RITTER Multiple Sonic Nozzle Calibration System
|
|
|
- Erick Bates
- 10 years ago
- Views:
Transcription
1 RITTER Multiple Sonic Nozzle Calibration System
2 »Wouldn t it be great to eliminate doubtful measurement results by using proven measurement technology? Providing the most precise results ensures and increases your ability to deliver highly accurate and sustainable knowledge about your work.«worldwide with the precision of the original!
3 Discovering the RITTER Multiple Sonic Nozzle Calibration System Operating Principle Cross section of Sonic Nozzle Sonic Nozzles and Critical Flow Venturis are constant volumetric flow measurement meters that can be used as a calibration standard for gas flow meters. Due to their high repeatability they are extremly precise. Sonic devices vary in size with an internal design of a nozzle consisting of a circular arc which leads to a minimum throat area with a smooth circular inlet. This design operates on the principle that as gas flows through the throat of the nozzle, the gas accelerates (Venturi effect) as it approaches the throat. As the differential pressure increases, the velocity at the throat, the minimum area, increases and the density decreases. When the velocity reaches the speed of sound (Mach 1), it is considered choked, sonic or critical. The Sonic Nozzle is operated by applying inlet pressure or using a vacuum to evacuating the exit to achieve an Inlet/Outlet pressure ratio of approx. 1.3 or greater. This ratio maintains the nozzle in a»choked«or»sonic«state. In this state, only the upstream pressure and temperature can influence the flowrate through the Nozzle. Nozzle flowrate becomes close to a linear function of the inlet pressure. Increasing the inlet pressure can increase the flow rate. One of the greatest advantages of Sonic Nozzles when compared to sub-sonic flowmeters is that downstream pressure disturbances cannot move upstream past the throat or sonic point of the Nozzle. Since throat velocity is higher and in the opposite direction of downstream disturbances, these pressure disturbances cannot move upstream past the throat or affect the velocity or the density of the flow through the Nozzle. Uncertainty levels of ±0.25% of reading or better can routinely be achieved since there are no moving parts. 0.8 Calibration Curve 0.6 Measurement Error Measurement Error [%] ,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 Flow Rate [ltr/h] Example of a calibration curve for a RITTER drum-type gas meter Nozzle diameter for 1 ltr/h: 0.03 mm - For your refenrence: Average diameter of human hair 0.07 mm
4 Features Sonic Nozzle measurement principle Calibration of gas volume flow and gas mass flow Calibration Certificates for nozzles by German National Primary Standard»PTB«Calibration uncertainty of nozzles 0.15% ~ 0.65% System calibration uncertainty 0.3% ~ 0.8% Long-term repeatability and accuracy from extreme sonic nozzle stability No retro-action from unit under test because of high pressure and»sonic«state Single & multi-point calibrations fully automated by PC & multi-lingual software Data storage to hard disc, export to MS-Excel, paper print of diagram and reports Computerized individual pneumatic valve control for each nozzle Specifications (for stated example below) 13 sonic nozzles Smallest nozzle: 1 ltr/h Largest nozzle: 15,000 ltr/h Flow rate range: 1 to 34,000 ltr/h Number of possible calibration flow rates with 13 nozzles: 8,191 (= ) Example of a RITTER Multiple Sonic Nozzle Calibration unit with 13 nozzles Standard equipment does not include drum-type meter as shown above
5 Installation Configurations There are two possible configurations for Sonic Nozzles: 1. Pressurized System 2. Vacuum System The RITTER system is designed to operate using the most common Pressurized System. It was decided against the alternate vacuum system, because it would draw from the meter being calibrated. This could introduce water or oil vapour of the Unit Under Test (UUT) into the calibration system causing disruption of the Sonic Nozzle design. A pressurized gas source like filtered lab air is used with a pressure regulator upstream of the Sonic Nozzle system. The measured process downstream can be at atmospheric pressure or greater as long as a minimum of 1.4 pressure ratio is maintained across the Nozzle. Using the pressure system approach, the Sonic Nozzle System will operate properly as designed, regardless of flow pulsations or fluctuations from the process downstream. The airflow range is directly related to the number and size of the installed nozzles as well as from the maximum pressure of the available air supply. Worldwide with the precision of the original! Pressure Temperature Compressor Pressure controller 1.6 bar P Valves Humidity V14 T H Nozzles 1 l 5 l 10 l 20 l 100l 50 l 100 l 200 l 500 l 1000 l 2000 l 5000 l l l Valves Schematic V1 V2 V3 V4 V5 V6 V7 V8 V9 V10 V11 V12 V13 Flow direction Pressure P Pulses Temperature Test device ( UUT ) Schematic view of the nozzle arrangement in a RITTER Multiple Sonic Nozzle Calibration System Equation for calculation of volume flow rate T V15 Valve Room conditions T ambient P RITTER Multiple Sonic Nozzle Calibration System Calibration service facilities that must maintain multiple types and sizes of meters, require the ability to calibrate a wide range of flow rates. RITTER wet test meters measure from 1 to 18,000 litres/hr. Dry gas meters can measure from 40 to 160,000 litres/hr. In order to extend the flow range beyond that of a single nozzle, the Sonic Calibration System can include multiple nozzles which can be installed in parallel. In the example arrangement shown in the schematic above, the installed 13 nozzles can be operated individually, in combination, or all together, providing the possibility of generating more than 8,000 different flow rates. With the number and sizes of those nozzles a total flow rate range of 1 litre/hour to approx. 35 m³/ hr can be achieved. Sonic nozzles offered are ASME and ISO certified. As with all RITTER products, the RIT- TER Multiple Sonic Nozzle Calibration System can be custom made to the requirements of the customer. Equation for calculation of mass flow rate 5mm 1mm Injection cone of Sonic Nozzle ltr/h Injection cone of Sonic Nozzle 1 ltr/h PTB certificates for all Sonic Nozzles of the RITTER Multiple Sonic Nozzle Calibration System Subject to alterations.
6 Dr.-Ing. RITTER Apparatebau GmbH & Co. KG Coloniastr D Bochum Germany Phone Fax Worldwide with the precision of the original!»the RITTER Multiple Sonic Nozzle Calibration System is an enormous help increasing and ensuring the knowledge about our measurement skills!« Rev
FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER
FLOW MEASUREMENT 200 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER Dr D G Stewart, NEL Dr M Reader-Harris, NEL Dr R J W Peters, McCrometer Inc INTRODUCTION The V-Cone
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
FORMATION DAMAGE AND WELL TREATMENT SYSTEM
FORMATION DAMAGE AND WELL TREATMENT SYSTEM FDWTS-10K Includes ability to test Liquid Permeability & Gas Permeability Fines migration & critical velocity Static Filtration Drilling mud invasion evaluation
Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any
Chapter 10 Flow Measurements Material from Theory and Design for Mechanical Measurements; Figliola, Third Edition Flow Rate Flow rate can be expressed in terms of volume flow rate (volume/time) or mass
Establishment of the Gas Flow Calibration Facility at CSIR-NPL, India
Establishment of the Gas Flow Calibration Facility at CSIR-PL, India Speaker: Shiv Kumar Jaiswal Fluid Flow Measurement Standards CSIR-ational Physical Laboratory (PLI) Dr. K.S. Krishnan Road ew Delhi
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
Flow System Calibration in Medical and Bio-medical Production Processes.
Flow System Calibration in Medical and Bio-medical Production Processes. Speaker / Author: Mark Finch Fluke Calibration Norfolk, Norwich, NR6 6JB, UK e-mail: [email protected] Phone: + 44 (0)1908 678
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
Testing methods applicable to refrigeration components and systems
Testing methods applicable to refrigeration components and systems Sylvain Quoilin (1)*, Cristian Cuevas (2), Vladut Teodorese (1), Vincent Lemort (1), Jules Hannay (1) and Jean Lebrun (1) (1) University
CO 2 41.2 MPa (abs) 20 C
comp_02 A CO 2 cartridge is used to propel a small rocket cart. Compressed CO 2, stored at a pressure of 41.2 MPa (abs) and a temperature of 20 C, is expanded through a smoothly contoured converging nozzle
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
Custody Transfer Measurement. with the V-Cone Flowmeter
Custody Transfer Measurement with the V-Cone Flowmeter Stephen A. Ifft McCrometer Inc. Hemet, California, USA Abstract This paper will discuss the approval of the McCrometer V-Cone flowmeter for custody
DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING
DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING Toshiharu Kagawa 1, Yukako Saisu 2, Riki Nishimura 3 and Chongho Youn 4 ABSTRACT In this paper, we developed a new laminar flow
191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES
191: Calibration and Standards in Measurement Richard Paton National Engineering Laboratory, Scotland, UK 1 General Principles 1 2 Gravimetric Calibration of Liquid meters 2 3 Volumetric Calibration of
The Fundamentals of Gas Flow Calibration
The Fundamentals of Gas Flow Calibration Application Note Introduction Understanding the fundamentals of gas flow calibration is essential for evaluating calibration systems, estimating the magnitude of
User s Manual Laminar Flow Elements
501:440-13 User s Manual Laminar Flow Elements 10920 Madison Avenue Cleveland, Ohio 44102 Tel: 216.281.1100 email:[email protected] Web:www.meriam.com 1 TABLE OF CONTENTS Subject Page Introduction... 3
Air Flow Optimization via a Venturi Type Air Restrictor
, July 3-5, 013, London, U.K. Air Flow Optimization via a Venturi Type Air Restrictor Anshul Singhal, Mallika Parveen, Member, IAENG Abstract The aim of this project is to create a flow restriction device
Advances in Thermal Dispersion Mass Flow Meter Accuracy
Advances in Thermal Dispersion Mass Flow Meter Accuracy By Dan McQueen President Fluid Components International (FCI) Advances in Thermal Dispersion Mass Flow Meter Accuracy By Dan McQueen President Fluid
Fiscal Measurement Natural Gas
White Paper FSG-WP-0012 February 2014 Fiscal Measurement Natural Gas Fiscal Measurement How much? Fiscal Measurement must not be confused with Custody Transfer; in fact, fiscal measurement is a more general
F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems
F ox W hi t e Paper Reduce Energy Costs and Enhance Emissions Monitoring Systems A Technical White Paper from Fox Thermal Instruments Rich Cada, VP Sales & Marketing, Fox Thermal Instruments, Inc. 399
8. ENERGY PERFORMANCE ASSESSMENT OF COMPRESSORS 8.1 Introduction
8. ENERGY PERFORMANCE ASSESSMENT OF COMPRESSORS 8.1 Introduction The compressed air system is not only an energy intensive utility but also one o the least energy eicient. Over a period o time, both perormance
Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article
F e a t u r e A r t i c l e Feature Article Development of a High Accuracy, Fast Response Mass Flow Module Utilizing Pressure Measurement with a Laminar Flow Element (Resistive Element) Criterion D200
Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy
Measurement & Analytics VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy ABB s VIS Multiphase Flow Meter Easy to operate, accurate and fieldproven
Fluid Mechanics Prof. S. K. Som Department of Mechanical Engineering Indian Institute of Technology, Kharagpur
Fluid Mechanics Prof. S. K. Som Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture - 20 Conservation Equations in Fluid Flow Part VIII Good morning. I welcome you all
4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.
CHAPTER 08 1. What is most likely to be the main driving force in pipe flow? A. Gravity B. A pressure gradient C. Vacuum 2.What is a general description of the flow rate in laminar flow? A. Small B. Large
Gas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Experiment 3 Pipe Friction
EML 316L Experiment 3 Pipe Friction Laboratory Manual Mechanical and Materials Engineering Department College of Engineering FLORIDA INTERNATIONAL UNIVERSITY Nomenclature Symbol Description Unit A cross-sectional
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter
www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding
Response of common flowmeters to unsteady flow
Response of common flowmeters to unsteady flow By Fredrik Laurantzon, Ramis Örlü, Nils Tillmark and P. Henrik Alfredsson CCGEx, KTH Mechanics, SE-1 44 Stockholm, Sweden Technical Report This report gives
AOE 3104 Aircraft Performance Problem Sheet 2 (ans) Find the Pressure ratio in a constant temperature atmosphere:
AOE 3104 Aircraft Performance Problem Sheet 2 (ans) 6. The atmosphere of Jupiter is essentially made up of hydrogen, H 2. For Hydrogen, the specific gas constant is 4157 Joules/(kg)(K). The acceleration
PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS
PORTER MASS MEASUREMENT AND CONTROL SYSTEMS PORTER: THE STANDARD OF EXCELLENCE IN MASS Porter Mass Flow products reflect nearly three decades of experience in the design and manufacture of precision instruments
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering
ME 239: Rocket Propulsion. Over- and Under-expanded Nozzles and Nozzle Configurations. J. M. Meyers, PhD
ME 239: Rocket Propulsion Over- and Under-expanded Nozzles and Nozzle Configurations J. M. Meyers, PhD 1 Over- and Underexpanded Nozzles Underexpanded Nozzle Discharges fluid at an exit pressure greater
Calibration of flow meters for liquids and gases
Calibration of flow meters for liquids and gases Testo Industrial Services More certainty, better service. www.testotis.com Flow rate calibration Calibration of flow meters Due to the requirements of a
A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW. 1998 ASME Fluids Engineering Division Summer Meeting
TELEDYNE HASTINGS TECHNICAL PAPERS INSTRUMENTS A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW Proceedings of FEDSM 98: June -5, 998, Washington, DC FEDSM98 49 ABSTRACT The pressure
ETC -SV. Class 0 oil-free compressed air through catalysis
Innovation QUALITy Reliability Worldwide ETC -SV Class 0 oil-free compressed air through catalysis The way to oil-free compressed air The ETC operating principle Through the process of catalytic oxidation,
www.kem-kueppers.com [email protected]
www.kem-kueppers.com [email protected] Calibration of flow meters according to DIN EN ISO/IEC 17025:2005 Introduction... 2 Calibration laboratory... 3 Description of the calibration process... 3 Calibration
Experiment # 3: Pipe Flow
ME 05 Mechanical Engineering Lab Page ME 05 Mechanical Engineering Laboratory Spring Quarter 00 Experiment # 3: Pipe Flow Objectives: a) Calibrate a pressure transducer and two different flowmeters (paddlewheel
Gas Flowmeter Calibrations with the Working Gas Flow Standard
Gas Flowmeter Calibrations with the Working Gas Flow Standard NIST Special Publication 50-80 John D. Wright, Jean-Philippe Kayl, Aaron N. Johnson, and Gina M. Kline November 3, 009 Fluid Metrology Group
AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL
FUEL CONSUMPTION MEASUREMENT AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL Description The combination of AVL Fuel Mass Flow Meter and AVL Fuel Temperature Control is a high precise and continuous
FLUID FLOW Introduction General Description
FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you
T U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
Fundamentals of Mass Flow Control
Fundamentals of Mass Flow Control Critical Terminology and Operation Principles for Gas and Liquid MFCs A mass flow controller (MFC) is a closed-loop device that sets, measures, and controls the flow of
THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT INTRODUCTION COEFFICIENT OF DISCHARGE
THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPERS THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT www.daniel.com INTRODUCTION Orifice meters are
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Dr. J. M. Meyers Dr. D. G. Fletcher Dr. Y. Dubief 1. Introduction Last lab you investigated flow loss in a pipe due to the roughness
A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS
Presented 2006 May 16-18 2006 ISFFM Queretaro, Mexico A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS P. Delajoud, M. Bair, C. Rombouts, M. Girard DH Instruments,
CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions
Mounting and operating instructions CONTOIL DFM 8EDM Table of contents Safety instructions 2 - Designed use - Installation, commissioning and operation - Operational safety - Return of the instruments
C. starting positive displacement pumps with the discharge valve closed.
KNOWLEDGE: K1.04 [3.4/3.6] P78 The possibility of water hammer in a liquid system is minimized by... A. maintaining temperature above the saturation temperature. B. starting centrifugal pumps with the
Rosemount Orifice Plate in Wet Gas
00870-0100-4810 January 2006 Page 1 Rosemount Orifice Plate in Wet Gas This paper discusses the phenomenon of wet gas measurement, definitions, and the need to accurately measure this mixture. This paper
Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com
PNEUMATIC PRODUCTS pneumaticproducts-spx.com Externally Heated Desiccant Compressed Air Dryers PHD Series PHD Series Dryers Reduce Purge Air Energy Costs PHD Series Dryers Reduce Purge Air Energy Costs
A basic introduction to steam
A basic introduction to steam FOR HOT, COLD, MOIST AND DRY, FOUR CHAMPIONS FIERCE. STRIVE HERE FOR MASTERY Milton 1666 Steam Wonderful Steam Very high heat content Recyclable Clean, non toxic Biodegradable
High Volume PM10/TSP Calibration/Verification/Audit Guidance. Issued: 12/15/14 - FINAL
High Volume PM10/TSP Calibration/Verification/Audit Guidance Issued: 12/15/14 - FINAL Purpose: The purpose of this guidance is to assist operators of industrial particulate samplers for particulate matter
UPM 15010. Figure 1 MPFM installed on well pad
UPM 151 In-line Multiphase Flowmeter Field Trial Comparison vs. Three Phase Flow Separator on Naturally Flowing Shale Wells A. Michael Jones, Independent Flow Measurement Consultant, Travis Gaskill, Daniel
MODEL TEG-F20. Specification Sheet. TEG-F20 Specification Sheet Ver. 2011-0310. Copyright(C) 2011 Tsukasa Sokken Co., Ltd.
