional) CAUIN Equipment or Property Damage Hazard. Using battery power only may not provide adequate power to comfort control and can cause damage during freezing conditions. Connect the 4 Vac Common () wire from the system transformer to the comfort control for proper operation when the battery power is drained. AEIES (3) M998 ig. 6. Installing batteries on comfort control back. Pub. No. 8-HD5D
9 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN Mounting the Comfort Control. Align the terminal screw blocks with the pins on the back of the comfort control.. Push the comfort control straight onto the wallplate. See ig. 7. his comfort control is designed to automatically keep the current time and day in memory for up to ten years under normal use once the calendar is set. When the comfort control is first powered, the display is ready for the calendar date to be entered. See ig. 9. WALL SE CUEN DA SE MNH WED MN UE HU I SA SUN DNE EMVE DUIN INSALLAIN USE AWS SE EA AND IME M643 ig. 7. Mounting comfort control on wallplate. Adjusting eal-ime Clock MN WED HU I SA K PICK MULIPLE DAS SCEEN LCKED CHANE ILE UV LAMP HUMIDIIE PAD SUN Setting Calendar and ime Locate and remove the tab labeled emove in the lower left corner on the comfort control back. he tab must be removed to activate the real-time clock. See ig. 8. EMVE A ACIVAE EAL IME CLCK DNE M645 ig. 9. Setting calendar and time after initial powerup. EMVE DUIN INSALLAIN EMVE DUIN INSALLAIN IMPAN he tab on the back of the comfort control in the lower left corner must be removed for this feature to be active. Using the Comfort Control he comfort control has a touch screen interface. Words or symbols appear, highlighting the keys, as necessary, to complete tasks. Always press the keys with your fingertips. Sharp instruments like a pen or pencil point can damage the comfort control. M644 ig. 8. emoving tab to activate real-time clock.. Use the arrow keys to set the ear, Month and Day, as shown in ig. 9.. Press the Done key. 3. Use the arrow keys to set the current time. See ig Press the Done key. Pub. No. 8-HD5D
10 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN PEAIN System and an Settings he System default setting is Heat and the an default setting is Auto. SSEM SEINS Heat: controls heating system. ff: heating and cooling are off. Cool: controls cooling system. Auto: automatically changes between heating and cooling systems, depending on indoor temperature. (See Installer Setup section.) Em Heat: emergency heat cycles to maintain temperature. Compressor is locked out. (Used only for heat pump systems with backup heat.) AN SEINS he an setting can be programmed into the comfort control schedule for each period (Wake, Leave, eturn, Sleep). See the wners uide for additional information. LED Indication (equires 4 Vac Common Connection) An LED indicator is located in the upper right corner of the comfort control. It is only visible when lighted: It indicates when the comfort control is in the Emergency Heat mode. When in Em. Ht. mode, the terminal is continuously energized and the LED is on. When the terminal is wired to an equipment monitor, the LED signals when a check or fail signal is sent to the comfort control from the system. See ig. 0. (his can occur only when the comfort control is not in Em. Ht. mode.) C ig. 0. terminal switch to (power) side of system transformer. Preprogrammed Settings able 3 shows the default program settings. See wners uide for complete instructions on changing the program. able 3. Default Program Settings. Schedule Period ime Heat Wake 6:00AM 70 ( C) Leave 8:00AM 6 (6.5 C) eturn 6:00PM 70 ( C) Sleep 0:00PM 6 (6.5 C) EQUIPMEN MNI Setpoints Cool 78 (5.5 C) 85 (9.5 C) 78 (5.5 C) 8 (8 C) C M646 an Setting Auto Auto Auto Auto Pub. No. 8-HD5D
11 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN INSALLE SEUP he comfort control works with many different system types. o operate correctly, the comfort control must be set up to operate the installed heating and/or cooling system. 4. elease the two blank keys when the screen on the comfort control matches the screen below. ollow these steps to enter the Installer Setup:. e sure the comfort control is powered.. Press and release the System Key. HU AN N Inside AU Set o DNE SSEM EM HEA ollowing Schedule CL A M M649 SCHED HLD CLCK SCEE M Press and hold the two blank keys on either side of the center blank key for approximately five seconds until screen changes. 5. See screen below to review how the comfort control keys are used during Installer Setup. See able 4 for the Installer Setup Numbers and Settings. INSALLE SEUP NUME ADVANCE NEX INSALLE SEUP CUEN SEIN M U WE H SA SU Inside Set o SSE M EM HEA ollowing Schedule MN WED HU I SA SUN DNE CANC DNE M648 PESS EXI INSALLE SEUP CHANE HE CUEN SEIN M Press the Done key to exit the Installer Setup screen. Pub. No. 8-HD5D
