F E A T U R E S & B E N E F I T S. ED1312R5 Updated May 2011 For latest specs visit

Similar documents
Tremco Fire Protection Systems Group Technical Bulletin

Complete Firestop Systems Guide

Terms and Definitions In Canada

Catalog Number Pillow Type Pillow Size

Excerpts from the Canadian National Building Code (NBC)

FIRESTOPPING. Cable. Firestopping is the technology used to

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Flamesafe Firestopping Products. Firestopping Products.

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Fire Barriers & Fire Stopping

Dropping power and communications neatly and simply from up

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

AWG: Cat5e: Cat6: Cat6A:

FIRESTOPPING & SMOKE SEALS

HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

ONTRAC WIRE MESH CABLE TRAY SYSTEM

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES

Specification SFTP CAT6 Network Cable 23AWG CU

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

9300BC SERIES Light Commercial Door Closer

UT Southwestern Medical Center Information Resources Cable Installation Standard

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Super-Flex Traveling Cable Type ETT/300V

4 Installation Requirements

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

Passive Fire Protection

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

Communication, Signal & Data Cables

Electrical Wiring Technical Bulletin

Meeting Room Solutions

STABILOY BRAND FeeDeR SOLuTIONS

Section Grounding and Bonding for Communications

MANUFACTURER S CERTIFICATE OF COMPLIANCE

STABILOY BRAND FeeDeR SOLuTIONS

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

Generator DoCKInG StatIonS

Introduction to cable fire stopping

TABLE OF CONTENT

GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

800 Communications Circuits

Safely Installing, Maintaining and Inspecting Cable Trays

Position Cat5e (EMT) Modular Plug Connectors. Application Specification

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

HARTING Ethernet Cabling 8-poles Overview

TIA 569 Standards Update Pathways & Spaces. Ignacio Diaz, RCDD April 25, 2012

MOBILE HOME SERVICE REQUIREMENTS GAS

SECTION MORTUARY REFRIGERATORS

RJF TV Ethernet connection system for harsh environment

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Security & Control Cables

The Source of Firestop Expertise SM

Quick Connect Boxes Inside Gloveboxes

National Archives and Records Administration (NARA) Facility Standards for Federal Records Storage Facilities

GENERAL ELECTRICAL REQUIREMENTS

GUARDRAIL POST STEEL

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

SECTION 22 LIGHTNING PROTECTION SYSTEM

COAXICON Contacts. RF Coax Connectors. Product Facts

Basic Fire Door Requirements

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

PART 1 GENERAL 1.1 SECTION INCLUDES

Copper Cabling Infrastructure Offering

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

Build for Tomorrow. Today.

Power Commander Power Distribution Units from Wiremold/Legrand offer

Packaged Terminal Air Conditioner Wall Sleeve Installation

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

AMPSEAL* Automotive Plug Connector and Header Assembly

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Requirements for Electrical Installations

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Transcription:

FlameStopper Thru-Wall/Floor Fittings FS Series Thru-Wall/Floor Fittings for New & Retrofit Fire Wall/Floor Applications Wiremold FlameStopper Thru-Wall/Floor Fittings have been redesigned to provide firestopping solutions for both new and retrofit applications. Flamestopper Thru-Wall/Floor Fittings provide installers with a variety of UL Classified ready-touse options for transitioning cables through firewalls and floors to ensure that the integrity of the fire rating is maintained. These fittings have been tested by Underwriters Laboratories Inc. to ASTM E814 UL1479, Fire Tests of Through- Penetration Firestops. The Flamestopper Thru- Wall/Floor Fittings offer a passive fire and life safety system with ratings up to four hours (with or without cables installed) to complement existing sprinkler systems and up to three hours for through floor applications. FlameStopper Thru-Wall/Floor Fittings make it easy to add cables and maintain the UL rating. F E A T U R E S & B E N E F I T S n Designed for use in either new or retrofit applications. With the use of retrofit kit, Flamestopper can be used to provide firestopping to existing through-wall/floors cable penetrations or for new installations. n Classified to U.S. and Canadian safety standards by Underwriters Laboratories Inc. for use in throughpenetration firestop systems only. Up to four-hour F and T ratings ensures product will maintain the integrity of fire rated walls or floors whether empty, partially filled or fully loaded. See chart on back page or UL Fire Resistance Directory (link provided on Wiremold website) for ratings with specific cables. n Low air (smoke) leakage. UL tested with L Ratings from 1.9 to 5.9 cfm (cubic feet per minute). n Plenum rated. Tested to UL 2043 and determined to be suitable for air handling spaces (plenums). n Built-in Firestopping expands with exposure to heat. Engineered for rapid expansion when exposed to fire or high temperatures to quickly seal the pathway and prevent the passage of flames and smoke. n Clean, professional installation. Appeals to owners, tenants, and inspection authorities. n Easy to inspect. FlameStopper Thru-Wall/Floor Fittings are offered standard in a bright, easy-to-identify powder coat red or G90 finish complete with preprinted label for the installer to fill out prior to inspection approval. From installation to full cable load, the fitting remains firestopped and compliant. n Easy to add or remove cables. Simply adjust the doors to accommodate cables as desired without the need to remove, add, or adjust firestopping intumescent materials. n Retrofit kit for existing installations. A split conduit for installations where no conduit is installed, large firestopped wall plate for irregular hole penetrations, and a heat shield for existing extended conduit lengths, allow for firestopping virtually any existing condition without the need for repudding with firestop material after installation. n Mechanical doors provide steel barrier between rooms. Fittings may be pre-installed for anticipated future cabling requirements. Fire ratings are preserved while doors remain closed to block off the opening until cables are installed. n Use with any wall thickness. Fittings are shipped in pairs and installed on both sides of a wall fitted with a 2" or 4" piece of trade size EMT conduit. n Use with concrete floor with minimum of 4 1/2" [114mm] depth. Designed for use with SpecMate and Cablofil brand cable trays as well as other Wiremold pathways. See the Wiremold website at www.legrand.us/wiremold for details. For custom options, please consult the factory. ED1312R5 Updated May 2011 For latest specs visit www.legrand.us/wiremold

Catalog No./Item FlameStopper Thru-Wall/Floor Fitting Ordering Information Description/Specifications Catalog No./Item Description/Specifications I I FS4R-RED FS4R-GA 6 1/4" [159mm] FS2R-RED FS2R-GA 3 3/4" [95mm] 6" [153mm] 1 3/4" [44mm] 3 5/8" [92mm] FSPCC4758 7 5/8" [194mm] Firestop 4" Trade EMT Conduit Fitting For transitioning cable through fire rated walls/floors for both new and retrofit applications. Available in red (RED), or G90 galvanized finish (GA). UL System W-L-3264 and W-J-3137. Firestop 2" Trade EMT Conduit Fitting For transitioning cable through fire rated walls/floors for both new and retrofit applications. Available in red (RED), or G90 galvanized finish (GA). UL System W-L-3264 and W-J-3137. 1 3/4" [44mm] Precut Conduit 4" Trade Size EMT Precut to 7 5/8" [194mm] to fit standard gypsum fire walls with a two-hour fire rating (6" [152mm] wall thickness). I FS4RHS FS2RHS FS4RWP12 6 1/8" [155mm] 6 3/8" [162mm] 6 3/8" [162mm] 3 3/4" [95mm] 10" [254mm] 12" [305mm] 12" [305mm] Heat Shield 4" Trade Size Conduit Used only when an existing installed conduit extends 1" [25mm] to 6" [152mm] beyond the wall surface. Heat Shield 2" Trade Size Conduit Used only when an existing installed conduit extends 1" [25mm] to 6" [152mm] beyond the wall surface. Retrofit Kit for Existing Installations Kit includes 4" trade size split conduit sleeve to enclose existing cables, and 12" x 12" [305mm x 305mm] ceramic heat protected wall plate to cover irregular hole cuts. For use with FS4R Series Firestop. FSPCC2758 7 5/8" [194mm] Precut Conduit 2" Trade Size EMT Precut to 7 5/8" [194mm] to fit standard gypsum fire walls with a two-hour fire rating (6" [152mm] wall thickness). FS2RWP8 10" [254mm] 8" [203mm] 8" [203mm] Retrofit Kit for Existing Installations Kit includes 2" trade size split conduit sleeve to enclose existing cables, and 8" x 8" [203mm x 203mm] ceramic heat protected wall plate to cover irregular hole cuts. For use with FS2R Series Firestop. SPMGL 7/8" [22.2mm] 1 1/2" Ortronics [38mm] Series II 5/8" [15.9mm] Grounding Lug For use with SpecMate or Cablofil brand cable trays to provide ground continuity. Electroplated aluminum. Dual rated for copper and aluminum conductors, No. 2 to 14 gage cable. WBSBC 1 3/8" [35mm] Split Bolt Connector For use with Cablofil brand wire basket trays to provide ground continuity. Electroplated aluminum. Dual rated for copper and aluminum conductors, No. 2 to 8 gage cable. The FlameStopper Thru-Wall/Floor Fitting consists of two box assemblies with adjustable steel doors that attach to EMT conduit. Intumescent firestopping material is factory installed and no other firestopping material is required. 2

