1 OEM Relative and differential pressure switch type 605 Pressure range Pa Type 605 pressure switches are specially developed for use in gas fired heating systems. There are more than 10 million switches in use worldwide. Produced on a fully automated production line. High setting accuracy and repeatability, combined with excellent reliability characterise a quality of switch above the industry norm. Fitting of the switch Fast mounting with snap bracket system Adjusting security High contact strength (typically 10 cn) and self cleaning roll operation contact Not susceptible to contact pollution Diaphragm design / material Better long term stability achieved though the use of a 2 component silicon diaphragm. Unique trapezoid diaphragm design provides for a better contact release and therefore a more accurate switching point Huba Control type Technical data subject to change - Edition 02/2012 1/5
2 Technical overview Pressure range Relative and differential Pa 1) Operating conditions Medium Air and neutral gases 2) Medium / ambient ÀC Temperature Storage ÀC < +85 ÀC 5000 Pa Tolerable overload on one side ÀC 1500 Pa Smallest turn on pressure of 20 Pa 3) Smallest switching differential 8 Pa Materials in contact with the medium Sensor Silicone LSR Case PC Lexan 500R 4) Electrical overview Switching load See Nominal loading limits Contact system Changeover switch Service life Mechanically > 10 6 switching cycles Protection standard Not mounted IP 00 With contact safety guard IP 30 With cover, without seal IP 54 With cover and seal IP 65 Reproducibility Between Electrical connection AMP connector 5) Pressure connections Pipe Orifice installed for damping pulsating pressure at P1, P2 (option) Mounting instructions Installation arrangement Mounting μ 1 Pa 6.3 mm 4.8 mm ± 6.2 mm Please indicate installation arrangement With several brackets Fastening clip for quick mounting Tests / Admissions Gas appliance directive DVGW certifcation Low voltage directive Weight Without accessories Packaging Multiple packaging in cardboard 90/396/EWG CE-0085AP /95/EC ~ 60 g 300 pieces 1200 pieces Adjustable switching differences Switching difference adjustment only inside shaded area: Pa Pa Example: Upper switching point 220 pascal. Switching difference between 14 and 36 pascal. Example: Upper switching point 40 pascal. Switching difference between 9 and 30 pascal. Example: Upper switching point 20 pascal, smallest switching difference 8 pascal. Switching point above (Pa) Switching point above (Pa) Swtching difference (Pa) Switching difference (Pa) 1) Higher pressures on request 2) Higher temperatures on request 3) Switching differential is factory-set 4) Fiberglass reinforced plastic 10% GF 5) According to DIN /5 Huba Control type Technical data subject to change - Edition 02/2012
3 Dimensions in mm / Electrical connections 1 Feeder (COM) 2 NC contact 3 NO Contact Cover with / without sealing and PT screw Contact safety guard with PT srew Cable exit AMP1 or AMP2 Tolerance of switching point The principle of high contact pressure Simplified representation of the new DPS 605 contact system. The high contact pressure results form the optimized length ratios of LC and LD. CP = DP ( LC LD ) Contact pressure (CP) Diaphragm pressure (DP) Pivot point Switching point upwards LC LC = Length of contact lever LM = Length of diaphragm lever LD Huba Control type Technical data subject to change - Edition 02/2012 3/5
4 Accessories Order number Cover with seal and PT screw Cover without seal and PT screw Cover with PT screw and cable output AMP (PT screw) Cover with PT screw and cable output AMP-2 Fastening clip Thickness of sheet metal mm Thickness of sheet metal mm Fastening clip (with mounting holes) Bracket type A Bracket type B Calibration certificate (PT screw) supplied loose Fastening clip (Dimensions in mounted state) Fastening clip Bracket type A Bracket type B Mounting plate Attachment small Attachment large For screw PT40 For screw PT40 Thickness of sheet metal 0.8mm Nominal loading limits for AC for DC U (V) 1 = ohmic 2 = inductive (cosφ 0.7) U (V) 1 = ohmic 2 = inductive Can also be operated with TTL-load 4/5 Huba Control type Technical data subject to change - Edition 02/2012
