FLOW REGIME MAPPING, VOID-QUALITY RELATIONS AND PRESSURE DROP IN TWO PHASE FLOW

Similar documents
The Analysis of Two-Phase Condensation Heat Transfer Models Based on the Comparison of the Boundary Condition

Optimization of Heat Sink Design and Fan Selection in Portable Electronics Environment

Solving Equations and Inequalities Graphically

Darcy Friction Factor Formulae in Turbulent Pipe Flow

16. Heat Pipes in Electronics Cooling (2)

Exponential Functions

Define conversion and space time. Write the mole balances in terms of conversion for a batch reactor, CSTR, PFR, and PBR.

1 Introduction. 2 Electric Circuits and Kirchoff s Laws. J.L. Kirtley Jr. 2.1 Conservation of Charge and KCL

THE MODELING AND CALCULATION OF SOUND RADIATION FROM FACILITIES WITH GAS FLOWED PIPES INTRODUCTION

CFD Analysis Of Multi-Phase Flow And Its Measurements

Hewlett-Packard 12C Tutorial

Power functions: f(x) = x n, n is a natural number The graphs of some power functions are given below. n- even n- odd

C. starting positive displacement pumps with the discharge valve closed.

APPLICATION OF TRANSIENT WELLBORE SIMULATOR TO EVALUATE DELIVERABILITY CURVE ON HYPOTHETICAL WELL-X

The Composition of Metals and Alloys

Solving Newton s Second Law Problems

AEROSOL STATISTICS LOGNORMAL DISTRIBUTIONS AND dn/dlogd p

Projectile Motion THEORY. r s = s r. t + 1 r. a t 2 (1)

Rosemount Orifice Plate in Wet Gas

CFD Simulation of Subcooled Flow Boiling using OpenFOAM

CASL-U

Experiment 3 Pipe Friction

FIXED INCOME ATTRIBUTION

THE SIMPLE PENDULUM. Objective: To investigate the relationship between the length of a simple pendulum and the period of its motion.

5.2. Vaporizers - Types and Usage

Prediction of Pressure Drop in Chilled Water Piping System Using Theoretical and CFD Analysis

Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter

6/2016 E&M forces-1/8 ELECTRIC AND MAGNETIC FORCES. PURPOSE: To study the deflection of a beam of electrons by electric and magnetic fields.

Two-phase flow modelling within expansion and contraction singularities

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

Statistical Mechanics, Kinetic Theory Ideal Gas. 8.01t Nov 22, 2004

Mathematical Modelling and Design of an Advanced Once-Through Heat Recovery Steam Generator

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

Laboratory Exercise: The Precision of Volume Measurements

Using Freezing-Point Depression to Find Molecular Weight

VALIDATION, MODELING, AND SCALE-UP OF CHEMICAL LOOPING COMBUSTION WITH OXYGEN UNCOUPLING

THE DIFFERENCE BETWEEN COEFFICIENT-OF-FRICTION AND DRAG FACTOR

Chapter 28 Fluid Dynamics

Modeling and Simulations of Cavitating and Bubbly Flows

Calibration and Uncertainties of Pipe Roughness Height

On the Influence of the Prediction Horizon in Dynamic Matrix Control

DIPE: DETERMINATION OF INPUT PARAMETERS UNCERTAINTIES METHODOLOGY APPLIED TO CATHARE V2.5_1 THERMAL-HYDRAULICS CODE

Lab 4: Magnetic Force on Electrons

Physical Properties of a Pure Substance, Water

Free Convection Film Flows and Heat Transfer

Qualification of Thermal hydraulic codes within NURESIM D. Bestion (CEA, France)

ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts

Technical Publication

FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES

Dynamic Process Modeling. Process Dynamics and Control

Table 1 Mechanical Properties of Pipe Table 2 Section Properties of Pipe and Reinforcing Dowel The Fitting with the Rib

Prelab Exercises: Hooke's Law and the Behavior of Springs

Chapter 12 IVP Practice Problems

Pipe flow with friction losses solutions using HP and TI calculators By Gilberto E. Urroz, October 2005

Hydraulics Laboratory Experiment Report

CMOS Differential Amplifier

cmn_lecture.2 CAD OF DOUBLE PIPE HEAT EXCHANGERS

2.1: The Derivative and the Tangent Line Problem

CHAPTER: 6 FLOW OF WATER THROUGH SOILS

Use of OpenFoam in a CFD analysis of a finger type slug catcher. Dynaflow Conference 2011 January , Rotterdam, the Netherlands

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

A HyFlex Module for the Personnel Scheduling Problem

AP Physics 1 and 2 Lab Investigations

Graphing Linear Equations in Two Variables

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

The numerical values that you find are called the solutions of the equation.

Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment

Physical Chemistry Laboratory I CHEM 445 Experiment 6 Vapor Pressure of a Pure Liquid (Revised, 01/09/06)

Density. mass m volume V

Work, Energy & Power. AP Physics B

Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software

REACTION RATES DOE-HDBK-1019/1-93 Reactor Theory (Neutron Characteristics) REACTION RATES

Heat and Mass Transfer Calculation of the Intercooler With Spraying Water for Air Compressor

Pressure -Temperature Relationship in Gases. Evaluation copy. Figure ml Erlenmeyer flask. Vernier computer interface

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

HOW TO CALCULATE PRESSURE ANYWHERE IN A PUMP SYSTEM? Jacques Chaurette p. eng. April 2003

Using light scattering method to find The surface tension of water

Heat Pipe Selection Revision 12/04/2001

Thermodynamics. Chapter 13 Phase Diagrams. NC State University

Quality assurance of solar thermal systems with the ISFH- Input/Output-Procedure

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

Partial f (x; y) x f (x; x2 y2 and then we evaluate the derivative as if y is a constant.

Status of EVOLVE boiling flow regime experiments

Flow Measurement Options for Pipeline and Open Channel Flow

FETE Complete Illustrative Solutions Fall 2010

Steady Heat Conduction

Advances in Thermal Dispersion Mass Flow Meter Accuracy

Thermochemistry. r2 d:\files\courses\ \99heat&thermorans.doc. Ron Robertson

!!! Technical Notes : The One-click Installation & The AXIS Internet Dynamic DNS Service. Table of contents

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

1-4 kg/m3. Long in-line calibration cycles of the gamma density systems may improve measurement accuracy, but this is often not practical subsea.

CFD Topics at the US Nuclear Regulatory Commission. Christopher Boyd, Ghani Zigh Office of Nuclear Regulatory Research June 2008

One of the fundamental design elements that every

Transcription:

FLOW REGIME MAPPING, VOID-QUALITY RELATIONS AND PRESSURE DROP IN TWO PHASE FLOW Dr. J. Michael Doster Nuclear Enineerin Department North Carolina State University

INTRODUCTION Two-phase lows (e.. steam and water) occur in many nuclear reactor components. For eample, the steam enerators and pressurizer in Pressurized Water Reactors and the reactor core reion o Boilin Water Reactors are classic eamples o where steam and water low toether as a two-phase luid. The compleity o the processes associated with two-phase low has required that analyst combine some orm o phenomenoloical modelin with empirical correlations. As it is virtually impossible to ind one epression that is valid over the entire rane o twophase conditions, correlations are usually developed that apply to speciic "low reimes" or low patterns. This requires that we be able to identiy these low reimes and the transition rom one low reime or heat transer reime to another. A number o low reimes have been ound to eist eperimentally by visually observin low patterns associated with the low o liquid-vapor mitures throuh transparent tubes. While the number and characteristics o speciic low reimes are somewhat subjective, our principal low reimes are almost universally accepted. These include Bubbly Flow (a &b), Slu Flow (c), Churn or Churn-Turbulent (d), and Annular (e). These patterns are illustrated in Fiure 1. (a) (b) (c) (d) (e) Fiure 1: Typical Flow Reimes (From Thermohydraulics o Two-Phase Systems or Industrial Desin and Nuclear Enineerin, by J. M. Delhaye, M. Giot and M. L. Riethmuller Measurements on air-water systems can oten provide insiht into the behavior o more eneral two-phase low systems. This typically requires that the air-water system have provisions or visualization o the low pattern, direct measurement o the air and liquid low rates, pressure drop and measurement o the vapor and liquid volume ractions. Visualization o the low patterns requires that at least some portion o the test section be transparent. While a number o techniques are available or measurin volume raction, one o the most direct is to measure the attenuation o a collimated beam o amma rays. A two-phase/air-water acility has been constructed in the R3 Bay in the Nuclear Enineerin Department. Instrumentation or pressure drop and low rate provide an analo sinal which can be interaced to the computerized data acquisition system on the SPWRF. This acility can be used to enerate low reime "maps" which are used to predict low patterns based on system parameters such as liquid and vapor velocities, volume ractions, etc., to validate void-quality models such as the Zuber-Findlay Model discussed in class, and to investiate the pressure loss in a two-phase system. Flow Reime Maps Flow reime maps are a means o predictin low reimes based on local system variables. While no universally accepted map has been developed, typically the low patterns are identiied on the basis o liquid and vapor

velocities, volume ractions and densities. A number o low reime maps are available in the literature. An eample o one such map or vertical uplow o air and water is iven in Fiure. The coordinates are liquid and vapor lu (j and j respectively) where the liquid lu is deined as j v and similarly or the vapor lu j v. Fiure : Flow pattern boundaries or vertical uplow o air and water at 15 psia (From Govier and Aziz) Void-Quality Relations It can be shown, that void and quality can be related to the Drit Velocity by 1 1 V 1 G j where V j is a correlated parameter, and enerally a unction o low reime. Given void raction, quality and mass lu, the Drit Velocity is iven by Frictional Pressure Drop V j G 1 1 1 3

In sinle-phase low, rictional losses are correlated in the orm P L D v L G D c c where is the sinle-phase riction actor. It has been observed eperimentally, that in lowin two-phase systems, the pressure drop can be much reater than that in a sinle-phase system with the same mass lu. The classical approach in correlatin two-phase rictional losses is to multiply the equivalent sinle-phase loss by an empirical two-phase multiplier o, P ( ) L D G The simplest model or the two-phase multiplier is the homoeneous model which ives o c 1. o. TWO-PHASE AIR WATER SYSTEM (TEQUILA) The two-phase air water system TEQUILA provides the capability or low reime visualization alon with simultaneous measurements o void raction, liquid velocity, vapor velocity, vapor temperature and pressure drop. From these measurements, the low quality and the total system mass lu can be determined. Flow Reime Visualization: The viewin reion o TEQUILA is a one inch diameter clear pipe. Flow patterns rom bubbly to annular are clearly visible. At hih liquid and vapor velocities, visualization can be enhanced throuh the use o a stroboscope which acts to "reeze" the vapor phase. Liquid Velocity: Liquid velocity is measured directly with a paddle-wheel type low meter placed in the low line prior to the liquid enterin the viewin section. The low meter produces a 4-0 milliamp sinal which can be read directly by the LABTECH Notebook data acquisition hardware and sotware on the SPWRF. Vapor Velocity: Vapor velocity is measured directly by a hot wire anemometer placed in the air line prior to enterin the viewin section. Like the liquid low meter, the anemometer produces a 4-0 milliamp sinal which is read by the SPWRF data acquisition system. Vapor Volume Fraction: Vapor volume raction is measured by use o a amma densitometer. The densitometer relates the vapor volume raction to the attenuation o a collimated photon beam as it passes throuh the viewin section. As air and water have very dierent mass attenuation coeicients, the count rate is a stron unction o the amount o vapor present in the pipe. The void raction can be shown to be related to the count rate, subject to certain assumptions, by ln( C / C ) ln( C / C ) where: C = Count rate or an arbitrary volume raction C = Count rate or all liquid in the pipe ( = 0) C = Count rate or all air in the pipe ( = 1). In a lowin two phase system, the count rate and the void raction at any location are a unction o time and the low reime. In low reimes where the liquid and vapor are uniormly dispersed alon the channel (e.. bubbly and annular) the void raction will be relatively constant with time. In slu low, the void raction in the viewin 4

window o the densitometer will chane siniicantly as the vapor slus pass into view. The averae void raction can be determined by t 1 ( t) dt t0 where the time dependent void raction is obtained rom the time dependent count rate usin the equation above. The time dependent count rate can be obtained directly rom the countin system. Flow Quality: The low quality is deined to be the low raction o vapor in a two phase system, i.e. m m m At steady state, the liquid and vapor low rates in the viewin section are the same as the liquid and vapor low rates measured in the individual low lines. As the cross sectional area o the three low paths are the same, this implies low quality is iven by v v v where the liquid and vapor properties are those measured in their respective low lines. It should be noted, that in an air-water system, the vapor density is much lower than that in a steam-water system, and as a result care must be taken in the selection o liquid and vapor velocities in order to achieve reasonable values o quality. This is illustrated in Fiure 3 below or an air density o 0.076 lbm/t 3. Total System Mass Flu: The mass lu in the viewin section is iven by G m m m v v A A as the cross sectional areas are equal. The liquid and vapor properties are aain measured in their respective low lines. 5

0.1000 Quality 0.0100 v = 100 v = 80 v = 60 v = 40 v = 0 0.0010 v = 10 0.0001 v = 1 0 1 3 4 5 6 7 8 9 10 11 1 13 14 Liquid Velocity (t/sec) Fiure 3: Quality Vs Water and Air Velocity EXPERIMENTAL PROCEDURE: FLOW REGIME MAPPING AND VOID-QUALITY RELATIONS The objective o this laboratory is to study the evolution o two-phase low patterns and develop void-quality relationships or an air-water system. 1) Determine the count rate in the viewin section under zero low conditions or all air and all water in the pipe. ) For constant values o mass lu, measure void raction, liquid velocity and vapor velocity over the ull rane o low conditions. Note the low reime or each measurement (you may wish to record the low patterns photoraphically). Low liquid velocities can be obtained simply by natural circulation. Caution should be taken at hih liquid and vapor lows as vibrations in the pipin system can alter the source-detector eometry or the amma densitometer. 3) Plot low reime versus liquid and vapor lu on the Govier and Aziz map. Compare your results to this map and the Hewitt and Roberts map iven in the reerences (Todreas and Kazimi). Note, at steady state, the liquid mass low rate in the liquid line and the viewin section are equal. The same holds true or the vapor mass low rate. This implies v A v A k k line k k k viewin section where k, indicates the appropriate phase. Since the cross sectional areas are equal, and i we assume the densities are constant, v v j. k line k k viewin section k viewin section 6

4) Plot void raction as a unction o quality and mass lu. You should indicate dierent low reimes with dierent symbols. This will indicate i there is a low reime dependence. Compute the Drit Velocity as a unction o low reime and compare your results to those in the literature. EXPERIMENTAL PROCEDURE: TWO-PHASE PRESSURE FRICTIONAL LOSSES 1) Measure the pressure drop under sinle-phase liquid and sinle phase vapor conditions rom zero velocity to ull low in the horizontal pipin section. ) Measure liquid velocity, vapor velocity and pressure drop over the ull rane o low conditions. Note the low reime or each measurement (you may wish to record the low patterns photoraphically). Low liquid velocities can be obtained simply by natural circulation. Caution should be taken at hih liquid and vapor lows. Note: The pipe diameter in the horizontal section is smaller than that where the liquid and vapor velocities are measure and the proper corrections should be made. 3) Compute and plot the rictional pressure drop as a unction o mass lu or both sinle-phase and two-phase conditions. 4) Compute and plot the two-phase riction multiplier as a unction o quality and mass lu. Note: Compare to the homoeneous multiplier. o P P 1 G 5) Correlate the two phase multiplier in terms o the Martinelli Parameter 0. 1. 18. 7