12 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN IMPAN he Installer Setup Menu (able 4) shows all the available options. hese options customize themselves as you make selections to the Installer Setup. herefore, not all Installer Setup Selections are shown or are available to change. able 4. Installer Setup Menu. actory Setting ther Choices Select Not used. Date (ear Upper) Date (ear Lower) Installer Setup Number ption Description ptions Description Comments thru Set first two digits of first two digits of current available current calendar year calendar year (xx) (0 for year 005, etc) epresents last two digits of current calendar year (005). Date (Month) Digit(s) represents current calendar month. Date (Day) Schedule ptions System ype Selection Select last two digits of current calendar year. - Select number that represents current calendar month available Digit(s) represents -3 Select number that represents current calendar date. current calendar date day programming 0 0 nonprogrammable 070 Heat/Cool - heat/cool Available options and single-stage heat pump (no defaults vary by aux. heat) 3 heat only (no fan) 4 heat only (with fan) comfort control. System selection automatically 5 hot water Series 0 (3-wire modifies some or normally open zone valves) 6 cool only 7 heat/cool heat pump 8 heat/ cool default settings and/ or hides other Installer Setup options. 9 heat/cool 0 heat/ cool oil furnace or 0H/C heat/ cool heat pump (with no auxiliary heat) 3 heat/ cool heat pump (with auxiliary heat) an peration Heat/Cool applications where equipment controls fan operation in heat mode. ackup Heat Source (Auxiliary Heat) Heat pump or electric heat applications where comfort control controls fan operation in heat mode Heat pump backup Heat pump backup heat heat source is electric. source is fossil fuel. External ossil uel Kit 00 External fossil fuel kit is controlling heat pump backup heat (recommended) Cycles per hour (cph) for st Stage Compressor 00 3 Compressor Stage cycles per hour (cph) Cycles per Compressor Stage hour (cph) for cycles per hour (cph) nd Stage Compressor 0 No external fossil fuel kit is controlling heat pump backup heat. his comfort control controls the backup fossil fuel heat with outdoor sensor available; 3 is recommended available; 3 is recommended. nly shown if heat/ cool system is selected. If heat pump is chosen, fan defaults to electric. nly shown if heat/ cool or 3 heat/ cool heat pump is chosen. nly shown if fossil fuel is chosen as backup heat source. nly shown if two stages of cool are selected. Pub. No. 8-HD5D
13 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN able 4. Installer Setup Menu. (Continued) actory Setting ther Choices Installer Setup Select Number Cycles per hour (cph) for st Stage Heat Heat Stage cycles per hour (cph) Cycles per hour (cph) for nd Stage Heat Cycles per hour (cph) for 3rd Stage Heat Cycles per hour (cph) for nd Stage Heat or Auxiliary Heat for H/C Heat Pump Systems Cycles per hour (cph) for Auxiliary Heat in 3H/C Heat Pump Systems Comments - - available; typical settings: Not shown if system cph used for steam or selection is heat gravity system. pump. Selection in 3 3 cph used for -stage this stage changes fossil fuel forced air systems or default cph for nd hot water systems. stage heat. 5 5 cph used for single-stage fossil fuel forced air systems. 9 9 cph used for electric forced air heat systems (electric auxiliary heat for heat pump systems). - - available; typical settings: nly shown if two cph used for steam or stages of heat are gravity system. selected. 3 3 cph used for -stage fossil fuel forced air systems or hot water systems. 5 5 cph used for single-stage fossil fuel forced air systems. 9 9 cph used for electric forced air heat systems (electric auxiliary heat for heat pump systems). - - available; typical settings: nly shown if 3H/C cph used for steam or heat pump system is gravity system. selected. 3 3 cph used for -stage fossil fuel forced air systems or hot water systems. 5 5 cph used for single-stage fossil fuel forced air systems. 9 9 cph used for electric forced air heat systems (electric auxiliary heat for heat pump systems). Cycles per Cycles per hour (cph) - - is available; typical nly shown if heat/ hour (cph) for for Emergency Heat settings: cool or 3 heat/ Em Heat 3 3 cph used for -stage cool heat pump is fossil fuel forced air systems or selected. hot water systems. 5 5 cph used for single-stage fossil fuel forced air systems. 9 9 cph used for electric forced air heat systems (electric auxiliary heat for heat pump systems). Continuous acklight ption Description ptions Description acklight not on continuously. Comfort control backlight comes on with each key press. acklight is on continuously (comfort control must have a common wire attached for this function). ption is always shown; however, continuously on backlight works only if comfort control is wired with 4 Vac Common. Changeover Manual changeover auto changeover Pub. No. 8-HD5D
