Particle Monitoring Requirements in Pharmaceutical Cleanrooms
|
|
|
- Charity Newton
- 9 years ago
- Views:
Transcription
1 Particle Monitoring Requirements in Pharmaceutical Cleanrooms All drugs must be manufactured in accordance with the current Good Manufacturing Practice (cgmp) regulations. Pharmaceutical manufacturers must demonstrate compliance with the regulations at every stage before a drug can be released to market. This paper explains the various microcontamination requirements of pharmaceutical manufacturing, defines a clean manufacturing environment, and shows how to prove contamination control over an environment. Why do I need a Particle Counter? All drugs must be manufactured in accordance with the current Good Manufacturing Practice (cgmp) regulations which state that cleanroom validation must be performed and impose limitations for production environments. In the United States these regulations are governed by the Food and Drug Administration (FDA) as the 21st Code of the Federal Regulations (CFR). In Europe, European Commission (EC) guidelines must be met. The pharmaceutical company manufacturing the product must, therefore, prove that they have been in compliance with the regulations at every stage before a drug can be released to market and ultimately the end user. The US cgmp regulations govern various drugs manufacture activities including Organization and Personnel [21 CFR 211 Subpart B] Buildings and Facilities [21 CFR 211 Subpart C] Production and Process Controls [21 CFR 211 Subpart F] A pharmaceutical company must have a quality control department that has the responsibility for drug approval independent of the production department. This department is responsible for the routine quality assurances that: Establishes documented evidence which provides a high degree of assurance that a specific process will consistently produce a product meeting its predetermined specifications and quality attributes. FDA definition in General Principles of Validation, May To satisfy the requirements, the products are manufactured in a controlled environment. Cleanrooms are employed to reduce the variability of potential production environments and as controlled environments can be regulated to meet specific standards. GMP regulations require that these environments be rigorously monitored to ensure that there is full and constant awareness of current environmental conditions, both for viable and non-viable contamination. Cleanrooms A cleanroom is the fundamental starting point for contamination control. In the old Federal Standard 209E, a cleanroom is defined as a room in which air filtration, air distribution, utilities, materials of construction, and equipment are maintained in a controlled manner. Operational procedures are defined and regulated for airborne particle concentrations to meet appropriate particulate cleanliness classifications. ISO is the international standard of defining cleanroom contamination levels. Pharmaceutical cleanrooms are classified according to the particle concentration of the air that is required to meet the cleanliness criteria for the manufacturing process being performed. Using the ISO standards, the higher the classification number, the lower the particle concentration. Originally cleanrooms were classified according the number of particles per cubic foot at 0.5 microns (µm). The determination of the cleanroom class is a process based on actual statistically valid measurements, as described in the following section. Page 1 of 7
2 Particle Count Room Classification There are three measurement phases involving particle counting in cleanrooms: As-Built: a completed room with all services connected and functional, but without production equipment or personnel within the facility. At Rest: all the services are connected, all the equipment is installed and operating to an agreed manner, but no personnel are present. Operational: all equipment is installed and is functioning to an agreed format, and a specified number of personnel are present, working to an agreed procedure. The airborne particle count test is performed by counting particles at defined grid locations within the as-built cleanroom. The test points should be equally spaced throughout the room and at work height to demonstrate the quality of the air cleanliness as it approaches the work area. Equipment location may result in modifications to the standard grid pattern. The number of measurements taken at each test point depends on the cleanroom class and the statistical requirements specified in the standards. The standards also state that the data should permit defining the classification level with 95% confidence level. It is recommended that a particle counter capable of 0.5 µm sensitivity be used for the definition of classes ISO Class 5. To calculate the minimum number of samples required: Area (m 2 ) 0.5 Minimum sample volume is determined by 20 x 1000 Class limit Total required sample time (minutes): Minimum volume x minimum mumber samples 28.3 Page 2 of 7