5 Headquarters Industriestrasse Würenlos Telefon +41 (0) Telefax +41 (0) Niederlassung Deutschland Schlattgrabenstrasse Walddorfhäslach Telefon +49 (0) Telefax +49 (0) Huba Control SA Succursale France Rue Lavoisier Technopôle Forbach-Sud Forbach Cedex Téléphone +33 (0) Télécopieur +33 (0) Vestiging Nederland Hamseweg 20A 3828 AD Hoogland Telefoon +31 (0) Telefax +31 (0) Branch Office United Kingdom Unit 13 Berkshire House County Park Business Centre Shrivenham Road Swindon - Wiltshire SN1 2NR Phone +44 (0) Fax +44 (0) [email protected]
Relative and absolute pressure switch type 529
Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20
Relative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
OEM Flow sensor type 200 for liquid media
OEM Flow sensor type 200 for liquid media Flow range 0.5... 150 l/min Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25 Temperature measurement -40... +125 ÀC The flow sensor Type 200 is based on the arman
Flow sensor type 210 for liquid media
Flow sensor type 0 for liquid media Flow range 0.... 0 l/min Nominal diameters DN 6 / 8 / 0 / / 0 / Temperature measurement -0... + ÀC The flow sensor type 0 is based on the ármán vortex trail principle.
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.
ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
COOL Shelf Quick Connect
Refrigeration equipment Shelf lighting High efficiency COOL QCS Quick-Connection-System Dimmable Various lengths Neutral White Warm White Pasta & Cheese Fresh Meat Packed Meat 1 A COOL Shelf Quick Connect
FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat
FREEZE Freezer equipment Canopy lighting High efficiency QCS Quick-Connection-System Dimmable Various lengths Daylight Neutral White Fresh Meat Packed Meat 1 A FREEZE Canopy PRODUCT DESCRIPTION 19.8 mm
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Test equipment for temperature and its reduction
Data sheet 90.2721 Page 1/6 Test equipment for temperature and its reduction Pt100 precision RTD temperature probe Calibrated temperature measuring chain with precision display device Calibrations as service
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design
.8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
MPLM1630 MPLM2535 MPLM3240
MPLM Self-centering 2-jaw electric parallel gripper with long stroke Plug & play user friendly gripper. No electricity consumption when gripper is engaged. No programming required. Gripper retention guaranteed
Instruction Manual Differential Pressure Transmitter
DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
SERIES 1800 - SINGLE POLE AND DOUBLE POLE ROCKER SWITCHES UP TO 12 (4) A 250 V~ AND 8 (8) A 250 V~
SERIES 1800 - SINGLE POLE AND DOUBLE POLE ROCKER SWITCHES UP TO 12 (4) A 250 V~ AND 8 (8) A 250 V~ PRODUCT ADVANTAGES Switching principle with long life endurance due to a low friction contact system (ball),
Pressure switches for gas and air Pressure sensors
Pressure switches for gas and air Pressure sensors line overview.0 Printed in Germany Rösler Druck Edition 08.00 Nr. 28 373 Page Karl Dungs GmbH & Co. - The pressure switch specialists For decades we have
type V46, solenoid or pneumatic operated
SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
MPPM1606 MPPM2508 MPPM3210
MPPM 2-jaw parallel self-centering electric gripper Plug & play user friendly gripper. No electricity consumption when gripper is engaged. No programming required. Gripper retention guaranteed in event
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
New XUY roller sensors
Do you want to simplify the sensor integration in your conveyor systems? New XUY roller sensors for packet, boxes, letters on roller conveyors. Telemecanique Sensor s OsiSense TM XUY photoelectric sensors
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
SMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Operating Instructions. Room temperature controller
Operating Instructions 1. Area of application The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc. Safety instructions
Solenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.
H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description
Data Sheet Series Load Cell Note: Not available in U.S. Features 0.5 t to 5 t (2 kn to 50 kn) Approved for use in calibrated weighing systems High accuracy (C1, C3 or 0.1 and 0.05) Hermetically-sealed
Reaction Torque Sensor
Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.
RESOL DeltaSol A. Mounting Connection Operation Examples. Manual
RESOL DeltaSol A Mounting Connection Operation Examples www.resol.dedeltasol A Manual Thanks for buying a RESOL controller. Read this manual carefully to get the best performance from this unit. Contents
CONFIGURABLE SAFETY RELAYS
MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
How To Use A Corona Mdi 110
CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output
Product Catalogue. AP Automatyka +48 67 357 10 80 [email protected] www.apautomatyka.pl ISO 16949 ISO 14001 OHSAS 18001 ISO 9001.
Product Catalogue ISO 16949 ISO 14001 OHSAS 18001 ISO 9001 Marine Division Since 1945 your qualified partner 1945 Huba Control AG founded 1974 Taken over by Stäfa Control System AG 1990 Concentration
Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
50 W Power Resistor, Thick Film Technology, TO-220
50 W Power Resistor, Thick Film Technology, TO-220 FEATURES 50 W at 25 C heatsink mounted Adjusted by sand trimming Leaded or surface mount versions High power to size ratio Non inductive element Material
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
T7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment
B MOTORPORT COMPONENT B TEMPERATURE ENOR Purpose and unction Temperature sensors used in modern engine management systems are of NTC [negative temperature co-efficient] design. imply as temperature rises
Actuator for modulating control AME 435
Data sheet Actuator for modulating control AME 435 Description The actuator automatically adapts its stroke to the valve end positions which reduces commissioning time (self stroking). The advanced design
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
Introduction. Refrigerant Leak Detecting System. Feature and Benefits
PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
MULTIFUNCTION TIME RELAY CRM-93H
4 MULTIFUNCTION TIME RELAY CRM-93H - 10 functions Features: Universal supply voltage AC/DC 12-240V 10 functions: - 5 time functions controlled by supply voltage - 4 time functions controlled by control
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
Power Resistor for Mounting onto a Heatsink Thick Film Technology
DIMENSIONS in millimeters Power Resistor for Mounting onto a Heatsink Thick Film Technology FEATURES 800 W at 85 C bottom case temperature Wide resistance range: 0.3 to 900 k E24 series Non inductive Easy
Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
SQUARE D INDUSTRIAL CONTROL PRODUCTS
SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and
Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16, 5, 40*) AFQM, AFQM 6 - return and flow mounting Description AFQM 6 DN 40, 50 AFQM DN 65-15 AFQM DN 150-50 AFQM(6) is a self-acting flow
DS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
Knob Potentiometer FEATURES. P16NP P16NM Panel Cutout. Thickness nut 2 mm washer 1.5 mm. Panel sealing ring 12 wrench Thread M10 x 0.75 10.2 9.
Knob Potentiometer P6, PA6 FEATURES Test according to CECC 4000 or IEC 60393- P6 - Version for professional and industrial applications (cermet) W at 40 C PA6 - Version for professional audio applications
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
CONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
Portable digital microprocessor thermometers with interchangeable probes
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Medium voltage arc flash eliminator units VAM 3ED,
Medium voltage arc flash eliminator units VAM 3ED,, Medium voltage arc flash eliminator units Medium voltage arc flash eliminator units The new innovative arc eliminator VAM 3ED is an extremely fast acting
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
Pressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
Knob Potentiometer with Switch
Knob Potentiometer with Switch The is a revolutionary concept in panel mounted potentiometers. This unique design consists of a knob driving and incorporating a cermet potentiometer. Only the mounting
Pluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules
CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN
Optical Power Meter. Specification & User Manual
Optical Power Meter Specification & User Manual Page 1 of 9 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology
Tilt switches MEMS technology, one or two axis N3 / N4... + long lifetime and highly reliability due to mechanism-free MEMS technology + combinable output signals + one or two axis measurement + tilt range
KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184
EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49
Control- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
Directory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals