2 FAN FILTER DIFFUSER PRODUCT OVERVIEW TABLE OF CONTENTS Page No. 92FFD Series Fan Filter Diffusers Aluminum or Stainless Steel 3 Dimensional Data 4 Performance Data 5 ECM Technology 7 RMBC (Room-Side Removable Blower/Motor/Controls) 7 ECM Fan Controllers 8 MN ECM Fan Controller 8 AT ECM Fan Controller 8 Wall Mount 8 WMK Wall Mount Speed Control Kit 8 WMCP Wall Mount Cover Plate 8 Small System Console ACC1-10, ACC1-25, ACC1-50, ACC Overview System Intelligence Features Installation Specifications 9 Network Wiring Mounting Instructions 10 LFI - Loaded Filter Indicator Package HEPA/ULPA 11 Manifold/Challenge Port 12 Hand Held Remote Control 12 Scan Test Certificate 13 How to Order 14 How to Specify 15 Product Spotlight Critical Environment Applications 19 2 W92FFD2015 Copyright 2015 by Nailor Industries Inc. All rights reserved. No part of this catalog may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage and retrieval system without permission in writing from Nailor Industries Inc. In this catalog the terms of "Nailor Industries Inc.", "Nailor", "Nailor Industries" or "Nailor International Group" are synonymous and may be interchangeable for context or clarity. Nailor Industries Inc. pursues a policy of continuous product development and we therefore reserve the right to change any of the information in this publication without notice. Contact your Nailor representative to verify current product details.
3 FAN FILTER DIFFUSERS FAN FILTER DIFFUSERS ECM TECHNOLOGY ROOM SIDE REPLACEMENT FILTER DESIGNED FOR HEPA OR ULPA FILTER Models: 92FFD 92FFD-SS Aluminum Stainless Steel STANDARD FEATURES: # 4 Brushed Satin Polished finish (Model 92FFD-SS). AW Appliance White (Model 92FFD). Removable face plate for cleaning, filter replacement and secured by 1/4 turn fasteners. HEPA Filter (99.99% on 0.3 µm) is supplied as standard. Accepts HEPA/ULPA gel channel filters. High Efficiency ECM for precise constant airflow and field balancing. Available in (1 Ph, 60 Hz- 120V, 208V, 240V or 277V voltages). LED fan operation indicator (on during normal operation). Internal Urethane Foam insulation to reduce sound levels. Face accessible static pressure port (*for plenum side pressure readings). Heavy duty hanger brackets. Digital speed controller with airflow readout. Two stainless steel safety cables to prevent accidental dropping of removable face. Model 92FFD-SS Nailor 92FFD Series Fan Filter Diffusers consist of a unitary, welded stainless steel plenum, a removable perforated grille face, pressure independent EC motor and forward curved centrifugal blower. The fan/motor assembly is designed to supply HEPA/ULPA filtered air to a clean room environment and can be used in many applications such as microelectronics, pharmaceutical, biotechnology as well as aerospace manufacturing/assembly and laser/optics industries. All 92FFD Series Plenums are robotically welded to ensure a repeatable, rigid, clean, and near leak free design to verify the specified efficiency and leakage meets the most stringent of current leak tests. Each unit is built to IEST RP Standards and factory leak tested and serialized (HEPA filter only) with a PAO aerosol. A Scan Testing Certificate can be provided upon request. Model 92FFD comes with an aluminum perforated face and Type 304 stainless steel plenum. Model 92FFD-SS comes with a stainless steel perforated face and Type 304 stainless steel plenum. Filters are secured within the plenum against a continuous knife edge. The knife edge contacts the gel channel of the filter to provide a leak proof seal. Standard ECM (Electronically Commutated Motor) technology provides an ultra-energy efficient design with the ability to precisely set a constant air volume. Additionally, as filter loading increases fan external static pressure, the ECM will compensate to maintain set airflow. Extra benefits of using ECM technology include an improved motor life, wider airflow operating range, low heat generation and quiet operation. Optionally, motors and controls are room-side removable for easy access when servicing or replacing. All 92FFD Series products are ETL tested and listed to UL 507. Main power disconnect. PAO (Polyalphaolefin) Testing is on individual units to serialize leakage. CONSTRUCTION MATERIAL: Aluminum (Model 92FFD) or Type 304 Stainless Steel perforated face (Model 92FFD-SS) has 3/16" (5) diameter holes on 60 degree 1/4" (6) staggered centers (51% free area). The face plate is removable for cleaning, filter replacement and is secured by 1/4 turn fasteners. Type 304 stainless steel frame and fully welded plenum (all models). MATERIAL OPTIONS: Type 316 stainless steel construction (92FFD-SS only). FINISH OPTIONS: AW Appliance White (92FFD-SS). Visit our website at for additional product information. FILTER OPTIONS: ULPA Filter ( % on 0.12 µm). Filter by others. Loaded Filter Indicator Package-LFI (Adjustable, transformer included). Washable MERV 4 Pre-filter. Scan Testing Certificate STC is available for PAO Testing. MOTOR/CONTROL OPTIONS: Room-side removable Motor/Blower. Room-side removable Motor/Blower/ Controls. DUCTED OPTIONS: Round duct collars available in 10", 12" or 14" (254, 305 or 356). 3
4 FAN FILTER DIFFUSERS DIMENSIONAL DATA: 92FFD SERIES OPTIONAL INLET COLLAR FOR DUCTED APPLICATIONS W 1/4" (6) 51% FREE AREA PERFORATED FACE PRE-FILTER ACCESS DOOR FOR DUCTED UNITS MERV 4 WASHABLE PRE-FILTER STD. FOR NON-DUCTED APPLICATIONS. ECM DISCONNECT SWITCH INTEGRAL HANGER BRACKETS (4) 3 1/4" (83) 14 3/8" (365) D 1/8" (3) DIGITAL SPEED/ AIRFLOW CONTROLLER 2 1/2" (64) 4" (102) HANGER TABS (QTY. 4) STAINLESS STEEL WELDED PLENUM FILTER (HEPA/ULPA) 12 1/4" (311) HEPA OR ULPA FILTER PERFORATED FACE WITH QUARTER TURN FASTENERS L 1/4" (6) Models 92FFD and 92FFD-SS Ceiling Module Sizes L x W & Nominal Round Duct Sizes D L x W Imperial Modules (inches) 24 x 24 (610 x 610) 36 x 24(914 x 610) 48 x 24(1219 x 610) Metric Modules (mm) 600 x x x 600 Duct Size D (inches) (mm) 14 x 14 std. 10, 12, 14 opt. 356 x 356 std. 254, 305, 356 opt. 14 x 14 std. 10, 12, 14 opt. 356 x 356 std. 254, 305, 356 opt. 14 x 14 std. 10, 12, 14 opt. 356 x 356 std. 254, 305, 356 opt. Type S Surface Mount Detail CM 1/4" (6) Type L Lay-in T-Bar Detail CEILING MODULE SPP Static Pressure Port CEILING OPENING = CM 1 1/4" (32) KNIFE EDGE CM - 1/4" (6) KNIFE EDGE STATIC PRESSURE PORT KNIFE EDGE GEL SEAL GEL SEAL * COMPATIBLE WITH T-BARS UP TO 1 1/2" (38) WIDE GEL SEAL PORT CAP (Standard) 1 1/2" (38) wide or L20 (Optional) 2" (51) wide. 4 Visit our website at for additional product information.