FlameStopper Thru-Wall Fitting Installation Outline For New Construction Installing a FlameStopper Thru-Wall Fitting is easy and straightforward. 1. Determine location and cut hole in wall using a hole saw, keyhole saw or a core drill. 2. Insert the appropriate length of conduit into the opening. NOTE: Consider using a level to ensure the box is square and hold base in place with 2 screws. 3. Place the FlameStopper Thru-wall Fitting Box over the opening and secure the two bolts. Wall labels, provided in a bright yellow color and shown below the installed fitting, are easy for inspectors to locate and review. 1. Cut (if after concrete pour) or form (if pre-pour) a 2" or 4" [51mm or 102mm] opening. FlameStopper Thru-Floor Fitting Installation 2. Insert the appropriate length of conduit into the opening. CAUTION: Conduit should not extend more than 1" [25mm] above or below the floor hole opening. 3. Place the FlameStopper Thru-floor Fitting Box over the opening and secure the two bolts. 3

FlameStopper Thru-Wall Fitting Installation Outline For Retrofit Applications Retrofit Example #1: 1. Existing conduit with cables. Remove firestop putty. 2. Attach FlameStopper box to existing conduit and attach heat shield. 3. Finished assembly. NOTE: If existing conduit extends out from wall less than 7/8" [22.2mm], no heat shield is required. Retrofit Example #2: 1. Existing hole with cables. Irregular hole cut. 2. Attach ceramic heat protected wall plate to cover irregular hole cut. Insert split conduit around existing cables. 3. Push split conduit into wall. 4. Screw wall plate to conduit to complete assembly. 5. Attach FlameStopper box to split conduit. 4

FlameStopper Thru-Wall Fitting UL Ratings Flame: Temperature: Air Leakage: The F Rating (F and FH in Canada) is expressed in hours. This number indicates the specific length of time that a barrier can withstand fire before being consumed or before permitting the passage of flame through the opening. The T Rating (FT and FTH in Canada) is expressed in hours. This number indicates the length of time that the temperature on the non-fire side of the penetration does not exceed 325 degrees F above the ambient temperature. The L Rating is expressed in CFM. This number indicates the amount of air (or cold smoke) that can leak through a penetration. THROUGH-WALL RATINGS FOR FS2R & FS4R SERIES (When used alone for new construction or existing construction with heat shield.) UL RATINGS (US Ratings) UL RATINGS (Canadian Ratings) F Rating w/ & w/o cables T Rating w/coax cable T Rating w/fiber optic cable T Rating w/max. 1" fiber optic rcwy. w/fiber optic fill T Rating w/max. 4-pair cable (22 ga & smaller) T Rating w/max. 4 conductor (2AWG & smaller) T Rating w/max. 100-pair cable (24 ga & smaller) T Rating w/max. 400-pair cable (24 ga & smaller) T Rating w/mc cable (8 wire max. 12 ga & smaller) L Rating at ambient w/o cables (doors closed) L Rating at 400 F w/o cables (doors closed) L Rating at ambient with cables L Rating at 400 F with cables Suitable for use in air handling spaces (plenums) 1 Hour 1 Hour 45 Minutes 15 Minutes 2.6 cfm 1.9 cfm 2.8 cfm 1.3 cfm Yes F & FH Rating w/ & w/o cables FT & FTH Rating w/coax cable FT & FTH Rating w/fiber optic cable FT & FTH Rating w/max. 1" fiber optic rcwy. w/fiber optic fill FT & FTH Rating w/max. 4-pair cable (22 ga & smaller) FT & FTH Rating w/max. 4 conductor (2AWG & smaller) 1 Hour FT & FTH Rating w/max. 100-pair cable (24 ga & smaller) 1 Hour FT & FTH Rating w/max. 400-pair cable (24 ga & smaller) 45 Minutes FT & FTH Rating w/mc cable (8 wire max. 12 ga & smaller) 15 Minutes L Rating at ambient w/o cables (doors closed) 2.6 cfm L Rating at 400 F w/o cables (doors closed) 1.9 cfm L Rating at ambient with cables 2.8 cfm L Rating at 400 F with cables 1.3 cfm Suitable for use in air handling spaces (plenums) Yes THROUGH-WALL RATINGS FOR FS2R & FS4R SERIES (When used with wall plate for retrofit applications.) UL RATINGS (US Ratings) UL RATINGS (Canadian Ratings) F Rating w/ & w/o cables T Rating w/max. 4-pair cable (22 ga & smaller) T Rating w/coax cable T Rating w/fiber optic cable T Rating w/max. 1" fiber optic rcwy. w/fiber optic fill T Rating w/mc cable (8 wire max. 12 ga & smaller) L Rating at ambient w/o cables (doors closed) L Rating at 400 F w/o cables (doors closed) L Rating at ambient with cables L Rating at 400 F with cables Suitable for use in air handling spaces (plenums) 2 Hours 1.25 Hours 1 Hour 1.25 Hours 1.25 Hours 15 Minutes 1.7 cfm 1.8 cfm 3.3 cfm 2.0 cfm Yes F & FH Rating w/ & w/o cables 2 Hours FT & FTH Rating w/max. 4-pair cable (22 ga & smaller) 1.25 Hours FT & FTH Rating w/coax cable 1 Hour FT & FTH Rating w/fiber optic cable 1.25 Hours FT & FTH Rating w/max. 1" fiber optic rcwy. w/fiber optic fill 1.25 Hours FT & FTH Rating w/mc cable (8 wire max. 12 ga & smaller) 15 Minutes L Rating at ambient w/o cables (doors closed) 2.6 cfm L Rating at 400 F w/o cables (doors closed) 1.9 cfm L Rating at ambient with cables 2.8 cfm L Rating at 400 F with cables 1.3 cfm Suitable for use in air handling spaces (plenums) Yes 5

FlameStopper Thru-Floor Fitting UL Ratings Flame: Temperature: Air Leakage: The F Rating (F and FH in Canada) is expressed in hours. This number indicates the specific length of time that a barrier can withstand fire before being consumed or before permitting the passage of flame through the opening. The T Rating (FT and FTH in Canada) is expressed in hours. This number indicates the length of time that the temperature on the non-fire side of the penetration does not exceed 325 degrees F above the ambient temperature. The L Rating is expressed in CFM. This number indicates the amount of air (or cold smoke) that can leak through a penetration. THROUGH-FLOOR RATINGS FOR FS2R & FS4R SERIES (When used alone.) UL RATINGS (US Ratings) UL RATINGS (Canadian Ratings) F Rating w/ & w/o cables F Rating w/ & w/o cables T Rating w/o cables T Rating w/o cables T Rating w/coax cable 3 Hour T Rating w/coax cable 3 Hour T Rating w/fiber optic cable T Rating w/fiber optic cable T Rating w/max. 4-pair cables (22 ga. or smaller) T Rating w/max. 4-pair cables (22 ga. or smaller) T Rating w/max. 4-conductor (2 ga. or smaller) 45 Minutes T Rating w/max. 4-conductor (2 ga. or smaller) 45 Minutes T Rating w/max. 100-pair cables (24 ga. or smaller) 1 Hour T Rating w/max. 100-pair cables (24 ga. or smaller) 1 Hour T Rating w/max. 400-pair cables (24 ga. or smaller) 45 Minutes T Rating w/max. 400-pair cables (24 ga. or smaller) 45 Minutes T Rating w/mc cable (8 wire Max. 12 ga. or smaller) 15 Minutes T Rating w/mc cable (8 wire Max. 12 ga. or smaller) 15 Minutes L Rating at ambient w/o cables (doors closed) 2.6 cfm L Rating at ambient w/o cables (doors closed) 2.6 cfm L Rating at 400 F w/o cables (doors closed) 1.9 cfm L Rating at 400 F w/o cables (doors closed) 1.9 cfm L Rating at ambient with cables 2.8 cfm L Rating at ambient with cables 2.8 cfm L Rating at 400 F with cables 1.3 cfm L Rating at 400 F with cables 1.3 cfm Suitable for use in air handling spaces (plenums) Yes Suitable for use in air handling spaces (plenums) Yes NOTE: Minimum 4 1/2" [114mm] thick reinforced lightweight or normal weight (100-150 pcf) [1600-2400 kg/m3] concrete floor. Maximum diameter of opening is 4 1/2" [114mm]. 6

FlameStopper Thru-Wall/Floor Fitting Wire Fill Capacity Charts Flamestopper Wire Fill Capacities for Power Wiring CABLE O.D. FS2 FS4 TYPE Inches [mm] Maximum Fill Maximum Fill Max 4 cond. No. 2 AWG 0.375 [9.5] 18 80 (or Smaller) copper 0.500 [12.7] 10 45 conductor cable with 0.625 [15.9] 6 28 XLPE/PVX insulation 0.750 [19.1] 4 20 and PVC jacket 0.875 [22.2] 3 14 1.000 [25.4] 2 11 1.125 [28.6] 2 8 Max 8 cond. No. 12 AWG 0.375 [9.5] 118 80 MC (Metal Clad) cable 0.500 [12.7] 10 45 0.625 [15.9] 6 28 0.655 [16.6] 5 26 Flamestopper Wire Fill Capacities for Data/Communications CABLE/WIRE SIZE O.D. FS2 FS4 Inches [mm] Maximum Fill Maximum Fill UNSHIELDED 4-pair, 24 AWG Cat 3 UTP 0.190 [4.8] 71 312 TWISTED PAIR 4-pair, 24 AWG Cat. 5e UTP 0.210 [5.3] 58 255 4-pair, 24 AWG Cat. 6 UTP 0.250 [6.3] 41 180 TELEPHONE 2-pair, 24 AWG 0.140 [3.6] 130 574 25-pair, 24 AWG 0.410 [10.4] 15 67 50-pair, 24 AWG 0.580 [14.7] 7 33 100-pair, 24 AWG 0.700 [17.8] 5 22 400-pair, 24 AWG 1.470 [37.3] 1 5 COAXIAL RG58/U 0.195 [5.0] 197 296 RG59/U 0.242 [6.1] 43 192 RG62/U 0.242 [6.1] 43 192 RG6/U 0.270 [6.9] 32 140 FIBER OPTIC 2 Count 0.180 [4.6] 79 347 6 Count 0.210 [5.3] 58 255 24 Count 0.400 [10.2] 16 70 48 Count 0.450 [11.4] 12 55 96 Count 0.560 [14.2] 8 35 7

N O T E S WIREMOLD U.S. and International: 60 Woodlawn Street West Hartford, CT 06110 1-800-621-0049 FAX 860-232-2062 Outside U.S. 860-233-6251 Canada: 570 Applewood Crescent Vaughan, Ontario L4K 4B4 1-800-723-5175 FAX 905-738-9721 Copyright 2011 Legrand All Rights Reserved ED1312R5 Updated April 2011 For latest specs visit www.legrand.us/wiremold