Title Specification - Solderless Terminals - Cable Lugs for Signalling Applications. Reference Number SPS 33 - (RIC Standard: SC SP)

Similar documents
AMP Standard Terminals and Splices. RoHS. Ready

5.2. Overview. The better method to install solderless compression connectors on power cable

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

ISO VIEW OF AX SERIES XLR CABLE CONNECTOR

PIDG FASTON Receptacles and Tabs

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

COAXICON Contacts. RF Coax Connectors. Product Facts

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

Termination solutions Easily and reliably connect your wires

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

5SV Residual Current Protective Devices

Universal MATE-N-LOK Connectors

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

SMA Connectors. RF Coax Connectors. Product Facts

ODU MEDI-SNAP. Miniature Circular Connectors with Push-Pull Locking Made of Plastic or Metal.

Standard Buccaneer - Ethernet

AMPSEAL* Automotive Plug Connector and Header Assembly

UGVCL/SP/591/11KV HT AB CABLE

ULTIMATE SNAP-N-SEAL

I-PEX MHF4 Micro Coaxial Connector

CONFLEX ELECTRIC CABLE

7000 Series Buccaneer

Compliant Terminal Technology Summary Test Report

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Power cable compression lugs Installation of solderless compression lugs on power cables

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS

C ole s quality Open Frame Instrument Rotary Switch provides low

TBM5, TBM5-S and TBM5-SV

Givare NC-SRS 280 och 880

MCR1900 Media Converter 19-Slot Chassis

ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION

<< Previous Page Next Page >>

STANDARD MICRO-D CONNECTORS

Electrical Safety Products

ZS25 Screw Clamp Terminal Blocks Feed-through

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

50 W Power Resistor, Thick Film Technology, TO-220

SMD Power Elements Design Guide. 50 A SMD Technology Small Size High Current

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

Operating Instructions

ATL Fuel Level Sender Probes

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

Gulf Cable & Electrical Ind. Co.

High-ohmic/high-voltage resistors

High-ohmic/high-voltage resistors

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

ENGINEERING COMMITTEE

400 Series - Mini USB Buccaneer

Standards Affecting a Premise T-1 Installation

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Electronic overload relay EF65, EF96 and EF146

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

Universal Vehicle Power Supply 9007AX01. Installation Instructions

Electrical Practices for Construction Work

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

Electronic overload relay EF19 and EF45

HARTING Ethernet Cabling 4-poles Overview

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Vario-Series Accessories

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

WW12X, WW08X, WW06X, WW04X ±1%, ±5% Thick Film Low ohm chip resistors

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

How To Read A Pipe From A Sensor

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

By Jim Dunbar Product Manager, Terminals & Splices and Tom Michielutti, Senior Product Engineer, Tyco Electronics, Harrisburg, PA

RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)

Communication, Signal & Data Cables

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

VOLTS - Copper conductor PVC insulated SSA 1320, IEC & BS 6004 HO 7V - U With Solid Conductor - TYPE IEC 01. Insulation Thickness

TC Grounding and Bonding for Telecommunications Systems

Instruction Manual. Cable Splicing. Models , HDF1, HDF SS1

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Mini USB and USB 2.0-IP67 Connector System

I N D U S T R I A L C A B L E G L A N D S

EPIC CIRCON M23 Series Circular Signal Connectors

Power Resistor Thick Film Technology

FAQs-Main switchboard design criteria

Lightning Arresters P KVA P KVA. Description & Installation

Mounting Instructions for SP4 Power Modules

COATING & WRAPPING OF UNDERGROUND PIPING

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS

Cables and Accessories Selection Guide

400 Series Buccaneer BUCCANEER POWER. bulgin

AMP. 5.0 mm Power Key Connectors (5.0 PKC) (Wire-to-Board) Soft Shell Pin and Socket Connectors. Product Facts. Standard Density

Festoon 715 P PUR cable for flexible application in festoon systems

Transcription:

Discipline Engineering Standard - NSW Category Signalling Title Specification - Solderless Terminals - Cable Lugs for Signalling Applications Reference Number SPS 33 - (RIC Standard: SC 11 15 00 00 SP) Document Control Status Date Prepared Reviewed Endorsed Approved May 05 Standards and Systems Refer to Reference Number Standards Engineer H Olsen GM Infrastructure Strategy & Performance M Owens Safety Committee Refer to minutes of meeting 12/08/04

Disclaimer Australian Rail Track Corporation has used its best endeavors to ensure that the content, layout and text of this document is accurate, complete and suitable for its stated purpose. It makes no warranties, express or implied, that compliance with the contents of this document shall be sufficient to ensure safe systems of work or operation. Australian Rail Track Corporation will not be liable to pay compensation in respect of the content or subsequent use of this document for any other purpose than its stated purpose or for any purpose other than that for which it was prepared except where it can be shown to have acted in bad faith or there has been willful default. Document Approval The technical content of this document has been approved by the relevant ARTC engineering authority and has also been endorsed by the ARTC Safety Committee. Document Supply and Control The Primary Version of this document is the electronic version that is available and accessible on the Australian Rail Track Corporation Internet and Intranet website. It is the document user s sole responsibility to ensure that copies are checked for currency against the Primary Version prior to its use. Copyright The information in this document is Copyright protected. Apart from the reproduction without alteration of this document for personal use, non-profit purposes or for any fair dealing as permitted under the Copyright Act 1968, no part of this document may be reproduced, altered, stored or transmitted by any person without the prior written consent of ARTC. May 2005 Page 2 of 14

About This Standard This specification describes the general requirements for cable lugs of compression types, used in wiring signal equipment, to be manufactured and supplied to Australian Rail Track Corporation or contractors to Australian Rail Track Corporation. May 2005 Page 3 of 14

Document History Primary Source RIC Standard SC 11 15 00 00 SP Version 2.0 List of Amendments ISSUE DATE CLAUSE DESCRIPTION 1.1 14/03/2005 Disclaimer Minor editorial change 1.2 06/05/2005 All Document reformatted May 2005 Page 4 of 14

Contents 1. Introduction...6 2. Applicable Documents...6 2.1. Australian Standards...6 2.2. International Standards...6 3. Definitions...6 4. Environmental Conditions...7 5. Compliance with Specifications...7 5.1. General Requirement of AS 3100...7 5.2. Specific Requirements of this Specification...7 6. General Description...7 6.1. Non-insulated Cable Lugs...8 6.2. Insulated Cable Lugs...8 6.3. Bootlace ferrules...8 7. Technical Data - Terminals...8 8. Test Requirements...10 8.1. General...10 8.2. Temperature Rise...10 8.3. Current Overload...10 8.4. Resistance...11 8.5. Corrosion...11 8.6. Vibration...11 8.7. Tensile Strength...11 8.8. Dielectric Strength for Insulated Terminals...11 9. Identification and Marking...11 9.1. Colour code & preparation of wire for Pre-Insulated Cable Lugs...11 9.2. Colour code for Bootlace Ferrules...12 10. Information Required...12 11. Crimping Tools...12 11.1. Compaction ratio...12 11.2. Crimping Tools for Bootlace ferrules...13 12. Packaging & Documentation required with/before delivery...13 13. Check-list for inspection for the acceptance of cable lugs...13 14. Acceptance Testing of terminal lugs...14 May 2005 Page 5 of 14

1. Introduction This specification describes the general requirements for cable lugs of compression types, used in wiring signal equipment, to be manufactured and supplied to Australian Rail Track Corporation or contractors to Australian Rail Track Corporation. This sets forth the general requirements for the solderless type terminals for wire sizes from 0.5 sqmm to 300 sqmm cross sectional area. These terminatals may serve to connect flexible stranded, or solid conductors of copper, nickel, or other corrosion-resistant materials. This Specification is applicable to terminal lugs of insulated type, non-insulated type and to boot lace ferrules. 2. Applicable Documents 2.1. Australian Standards This Specification refers to the following Australian Standards: AS 1099 2.6-1988 Basic environmental testing procedures for electrotechnology-tests:fc-vibration (sinusoidal)} AS 1099.2Ka-1978 Basic environmental testing procedures for electrotechnology-tests-salt mist) AS 1125 AS 1199-1988 AS 3000 AS 3100 AS 3169 Conductors in Insulated Electric Cables and Flexible Cords (including Conductors, Insulation and Sheath ). Sampling procedures and tables for inspection by attributes SAA Wiring Rules. Approval and test specification-general requirements for electrical equipment Approval and Test Specification - Flat, Quick Connect Terminations. 2.2. International Standards This Specification refers to the following International Standards: BS 442 BS 4579 Electrical Terminals - Railway Signalling Apparatus. Specification for the Performance of Compression Joints in Electric Cable and Wire Connectors. 3. Definitions For the purpose of this specification, the following definitions shall apply :- Vital Circuits Circuits directly involved in ensuring the safety of the signalling system. May 2005 Page 6 of 14

Non-Vital Circuits Circuits involved in the control and indication of the signalling system, but not directly connected with the safety functions. 4. Environmental Conditions Temperature: -10 C to 85 C, unless otherwise specified Humidity: Relative Humidity 0 to 95% Exposure to atmospheric conditions such as; dust, dirt, oil, chemicals, rain, uv radiation, immersion in water, etc., as applicable for lugs used in outdoor applications (on railway tracks). 5. Compliance with Specifications 5.1. General Requirement of AS 3100 This Specification shall be read in conjunction with AS 3100 (Approval & test specificationgeneral requirements for electrical equipment), and the appropriate provisions of AS 3100 shall apply to the construction of the terminals and the insulation and/or safeguarding of parts which normally carry current. 5.2. Specific Requirements of this Specification A cable lug shall be deemed to comply with this Specification only if it complies with all the requirements of this Specification and passes the relevant tests specified herein. 6. General Description Cable Lugs shall be supplied of the 3 essential types such as: Non-insulated type including bimetal lugs Insulated type Bootlace ferrules Terminal/cable lugs shall be capable of being applied to the conductor with tools recommended by manufacturer, to provide mechanical security and electrical performance, as required. Crimping tool must provide for full crimping cycle before permitting the crimping jaws to return to the original open position. The current carrying portions of terminals shall be of copper or suitable copper alloy to meet prescribed tests. Cable lugs used for signalling applications shall be in accordance with signals standard drawings (M08-580/1) to (M08-580/11), attached to this specification in terms of dimensions, material, and specific applications, etc. Reasonable length of barrel shall be provided on the lug for crimping process. This compression process shall provide satisfactory electrical contacts and tensile strength as specified in Appendix A: Acceptance testing of terminal lugs. The current carrying portions of terminals shall be of Copper or suitable Copper alloy, as specified under technical data and shall compile with prescribed tests as laid down May 2005 Page 7 of 14

under test requirements. All conducting materials shall be coated with tin, nickel, or silver plating or equivalent, to prevent corrosion. Cadmium and zinc shall not be used. Coating shall be of quality and thickness to withstand tests specified in Section 8 (test requirements), without exposing the base metal. 6.1. Non-insulated Cable Lugs All non-insulated cable lugs shall be in accordance with the technical-general data, and drawings supplied, as specified 6.2. Insulated Cable Lugs All terminals/cable lugs of the insulated type shall have the outer surface of the wire barrel covered with insulation. The insulation shall extend over the wire barrel to a point not more than 5mm from the assembly of binding post (terminal mount), nut and washer for cable lugs on stranded wire/cable of 0.5 sqmm to 4 sqmm cross sectional area and not more than 11 mm on stranded wire/cable of 4 sqmm to 14 sqmm cross sectional area. The insulation shall not foul the assembly and shall extend a sufficient distance beyond the barrel and over the conductor insulation to meet the prescribed tests. The conductor insulation shall be supported and gripped where practicable along the wire barrel shaft to prevent the insulation slipping or being removed in either the crimped or uncrimped state. In addition the lug shall be of the double gripped type, which incorporates a separate inner conductive sleeve to grip and support the insulation. This sleeve is provided between the insulation and wire barrel without protruding past the barrel and hindering the terminal mounting arrangement. Insulation shall be of a quality and thickness to withstand prescribed tests and shall remain in the crimped position when exposed to a temperature of 85C. The insulation material shall be non-corrosive, resistant to abrasion and fungi, shall not support combustion, and shall be capable of being crimped at temperatures of 0C to 50C without altering its characteristics. 6.3. Bootlace ferrules Thin sheet Copper sleeve fitted with an insulated cone to assist entry of wire strands, and provide some support to the shaped system. The insulation on the ferrules shall be colour coded to identify the proper cross sectional area of the wire size that it should be used with. The standard colour code adopted by ARTC is as specified under the section "identification and marking". Twin pre-insulated sleeves shall also be in accordance with this colour standard. Crimping tools used with bootlace ferrules shall form a flat square uniform rectangular cross sectional area. 7. Technical Data - Terminals Conductive Material (except Quick Connect Range) : Copper Tensile Strength 99.9% Pure 200MPa May 2005 Page 8 of 14

Ductile Rating 35% Final Metal State Oxygen Content Fully Annealed 50 p.p.m. max Conductive Material - Quick Connect Range : Brass 30% Zinc Copper 70% Tensile Strength Ductile Rating Final Metal State 580MPa 6% min. Annealed Electroplating : Material Tin Tin Content 99.9% Other Metals Plating Thickness Lead & Antimony 2.5 Microns General Electric Properties : Total Conductivity Total Resistivity 99.5% IACS 17.38 Micro Ohms / cubic mm Insulation (for insulated terminals) : Material Breakdown Voltage Insulation Resistance Working Voltage PVC - for all (except Nylon 6 or Nylon 66 - for FIQC) 3.5 KV (min) Above 100 Megaohms Up to 600 volts AC/DC Working Temperature: 0 C to 85 C Torque Recommendations: For Hardware being Metric 8.8 Tensile Grade Dia. Thread 3mm 4mm 5mm 6mm 8mm Torque 2 Nm 3 Nm 5 Nm 9 Nm 22 Nm May 2005 Page 9 of 14

10mm 12mm 44 Nm 77 Nm Nominal "Pull Out" Force Wire Size Pull Out Force 0.5 mm2 8.2 Kg (80N) 0.75mm2 1.0mm2 1.5mm2 2.5mm2 4.0mm2 6.0mm2 12.2 Kg (120N) 16.3 Kg (160N) 20.4 Kg (200N) 25.5 Kg (250N) 35.7 Kg (350N) 51.0 Kg (500N) 8. Test Requirements Cable lugs shall meet the following requirements when attached to the conductor size for which they are designed and when crimped with the tools recommended by manufacturer: 8.1. General All tests shall be made at room temperature unless otherwise specified and the test area shall be free from drafts. Cable lugs under overload and temperature tests shall be securely bolted back to back and suspended in free air with a minimum clearance of 450 mm. Insulation supports, where provided, shall be closed on the conductor insulation for all the tests outlined herein after. 8.2. Temperature Rise Test currents, as specified in Appendix-A shall be conducted through the conductor and attached terminals continuously until the temperature is stabilized. The normal temperature rise shall not exceed 5C above that of the cable to which it is connected. Temperature rise shall be measured at the barrel of each terminal by means of a thermo-couple or other thermo-resistive devices. The temperature of the conductor shall be measured by thermo-couples or other thermo-resistive devices embedded in the conductor strands at a minimum distance of 900mm from the terminals and from the power source. 8.3. Current Overload Immediately following the temperature rise and with the temperature stabilized at the normal load current specified in Appendix-A, overload tests of 125 percent test current for two hours and 200 percent test current for five minutes shall be applied in this order and temperature rise measurements made at the conclusion of each period. The temperature rise shall not be more than 10C above that of the conductor to which it has been connected. May 2005 Page 10 of 14

8.4. Resistance The resistance of the conductor connection in the terminal/cable lug barrel shall be determined from the voltage drop measured between the intersection of the tongue and barrel of the connector and a point on the conductor 3 mm minimum from end of insulation support. The voltage drop shall not exceed the initial values specified in Appendix A. 8.5. Corrosion Terminal assemblies as used for resistance test shall be subjected to tests as specified in AS 1099.2Ka-1978 : ( Basic environmental testing procedures for electro-technology-tests-salt mist) 8.6. Vibration Tests shall be performed in accordance with AS 1099 2.6-1988 {Test Fc-vibration (sinusoidal) } 8.7. Tensile Strength The mechanical connection of the conductor and terminal shall not break when subjected to the tensile load specified in Appendix-A. Strain shall be applied at the rate of 12mm per minute. 8.8. Dielectric Strength for Insulated Terminals The terminal insulation shall be wrapped with a thin, conductive foil firmly pressed into and around the crimped surface of the barrel. The foil may extend back along the conductor insulation but shall be far enough away from the terminal tongue to prevent flashovers. A test voltage of 50 Hz shall be applied between the terminal tongue and the foil and shall be increased from 0 to 1,000 volts rms within 1/2 minute and maintained at that figure for a period of one minute. No breakdown of the insulation shall be evident within that time. Flashovers below the minimum dielectric strength shall be cause for retest but not rejection. 9. Identification and Marking Each cable lug shall be properly identified for conductor size range and manufacturer's identification and insulating sleeve shall be of the following colour for proper identification of conductor size range: 9.1. Colour code & preparation of wire for Pre-Insulated Cable Lugs Cross Section (mm 2 ) COLOUR of Insulated Terminals Strip Length inline splice Strip length 0.5-1.65 Red 4-5mm 7-8mm 1.0-2.60 Blue 5-6mm 7-8mm 2.5-6.00 Yellow 6-7mm 7-8mm May 2005 Page 11 of 14

9.2. Colour code for Bootlace Ferrules NOMINAL CROSS SECTION (mm2) AWG INSULATION COLOUR 0.25 24 Light Yellow 0.34 22 Light Green 0.50 20 White 0.75 18 Blue 1.00 18 Red 1.50 16 Black 2.50 14 Grey 4.00 12 Orange 6.00 10 Green 10.00 8 Brown 16.00 6 White 10. Information Required The manufacturer should provide all documentation necessary for identification and selection of proper lugs and ferrules based on the particular requirements, along with the application notes and suggestions, and tooling guide for using different types of lugs and ferrules. 11. Crimping Tools Standard "Utilux" or equivalent tools shall be used as specified for each cable terminations. The type of crimping tool shall be specified when supplying lugs other than the specified ones, in terms of dimensions, wall thickness, etc. Crimping tool shall be selected, so that when the cable is terminated with the appropriate die, the jaws of the die will close completely. A Go - Nogo gauge can be used to inspect the completed termination, in certain applications, to assess the result of the crimping. 11.1. Compaction ratio The nominated cable lug shall have sufficient wall thickness to provide proper compaction, when compression joint is formed. The figure for compaction shall be around 8%. To calculate the percentage reduction in cross sectional area the following formula shall be used. May 2005 Page 12 of 14

% reduction = ( La + Ca) - Da x 100 La + Ca Where, La = area in mm 2 of the annulus of the connector barrel Ca = area in mm 2 of the conductor Da = area in mm 2 of the hexagon compression die, when closed 11.2. Crimping Tools for Bootlace ferrules Crimping tool should possess a constant crimping pressure and ratchet release mechanism and should be able to crimp a range of ferrule sizes in one tool seat, using an automatic cross section detection system. The type of crimping tool shall be nominated. 12. Packaging & Documentation required with/before delivery The packaging shall be suitably packed to avoid mechanical damage to cable lugs. Unless otherwise specified, the information provided on the package shall be as follows: Item Description Supplier/manufacturer s Name or identification Quantity per package The standard of QA system may be specified, if applicable The following documentation shall be provided when supplying material to 13. Check-list for inspection for the acceptance of cable lugs Batch testing shall be performed. testing samples shall be selected in accordance with AS1199-1988 Visual inspection: Overall finish Electro-plating on the metal surfaces, insulation, etc, as applicable Physical dimensions: Whether dimensions of bore hole, palm hole, wall thickness, etc, are within reasonable tolerances. Physical strength: Compression jointing with the relevant cable, using the specified tool and die. Tensile strength of the made-up joint with the wire/cable Electrical tests: Resistance across the compression joint Non-conforming units or the complete supply shall be rejected and returned, May 2005 Page 13 of 14

depending on the discretion of the nominated person for quality inspection. 14. Acceptance Testing of terminal lugs (typical values, unless otherwise specified) Conductor Size TEST CURRENT (AMPERES) Maximum voltage drop(mv) millivolt drop of equivalent length of wire SQmm AWG INITIALLY AFTER TEST Tensile load Strength (min) Kg 0.50 22 9 1 3 6.8 0.75 20 11 1 3 8.6 1.00 18 16 1 3 17.3 1.38 1.50 16 22 1 3 22.7 2.50 14 32 1 3 31.8 4.00 12 41 1 3 50.0 6.00 10 55 1 3 68.2 10.00 8 73 1 3 102.3 16.00 6 101 1 3 136.4 50.00 1 3 200.94 95.00 1 3 391.3 120.0 1000 1 3 400 185 1000 1 3 400 195 2000 1 3 400 300 2000 1 3 400 Resistance across the compression joint shall be less than 15 micro-ohms when crimped, in all cases, unless otherwise specified. May 2005 Page 14 of 14