14 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN able 4. Installer Setup Menu. (Continued) actory Setting ther Choices Select Installer Setup Number ption Description ptions Description Deadband 030 thru 9 Heating and cooling setpoints can be set no closer than chosen value: ( C) 3 3 ( C) 4 4 (.5 C) 5 5 (3 C) 6 6 (3.5 C) 7 7 (4 C) 8 8 (4.5 C) 9 9 (5 C) 3 Heating and cooling setpoints can be set no closer than 3 (.5 C). Comments Shown only if automatic changeover is selected. he deadband is restricted to the range of 5 to 9 if ISU 0380 is set to dehumidification droop control. emperature Indication Scale Daylight Savings emote emperature Sensor (utdoor or Indoor) Heat Pump Compressor Lockout emperature is displayed in Daylight savings enabled (use through 006 and for areas that do not use the new 007 DS calendar) No remote temperature sensor No compressor lockout. emperature is displayed in C. 0, 0 daylight savings is disabled. daylight savings is enabled (start using in 007, for areas that use the new 007 DS calendar). -3 outdoor temperature sensor for display only. outdoor temperature sensor for system control, used for select heat pump systems. (See Special Heat Pump eatures section for more details.) 3 indoor temperature sensor 5, 0, 5, 30, 35, 40, 45 5 (-9.5 C) 0 (-6.5 C) 5 (-4 C) 30 (- C) 35 (.5 C) 40 (4.5 C) 45 (7 C) Set to 0 in areas that do not follow daylight savings. Defaults and ptions depend on System ype selection. Indoor emperature Sensor uses an averaging network and does not include on-board sensor. Default depends on other selections. Shown if utdoor emperature for control is selected. Heat Pump Auxiliary Lockout No heat pump auxiliary lockout. Indoor No indoor Dehumidification dehumidification Control control. urnace ilter Change eminder Humidifier Pad eplacement eminder urnace filter change reminder off. 40, 45, 50, 55, (4.5 C) 45 (7 C) 50 (0 C) 55 (3 C) 60 (5.5 C dehumidification droop control run time days 30 run time days 3 60 run time days 4 90 run time days 5 0 run time days run time days Humidifier pad calendar days replacement reminder 80 calendar days off calendar days Shown if electric is chosen for backup heat source and outdoor temperature sensor for control is selected. Available on models with humidity sensor. un time based on call for fan. Pub. No. 8-HD5D
15 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN able 4. Installer Setup Menu. (Continued) actory Setting ther Choices Select Adaptive Intelligent ecovery Number of Periods Minimum Compressor ff ime Heat emperature ange Stop Cool emperature ange Stop 0530 Adaptive Intelligent ecovery control is activated (system starts early so setpoint is reached by start of program period). 0 0 conventional recovery (system starts recovery at programmed time) our periods available wo periods available (Wake (Wake, Leave, eturn, and Sleep) Sleep) ive minute minimum off time for compressor Highest heating setpoint Lowest cooling setpoint. 0,, 3, 4 Minimum number of minutes compressor is off between calls for compressor. 40 to 89 emperature range ( increments) of heating setpoint. 5 to 99 emperature range ( increments) of cooling setpoint. Comments Not shown if non-programmable is selected. or 4 applies to all days of the week. ive minutes recommended Shown in / C. Shown in / C. Clock ormat hour clock format 4 4-hour clock format Extended an on time Heat Extended an on time Cool Keypad Lockout Installer Setup Number ption Description ptions Description No extended fan 90 an operation is extended 90 operation after call for seconds after call for heat heat ends. ends No extended fan 90 an operation is extended 90 operation after call for seconds after call for cool cool ends. ends Unlocked keypad, partially locked keypad fully locked keypad Not shown if fan operation is set to fossil fuel or in Cool nly Systems Not shown in Heat nly Systems. Unlocked all functions are available. Partially locked only temperature up and down keys and ability to enter and modify Installer Setup mode are available. ully locked only ability to enter and modify Installer Setup mode are available. Pub. No. 8-HD5D
16 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN able 4. Installer Setup Menu. (Continued) actory Setting ther Choices Select emperature Control in Heat emperature Control in Cool Installer Setup Number 0680 Standard temperature control in heating. ption Description ptions Description 0690 Standard temperature control in cooling., 3 less aggressive temperature control (could cause temperature undershoot) 3 more aggressive temperature control (could cause temperature overshoot), 3 less aggressive temperature control (could cause temperature undershoot) 3 more aggressive temperature control (could cause temperature overshoot) emperature No difference in -3, -, -3 (-.5 C) Display ffset displayed temperature -, 0,, - (- C) and actual room temperature., 3 - (-0.5 C) 0 (0 C) (0.5 C) ( C) 3 (.5 C) eset Comfort No comfort control Control reset. esets all Installer Setup ptions to default values and resets schedule to default setting. Comments Applies to recovery ramp and use of auxiliary heat during recovery. Choose if getting temperature overshoot. Choose 3 if getting temperature undershoot. Applies to recovery ramp. Choose if getting temperature overshoot. Choose 3 if getting temperature undershoot. nly calendar settings and time are retained. Pub. No. 8-HD5D
