Hot water generation. Steam to liquid Building heat & domestic (double wall)

Similar documents
Maxi-Therm. Since 2002, throughout North America, Maxi-Therm has been manufacturing innovative packaged solutions for informed specifiers.

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Steam System Best Practices Condensate System Piping

Steam System Efficiency. Bill Lumsden Leidos Engineering

FLASH TANK ECONOMIZER PRODUCT GUIDE

Commercial Semi-Instantaneous Water Heaters

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

In-Line Air Separators

Heating Water by Direct Steam Injection

Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

REGULATING VALVE APPLICATIONS

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

How To Understand Evaporator

IGEMA BOILER LEVEL & TDS CONTROLS

Steam System Design and Best Practices Related to Kiln Drying

Element D Services Plumbing

C. starting positive displacement pumps with the discharge valve closed.

Boiler & Pressure Vessel Inspection discrepancies and failures

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves

Energy Efficiency in Steam Systems

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Standard Hydraulic Piping Flushing Procedure

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

APPENDIX E: CAPITAL NEEDS SUMMARY

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Oil and Coolant Circulating Heating System. Model - OCSM

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

Float and Thermostatic Traps Series H, C and X

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Chicago Stationary Engineer Licensure Examination Information

Steam Coil Installation, Operation and Maintenance

HOT WATER SYSTEMS CONTENTS

Facility Operations Physical Safety Guidance Document

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

Desuperheater Online Program Sizing Guidance

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

FILLING AND PURGING THE SYSTEM

Steam Generation Efficiency Module Blowdown Losses Section

How To Clean Water From An Ammonia Refrigeration System

PLBG/GAS SAFETY Information Bulletin

steam centre of excellence Steam Boiler System Optimization

Indirect-fired Steam & Boiler Water Heaters

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

HS-901(A) BASIC STEAM HEATING SYSTEMS

Forgotten savings: Heat recovery from surface blowdown

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Enclosed Football Stadium Design History and Lessons Learned

Condensing Boiler Efficiency

BOILER FEED AND CONDENSATE RECOVERY SYSTEMS Extend the life and efficiency of your boiler system

Factory owners must ensure the boiler is:

SULFUR RECOVERY UNIT. Thermal Oxidizer

CHAPTER 9: WATER HEATING

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

ASME Packaged Indirect Fired Water Heater

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Technical Data Manual Model Nos. and pricing: see Price List

Defining Quality. Building Comfort. Heating and Cooling Coils

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Printing and Publishing Energy Savings Guide

Refrigeration Basics 101. By: Eric Nelson

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

Condensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng

CGC s Hybrid System Loop Control

Mechanical Engineering Technician- Plant Technician

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

5.2. Vaporizers - Types and Usage

Best Practice in Boiler Water Treatment

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

OSHA Tank Venting DEFINITIONS

Backflow Bulletin #1

Air Conditioner Water Heater Model ACWH18

PBX Series Quick Fit Connector Bimetallic Steam Traps

Example. Fluid Power. Circuits

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

Why and How we Use Capacity Control

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

FLUID CIRCULATION PUMP PRESSURE

VAD. Variable Area Desuperheaters

Power Plants. BENSON Once-Through Heat Recovery Steam Generator. Power Generation

Energy Saving Fact Sheet Boilers

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

This section gives you some helpful information and tips on running your home and the equipment in it.

G234X-55 Conventional Gas Boiler

Select the Right Relief Valve - Part 1 Saeid Rahimi

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Transcription:

Building heat & domestic (double wall) 7

The Maxi-Therm concept We developed our patented, award-winning Vertical Flooded Heat Exchanger based on a proven system used in Europe for over 25 years but we innovated to enhance its performance. Like the European design, our Vertical Flooded Heat Exchanger features an oversized vertical shell & tube heat exchanger «A» that uses latent & sensible heat of steam to heat a liquid. Because it is oversized, the heat exchanger becomes flooded with condensate that is evacuated at a preset subcooled temperature (usually 200 F), making it possible to optimize use of the sensible heat of steam and eliminate the occurrence of flash steam. A condensate control valve «B» varies the level of condensate in the heat exchanger according to the process load «D & G» resulting in a 5.4% to 20% energy savings and reduction of greenhouse gas. 8 Maxi-Therm s patented innovations When developing our system, we identified two major issues with the European system: 1. The steam pressure must always be lower than the liquid pressure. 2. There is no guarantee of stability of the heated liquid outlet set point temperature, which results in a high level of wasted energy, thereby compromising cost-effectiveness. With Maxi-Therm s patented design, however, we resolved these issues 1. No pressure reducing station on the steam side «C» and no safety relief valve(s) to the roof are required. In fact, we recommend using high-pressure steam (even over 170 psig and we always size the heat exchanger to subcool condensate to 200 F «D». Plus, our heat exchanger uses more sensible heat, for greater performance and efficiency. Simply, our technology always uses ± 1000 btu/lb. of total heat of steam, either at 10 psig or 125 psig steam pressure. 2. We have achieved stability of heated liquid outlet set point temperature for building heat «H». In fact, we are the first to guarantee ± 2 F of set point temperature, even when variable speed drives are used on the circulating pump «G». 3. Stabilizing pump «J» pre-heats incoming liquid and creates additional turbulence in heat exchanger «A», averaging temperature towards sensor «K». Therefore the purpose of the stabilization circuit is to stabilize the fluid temperature across the heat exchanger circuit. 4. No condensate pumping substation needed to lift condensate «E». 5. Condensate Mixer «F» enables high pressure steam traps «I» to discharge directly in the flooded return line «E» without creating any water hammer. Online catalog maxi-therm.net

C 175 psig (378 F), 125 psig (353 F) 60 psig (308 F) or 10 psig (240 F) STEAM INLET E I I K 0% Flash condensate return Vertical heat exchange A J ± 2 F OF SET POINT H 9 G CUSTOMER CIRCULATING PUMP (BUILDING HEAT) F B D 200 O F condensate outlet (AT Full LOAD) 0% FLASH, 200 F CONDENSATE RETURN E CANADIAN PATENT # 2,416,353 US PATENT # 6,857,467 - B2 Honorable Mention by ASHRAE-AHR-Expo 2005 / Orlando, Florida First Prize For Product Design Technology 2002 A.Q.M.E. Canada. All major components are fabricated in the U.S.A

Conventional Control (1) (4) (3) (6) 10 (8) (4) (2) (5) (1) Less Make-up Water The boiler gets back more condensate so you use less fresh water. This also means less softening, chemical treatment, and surface blowdown. (2) Condensate Pumps Last Longer Condensate that is too hot causes pump cavitation and seal leaks. (3) No STEAM PRV STATION The Maxi-Therm can use high, medium or low pressure steam directly. (4) NO STEAM SAFETY RELIEF TO ROOF Many times the vent piping is the most expensive part of the entire system. Maxi-Therm can eliminate the need for both the pressure relief and condensate receiver vent. Online catalog maxi-therm.net

Maxi-Therm Control (1) (3) (4) (6) (10) 11 (7) (5) (6) (9) (2) (5) No PUMPING SUB-STATION The conventional heater will utilize a pump to push the condensate back to a central return station. The pump will require electricity or steam power, again using more energy. This power source will need a control system and isolation. (6) Smaller Steam Inlet And condensate return lines (7) Smaller CONTROL Valve (8) Vacuum Breaker The Maxi-Therm runs at constant pressure and a vacuum breaker is not needed. Independent site testing demonstrated seven times less corrosion rate. (9) 0% FLASH 5.4% to 20% ENERGY SAVING AND GREENHOUSE GAs REDUCTION (10) STABILITY OF SET POINT TEMPERATURE 2 F All major components are fabricated in the U.S.A

Sequence of operation Steam in the tubes at 100 psig STEAM 338 F STEAM 338 F TUBES 62% FLOODED TUBES 20% FLOODED 160 F 170 F CONDENSATE @ 200 F CONDENSATE @ 185 F 12 STEAM 338 F STEAM 338 F TUBES 92% FLOODED TUBES 100% FLOODED 178 F CONDENSATE @ 179 F NO CONDENSATE MC system operation example Temperature is controlled by modulating the condensate (MC) not throttling the steam. A building heat system with constant 100 psi steam at 338 F. At full load 20 F rise, water enters at 160 F and leaves at. As entering water temperature rises, the amount of surface exposed to steam is reduced. Condensate is cooled to 200 F or less by entering water, eliminating flash steam. 5.4% to 20% energy savings. No steam PRV station, no safety relief to roof, no pumping sub-station. Online catalog maxi-therm.net

Manufacturing facilities and service technicians in the United States & Canada Custom fabrication per ASME Section VIII DIV #1, U-UM-R stamp. Quality control assurance program CSA B51, ANSI B 31.1, B 31.3, B 31.5. National board ISO 9001-2000. Over 250 units installed from 10 usgpm to 2750 usgpm in HOSPITALS, UNIVERSITIES and institutions. 13 All major components are fabricated in the U.S.A

14 Online catalog maxi-therm.net

15 All major components are fabricated in the U.S.A