Transfomation of SEM into TEM without any atachment or remodel! Yoshinori Muranaka & Isao Ohta

Similar documents
Ion Beam Sputtering: Practical Applications to Electron Microscopy

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Name: Due: September 21 st Physics 7230 Laboratory 3: High Resolution SEM Imaging

ISOLATION AND PROPERTIES OF SECRETORY GRANULES FROM RAT ISLETS OF LANGERHANS. II. Ultrastructure of the Beta Granule

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts

The microscope is an important tool.

Polarization of Light

Microscopes and the Metric System

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Mass production, R&D Failure analysis. Fault site pin-pointing (EM, OBIRCH, FIB, etc. ) Bottleneck Physical science analysis (SEM, TEM, Auger, etc.

View of ΣIGMA TM (Ref. 1)

The Basics of Scanning Electron Microscopy

Lenses and Apertures of A TEM

Electron Microscopy SEM and TEM

Forensic Science: The Basics. Microscopy

Looking through the fish-eye the Electron Ronchigram. Duncan T.L. Alexander CIME seminar May 24, 2012

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

Scanning Electron Microscopy: an overview on application and perspective

Cells, tissues and organs

Comparing Plant and Animal Cells

CSCI 4974 / 6974 Hardware Reverse Engineering. Lecture 8: Microscopy and Imaging

Microscopy and Cellular Morphology

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts

Development of High Speed Oblique X-ray CT System for Printed Circuit Board

SILA Sistema Integrato di Laboratori per l Ambiente. CENTRE FOR MICROSCOPY AND MICROANALYSIS Scientific coordinator: Prof.ssa Rosanna De Rosa

Structure of the Kidney Laboratory Exercise 56

Abrasive-Flow Machining

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

Experiment 3 Lenses and Images

Principles of Ion Implant

FTIR Measurement Data Storage and Control Thin Film Sample Measurement Methods and Precautions ---5 Question ---8

Software-based three dimensional reconstructions and enhancements of focal depth in microphotographic images

VICKERS HARDNESS TESTER. HBS HBW Kc

Calibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft

Microscope Lab Introduction to the Microscope Lab Activity

MALARIA PARASITE COUNTING

Scanning Electron Microscopy Primer

An Overview of Cells and Cell Research

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

7. advanced SEM. Latest generation of SEM SEM

Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications

Physics 441/2: Transmission Electron Microscope

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

Lateral Resolution of EDX Analysis with Low Acceleration Voltage SEM

Coating Technology: Evaporation Vs Sputtering

Care and Use of the Compound Microscope

CELERY LAB - Structure and Function of a Plant

Exercise 2. The Compound Light Microscope

Applications of confocal fluorescence microscopy in biological sciences

Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light

Diffractive Optical Elements (DOE) for FLEXPOINT Laser Modules

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

DualBeam Solutions for Electrical Nanoprobing

The Science of Biology

CHAPTER D1 ION OPTICS OF MAGNETIC/ELECTRIC SECTOR MS

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

INTRODUCTION TO THE XL30-FEG SEM. 1.1 The mouse The monitor. Figure THE USER INTERFACE

Theremino System Theremino Spectrometer Technology

KS-70. Catheterization Table GENERAL

CELERY LAB - Structure and Function of a Plant

Lab Exercise 4. Epithelial Tissues. Connective Tissue Proper. What you need to be able to do on the exam after completing this lab exercise:

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Chapter 7: The Nervous System

X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION

Hole s Human Anatomy and Physiology Eleventh Edition. Mrs. Hummer Hanover Area Jr./Sr. High School. Chapter 1 Introduction to Anatomy and Physiology

Usage of AFM, SEM and TEM for the research of carbon nanotubes

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

Chapter 22: Electric motors and electromagnetic induction

The Olympus stereology system. The Computer Assisted Stereological Toolbox

GEOMATICS & VOCABULARY

Introduction to microstructure

Viruses. Viral components: Capsid. Chapter 10: Viruses. Viral components: Nucleic Acid. Viral components: Envelope

Compound microscope (Hund)

SAMPLE TEST PAPER - I

SEM Analysis of CO 2 Laser Treated Cotton Grey Fabric

Super Cool Sputter Coater

Optical mesoscopy with a new giant lens. Gail McConnell, Johanna Tragardh, John Dempster & Brad Amos

Scanning Surface Inspection System with Defect-review SEM and Analysis System Solutions

Genetic material of all living organisms. Biology - 100

Improvement of control cable system of trans-humeral body-powered prostheses

University of California at Santa Cruz Electrical Engineering Department EE-145L: Properties of Materials Laboratory

Light and its effects

North Bergen School District Benchmarks

Tuesday 20 May 2014 Morning

The Bonelle Tool and Cutter Grinder

Scanning Electron Microscopy tools for material characterization

TopSky DLG Installation Manual

26/06/2011. Electron Microscopy: TEM, Immunogold Labeling, SEM, Correlative Microscopy

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

LIFE SCIENCE I TECHNICAL BULLETIN ISSUE N 11 /JULY 2008

The crime scene sketch is an invaluable aid in recording

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

Sample preparation for X-ray fluorescence analysis

Atomic Force Microscopy. Long Phan Nanotechnology Summer Series May 15, 2013

Atomic Force Microscopy Observation and Characterization of a CD Stamper, Lycopodium Spores, and Step-Height Standard Diffraction Grating

BAL-TEC SCD 005. Scientist in charge: Lhoussaine Belkoura 07/14/06. softcomp soft matter composites 1

Keystone Review Practice Test Module A Cells and Cell Processes. 1. Which characteristic is shared by all prokaryotes and eukaryotes?