17 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN SSEM CHECKU Installer System est he Installer System est mode is used to test the HVAC system(s). See able 5. While in System est mode, minimum off-time for compressors is bypassed. he Installer est is part of the Installer Setup options. Enter Installer Setup screen and press the Down arrow key to bring up test selection(s) quickly. CAUIN Equipment Damage Hazard. Minimum compressor off-time is bypassed during Installer System est. Avoid cycling compressor quickly. able 5. System est(s). Select Installer Setup Number actory Setting ther Choices ptions Description ptions Description Comments Installer est Cool Installer est an Installer est Heat est 0 Cool is off, 0 cool off cool stage turns on cool stages and on est 0 an is off 0 fan off fan turns on est 3 0 Heat is off -3 0 heat off stage heat on stages and heat on 3 stages, and 3 (Aux Ht) on System selection determines which tests are available and the number of stages shown. Installer est Em Ht est 4 0 Emergency heat is off 0 emergency heat off emergency heat on emergency heat and auxiliary heat turn on Available only if heat pump with auxiliary heat is selected. Pub. No. 8-HD5D
18 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN ADVANCED EAUES utdoor or Indoor emperature Sensor or accuracy, the initial reading of the indoor and outdoor temperature sensors require five minutes to stabilize. See the Sensor instructions for installation information. Special Heat Pump eatures Heat Pump with ossil uel Auxiliary Heat (Dual uel) and utdoor emperature Sensor In this operation there is no external fossil fuel kit (dual fuel kit) installed; the comfort control controls this function.. Choose correct heat pump application in Installer Setup Number Choose ossil uel ption as the backup heat source in Installer Setup Number Choose No External ossil uel Kit ption as controlling backup heat in installer Setup Number utdoor emperature Sensor for Control ption is automatically chosen in Installer Setup Number Choose appropriate alance Point emperature in Installer Setup Number PEAIN IN HEA MDE AVE ALANCE PIN (UD EMPEAUE) When the outdoor temperature is above the selected alance Point emperature (ISU 0350), only the compressor operates and the fan ( terminal) energizes when the comfort control calls for heat. PEAIN IN HEA MDE ELW ALANCE PIN (UD EMPEAUE) When the outdoor temperature is below the selected alance Point emperature (ISU 0350), only the ossil uel (auxiliary heat) operates and the fan ( terminal) does not energize when the comfort control calls for heat. PEAIN IN EMEENC HEA MDE he balance point (outside) temperature is not used in the Emergency heat mode. When the comfort control is moved to the Emergency Heat position, the compressor is locked out. he first stage of heat is whatever is connected to the X terminal. he second stage of heat is what is connected to the W terminal. ften there is only one source of non-compressor heat and the X terminal is jumpered to the W terminal. Heat Pump with Electric Auxiliary (ackup) Heat and utdoor emperature Sensor. Choose correct heat pump application in Installer Setup Number Choose Electric as Auxiliary (ackup) Heat Source in Installer Setup Number Choose utdoor emperature Sensor for Control ption in Installer Setup Number Choose Compressor Lockout emperature in Installer Setup Number Choose Auxiliary Lockout emperature in Installer Setup Number NE: here is a 5 deadband between the Compressor and Auxiliary Heat Lockout emperatures PEAIN IN HEA MDE When the outdoor temperature is below the Compressor Lockout emperature, only the Auxiliary Heat operates. When the outdoor temperature is above the Auxiliary Lockout emperature, only the Compressor operates. See ig.. UD EMPEAUE CMPESS NL H CMPESS AND AUXILIA HEA AUXILIA NL AUXILIA LCKU EMPEAUE CMPESS LCKU EMPEAUE ig.. Heat Pump peration with Lockout emperatures Set. M9950 When the outdoor temperature is between the two temperatures, both the Compressor and Auxiliary Heat operate. PEAIN IN HE EMEENC HEA MDE nce the comfort control is placed into the Emergency Heat mode, the compressor and auxiliary lockout features are turned off. In the Emergency heat mode, the compressor is locked out. he first stage of heat is whatever is connected to the X terminal. he second stage of heat is connected to the W terminal. Usually the emergency and auxiliary heat sources are electric strip heat in these cases. Dehumidification Droop Control he dehumidification control attempts to control to the user's humidity setpoint by turning on the air conditioner. In extremely high humidity conditions, the comfort control keeps the air conditioner running for up to 3 below the temperature setpoint. It does this while trying to achieve the desired humidity setpoint and balancing that with the temperature setpoint. Pub. No. 8-HD5D
