Installation Guide: PowerAire Quad

Similar documents
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

FG MOISTURE MONITOR Installation & Operation Manual

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Raised Floor Data Centers Prepared for the Future

Cabinets 101: Configuring A Network Or Server Cabinet

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

8 Channel Status Input Panel model SIP-8

Control Box Wiring For PRSstandard Tool

APC APPLICATION NOTE #112

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

In-Floor Cooling Solutions. In-Floor Cooling Solutions. Airfl ow Management Solutions for Raised Floor Data Centers

Instrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.

INSTALLATION INSTRUCTIONS

ELECTRONICS G H I J K L M

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

Setting Up the Cisco IP Phone

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Installation Instructions

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

AU-110 racking guide NBXPN: 023

DCF Optimized Rack System

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

Setting Up the Cisco Unified IP Phone

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

This Document Contains:

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

Serial ATA to Serial ATA

Panel Track Installation Guide

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Rack Installation Instructions

Liebert DCR Part of the SmartRow Offering. Installation Manual 3-6, Single/Redundant and 5-10 Racks Higher Capacity Cooling Units, 60Hz

Kiosk Group, Inc. ASSEMBLY INSTRUCTIONS FOR THE STANDALONE. EXQUISITE ipad KIOSK. For ipad Version Tablets.

INSTALLATION & SERVICE MANUAL. Display Panel

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Rack installation instructions

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

HP SATA/SAS hard drive and Solid State Drive installation

MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system way pager system

MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system way pager system

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

DE Frame with C Series Sidelight

42U/45U 28" Wide Rack Installation & Service Guide

Installation of Rear View Camera in a 1995 Roadtrek 190 Popular

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA / (fax)

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

2. Remove rear cover of head lamp if bulbs are covered/sealed within the housings, and remove halogen bulb carefully.

Fan, Cypress / GreenField Installation Instructions (sku )

To Purchase This Item, Visit BMI Gaming

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

SERVER ROOM CABINET INSTALLATION CONCEPTS

-Helping to make your life betterwww.person-to-person.net

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

MAINTENANCE & TROUBLESHOOTING

How To Fit A Dll 2420 And 4220 Rack Enclosure

Setting Up the Cisco Unified IP Phones

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

MAINTENANCE & TROUBLESHOOTING

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

4.3-inch Back-Up Camera

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

How to Set Up Your NSM4000 Appliance

Cooktop Low-Profile Ventilation Hoods

site monitoring Kit Site Monitoring Kit User Manual we prove it.

Customized Server Cabinets

GENUINE PARTS INSTALLATION INSTRUCTIONS

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

Automatic Phone-Out Home Monitoring Systems

PS6500 Storage Arrays Rack Mount Instructions

Quick Start Guide. RV0xx Series Routers

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Electrical Wiring Technical Bulletin

Part Name/Description Part Number Quantity. Power Cable

March 14, Installation of Bay, Bow and Garden Windows

Organizing and Managing Equipment Rooms

5800 Temperature Sensor Cable Assembly

Steel Door Frame Installation in Steel Stud Construction

Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs

Removing memory and option cards

Data center upgrade proposal. (phase one)

Utility Distribution Systems

Installation instructions, accessories - Handsfree for cellular phone, system B, entry level

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

Refer installation of power supplies to qualified service personnel.

StorTrends 3400 Hardware Guide for Onsite Support

Replacing the Gateway M675 Keyboard

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

Rack Installation Instructions

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

Transcription:

Installation Guide: Quad INSTALLATION GUIDE FOR POWERAIRE QUAD QUAD-FAN ASSIST Tel (410)799-4200 1 of 15

Installation Guide: Quad INTRODUCTION Tate s Variable Speed Quad Fan Assist device provides the user with unparalleled local control and reliability of airflow to precisely meet individual rack cooling demands in areas of low or no static pressure without user intervention. Automatic control based on user a defined set point guarantees that each piece of IT hardware installed in the users rack is supplied with sufficient air volume at all times. METHOD OF OPERATION Tate s Quad Fan product is designed to work in conjunction with the DirectAire Airflow Panels, to meet high airflow requirements and accurate air flow deliver to the rack face. The Quad Fan is designed to alleviate airflow issues in areas where little to no static pressure exists due to Underfloor restrictions, or insufficient floor heights. The TM Quad Fan is designed to function on most finished floor heights of 6 or greater. Since IT loads are rarely stable on a rack to rack basis, the Quad Fan is designed to throttle the amount of air delivered to an individual rack based on its current inlet air temperatures. This guarantees sufficient air delivery to the rack, as hot air recirculation would occur in insufficient airflow delivery situations. This balancing act is managed by a high speed PID controller which monitors each temperature sensor in a multi loop temperature evaluation mode. Each of the three sensors installed at the rack face are polled for current temperature value, and then compared to each other. The probe having the highest value is then used as the control point. This control point is then used to determine the correct speed for the variable speed fan. The command signal is sent to the fan controller, which then changes the fan speed producing more or less air to pass through the DirectAire or other airflow grate. PLEASE HELP US IMPROVE THIS MANUAL We would be very interested to hear any comments you might have on this installation manual. We are particularly interested in learning of omissions or subjects that are unclear. Please call, fax, or e-mail and direct your comments to Technical Service. Thank you very much for your assistance. Phone: (410) 799-4200 Fax: (410) 799-4207 E-Mail: TateInfo@Tateaccessfloors.com Tel (410)799-4200 2 of 15

Installation Guide: Quad INSTALLATION INSTRUCTIONS 1. Remove the unit from the factory packaging. Take care to check that each required separate component is in the shipping packaging as listed below, and figure 1 for details. A. 1 x Fan Assist Device B. 1 x Three Point Color Coded Temperature Sensor Tree(Quad- M only) C. 1 x single Point Temperature sensor Tree (Quad-S only) D. 10 x Temperature Sensor Tree Zip Ties (Quad-S and M only) E. 4 x Tool Less Roll Formed Stringer Hangers F. 1 x power cord Not Pictured: The Quad is designed for optimum use with Tate s DirectAire airflow panel ordered separately; other airflow panels may reduce the performance of the Quad. Figure 1 - Illustrated Parts List 2. Remove the existing airflow panel, and installed the four Tool Less Roll Formed Stringer Hangers into the stringer system. The hangers should be oriented with the larger angled bottom hook facing into the center of the removed panel. Simply orient the hanger at a 45 degree angle with the floor, sliding hanger s smaller angled hook surface into the gap in the roll formed stringer s bottom surface, and then allow the hanger to roll back perpendicular to the floor surface. Repeat this for all four sides of the panel. See figures 2-4 below. Tel (410)799-4200 3 of 15

Installation Guide: Quad Figure 2 Position hanger parallel to the floor with short angled edge aligned to opening in roll form stringer Figure 3 - Insert hanger into roll form opening and catch the top angle inside the stringer Figure 4 - Release hanger and allow it to return perpendicular to the floor Tel (410)799-4200 4 of 15

Installation Guide: Quad 3. A more flexible alternative method of attaching the unit to the raised floor understructure can also be realized by the use of the corner cable hangers. These cable hangers shown in figure 5 below, can allow unit to hang from the pedestal head in cases were non roll formed stringers are in use. It may be necessary to install a screw in the pedestal head on which to hook the unit for hanging. Figure 5 - Alternative Corner Lock Hangers Figure 6 Power Outlet from Site Source 4. Each unit must be powered from the appropriate outlet. For 100-120V and 200-240V installations, a C14 power inlet is provided on the unit. The supply voltage of the unit will dictate the power cord supplied with the unit, which will be 6 feet in length, a list of the required power outlet is shown below in table 1. If the supplied cord does not meet the site requirements, a use supplied cord set may be used if it meets the voltage and amperage requirements of the power module. Figure 6 shows an example of a power feed to the unit. Table 1 - Power Feed Requirements for Unit Power Feed Requirements Voltage Outlet Required 100-120V NEMA 5-15R 200-240V NEMA L6-15R 5. Pick up the unit using the inside lip around the inside perimeter of the unit. Be sure to orient the units extended shroud below the rack. Lower the TM unit at the edge that extends beyond the perimeter of the unit first so that this edge will be oriented beneath the rack see figure 7 through 9 below. Lock the lip of the unit into the hanger, the lower the opposite side into the waiting Tool Less hanger. Once this side is also resting in the hanger support, manipulated the unit so that each hanger on the alternate sides are also secure the unit into place. Tel (410)799-4200 5 of 15

Installation Guide: Quad Figure 7 - Quad Unit Installed on hangers in correct orientation Figures 8,9 - Installation of Quad Unit onto Tool Less Hangers For Quad-Fan C units, Skip steps 6 and 7. 6. Plug in the temperature sensor tree into the labeled connection port on the left side of the unit when facing the rack. Route the temperature probes into the rack. This can typically be done by routing the probes through the cable entry hole serving the rack, or by drilling a new 0.5 hole at the front of the rack, through the panel directly below the rack. If a new hole is required, ensure that the hole is sealed after the temperature probes are completely routed, and that the holes edges are appropriately grommeted to decrease the risk of cable damage. Tel (410)799-4200 6 of 15

Installation Guide: Quad Figure 10 - Connection of temperature sensor tree 7. The placement of the sensors is at the user s discretion. The suggest location however would be along the perforated face of the rack door. The best method to accomplish this is to route the main trunk of the temperature sensor tree along the hinge side of the door, and then route the probes to the door surface, securing each probe to the inside surface of the door, while the door is completely open to ensure sufficient slack. Zip tie the cable trunk along the rack frame or where appropriate. Other alternatives for mounting the temperature sensors may include their installation along the frame of the rack or directly at the server inlets through various methods. In cases where racks are wider than a typical 24 panel, an individual rack may receive partial cooling from two panels. In these cases, simply double the sensor probes in these racks to allow for parallel operation of the units in question. The goal is to position the sensors in such a way that they are exposed to the continuous flow of intake air during normal IT operation. See figure 11 through 13 for routing examples. Tel (410)799-4200 7 of 15

Installation Guide: Quad Figure 11 - Routing temperature sensor tree through cable entry point Figure 12,13 - Temperature Sensor installation Securing Sensor Tree to with Sufficient Slack for Door Operation Quad- S or M units should skip step 8 8. For installation of Quad Fan C units a control signal of 0-10VDC should be provided via an alternate means than the provided equipment. This should be wired directly to the provided Phoenix type connector to the indicated connections. Tel (410)799-4200 8 of 15

Installation Guide: Quad 9. The unit can now be powered on by plugging it into (figure 14,15) the appropriate power outlet outline in table 1. Once power is applied, and the power switch is turn on, (figure 16) the unit will begin the startup procedure. This process is completed when the user display shows the current peak temperature. Figure 14- Connecting power to the unit Figure 15 - Plugging the power cord into the unit Figure 16 Location of Power Switch Tel (410)799-4200 9 of 15

Installation Guide: Quad For Quad-Fan C and S units, Skip steps 10 to 13. 10. The user should now set the desired supply air temperature that should not be exceeded at the IT rack intake. The menu of the controller is accessed as follows. A. Pressing the large button labeled SEL will allow the user to scroll through the current temperature values recorded as t1, t2, and t3. Each value will be displayed in sequence with pressing of the SEL button. Figure 17 below shows these steps. B. After the temperature values are displayed, pressing SEL again will show the current set point value indicated by SP. (Figure 17) C. Pressing the SEL button again will light the PRG buttons, and allow the user to adjust the set point as desired. Pressing either button once will adjust the set point 0.1F, holding the button for approximately 1 seconds will quickly adjust the set point in 1.0F increments. D. Pressing the SEL button again after the desired SP is entered will store the value and then display the current command fan speed the controller has sent to the fan. The fan will adjust to this value in time as the fan follows the command position. E. Pressing the SEL button again will return the user to main screen which displays the current peak temperature value recorded from the temperature sensor tree. Figure 18 shows this procedure. Figure 17 - Scrolling Through Temperature Values Tel (410)799-4200 10 of 15

Installation Guide: Quad 11. Once the value has been set, and all programming completed. Reinstall the DirectAire or other panel above the unit and proceed to the next unit. It is best to work right to left due to the connector layout on the unit. Each subsequent unit can fully access connector points on its neighboring unit, allowing for easier access to power connections. 12. The will now run automatically, increasing and decreasing fan speed as the temperature values change based on changing IT equipment conditions. The unit is meant to function as a hot spot reduction device, pulling air into areas with little or no static pressure due to underfloor restrictions, and insufficient floor heights. Best practices dictate that underfloor plenum spaces should have all unnecessary restrictions removed from beneath the floor, but often site conditions make this difficult or not cost effective. Figure 18 - Programming Set point for Control For Quad-Fan M and C units, Skip step 13. Tel (410)799-4200 11 of 15

Installation Guide: Quad 13. The user should now set the desired supply air temperature that should not be exceeded at the IT rack intake. The menu of the controller is accessed as follows. A. Pressing the SET button and hold it for approximately 2 seconds will display the value ST1, and then show the set point in flashing characters. Simply use the up and down buttons to adjust the set point. Press set once more and the new set point value will be stored. Figure 19 - Scrolling Through Temperature Value Figure 20 - Installation of DirectAire Panel Figure 21 - Typical Operation Tel (410)799-4200 12 of 15

Installation Guide: Quad 14. The units are completely maintenance free. The temperature display will continue to show the current peak temperature during normal operation. Power failure, or control failure will result in a 0% fan speed although air may still flow from the panel due to the effect of underfloor air pressure alone. After a power interruption event, the unit will reenter the last operation condition when power is restored. 15. The unit can affect the air flow that is delivered to other nearby panels if insufficient air delivery is widespread in the data center environment. The installer should verify after installation that sufficient air volume is reaching IT hardware in the vicinity of the installation location. Failure to do this may result in a reduction of airflow in neighboring panels, and should be avoided. 16. WARNING: The fan unit can start and stop at any time during normal operation, be sure to switch power off at the unit if accessing the unit. See figure 22 below Figure 22 - WARNING - Ensure power is switched off before accessing unit Tel (410)799-4200 13 of 15

Installation Guide: Quad 16. Figure 23 and 24 below show an overview of the wiring diagram and installation of each of the Quad units. 3 Probe Temperature Sensor Quad - M Quad - M Quad - S Quad - S Quad - S Quad - S 120/240VAC Nema Style Connector Single Probe Temperature Sensor Quad - M Quad - M Note: Quad S for use within the interior portion of an aisle. Figure 23 Quad M and S installation wiring diagram Tel (410)799-4200 14 of 15

Installation Guide: Quad Phoenix Type Terminal Connector Input Signal 0-10VDC (By Other) 120/240VAC Nema Style Connector Figure 24 Quad C installation wiring diagram Tel (410)799-4200 15 of 15