Transcription:

Transfomation of SEM into TEM without any atachment or remodel! Development and evaluation of specimen holder of scanning electron microscope for observation of transmitted ultra-thin sections by secondary electron image Yoshinori Muranaka & Isao Ohta Research Equipment Center, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu. 431-3192 Japan

Summary We developed and evaluated the special specimen holder of scanning electron microscope (SEM) to observe the transmitted electron images of ultra-thin section for transmitted electron microscope (TEM) by secondary electron of SEM without any attachments or remodels. The specimen holder made of aluminum or carbon is equipped with the grid stage, the plate for generation of secondary electron and the objective aperture. Whole grid areas can be easily observed by the functions of tilting and rotation. By the holder, the quality of secondary images of TEM specimens by the field emission SEM was comparable to that of TEM images. Moreover, developed holder is useful for observation of the backscatter electron image and X-ray element analysis in the section. Introduction There are SEM and TEM for an electron microscope. The former observes the surface of the bulk-shaped sample, and the latter is for transmitted image observation of the film-shape sample such as ultra-thin section. An observational purpose and the shape of the sample differ each. We tried to develop a special specimen holder of SEM that can be used for an observation of transmitted electron images of ultra-thin section for TEM by secondary electron of SEM 1) (fig. 1). The advantages of the scanning transmitted image are easily adjusting contrast and fewness of the sample damages 2). Scanning transmitted image may be able to be observed by an attached scanning transmitted electron detector. However, this device is not common because of a high price. Requirements of developments Requirements for the holder were as follows. (1) SEM images can be observed by the secondary electron detector. (2) Whole area of specimen grids for TEM can be observed as secondary electron images in any SEM. (3) Resolution of the images should keep that of SEM. Resolution of the images by field emission SEM should be comparable to that by conventional TEM, and resolution of the images by small desktop-type SEM should be high enough to use for clinical diagnosis. (4) Any types of specimen for TEM observations, such as ultra-thin sections, negative stained materials and replica membranes, should be applicable. (5) Backscatter electron images and X-ray element analysis can be obtained by SEM equipped with a each detector for backscatter electron or X-ray. Fig.1 The comparison of the principal between general SEM observation and transmission secondary electron image observation. Left: general SEM specifications to observe a bulk sample. Right: specifications to observe a transmission secondary electron image for ultra-thin section. Specifications of developped sample holder The development holder became the following structure according to a developmental requirements (fig. 2). (1) The main body was made by duralumin, and the analysis specifications use carbon for a part. The size of the main body were 10 mm in diameter and 15 mm in height to load it to the sample stage of various SEM. (2) A hole of 3 mm in diameter was drilled on the top surface of main body for fixing a sample grid and locking mechanism. (3) The aspect to convert a transmitted electron beam into a secondary electron was duralumin abrasion side of horizontal angle 60 degrees. (4) A objective aperture disk made of molybdenum was loaded in the holder for highly resolving power and ratio of S/N. The aperture size prepared from 60 µm in diameter for high magnification to 300 µm in diameter for wide view. (5) Objective areas were removed roughly by using the function of incline and revolving system in SEM (fig. 3) and tuned in exactly by original X-Y movement of the specimen stage. Results The development holder wsa tried out and showed the Fig.2 Upper drawing and photograph of the developed sample holder, grid mesh and locking ling. Left drawing is locking structure.

following results, the functionality, the applied nature and performance. (1) The specimen grid could be kept horizontally on the upper surface of the specimen holder without specimen drift. Magnetic grids, such as nickel grid could be also kept stably by fastening a holding key (fig. 4). (2) Objective areas could be easily and smoothly observed by using the function of incline and revolving in SEM (fig. 2 and fig. 5). (3) Resolution and image quality under an observation by high resolution SEM such as field emission SEM were comparable to that by TEM when maximum accelerating voltage in SEM and high beam current were used. Transmitted secondary electron images of various cellular organelles from the ultra-thin sections could be seen (fig. 6 and fig. 7). When the TEM images at the same sites were compared with the transmitted secondary electron images in SEM by applying the developed holder, the both images at the same site were almost the same quality in any magnifications (fig. 8). Furthermore, resolution of the scanning transmitted secondary electron image by the small SEM of the desktop type is enough for the use of the clinical diagnosis such as membraneous nephritis from kidney biopsy (fig. 9). (4) Transmitted secondary electron images could be obtained also from other membrane-type specimens, such as replica membrane, negative stain with virus and thinning materials as the ultra-thin sections by using the developed holder (fig. 10). (5) Both transmitted secondary electron image and backscatter electron image could be conveniently observed in the ultra-thin sections labeled with colloidal gold for immunoelectron microscopy. TEM cannot provide this function, so this is one of the unique characteristics (fig. 11). (6) To effectively increase the detection of X-ray from the membrane-type specimens and to avoid production of X-ray surround the specimen, the holder for X-ray element analysis was developed, and some parts of that was made of carbon (fig. 12). If the new holder is used, a X-ray analysis is enabled in Fig.3 A moving the objective area into the objective aperture by using the function of incline and revolving system in SEM. Fig.4 Whole (left) and top surface (right) view of the developed sample holder loaded grid mesh and locking ling Fig.5 Grid images under the search for objective area in ultra-thin section Left: The aperture at center of grid. Middle: Movement of aperture for objective area. Right: Enlargement objective area. both the bulk and the film by a expensive analyzer just installed to SEM. Conclusions With the developed holder, transmitted secondary electron images can be obtained from any thin-membrane type specimen, moreover, the observation of backscatter electron images and X-ray element analysis are available. There are far many numbers of SEM than TEM in universities, institutes, hospitals and high schools. Observation of TEM images would be also to do at Fig.6 Transmitted-secondary electron images of ultra-thin section in rat liver by SEM Left shows whole image of liver cell at x4,000 and right is enlarged image at x200,000

Fig.7 Transmitted secondary electron images of ultra-thin section in rat small intestine and medulla oblongata by SEM Left shows the cross section image of microvilli magnified at x300,000, middle hows cross section image of myelin magnified at x200,000, and right is longitudinal section image of rat skeletal muscle magnified at x200,000 Fig.8 The comparison of TEM images of rat liver at the same sites of the same section with the transmitted secondary electron images by SEM using the dveloped sample holder. Upper line is TEM images and lower line is the transmitted secondary electron images. The magnification is x10,000, x50,000 and x100,000 from the left. The differences are not observed in each magnification in a clearness and resolution. Fig.9 Application to the clinical diagnosis by observing ultra-thin section using small SEM. Left image shows CarryScope (JCM-5100; JEOL, Tokyo Japan) which is small desk top SEM. Middle image shows canning transmitted secondary image of the glomerulus from human kidney biopsy specimen by CarryScope with the developed holder. Light is enlarged image of the part which is surrounded by white square in the glomerulus, and immune complex as are located in the basement membrane (arrows).

seminars of electron microscopy for engineer, and classes for boys and girls if SEM cloud have a function of TEM (fig. 13). There are a small number of TEM in the developing countries, our developed holder would provide great opportunity to observe TEM images of virus and bacteria in SEM (fig. 14). References [1] E. Oho, T. Sasaki, K. Adachi, Y. Muranaka and K. Kanaya; An inexpensive and highly efficient device for observing a transmitted electron image in SEM; J. Electron Microsc. Technique. 5. (1987) p. 51-58. [2] Y. Muranaka, M. Hakamata, I. Ohta, E. Oho and K. Kanaya. STEM utilization for the better observation of biological specimens; J. Clinical Fig.10 Transmitted secondary electron image of HBs virus on the thin film Electron Microsco. 19, (1986) p. 395-396. stained by the negative stain meythod with uranyl acetate by using the developed holder. Direct magnified is x100,000. Fig.11 The observation of ultra-thin section for immune-electron microscopy with transmitted image and backscatter electron image by SEM. An external secretion cell of the rat pancreas labeled by colloidal gold of 10 nm in diameter. Left image is scanning transmitted secondary electron image and right image is backscatter electron image. Direct magnified were 50,000. Fig.12 Special specifications holder for X-ray analysis and a result of analysis for ultra-thin section. Left drawing and center photograph shows special specifications holder for X-ray analysis. A part of the incident electron irradiation is made of carbon. Right graph is energy spectrum of X-ray element analysis by SEM at the field indicated by arrow in the ultra-thin section.

Fig.13 The class of a microscope or nature observation for children where only SEM could be brought in for TEM observation. Left photograph is the class of natural observation for children in National Olympics Memorial Youth Center in 2006 and right is a seminars of electron microscopy for engineer in 2007. Fig.14 The request from an anti-infectious disease measure of the developing country Upper line images are bird influenza virus type H5N1 infected with human in Vietnam and cultured in the Vero cell. Left image is many virus budding off from kidney cell of african green monkey kidney origin. Middle is enlarge image of budding virus. Right is more enlarged image of virus by SEM with the developed holder. Direct magnified is x500,000. Lower line images are a kind of the cigarette mosaic virus infected with a fruit and the leavies of the papaya. Left and middle are leavies and fruit. Right is TEM image of a kind of the cigarette mosaic virus stained by negative stain method with uranyl acetate. Author; Yoshinori Muranaka, Ph.D. Laboratory for Ultrastructure Research, Research Equipment Center, Hamamatsu University School of Medicine. 1-20-1 Handayama, Higashi-ku, Hamamatsu, 431-3192 JAPAN Tel & Fax; 053-435-2342, Mobile phone; 090-3307-3489, E-Mail; muranaka@hama-med.ac.jp