19 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN ULESHIN (SEE ALE 6) able 6. roubleshooting. Symptom Possible Cause Action Display does not come on. emperature settings do not change. Heating or cooling does not come on. Comfort control is calling for Heat (Heat on) or Cool (Cool on) but no heating or cooling is running. Comfort control does not respond when touch areas are pressed. Comfort control is not being powered. he upper or lower temperature limits were reached. he keypad is fully locked. Comfort control minimum offtime is activated. System selection is not set to Heat or Cool. System type Selection is incorrect. Heating or cooling equipment is not operating. he keypad is locked. Check for 4 Vac between and c. Check temperature setpoints. Check Installer Setup Numbers 0600 and 060; modify as needed. Check Installer Setup Number 0670 to change keypad locked options. Wait up to five minutes for the system to respond. Set system Selection to correct position. Check Installer Setup Number 070 and make sure correct System type is chosen. Check wiring. Check Installer Setup Number 070 and make sure correct system type is chosen. Verify operation of equipment in System est mode. Check Installer Setup Number 0670 to change keypad locked options. Pub. No. 8-HD5D
20 CN80AS3DA UCH SCEEN AND CN803AS3DA UCH SCEEN WIH DEHUMIDIICAIN U.S. egistered rademark 006 American Standard Inc. All ights eserved Pub. No. 8-HD5D M.S. ev American Standard Inc. roup Highway yler, X
Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types
Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:
Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types
Installation Guide LR-HWLV-HVAC TouchPRO Wireless Touchscreen Thermostat System Types Gas, oil, or electric heat with air conditioning Warm air, hot water, high efficiency furnaces, heat pumps, steam,
COMFORT CONTROL - 4 HEAT (GAS, OIL*, OR ELECTRIC)/3 COOL/HEAT PUMP COMMUNICATING PROGRAMMABLE 3 WIRE HOOKUP
COMFORT CONTROL - 4 HEAT (GAS, OIL*, OR ELECTRIC)/3 COOL/HEAT PUMP COMMUNICATING PROGRAMMABLE 3 WIRE HOOKUP ALL phases of this installation must comply with NATIONAL, STATE, AND LOCAL CODES INSTALLER S
Installation Guide. Programmable Thermostat TH6220D
Installation Guide Programmable Thermostat TH6220D Product Application This thermostat provides electronic control of 24 VAC single-stage and multi-stage heating and cooling systems, or 750 mv heating
T841A Heating-Cooling Heat Pump Thermostat
T84A Heating-Cooling Heat Pump Thermostat APPLICATIN The T84A Heating-Cooling TADELINE Thermostat provides 4 Vac control of two-stage heating and onestage cooling in heat pump systems, using manual changeover.
Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.
Install Guide CT100 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
HEAT PUMP PROGRAMMABLE THERMOSTAT
HEAT PUMP PROGRAMMABLE THERMOSTAT SA PM 3 COOL TEMP Form 44014-01 r010408 Model 43168 Owners Manual 1 Congratulations! Heat Pump Programmable Thermostat Model 43168 THERMOSTAT CONTROLS Switches & Buttons...15
Install Guide 3M-50. Caution. Caution
PG 1 Install Guide 3M-50 aution Your thermostat is a precise instrument, handle it with care. Turn off electricity to the HVA system before installing or servicing thermostat or any part of the system.
1-877-654-9394. UP400 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com
UP400 Programmable Thermostat Installation Instructions & User Guide For Installation Help 1-877-654-9394 White-Rodgers.com 2011 Printed in China White-Rodgers 8100 West Florissant Avenue St. Louis, MO
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
Install Guide CT101. Caution. Caution
Install Guide CT101 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
T8000, T8001 Programmable Thermostat
T8000, T800 Programmable Thermostat INSTALLATIN INSTUTINS APPLIATIN The T8000, T800 Thermostats provide single-stage, programmable temperature control for 4 Vac heatingcooling systems with manual changeover
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
ACONT900AC43UA Communicating, Programmable Comfort Control
ACONT900AC43UA Communicating, Programmable Comfort Control OWNER S GUIDE Pub No. 69-1820-04 TABLE OF CONTENTS Page Contents 3 Features 4 Home Screen 6 Programming Your Heating and Cooling Schedule 14 Operating
How To Control A Thermostat
CONTENTS Installation Instructions for Heating & Air Conditioning 1F72 5/2 Day Programmable Heat Pump Thermostat Preparations... 1 Thermostat Details... 1 Removing Old Thermostat... 1-2 Mounting and Wiring...
HEAT HEAT COOL HEAT PUMP COOL
OWNER S MANUAL RESIDENTIAL THERMOSTAT P/N P374-1800 HEAT COOL HEAT PUMP Su AUTO 0I20: Pm 74 COOL HEAT 27 7-DAY MABLE DIGITAL THERMOSTAT 3 Configurable Outputs Accepts Optional Humidity Module: Control
QUICK INSTALLATION GUIDE
QUICK INSTALLATION GUIDE Read Installer Notes before removing cover from Thermostat. 1F85RF-275 Wireless Remote Kit INSTALLER NOTES IMPORTANT Do not apply power to the thermostat or wireless sensor until
1F82-0261 5/1/1 Day Programmable. 1F82-0261 Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1
Blue 2 Heat Pump Thermostat Heat Pump Installation and Operating Instructions Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING
CT3200 Programmable Thermostat
CT3200 Programmable Thermostat Welcome to the world of comfort and energy savings with your new Honeywell Programmable Thermostat. Your new thermostat will automatically control the temperature in your
1F82-261 Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION ELECTRICAL DATA Electrical Rating: 20 to
Installation Instructions
TP-PRH-A, TP-NRH-A Performance Series Edge Thermidistat Control Installation Instructions Programmable Control A07049 A07048 Non Programmable Control Designed and Assembled in the USA. NOTE: Read the entire
INSTALLATION REMOVE OLD THERMOSTAT ATTACH THERMOSTAT BASE TO WALL CHECK THERMOSTAT OPERATION BATTERY LOCATION
HITE-RDERS 1F86-244 Non-Programmable Electronic Digital Thermostat INSTALLATIN AND PERATIN INSTRUCTINS perator: Save these instructions for future use! FAILURE T READ AND FLL ALL INSTRUCTINS CAREFULL EFRE
SC 2201. Installation, Operation & Application Guide
SC 2201 Manual Changeover Non-Programmable Hardwired Non-Programmable Electronic Thermostat For use with Heat Pumps Up to 2-Stage Heat, 2-Stage Cool 30-Minute Power Loss Memory etention For use with 24
T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control
T Series arge CD Digital Thermostat 0/0 VAC -pipe/-pipe fan coil control Data sheet Application T digital thermostats are designed for application of -speed fan and s in fan coil system. Including: -pipe
Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat
Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat MOUNTING LOCATIONS Refer to the guidelines below and Fig. 1 5 for mounting locations of the Discharge and Return Air Temperature Sensors.
Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT
Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT Weekday, Saturday and Sunday Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT3500/CT3595 OWNER S GUIDE Para pedir
YOUR THERMOSTAT REPLACES Assemble tools required as shown below. HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED
1F85-275 Heating & Air Conditioning 5-1-1 Programmable/Non-programmable, Auto Changeover, Multi-Stage/Heat Pump Thermostat INSTALLATION INSTRUCTIONS Operator tor: Save these instructions for future use!
Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7
THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3
SINCE 1 8 8 6 AUTO SAVER 550. OwnerÕs Manual Model 44550
SINCE 1 8 8 6 AUTO SAVER 550 5: 7 2 2 3 2 OwnerÕs Manual Model 44550 Ask Your Local Retailer for Other Quality Products from unter Fans Air Purifiers umidifiers To locate your nearest unter Dealer, call
Blue Easy Reader Thermostat 1F95EZ-0671. Homeowner s Guide
Blue Easy Reader Thermostat 1F95EZ-0671 Homeowner s Guide Message to Homeowners Congratulations on choosing the Emerson Blue Easy Reader Thermostat. Blue Easy Reader is designed to be the easiest thermostat
its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
ComfortLink II Installation Guide. 3 Zone Panel (optional) 4 Zone Sensor with Display (optional) 5 Zone Sensor (optional) 6 Zone Dampers (optional)
18-HD64D1-3 ComfortLink II Installation Guide Other Installation Guides may be necessary, based on system configuration. A complete list of other optional components is shown below. 1 Control 2 Relay Panel
Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.
Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual
APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!
Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. APPLICATIONS
WHITE-RODGERS COMFORT-SET 90 SERIES
INSTALLATI DESCRIPTI WHITE-RODGERS COMFORT-SET 90 SERIES MULTI-STAGE INSTALLATI/CFIGURATI This White-Rodgers Automatic Setback Digital Thermostat uses microcomputer technology to provide precise time and
RESIDENTIAL THERMOSTATS CLIMATEMASTER
ESIDENTIAL THEMSTATS LIMATEMASTE ETHEMAL HEATIN AND LIN MFT SYSTEMS ESIDENTIAL THEMSTAT PDUT UIDE THE LBAL LEADE esidential Thermostats 3.30 in [83.8mm] Fan: turns continuous fan FF or N 0.8 in Depth
T-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
Installation Instructions
TP --- PAC, TP --- PHP TP --- NAC, TP --- NHP Performance Series AC / HP Thermostat Installation Instructions A07049 Programmable Control A07048 Non-Programmable Control Designed and Assembled in the U.S.A.
Installation Guide. Prestige IAQ with Equipment Interface Module. RedLINK to Equipment Interface Module. RedLINK to TrueZONE Wireless Adapter
TM TM TM Prestige IAQ with Equipment Interface Module Installation Guide edlink to Equipment Interface Module 2 Wires for Power O edlink to TrueZONE Wireless Adapter 2 Wires for Power eference to key features
PSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA www.luxproproducts.com
PSPA711a LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS 52070 1 COMPATIBILITY...................................... 2 2 FEATURES............................................ 2 3 ELECTRICAL RATINGS................................
Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
Mode Switch. Fan Switch Menu button Program button
Operation 3M-30 Day Time of day Target Temperature Time Slot Touch Screen Current Room Temperature Thermostat Mode Statement of use: The 3M-30 can be used with millivolt, 24VAC, single and 2 stage conventional
T8611G Chronotherm IV Deluxe Programmable Heat Pump Thermostat
T8611G Chronotherm IV Deluxe mable Pump Thermostat PRODUCT DATA APPLICATION The T8611G Chronotherm IV Deluxe mable Pump Thermostat provides electronic control of 24 Vac single-zone heat pump systems. FEATURES
VisionPRO 8000 with RedLINK
VisionPRO 8000 with RedLINK PRODUCT DATA Customizable Service Reminders Set up to 10 service reminders. Choose from the pre-set options or customize your own. Reminders can be based on date or the outdoor
ELECTRIC POSITION for electric heat, then confirm with Fan Test below.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
Nest Learning Thermostat Pro installation & configuration guide
Nest Learning Thermostat Pro installation & configuration guide Need help? Help online: http://support.nest.com/certified Nest Certified Professional support: 1-855-VIP-NEST (1-855-847-6378) Hours: 5am-9pm
Heating and Cooling Basics Thermostat Control
Heating and Cooling Basics Thermostat Control UNI-LINE PRODUCT KNOWLEDGE 2012 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL
Installation Questions
Installation Questions How do I determine what type of heat I have? There may be several ways to determine what type of heat you have. First, if you can access the unit that is responsible for creating
PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.
Product Name: CT101 Document Title: CT101 Operation Guide Document Type Code: IBOE Part Number: 1202-004-002 20apr12 Iris inclusion text added mtf 9apr12 bs edits mtf 14mar12 ch edits mtf 13mar12 initial
Installation Instructions
Installation Instructions Model TSTATG2111 Use with most systems: 2-Heat, 1-ool 1- Day Prog ram m ab l e Digital Thermostat u p t o 2 - H e a t & 1 - o o l ontrol up to 2 Heat & 1 ool Stages Backlit Display
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
How To Set Up A Furnace Pump
ork etail System Specific iring Diagrams January 2012 Using Honeywell hermostats Index for Low Voltage iring Affinity Units utdoor Indoor System Description Page ZH 2 Stage HP AV or MV Variable Speed Air
Communicating Wall Control Installation Manual TSTAT0101SC
Communicating Wall Control Installation Manual TSTAT0101SC U.S. Patent No. 7,243,004 U.S. Patent No. 7,775,452 616 01 1017 02 08/07/12 Safety Considerations... 7 Introduction... 8 Quick Start... 9 Set
1F87-361 Programmable Electronic Digital Thermostat INSTALLATION AND OPERATION INSTRUCTIONS
1F87-361 Programmable Electronic Digital Thermostat INSTALLATIN AND PERATIN INSTRUCTINS perator: Save these instructions for future use! FAILURE T READ AND FLL ALL INSTRUCTINS CAREFULL EFRE INSTALLIN R
1F95-0671 7 Day 5/1/1 Day Non-Programmable. Yes
Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. Blue Universal
Safety & Installation Instructions
Home omfort ontrol Model 8910 READ AND SAVE THESE INSTRUTIS Safety & Installation Instructions Table of contents Installation Thermostat installation location recommendations.. 2 Thermostat mounting...
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
INSTALLATION MANUAL RS4220 RS5220 RS6220 RS4110 RS5110 RS6110
RS4110 RS5110 RS4220 RS5220 RS6220 INSTAATIN MANUA 352-00060-001 Rev. A RS4000 Series RS5000 Series RS6000 Series Thank you for purchasing a Robertshaw thermostat. This manual will describe how to install
REMOTE CONTROL MANUAL
REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read
1 For All Non-Programmable Digital Thermostat
OWNER'S MANUAL P/N P474-0100 1 For All Non-Programmable Digital Thermostat TOTALINE 68 Dual Setpoint Very easy to program Thermoglow Backlight No batteries required Auto-Changeover Locking Keypad Meets
T822, TS822 Heating/Cooling Thermostats
T8, TS8 Heating/Cooling Thermostats FEATUES PODUCT DATA T8A, D, F and TS8A control heating systems. T8C, E control cooling systems. T8G controls heating or cooling systems. T8F provides Auto-On System
37-7498. Professional Contractor INSTALLATION GUIDE
37-7498 Professional Contractor INSTALLATION GUIDE Wireless Setup Connect Exit Next Exit 3 EASY STEPS Installing Sensi thermostat isn t that different than installing a non Wi-Fi thermostat. 1. Install
1F78 CAUTION CONTENTS YOUR THERMOSTAT REPLACES PREPARATIONS. Installation Instructions for. Heating & Air Conditioning. Non-Programmable Thermostat
CNTENTS Installation Instructions for Heating & Air Conditioning 1F78 n-programmable Thermostat Preparations... 1 Thermostat Details... 1 Removing ld Thermostat... 1 Mounting and iring... 2 Check Thermostat
SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY
RV Products Division SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976A376 (1-11) TABLE OF CONTENTS
Operating Manual. Prestige THX9000 Touch-screen Thermostat Thermostat à écran tactile Termostato con pantalla táctil
Operating Manual Prestige THX9000 Touch-screen Thermostat Thermostat à écran tactile Termostato con pantalla táctil BE CAREFUL! Never use sharp instruments, such as a pencil or pen, to press touchscreen
The Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control.
The Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control. These units feature mercury free non lead based electronic
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
Operation 8022C. Customer Support: 888-515-2585 or Visit our webiste www.ritetemp-thermostats.com Made In China 401-006 OFF FAN HEAT COOL AUTO ON
Operation 8022C HEAT O AN HEAT COOL AUTO ON HEAT O AN HEAT COOL AUTO ON Customer Support: 888-515-2585 or Visit our webiste www.ritetemp-thermostats.com Made In China 401-006 Operation 8022C TEMP UP Time/
RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G
Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling
FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7
FAQs Conserve package Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Gateway Can I have someone install my system for me? If you are concerned
Wireless and Prestige Comfort Systems. Frequently Asked Questions Guide
Wireless and Prestige Comfort Systems Frequently sked uestions Guide TM RedLINK Wireless Technology TM The Description What is RedLINK? RedLINK is the first wireless protocol developed specifically for
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.
INSTALLER S SYSTEM SETUP GUIDE
2009 Lennox Industries Inc. Dallas, Texas, USA INSTALLER S SYSTEM SETUP GUIDE icomfort Thermostat Touch Screen Programmable Communicating Thermostat CONTROLS 506052 01 11/09 Litho U.S.A. Shipping and Packing
Operation Guide 3M-22
Operation Guide 3M-22 TEMP UP Target Temp Time Reset TEMP DOWN Control Panel Heat/Cool Mode Switch Fan Switch Battery Compartment Statement of use: The 3M-22 can be used with - millivolt, 24VAC single
Wireless Solutions. Application Selection Guide
Wireless Solutions Application Selection Guide THERMOSTATS ZONING AIR CLEANERS HUMIDIFIERS DEHUMIDIFIERS UV SYSTEMS VENTILATION WATER SOLUTIONS COMBUSTION RedLINK Wireless Systems TrueZONE Panel Return
RedLINK Wireless Comfort Systems. RedLINK Connects.
RedLINK Wireless Comfort Systems RedLINK Connects. TM THERMOSTATS ZONING AIR CLEANERS HUMIDIFIERS DEHUMIDIFIERS UV SYSTEMS VENTILATION WATER SOLUTIONS wireless TM Your Customers Are Connected. Wireless.
Single Zone LCD Thermostat Operating Instructions
Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip
Proliphix Internet Managed Thermostat (IMT) Installation Guide
Proliphix Internet Managed Thermostat (IMT) Installation Guide December 2011 Technical Support Technical Support is available through the Proliphix partner from whom you purchased your product. For technical
INSTALLATION AND OPERATION MANUAL
RCS MODEL ZC4 4 ZONE HVAC INSTALLATION AND OPERATION MANUAL DCN: 141-0020-02 /0/03 INTRODUCTION The 4 Zone HVAC Controller series allows up to 4 standard electronic thermostats to independently control
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps
HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps Operation and Maintenance Manual Model: 71028004 Applies to: Single Circuit Water-to-Water Twin Circuit Units Without DDC Controls MAMM WHSP
Operator: Save these instructions for future use!
WHITE-RDERS 1F58-72 Low Voltage Multi-Stage Heat PumpThermostat INSTALLATIN INSTRUCTINS perator: Save these instructions for future use FAILURE T READ AND FLLW ALL INSTRUCTINS CAREFULLY EFRE INSTALLIN
Emergency Heat slide switch on the panel or an external switch. Do not use the panel switch or the external switch if Dip switch #4 is set to HP.
Installation Instructions The ED4 is a 4-zone panel that can control gas/ electric, hydronic, electric and both conventional and dual fuel heat pumps with multi-stage heating and cooling. Low cost heat-cool
UV100A Ultraviolet Air Treatment System
UV100A Ultraviolet Air Treatment System INSTALLATION INSTRUCTIONS APPLICATION When installed in forced air heating and cooling systems, the UV100A Ultraviolet Air Treatment System kills airborne microorganism
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
BUSINESS. Elektronisches Türschloss. Installation and User Manual. www.burg-waechter.de. Ingeniously safe. Ingeniously simple.
Elektronisches Türschloss BUSINESS Set 5011 PINCODE Set 5012 FINGERSCAN Set 5013 E-KEY Ingeniously safe. Ingeniously simple. BA/MA TSE Set 5000 dp/fsc 04/2012 Installation and User Manual BURG-WÄCHTER
Technical support is also available by email or by phone: [email protected] 1.877.932.6233 (North America) 1.647.428.2220 (International)
Installation guide Welcome! If you have questions, we have answers. Visit ecobee.com/support/ecobee3 for tutorials, how-to videos and FAQs. Technical support is also available by email or by phone: [email protected]
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English. 1-800- RAIN BIRD (800-724-6247) or visit www.rainbird.
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump
R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully