SERIES 1400 POWER SUPPLY SPECIFICATIONS Input. Output. Enclosure Dimensions/Type. Enclosure Weight A C S I , 1426, 1490

Similar documents
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

SECTION DETECTION AND ALARM

AC-115 Compact Networked Single Door Controller. Installation and User Manual

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

White Papers: Delayed Egress Hardware

SECTION LOW VOLTAGE LIGHTING CONTROLS

Understanding Emergency Power Off (EPO)

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

HM-W536 Install Guide

INSTALLATION INSTRUCTIONS

Electromagnetic Locks and Electrified Door Hardware. Paul Latreille, CET Branch Manager

Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4

FIREDEX Conventional Fire Panels

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

EQUIPMENT SPECIFICATIONS

INTRUSION DETECTION SYSTEM Section

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Understanding Access Control

PLAN REVIEW GUIDE FOR FIRE ALARM

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Harris County Fire Code Electronic Lock Procedures

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

ARCHITECT AND ENGINEER SPECIFICATION SECTION DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Fire Pump Controllers Remote Alarm Panels

Solid State Timers Type F

Middleborough Police Electronic Security Narrative

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

TS93 EMR T/PT/TDE. Surface applied door closer

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

Self Monitoring Power Supply (BPSM)

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

Speed Control Relays SX2

B. Division 16 Basic Materials and Methods sections apply to work of this section.

Doc 10. UTM Standards: Card Access Security System

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2

8900 EMR (WITH DETECTOR)

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

7200 series Electromechanical Closer/Holder

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION

EMF/EMR. Holder/Release Devices with Integral Door Closers

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

CONSULTANT PROCEDURES & DESIGN GUIDELINES ACCESS CONTROL SYSTEM

HARDWARE REQUIREMENTS FOR ACCESS AND EGRESS

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Architectural. Access Control System - CAAMS

Fire Alarm System Plans Review Checklist Property location Date of Review

4000 Series audio door entry system (using power supply) Installation Instructions IN9307.1

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

TABLE OF CONTENTS FEATURES

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

University of Houston Master Construction Specifications Insert Project Name

Table of Contents - 3 -

INSTALLATION MANUAL PC2525. Version 1.1

Reference & Installation Manual

728 SERIES REFERENCE & INSTALLATION MANUAL 728+ VERSION series

SECTION FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

INSTALLATION MANUAL XM3 Reader

SECURITY / ACCESS / FIRE / SURVEILLANCE

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

CalMod Design-Build Electrification Services

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Control/Communicator Installation Manual

SECTION FIRE ALARM AND DETECTION SYSTEMS

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

D287/D288/D292/D293A/D293E

Release Control Fire Alarm Systems

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

AUTODIALLER / QUICKDIALLER - SA132

*.ppt 11/2/ :48 PM 1

PLAN400 V6.6X. Networked Access Control Panel. Installation Guide

EKOS Cart. Instructions for Use

Shunt lock function 3066

TrueAlarm Fire Alarm Systems

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

HERNANDO COUNTY FIRE ALARM GUIDELINES

Electromagnetic locks

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

FIRE DETECTION AND ALARM

Adaptability to Enhanced Security

TABLE OF CONTENTS. Introduction 1. Components of a System 2. Door Control Hardware 3. Request to Exit Devices 5. Credential Technology 6

CB200W Water Leak Detection Panel Application Guide

Transcription:

1400 SPECIFICATIONS Input 1406, 1426, 1490-120VAC, 0.75A, 60Hz 1406BB, 1426BB - 120VAC, 1.08A, 60Hz 1410, 1420, 1440, 1400-6100 - 120VAC, 0.9A, 50/60Hz - 240VAC, 0.6A, 50/60Hz Output 1406, 1426-1550 Device Outputs: 40VDC, 1.5A (combined) Filtered/Unregulated - Auxiliary 24V Output: 24VDC, 0.25A Filtered/Unregulated - Auxiliary 12V Output:12VDC, 0.25A Filtered/Unregulated 1406BB, 1426BB - 1550 Device Outputs: 40VDC, 1.8A (combined) Filtered/Unregulated - Auxiliary 24V Output: 24VDC, 0.2A Filtered/Unregulated 1490-24VDC, 2.0A Filtered/Unregulated 1420, 1440, 1400-6100 - 24VDC, 2.0A Filtered/Regulated 1410-24VDC, 2.2A Filtered/Regulated Enclosure Dimensions/Type 1406, 1410, 1420, 1426, 1440, 1400-6100 - 10 x10 x4, NEMA Type 1 Screw Cover Junction Box 1406BB, 1426BB - 12 x16 x4, NEMA Type 1 Screw Cover Junction Box 1490-12 x14 x4, Surface Mount Cabinet w/hinged Door and Keyed Lock Enclosure Weight 1410-9 lbs (w/all four plug-in boards installed onto mother board) 1406, 1426-12 lbs 1406BB, 1426BB - 26 lbs (w/batteries) 1420, 1440, 1400-6100 - 8 lbs 1490-15 lbs (w/all zone cards installed) A C S I 1-8 0 0-7 5 3-5 5 5 8 2720 Clark Avenue St. Louis, Missouri 63103 1-800-753-5558 314-652-5588 FAX: 314-652-2090 WWW.ACSI-INC.COM

L O C K I N T O T H E A C S I A D VA N TA G E P O W E R S U P P L Y C A T A L O G 2720 Clark Avenue St. Louis, Missouri 63103 1-800-753-5558 314-652-5588 FAX: 314-652-2090 WWW.ACSI-INC.COM

THE SINGLE SOURCE FOR LOCKING DEVICE SUPPLIES ACSI Series 1400 Power Supplies are designed and manufactured by ACSI engineers to operate a variety of electric locking devices that will meet the most sophisticated specifications. ACSI system engineers are available to assist you in the selection of the power supply that best meets your application. All ACSI designed systems include riser diagrams and point-to-point wiring diagrams that allow ease of interface with life safety and security systems. Architectural Control Systems, Inc. 2720 Clark Avenue St. Louis, MO 63103 314-652-5588 FAX: 314-652-2090 1-800-753-5558 www.acsi-inc.com 1410, 1420, 1440, 1400-6100 SUPPLIES U L Features UL Listed and tested to UL 294 standard Filtered/Regulated 24 VDC Class 2 rated outputs 2 amp load capacity Overload protection Over voltage protection Short circuit protection Surge suppression on fail safe and fail secure outputs Automatically accepts 120VAC or 240VAC input

1490 DELAYED EGRESS The ACSI 1490 Power Supplies are designed to interface with ACSI electromagnetic locks in a delayed egress locking application. Features UL Listed Compliance with NFPA code requirements Rated 24VDC, 2 amps (max) Input for delayed egress activation Manual reset of delayed egress alarm Optional auto reset available Input for fire alarm interface Output for audible alarm Field adjustable delay for nuisance alarm, door release, request to exit, and auto reset delay times One power supply can provide up to 4 delayed egress alarm zones Description of System Operation The delayed egress alarm becomes activated when the push bar of the Series 1500 modified exit device is depressed. A concealed AE (request to exit) switch initiates an irreversible cycle that begins with the Series 1300 audible alarm sounding for a predetermined time (field adjustable) while the Series 3700 electromagnetic lock remains energized locking the door. At the end of the timing cycle, the electromagnetic lock de-energizes and unlocks the door while the audible alarm continues sounding. The door will remain unlocked and in an alarm state until manually reset by the Series 1300 key switch. Resetting the system will lock the door by energizing the electromagnetic lock, and will turn off the audible alarm. Note: When using the system with a door position switch, the door must be fully closed prior to resetting the system. Resetting with the door open will energize the electromagnetic lock, but will not turn off the audible alarm. The audible alarm will also begin sounding if a forced entry occurs while the system is armed. In the event of a fire alarm, the electromagnetic lock will immediately de-energize to unlock the door. Upon resetting the fire alarm, the system will return to normal standby operation. Models Available 1490-21 1 zone card 1490-22 2 zone cards 1490-23 3 zone cards 1490-24 4 zone cards ACSI 1490 Application 3700 ELECTRO- MAGNETIC LOCK 1550 AE EXIT DEVICE WIRES IN CONDUIT (IF FRAMES ARE FILLED) 1100 HINGE 1490 1300 AUDIBLE ALARM/RESET SWITCH 302-03-03 MORTAR GUARD TO FIRE ALARM NORMALLY CLOSED CONTACTS

1420 Built-in time delay between activation of electrified locking device and automatic door operator Input for fire alarm or optional emergency release switch when urgent unlocking of the door is required Auxiliary 24VDC constant voltage output Separate 24VDC outputs for fail safe and fail secure electrified locking devices ACSI Automated Door Opening System AUTOMATIC OPERATOR 1420 ACSI 1420 Power Supply provides power and control for openings with an electrified locking device and automatic door operator. Each 1420 includes: Separate inputs for activation switch on entry and exit sides of the opening Relay contact output to automatic door operator (N.O. or N.C. contacts) 1700 STRIKE HANDICAP WALL ACTIVATION SWITCH 1440 Interface relay to isolate the locking device current from the control switch Auxiliary 24VDC constant voltage for powering stand alone devices, such as keypads, motion detectors, status indicators, etc. Field terminal block set at 45 for ease of installation ACSI Locking System 1440 ACSI 1440 Power Supply provides power for fail safe or fail secure locking devices. Each 1440 includes: 1300 CONTROL M1500 MORTISE LOCK 1590 CABLE 1100 HINGE WIRES IN CONDUIT 302-03-03 MORTAR GUARD

1400-6100 A C S I 1-8 0 0-7 5 3-5 5 5 8 Outputs to electrified locking devices that are field selectable for fail safe or fail secure function Up to 1 amp current draw allowable for each of two outputs to electrified locking device Inputs available for optional emergency release switch when urgent unlocking of the door is required Convenient field wiring of system components ACSI 1400-6100 Power Supply is used exclusively with the ACSI Series 6100 Communicating Door (Common Bath) System. The ACSI 1400-6100 Power Supply includes: Description of System Operation When the bathroom is not occupied, both doors are unlocked, and all indicators are extinguished. Upon entering the bathroom from one of the rooms, the occupant depresses the inside push-button switch to lock both doors (both doors must be closed in order for them to lock). When the doors lock, the red indicators inside the bathroom indicate that both doors are locked from the outside. The green indicators outside the bathroom denote that the bathroom is occupied. (Note: Both doors are always free egress and can always be unlocked mechanically from the outside with a key). When the occupant exits either door, both doors automatically return to the unlocked condition and all indicators are extinguished. ACSI Communicating Door System 1400-6100 1335-3 POSITION SWITCH VIEW FROM INSIDE BATHROOM C1500 CYLINDRICAL LOCK 1340-6100 OCCUPIED INDICATOR ROOM 1 1590 CABLE 1100 HINGE 1590 CABLE 1300-6100 PUSH TO LOCK SWITCH W/INDICATOR ROOM 2 1 2

1406/1426 SUPPLIES ACSI 1406 and 1426 Power Supplies are designed to operate exit devices equipped with ACSI Series 1550 Electric Latch Retraction. ACSI 1406 Application Features UL Listed and tested to UL 294 standard for access control system units Class 2 rated outputs Overload, over voltage and short circuit protection 1406 Series only: Select from independent control of single exit devices from separate inputs (one or two single doors) or sequential operation of two exit devices from a single input (pair of doors) Automatic door operator interface Fire alarm interface Field adjustable latch retraction time delay 24VDC, 12VDC* constant voltage outputs (250mA each) CARD READER CONTROLLER CARD READER 1550 LATCH RETRACTION EXIT DEVICE 1100 HINGE 1406-04-AO WIRES IN CONDUIT 302-03-03 MORTAR GUARD *Not available in battery backup models Day/Night Mode-ACSI 1426 Power Supply Provides a separate input for retracting one exit device or two exit devices sequentially without activating the automatic door operator. While the latches are held retracted, the auto-operator can be activated independently from a different input. ACSI 1426 Application with Day/Night Feature CARD READER CONTROLLER 1426-04-AO 1406BB/1426BB Power Supplies with battery backup All the same features as above, but includes built-in battery backup power: 4 hours of backup power at full load during AC power failure Standby battery power with a supervised AC failure output and low battery output Supplied with (2) 12V@7AH lead acid batteries CARD READER HANDICAP WALL ACTIVATION SWITCH 1550 LATCH RETRACTION EXIT DEVICE WIRES IN CONDUIT (IF FRAMES ARE FILLED) 1100 HINGE 1300 DAY/NIGHT CONTROL 302-03-03 MORTAR GUARD

1410 Separate plug-in p.c. boards used to control interlocking doors can be programmed for normally locked or normally unlocked operation. Inputs are available for fire alarm and optional emergency release interface for override of the interlocking system. Applications include darkrooms, laboratories, pharmaceuticals, detention centers, money counting rooms, airlocks, clean rooms, etc. ACSI system engineers are available for design and consultation services to coordinate all aspects of the system. ACSI 1410 Interlock Power Supply is designed to interconnect two or more doors using fail safe locking devices. Each supply can control up to four doors; and the system can be expanded for requirements in excess of four doors. Any one door can be programmed to be part of (common to) as many as three separate interlocking systems. ACSI electric locking systems and all documentation including riser diagrams and point-to-point wiring diagrams can give distributors a single source for their system requirements. Models Available 1410-2 2 Door Interlock 1410-3 3 Door Interlock 1410-4 4 Door Interlock ACSI Interlock System CARD READER CONTROLLER 3700 ELECTROMAGNETIC LOCK CARD READER 1410 TO FIRE ALARM NORMALLY CLOSED CONTACTS 1340 STATUS INDICATORS (4 TYPICAL) 1300 EMERGENCY RELEASE 1300 CONTROL (3 TYPICAL) CORRIDOR AIR LOCK CLEAN ROOM