5 FAN FILTER DIFFUSERS PERFORMANCE DATA: 92FFD SERIES FAN PERFORMANCE CURVES ECM With HEPA Filter 99.99% Minimum Removal Efficiency on 0.30 Micrometer Particle Size Unit Size 24" x 24" (610 x 610) 120V, 208V, 240V and 277V Fan Curves l/s 142 cfm 300 Maximum Airflow fpm 150 m/s 0.76 Airflow (CFM) % Filter Loading Pressure Drop 90 fpm Minimum Airflow Face Velocity (FPM) Initial Initial Filter Resistance Loaded Filter Static (" w.g.) Coefficient* " w.g Pa 1. A coefficient for factory supplied filter loading can be obtained from the provided line. IEST recommends the filter be 150% of initial pressure drop. 2. For example: If initial filter resistance =.5" w.g., use the provided line to estimate the additional static indicated airflow, for a 150% loaded filter. Add the additional static pressure to the initial pressure indicated airflow, to determine maximum allowable pressure drop. Unit Size 36" x 24" (914 x 610) 120V, 208V, 240V and 277V l/s 283 cfm 600 Fan Curves fpm 175 m/s Airflow (CFM) Maximum Airflow 90 fpm Minimum Airflow 150% Filter Loading Pressure Drop Face Velocity (FPM) Initial Initial Filter Resistance Loaded Filter Static (" w.g.) Coefficient* " w.g Pa 1. A coefficient for factory supplied filter loading can be obtained from the provided line. IEST recommends the filter be 150% of initial pressure drop. 2. For example: If initial filter resistance =.5" w.g., use the provided line to estimate the additional static indicated airflow, for a 150% loaded filter. Add the additional static pressure to the initial pressure indicated airflow, to determine maximum allowable pressure drop. Visit our website at for additional product information. 5
6 FAN FILTER DIFFUSERS PERFORMANCE DATA: 92FFD SERIES FAN PERFORMANCE CURVES ECM With HEPA Filter 99.99% Minimum Removal Efficiency on 0.30 Micrometer Particle Size Unit Size 48" x 24" (1219 x 610) 120V, 208V, 240V and 277V Airflow (CFM) l/s cfm Fan Curves Maximum Airflow Minimum Airflow 90 fpm 150% Filter Loading Pressure Drop fpm m/s Face Velocity (FPM) Initial Initial Filter Resistance Loaded Filter Static (" w.g.) Coefficient* " w.g Pa 1. A coefficient for factory supplied filter loading can be obtained from the provided line. IEST recommends the filter be 150% of initial pressure drop. 2. For example: If initial filter resistance =.5" w.g., use the provided line to estimate the additional static indicated airflow, for a 150% loaded filter. Add the additional static pressure to the initial pressure indicated airflow, to determine maximum allowable pressure drop. PERFORMANCE DATA: 92FFD SERIES ECM With HEPA Filter 99.99% Minimum Removal Efficiency on 0.30 Micrometer Particle Size Nominal Unit Size Voltage [V/PH/Hz] Active Filter Area [sq. ft.] Operating Range [fpm] Max. Airflow [cfm] Min. Airflow [cfm] 90 fpm [cfm] 90 fpm 90 fpm Initial 90 fpm [in. w.g.] Weight [lbs.] Motor Heat Gain [BTU] 24 x /1/ x /1/ x /1/ x /1/ x /1/ x /1/ x /1/ x /1/ x /1/ x /1/ x /1/ x /1/ fpm [dba] NOTES: 1. All airflow tested in accordance with current version of IEST-RP-CC002.3 UNI DIRECTIONAL FLOW, clean air devices. 2. Initial resistance refers to the static pressure associated with a clean filter at the corresponding face velocity. 3. Active filter area is based on factory supplied filter. Use of field supplied filters will result in different active filter areas. 4. Per IEST-RP-CC002.3, filters should be replaced once the internal static pressure has reached 1.5 times initial resistance at corresponding face velocity. 6 Visit our website at for additional product information.
