COMPENSATION OF REACTIVE INPUT POWER POWER CONSUMPTION

Similar documents
PowerGem Pro Uninterruptible Power Supply

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

LAP ENERGIA PARA DATACENTERS

Technical Data. back-up time in minutes 100% load % load

RIELLO ELETTRONICA. Master HP

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Phase Modular Finally the benefits of Modular ups are for all

MAJORSINE Power Inverter

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Model #: SMART2200CRMXL

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

Uninterruptible Power Supply

The UPS for the highest security in industry and data centres

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

4.0 UPS dedicated to ICT for unmatched energy savings

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

BB800 Off-Grid Solar System

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

USER MANUAL Online UPS 1K/2K/3K Rack

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

USER MANUAL Online UPS 1K/2K/3K

Galaxy VM. Three-phase power protection. schneider-electric.com

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

UNINTERRUPTIBLE POWER SUPPLY (UPS)

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

User Manual 1K/2K/3K Online UPS

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Assembled in Florida, USA.

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Online UPS. PowerWalker VFI 1000R/1U

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

USER MANUAL Online UPS 6K/10K RACK

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Chassis, Power Supply, and Element Management

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

Technical Specification Kohler PW 5000/TP

User s Manual Before using the inverter, you need to read and save the safety instructions.

Liebert NXC from 10 to 200 kva

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

SNMP Web Management. User s Manual For SNMP Web Card/Box

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Back-UPS Pro 1300/1500 Installation and Operation

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Quick Connect. quick - simple - efficient.

GB USER S MANUAL GB 41

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Smart-UPS On-Line 230 V

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

Eaton 93PM UPS Where aesthetics meet intelligence.

Frequency Converter Fv

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

NC-12 Modbus Application

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

Temperature & Humidity SMS Alert Controller

FIREDEX Conventional Fire Panels

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

UPS system for emergency lighting and smoke extraction

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

How To Use A Power Supply Unit (Upu)

SG Series UPS kva three phase 400 Vac

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

R5000 Uninterruptible Power System (UPS) Overview

Power Meter Series 700

VISION UPS UPS PRODUCT CATALOGUE

Transcription:

ENSURE CONTINUITY OF POWER SUPPLY DATA SHEET HIGH EFFICIENCY WARRANTY COMPENSATION OF REACTIVE INPUT POWER HYBRID WORK POWER CONSUMPTION UPS from series are on-line (VFI) class devices, intended to work with devices powered with three-phase grid. Appliances are dedicated to work with especially sensitive receivers. This is a series of technologically advanced uninterruptible power supplies intended mainly for servers, networks and data processing systems. COMMUNICATION USB, RS 232 and RS 485 communication interface MODBUS (optional) Controlling inputs Programmable dry contacts SNMP/HTTP Network Managing Card (optional) External management panels with Android systems (optional) SERVICE Service on-site 5-year warranty on UPS* *requared annual payable maintenance check PROTECTION In order to ensure the reliable and safe operation, UPS is equipped with a number of protections. They defend both the same device (overload, short-circuit, thermal protection), as well as the connected loads (surge protection) from threats associated with their operation.

PARAMETRY BENEFITS FORTECHNICZNE USERS OF UPS On-line operation using real double conversion, with sinusoidal output voltage (with the highest quality VFI-SS111 parameters). UPS input reactive power compensation with tangible financial benefits resulting from reduced bills for reactive power consumption. High short-circuit current which helps to achieve high selectivity of the protection available for the power distribution lines. Hybrid operation mode extending backup time (in BATTERY mode) by ensuring power is supplied to the inverter concurrently from batteries and from the power grid with poor/insufficient parameters - this is available for a specific range of network voltage degradation (very wide input voltage window). Achieving high efficiency over a wide range of loads thanks to the use of high quality components. Dynamic cooling management algorithm designed to allow adaptive adjustment of the cooling system capacity to the current state of the UPS unit (to minimize power losses and to reduce the costs associated with the demand for cooling). The Intelligent Battery Management technology utilizes the advanced battery management strategy in order to extend battery life and to optimize the charging time and charging energy efficiency. Availability of the ECO mode further improves the efficiency of the power supply system (through the ability to differentiate between periods with varying degrees of supply reliability). Scalability (extending) of the backup operation time thanks to the possibility of connecting larger number of external battery packs to the UPS unit (optional). The scalability of the power supplied by the UPS. The Start-on-battery function enables the UPS unit to be started even if power supply from the mains is not available (the so-called "Cold start feature). Capable of operating in conjunction with external control panels (using the Android system), and using a RS232, RS485 or USB communication interface, SNMP/HTTP network management card, control inputs and programmable volt-free outputs. It uses an integrated LCD operator's control panel (with adjustable angle). All these are designed to allow a customised UPS remote control strategy. Remote Emergency Power Off (Remote EPO) functionality which interrupts power supply from the UPS output to loads in extreme situations or in emergency (e.g. fire). Obtaining information about temperature and humidity on the basis of measurements making it possible to analyse the environmental parameters. Events Log records and stores the data related to the events that have occurred during the operation of the UPS unit (recording the modes of operation, alerts and messages related to the device). Soft start ensures correct start of the UPS system (provides protection against formation of transitional states). Fast and easy replacement of batteries by qualified service staff, to minimize the service time which translates into genuine financial benefits for the user.

TECHNICAL DATA PARAMETERS \ TYPE Part number Output Power (Apparent / Active)1) Model 10k Model 15k Model 20k Model 30k Model 40k Model 50k Model 60k -3310K0/00-3315K0/00-3320K0/00-3330K0/00-3340K0/00-3350K0/00-3360K0/00 10 kva 10 kw 15 kva 12 kw 20 kva 16 kw 30 kva 24 kw 40 kva 32 kw 50 kva 40 kw 60 kva 45 kw < 8200 < 10300 < 11600 50 A 62 A 70 A GENERAL DATA AND ENVIRONMENTAL Topology VFI (on-line, VFI-SS-111) Note: The manufacturer reserves the right to modify the above parameters without prior notification. Number of phases (in/out) 3/3 Housing Type Tower Max efficiency (double conversion mode) < 94% Max efficiency (ECO mode) > 98% Operating temperature 2) 0 +40 C Storage temperature 0 +40 C Relative humidity during operation < 95% (non-condensing) Relative humidity during storage < 95% (non-condensing) Operating elevation 3) < 1000 m Protection level IP20 Environment of installation Separate rooms with low contamination level Cooling Forced, internal fans Temperature of the cooling air Quantity of heat released for nominal work conditions < 25 C < 2600 < 3100 < 4100 < 6200 INPUT Nominal input voltage 3 x 400 V AC Input voltage range and tolerance Rated current 173 485 V AC ± 2% 16 A 19 A 25 A Input voltage rated frequency 37 A 50 Hz Input voltage frequency range and tolerance 45 55 Hz ± 1 Hz Input Power Factor > 0,99 Input current distortion (THDi) <3% Reactive power compensation 0 var Reactive power factor tg ϕ < 0,4 Notes: 1) For standard operation, the load applied to the output must not exceed 80% of the value in the table. The power margin is necessary to ensure continuous work of the connected devices in the case of instantaneous surges of the load. 2) For UPS with internal batteries 5 35 C. Constant exposure of the battery module to temperatures of +25 C reduces the battery life. 3) The permitted maximum load of the power supply unit decreases with the height above the sea level above the limit specified above. EPO EPO (Emergency Power Off) is a mechanism that allows to interrupt energy supply to loads from the output of UPS in extreme situations (e.g. fire). The mechanism may be triggered by opening a dedicated pins attached to the external connectors located EPO on the rear side of the housing or induced remotely from the user interface.

TECHNICAL DATA PARAMETERS \ TYPE Model 10k Model 15k Model 20k Model 30k Model 40k Model 50k Model 60k 73 A 87 A 3:1 3:1 OUTPUT Nominal output voltage 3 x 400 V AC Output voltage range and tolerance - normal mode 3 x (380 415) V AC ± 2 %, configurable Output voltage range and tolerance - battery mode Rated current 3 x (380 415) V AC ± 2 %, configurable 15 A 22 A 29 A Shape of output voltage (battery mode / normal mode) 58 A sine-wave / sine-wave Output voltage rated frequency Note: The manufacturer reserves the right to modify the above parameters without prior notification. 44 A 50 Hz Output frequency range and tolerance - mains operation mode Synchronously Output frequency range and tolerance - battery mode 50 Hz ± 0,1 Hz Output voltage regulation < 1% < 1,2% for Pmax (line) < 5% (non-line by PN-EN 62040-3) Output voltage distortion THDu Crest Factor CF 7:1 5:1 4:1 Transfer time to battery mode 5:1 4:1 0 ms Transfer time to normal mode 0 ms 130% - 10 min 160% - 1 min 300% - 100 ms Overload capability 4) BATTERIES AND TYPICAL RUNTIME Internal Batteries 12 V / 7 Ah VRLA or 12 V / 9 Ah VRLA Number of internal batteries 64 (2 x 32) Maximum overall internal batteries capacity 9 Ah External battery modules (EBM) Yes Maximum overall external batteries capacity 200 Ah 400 Ah Backup time - internal batteries ( 100 % / 80 % / 50 % Pmax) Depends on the type and number of batteries Backup time - internal batteries + EBM (100%/80%/50%Pmax) Depends on the type and number of batteries Nominal voltage DC circuit 384 V DC Internal batteries maximum charging time - after discharging at 80 % Pmax Depends on the type and number of batteries Maximum charging current 10 A Notes: 4) With long-term operation of the load of the recommended values. USER INTERFACE Positionable LCD panel with keyboard allow user possibility to observe and modify parameters of UPS. 500 Ah 20 A 25 A

TECHNICAL DATA PARAMETERS \ TYPE Model 10k Model 15k Model 20k Model 30k Model 40k Model 50k Model 60k MECHANICAL SPECIFICATIONS Dimensions (H x W x D) Net Weight 5) Gross Weight 5) Transport Dimensions (H x W x D) 955 x 435 x 860 mm 1210 x 490 x 860 mm 1210 x 490 x 860 mm 265 kg 320 kg 340 kg 280 kg 335 kg 355 kg 1045 x 800 x 1200 mm 1300 x 800 x 1200 mm 1300 x 800 x 1200 mm Position in which devices transported Vertical Note: The manufacturer reserves the right to modify the above parameters without prior notification. PROTECT Input over current protection Short-circuit / Overload Three-pole breaker B32 A / 400 V AC Short-circuit / Overload Three-pole breaker B63 A / 400 V AC Short-circuit / Overload Three-pole breaker B100 A / 400 V AC Surge Protector Bypass line working - short-circuit and overload protection Output over current protection DC over current (internal batteries) DC over current (external battery input) Inverter working electronic short-circuit and overload protection 2 x 30 A / 440 V DC cylindrical 10 x 38 2 x 63 A / 440 V DC 2 x 100 A / 440 V DC 2 x 30 A / 440 V DC cylindrical 10 x 38 (optional equipment) 2 x 63 A / 440 V DC (optional equipment) 2 x 100 A / 440 V DC (optional equipment) ACCESSORY AND EXTRA FUNCTIONS Power supply connection 3P5W 3P5W screw terminals; max. 16 mm2 (cable) screw terminals; max. 35 mm2 (cable) 3P5W Output connection (number and type of sockets ) screw terminals; max. 35 mm2 (cable) EPO Signalling Communications interfaces Yes (NC) Acoustic and optical; LCD display, synoptic diagram RS232, RS485, USB, programmable dry contacts (4), control inputs (5) 6), MODBUS optional, network management card SNMP / HTTP (optional), external managements panels with Android systems (optional) Software PowerSoft Professional Parameters programmable dry contacts 1 A / 250 V AC CERTIFICATION Declarations Standards CE PN-EN 62040-1:2009, PN-EN 62040-2:2008 Notes: 5) Weight for the typical battery set-up 1x 2x 32x VRLA 12V / 7Ah. Weight depends on the type and number of batteries. 6) For the unit with the MODBUS option input no. 5 is not available. COMMUNICATION UPSs are equipped with enhanced management capabilities. There is dedicated software PowerSoft Professionall supplied with the device. Communication with the computer is done via RS232 and USB port placed on the back panel of enclosure. Additionally UPS work can be managed and monitored through an LAN network. Thanks to an additional, mounted optional, SNMP/HTTP managing card you can remotely monitor the operation of the device. This card has implemented SNMP agent service and HTTP server. Four sets of universal relay dry contacts make possible to inform about certain states of UPS. User can manually configure the appropriate contacts assigning them selected state or event e.g. main mode, overload.

REAR PANEL 17 4 1 8 2 3 7 5 17 4 1 2 8 6 3 7 5 9 6 9 11 11 10 10 12 12 13 13 14 14 15 16 model 30-60 kva 15 16 model 10-20 kva 1) EPO connector, 2) Communication bus connectors for parallel operation, 3) Programmable outputs (nonvoltage contacts), 4) Control inputs, 5) USB communication interface, 6) RS232 communication interface, 7) RS485 communication interface, 8) Adapter/expansion card slot plug, 9) Fans, 10) BYPASS (service) system switch (optional), 11) Protection, internal batteries (F1, F2), 12) Protection, DC input lines (F5) optional, 13) Protection, basic input lines (F4) and optionally BYPASS input lines (F3), 14) Cover, terminal connectors, 15) Mounting brackets, 16) Caster wheels to move the UPS, 17) DC power connection (12 V DC / 1A non-stabilised) - optional EVER Sp. z o.o. ul. Wołczyńska 19, 60-003 Poznań, Poland tel. +48 61 6500 400, fax +48 61 6510 927, e-mail: ups@ever.eu