1 NEUDORFER ENGINEERS, INC. provides our customer with unbiased, professional, performance testing of Cleanrooms. We are committed to providing you, our customer, with value-added expertise in an effort to ensure the best possible performance for your facility. Our staff can test and certify a Cleanroom to either Federal Standard 209E or International Standard Organization (ISO) requirements. We have the instrumentation and experienced personnel to certify everything from a Class 1 Cleanroom at 0.1 micrometers, to a Class 100,000 Cleanroom at 5.0 micrometers. CLEANROOM TESTING & CERTIFICATION Neudorfer Engineers specializes in the testing and certification of Cleanrooms. Our field engineers perform Cleanroom certification procedures in accordance with NEBB standards, IEST recommended practices, ISO standards, owner specifications, and our company s internal procedural standards. We can perform this testing in your Cleanroom, laminar flow work stations and benches, fume hoods, biological safety cabinets or any other environment that you may need tested for viable particle counts and bioburden testing. Each of our clients has unique requirements; therefore, each of our testing plans is individually tailored to their specifications. Listed below are the most common test specifications in use around the world. ISO and ISO : The ISO standards are recognized as the international Cleanroom standards. These standards are similar in scope and requirements to the retired Federal Standard 209E. The ISO standards are metric classification only, and the particle count limits and room classifications do differ from Federal Standard 209E. The United States Government has adopted the ISO standards and has phased out FS 290E. Federal Standard 209E: This is by far the most commonly referenced test standard in use today. This standard was retired in December of 2002 and is no longer a United States Federal Standard, although, the FDA has acknowledged that the fundamentals are sound and should be part of a Good Manufacturing Practice (GMP). The United States Government has adopted the ISO standards, although when Federal Standard 209E was in effect the standard provided for standardized classifications for airborne particle count levels in clean environments. This standard does not specify other environmental parameters that may be required, such as air velocity, room pressures, furniture, or room furnishing specifications, etc. NEBB Procedural Standards: (Procedural Standards for Certified Testing of Cleanrooms, 1996 Edition) These comprehensive testing standards cover most environmental parameters. These standards expands the other standards and gives the certifiers a practical how to insight into certification. Page 1 of 5
2 IES RP-CC : This test standard provides test procedures for most environmental parameters that may be required. Some of these procedures include filter integrity testing, room pressurization, temperature and relative humidity, and room recovery testing, to name a few. IES RP-CC : This recommended practice document covers the procedures for leak testing HEPA and ULPA filters. User Specified Limits: It is very common for the Cleanroom owner or contractor to create an in-house test standard that may include aspects from all three standards listed above. We are able to assist the user in the development of a comprehensive test standard that will provide a reasonable applicable test specification. The table below describes the most common Cleanroom performance tests that we perform, and specifies the common room condition in which the test(s) are performed. Test Procedure Unidirectional Airflow Room Supply Volume 1,2,3 1,2,3 Filter Leak Test 1,2 1,2 Airborne Particle Count 1,2 1,2 Non-Unidirectional Airflow Room Comments This test may be performed with a velocity meter or flow hood. Using an aerosol challenge of PAO or PSL, depending on product sensitivity. Performed with an airborne particle counter with size sensitivity suitable for room classification. Room Pressurization 1,2,3 1,2,3 Using digital micro- manometer. Room Airflow Uniformity 1,2 1,2 Room Recovery Test 1,2 1,2 Particle Fallout Test 1,2,3 1,2,3 Room Lighting Level 1,2,3 1,2,3 Room Noise Level 1,2,3 1,2,3 Temperature & Humidity 1,2,3 1,2,3 Using dry ice fogger and visual, still photo, or video tape recording. Using particle generator and airborne particle counter. Using fallout plate monitors at critical locations. Using digital photometer, per IES handbook. Generally performed for contractual compliance or safety requirements. Taken at each particle count location or long-term trend study, as required. Vibration Level 1,2,3 1,2,3 Generally performed for contractual li f i Page 2 of 5
3 compliance or safety requirements. Bioburden Test 1,2,3 1,2,3 Using RCS samplers, contract plates, or fallout plates. 1. Indicates the test is best performed in an as-built condition. 2. Indicates the test is best performed in an at-rest condition. 3. Indicates the test is best performed in an operational condition. The table above reflects the most common testing performed on Cleanrooms. Cleanroom Performance Testing: Neudorfer Engineers, Inc. provides our customer with unbiased, professional, performance testing of Cleanrooms. We are committed to providing you, our customer, with value-added expertise in an effort to ensure the best possible performance for your facility. Our staff can test and certify a Cleanroom to either Federal Standard 209E or International Standard Organization (ISO) requirements. We have the instrumentation and experienced personnel to certify everything from a Class 1 Cleanroom at 0.1 micrometers, to a Class 100,000 Cleanroom at 5.0 micrometers. Performance testing can be done at three different levels of operation: as-built, at-rest and operational. In the as-built condition, the room is complete, with no equipment or personnel present. In the at-rest condition, the equipment is in the room, but not running, and there are no personnel present. In the operational condition, the room is operational, with equipment running and personnel present. The only performance testing required certifying a Cleanroom by either standard is ambient particle counts, which determine the cleanliness of the area. We, however, recommend additional tests for a more in-depth understanding of the Cleanroom. These additional tests include filters scan, pressurization, airflow velocity and uniformity, airflow parallelism, temperature and relative humidity, floor conductivity, and sound and lighting testing. Each of these tests will give you a better understanding of the environment of your facility. The filter scan test is designed to ensure that the ceiling system is installed correctly and that there are no leaks in the filter media or ceiling grid. A polystyrene test confirms that this is true. The Cleanroom should be at a higher pressure than the surrounding, less- clean areas in order to prevent contamination from entering the Cleanroom. The pressurization test confirms that this is true. The airflow test is done to determine the velocity and uniformity of airflow through the clean space. The airflow through each filter is measured and adjusted, as necessary, so that the air entering the room is within specifications. It sometimes is necessary to run laminar airflow and airflow parallelism tests to prove this. Page 3 of 5
4 The temperature and relative humidity are measured over time to determine if the air handlers in the area are able to establish and maintain uniformity. It is necessary in a Cleanroom to avoid build-up of static electric energy. We can measure the resistance of the floor, both point-to-point and point-to-ground, to determine if the floor system meets the design criteria. Noise level testing is used to measure the sound levels present in the Cleanrooms. Sound levels are compared to Noise Criteria (NC) Curves as a way of quantifying the actual levels to predetermined industry standards. The more noise sensitive the usage of a room, the lower the required NC level. Light levels are measured to determine the amount of light at the working height in the Cleanroom. (The first half of this paragraph is duplication of earlier copy.) (The page needs a title.) Our company specializes in the testing and certification of Cleanrooms. Trained technicians perform Cleanroom certification procedures in accordance with NEBB standards, IEST-recommended practices, ISO standards, owner specifications, and our own procedural standards. The company has developed a certification program that offers customized performance evaluations, including precision filter integrity, testing using a fully computerized robotic scan, and a filter challenge using PSL spheres. Test data is presented through field and office CAD Systems. As a certified member of the National Environmental Balance Bureau (NEBB) and a member of the Institute of Environmental Science and Technology (IEST), we work at home in the Pacific Northwest and around the world. We can help you get your facility certified, providing professional service and long-term solutions to any problem we come across, rather than quick, easy, short-term fixes. Air Balance and Adjustment: If we determine during testing that air balance or system adjustments are required to meet your contamination control requirements, we are often able to perform these adjustments ourselves, saving you time and money. HEPA Filter Repair/Replacement: We can repair most damage we find during our filter leak testing. When there is no problem that requires filter replacement, we can perform this for you without major delay. We are able to provide bioburden (viable particle count) testing at the same time as we perform a normal Cleanroom test and certification. We use RCS samplers and contact plates to collect viable samples from various locations in your Cleanroom. The samples are then incubated in our contamination lab and the total viable particles are counted and reported to you. Cleanroom Testing & Certification: We can verify requisite standards in biological or microelectronic facilities for Cleanroom testing and certification ranges, from spot testing to reviewing specifications, creation of test and certification procedures for the FAB, and the deployment of test services. Page 4 of 5
5 We offer standard tests for certification of a Cleanroom during the commissioning and through full operation for charge, damage or failure of the environment s system components, and quality assurance. Among tests conducted for Cleanroom certification are: Room pressurization testing to verify capabilities of the Cleanrooms air handler Airborne particle count test to compare Cleanroom classification level to cleanliness HEPA/ULPA filter leak scan to determine the integrity of the installed Cleanroom system Ultra Violet (UV) light wave spectrum analysis designed specifically for measuring light within a semiconductor lithography processing area. Page 5 of 5
PROCEDURAL STANDARDS FOR CERTIFIED TESTING OF CLEANROOMS
PROCEDURAL STANDARDS FOR CERTIFIED TESTING OF CLEANROOMS 2009 THIRD EDITION National Environmental Balancing Bureau 8575 Grovemont Circle Gaithersburg, Maryland 20877 301-977-3698 301-977-9589 FAX www.nebb.org
ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS
ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS PRESENTATION TO RACI 20 TH APRIL 2016 PAUL MORGAN DIRECTOR CRITICAL CERTIFICATION PTY LTD CHANGES TO ISO14644 PART 1 CHANGES
FS209E and ISO Cleanroom Standards
FS209E and ISO Cleanroom Standards Terra Universal is the leading expert in the design and fabrication of critical-environment applications. We offer a complete range of equipment, furnishing and supplies
CLEAN ROOM MONITORING REGULATORY STANDARDS
CLEAN ROOM MONITORING REGULATORY STANDARDS Air Classification as per Schedule M Maximum permitted number of particles / m3 equal or above at rest in operation 0.5µm 5.0µm 0.5µm 5.0µm A 3,520 29 3,500 29
Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.
Product Sampler #1 Laminar Flow Hoods / Laminar Flow Cabinets: 1- Benchtop Vertical Laminar Flow Hoods- Air Recirculation Available s: Clean Bench Class 100 Bench-top Vertical Laminar Flow Hoods with Air-recirculation
EU GMP Annex 1 Update 2008: Airborne Particle Counting
EU GMP Annex 1 Update 2008: Airborne Particle Counting Airborne Particle Counting for Pharmaceutical Facilities: Update 2008, EU GMP Annex 1 Morgan Polen - VP of Applications Technology, Lighthouse Worldwide
Environmental Monitoring of Clean Rooms
Environmental Monitoring of Raul Duarte President DDK Scientific, Corp. Copyright DDK Scientific, Corp. 2008, 2009, DDK Scientific, Corp. Proprietary A manufacturing facility for pharmaceutical products
Environmental Monitoring
Chapter 10 Environmental Monitoring By the end of this chapter, you will be able to: l List the types of environmental testing l Name three types of checks that are carried out to ensure the isolator is
Particle Monitoring Requirements in Pharmaceutical Cleanrooms
Particle Monitoring Requirements in Pharmaceutical Cleanrooms All drugs must be manufactured in accordance with the current Good Manufacturing Practice (cgmp) regulations. Pharmaceutical manufacturers
G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice
G U National Air Filtration Association Recommended Practice I D E L I N E Procurement Guideline TRAINING EDUCATION CERTIFICATION HVAC Air Filter Purchasing Specification Guideline 1.0 Purpose To provide
Environmental Monitoring
Environmental Monitoring Purpose of Environmental Monitoring Critical process within the pharmaceutical and biotechnology industries. Determines the microbial and particulate content of cleanroom air and
CLASSIFICATION OF CLEANROOMS
CLASSIFICATION OF CLEANROOMS Cleanrooms are classified by the cleanliness of their air. The method most easily understood and most universally applied is the one suggested in the earlier versions (A to
USP <797> Cleanroom Design and Environmental Monitoring. Andrew King, USP <797> Specialist CETA Member RCCP-SC
USP Cleanroom Design and Environmental Monitoring Andrew King, USP Specialist CETA Member RCCP-SC Objectives The objectives of this presentation: To summarize basic cleanroom concepts and how
Manufacturing. Environmental Monitoring Particle Counts Are Easy B IOP ROCESSTECHNICAL. Scott E. Mackler
B IOP ROCESSTECHNICAL Environmental Monitoring Particle Counts Are Easy Scott E. Mackler Manufacturing pharmaceutical and biotechnology products requires that the appropriate level of quality be designed
International Standard ISO 14644
International Standard ISO 14644 Cleanrooms and associated controlled environments Praphon Angtrakool Food and Drug Administration 1 International Standard : ISO 14644 ISO 14644 consists of the following
NEBB Cleanroom Performance Testing Certified Professional Seminar and Exams
NEBB Cleanroom Performance Testing Certified Professional Seminar and Exams October 20-22, 2014 Orlando, FL Introduction Cleanroom testing must be performed to ensure that cleanrooms comply with design
GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS
PHARMACEUTICAL INSPECTION CONVENTION PHARMACEUTICAL INSPECTION CO-OPERATION SCHEME PI 032-2 8 January 2010 RECOMMENDATION GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE
Validating and Monitoring the Cleanroom
6 Validating and Monitoring the Cleanroom Kevina O Donoghue Overview... 6-1 Cleanroom Design... 6-1 Principles of Cleanroom Validation and Testing... 6-2 Cleanroom Validation... 6-2 So How Does One Determine
APPENDIX A-1 SAMPLE CLEANROOM SPECIFICATIONS MICROELECTRONICS & SEMICONDUCTORS
APPENDIX A-1 SAMPLE CLEANROOM SPECIFICATIONS SECTION xxxxx CLEANROOM PERFORMANCE TESTING PART 1 -- GENERAL 1.1 WORK INCLUDED A. This Section specifies the requirements of the NEBB Certified Cleanroom Performance
Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested
DOP Solutions Technical Document: Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested Issue 1: Prepared by Neil Stephenson and Tim Triggs and edited by
EACO DOP / PAO TESTING GUIDELINE 2013
2013 Foreword The guideline promotes industry standards for training, equipment, and methodologies for HEPA filter integrity testing of negative air units, vacuums and any other HEPA filtered equipment
Approval Block. Prepared by: Signature Date. Evan Parnell 08 NOV 2013. Reviewed by: Signature Date. Approved by: Signature Date
ATS-ATP-3460 Page: 1 of 5 Approval Block Prepared by: Signature Date Evan Parnell 08 NOV 2013 Reviewed by: Signature Date Brian Flynn 08 NOV 2013 Approved by: Signature Date Kristal Jewell 08 NOV 2013
Class II, Type A2 Biological Safety Cabinet HEPA Filter Loading Capacity
Class II, Type A2 Biological Safety Cabinet HEPA Filter Loading Capacity Best Products. Best Performance. Best Protection. NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A ph: 763.553.1270 fx:
Raleigh, NC May 12 th & 13 th 2016. Meeting The New ISO Cleanroom Standards And Changing EU Guidance How Will You Comply?
Raleigh, NC May 12 th & 13 th 2016 Meeting The New ISO Cleanroom Standards And Changing EU Guidance How Will You Comply? The International Cleanroom Standards (ISO 14644-1 & 2) have been updated, these
Regulations Concerning
Regulations Concerning Airborne Particle Counting Two types of activities performed with an airborne particle counter: Classification focuses primarily on the environment Particle Counting Applications
Laminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
Smoke Studies: Clearing the Mystery of Air Flow Visualization
Ed White, Coordinator] Smoke Studies: Clearing the Mystery of Air Flow Visualization Steven Klingenberg The Aseptic Core discusses scientific and regulatory considerations for aseptic processing, with
Risk-Based Environmental Monitoring. Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI
Risk-Based Environmental Monitoring Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI Presenter Marsha Stabler Hardiman Over 20 years experience in the
CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS
CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS UNDERSTANDING, ACCELERATED TSI SETS THE STANDARD FOR PARTICLE COUNTING Performance Semiconductor, hard disk drive, and flat panel manufacturers
ISO 21501 A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners
ISO 21501 A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners Tony Harrison and Bob Latimer ISO 21501- A Standard Methodology to Optical Particle Counter
ENVIRONMENTAL MONITORING
ENVIRONMENTAL MONITORING Assessment and verification of the adequacy of the aseptic compounding environment is essential. Environmental monitoring programs are designed to promptly identify potential sources
HEPA Filters for Pharma Applications Cleanrooms & Safety Applications. Gordon Farquharson June 2012
HEPA Filters for Pharma Applications Cleanrooms & Safety Applications Gordon Farquharson June 2012 1 Air Filters at work Images courtesy of CamfilFarr 2 How filters work Sieving Effect Straining 3 Filter
Everything you want to know about USP 797
Everything you want to know about USP 797 Dr. Linda D. Lee Director of Operations Waste Management Healthcare Solutions September. 22, 2009 Goals High level understanding of USP 797 Who does it apply too
Contamination Control and Environmental Monitoring Systems
Life Science Contamination Control and Environmental Monitoring Systems Hospital Electronics Brookhaven Instruments deliver, install and validate particle counters, Microbial Air Samplers and Monitoring
Laminar Flow Hoods and Booths
Laminar Flow Hoods and Booths ... we go further... to absolutely clean air! Klimaoprema Cleanroom Technology is a leading Croatian manufacturer of equipment for cleanrooms. We offer complete engineering
LAMINAR FLOW CABINETS
LAMINAR FLOW CABINETS Vertical Laminar Flow Cabinets VLF 550 VLF650 VLF1000 VLF1200 VLF 1500 VLF1800 Monmouth Scientific's brand new range of Vertical laminar Flow (VLF) cabinets is available in six different
www.dataspan.com 800.660.3586 Data Center and Computer Room Services Specialty Services Data Center and Computer Room Products Sub-Floor Cleaning
Data Center Cleaning Services The best way to eliminate downtime? Stop problems before they start. Our specialized anti-static cleaning services will protect your storage media and other important infrastructure
HVAC Air Systems. Recirculation Air System Types
HVAC Air Systems Recirculation Air System Types Summary Recirculation air handler fan energy can account for 10 to 30% of total cleanroom energy use. There are three fundamental recirculation system configurations:
Performance Evaluation of Cleanroom Environmental Systems. Biography. Abstract. Keywords. Introduction
Performance Evaluation of Cleanroom Environmental Systems Tengfang Xu, Lawrence Berkeley National Laboratory Biography Tengfang Xu is a Project Manager currently with the Environmental Energy Technologies
GUIDELINES ON TEST METHODS FOR ENVIRONMENTAL MONITORING FOR ASEPTIC DISPENSING FACILITIES
GUIDELINES ON TEST METHODS FOR ENVIRONMENTAL MONITORING FOR ASEPTIC DISPENSING FACILITIES PRODUCED BY A WORKING GROUP OF THE SCOTTISH QUALITY ASSURANCE SPECIALIST INTEREST GROUP SECOND EDITION FEBRUARY
MOHD NASRUL MOHAMAD NOOR
QUALITY ASSURANCE IN ASEPTIC WHO Collaborating Centre For Regulatory Control of Pharmaceuticals DISPENSING : MAINTENANCE OF CLEAN ROOM & EQUIPMENT Member of Pharmaceutical Inspection Cooperation Scheme
Qualification of Cleanrooms and Environmental Monitoring - Practical Approaches in Europe
Qualification of Cleanrooms and Environmental Monitoring - Practical Approaches in Europe 1 Dr. Doris Herrmann Zum Eselsbachtal 20 67657 Kaiserslautern [email protected] www.gmp-unlimited.com
Filter Fan Unit Systems. Cleanroom Products
Filter Fan Unit Systems Cleanroom Products Experience matters... with Filter Fan Units from M+W Products M+W Products has been a pioneer in filter fan unit systems since 1990. During that period more than
Testing HEPA/ULPA filters at the manufacturer s facility and in situ on the user s premises
Publication Series Viledon Testing HEPA/ULPA filters at the manufacturer s facility and in situ on the user s premises Dipl.-Ing. Thomas Schroth Dr.-Ing. Thomas Caesar Lecture at 4th CLEANROOMS Europe
Design, Construction, Commission, and Qualification of Critical Utility Systems: Part III
Design, Construction, Commission, and Qualification of Critical Utility Systems: Part III BY DAVID W. VINCENT AND HERBERT MATHESON HEATING, VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEMS INTRODUCTION
PERFORMANCE QUALIFICATION OF A CLEAN ROOM FROM A QUALITY PERSPECTIVE
PERFORMANCE QUALIFICATION OF A CLEAN ROOM FROM A QUALITY PERSPECTIVE Every facility design is unique for its specific needs, and validation programs must be customized to meet these challenges. While there
Indoor air quality monitoring made easy
Indoor air quality monitoring made easy with the Fluke 985 Particle Counter Application Note Introduction Energy savings is top of facilities owners agenda. HVAC system tends to be the largest contributor
Particle Counting and Environmental Monitoring In Pharmaceutical / Life Sciences
Particle Counting and Environmental Monitoring In Pharmaceutical / Life Sciences LIGHTHOUSE WORLDWIDE SOLUTIONS WWW.GOLIGHTHOUSE.COM Introduction The pharmaceutical and medical device industries are developing
Laminar Flow Cabinets and Workstations
VERTICAL AND HORIZONTAL HEPA FILTERED SYSTEMS FOR PROCESS OR OPERATOR PROTECTION Laminar Flow Cabinets and Workstations For procedures requiring protection from particulate contamination and for aseptic
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010 1. Background Class II Type B Biosafety Cabinets (BSCs) are unique laboratory
High Efficiency Particulate Air (HEPA) Filter Velocity Reduction Study
High Efficiency Particulate Air (HEPA) Filter Velocity Reduction Study International SEMATECH Manufacturing Initiative Advanced Materials Research Center, AMRC, International SEMATECH Manufacturing Initiative,
Cleanroom Solutions Ltd T: 01273 760 060 F: 01273 760 061 E: [email protected] W: www.cleanroom-solutions.co.uk
Cleanroom Solutions Ltd T: 01273 760 060 F: 01273 760 061 E: [email protected] W: Introduction Cleanroom Solutions Ltd has a wealth of experience together with a solid track record in the
Spetec. Clean room. technology. Laminar flow box Clean room workbench CleanBoy Clean room cell Service, certification
Spetec Clean room technology Laminar flow box Clean room workbench CleanBoy Clean room cell Service, certification 1 Product overview PBS, FMS, and FBS series device families feature a modular design,
cleanroom validation Cleanroom Validation
Cleanroom Validation cleanroom applications laboratories production environments laminar flow boxes cleanroom concepts microelectronics pharmaceutical industry, food industry nuclear industry, aerospace
Data Center Cleaning Services Rev. 0 Bid #47297114. Scope of Work
Scope of Work I. Scope of Solicitation II. Instructions to Offerors III. Scope of Work / Specifications IV. Terms and Conditions - Special V. Appendices to Scope of Work VI. Bidding Schedule I. SCOPE OF
HVAC Design Requirements
Maintenance of HVAC HVAC Design Requirements Air Flow Diagram แบบ Recirculation Air Flow Diagram แบบ Once Through Definition Of Conditions As built At rest In operation air air air Maintenance GMP Requirements
Understanding USP 797
DDK Scientific, Corp. Raul Duarte June 2008 Copyright DDK Scientific, Corp. 2008, 2009 DDK Scientific, Corp. Proprietary The purpose of USP 797 is to prevent harm and fatality to patients that could result
Hazardous Drug. Cleanroom. Standards
Hazardous Drug Cleanroom Standards Module 3 Table of Contents Section A... 1 A.1 International Standards Organization (ISO) Classifications... 1 A.2 Hazardous Drug Cleanroom and Anteroom... 1 A.2.1 Location
Specifying Laser Scanning Services. A Quantapoint White Paper
A Quantapoint White Paper ABSTRACT Specifying Laser Scanning Services to Help Ensure Trusted and Accurate Results As-built documentation created using laser scanning is rapidly being adopted as the tool
SPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
HEPA Filters and Filter Testing A Comparison of Factory Tests and In-Service Tests Bulletin: PB2007-0504
HEPA Filters and Filter Testing A Comparison of Factory Tests and In-Service Tests Bulletin: PB2007-0504 Introduction HEPA filters, once known as absolute filters, were originally developed as the particulate
The use of risk assessment tools for microbiological assessment of cleanroom environments. by Tim Sandle
The use of risk assessment tools for microbiological assessment of cleanroom environments by Tim Sandle Email: [email protected] / [email protected] Web: www.pharmig.blogspot.com Environmental
Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
What to Know When Considering a Cleanroom. by Simplex Technical Staff
What to Know When Considering a Cleanroom by Simplex Technical Staff What to Know When Considering a Cleanroom by Simplex Technical Staff Does your business plan include the development of an area in your
VAV Laboratory Room Airflow The Lowdown on Turndown
Technology Report March, 2003 VAV Laboratory The Lowdown on Turndown Turndown comparison of these two turndown ratios. Note the small actual airflow difference between them. control ranges are normally
Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health
Background Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health This document provides guidelines for the design and installation of Class
Design, Operation and Management of GTP/GMP Cell Engineering Facilities
Design, Operation and Management of GTP/GMP Cell Engineering Facilities Scott R. Burger, MD Advanced Cell & Gene Therapy BFDA 2007 International Symposium on Regulation of Human Cell and Tissue- Based
VALIDATION OF CLEAN ROOMS FOR ASEPTIC MANUFACTURING. F.R.Smal Pharmaceutical Director ICCE ICCE a member of SNC-Lavalin Group
VALIDATION OF CLEAN ROOMS FOR ASEPTIC MANUFACTURING F.R.Smal Pharmaceutical Director ICCE ICCE a member of SNC-Lavalin Group tel + 3226431600 E-Mail: [email protected] VALIDATION OF CLEAN
Spetec. Laminar Flow Box. Portable Clean Room Technology
Spetec Laminar Flow Box Portable Clean Room Technology 1 Fundamentals Portable Clean Room Technology Laminar Flow The basis for the development of the clean room technology was first established in the
Welkom! Filter Test Seminar. WiFi: Lighthouse Public, Paswoord: 1234567890
Welkom! Filter Test Seminar WiFi: Lighthouse Public, Paswoord: 1234567890 www.golighthouse.nl 1 Huishoudelijke aard: Toilet Nooduitgang GSM Foto s 1 e verdieping en Beneden bij entree trap voor en achter
A Basic Design Guide for Clean Room Applications
PDHonline Course M143 (4 PDH) A Basic Design Guide for Clean Room Applications Instructor: A. Bhatia, B.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088
BIOLOGICAL SAFETY CABINET PROGRAM
BIOLOGICAL SAFETY CABINET PROGRAM TABLE OF CONTENTS: 1. INTRODUCTION 2. PURPOSE AND SCOPE 3. SELECTION AND INSTALLATION 4. USE OF BIOLOGICAL SAFETY CABINETS 5. CERTIFICATION OF BIOLOGICAL SAFETY CABINETS
TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS
TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS APPLICATION NOTE CC-105 (US) Introduction This application note will demonstrate how real-time viable particle count data will
and Drug Administration/Office of Regulatory Affairs (FDA/ORA) laboratories.
Page 1 of 13 Sections Included in this Document and Change History 1. Purpose 2. Scope 3. Responsibilities 4. Background 5. References 6. Procedure/(6.C.4. added or electronically ) 7. Definitions 8. Records
Viledon HEPA and ULPA Filters The Patented Solution for Sterile Air and Clean Rooms. Product Overview
Viledon HEPA and ULPA Filters The Patented Solution for Sterile Air and Clean Rooms Product Overview In a class of their own for technology and performance While the performance qualities of air filters
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
DISCUSSION TOOL PRESENTED TO THE AABB CT REGULATORY AFFAIRS SUBSECTION
1 US FDA Form 483: A Case Study DISCUSSION TOOL PRESENTED TO THE AABB CT REGULATORY AFFAIRS SUBSECTION DEVELOPED BY FRAN RABE 2 Introduction This case study is intended to extract portions of information
DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS
DATA CENTERS Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS COSTLY FAN ENERGY REDUCED BY CAMFIL PREMIUM PRODUCTS = COST SAVINGS Power Usage Effectiveness (PUE) is an important metric
Risk Assessment: Biosafety Cabinet
Risk Assessment: Biosafety Cabinet Biosafety cabinets (BSCs) serve as primary containment devices for operations involving potential splashes, spills or aerosolization of hazardous biological materials.
Shakers, Incubators, Clean Benches, Water Baths, Drying Ovens
Shakers, Incubators, Clean Benches, Water Baths, Drying Ovens Ask for catalogues and brochures Learn distribution terms and conditions Download brochures and leaflets Register for monthly newsletters Check
Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories
Esco Labculture Laminar Flow Clean Bench Model LHC-4A_ AS 1386.5, EN12469 (Microbiological Testing Method) Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories
Procedures for the Effective Use of Biological Safety Cabinets
Procedures for the Effective Use of Biological Safety Cabinets APPROVAL DATE BY BIOHAZARDS SUBCOMMITTEE: August 10, 2012 SUPERSEDES: March 1, 2012 This corporate guideline/procedure is intended as a minimum
FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.
Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. Vertical Laminar Flow Cabinets BEYOND MINIMUM SAFETY REQUIREMENT Cabinets are ISO Class 3 vertical laminar flow cabinets which
DRAFT GUIDANCE. This guidance document is being distributed for comment purposes only.
Guidance for Industry Current Good Manufacturing Practice Interim Guidance for Human Drug Compounding Outsourcing Facilities Under Section 503B of the FD&C Act DRAFT GUIDANCE This guidance document is
Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories
Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories Esco Airstream Laminar Flow Clean Bench Model AHC-4D_ Esco Experience Esco is the world leader in premium
Question and Answer Guide for
Question and Answer Guide for FIRE DAMAGE Are you wondering: if we will be able to get the smoke smell out? if we will do all of the cleaning and repairs? or are you wondering if you need to do anything?
How to Measure HVAC System Airflow
How to Measure HVAC System Airflow About National Comfort Institute National Comfort Institute is an international training Since our and beginning development in 1994 company we have trained with and
Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9
Chapter 9 By the end of this chapter, you will be able to: l Define the terms cleaning, decontamination, disinfection l List the factors that affect disinfection l Describe the aims of a cleaning schedule
Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations
Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations B e c k m a n C o u l t e r L i f e S c i e n c e s 2 5 0 S. K r a e m e r B o u l e
HEPA Filters and Filter Testing A Comparison of Factory Tests and In-Service Tests
FOREMOST IN AIR FILTRATION HEPA Filters and Filter Testing PB-2007-1203 HEPA Filters and Filter Testing A Comparison of Factory Tests and In-Service Tests A Wholly Owned Subsidiary of Flanders Corporation
Information. Cleanroom Product Range-subjected to change
Cleanroom Product Range-subjected to change 123 General information Introduction to Cleanroom The term Cleanroom is something you associate with in modern industries. However, the root of cleanroom design
CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications
1 CO2 Incubator Model CCL-170_-_ CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications Welcome to Esco Esco s Vision is to provide enabling technologies for scientific
Cleanroom Design and Operations
Cleanroom Design and Operations Philip J Denny USPAS Course: SRF Technology: Cleanroom Design and Operations January 2015 P. Denny Topics Introduction Contamination Design Operation Monitoring Protocols,
SECTION 15950 - TESTING, ADJUSTING, AND BALANCING
SECTION 15950 - TESTING, ADJUSTING, AND BALANCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
PRINCIPAL INVESTIGATOR REGISTRATION FOR SELECT AGENTS
Page 1 of 5 PRINCIPAL INVESTIGATOR REGISTRATION FOR SELECT AGENTS In order to gain approval by the CDC for use of select biological agents the CDC requires, as part of their application procedure (Sections
MAC 10. Original & IQ FAMILY OF FAN FILTER UNITS
MAC 10 Original & IQ FAMILY OF FAN FILTER UNITS used in: microelectronics medical device semiconductor disk drive laboratory pharmaceutical markets hospitals clean rooms Table of Contents MAC 10 Original
ACC1-10, ACC1-25, ACC1-50, ACC1-125
FAN FILTER DIFFUSER PRODUCT OVERVIEW TABLE OF CONTENTS Page No. 92FFD Series Fan Filter Diffusers Aluminum or Stainless Steel 3 Dimensional Data 4 Performance Data 5 ECM Technology 7 RMBC (Room-Side Removable
ELECTRONICS RESTORATION
ELECTRONICS RESTORATION THE POWER OF KNOWLEDGE 00:00:00 00:01:00 00:02:00 00:03:00 00:04:00 Recovery Reinstatement electronics restoration 00:02:00 00:03:00 00:04:00 SAVING YOU TIME AND MONEY BELFOR's