Install Guide 3M-50. Caution. Caution
|
|
|
- Daniel Holt
- 10 years ago
- Views:
Transcription
1 PG 1 Install Guide 3M-50 aution Your thermostat is a precise instrument, handle it with care. Turn off electricity to the HVA system before installing or servicing thermostat or any part of the system. Do not turn electricity back on until work is completed. Do not short (jumper) across electric terminals at the control on the furnace or air conditioner to test the system. This may damage the thermostat. All wiring must conform to local codes and ordinances. This thermostat is designed for use with 3 AA alkaline batteries and/or 24 VA wire (or a A or D source) and millivolt gas systems. Each thermostat relay load should be limited to 1.0 amp; higher amperage may cause damage to the thermostat. Save Energy button Power Grid status indicator Reset button HVA selection switches top cover RADIO 1 LINK TARGET TEMP PM DAY F AUTO OOL ire terminals Mode button Fan button MENU button aution To avoid electrical shock and to prevent damage to the furnace, air conditioner, and thermostat, disconnect the power supply before beginning work. This can be done at the circuit breaker. bottom cover Touch screen PROG button ENGLISH
2 PG 2 TOOLS You will need a small Phillips screwdriver and a drill with 3/16-in. (4.8mm) bit for wall mounts. LOATION Replacement installations - mount the 3M-50 in place of the old thermostat. A new location will require moving your wiring. For new installations and relocating the 3M-50 - follow the guidelines listed below: Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is used often. Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a lamp, radio, television, radiator register, fireplace; near hot water pipes in a wall; or near a stove on the other side of a wall. Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in a draft from a stairwell, door, or window. Do not locate in a damp area. This can lead to corrosion that will shorten thermostat life. Do not locate where air circulation is poor, such as: in a corner, an alcove; behind an open door. Do not install the 3M-50 until all construction and painting has been completed. This thermostat does not require leveling. Good 5ft. (1.5m)
3 REMOVE OLD UNIT Switch OFF electricity to the HEATING and OOLING systems. Then follow these steps: Remove cover from old thermostat. Most are snap-on types and simply pull off. Some have locking screws on the side or front. These must be loosened. DO NOT remove wires. Note the letters printed near the terminals. Attach labels (enclosed) to each wire for identification. aution Read instructions carefully before removing any wiring from existing thermostat. ires must be labeled before they are removed. THERE IS NO STANDARD OLOR ODE. hen removing wires from their terminals, ignore the color of the wires and LABEL THEM by the lettered terminal where they were screwed. Label the wires one at a time. You must label all the wires before you proceed. ith all wires labeled, remove them from the old unit. Make sure the wires do not fall back inside the wall. You can wind them around a pencil to keep them from falling. Loosen all screws on the old thermostat and remove it from the wall. G PG 3
4 PG 4 hat wires do you have? Make sure your wires are labeled. This may require you to find the other end connection for each wire on your heating or air conditioning equipment and read the label there. Refer to the ire Reference page at end of install section for better understanding of wire labels from different HVA system makers. IMPORTANT: The 3M-50 runs on 3 AA alkaline batteries and/or the wire if available. If you do not have a wire you can run a new wire from the HVA or use a standard 12-24V [A or D] wall transformer. A constant power source is required when using a radio module. IMPORTANT: If you have both RH and R you need to remove the jumper wire between these 2 terminals. Prepare ires Jumper wire Y RH R G A from HVA System 2.6" ire Terminals Y RH Please follow these guidelines for safe and secure wire connections: You will need at least 2.6 of wire for each of your connections to the 3M-50. If you do not have enough wire, splice additional wire to allow enough slack. Terminals accept wires from 16-22awg. Fan out wires below the hole as shown. Remove insulation 1/8 from the tip of each wire. hen handling, take care not to damage the labels for each wire. G