3 The following table shows the ISO cleanroom classifications. Pharmaceutical cleanrooms typically operate at Class 5 (most aseptic areas), Class 7 (surrounding areas), or Class 8 (support areas). Pharmaceutical Cleanroom Utilization We can prove that a cleanroom meets a standard using a particle counter. The room classification achieved also dictates which production activities can be performed in the cleanroom. A document produced by the FDA and published in 2004 defines two areas. A critical area is where the sterilized drug product, containers, and closures are exposed to environmental conditions that must be designed to maintain product sterility, and a supporting clean area is where nonsterile components, formulated products, in-process materials, equipment, and container/closures are prepared. The environmental requirements for these two areas are given in the FDA Guide as follows: Critical area: This area is defined as critical because it contains sterilized products that, if exposed, are vulnerable to contamination. To maintain product sterility, it is essential that the environment in which aseptic operations are conducted be controlled and maintained at an appropriate quality. One aspect of environmental quality is the particle content in the air. Particles are significant because they can enter a product as an extraneous contaminant and can also contaminate it biologically by acting as a vehicle for microorganisms. Page 3 of 7 Air in the immediate proximity of exposed sterilized containers/closures and filling/closing operations would be of appropriate particle quality when it has a per-cubic-meter particle count of no more than 3,520 in a size range of 0.5 µm and larger when counted at representative locations normally not more than 1 foot away from the work site, within the airflow, and during filling/closing operations. This level of air cleanliness is also known as Class 100 (ISO Class 5). (Guidelines on Sterile Drug Products Produced by Aseptic Processing, CDER, FDA 2004) Particle Measuring Systems recommends that measurements to confirm air cleanliness in critical areas be taken at sites where there is the most potential risk to the exposed sterilized product, containers, and closures. The particle counting probe should be placed in an orientation demonstrated to obtain a meaningful sample. Regular monitoring should be
4 performed during each production shift. We recommend conducting nonviable particle monitoring with a remote counting system. These systems are capable of collecting more comprehensive data and are generally less invasive than portable particle counters. HEPA-filtered air should be supplied in critical areas at the point-of-use. The air flow should be at a velocity sufficient to sweep particles away from the filling/closing area and maintain unidirectional airflow during operations. Supporting Clean areas: Classification of a supporting clean area is explained by the FDA as follows: The nature of the activities conducted in a supporting clean area determines its classification. It is recommended that the area immediately adjacent to the aseptic processing line meet, at a minimum, Class ISO 7 standards under dynamic (operational) conditions. Manufacturers can also classify this area as Class ISO 6 or maintain the entire aseptic filling room at Class ISO 5. An area classified at a Class ISO 8 air cleanliness level is appropriate for less critical activities (e.g., equipment cleaning). (Guidelines on Sterile Drug Products Produced by Aseptic Processing, CDER, FDA 2004) Environmental Monitoring To meet the required cgmp compliance, an area has to demonstrate that it meets the specifications required for drug manufacturing. A clean manufacturing environment needs to be rigorously monitored to ensure that there is full and constant awareness of current conditions, including the detection of periodic events which could be catastrophic if gone unnoticed. Constant monitoring creates a continuous flow of information, resulting in a large quantity of data which can be used to watch for trends. The manufacturing facility should therefore have a comprehensive environmental monitoring program, which includes monitoring for non-viable and viable airborne particulates, surface viable contamination and, in the aseptic areas, personnel [21 CFR ]. These procedures should address frequencies and locations for the monitoring sample points, warning and alarm limits for each area, and corrective actions which need to be undertaken if any of the areas show a deviation from expected results. Actions taken when limits are exceeded should include investigation into the source of the problem, the potential impact on the product, and any measures required to prevent a recurrence. In general, less frequent monitoring is required in areas of a lower classification (ISO Class 8 or unclassified rooms). This reduced frequency monitoring performed in "controlled" environments (ones with some level of particulate controls) should be of the same integrity as that sampled in the highest classification. During a quality or regulatory audit the specifications for viable and non-viable particulates will be reviewed. Focus is placed on the viable monitoring as this will potentially have the greatest impact on the final product. Rooms are, however, classified for both, with the levels of viable particulates being a function of the room classification, determined by non-viable monitoring. EC Based Cleanroom Classes Room classification Page 4 of 7 Maximum concentration limits (particles/m 3 of air) for particles / Airborne Viables (cfu/m 3 ) 0.5 µm 5.0 µm Viable cfu/m 3 And / 90 mm settle plate <1 <1 / 4 hrs <10 <5 / 4 hrs <100 <50 / 4 hrs <200 <100 / 4 hrs A Operational 3,500 1 B Operational 350, C Operational 3,500,000 20,000 D Operational Not defined Not Defined Manufacturers must determine that ISO Class 5 conditions have been validated and are maintained in areas where sterile product and components, including container/closure systems, are exposed; ensure that if limits are exceeded, an investigation is conducted and appropriate action is taken; and perform microbial identification, especially in aseptic areas, and watch for trends.
