M98 HEPA Filter System Performance Study: Testing Methods and Criteria

Similar documents
HEPA Filters and Filter Testing A Comparison of Factory Tests and In-Service Tests Bulletin: PB

HEPA FILTER DEFECTS ARE COMMON

EACO DOP / PAO TESTING GUIDELINE 2013

HEPA Filters and Filter Testing A Comparison of Factory Tests and In-Service Tests

Environmental Monitoring

Air and Water Balancing - Sound and Vibration Testing - Cleanroom Services - Building Commissioning Building Envelope Testing Thermal Imaging

Certification system of air filter quality (CAF mark)

Testing HEPA/ULPA filters at the manufacturer s facility and in situ on the user s premises

Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested

MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard

HEPA Filters for Pharma Applications Cleanrooms & Safety Applications. Gordon Farquharson June 2012

In-Place HEPA Filter Penetration Test

ACC1-10, ACC1-25, ACC1-50, ACC1-125

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice

PROCEDURAL STANDARDS FOR CERTIFIED TESTING OF CLEANROOMS

HVAC Design Requirements

APPENDIX A-1 SAMPLE CLEANROOM SPECIFICATIONS MICROELECTRONICS & SEMICONDUCTORS

HEPA Filters For High Efficiency Applications IEST-RP-CC001.3 MIL-STD-282

Camfil Farr Technical Services Bulletin

ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS

PERFORMANCE QUALIFICATION OF A CLEAN ROOM FROM A QUALITY PERSPECTIVE

Viledon HEPA and ULPA Filters The Patented Solution for Sterile Air and Clean Rooms. Product Overview

cleanroom validation Cleanroom Validation

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

Laminar Flow Cabinets

RITTER Multiple Sonic Nozzle Calibration System

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

DRAFT 8/13/2015. Proposed Addition of Non-Mandatory Appendix FC-B has been withdrawn from publication in the next edition.

TR40 Sterilizing Filtration of Gases A comparison with TR26 Sterilizing Filtration of Liquids

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Class II, Type A2 Biological Safety Cabinet HEPA Filter Loading Capacity

MAC 10. Original & IQ FAMILY OF FAN FILTER UNITS

Particle motion, particle size, and aerodynamic diameter

Particle Counting and Environmental Monitoring In Pharmaceutical / Life Sciences

Improving Data Center Energy Efficiency Through Environmental Optimization

1. Certification: Employ an ASCS certified by NADCA on a full-time basis. 2. Supervisor Qualifications: Certified as an ASCS by NADCA.

A Basic Design Guide for Clean Room Applications

Trouble Shooting. Pump

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

OPTICAL PARTICLE SIZER MASS CALIBRATION METHOD

GUIDELINE FOR GAS TURBINE INLET AIR FILTRATION SYSTEMS

SPECIAL APPLICATIONS

Assembly and Installation Procedures

Duct Leakage Testing. Ken Helfers, TSI Inc. 2011, TSI Incorporated

Medical Air Systems: Scroll

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

HOSPITAL ISOLATION ROOM HVAC SYSTEM DESIGN

NEBB Cleanroom Performance Testing Certified Professional Seminar and Exams

Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2

Commercial Coil Cleaning:

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

Guidance on the use, testing and maintenance of laboratory and animal isolators for the containment of biological agents

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

ME 538: Experiment # 1 Flow measurement and particle generation instruments

Method 202 Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources. By: Paul Ottenstein

How To Install A Perfect 16 Id Series Filter System

Surface Scanning Probes for Lighthouse Particle Counters Solair Gen D/E

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Advantages Of A New And Advanced Nanofiber Coating Technology For Filtration Media Compared to The Electrospinning Process

SECTION HVAC AIR-DISTRIBUTION SYSTEM CLEANING

VSO MAX HP High Flow Proportional Valve

IEQ-15 Air Distribution System

Air Pollution Control Division. Technical Services Program

SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

DEEPSEALSM SERVICE SOLUTIONS

Particle testing in cleanroom high-pressure gas lines to ISO made easy with the MET ONE 3400 gas calibrations

SEPARATING DUST PARTICLES USING AN AERODYNAMIC DEDUSTER

HVAC Air Systems. Recirculation Air System Types

Residential Duct Systems for New and Retrofit Homes

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

This will also provide you with the knowledge to insure long life for your Investment

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Reliability of Air Moving Fans, and Their Impact on System Reliability. A White Paper from the Experts in Business-Critical Continuity TM

Clean air solutions for turbo machinery

Filter Media Technology Specially Formulated to Protect Gas Turbines, Compressors and Generators

Compressed Air Filters

Standard Hydraulic Piping Flushing Procedure

REAL-TIME DUST AND AEROSOL MONITORING

Laminar Flow Elements

ANSI/ASHRAE

PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE

TÜV RHEINLAND ENERGIE UND UMWELT GMBH

Filtration and Air-Cleaning Systems to Protect Building Environments from Airborne Chemical, Biological, or Radiological Attacks

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Cartridge Filter Application Notes

THE EFFECTS OF LAMINAR AIRFLOW IN SEMICONDUCTOR FABS ON THE VENTILATION DESIGN FOR EXHAUSTED ENCLOSURES

Roll-to-Roll Coating Operations in a Clean Room

Transcription:

M98 HEPA Filter System Performance Study: Testing Methods and Criteria Benjamin D. Green Mechanical Engineer Naval Surface Warfare Center Dahlgren Division Shipboard CBR Protection Branch benjamin.d.green@navy.mil 1

Agenda Overview of NSWCDD s Filter Performance Evaluation NSWCDD Particulate Leak Test Method Issues, Considerations and Actions Taken HEPA Filtration Overview Thermal vs. Laskin Nozzle Aerosol Generation Difference Between Leak and Efficiency Testing Threat and Filtration Criteria Recommendations and Continued Work 2

M98 Filter Performance Evaluation Task: Beginning in January 2004, NSWCDD examined the remaining filtration capacity of the M98 gas filter after 300, 500, and 700 days of service at a fixed-site location. Objective: Provide data and modeling information to accurately assess the performance of new and in-service fixed-site M98 filters. Testing: Aerosol leak tests were performed on each system before the old filters were removed and after the new filters were installed. 3

NSWCDD Leak Test Method Clean Air to Air Handling Unit Sample Lines Aerosol Inlet into Prefilter box Photometer FFA 1000-100 Aerosol Generator 4

Issues and Considerations Test Results: Lower than expected leak test results Possible Explanation of Results: Individual filter performance vs. overall system performance Environmental effects Gaskets Filter media Test equipment and procedures 5

Actions Taken Environmental Effects: Testing performed across a diverse range of environmental conditions, ruling out the possibility of humidity and temperature having an effect on the testing process. Gaskets: Gaskets were tested by two methods: Caulking to eliminate any error caused by gaskets. Metal to gasket seal to eliminate gasket to gasket error. Neither method had a noticeable effect on photometer reading. Test Method: Standardized test methods through research and following IEST and ASME standards. Test Equipment: Researched and determined the equipment needed for testing. 6

HEPA Filtration Curve 100.00 99.99 99.98 Efficiency (%) 99.97 99.96 99.95 99.94 99.93 MPPS 99.92 99.91 0.1 0.2 0.3 0.4 0.5 Particle Size (micrometers) Widely Known Facts: 1. Efficiency testing is conducted at 0.3 µm because it was thought to be the most penetrating particle size (MPPS). The actual MPPS is between 0.1 and 0.2 µm depending on the media. 2. Efficiencies at larger particle sizes (1.0-10 µm) are significantly higher. 7

Thermal vs. Laskin Nozzle Aerosol Generation Count Basis Measurement Method Mass Basis Measurement Method Laser Particle Counter Scanning Mobility Particle Sizer Photometer 8

Thermal vs. Laskin Nozzle Generator Leak Test Results Note: 1. Systems were tested on the same day with the same calibrated photometer. 9

COLPRO System: Leak Test vs. Efficiency Test Leak Test: Measure of the bypass leakage of a polydispersed aerosol through a filtration system at its rated airflow. Verifies that both the particulate filter gaskets and o-ring seals within a COLPRO system are free from leaks, as well as identifying any significant damage to the filters. Efficiency Test: Measure of the penetration of a specific size aerosol through a filtration system at its rated airflow. A quantifiable examination of not only the gaskets and orings, but also the installed filter s media. Characterizes the system performance against specific threat particle sizes. 10

Equipment Required for a System Efficiency Test Monodispersed aerosol: Challenging a filtration system with only particles of the desired challenge size. Insufficient output of aerosol will result in statistical uncertainty for larger systems (i.e. above 5,000 CFM). OR Specific particle size measurement: Measuring only the desired particle size of a polydispersed aerosol challenge. Equipment is costly (> $100K), non-ruggedized and contains a radiation source. 11

Topics Considered for Particulate Performance Threat: What is the threat particle size? What is the expected upstream concentration of particles? What is an allowable downstream concentration of particles? Type of testing required: Leak Efficiency M98 particulate filters media selection: HEPA ULPA 12

Recommendations and Continued Work Perform leak tests on all systems. Design one set of equipment capable of performing leak tests on all systems regardless of airflow. Develop the equipment needed to characterize a system s efficiency across a range of sizes. Standardizing test ports for all COLPRO applications. Study the threat as compared to current HEPA media efficiency to determine desired filtration criteria. 13

Questions? Ben Green NSWC Dahlgren Division benjamin.d.green@navy.mil 14