Direct EGR Flow Meter MODEL TEG-F20 Specification Sheet TEG-F20 Specification Sheet Ver. 2011-0310 Copyright(C) 2011 Tsukasa Sokken Co., Ltd. 1. Overview Sokken model TEG series is an EGR Flow meter to
Stack Sampling Stack sampling or source sampling
Stack Monitoring Stack Sampling Stack sampling or source sampling may be defined as a method of collecting representative samples of pollutant laden air/gases at the place of origin of pollutants to determine
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPER Application of the Orifice Meter for Accurate Gas Flow Measurement www.daniel.com Summary
AN INSTRUMENT FOR GRAVIMETRIC CALIBRATION OF FLOW DEVICES WITH CORROSIVE GASES. J. O. Hylton C. J. Remenyik Oak Ridge National Laboratory *
AN INSTRUMENT FOR GRAVIMETRIC CALIBRATION OF FLOW DEVICES WITH CORROSIVE GASES J. O. Hylton C. J. Remenyik Oak Ridge National Laboratory * Paper prepared for the 4 th International Symposium on Fluid Flow
PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE
PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE APPLICATIONS NOTE FOR MEASUREMENTS AT THE ENTRANCE AND EXIT OF A THIRD STAGE SEPARATOR
Smart Electromagnetic Flowmeter Open channel Flowmeter Detector
Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow
ME 538: Experiment # 1 Flow measurement and particle generation instruments
ME 538: Experiment # 1 Flow measurement and particle generation instruments Suresh Dhaniyala Mechanical and Aeronautical Engineering Clarkson University Flow rate measurement Various types of flowmeters
Chapter 17. For the most part, we have limited our consideration so COMPRESSIBLE FLOW. Objectives
Chapter 17 COMPRESSIBLE FLOW For the most part, we have limited our consideration so far to flows for which density variations and thus compressibility effects are negligible. In this chapter we lift this
Variable V Area Flowmeter Rotameter The Original
Variable V Area Flowmeter Rotameter The Original 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com precise measurement of liquids
Computer Controlled Nozzle Performance Test Unit, with SCADA TFTC
Technical Teaching Equipment Computer Controlled Nozzle Performance Test Unit, with SCADA TFTC EDIBON SCADA System Teaching Technique used 1 Unit: TFTC. Nozzle Performance Test Unit 5 6 2 Control Interface
Daniel Venturi Tubes and Flow Nozzles Brochure
Daniel Venturi Tubes and Flow Nozzles Brochure Is unaccounted hydrocarbon draining your bottom line? When the stakes are high, any amount of unaccounted hydrocarbon drains the bottom line. That's why companies
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
Theory overview of flow measurement using differential pressure devices based on ISO-5167 standard.
Theory overview of flow measurement using differential pressure devices based on ISO-567 standard. rian FL40 flow computer description. Flow Cad software users manual. Technical note, Differential pressure
Energy and Flow Measurement for Hydronic Systems
Energy and Flow Measurement for Hydronic Systems Presented By: George Szyszko Applications Consultant MCR for ONICON Incorporated Why Measure Thermal Energy? To control something, you must first measure
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Precision Mass Flow Metering For CVD Applications.
Precision Mass Flow Metering For CVD Applications. Ir. H.J. Boer Research Department of Bronkhorst High-Tech B.V. Nijverheidsstraat 1A, 7261 AK Ruurlo The Netherlands. Tel: +31 (0)573 458800 Fax: +31 (0)573
Chapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
GOOD PRACTICE GUIDE THE CALIBRATION OF FLOW METERS
GOOD PRACTICE GUIDE THE CALIBRATION OF FLOW METERS www.tuvnel.com The calibration of flow meters This good practice guide covers the general principles of calibration when applied to the flow meters or
Fluid Flow Instrumentation
Fluid Flow Instrumentation In the physical world, mechanical engineers are frequently required to monitor or control the flow of various fluids through pipes, ducts and assorted vessels. This fluid can
Routinely surveying tower overhead vacuum systems can
Troubleshooting crude vacuum tower overhead ejector systems Use these guidelines to improve performance and product quality J. R. LINES AND L. L. FRENS, GRAHAM MANUFACTURING CO. INC., BATAVIA, NEW YORK
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2
Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2 Steve Baldwin Chevron Energy Technology Company Houston, Texas USA Casey Hodges CEESI Measurement Solutions. Nunn, Colorado
High Speed Aerodynamics Prof. K. P. Sinhamahapatra Department of Aerospace Engineering Indian Institute of Technology, Kharagpur
High Speed Aerodynamics Prof. K. P. Sinhamahapatra Department of Aerospace Engineering Indian Institute of Technology, Kharagpur Module No. # 01 Lecture No. # 06 One-dimensional Gas Dynamics (Contd.) We
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
ME 315 - Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS
ME 315 - Heat Transfer Laboratory Nomenclature Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS A heat exchange area, m 2 C max maximum specific heat rate, J/(s
CONTROL VALVE PRESSURE DROP AND SIZING
CONTENT Chapter Description Page I Purpose of Control Valve II Type and Main Components of Control Valve 3 III Power 5 IV. Pressure Drop Across Control Valve 7 V. Symbols and Units 10 VI. Unit Conversion
Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF
Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF Table of Contents Section 1 - General Introduction 1.1 1 Principles Of Operation 1.2 1 Reshaping The Velocity Profile
Achim Beisiegel Fouad El-Rharbaoui Michael Wich. AREVA GmbH, Technical Center, 63791 Karlstein, Seligenstädter Strasse 100, Germany
Achim Beisiegel Fouad El-Rharbaoui Michael Wich AREVA GmbH, Technical Center, 63791 Karlstein, Seligenstädter Strasse 100, Germany 1 Introduction AREVA GmbH operates a unique Thermal-hydraulic platform
Thermal environments. www.swema.com [email protected] Tel. +46 8 94 00 90
ISO 7730 Moderate Thermal Environments Thermal environments Swema equipment for the measurement of Moderate Thermal Environments is designed to comply with the standards: ISO7726 - Thermal environments
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method
G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires
How to measure absolute pressure using piezoresistive sensing elements
In sensor technology several different methods are used to measure pressure. It is usually differentiated between the measurement of relative, differential, and absolute pressure. The following article
Experiment (13): Flow channel
Introduction: An open channel is a duct in which the liquid flows with a free surface exposed to atmospheric pressure. Along the length of the duct, the pressure at the surface is therefore constant and
HOW TO SIZE A PRESSURE REGULATOR
CHOOSING THE CORRECT REGULATOR HOW TO SIZE A PRESSURE REGULATOR In order to choose the correct regulator the following information is needed: - Function: Pressure reducing or backpressure control? - Pressure:
G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method
G4 ICARUS HF Simultaneous Determination of Carbon and Sulfur in Solids Innovation with Integrity Combustion Method High Performance Carbon & Sulfur Analyzer Combustion Method with High-Frequency Furnace
Flow Measurement Options for Pipeline and Open Channel Flow
Flow Measurement Options for Pipeline and Open Channel Flow October 2013 Presented by Molly Skorpik - 2013 Montana Association of Dam and Canal Systems Conference Irrigation Training and Research Center
Technical & Sizing Bulletin for Meriam LFEs. Laminar Flow Elements
Technical & Sizing Bulletin for Meriam LFEs Laminar Flow Elements What they are... Meriam Laminar Flow Elements are gas volume rate of flow differential producers operating on capillary flow principles.
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS J J Brasz, Carrier Corporation, Syracuse, NY, 13221, USA [email protected] I K Smith and N Stosic
THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT
THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT Kazuto Otakane, Tokyo Gas Co., Ltd Katsuhito Sakai, Tokyo Gas Co., Ltd Minoru Seto, Tokyo Gas Co., Ltd 1. INTRODUCTION Tokyo Gas s new gas meter,
Radial piston pumps type R and RG
Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).
HYDRAULIC MACHINES Used to convert between hydraulic and mechanical energies. Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic
How To Use A Corona Mdi 110
CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output
Ultrasonic Gas Meters for Industrial and Commercial Applications. Ohio Gas Association Technical Seminar March 27-28,2014
Ultrasonic Gas Meters for Industrial and Commercial Applications Ohio Gas Association Technical Seminar March 27-28,2014 Objectives Technology Operation Benefits Applications Approvals and Standards Products
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically