Solid State Relays Industrial, 1-Phase Analog Switching Type RM1E

Similar documents
Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Schematic Mechanical Drawing Derating Curve. Input. Output. Product Catalogue

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

MAXIMUM LOAD CURRENT 1 A SN SERIES

S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information

38 Series - Relay interface modules A

MT..KB SERIES 55 A 90 A 110 A THREE PHASE CONTROLLED BRIDGE. Power Modules. Features. Description. Major Ratings and Characteristics

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Safety technique. Emergency stop module BO 5988 safemaster

38 Series - Relay interface modules A

S101D01/S101D02 S201D01/S201D02

RY2 miniature industrial relays

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Inductive Proximity Sensors

MCR08B, MCR08M. Sensitive Gate Silicon Controlled Rectifiers. Reverse Blocking Thyristors. SCRs 0.8 AMPERES RMS 200 thru 600 VOLTS

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Solid-State Relays. Series Included. Solid-State Relays SIR SLR NLF PHS Series PHS...148

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Single Output Switching Power Supply

48 SERIES Relay interface modules 10 A

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

STPS5L60. Power Schottky rectifier. Description. Features

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Bulletin 150 SMC Flex Smart Motor Controller Specifications

BB800 Off-Grid Solar System

1 Form A Solid State Relay

PINNING - TO220AB PIN CONFIGURATION SYMBOL

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

AZ420 MINIATURE GENERAL PURPOSE RELAY

Electronic Control Devices The European Product Catalogue 2007

P6KE6.8A thru P6KE540A. TRANSZORB Transient Voltage Suppressors. Vishay General Semiconductor. FEATURES PRIMARY CHARACTERISTICS

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

49 Series - Relay interface modules A. Features

Redundancy Module QUINT-DIODE/40

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Thyristor/Diode Modules M## 501 MCC MCD MDC

Cross-beam scanning system to detect slim objects. 100 mm in

Modular I/O System Analog and Digital Interface Modules

Capacitive Prox E2K-X

Power Supplies 3. SDN-P DIN Rail Series

5STP 06T1600 Old part no. T 906C

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs)

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Relés e Contatores de Estado Sólido SIRIUS

How To Power A Schen

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MasterINTERFACE 39 Series - Relay interface modules

40 Series - Miniature PCB/Plug-in relays A. Features

1 Form A Solid State Relay

RM4TG20 three-phase network control relay RM4-T - range V

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

5STP 30T1800 Old part no. T 989C

Pluggable interface relays CR-P Pcb relays

Digital Expansion Modules Specifications

Adjustment functions for both span and shift have been incorporated

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Kit Watt Audio Amplifier

60 Series - General purpose relays 6-10 A. Features

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

DCS Input/Output Relay Card Series

5STP 21H4200 Old part no. TV

Installation and User Guide

IEC Connectors. Introduction

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

15 Series - Electronic step relay and dimmer. Features SERIE

80 Series - Modular timers 16 A. Features

Energy Management Energy Meter Type EM23 DIN

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

logic level for RCD/ GFI applications

Optocoupler, Phototransistor Output, with Base Connection

Digital input modules

UMEC International Corporation

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

MasterINTERFACE 39 Series - Relay interface modules

Application Note TMA Series

D.C. Motors. Products and specifications subject to change without notice.

Transcription:

Solid State Relays Industrial, 1-Phase Analog Switching Type RM1E RM1E..AA Product Description The analog switching relay works in accordance with the phase angle control principle, i.e., the output switching point in the AC sine wave depends on the control input which can be either 4-20mA or 0-10VDC. 4 ma or 0VDC correspond to Type Selection zero output power whilst 20 ma or 10VDC correspond to full output power (near linear power response). The relay switches off every time the output current crosses zero, and switches ON in accordance with the applied control input. Switching mode Rated operational Rated operational Control input voltage current E: Analog switching 23: 230 VACrms* 25: 25 AACrms AA: 4-20 madc 40: 400 VACrms 50: 50 AACrms V: 0-10VDC** 48: 480 VACrms 75: 75 AACrms 60: 600 VACrms 100: 100 AACrms * For nominal operational voltage of 110VACrms, use RM1E23... ** require an external supply voltage Selection Guide RM1E..V AC Solid State Relay Analog switching (phase-angle control) for resistive and slightly inductive load applications 4-20mA or 0-10V control input Rated operational current: 25, 50, 75 and 100 AACrms Rated operational voltage: Up to 600 VACrms Variable intensity LED-indication according to input current Integral snubber network Polarized lockable control connector for safe connection for voltage controlled version Ordering Key Solid State Relay Number of Poles Switching mode Rated operational voltage Control input Rated operational current Rated operational Blocking Control Rated operational current voltage voltage input 25 A 50 A 75A 100 A 230 VAC 650 V p 4-20 ma RM1E23AA25 RM1E23AA50 RM1E23AA100 0-10 VDC RM1E23V25 RM1E23V50 RM1E23V100 400 VAC 850 V p 4-20 ma RM1E40AA25 RM1E40AA50 RM1E40AA100 480 VAC 1200 V p 4-20 ma RM1E48AA25 RM1E48AA50 RM1E48AA75 RM1E48AA100 0-10 VDC RM1E48V25 RM1E48V50 RM1E48V100 600 VAC 1400 V p 4-20 ma RM1E60AA25 RM1E60AA50 RM1E60AA100 0-10 VDC RM1E60V25 RM1E60V50 RM1E60V100 General Specifications RM 1E 60 AA 50 RM 1E 23... RM 1E 40... RM 1E 48... RM 1E 60... Operational voltage range 90 to 280 VAC 340 to 460 VAC 200 to 550 VAC 410 to 660 VAC 90 to 265 VAC - 200 to 550 VAC 410 to 660 VAC Blocking voltage 650 V p 850 V p 1200 V p 1400 V p Operational frequency range 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz factor > 0.75 > 0.75 > 0.75 > 0.75 Approvals UL, cul, CSA* UL, cul, CSA* UL, cul, CSA* UL, cul, CSA* CE-marking Yes Yes Yes Yes** * Approvals pending for. ** Heatsink must be connected to ground for 600V types Specifications are subject to change without notice (14.01.2015) 1

Output Specifications RM1E...25 RM1E...50 RM1E...75 RM1E...100 Rated operational current AC51 Ta=25 C 25 AACrms 50 AACrms 75 AACrms 100 AACrms AC53a Ta=25 C 5 AACrms 15 AACrms 20 AACrms 20 AACrms Minimum operational current 150 ma 250 ma 400 ma 400 ma Rep. overload current t=1s 55 AACrms 125 AACrms 150 AACrms 150 AACrms Non-rep. surge current t=10ms 325 A p 600 A p 1150 A p 1150 A p Off-state leakage current < 3 ma < 3 ma < 3 ma < 3 ma I2t for fusing t= 10 ms 525 A2s 1800 A2s 6600 A2s 6600 A2s Critical dv/dt off-state min. 1000 V/µs 1000 V/µs 1000 V/µs 1000 V/µs Input Specifications Current controlled input Control current range (A1-A2) 4-20 madc Pick up current 4.2 madc Drop out current 4.1 madc Response time (input to output) 20 ms Voltage drop < 10 VDC @ 20 ma Dynamic impedance 330 Max. allowable input current 50 ma Reverse polarity protected Yes Voltage controlled input Supply voltage, Vss (A3-A2) 24 VDC ±20% Max. supply current 15 ma @ 19.2 VDC 20 ma @ 30 VDC Control voltage, Vcc (A1-A2) 0-10VDC Pick up voltage 0.2 VDC Drop out voltage 0.1VDC Control input current 0.15 ma @10 VDC Response time (input to output) 20 ms Supply reverse protected Yes Note: The use of twisted pair cable for the control input is recommended Housing Specifications Functional Diagram Weight 25 A, 50 A Approx. 60 g 75 A, 100 A Approx. 100 g Housing material Noryl, black Baseplate 25 A, 50 A Aluminium 75 A, 100 A Copper, nickel-plated Relay M5 1.5-2.0 Nm terminal M5 x 9mm 2.4 Nm Control terminal () M3 x 9mm 0.5 Nm Control terminal () 3 pin connector 0.64mm square pin with 2.54mm centre distance, tin plated brass Housing Nylon, UL94V-0 A2(-) A1(+) (Brown) (Black) (Blue) A3(+) A2(-) A1(+) IC IC IO IO 2 Specifications are subject to change without notice (14.01.2015)

Thermal Specifications Operating temperature -20 to +70 C (4 to +158 F) Storage temperature -20 to +100 C (-4 to +212 F) Junction temperature 125 C (257 F) Isolation Rated isolation voltage Input to output Output to case 4000 Vrms 4000 Vrms Heatsink Dimensions (load current versus ambient temperature) With the output fully ON (360 conduction angle) RM1E..25 RM1E..50 22.5 17.5 12.5 7.5 2.5 3.23 2.80 2.37 1.94 1.51 1.09 23 3.70 3.21 2.73 2.24 1.75 1.26 21 4.30 3.74 3.17 2.61 2.05 1.49 18 7 4.41 3.76 3.10 2.44 1.78 15 6.12 5.33 4.54 3.75 2.96 2.17 13 7.58 6.61 5.64 4.66 3.69 2.72 10 9.80 8.55 7.30 6.05 4.80 3.55 8 13.5 11.80 9 8.37 6.66 4.94 6-18.3 15.7 13.04 10.39 7.74 4 - - - - - 7 2 4 3 1.25 1.07 0.88 0.70 0.52 0.34 55 1.46 1.25 1.04 0.84 0.63 0.42 48 1.73 1.49 1.25 1.01 0.77 0.52 41 2.08 1.80 1.51 1.23 0.94 0.66 35 2.56 2.22 1.87 1.53 1.18 0.84 29 3.24 2.81 2.38 1.95 1.52 1.09 23 4.26 3.71 3.15 2.59 2.03 1.47 18 5.99 5.22 4.45 3.67 2.90 2.12 13 9.49 8.27 7.06 5.85 4.64 3.43 8-17.5 12.4 9.91 7.39 4 RM1.60..50 RM1E...75 0.99 0.81 0.63 0.44 0.26 0.08 55 7 1.00 0.88 0.75 0.63 0.50 0.38 80 4 1.28 1.07 0.86 0.65 0.44 0.23 48 67.5 1.15 1.00 0.86 0.72 0.57 0.43 70 1.64 1.40 1.15 0.91 0.67 0.42 41 60.0 1.33 1.16 1.00 0.83 0.66 0.50 60 3 2.11 1.82 1.54 1.25 0.96 0.67 35 52.5 1.56 1.37 1.17 0.98 0.78 0.59 51 2.60 2.25 1.90 1.55 1.20 0.85 29 4 1.88 1.65 1.41 1.18 0.94 0.71 43 3.30 2.86 2.43 1.99 1.55 1.11 23 37.5 2.33 2.04 1.75 1.46 1.17 0.87 34 4.36 3.79 3.22 2.65 2.08 1.51 18 3.01 2.64 2.26 1.88 1.51 1.13 27 6.1 5.4 4.6 3.77 2.97 2.18 13 22.5 4.16 3.64 3.12 2.60 2.08 1.56 19 9.76 8.52 7.3 6.0 4.8 3.54 8 -- -- 15.47 12.85 10.24 7.6 4 7.5 6.46 5.66 4.85 4.04 3.23 2.42 12 13.42 11.74 6 8.39 6.71 3 6 Specifications are subject to change without notice (14.01.2015) 3

Heatsink Dimensions (load current versus ambient temperature) - Cont... RM1E..100 Belastningsstrøm [A] Termisk modstand Effekttab [W] 100.0 90.0 80.0 70.0 60.0 0.60 0.52 0.43 0.34 0.26 0.17 117 0.74 0.64 0.54 0.44 0.34 0.24 101 0.91 0.79 0.68 0.56 0.45 0.33 87 1.09 0.96 0.82 0.68 0.55 0.41 73 1.33 1.16 1.00 0.83 0.66 0.50 60 1.66 1.45 1.24 1.04 0.83 0.62 48 2.16 1.89 1.62 1.35 1.08 0.81 37 3.01 2.64 2.26 1.88 1.51 1.13 27 4.73 4.14 3.55 2.96 2.37 1.78 17 9.94 8.70 7.45 6.21 4.97 3.73 8 Omgivende temp. [ C] Dimensions 44.8 28.9 29.6 12.3 2 x M5 APPLY HEATSINK COMPOUND 58.2 47.5 LED 1.84 Pitch 2.54 APPLY HEATSINK COMPOUND All dimensions in mm RM1E..AA 5.2 RM1E..V 4 Specifications are subject to change without notice (14.01.2015)

Applications I in A2 4 to 20 ma U line (Black) 0 V (Blue) 0-10 VDC (Brown) +24 VDC A2 (GRD) A1 (Vcc) A3 (V ss ) U line A1 Transfer Characteristics Output power as a function of control input Control current (ma) Control voltage (VDC) Output power 4 0 0 8 2.5 25 12 5 50 16 7.5 75 20 10 99 Heatsink Selection This relay is suitable for control of heaters, lighting and slightly inductive loads such as small fans. The relay can also be used for soft turn-on of high-power incandescent lamps. Ribbon Cable Selection Carlo Gavazzi Heatsink (see Accessories) Thermal resistance.....for power dissipation No heatsink required RHS 300 RHS 100 RHS 45C RHS 45B RHS 90A RHS 45C plus fan RHS 45Bplus fan RHS 112A RHS 301 RHS 90A plus fan RHS 112A plus fan RHS 301 plus fan Consult your distributor Infinite heatsink - No solution ---- 0 K/W 3.00 K/W 2.70 K/W 2.00 K/W 1.35 K/W 1.25 K/W 1.20 K/W 1.10 K/W 0.80 K/W 0.45 K/W 0.40 K/W 0.25 K/W <0.25 K/W ---- K/W > 25 W > 55 W > 60 W > 60 W > 100 W > 80 W Note: For power dissipation values smaller than those shown above, please refer to the corresponding heatsink curve in the SSR Accessories Section is referred to. R-System Cable sense 3-wire Cable length in cm 1 connector mounted RCS 3-100-1 Specifications are subject to change without notice (14.01.2015) 5