5 Find the step-by-step diagram for your system RH From Furnace From Furnace from HVA 2 ire Heat RH RH A from HVA RH 3 ire Zoned Hot ater Go To Page 16 A B or O Y RH G from HVA From Furnace B O or 4 ire Heat Pump w/o Aux Heat Y Go To Page 13 RH G RH G from HVA From Furnace 3 ire Heat RH G Y RH G From Furnace 4 ire Heat/ool Y RH B or O 2 Y RH G From Furnace B O or 5 ire Heat Pump w/ Aux Heat 2 Y RH G G Y RH R G From Furnace Y RH 5 ire Heat/ool Go To Page 13 Go To Page 14 Go To Page 14 from HVA from HVA R 2 Y Y2 RH G from HVA From Furnace from HVA 2 Y Go To Page 15 Go To Page 15 Go To Page 16 RH G 2 stage ool 2 stage Heat Y2 G Select the referenece page with your wiring diagram and set-up information below. The -wire is optional but prefered for all installations [shown dotted in diagrams]. Some radio modules will require the 24VA -wire power. If your combination of wires is not above you can use the wiring table at the end if the install section to determine your connections. ontact customer support for help. PG 5
6 from HEAT/OOL system PG 6 Fan out wires as illustrated with 3M-50 below the wall opening. As in the example: fan out the wires so that the wire is above the terminal, the above the. This allows the 3M-50 to fit snugly to the wall. Y G RH aution Do not allow wires to touch each other or parts on thermostat. B O 2 Y Y2 RHRG A ires will position behind the 3M-50 and up over the terminal area. Do not bunch wires behind the 3M-50. Feed any slack back into the wall opening. onnect Your ires onnect labeled wires only to a terminal with the same letter label. Insert the wire in the terminal well and tighten the screw securely. NOTE: If you wish you can mount the 3M-50 to the wall first, and then connect the wires. The 3M-50 can be externally powered with a power source rated from 12V to 24V, A or D, at 300ma or greater. If used, connect to the and RH terminals (no polarity).
7 Mount the 3M-50 to all 1. Hold the 3M-50 against the wall, with the wires coming over the top; above terminal block. The 3M-50 will cover the hole in the wall. 2. Position 3M-50 for best appearance. 3. Attach the 3M-50 to the wall with the screws provided. 3M If you are mounting the 3M-50 to sheet rock or if you are using the old mounting holes, use the plastic anchors provided. 5. Mark first and drill a 3/16-in.(4.8mm) hole for the insert at each screw location, then mount the unit. from HEAT/OOL system Y RH G all ires B O 2 Y Y2 RHRG A Place wires like this B O 2 Y Y2 RHRG A all anchor Screw to wall PG 7
8 PG 8 HVA Selection NORM HP GAS ELE RESET Set the HVA TYPE switch in the NORM position if you have conventional natural gas, propane, oil, or electric heat. If you have a HEAT PUMP system set the HVA TYPE switch to HP. Set the HEAT SOURE switch in the GAS position if you have normal gas or oil heat or if you have a heat pump with gas or oil auxiliary heat. Put the HEAT SOURE in the ELE position if you have normal electric heat or if you have a heat pump with electric auxiliary heat. HVA TYPE HEAT SOURE Install 3 AA Batteries Install 3 AA alkaline batteries [required] following the marked polarity in the battery compartment. Put the lower battery in negative end first against the spring, then push the positive end in. Then insert the last 2 batteries as shown. IMPORTANT: Press the RESET button (under top cover) to implement the HVA switch selections. 3 AA AA 1 AA 2 ith all the wires connected it is time to turn the A power back on. Do this at the breaker you used to switch it off. The 3M-50 will power-up in the OFF mode. Your 3M-50 is not configured to operate your HVA system yet. You must now configure your thermostat for your HVA system.
9 aution Special Battery arning Always replace the batteries as soon as the Low Batt flashes. The thermostat is a battery powered device. You must be responsible to replace batteries before they run out. Failure to replace batteries can result in overheating or excessive cooling of your house. Even if the Low Batt indicator does not flash, you should always replace the batteries at least once a year. Replacing the batteries also helps to prevent leakage that can corrode and damage the thermostat. If you are leaving your home for a month or more, you should replace the batteries as a precaution against battery failure in your absence. Always use new alkaline batteries. Failing to replace the batteries, when necessary, could cause the thermostat to lose power or malfunction. If the thermostat loses power, then the thermostat will not control the temperature which could result in your HVA system not functioning as you intended and lead to possible damage from overheating or excessive cooling. If the thermostat batteries fail with the heat OFF, this can result in NO HEAT and possible frozen or broken pipes and water damage. If the thermostat batteries fail with the cool OFF, this can result in NO OOL and could cause possible damage or excessive temperatures. PG 9
10 PG 10 HVA Setup on Screen IMPORTANT: Make sure the 3M-50 is powered up and the mode is set to OFF. HVA selection switches must be set first [pg 8]. ith mode in OFF press MENU and touch HVA SET UP. Use +/- icons to select HVA SET UP number on screen. The LD display will show your selection and indicate the number of stages you have selected. During setup, 2nd stage will blink when both heat and cool have 2nd stages. HVA SETUP HEAT 2ND STG OOL If you have a Normal HVA system and you want fast temperature recovery... HEAT and OOL select 1 2 stage HEAT, 1 stage OOL select 2 2 stage HEAT, 2 stage OOL select 3 If you want efficient [but slower] recovery... 2 stage HEAT, 1 stage OOL select 4 2 stage HEAT, 2 stage OOL select 5 If you have a HEAT PUMP HVA system... HEAT PUMP with AUX heat (fast recovery) HEAT PUMP with AUX heat (efficient recovery) HEAT PUMP no AUX heat select A select b select NOTE: For 2 stage systems your 3M-50 can recover from a temperature setback in 2 ways: 1] Fast Recovery - This uses your 2nd stage to bring the house to Target Temperature. This may use slightly more energy. 2] Efficient Recovery -This uses the 2nd stage to bring your house to within a few degrees of the Target Temperature and then uses the 1st stage to go the last bit. (See setting the differential in the operating guide). This is more efficient.
11 Test Installation Follow these procedures to verify you have correctly installed the 3M-50. TO HEK FAN (If you connected the G wire): Press the fan button to turn the fan ON. Verify that air is blowing from the system. Press the fan button again to return to AUTO. TO HEK HEAT Set the mode to HEAT by pressing the MODE button until HEAT is displayed. Touch the temperature display to bring up the MANUAL screen. Touch the + icon and raise the Target Temperature to 90 o F; allow the system 2 minutes to respond. Verify that heat is blowing from the system. Return the Target Temperature to a nomal setting. Return mode to OFF by pressing the mode button. If you have a heat pump, leave in off for 4 minutes before checking OOL. TO HEK OOL (do not operate A if the outside temp is below 65 o F) Set the mode to OOL by pressing the MODE button until OOL is displayed. Touch the - icon to lower cool Target Temperature to 50 o F. Allow the system 5 minutes to respond. Verify that cool air is blowing from the system. Return mode to OFF. PG 11
12 PG 12 ongratulations, you have successfully installed your unit. Please proceed to the OPERATING Guide to initialize the 3M-50. IMPORTANT: After you have labeled and connected your wires, followed the correct HVA setup, and your system still does not operate, contact support at www. radiothermostat.com/filtrete or am-midnight EST. STATEMENT OF USE: This thermostat can be used with 3 AA batteries, 24VA ( wire), 24VA adapter, heating and cooling systems and also millivolt heating. It cannot be used with line voltage systems. This thermostat is digital and your desired heat or cool temperatures can easily be set on the large touch screen with the +/- buttons. A minimum 4 minute off time protects the compressor from damage. This thermostat runs on 3 AA batteries. The 3M-50 can be externally powered with a power source rated from 12V to 24V, A or D, at 300ma or greater. If used, connect to the and RH terminals (no polarity). The 24VA wire is the other side of the 24VA heating transformer and can be found where the other thermostat wires connect at the wall or at the furnace. Do not use the common or ground side of the line voltage. RADIO 1 LINK TARGET TEMP PM DAY F AUTO OOL MODE control FAN control
13 Step-by-Step iring Diagrams 2 ire Heat GAS MILLIVOLT or 24VA system STEP 1 - onnect the R (or RH) wire to the RH terminal. This connects the heat power. STEP 2 - onnect the wire to the terminal. This connects the heat. STEP 3 - Set HVA selection switches to NORMAL and GAS. RADIO POER Your heater is now connected to the 3M-50. Please Go To Page 6 Thermostat Terminals HVA SYSTEM H B O 2 Y Y2 RH R G A R 3 ire Heat STEP 1 - onnect the R (or RH) wire to the RH terminal. This connects the heat power. STEP 2 - onnect the wire to the terminal. This connects the heat. STEP 3 - onnect the G wire to the G terminal on the thermostat. This connects the fan. STEP 4 - Set HVA selection switches to NORMAL and: If you have gas or oil heat, set the HEAT TYPE to GAS. If you have electric heat, set the HEAT TYPE to ELE. Your system is now connected to the 3M-50. Please Go To Page 6 Thermostat Terminals REMOTE POER HVA SYSTEM R G H B O 2 Y Y2 RH R G A PG 13
14 PG 14 Y RH G 4 ire Heat/ool STEP 1 - onnect the wire to the terminal. This connects the heat. STEP 2 - onnect the Y wire to the Y terminal. This connects the cooling compressor. STEP 3 - onnect the RH or R wire to the RH terminal. This connects the power. STEP 4 - onnect the G wire to the G terminal on the thermostat. This connects the fan. STEP 5 - Set HVA selection switches to NORMAL and: If you have gas or oil heat, set the HEAT TYPE switch to GAS. If you have electric heat, set the HEAT TYPE switch to ELE. Your HVA system is now connected to the 3M-50. Please Go To Page 6 Thermostat Terminals REMOTE POER HVA SYSTEM Y R G H B O 2 Y Y2 RH R G A Y RH R G 5 ire Heat/ool STEP 1 - onnect the wire to the terminal. This connects the heat. STEP 2 - onnect the Y wire to the Y terminal. This connects to the cooling compressor. STEP 3 - Disconnect the jumper between RH and R terminals. STEP 4 - onnect the RH wire to the RH and the R wire to the R terminals. This connects power. STEP 5 - onnect the G wire to the G terminal. This connects the fan. STEP 6 - Set HVA selection switches to NORMAL and: If you have gas or oil heat, set the HEAT TYPE to GAS. If you have electric heat, set the HEAT TYPE to ELE. REMOTE POER HVA SYSTEM Y RH R G Your HVA system is now connected to the 3M-50. Please Go To Page 6 Thermostat Terminals H B O 2 Y Y2 RH R G A
15 4 ire Heat Pump (heat/cool) without Auxiliary Heat STEP 1 - onnect O wire to the O terminal or B wire to the B. This connects the change-over valve. If you have both O and B - connect only the O wire to the O terminal and DO NOT connect B to B terminal (see wire reference under Trane for B wire terminal). STEP 2 - onnect the Y wire to Y terminal. This connects the compressor. STEP 3 - onnect the R wire to RH. This connects the power. STEP 4 - onnect the G wire to the G. This connects the fan. STEP 5 - Set HVA selection switch to HEAT PUMP and set the HEAT. TYPE to ELE. Your HVA system is now connected to the 3M-50. Please Go To Page 6 5 ire Heat Pump w/ Aux Heat STEP 1 - onnect O wire to the O terminal or B wire to the B. This connects the change-over valve. If you have both O and B - connect only the O wire to the O terminal and DO NOT connect B to B terminal (see wire reference under Trane for B wire terminal). STEP 2 - onnect the 2 wire to 2 terminal. This connects the auxiliary heat. STEP 3 - onnect the Y wire to Y terminal. This connects the compressor. STEP 4 - onnect the R wire to RH terminal. This connects the power. STEP 5 - onnect the G wire to G terminal. This connects the fan. STEP 6 - Set HVA selection switches to heat pump and: If you have gas or oil auxiliary heat, set the HEAT TYPE to GAS. If you have electric auxiliary heat, set the HEAT TYPE to ELE. Your HVA system is now connected to the 3M-50. Please Go To Page 6 Terminals Terminals or POER HEAT PUMP SYSTEM O or B Y R G B O 2 Y Y2 RH R G A or REMOTE POER B 2 Y R G H B O 2 Y Y2 RH R G A HEAT PUMP SYSTEM O or PG 15
16 PG 16 2 Stage Heat and 2 Stage ool STEP 1 - onnect the wire to the terminal. This connects the 1st Stage of HEAT. STEP 2 - onnect the 2 wire to the 2 Terminal. This connects the 2nd Stage of HEAT. STEP 3 - onnect the Y wire to the Y terminal. This connects the 1st Stage of OOL. STEP 4 - onnect the Y2 wire to the Y2 terminal. This connects the 2nd Stage of OOL. STEP 5 - onnect the RH or R wire to the RH terminal.this connects the power. STEP 6 - onnect the G wire to the G terminal. This connects the fan. STEP 7 - Set HVA selection switches to NORMAL and: If you have gas or oil heat, set the HEAT TYPE to GAS. If you have electric heat, set the HEAT TYPE to ELE. Your HVA system is now connected to the 3M-50. Please Go To Page 6 RH [A?] 3 ire Zoned Hot ater For Solenoid valve or Motor valve connect the wires based on diagrams below to the correct terminal on the 3M-50. USE ONLY IN HEAT MODE. The third wire on your valve may be called 6, Y, or G (see page 18). Motor Valve R A Solenoid Valve A R Terminals REMOTE POER HVA SYSTEM 2 Y Y2 RH R G H B O 2 Y Y2 RH R G A H B O 2 Y Y2 RH R G A Terminals H B O 2 Y Y2 RH R G A Terminals
17 ire Reference hart Possible ires R or V or VR RH or 4 R 2 3 Y Y2 G or F or X H DH EX B O B and O E L T hat They ontrol RH and R Single power for HEAT and OOL RH Power for HEAT (RH not connected to R jumper clip removed) R Power for OOL (RH not connected to R jumper clip removed) Heat control 2 2nd stage HEAT or heat pump auxiliary heat 3 3rd stage HEAT or 2nd stage of 2 stage auxiliary heat Y OOL control or 1st stage compression for heat pump Y2 2nd stage OOL control or 2nd stage compression for a heat pump G FAN control 24VA power (to power thermostat) NOTE: TRANE uses B for this connection H External Humidifier DH External De-Humidifier EX external fresh air baffle B Heat pump changeover (cool to heat, powered in heat) O Heat pump changeover (heat to cool, powered in cool) IMPORTANT: If there are both B and O wires (Trane pump products) DO NOT ONNET B to B terminal, connect B to terminal. If not a Trane product tape off B. n/a Emergency heat (do not connect, tape off) n/a System monitor (do not connect, tape off) n/a Outdoor sensor (do not connect, tape off) PG 17
18 PG 18 Lennox Heat Pump V or VR or R M or Y Y or or 2 F or G R or O X or X2 or RH Power for HEAT Y OOL control 2 2nd stage HEAT G Fan control O Trane Products [American Standard] B 24VA power (to power thermostat) or 1 2 2nd stage HEAT X2 Emergency heat (do not connect, tape off) Zoned Hot ater 2 wire Your ires R 3 ire Motor Driven Valves R or 5 or 4 Y or G or 6 (the 3rd wire) Thermostat Terminal RH RH (power) (heat ON) A (heat OFF) 3 ire Solenoid Valves R RH (power) A (heat ON) Y or G (the 3rd wire) (heat OFF) ustomer support: [email protected] or
Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.
Install Guide CT100 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
Install Guide CT101. Caution. Caution
Install Guide CT101 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
How To Control A Thermostat
CONTENTS Installation Instructions for Heating & Air Conditioning 1F72 5/2 Day Programmable Heat Pump Thermostat Preparations... 1 Thermostat Details... 1 Removing Old Thermostat... 1-2 Mounting and Wiring...
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.
Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual
ELECTRIC POSITION for electric heat, then confirm with Fan Test below.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
HEAT PUMP PROGRAMMABLE THERMOSTAT
HEAT PUMP PROGRAMMABLE THERMOSTAT SA PM 3 COOL TEMP Form 44014-01 r010408 Model 43168 Owners Manual 1 Congratulations! Heat Pump Programmable Thermostat Model 43168 THERMOSTAT CONTROLS Switches & Buttons...15
Installation and Operation Manual Environ TM Smart Thermostat
Installation and Operation Manual Environ TM Smart Thermostat 2 Copyright Enphase Energy Inc. 2010 141-00010 Rev 01 Contact Information Enphase Energy Inc. 201 1 St Street Petaluma, CA 94952 Phone: 707-763-4784
Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types
Installation Guide LR-HWLV-HVAC TouchPRO Wireless Touchscreen Thermostat System Types Gas, oil, or electric heat with air conditioning Warm air, hot water, high efficiency furnaces, heat pumps, steam,
1F82-261 Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION ELECTRICAL DATA Electrical Rating: 20 to
Safety & Installation Instructions
Home omfort ontrol Model 8910 READ AND SAVE THESE INSTRUTIS Safety & Installation Instructions Table of contents Installation Thermostat installation location recommendations.. 2 Thermostat mounting...
Installation Questions
Installation Questions How do I determine what type of heat I have? There may be several ways to determine what type of heat you have. First, if you can access the unit that is responsible for creating
Installation Instructions
Installation Instructions Model TSTATG2111 Use with most systems: 2-Heat, 1-ool 1- Day Prog ram m ab l e Digital Thermostat u p t o 2 - H e a t & 1 - o o l ontrol up to 2 Heat & 1 ool Stages Backlit Display
Installation Guide. Programmable Thermostat TH6220D
Installation Guide Programmable Thermostat TH6220D Product Application This thermostat provides electronic control of 24 VAC single-stage and multi-stage heating and cooling systems, or 750 mv heating
1-877-654-9394. UP400 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com
UP400 Programmable Thermostat Installation Instructions & User Guide For Installation Help 1-877-654-9394 White-Rodgers.com 2011 Printed in China White-Rodgers 8100 West Florissant Avenue St. Louis, MO
FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7
FAQs Conserve package Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Gateway Can I have someone install my system for me? If you are concerned
SINCE 1 8 8 6 AUTO SAVER 550. OwnerÕs Manual Model 44550
SINCE 1 8 8 6 AUTO SAVER 550 5: 7 2 2 3 2 OwnerÕs Manual Model 44550 Ask Your Local Retailer for Other Quality Products from unter Fans Air Purifiers umidifiers To locate your nearest unter Dealer, call
1F82-0261 5/1/1 Day Programmable. 1F82-0261 Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1
Blue 2 Heat Pump Thermostat Heat Pump Installation and Operating Instructions Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING
Mode Switch. Fan Switch Menu button Program button
Operation 3M-30 Day Time of day Target Temperature Time Slot Touch Screen Current Room Temperature Thermostat Mode Statement of use: The 3M-30 can be used with millivolt, 24VAC, single and 2 stage conventional
YOUR THERMOSTAT REPLACES Assemble tools required as shown below. HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED
1F85-275 Heating & Air Conditioning 5-1-1 Programmable/Non-programmable, Auto Changeover, Multi-Stage/Heat Pump Thermostat INSTALLATION INSTRUCTIONS Operator tor: Save these instructions for future use!
QUICK INSTALLATION GUIDE
QUICK INSTALLATION GUIDE Read Installer Notes before removing cover from Thermostat. 1F85RF-275 Wireless Remote Kit INSTALLER NOTES IMPORTANT Do not apply power to the thermostat or wireless sensor until
Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types
Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:
INSTALLATION MANUAL RS4220 RS5220 RS6220 RS4110 RS5110 RS6110
RS4110 RS5110 RS4220 RS5220 RS6220 INSTAATIN MANUA 352-00060-001 Rev. A RS4000 Series RS5000 Series RS6000 Series Thank you for purchasing a Robertshaw thermostat. This manual will describe how to install
Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7
THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3
T-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
Technical support is also available by email or by phone: [email protected] 1.877.932.6233 (North America) 1.647.428.2220 (International)
Installation guide Welcome! If you have questions, we have answers. Visit ecobee.com/support/ecobee3 for tutorials, how-to videos and FAQs. Technical support is also available by email or by phone: [email protected]
General Information. Do programmable thermostats really save energy?
General Information Do programmable thermostats really save energy? Yes, programmable thermostats can save energy which in turn saves you money on your utility bill. The US Department of Energy states
Nest Learning Thermostat Pro installation & configuration guide
Nest Learning Thermostat Pro installation & configuration guide Need help? Help online: http://support.nest.com/certified Nest Certified Professional support: 1-855-VIP-NEST (1-855-847-6378) Hours: 5am-9pm
WHITE-RODGERS COMFORT-SET 90 SERIES
INSTALLATI DESCRIPTI WHITE-RODGERS COMFORT-SET 90 SERIES MULTI-STAGE INSTALLATI/CFIGURATI This White-Rodgers Automatic Setback Digital Thermostat uses microcomputer technology to provide precise time and
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
TX9000TS SERIES SMART TEMP ELECTRONIC THERMOSTAT. Easy as 1 2 3 INSTALLATION AND OPERATING INSTRUCTIONS
SMART TEMP ELECTRONIC THERMOSTAT INSTALLATION AND OPERATIN INSTRUCTIONS Installs Easily Set Day & Time IMPORTANT! Please read all instructions carefully before beginning installation. Save them for future
37-7498. Professional Contractor INSTALLATION GUIDE
37-7498 Professional Contractor INSTALLATION GUIDE Wireless Setup Connect Exit Next Exit 3 EASY STEPS Installing Sensi thermostat isn t that different than installing a non Wi-Fi thermostat. 1. Install
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
Operation Guide 3M-22
Operation Guide 3M-22 TEMP UP Target Temp Time Reset TEMP DOWN Control Panel Heat/Cool Mode Switch Fan Switch Battery Compartment Statement of use: The 3M-22 can be used with - millivolt, 24VAC single
PSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA www.luxproproducts.com
PSPA711a LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS 52070 1 COMPATIBILITY...................................... 2 2 FEATURES............................................ 2 3 ELECTRICAL RATINGS................................
INSTALLATION REMOVE OLD THERMOSTAT ATTACH THERMOSTAT BASE TO WALL CHECK THERMOSTAT OPERATION BATTERY LOCATION
HITE-RDERS 1F86-244 Non-Programmable Electronic Digital Thermostat INSTALLATIN AND PERATIN INSTRUCTINS perator: Save these instructions for future use! FAILURE T READ AND FLL ALL INSTRUCTINS CAREFULL EFRE
REMOTE CONTROL MANUAL
REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Installation Guide. Prestige IAQ with Equipment Interface Module. RedLINK to Equipment Interface Module. RedLINK to TrueZONE Wireless Adapter
TM TM TM Prestige IAQ with Equipment Interface Module Installation Guide edlink to Equipment Interface Module 2 Wires for Power O edlink to TrueZONE Wireless Adapter 2 Wires for Power eference to key features
Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT
Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT Weekday, Saturday and Sunday Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT3500/CT3595 OWNER S GUIDE Para pedir
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL
CT3200 Programmable Thermostat
CT3200 Programmable Thermostat Welcome to the world of comfort and energy savings with your new Honeywell Programmable Thermostat. Your new thermostat will automatically control the temperature in your
Installation Instructions
TP-PRH-A, TP-NRH-A Performance Series Edge Thermidistat Control Installation Instructions Programmable Control A07049 A07048 Non Programmable Control Designed and Assembled in the USA. NOTE: Read the entire
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!
Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. APPLICATIONS
Operation 8022C. Customer Support: 888-515-2585 or Visit our webiste www.ritetemp-thermostats.com Made In China 401-006 OFF FAN HEAT COOL AUTO ON
Operation 8022C HEAT O AN HEAT COOL AUTO ON HEAT O AN HEAT COOL AUTO ON Customer Support: 888-515-2585 or Visit our webiste www.ritetemp-thermostats.com Made In China 401-006 Operation 8022C TEMP UP Time/
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.
Heating and Cooling Basics Thermostat Control
Heating and Cooling Basics Thermostat Control UNI-LINE PRODUCT KNOWLEDGE 2012 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
Thermostat Wire Adapter
elcome To ire Adapter INSTALLATION UIDE INTRODUTION Thanks for purchasing the idevices ire Adapter. This easy-to-follow guide will take you through the installation process, step by step. If at any time
HEAT HEAT COOL HEAT PUMP COOL
OWNER S MANUAL RESIDENTIAL THERMOSTAT P/N P374-1800 HEAT COOL HEAT PUMP Su AUTO 0I20: Pm 74 COOL HEAT 27 7-DAY MABLE DIGITAL THERMOSTAT 3 Configurable Outputs Accepts Optional Humidity Module: Control
COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions
COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming
Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions
Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Ducoterra Radiant Heating Panel Installation Manual
Ducoterra Radiant Heating Panel Installation Manual 1. Introduction Your new radiant heating panels are designed to heat living and working spaces rapidly and efficiently by radiant heating. Like the sun,
INSTALLATION AND OPERATION MANUAL
RCS MODEL ZC4 4 ZONE HVAC INSTALLATION AND OPERATION MANUAL DCN: 141-0020-02 /0/03 INTRODUCTION The 4 Zone HVAC Controller series allows up to 4 standard electronic thermostats to independently control
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control
T Series arge CD Digital Thermostat 0/0 VAC -pipe/-pipe fan coil control Data sheet Application T digital thermostats are designed for application of -speed fan and s in fan coil system. Including: -pipe
Energy Smart Electric Water Heater Controller
Installation, Operation and Troubleshooting Instructions Energy Smart Electric Water Heater Controller Table of Contents Installation and Setup, 2 Operation, 5 Troubleshooting, 7 Regulatory Notices, 11
Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
RESIDENTIAL THERMOSTATS CLIMATEMASTER
ESIDENTIAL THEMSTATS LIMATEMASTE ETHEMAL HEATIN AND LIN MFT SYSTEMS ESIDENTIAL THEMSTAT PDUT UIDE THE LBAL LEADE esidential Thermostats 3.30 in [83.8mm] Fan: turns continuous fan FF or N 0.8 in Depth
MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
SC 2201. Installation, Operation & Application Guide
SC 2201 Manual Changeover Non-Programmable Hardwired Non-Programmable Electronic Thermostat For use with Heat Pumps Up to 2-Stage Heat, 2-Stage Cool 30-Minute Power Loss Memory etention For use with 24
Proliphix Internet Managed Thermostat (IMT) Installation Guide
Proliphix Internet Managed Thermostat (IMT) Installation Guide December 2011 Technical Support Technical Support is available through the Proliphix partner from whom you purchased your product. For technical
SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY
RV Products Division SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976A376 (1-11) TABLE OF CONTENTS
NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.
Product Name: CT101 Document Title: CT101 Operation Guide Document Type Code: IBOE Part Number: 1202-004-002 20apr12 Iris inclusion text added mtf 9apr12 bs edits mtf 14mar12 ch edits mtf 13mar12 initial
Installer Guide smart connect
Installer Guide smart connect TM 7330 Wireless Remote Humidity Sensor Please read all instructions before proceeding. The wireless remote humidity sensor monitors the humidity passing through the return
OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump
R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013
Bulletin 30-34 / March 2013 INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES General The information on the following pages is to provide the installer the necessary information to properly install the
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
HOUSING QUALITY STANDARDS (HQS)
HOUSING QUALITY STANDARDS (HQS) Series 5 Electrical Safety And INSPECTIONS 5.01 ELS Revised 8-17-06 Electricity is Dangerous All electrical repairs should be made by licensed professionals. Touching any
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET
CM702 PROGRAMMABLE THERMOSTAT FEATURES Attractive slim, modern styling makes it ideal for location in any type of home. 24-hour heating program. Up to 4 daily independent time and temperature level changes
INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER
INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-360B Supersedes: 2100-360A File: Volume
QUICK REFERENCE. Wired remote controller BRC2E52C7 BRC3E52C7
QUICK REFERENCE BRCEC BRCEC BRCEC BRCEC Table of contents Page Operation General safety precautions Features and functions Name and function of switches Name and function of icons Description of the operation
LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual
CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel: 01825 733600 LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual Contents 1) Operation 2)
Air Conditioning Sign-Off Sheet
Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate
CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel
CHAPTER 4 UTILITY SYSTEMS ELECTRICAL Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if
Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)
UNIT OBJECTIVES Describe the concept of year-round air conditioning List three typical year-round air conditioning system types List the five ways to condition the air Determine airflow for a cooling system
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
Wireless 7 Day Programmable Room Thermostat
Wireless 7 Day Programmable Room Thermostat Cat. No. TRT037 Transmitter Receiver Operating & Installation Instructions What is a programmable room thermostat? an explanation for householders A programmable
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.
Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E. Basic Thermostat Types Many technicians have great difficulty understanding how to properly wire a thermostat or how to replace a thermostat with
Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English. 1-800- RAIN BIRD (800-724-6247) or visit www.rainbird.
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
1 For All Non-Programmable Digital Thermostat
OWNER'S MANUAL P/N P474-0100 1 For All Non-Programmable Digital Thermostat TOTALINE 68 Dual Setpoint Very easy to program Thermoglow Backlight No batteries required Auto-Changeover Locking Keypad Meets
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
AIR CONDITIONER INSTALLATION MANUAL
FRANCAIS ESPAÑOL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring