Catalog April Cam switches Complete products 10 A

Similar documents
3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A

Pendant control stations 6

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

RM4TG20 three-phase network control relay RM4-T - range V

R.C.C.B. s two-pole LEXIC

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Series 8146/5-V37 and Series 8150/5-V37

Safety dialogue solutions

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Manual motor starter MS116

Electronic overload relay EF19 and EF45

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Safety automation solutions

Electronic overload relay EF65, EF96 and EF146

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

P System Cubicles. Certified for more safety

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

ADM1TE 5/30A DIN rail single phase two wire energy meter

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Plug and Socket Devices CES 63 A Series 8579

ASSEMBLED SOCKET-COMBINATIONS

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Safety detection solutions

Type: DILM9 10(24VDC) Article No.:

Catalog. Modular DIN rail components Installation contactors

49 Series - Relay interface modules A. Features

Low Voltage Products. Switches Automatic Transfer Switches

Terminal Boxes Series 8146

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Cross-beam scanning system to detect slim objects. 100 mm in

Vario-Series Accessories

Technicaldata General

400 Series Buccaneer BUCCANEER POWER. bulgin

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

48 SERIES Relay interface modules 10 A

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Plug and Socket Devices SolConeX 16 A Series 8570

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Linear Luminaire with LED Series EXLUX 6402/2

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Quick Connect. quick - simple - efficient.

know-how Giant in distributing electricity for industry Prisma GK

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

General Informations 2 Technical data 3 Basic designs 4-8

Preventa Machine Safety Products

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Cable Plug acc. to DIN EN , Form A

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Bimetallic Overload Relay Specifications

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Linkeo 19" freestanding cabinets

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Pluggable interface relays CR-P Pcb relays

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

7000 Series Buccaneer

5SV Residual Current Protective Devices

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

RY2 miniature industrial relays

PSR The compact range Description

HERZ-Thermal Actuators

Technical catalogue. Modular DIN rail components Installation contactors

System pro M compact Miniature Circuit Breaker S 200/S 200 M

ELECTROMAGNETIC DISC BRAKES

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Breakers and Switches. Switches Change-over, bypass and transfer switches

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

OEM Relative and differential pressure switch type 605

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

D-Line Contactors, Overload Relays and Accessories

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

3/2-way Solenoid Valve, direct-acting, NC or NO

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Manual Motor Starter MS 116 up to 16 A Technical Data

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

Thermal-Magnetic Circuit Breaker M1-..

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

Transcription:

Catalog April Cam switches Complete products A

General Cam switches Complete products A The range of K cam switches ( A rating) comprises only complete switches. These products are more specifically designed for process control applications: b compact size, b easy to integrate with other Ø and Ø mm units, b selection functions. Complete products Front mounting switches b OFF-ON switches b stepping selector switches b changeover switches Single Ø. or Ø. mm hole fixing Mounting method Single Ø or Ø hole fixing Locking/unlocking of the body-head assembly by means of a lug Single Ø hole fixing Single Ø hole fixing page / References : pages / to / page / Schneider Electric

Characteristics Cam switches Complete products, A Front mounting, single Ø or Ø mm hole fixing With x mm front plate Environment Conforming to standards IEC/EN - IEC/EN -- Approvals culus Protective treatment Standard version: TC Ambient air temperature Operation: - + C Storage: - + C Electric shock protection Class II, conforming to IEC Degree of protection Mechanical durability IP conforming to IEC (operating head) IP (contact block) million operating cycles Contact block characteristics Rated operational characteristics AC-, A V A V A AC-A, AC- V A Short-circuit protection UL/Canada Heavy Duty A -phase / V. HP / V HP Single-phase / V. HP / V. HP AC-A -phase / V. kw Single-phase / V. kw / V. kw d.c. current Ie resistive load CartridgefuseAgG contact V A V. A V. A Conventional thermal current (Ith) A Rated insulation voltage (Ui) V, degree of pollution conforming to IEC - Contact operation Slow break Terminal referencing Conforming to CENELEC EN Rated impulse withstand voltage (U imp) kv conforming to IEC - Electrical reliability Failure rate < failure, for million operating cycles (c V PLC inputs) Cabling Screw and captive cable clamp terminals Clampingcapacity:x.mm page / References : pages / to / page / Schneider Electric

References Cam switches Complete products, A Front mounting, single Ø or Ø mm hole fixing With x mm front plate OFF-ON switches Wiring scheme and switching scheme Marking & switch position Number of poles Reference K-BACH K-AACH. K-BACH. -pole -pole -pole -pole K-CACH. K-DACH. Stepping switches, single-pole, with O position Wiring scheme and switching scheme Marking & switch position Number of poles Reference L +"" K-BQCH. L +"" K-CQCH. K-DQCH L +"" K-DQCH. page / page / page / Schneider Electric

References (continued) Cam switches Complete products, A Front mounting, single Ø or Ø mm hole fixing With x mm front plate Stepping switches, -pole, with O position Wiring scheme and switching scheme Marking &switch position Number of poles Reference L L +"" K-DQCH. K-DQCH L L +"" K-FQCH. Stepping switches, single-pole, without O position L K-CNCH. L K-DNCH. page / page / pages / Schneider Electric

References (continued) Cam switches Complete products, A Front mounting, single Ø or Ø mm hole fixing With x mm front plate Stepping switches, -pole, without O position Wiring scheme and switching scheme L L Marking & switch position Number of poles Changeover switch with spring return Wiring scheme and switching scheme Marking & switch position Reference K-FNCH. Number of poles Reference L L K-BTCH. K-BTCH K-FUCH Changeover switches with O position -pole L/ -pole -pole -pole Changeover switches without O position L/ K-BUCH. K-DUCH. K-FUCH. K-HUCH. K-BUCH. K-DUCH. K-FUCH. -pole -pole -pole -pole K-HUCH. page / page / pages / Schneider Electric

References (continued) Cam switches Complete products, A Front mounting, single Ø or Ø mm hole fixing With x mm front plate Voltmeter switches For measurement between phases and between phase and neutral Wiring scheme and switching scheme Marking &switch position Reference L L L N L-L L-N L-L L-L L-N L-N K-FMCH. K-FMCH V For measurement between phases, with O position L L L L-L L-L L-L K-DMCH. V Ammeter switches measurement points, with neutral position K-FMCH L L L PE A K-FMCH. page : / page / pages / Schneider Electric

References Cam switches Complete products, A Front mounting, single Ø or Ø mm hole fixing With x mm front plate Accessories Legend holders Description Sold in lots of Unit reference For Ø mm hole fixing With metallic finish legend ZN. ZN _ Accessories Description Colour Sold in lots of Unit reference Z Blanking plug Black Z. _ Nut wrench Z. Z page / page / page / Schneider Electric

Dimensions Cam switches Complete products, A Front mounting, single Ø or Ø mm hole fixing With x mm front plate Cam switches A e a a K-A, B K-C, D K-F K-H e : thickness of support. to. mm. Single Ø or Ø mm hole fixing,,,,,, Contact functions: how to understand the conventions used Link positions (factory mounted) Graphic representation of switching positions and spring return to O position L L L U V W Contact terminal reference number Contact closed Contact closed in positions and maintained between the positions Angular position of switch Sealed assembly for auto-maintain control Overlapping contacts page / page / References : pages / to / Schneider Electric

Schneider Electric Industries SAS Headquarters, bd Franklin Roosevelt F - Rueil Malmaison Cedex http://www.schneider-electric.com Owing to changes in standards and equipment, the characteristics given in the text and images in this document are not binding until they have been confirmed with us. Production : Schneider Electric Industries Photos : Schneider Electric Industries Printed by : CCI CT April