5 When a product is to be exported to Europe, it must comply with the EC guidance on room classification. The EC requires that a room be classified in accordance with the ISO test methodology but apply the limits as set out in Annex 1. To achieve this standard, a minimum of 1m 3 of sample must be taken per room; this is to satisfy the statistical confidence that the target of <1 at 5.0 µm has been achieved. Monitoring Particulate Levels in Cleanrooms After a room has been verified as meeting ISO for room particle levels and has established cleanliness suitable for product manufacture, it must be proven that the cleanroom can be maintained at that level. The cgmp guides from both the EU and the FDA define what levels of particulates are allowed for sterile manufacturing and how and when monitoring should take place. Portable Particle Counter A compact approach to maintaining cleanliness is to build data storage into a portable particle counter. The data can then be exported to a computer for statistical manipulation. However, there is an increasing need to monitor more locations, more regularly than can be easily achieved using a portable counter. This need is being driven by the desire to reduce operational costs, increase confidence in good manufacturing practices, and fulfill regulatory requirements. Facility Monitoring System One way of achieving the monitoring levels required is to install a Facility Monitoring System (FMS) which includes particle sensors. An FMS is either a single continuous particle counter installed into a critical location, or an arrangement of instruments linked to a central monitoring computer suitable for making the measurements required. The computer controls the intake of data from the particle counters, logs and displays the information, and reports to the operator any changes in conditions or trends. Inputs to the FMS may be from facility sources other than particle counters. This leads to a full, independent environmental monitoring system which can accept data from viable monitoring, differential pressure sensors, air velocity, and temperature/relative humidity sensors. An automated FMS will provide increased vigilance while decreasing the labor requirements to make measurements, manually transfer data to interpretive applications, and produce reports to support product release. ISO says that a Class 5 cleanroom with an installed continuous particle monitoring system can be revalidated every 24 months. However, if a continuous system is not in place, revalidation must occur every 6 months. If the system is well planned, fast detection of potential problems in operating conditions will occur enabling counter measures to be taken rapidly. Any significant trends in operating conditions over a long-term, can be monitored. Statistical analysis of data should allow for closer control and identification of normal and abnormal conditions. There are three basic approaches to obtaining automated particle counts: Manifold system (using multiple tubes via multi-port scanning) linked to a particle counter Individual particle sensors Combination of manifolds and particle sensors Manifold System This solution is very common and consists of a central manifold with up to 32 sample tubes radiating from a central manifold location. Each tube is capable of drawing a sample from up to 38 m from the manifold into a single particle counter. The data from each of the monitored sample points is reported back to a central monitoring software package. The software is a validated package, which reports the data to the users in multiple formats. These formats include realtime current values, spreadsheet viewing of historical data and live time plots. To report problems to field operators a system of local alarm devices, paging, and alerting of out of condition warnings and alarms is employed. Page 5 of 7
6 Advantages of a manifold system: Low cost per sample point. This system requires a particle counter, aerosol manifold, and a length of flexible tubing for each position monitored. Low maintenance and calibration costs; only a single particle counter per manifold to calibrate and service. Disadvantages of a manifold system: Only samples one location at a time, and transient events may be missed. To offset this, sample sequencing may be biased to monitor the most critical locations more often. Loss of particles of 5 µm and greater in the tubes may occur due to sedimentation and impaction. However, a properly designed system that maintains turbulent flow in the tubes to eliminate unnecessary valves and minimizes sharp bends. Individual Particle Sensors Increasingly, to ensure that continuous monitoring is preserved, dedicated, locally-mounted particle sensors are being used. A sensor consists of a small enclosure, housing an optical system, a light source (laser diode), and signal generation electronics. The sensors often require an external vacuum source and signal communication cable to transmit data to the central monitoring computer. Advantages of individual sensors: Automated, so lower personnel costs Continuous monitoring and reporting of data, therefore detecting short-lived particle bursts Simple, low-cost installation Ease of relocation to alternative positions; easy to rotate out for servicing Highest level of confidence Disadvantages of individual sensors: More instruments Higher initial equipment cost Higher maintenance cost Page 6 of 7
7 Combination System An alternative to the above choices (manifold or individual sensors) is a combination which uses the advantages of both systems. In this solution, the majority of sampling is monitored using the manifold system, while specific critical locations are continuously sampled by individual sensors. Special Considerations There are various applications that require monitoring as part of process control but have special considerations; two different applications are identified below: Sterilizing Tunnels These are typically classified as the first part of the aseptic environment, and therefore ISO Class 5. As a classified environment, it must be regularly monitored. One of the monitoring functions of a particle system is to gauge the presence of viable particles. In this case, the environment is sterile due to high temperatures; therefore the first potential for viable organisms to exist is within the cooling zone where temperatures drop to a point which may support viable organisms. If sampling of the hot zone must be performed, then the sample must be cooled to a sufficient temperature acceptable by the particle counter. This is typically less than 35ºC. The only method of cooling the sample down is to use a cooling probe. Lyophilization The process under which products are manufactured using lyophilization requires a standard aseptic manufacturing filling operation, sterilization of the vials, classic filling in either open or isolator fill lines and subsequent semistoppering of the final product. The environment where the freeze dryer is loaded needs to be a sterile area due to the non-closure of the final stopper prior to freeze drying; additional controls to prevent contamination should be in place. The stopper is placed on top of the vial and is ultimately seated in the Lyophilizer. As a result, the contents of the vial are subject to contamination until they are actually sealed. The required monitoring for critical areas should be continuous and within the zone immediately surrounding the product whenever the product or open container is exposed to the environment. The monitoring locations should therefore be as close as practically possible to the exposed product or semi-stoppered vials. Where a significant distance exists between the end of the filling line and semi-stoppering and the loading door of the lyophilizer, the product should be maintained within an ISO Class 5 environment and monitored at intervals throughout this distance. Summary: Particle monitoring is required to meet cgmp requirements. Cleanrooms must be validated to demonstrate a cleanroom classification and monitored to prove that product is not contaminated. The level of monitoring varies with the classification of the cleanroom dependant on the use of the area. Monitoring particulate levels in cleanrooms can be approached using several different methods; the best method depends on the function and classification of the cleanroom. Author: Mark Hallworth Mark Hallworth is the Pharmaceutical Manager for Particle Measuring Systems in Boulder, CO USA. He has managed the installation and validation of over 200 facility-monitoring projects for over 8 years and has managed the company transition to 21CFR part 11 compliant software. He currently lectures for pharmaceutical societies throughout Europe and the US on non-viable particulate monitoring, cgmp compliance (both for FDA and EU approval processes), and facility monitoring systems and the implications of validating those systems to GAMP. He can be contacted at [email protected]. March 2005 App 41 Page 7 of 7
EU GMP Annex 1 Update 2008: Airborne Particle Counting
EU GMP Annex 1 Update 2008: Airborne Particle Counting Airborne Particle Counting for Pharmaceutical Facilities: Update 2008, EU GMP Annex 1 Morgan Polen - VP of Applications Technology, Lighthouse Worldwide
GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS
PHARMACEUTICAL INSPECTION CONVENTION PHARMACEUTICAL INSPECTION CO-OPERATION SCHEME PI 032-2 8 January 2010 RECOMMENDATION GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE
Regulations Concerning
Regulations Concerning Airborne Particle Counting Two types of activities performed with an airborne particle counter: Classification focuses primarily on the environment Particle Counting Applications
TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS
TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS APPLICATION NOTE CC-105 (US) Introduction This application note will demonstrate how real-time viable particle count data will
CLASSIFICATION OF CLEANROOMS
CLASSIFICATION OF CLEANROOMS Cleanrooms are classified by the cleanliness of their air. The method most easily understood and most universally applied is the one suggested in the earlier versions (A to
Qualification of an Environmental Monitoring Program
[ Scott Sutton Qualification of an Environmental Monitoring Program Scott Sutton Microbiology Topics discusses various topics in microbiology of practical use in validation and compliance. We intend this
Particle Counting and Environmental Monitoring In Pharmaceutical / Life Sciences
Particle Counting and Environmental Monitoring In Pharmaceutical / Life Sciences LIGHTHOUSE WORLDWIDE SOLUTIONS WWW.GOLIGHTHOUSE.COM Introduction The pharmaceutical and medical device industries are developing
Cleanroom. For. Sterile Manufacturing Facilities
Cleanroom For Sterile Manufacturing Facilities Praphon Angtrakool Food and Drug Administration 1 WHO TRS No. 823 Annex 1, 1992 (1) General 17.1 The production of sterile preparations should be carried
Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations
Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations B e c k m a n C o u l t e r L i f e S c i e n c e s 2 5 0 S. K r a e m e r B o u l e
Manufacturing. Environmental Monitoring Particle Counts Are Easy B IOP ROCESSTECHNICAL. Scott E. Mackler
B IOP ROCESSTECHNICAL Environmental Monitoring Particle Counts Are Easy Scott E. Mackler Manufacturing pharmaceutical and biotechnology products requires that the appropriate level of quality be designed
ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS
ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS PRESENTATION TO RACI 20 TH APRIL 2016 PAUL MORGAN DIRECTOR CRITICAL CERTIFICATION PTY LTD CHANGES TO ISO14644 PART 1 CHANGES
Pharmagraph. GMP/GLP Monitoring System
Pharmagraph GMP/GLP Monitoring System Pharmagraph GMP/GLP Monitoring System Demonstrates GMP/GLP compliance for cleanrooms and laboratories Monitors, Alarms, Logs and Reports Airborne particle counts,
Environmental Monitoring of Clean Rooms
Environmental Monitoring of Raul Duarte President DDK Scientific, Corp. Copyright DDK Scientific, Corp. 2008, 2009, DDK Scientific, Corp. Proprietary A manufacturing facility for pharmaceutical products
CLEAN ROOM MONITORING REGULATORY STANDARDS
CLEAN ROOM MONITORING REGULATORY STANDARDS Air Classification as per Schedule M Maximum permitted number of particles / m3 equal or above at rest in operation 0.5µm 5.0µm 0.5µm 5.0µm A 3,520 29 3,500 29
The use of risk assessment tools for microbiological assessment of cleanroom environments. by Tim Sandle
The use of risk assessment tools for microbiological assessment of cleanroom environments by Tim Sandle Email: [email protected] / [email protected] Web: www.pharmig.blogspot.com Environmental
New changes to cleanroom & clean air device classifications: ISO 14644 1 & 2
New changes to cleanroom & clean air device classifications: ISO 14644 1 & 2 This white paper describes the changes outlined in the Draft International Standard (DIS) editions of ISO 14644-1 and ISO 14644-2.
Environmental Monitoring
Environmental Monitoring Purpose of Environmental Monitoring Critical process within the pharmaceutical and biotechnology industries. Determines the microbial and particulate content of cleanroom air and
Workflow System for Paperless Air Monitoring Powered by MODA. Presented by
Introducing Hach s MET ONE Compliance Workflow System for Paperless Air Monitoring Powered by MODA Presented by Scott Hjelmervik Bob Toal Systems Director Vice President Hach Company MODA Technology Partners
International Standard ISO 14644
International Standard ISO 14644 Cleanrooms and associated controlled environments Praphon Angtrakool Food and Drug Administration 1 International Standard : ISO 14644 ISO 14644 consists of the following
Environmental Monitoring
Chapter 10 Environmental Monitoring By the end of this chapter, you will be able to: l List the types of environmental testing l Name three types of checks that are carried out to ensure the isolator is
DRAFT GUIDANCE. This guidance document is being distributed for comment purposes only.
Guidance for Industry Current Good Manufacturing Practice Interim Guidance for Human Drug Compounding Outsourcing Facilities Under Section 503B of the FD&C Act DRAFT GUIDANCE This guidance document is
Design, Operation and Management of GTP/GMP Cell Engineering Facilities
Design, Operation and Management of GTP/GMP Cell Engineering Facilities Scott R. Burger, MD Advanced Cell & Gene Therapy BFDA 2007 International Symposium on Regulation of Human Cell and Tissue- Based
How To Control A Medical Device With A Pc System
Clean room monitoring and disinfection FMS 5.0, the Leading Facility Monitoring Software TSI FMS system is an advanced, reliable, and user-friendly monitoring software suite that features a truly open
Everything you want to know about USP 797
Everything you want to know about USP 797 Dr. Linda D. Lee Director of Operations Waste Management Healthcare Solutions September. 22, 2009 Goals High level understanding of USP 797 Who does it apply too
ENVIRONMENTAL MONITORING
ENVIRONMENTAL MONITORING Assessment and verification of the adequacy of the aseptic compounding environment is essential. Environmental monitoring programs are designed to promptly identify potential sources
Qualification of Cleanrooms and Environmental Monitoring - Practical Approaches in Europe
Qualification of Cleanrooms and Environmental Monitoring - Practical Approaches in Europe 1 Dr. Doris Herrmann Zum Eselsbachtal 20 67657 Kaiserslautern [email protected] www.gmp-unlimited.com
ISO 21501 A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners
ISO 21501 A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners Tony Harrison and Bob Latimer ISO 21501- A Standard Methodology to Optical Particle Counter
Particle Counting. - Theory - Guidelines - Monitoring
- Theory - Guidelines - Monitoring 1 Agenda Introduction to Cleanroom Classification of Air Cleanliness: ISO 14644 Guidance for the Manufacture of Sterile Medicinal Products EU GMP, Annex 1 Classification
Risk-Based Environmental Monitoring. Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI
Risk-Based Environmental Monitoring Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI Presenter Marsha Stabler Hardiman Over 20 years experience in the
DISCUSSION TOOL PRESENTED TO THE AABB CT REGULATORY AFFAIRS SUBSECTION
1 US FDA Form 483: A Case Study DISCUSSION TOOL PRESENTED TO THE AABB CT REGULATORY AFFAIRS SUBSECTION DEVELOPED BY FRAN RABE 2 Introduction This case study is intended to extract portions of information
Pharmaceutical Industry Whitepaper
Pharmaceutical Industry Whitepaper Cleanroom Data Management Challenges Labor and time intensive particle counting documentation can be streamlined Cleanroom Data Management Challenges Introduction Pharmaceutical
Contamination Control and Environmental Monitoring Systems
Life Science Contamination Control and Environmental Monitoring Systems Hospital Electronics Brookhaven Instruments deliver, install and validate particle counters, Microbial Air Samplers and Monitoring
Air and Water Balancing - Sound and Vibration Testing - Cleanroom Services - Building Commissioning Building Envelope Testing Thermal Imaging
NEUDORFER ENGINEERS, INC. provides our customer with unbiased, professional, performance testing of Cleanrooms. We are committed to providing you, our customer, with value-added expertise in an effort
EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union
EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Consumer goods Pharmaceuticals Brussels, 25 November 2008 (rev.) EudraLex The Rules Governing Medicinal Products in the European Union Volume
Sterile Cleanroom Management
Sterile Cleanroom Management Lynn Stanard, Sr. Quality Manager, Berkshire Corporation When manufacturing in an aseptic environment, it is critical to ensure that the various cleanroom consumables, such
ENVIRONMENTAL TESTING & MONITORING: Deciphering Compliance Requirements for Pharmaceutical and Medical Device Manufacturers A WHITE PAPER
A WHITE PAPER ENVIRONMENTAL TESTING & MONITORING: Deciphering Compliance Requirements for Pharmaceutical and Medical Device Manufacturers By Scott Mackin A WHITE PAPER ENVIRONMENTAL TESTING & MONITORING:
CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS
CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS UNDERSTANDING, ACCELERATED TSI SETS THE STANDARD FOR PARTICLE COUNTING Performance Semiconductor, hard disk drive, and flat panel manufacturers
Validating and Monitoring the Cleanroom
6 Validating and Monitoring the Cleanroom Kevina O Donoghue Overview... 6-1 Cleanroom Design... 6-1 Principles of Cleanroom Validation and Testing... 6-2 Cleanroom Validation... 6-2 So How Does One Determine
Compact Monitoring Technology your environmental monitoring solution
Compact Monitoring Technology your environmental monitoring solution Monitor your GxP environmental parameters and cut your validation costs. Solutions for Life Science and Hospitals www.siemens.com/cmt
Raleigh, NC May 12 th & 13 th 2016. Meeting The New ISO Cleanroom Standards And Changing EU Guidance How Will You Comply?
Raleigh, NC May 12 th & 13 th 2016 Meeting The New ISO Cleanroom Standards And Changing EU Guidance How Will You Comply? The International Cleanroom Standards (ISO 14644-1 & 2) have been updated, these
Design, Construction, Commission, and Qualification of Critical Utility Systems: Part III
Design, Construction, Commission, and Qualification of Critical Utility Systems: Part III BY DAVID W. VINCENT AND HERBERT MATHESON HEATING, VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEMS INTRODUCTION
BioLaz Real Time Microbial Monitoring in Aseptic Pharmaceutical Manufacturing. March 2013
BioLaz Real Time Microbial Monitoring in Aseptic Pharmaceutical Manufacturing March 2013 Introductions Gilberto Dalmaso, PMS Global Aseptic Processes Development Manager Who We Are: Particle Measuring
White Paper. Life Sciences Industry Solution Blueprint for Environmental Monitoring Systems (EMS) ISPE Guidance and Best Practices.
White Paper Life Sciences Industry Solution Blueprint for Environmental Monitoring Systems (EMS) Author: Roberto Zerbi, Global Industries Solutions Life Sciences, Invensys What s Inside: 1. Introduction
LyoBeta. R+D Freeze-Dryers
LyoBeta R+D Freeze-Dryers LyoBeta series A Responsible Choice New demands in R+D centers are related to scale-up feasibility and quality of procedures and research methods. FDA investigators consider that
The Environmental Monitoring Program In a GMP Environment
I, MICROBIOLOGY T PICS The Environmental Monitoring Program In a GMP Environment Scott Sutton "Microbiology Topics" discusses various topics in microbiology of practical use in validation and compliance.
Surface Scanning Probes for Lighthouse Particle Counters Solair Gen D/E
1. Why surface particulate detection? In many branches of industry the manufacture of an ultraclean surface is crucial to the functionality and quality of the product. Particles have an impact on the overall
USP <797> Cleanroom Design and Environmental Monitoring. Andrew King, USP <797> Specialist CETA Member RCCP-SC
USP Cleanroom Design and Environmental Monitoring Andrew King, USP Specialist CETA Member RCCP-SC Objectives The objectives of this presentation: To summarize basic cleanroom concepts and how
Basic Requirements For Aseptic Manufacturing Of Sterile Medicinal Products A Comparison Between Europe And USA
Basic Requirements For Aseptic Manufacturing Of Sterile Medicinal Products A Comparison Between Europe And USA Wissenschaftliche Prüfungsarbeit zur Erlangung des Titels Master of Drug Regulatory Affairs
11.I In-process control Authors: Dr. Christian Gausepohl / Paolomi Mukherji / Update 07
In-process control In-process control Authors: Dr. Christian Gausepohl / Paolomi Mukherji / Update 07 Here you will find answers to the following questions: What are the in-process control tasks? Where
SPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
Laminar Flow Cabinets and Workstations
VERTICAL AND HORIZONTAL HEPA FILTERED SYSTEMS FOR PROCESS OR OPERATOR PROTECTION Laminar Flow Cabinets and Workstations For procedures requiring protection from particulate contamination and for aseptic
Risk Based Environmental Monitoring (EM) and EM Data Management and Trending
Risk Based Environmental Monitoring (EM) and EM Data Management and Trending An Industry Roundtable Discussion Marsha Stabler Hardiman and Parsa Famili March 11, 2015 PDA NE Chapter Meeting Presenters
All Processes Dr. Paul Ruffieux Consultant
PSI-L Isolator Platform All Processes Dr. Paul Ruffieux Consultant 1 Requirements Is it possible to have one Isolator for Filling under aseptic conditions (Grade A) Use of isolator technology in ISO8 room
Guidance for Industry
Guidance for Industry Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products For questions on the content of the guidance,
Monitoring. Compliant and Reasonable. 5-6 May 2015, Berlin, Germany
Environmental Monitoring Workshops How to Establish an Environmental Monitoring Programme Interpretation of OOS Results Compliant and Reasonable 5-6 May 2015, Berlin, Germany SPEAKERS: Oxoid, UK Sauflon
Environmental Monitoring Risk Assessment
Environmental Monitoring Risk Assessment By Tim Sandle INTRODUCTION Environmental Monitoring describes the microbiological testing undertaken in order to detect changing trends of microbial counts and
Sandoz Private Limited 10/22/15
Sandoz Private Limited 10/22/15 Department of Health and Human Services Public Health Service Food and Drug Administration Silver Spring, MD 20993 Warning Letter VIA UPS WL: 320-16-01 October 22, 2015
Wireless Particle Monitoring of Pharmaceutical Cleanrooms
Wireless Particle Monitoring of Pharmaceutical Cleanrooms Introduction Wireless technology has brought many innovative changes, enabling us to communicate in new ways. This article will explain how wireless
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010 1. Background Class II Type B Biosafety Cabinets (BSCs) are unique laboratory
Environmental Monitoring of Clean Rooms in Vaccine Manufacturing Facilities
Environmental Monitoring of Clean Rooms in Vaccine Manufacturing Facilities Points to consider for manufacturers of human vaccines November 2012 Vaccine Quality and Regulations (VQR), Quality, Safety,
Combination Products. Presented by: Karen S. Ginsbury For: IFF March 2014. PCI Pharma
Combination Products Presented by: Karen S. Ginsbury For: IFF March 2014 Types of products Biological and medical device (freeze dried + syringe dual volume) Medical device and plasma devised product (syringe)
Understanding USP 797
DDK Scientific, Corp. Raul Duarte June 2008 Copyright DDK Scientific, Corp. 2008, 2009 DDK Scientific, Corp. Proprietary The purpose of USP 797 is to prevent harm and fatality to patients that could result
German engineering under high pressure
German engineering under high pressure Over 25 years of experience as a manufacturer of sterilizers, autoclaves and lyophilization systems for laboratories, production and research Production-scale autoclaves
cgmp Challenges for Cord Blood Banks
cgmp Challenges for Cord Blood Banks Donna M. Regan, MT(ASCP)SBB St. Louis Cord Blood Bank @ SSM Cardinal Glennon Children s s Medical Center Cord Blood Bank processing facility challenges What does cgmp
GUIDELINES ON TEST METHODS FOR ENVIRONMENTAL MONITORING FOR ASEPTIC DISPENSING FACILITIES
GUIDELINES ON TEST METHODS FOR ENVIRONMENTAL MONITORING FOR ASEPTIC DISPENSING FACILITIES PRODUCED BY A WORKING GROUP OF THE SCOTTISH QUALITY ASSURANCE SPECIALIST INTEREST GROUP SECOND EDITION FEBRUARY
Annex 6 WHO good manufacturing practices for sterile pharmaceutical products
World Health Organization WHO Technical Report Series, No. 961, 2011 Annex 6 WHO good manufacturing practices for sterile pharmaceutical products Introduction Following implementation of these WHO good
Monitoring manufacturing, production and storage environments in the pharmaceutical industry
Application Description AD/RandC/005-EN Monitoring manufacturing, production and storage environments in the pharmaceutical industry - Provides independent verification and validation of the manufacture,
VALIDATION OF CLEAN ROOMS FOR ASEPTIC MANUFACTURING. F.R.Smal Pharmaceutical Director ICCE ICCE a member of SNC-Lavalin Group
VALIDATION OF CLEAN ROOMS FOR ASEPTIC MANUFACTURING F.R.Smal Pharmaceutical Director ICCE ICCE a member of SNC-Lavalin Group tel + 3226431600 E-Mail: [email protected] VALIDATION OF CLEAN
Leila Kakko Tampere University of Applied science TRADITIONAL FOOD IN COMBATING FOODBORNE PATHOGENS 2011
Leila Kakko Tampere University of Applied science TRADITIONAL FOOD IN COMBATING FOODBORNE PATHOGENS 2011 World Food Programme Food quality control is necessary to ensure that food aid supplies are safe,
Validation of process gas systems
Validation of Process Gas Systems By Jeff Hargroves Alza Corporation Validation of process gas systems involve documenting the expected system behavior, and verifying that the system performs as expected.
Hazardous Drug. Cleanroom. Standards
Hazardous Drug Cleanroom Standards Module 3 Table of Contents Section A... 1 A.1 International Standards Organization (ISO) Classifications... 1 A.2 Hazardous Drug Cleanroom and Anteroom... 1 A.2.1 Location
Laminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested
DOP Solutions Technical Document: Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested Issue 1: Prepared by Neil Stephenson and Tim Triggs and edited by
Cleanrooms and associated controlled environments. Part 1: Classification of air cleanliness by particle concentration
INTERNATIONAL STANDARD ISO 14644-1 Second edition 2015-12-15 Cleanrooms and associated controlled environments Part 1: Classification of air cleanliness by particle concentration Salles propres et environnements
AMENDED January 27, 2015
Proposed Language To Amend 1735 in Article 4.5 of Division 17 of Title 16 of the California Code of Regulations to read as follows: 1735. Compounding in Licensed Pharmacies. (a) Compounding means any of
Facility Cleaning & Monitoring. Cleaning
Facility Cleaning & Monitoring Cleaning GTP Regulations: 21CFR Part 1271.190 Maintain facility in clean, sanitary & orderly manner Establish & maintain procedures for facility cleaning Assign responsibility
Library Guide: Pharmaceutical GMPs
Library Guide: Pharmaceutical GMPs Table of Contents Overview...3 Courses Listed by Functional Area... 4 Course Descriptions: A Step-by-Step Approach to Process Validation (PHDV79)... 7 A Tour of the FDA
Media fills Periodic performance qualification (Re-Validation)
Media fills Periodic performance qualification (Re-Validation) Minimum number of Simulations Number of units Contaminated Units Action a Two per Year (Retrospective & Prospective Validation) < 5000 5000
Cleaning validation of cleanrooms and preparation equipments
Cleaning validation of cleanrooms and preparation equipments Head of production Central Pharmacy, Geneva University Hospitals EAHP Foundation Seminar: Patient Safety; More About Compounding" 23-25 May,
Working Party on Control of Medicines and Inspections. Final Version of Annex 15 to the EU Guide to Good Manufacturing Practice
EUROPEAN COMMISSION ENTERPRISE DIRECTORATE-GENERAL Single market, regulatory environment, industries under vertical legislation Pharmaceuticals and cosmetics Brussels, July 2001 Working Party on Control
How single-use connections advance aseptic processing: Increased process flexibility and reliability, reduced costs
WHITE PAPER 7004 How single-use connections advance aseptic processing: Increased process flexibility and reliability, reduced costs By John Boehm Business Unit Manager Colder Products Company Today s
DIESEL FUEL CONDITIONING
COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency
The FDA recently announced a significant
This article illustrates the risk analysis guidance discussed in GAMP 4. 5 By applying GAMP s risk analysis method to three generic classes of software systems, this article acts as both an introduction
Corden Pharma Latina S.p.A. 5/20/16
Corden Pharma Latina S.p.A. 5/20/16 Department of Health and Human Services Public Health Service Food and Drug Administration Silver Spring, MD 20993 Via UPS Warning Letter 320-16-14 Return Receipt Requested
Guide to Master Formulae WHO/FWC/IVB/QSS/VQR
WHO/FWC/IVB/QSS/VQR 2011 This guidance document GUIDE TO MASTER FORMULAE is one of a series developed by WHO/FWC/IVB Quality, Safety & Standards team upon request from the manufacturers members of the
On-Site GMP Training GMP COMPLIANCE TECHNICAL
PharmaNet On-Site GMP Training GMP COMPLIANCE TECHNICAL 284 E Lake Mead Pkwy Suite C-278 Henderson, NV 89015 Phone: 702-558-0094 Fax: 702-558-0079 www.gmpseminars.com Key to Level of Program Level A: Program
VALIDATION OF ASEPTIC PROCESSES
PHARMACEUTICAL INSPECTION CONVENTION PHARMACEUTICAL INSPECTION CO-OPERATION SCHEME PI 007-6 1 January 2011 RECOMMENDATION ON THE VALIDATION OF ASEPTIC PROCESSES PIC/S January 2011 Reproduction prohibited
Elastomeric Components for Pharmaceutical Applications - Actual Quality Trends - Claudia Petersen. -Senior Manager Biotechnology-
Elastomeric Components for Pharmaceutical Applications - Actual Quality Trends - Claudia Petersen -Senior Manager Biotechnology- 2005 by West Pharmaceutical Services, Inc., Lionville, PA All rights reserved.
Revision of ISO 14644-1:1999 A progress report and explanation of some of the key issues and principles June 2012
Revision of ISO 14644-1:1999 A progress report and explanation of some of the key issues and principles June 2012 Gordon J Farquharson Convenor ISO TC209 WG1, Critical Systems Ltd, 4 Greencroft, Guildford,
Making SOP Training More Effective
By David Peterson, Director, GMP and Quality Systems, UL EduNeering SOPs are critical to efficient operations, quality control and regulatory compliance. This paper reviews best practices for the Life
FS209E and ISO Cleanroom Standards
FS209E and ISO Cleanroom Standards Terra Universal is the leading expert in the design and fabrication of critical-environment applications. We offer a complete range of equipment, furnishing and supplies
The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO
The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
Principles. of Pharmaceutical Facility Design. Full Time Part Time Online. www.dpseng.com.sg
Principles of Pharmaceutical Facility Design Full Time Part Time Online www.dpseng.com.sg Contents 1. Welcome 2. Programme Overview 3. Programme Content www.dpseng.com.sg 2 Welcome Transition into a new
Continuous Monitoring System. / REDUCE THE RISKS OF NON-COMPLIANCE & LOST PRODUCT IN GxP ENVIRONMENTS
Continuous Monitoring System / REDUCE THE RISKS OF NON-COMPLIANCE & LOST PRODUCT IN GxP ENVIRONMENTS Continuous Monitoring System (CMS) Overview A Scalable Solution Vaisala has been a global leader in
2016 > Emcure Pharmaceuticals Limited 3/3/16
Seite 1 von 7 U.S. Food and Drug Administration Protecting and Promoting Your Health Emcure Pharmaceuticals Limited 3/3/16 Department of Health and Human Services Public Health Service Food and Drug Administration
Monitoring the autoclaving process in the pharmaceutical industry
Application Description AD/RandC/006-EN Monitoring the autoclaving process in the pharmaceutical industry - Provides independent verification and validation monitoring of the autoclaving process - Enables