7 92FFD SERIES ECM TECHNOLOGY/RMBC OPTIONS 92FFD SERIES ECM TECHNOLOGY FEATURES/ BENEFITS: Super quiet throughout all modes of operation. Up to 82% efficient, 30% greater than common PSC motors. Strong, integrated electronics with advanced thermal and overload protection Works with multiple voltages (120V, 208V, 240V and 277V) 1 Phase, 60 Hz Ability to precisely set a constant airflow Pressure independent airflow 92FFD SERIES RMBC (ROOM-SIDE REMOVABLE BLOWER/MOTOR/CONTROLS) Visit our website at for additional product information. 7
8 92FFD SERIES ECM FAN CONTROLLER/WMK MN ECM FAN CONTROLLER: The ECM-VCU (Visual Control Unit) is a manual volume controller that provides precise manual adjustment and monitoring of the fan when used with an ECM. The ECM controller features a 4 digit LED numerical display, providing excellent legibility of numbers, especially when viewing in dark spaces. The flow index is set and adjusted with a screwdriver. After 20 seconds, the board will display cfm and then alternate between calculated cfm and percent torque (flow index). AT ECM FAN CONTROLLER: The ECM ACU+ is an Auto/Dynamic Volume Control that adjusts and monitors the ECM by using 0 10 Vdc analog input. The motor is factory programmed to provide constant mass airflow over the configured control range. The interface provides remote adjustment of the ECM output with a programmed control range of 0 100%. A signal lamp on the control continually flashes out the flow index. Instruments are not required to read the airflow value. Jumpers allow the interface to be configured for 0 10 Vdc, or 2 10 Vdc or manual/override control. The interface can also be used for stand alone manual control. ECM VCU ECM ACU+SERIES I Motor Automation Control Unit ADJUST F 6 8 RPM % Motor Output ECM Motor Control Status Adjust MN Manual Volume Control AT Auto/ Dynamic Volume Control WMK WALL MOUNT SPEED CONTROL KIT Overview: Nailor Model WMK is a wall mounted speed controller that provides convenient airflow adjustment in the occupied zone without the use of tools. The WMK provides a potentiometer to vary the speed of a single unit set-up in analog mode. This option is recommended for single units installed in locations where access to the unit mounted volume controller is inconvenient or for applications where frequent adjustment of the volume is required. "WMK is easily field installed by a qualified electrician. The WMK is provided with a lead and 7-way connector as standard that simply plugs into the face of the factory installed ECM fan volume controller". INCREASE WALL MOUNT COVER PLATE: Included with every purchase of the WMK, the Stainless Steel wall plate comes standard with mounting screws. 8 Visit our website at for additional product information.
9 SMALL SYSTEM CONSOLE ACC1-10, -25, -50, -125 SMALL SYSTEM CONSOLE ACC1-10, ACC1-25, ACC1-50, ACC1-125 Overview: The Small System Console intelligently monitors and controls the ECM network. The console provides communication (MODBUS-RTU platform), unit control and system monitoring, consolidated into a simplified all-in-one package. With the help of a user friendly, menu driven format, no programming is necessary to install a network. The console automatically scans the network, allowing the units/system to be configured through the menu. The Small System Console is a single zone that has 4 available models to choose from, with the ability to control up to 10, 25, 50 or 125 network addressed units. System Intelligence: Self-configuration upon start-up. Individual speed adjustment. Global speed adjustment. Global set-back speed adjustment. Central monitoring of fault sensors (pressure drop on AC, RPM drop on EC type). Menu driven configuration options. Monitors units and identifies error modes. Features: Simple wall mount. 4 access levels to control modifications. User friendly interface. 7 segment LED display. Dual rotary encoders for selection and adjustment. Supports small to medium scale networks. RS 485 (2 wire) Up to 125 slave nodes Installation: The Small System Console (MODBUS Controller) can be mounted to the wall in the cleanroom or at a remote location. Maximum distance from the beginning to end of the daisy chain should not exceed 800 linear feet. ECM fan cards are pre-set with a unique address with a range of the MODBUS. DC power to the console can be provided by CAT5 network cable, Battery Pack (4) x AA batteries or Power Supply Module connected to the DC power jack. Once the control console has been connected to at least one fan filter diffuser, power can be applied. Specifications: Supply Voltage: 8 13 Vdc Common Supply Current: 90 ma Batteries: 4 x AA size (battery life: typically 30 hours) Network Transceivers: 2-wire 1/8" unit load type Operating Temperature: 32 F to 104 F Electrical Connections DC Power Connector: 2.1 mm DC Power Jack MODBUS Network: RJ45 socket SELECTED UNIT (ADDRESS) STATUS OF SELECTED UNIT SPEED OF SELECTED UNIT SELECT ADJUST ACC1-25 Small System Console Console Operation: Front and Panel View ROTATE TO SELECT UNIT OR OPTION MENU. PUSH TO ENTER OPTION MENU. ROTATE TO ADJUST SPEED OR OPTION SETTINGS. Visit our website at for additional product information. 9
10 SMALL SYSTEM CONSOLE ACC1-10, -25, -50, -125 SMALL SYSTEM CONSOLE ACC1-10, ACC1-25, ACC1-50, ACC1-125 Network Wiring: A network is constructed by simple daisy-chaining between the ACC1-XXX and the unit controls. Network cable requirements should be specified based on: Distance between nodes. Total network length Noisy electrical environment Environmental conditions Mechanical issues Pre-terminated cables are available and are suitable for many small system installations. Upon start-up, the console will automatically scan the controls. ECM INTERFACE CAT5 CABLING ECM MOTOR ECM MOTOR ECM MOTOR AC POWER 12 VA TRANSFORMER POWER SUPPLY SELECT ADJUST ACC1-25 Small System Console CONSOLE Mounting Instructions (Two Options): ACC1-XX System Diagram Permanent Installation: Using the 4 outer holes (top and bottom) on the ACC1, the console can be permanently mounted to any desired location. *Please note that a wall outlet must be near the mounting location if the ACC1 is powered through a wall adaptor. An alternative is to power the ACC1-XXX through the CAT5 cable.* 3.50" (89) 2.0" (51) Removable Installation: The key holes in the center of the ACC1 can be used to hang the ACC1 in any desired location. **Note: The Nailor MODBUS controllers have memory of the set point and provide local control of their motor/fan - removing the ACC1-XXX will not shut down the system. The system will continue to run until the ACC1-XXX is reconnected and the set-point modified.** 7.0" (178) SELECT 6.0" (152) 6.125" (156) ADJUST ACC1-25 Small System Console Mechanical Dimensions 10 Visit our website at for additional product information.
11 LFI LOADED FILTER INDICATOR PACKAGE HEPA/ULPA LFI LOADED FILTER INDICATOR PACKAGE: Nailor s LFI Loaded Filter Indicator Package is offered as an option for the 92FFD Series Fan Filter Diffusers and provides convenient room-side visibility of filter condition and ECM status. On a standard Fan Filter Diffuser, where components are serviced from above the ceiling, the LFI package comes with two LED lights (1 green, 1 red). The green light is connected to a pressure switch to show that the unit is running. The light does not communicate that there is power to the unit, only that the blower wheel is spinning. The red light will turn on when the pressure set-point for filter replacement has been reached. When RMB/RMBC (Room-side removable Blower/Motor/Controls) options are selected for the Fan Filter Diffusers, three LED lights will be provided with the LFI package (2 Green, 1 Red). One of the Green lights will communicate that the blower wheel is spinning and the second Green light will display that the 24V circuit is on. Both of the Fan Operation Indicator Lights (Green LEDs) will be on during normal operation, which allows for external monitoring of motor functionality. The Red light will illuminate only when the filter has built up enough pressure inside the unit where it needs to be replaced. The LFI package comes standard with an adjustable 24V transformer and factory installed pre-calibrated switch that can be field adjusted if required. Maximum available pressure setting is 1.0" w.g. NAILOR HEPA/ULPA FILTERS Introduction: Model 92GSF-HE HEPA filters and Model 92GSF-UL ULPA filters are designed to fit in Nailor 92LFD, 92RPD and 92FFD Series products, which are ideal for use in cleanroom applications such as pharmaceutical, microelectronics, biotechnology as well as aerospace manufacturing/assembly and laser optic industries. The HEPA/ULPA filters are designed with mini-pleated wet laid glass media with efficiencies ranging from 99.99% on 0.3 µm particle size (HEPA) and % on 0.12 µm particle size. The filters incorporate an anodized extruded aluminum frame and a 2" (51) deep separatorless media pack with an overall height of 5.25". All filters are UL 900 Class 1 listed. Each filter is constructed per IEST-RP-CC001.5 standards and individually scan tested in accordance with IEST-RP-CC Filters are packaged independently from the diffuser for final installation in the field (by others). Filters cannot and will not be shipped installed. FEATURES: Maximized media content for lower pressure drop and extended service life. 70% open face screen keeps the high performance of the media intact. Aluminum frame reduces weight and need for structural support. Hot melt beads protect pack from screen. BENEFITS: Lower Energy Cost Low Pressure Drop Easy Installation, Light Weight No Media Damage Visit our website at for additional product information. 11
12 92FFD SERIES DOP/PAO CHALLENGE PORT HHRC DOP/PAO CHALLENGE: Nailor uses robotically welded plenums and gel channel filters. Each filter is constructed pet IEST-RP-CC001.5 standards and individually scan tested in accordance with IEST-RP-CC Our plenums have robotically welded seams and a unitized design. How it works: DOP/PAO Scan Testing is performed by using a photometer with a hand held probe. The probe is held or attached to the air exhaust of the unit. The photometer display indicates the percentage of leakage through or around the filter. By initializing the Aerosol Generator, the production of DOP/PAO occurs, directing the aerosol to the inlet/filter side of the unit, permitting the HEPA unit to draw the media through the filter and blower. The test aerosol is introduced into the system to challenge the HEPA filter and seals on the upstream side of the filter. This can be achieved by aerosol passing through the mixing chamber, creating adequate mixing of the aerosol with the airflow in the duct or by directing the generated particles over entire filter media and around filter edges to test seal. Good design Stringent leak tests Ensures a near leak free design COMING DOWN MIXING COMING OUT AEROSOL INJECTION HHRC HAND HELD REMOTE CONTROL: Nailor HHRC is an infrared remote control system that remotely changes the airflow of the Fan Filter Diffuser. The ECM allows adjustment of the airflow between the manufacturers programmed minimum and maximum, which is achieved by setting the airflow index between in the control. The HHRC sends modulated infrared signals to a receiver on the control. The control may be mounted on or near the equipment. A flow index lamp flashes out the motor s output, so instruments are not required to adjust or record the air balance setting. A red status lamp indicates the motor is powered and turning. Lamps and the infrared sensor may be mounted on the control or remoted to accommodate a wide variety of equipment configurations. 12 Visit our website at for additional product information.
13 SCAN TEST CERTIFICATE HEPA FILTER ENCLOSURE TEST REPORT ID Number: Client: Address: City, State, Zip: Contact Number: Phone: TEST INSTRUMENTATION Date: Test Results Pass See Comments Fail Pending Action M/N (Enclosure): S/N (Enclosure): Technician: Manufacturer (filter): Filtrair P/N (filter): S/N (filter): Filter Specs: 43.5 x 19.5 x 2 HEPA Air Data: Manufacturer: M/N: S/N: Alnor EBT Aerosol Photometer: Manufacturer: TEC Services M/N: PH-4 S/N: 1204 Aerosol (PAO) Generator: Manufacturer: TEC Services M/N: AG-E1 S/N: 1177 LEAK TEST: PERFORMED WITH 1.5 LASKIN RES. = 0.50 TEST 1 Airflow: 300 cfm Leaks Detected: Media Plaster Frame Corner Gasket Test Comments: TEST 2 Airflow: Leaks Detected: Media Plaster Frame Corner Gasket Test Comments: TEST 3 Airflow: Leaks Detected: Media Plaster Frame Corner Gasket Test Comments: PASS Setup Comments: Test equipment has been performance tested in accordance with: Owner s Specifications Manufacturer s Specifications NSF Standard 49 IEST-RP-CC034.3 IEST-RP-CC021 Technician Signature: The information contained in this report is intended for the sole use of the individual or entity named above. Review, dissemination, distribution, or copying of this report is prohibited without the prior consent of Nailor Industries Inc. This report is applicable to the condition of the enclosure as it was shipped from the Nailor Industries Inc. facility. Nailor Industries Inc. is not responsible for leakage due to damage incurred during shipping or installation. 13
14 92FFD SERIES HOW TO ORDER MODEL SERIES: 9200 FAN FILTER DIFFUSER MODEL SERIES 92FFD ALUMINUM OR STAINLESS STEEL EXAMPLE: 92FFD-SS - 48 x L - #4 - V18 - MN - HE PFM4 - SPP - QF 1. Model OPTIONS AND ACCESSORIES: Notes: 92FFD Aluminum (Default is none unless noted otherwise) 92FFD-SS Stainless Steel 10. Pre-Filter PFM4 MERV4 Washable Pre-filter (default for 14" x 14" [356 x 356] inlet) None (default for round inlet) 2. Ceiling Module Size Imperial Modules inches (mm s) 24" x 24" (610 x 610) 36" x 24" (914 x 610) 48" x 24" (1219 x 610) Metric Modules (mm s) 600 x x x Inlet Size inches " x 14" (356 x 356) Non-ducted (default) 10 10" (254) dia. round collar 12 12" (305) dia. round collar 14 14" (356) dia. round collar 4. Frame Type L Lay-in T-Bar (up to 1 1/2" [38] wide) (default) S Surface Mount L20 Lay-in T-Bar 2" (51) wide 5. Finish AW Appliance White (default 92FFD) #4 Brushed Satin Polished (default 92FFD-SS) 6. Fan Motor Voltage V18 120V/1PH/60Hz ECM V19 208V/1PH/60Hz ECM V20 240V/1PH/60Hz ECM V21 277V/1PH/60Hz ECM 7. ECM Fan Card MN Manual Volume Control (default) AT Auto/Dynamic Volume Control, 0 10 Vdc 8. Filter Type HE HEPA (99.99% on 0.3 μm) (default) UL ULPA ( % on 0.12 μm) FBO Filter by others 9. Construction (-SS) 304 Type 304 Stainless Steel (default) 316 Type 316 Stainless Steel (Model 92FFD-SS only) 11. SP/DOP Port SPP Static Pressure Test/DOP Port (default) 12. Disconnect Switch QF Toggle Type (default) 13. Filter Indicator LFI LED Loaded Filter Indicator Package (adjustable, transformer included) 14. Removable Option RMB Room-Side Removable Motor/Blower RMBC Room-Side Removable Motor/Blower/Controls 15. DOP/ PAO Challenge CPM Challenge Port and Manifold 16. Control Option WMK Wall Mount Speed Control Kit HHRC Hand Held Remote Control 17. Scan Testing Certificate STC Scan Testing Certificate 1. Finish: AW Appliance White is the only finish available for Model 92FFD. 2. ECM with LED digital display volume controller is standard. 3. PFM4 MERV4 Washable Pre-filter is standard on non-ducted units and optional on ducted (round collar) units. Pre-filter access door for ducted units. 4. Consult price pages as to limitations of module and neck size combination. 14 Visit our website at for additional product information.
15 92FFD SERIES HOW TO SPECIFY MODEL 92FFD (ALUMINUM) FAN FILTER DIFFUSERS SUGGESTED SPECIFICATIONS: GENERAL: Furnish and Install Nailor Model 92FFD Fan Filter Diffusers of the sizes and capacities shown on the plans and air distribution schedules. CONSTRUCTION: 1.00 The unit shall be constructed and classified in accordance with IEST-RP-CC The perforated face of the diffuser shall be constructed with 0.032" aluminum alloy (AL3003) and have 3/16" (5) diameter holes on 60 1/4" (6) staggered centers with 51% free area The face shall be attached with 1/4 turn fasteners to allow for complete removal and access to the interior for cleaning. All diffusers are to include safety cables to prevent accidental dropping of the removable face Frame Type shall be either Lay-in T-Bar suitable for flat ceiling tees, up to 1 1/2" (38) wide, or Surface Mount All room-side exposed surfaces shall have AW Appliance White powder coat finish Inlet size shall be 14" x 14" (356 x 356) for non-ducted applications and include a MERV 4 washable pre-filter The diffuser plenum shall be robotically welded 304 stainless steel, minimum 20 ga. (1.0). The diffuser plenum shall incorporate an integral filter frame to accommodate a Gel Seal Filter of type HEPA or ULPA. Integral hanger tabs shall be included and shall be permanently welded to the plenum. Hanger tabs using mechanical fasteners are not acceptable Fan Filter Diffusers shall be strategically lined with 1.25" thick internal urethane foam insulation attached to the bottom of the plenum and 0.75" on the mid panel, both surrounding the fan, for sound attenuation A static pressure port shall be included for upstream filter static pressure measurements. The pressure port shall be factory installed and factory leak tested prior to shipment Factory leak testing of the Fan Filter Diffuser assembly shall be provided using a PAO (Poly-Alpha-Olefin) aerosol in accordance with IEST-RP-CC Filters shall be securely held in place by at least four mounting brackets allowing filter removal from the face of the diffuser without disturbing the installed ductwork or the diffuser mounting surface. The mounting bracket assembly shall not compromise the integrity of the knife edge assembly with any through penetrations of the knife edge. FILTERS: 2.01 The filters efficiency shall be HEPA: 99.99% minimum removal efficiency on 0.30 micrometer particle size. Filters shall incorporate an anodized extruded aluminum frame and 2" (51) deep separatorless filter pack. Filters shall incorporate a removable test port, to measure filter pressure drop or to perform leakage (scan) tests All filters shall be UL 900 Class 1 Listed and Factory Mutual Approved. All filters shall be constructed per IEST-RP-CC001.5 standards and individually scan tested in accordance with IEST-RP-CC Filters shall be packaged independently from the diffuser for final installation in the field (by others). Filters cannot and will not be shipped installed. PERFORMANCE: 3.01 The manufacturer shall provide published performance data for the diffuser, which shall be tested in accordance with ANSI/ASHRAE Standard Motor shall be a high efficiency ECM for precise constant airflow and field balancing, complete with integrated electronics, advanced thermal and overload protection. The following motor specifications shall apply: Frame Size 48 1 Phase, 60HZ Available Voltages: 120V, 208V, 240V, 277V Operation Modes: Constant CFM Blower wheel shall be forward curved centrifugal type, dynamically balanced and driven by direct drive ECM Motor/Blower assembly shall be accessible and removable from the top of the unit. CONTROLS: 4.01 Non-ducted units shall be ETL listed to UL ECM Fan Card shall be a manual volume controller that provides precise manual adjustment of CFM and monitoring of the fan when used with the ECM. The display shall include a backlit and clearly legible digital readout LED fan operation indicator shall remain on during normal operation and be room-side visible Toggle type disconnect switch shall be provided with all units for main power on/off. 15
16 92FFD SERIES HOW TO SPECIFY MODEL 92FFD (ALUMINUM) FAN FILTER DIFFUSERS (continued) SUGGESTED SPECIFICATIONS: OPTIONS: Construction Substitute the following paragraph(s): 1.03 Frame type shall be either Lay-in T-bar suitable for flat ceiling tees, up to 2" (51) wide, or Surface Mount. T-Bar frame type L20 shall be specified Ducted units shall be provided with 10", 12" or 14" (254, 305 or 356) round inlet and optional MERV 4 pre-filter with access door Factory leak testing of the Fan Filter Diffuser assembly shall be provided using a PAO aerosol in accordance with IEST-RP-CC A Scan Testing Certificate shall be provided for individual unit serialization A PAO dispersion manifold, with unit integrated challenge port, shall be factory installed and accessible without removal of the filter. Filters Substitute the following paragraph(s): 2.01 The filter efficiency shall be ULPA: % minimum removal efficiency on 0.12 micrometer particle size. Filters shall incorporate an anodized extruded aluminum frame and removable test port, to measure filter pressure drop or to perform leakage (scan) tests Unit shall be provided with LFI Loaded Filter Indicator package to provide room-side visibility of filter condition and ECM status. Performance Substitute the following paragraph(s): 3.04 Blower/Motor assembly shall be accessible and replaceable from the room-side, option code RMB Blower/Motor/Controls shall be accessible and replaceable from the room-side, option code RMBC. Controls Substitute the following paragraph(s): 4.02 Unit shall be provided with a wall mounted speed control potentiometer to vary the speed of a single unit set-up in analog mode (shipped loose for field installation) MODBUS controller shall be provided with the unit, which monitors and controls the ECM network (shipped loose for field installation) Unit shall be provided with an Auto/Dynamic Volume Control that adjusts and monitors the ECM by using 0V to + 10V AC or DC automation signals. The interface provides remote BAS adjustment of the ECM output with a programmed control range of 0-100%. 16 Visit our website at for additional product information.
17 92FFD-SS SERIES HOW TO SPECIFY MODEL 92FFD-SS (STAINLESS STEEL) FAN FILTER DIFFUSERS SUGGESTED SPECIFICATIONS: GENERAL: Furnish and Install Nailor Model 92FFD-SS Fan Filter Diffusers of the sizes and capacities shown on the plans and air distribution schedules. CONSTRUCTION: 1.00 The unit shall be constructed and classified in accordance with IEST-RP-CC The perforated face of the diffuser shall be constructed with 304 stainless steel and have 3/16" (5) diameter holes on 60 1/4" (6) staggered centers with 51% free area The face shall be attached with 1/4 turn fasteners to allow for complete removal and access to the interior for cleaning. All diffusers are to include safety cables to prevent accidental dropping of the removable face Frame Type shall be either Lay-in T-Bar suitable for flat ceiling tees, up to 1 1/2" (38) wide, or Surface Mount All room-side exposed surfaces shall have #4 Brushed Satin Polished finish Inlet size shall be 14" x 14" (356 x 356) for non-ducted applications and include a MERV 4 washable pre-filter The diffuser plenum shall be robotically welded 304 stainless steel, minimum 20 ga. (1.0). The diffuser plenum shall incorporate an integral filter frame to accommodate a Gel Seal Filter of type HEPA or ULPA. Integral hanger tabs shall be included and shall be permanently welded to the plenum. Hanger tabs using mechanical fasteners are not acceptable Fan Filter Diffusers shall be strategically lined with 1.25" thick internal urethane foam insulation attached to the bottom of the plenum and 0.75" on the mid panel, both surrounding the fan, for sound attenuation A static pressure port shall be included for upstream filter static pressure measurements. The pressure port shall be factory installed and factory leak tested prior to shipment Factory leak testing of the Fan Filter Diffuser assembly shall be provided using a PAO (Poly-Alpha-Olefin) aerosol in accordance with IEST-RP-CC Filters shall be securely held in place by at least four mounting brackets allowing filter removal from the face of the diffuser without disturbing the installed ductwork or the diffuser mounting surface. The mounting bracket assembly shall not compromise the integrity of the knife edge assembly with any through penetrations of the knife edge. FILTERS: 2.01 The filters efficiency shall be HEPA: 99.99% minimum removal efficiency on 0.30 micrometer particle size. Filters shall incorporate an anodized extruded aluminum frame and 2" (51) deep separatorless filter pack. Filters shall incorporate a removable test port, to measure filter pressure drop or to perform leakage (scan) tests All filters shall be UL 900 Class 1 Listed and Factory Mutual Approved. All filters shall be constructed per IEST-RP-CC001.5 standards and individually scan tested in accordance with IEST-RP-CC Filters shall be packaged independently from the diffuser for final installation in the field (by others). Filters cannot and will not be shipped installed. PERFORMANCE: 3.01 The manufacturer shall provide published performance data for the diffuser, which shall be tested in accordance with ANSI/ASHRAE Standard Motor shall be a high efficiency ECM for precise constant airflow and field balancing, complete with integrated electronics, advanced thermal and overload protection. The following motor specifications shall apply: Frame Size 48 1 Phase, 60HZ Available Voltages: 120V, 208V, 240V, 277V Operation Modes: Constant CFM Blower wheel shall be forward curved centrifugal type, dynamically balanced and driven by direct drive ECM Motor/Blower assembly shall be accessible and removable from the top of the unit. CONTROLS: 4.01 Non-ducted units shall be ETL listed to UL ECM Fan Card shall be a manual volume controller that provides precise manual adjustment of CFM and monitoring of the fan when used with the ECM. The display shall include a backlit and clearly legible digital readout LED fan operation indicator shall remain on during normal operation and be room-side visible Toggle type disconnect switch shall be provided with all units for main power on/off. 17
18 92FFD-SS SERIES HOW TO SPECIFY MODEL 92FFD-SS (STAINLESS STEEL) FAN FILTER DIFFUSERS (continued) SUGGESTED SPECIFICATIONS: OPTIONS: Construction Substitute the following paragraph(s): 1.03 Frame type shall be either Lay-in T-bar suitable for flat ceiling tees, up to 2" (51) wide, or Surface Mount. T-Bar frame type L20 shall be specified All room-side exposed surfaces shall have AW Appliance White powder coat finish Ducted units shall be provided with 10", 12" or 14" (254, 305 or 356) round inlet and optional MERV 4 pre-filter with access door Factory leak testing of the Fan Filter Diffuser assembly shall be provided using a PAO aerosol in accordance with IEST-RP-CC A Scan Testing Certificate shall be provided for individual unit serialization A PAO dispersion manifold, with unit integrated challenge port, shall be factory installed and accessible without removal of the filter. Filters Substitute the following paragraph(s): 2.01 The filter efficiency shall be ULPA: % minimum removal efficiency on 0.12 micrometer particle size. Filters shall incorporate an anodized extruded aluminum frame and removable test port, to measure filter pressure drop or to perform leakage (scan) tests Unit shall be provided with LFI Loaded Filter Indicator package to provide room-side visibility of filter condition and ECM status. Performance Substitute the following paragraph(s): 3.04 Blower/Motor assembly shall be accessible and replaceable from the room-side, option code RMB Blower/Motor/Controls shall be accessible and replaceable from the room-side, option code RMBC. Controls Substitute the following paragraph(s): 4.02 Unit shall be provided with a wall mounted speed control potentiometer to vary the speed of a single unit set-up in analog mode (shipped loose for field installation) MODBUS controller shall be provided with the unit, which monitors and controls the ECM network (shipped loose for field installation) Unit shall be provided with an Auto/Dynamic Volume Control that adjusts and monitors the ECM by using 0V to + 10V AC or DC automation signals. The interface provides remote BAS adjustment of the ECM output with a programmed control range of 0-100%. 18 Visit our website at for additional product information.
19 Product SPOTLIGHT C r i t i c a l E n v i r o n m e n t A p p l i c a t i o n s 92FFD Fan Filter Diffusers Nailor 92FFD Series Fan Filter Diffusers are fan powered diffusers with integrated high efficiency filters for critical environment applications. The diffusers are designed to supply HEPA/ULPA filtered air to a critical environment and are intended for use in cleanroom applications such as microelectronics, pharmaceutical, biotechnology as well as aerospace manufacturing/assembly and laser/optic industries. Filters are secured within the plenum against a continuous knife edge. The knife edge contacts the gel channel of the filter to provide a leak proof seal. Filters are room-side removable via quarter turn fasteners. All 92FFD Series Plenums are robotically welded to ensure a consistent, rigid, clean and relatively leak free design to verify the specified efficiency and leakage to meet the most stringent of current leakage tests. Each unit is PAO Scan Tested to IEST-RP-CC034.3 Standard to ensure leakage is consistent with an uncompromised filter. Premium design features and high quality construction include a removable face for room-side filter replacement. This enables the integrity of the clean space to be maintained as the ceiling does not need to be penetrated. Standard ECM technology provides an ultra-energy efficient design with the ability to precisely set a constant air volume. Additionally, as filter loading increases fan external static pressure, the ECM will compensate to maintain set airflow. Standard FEATURES Aluminum or Type 304 Stainless Steel construction 304 Stainless Steel Fully welded plenum High Efficiency ECM for reduced energy consumption, pressure independent airflow and simplified field balancing Internal Urethane Foam Insulation to reduce noise LED fan operation indicator (on during normal operation) #4 Brushed Satin Polished finish (SS) and AW Appliance White (AL) Two SS Safety Cables to prevent accidental dropping of face Digital speed controller with airflow readout Heavy duty hanger brackets ETL Listed and Tested to UL 507 Standard Face accessible static pressure port MERV 4 Washable Pre-Filter (non-ducted applications) HEPA filter (99.99% on 0.3 μm) Toggle disconnect switch Options Type 316 Stainless Steel Construction ULPA Filter ( % on 0.12 μm) Room-side removable Motor/Blower Room-side removable Motor/Blower/Controls Loaded Filter Indicator Package PAO Manifold for challenge test Inlet collar for ducted applications Wall mounted speed controller
20
MAC 10. Original & IQ FAMILY OF FAN FILTER UNITS
MAC 10 Original & IQ FAMILY OF FAN FILTER UNITS used in: microelectronics medical device semiconductor disk drive laboratory pharmaceutical markets hospitals clean rooms Table of Contents MAC 10 Original
T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ
TSQ--0 7-7-07 T Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T SQ Model Configuration T SQ- Heating / Cooling Border Type (Lay-In) Full Face Nominal Round Duct Size
plenum slot diffusers
light powered Redefine your comfort zone. www.titus-hvac.com dual-function smart logic light powered energy solutions Table of Contents PLENUM SLOT IFFUSERS products Plenum Slot iffusers Products... 4
INSTALLATION, OPERATION & MAINTENANCE Fan Filter Units CRFF, CRFF-ARS, & CRFF-ARSM PSC Motors. Revision: 10.01.13
INSTALLATION, OPERATION & MAINTENANCE Fan Filter Units CRFF, CRFF-ARS, & CRFF-ARSM PSC Motors Revision: 10.01.13 Page: 2 of 12 Critical operation conditions of the CRFF, CRFF-ARS and CRFF-ARSM 1. Touching
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
Laminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Lighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Digi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
E-PDD Duct Smoke Detector Installation Sheet
E-PDD Duct Smoke Installation Sheet Operation The duct smoke detector's primary purpose is to provide early warning of an impending fire and shut down the HVAC unit in order to prevent smoke from circulating
Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
MAC 10 Original VE5 FAN FILTER MODULE INSTALLATION AND SERVICE MANUAL
*** READ AND SAVE THESE INSTRUCTIONS *** R R MAC 10 Original VE5 FAN FILTER MODULE INSTALLATION AND SERVICE MANUAL STANDARD, RSR, RSRE MODELS R R Mac 10 and VE5 are registered Trademarks of the Envirco
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
MAC 10 DC-LE FAN FILTER MODULE INSTALLATION AND SERVICE MANUAL
*** READ AND SAVE THESE INSTRUCTIONS *** MAC 10 DC-LE FAN FILTER MODULE INSTALLATION AND SERVICE MANUAL STANDARD, RSR, RSRE MODELS Mac 10 and VE5 are registered Trademarks of the Envirco, U.S.A. US Patents
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
security products metric sizes Redefine your comfort zone. www.titus-hvac.com
metric sizes secure lethal objects monitoring areas suicide deterrent Redefine your comfort zone. www.titus-hvac.com humid areas prevents corrosion minimum security medium security maximum security Table
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD
WIRELESS STATUS MONITOR
INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
CE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health
Background Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health This document provides guidelines for the design and installation of Class
FIRE DAMPER APPLICATION GUIDE
FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire
VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP
VIEW SLX300 SpeakerLinX IP Zone Amplifier Installation and Setup Guide TM AVoIP ClearOne 5225 Wiley Post Way Suite 500 Salt Lake City, UT 84116 Telephone 1.800.283.5936 1.801.974.3760 Tech Sales 1.800.705.2103
Fan Coil EC Motor Control
Fan Coil EC Motor Control G3 PWM BARD The Enviro-Tec Generation 3 PWM (G3 PWM) board provides a pulse-width modulated (PWM) signal to the EC motor to control fan speed. The board is factory programmed
SECTION 233000 HVAC AIR DISTRIBUTION
1320 / Talent Community Center 233000-1 HVAC AIR DISTRIBUTION SECTION 233000 HVAC AIR DISTRIBUTION PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Ductwork. 2. Ductwork accessories. 3. Fans. 4. Air
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.
Application and esign Thermal ispersion Air Measuring Station with VC-23 Control amper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
How To Install A Perfect 16 Id Series Filter System
IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System Perfect 16 Installation Manual Product Data High-Performance Medical-Grade Residential/Commercial Air Filtration System Application The
Data Center Cooling. The engineer s choice
Data Center Cooling The engineer s choice About ebm-papst Inc. Headquarters - Farmington, CT» 250K sq. ft.» Acoustic testing chamber» Complete air testing lab on site» Mechanical/Design Engineering» Electrical
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
Bring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
CADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
MAC 10 LE-AC FAN FILTER MODULE INSTALLATION AND SERVICE MANUAL
*** READ AND SAVE THESE INSTRUCTIONS *** R MAC 10 LE-AC FAN FILTER MODULE INSTALLATION AND SERVICE MANUAL STANDARD, RSR, RSRE MODELS R R Mac 10 and VE5 are registered Trademarks of the Envirco, U.S.A.
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce
Vision Engravers and Routers PRE-Installation Guide. 2015 Vision Engraving & Routing Systems
Vision Engravers and Routers PRE-Installation Guide Revised: 8/19/2015 Vision Engravers and Routers PRE-Installation Guide All rights reserved. No parts of this work may be reproduced in any form or by
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
SINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010 1. Background Class II Type B Biosafety Cabinets (BSCs) are unique laboratory
Fresh Air Enclosure Cooling Filter Fans
763.576.3200 SPEC-00306 K763.422.2211 COOLING FRESH AIR ENCLOSURE COOLING FILTER FANS Fresh Air Enclosure Cooling Filter Fans TFP SIDE-MOUNT TFP10 215 CFM (365 m3/hr.) TFP6 140 CFM (238 m3/hr.) TFP4 55
Freezers - Ultrafreezers. Platilab & Irilab Series
Freezers - Ultrafreezers Platilab & Irilab Series PLATILAB: top security and performances with reliable temperature control. IRILAB: combining the high reliability of PLATILAB with the possibility to store
Operation and Installation Manual. Max Series
Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat
Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
LOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
AMD-33 Air Measuring Station with VCD-33 Control Damper
Application and esign Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB
SPECIFICATIONS CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB Page 1 Powerful VERTEX TM Complete Capture Design rivals the finest island hoods. Compact design allows the choice of many cooktop
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.
600KW - 1250KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control High capacity, 600-1250kw Dual voltage: 208-240/416-480vAC Digital load control, 5 kw
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF)
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF) PART 1-GENERAL 1.01 RELATED WORK SPECIFIED IN OTHER SECTIONS A. Electrical connections see electrical specifications. 1.02 SUBMITTALS A.
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS
PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
Technical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:[email protected] www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested
DOP Solutions Technical Document: Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested Issue 1: Prepared by Neil Stephenson and Tim Triggs and edited by
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions
LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions Description The LS-1 Series of tungsten halogen light sources are versatile, white-light lamps optimized for use in the
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL
LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL ENVIRCO Technical Support: 800-884-0002 Table of Contents WARNING... 3 INTRODUCTION... 3 FEATURES... 4 APPLICATIONS... 4 ASSEMBLY...
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous