1 Compound microscope (Hund) ) Eyepieces (magnifies 10x), one with diopter adjustment, 2) Interp[upillary adjustment, 3) Head, 4) Revolving nosepiece, 5) Objectives (magnifies 4, 10, 40x, or 100x), 6) Slide holder, 7) Stage, 8) Iris diaphragm adjustment knob, 9) Light condenser, 10) Blue filter holder, 11) Condenser height adjustment knob, 12) Light source opening, 13) Field diaphragm adjustment, 14) Base, 15) Eyepiece diopter adjustment, 16) Stand, 17) Stage movement knobs, 18) Coarse focus knob, 19) Fine focus knob, 20) Light on/off switch & brightness
2 Compound microscope (Motic) ) Eyepieces (magnifies 10x) diopter adjustment, 2) Interpupillary adjustment, 3) Head, 4) Revolving nosepiece, 5) Objectives (magnify 4x, 10x, 20x, 40x, or 100x), 6) Slide holder, 7) Stage, 8) Iris diaphragm adjustment knob, 9) Light condenser, phase contrast see below, 10) Condenser height adjustment knob, 11) Field diaphragm adjustment, 12) Stand, 13) Light on/off switch, 14) Light intensity knob, 15) Stage movement knobs, 16) Fine focus knob, 17) Course focus knob, 18) Base
3 The Motic microscope (room 1660) is very similar to the Hund microscope (room 1325) except that they are equipped with a phase contrast condenser. It is important the condenser turret be set at BF for Bright Field or the number setting corresponding to the objective in use to get phase contrast effects. When done, please remove slide, return the turret to BF, and put the 4X objective back in place. Phase contrast works great for small cells or unstained or very thin sections
4 Leave dust cover in cabinet Lift microscope with one hand on base, other on stand Gently set microscope down on counter Plug in, turn on and adjust light intensity about half way Open field and iris diaphragm about half way Put the red coded 4x objective in place (gives 40x magnification) Put slide on stage using clip holder Condenser should be just below stage (arrow on knob pointing up for Motics) Move stage using knobs so light shines through specimen Eyepieces diopter set at 0 for Motic or 65 for Hund (line up number with white line) Set eyepiece distance between for your eyes Look though eyepiece and focus on specimen using course focus knob Turn revolving nose piece to yellow coded 10X objective to give 100x magn. Use fine focus, turn to 40X objective (400x magn.) and fine focus as necessary Turn off light, unplug cord but please do NOT wrap it around microscope Put microscope back in same cabinet with the same dust cover on Set-up and care
5 Step 1 (same as when using the dissection microscope): Measure two points on your drawing with the ruler from your student drawer. Make a horizontal line the same length beside the word Scale:. Step 2: Look at the actual specimen through the microscope and, using the ruler (ocular micrometer) in the right eyepiece, count the number of eyepiece divisions (epd) across same two points (this eyepiece ruler has no units - there are simply 100 eyepiece divisions on it). Multiply the epd by the corresponding number of micrometers given in the table below depending on which objective is in use to determine the width or length of the specimen in micrometers: Objective Magnification 1 epd = 4X x40 25 µm 10X x µm 20X * x µm 40X x µm 100X x µm Example: view & draw a happy plant cell: Step 1: Draw a line beside the word Scale: the same width as you drew the cell: Scale: Step 2: Measure the actual cell width using eyepiece ruler. Multiply the number of eyepiece divisions by the number of micrometers that correspond to the objective in use e.g. using 10X objective: 4 epd x 10 µm = 40 µm Indicate scale beside drawing as: Scale: 40 µm Note: This calibration was accomplished using a stage micrometer ruler 1 mm long divided into 0.01 mm (= 10 µm) markings mounted on a slide. * 20X objectives found on Motic scopes only and not all Hund scopes have x1000 Determination of scale using compound microscope
Care and Use of the Compound Microscope
Revised Fall 2011 Care and Use of the Compound Microscope Objectives After completing this lab students should be able to 1. properly clean and carry a compound and dissecting microscope. 2. focus a specimen
MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.
MICROSCOPY I. OBJECTIVES To demonstrate skill in the proper utilization of a light microscope. To demonstrate skill in the use of ocular and stage micrometers for measurements of cell size. To recognize
MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL
Introduction With your purchase of an MT-30/MT-90 series type microscope you have chosen for a quality product. The MT-30/MT-90 series type microscopes are developed for use at schools and laboratories.
EXPERIMENT #1: MICROSCOPY
EXPERIMENT #1: MICROSCOPY Brightfield Compound Light Microscope The light microscope is an important tool in the study of microorganisms. The compound light microscope uses visible light to directly illuminate
Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure
Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure The Microscope: A Tool of the Scientist You may refer to pages 66-67, 72-73 in your textbook for a general discussion of microscopes.
MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY
MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY Adapted from Foundations of Biology I; Lab 6 Introduction to Microscopy Dr. John Robertson, Westminster College Biology Department,
Microscope Lab Introduction to the Microscope Lab Activity
Microscope Lab Introduction to the Microscope Lab Activity Wendy Kim 3B 24 Sep 2010 http://www.mainsgate.com/spacebio/modules/gs_resource/ CellDivisionMetaphase.jpeg 1 Introduction Microscope is a tool
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODELS 156, 156-S, 157 COMPOUND BIOLOGICAL MICROSCOPES
How To Use An Asbestos Microscope
Asbestos Microscopes and Accessories Pyser-SGI has been supplying microscopes and accessories into Asbestos Laboratories for over 40 years PS12 Stage Micrometer with UKAS Certificate of Calibration - For
THE COMPOUND MICROSCOPE
THE COMPOUND MICROSCOPE In microbiology, the microscope plays an important role in allowing us to see tiny objects that are normally invisible to the naked eye. It is essential for students to learn how
Exercise 2. The Compound Light Microscope
6 Exercise 2 The Compound Light Microscope INTRODUCTION: Student Learning Objectives: After completing this exercise students will: a. Demonstrate proficient use of the microscope using low, high dry,
Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES
BIODIVERSITY I BIOL1051 Microscopy Professor Marc C. Lavoie [email protected] MAJOR FUNCTIONS OF MICROSCOPES MAGNIFY RESOLVE: => INCREASE CONTRAST Microscopy 1. Eyepieces 2. Diopter adjustment
OPERATING INSTRUCTIONS XJL 101/101A REFLECTED LIGHT METALLURGICAL MICROSCOPE
OPERATING INSTRUCTIONS XJL 0/0A REFLECTED LIGHT METALLURGICAL MICROSCOPE M.R.C.LTD. OFFICES: HAHYSTADRUT 84, HOLON 58394 P.O.B. 684, TEL-AVIV 606, ISRAEL TEL: 97-3-559305,97-3-55955 FAX: 97-3-559459 www.mrclab.com
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODELS 106, 106-L 107, 107-L 108, 108-L 109-L ELEMENTARY
Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012
Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012 Figure 1.1 illustrates the parts of an upright compound microscope and indicates the terminology that I use in these notes. Figure 1.1. Parts of a Compound
BIO 10 Lab 1 Introduction Pre Lab Test
BIO 10 Lab 1 Introduction Pre Lab Test 1. Why is the microscope in our lab called a compound microscope? 2. How do you calculate total magnification? 3. What is the lowest and the maximal magnification
HISTOLOGY LABORATORY. Microscope Orientation and Blood Smear Lab
HISTOLOGY LABORATORY Microscope Orientation and Blood Smear Lab For practicing how to use the microscope DO NOT use the blood smear slide (it is too boring for the lower mags). Use a slide from the white
Use of the Microscope and Cytology
Use of the Microscope and Cytology Introduction: A true study of anatomy not only considers the large, visible structures of an organism, but also the small structures that provide the organism its form
National Optical & Scientific Instrument Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instrument Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR STEREOSCOPIC MICROSCOPES MODEL NUMBERS 400 400TL
Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University
Chapter 4 Microscopy, Staining, and Classification 2012 Pearson Education Inc. Lecture prepared by Mindy Miller-Kittrell North Carolina State University Microscopy and Staining 2012 Pearson Education Inc.
MICROSCOPES & REFRACTOMETERS for laboratory, industry and food
Printed in Germany by & SOHN GmbH z-co-gb-kp-20152 Tradition and Innovation for 170 years An independent family business, since already 7 generations is synonymous with quality and reliability in customer
Microscopes and the Metric System
Microscopes and the Metric System BIO162 Fall 2007 Sizes of Microorganisms: -Viruses: 0.01 0.3 um -Bacteria: 1 3 um -Fungi: 3 30 um -Protozoa: 5 1000 um 1 Measuring Microorganisms Ocular Micrometer The
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODELS 130, 131, 132, 138 & 139 COMPOUND MICROSCOPES
ST-80 MICROSCOPE With Electronic Eyepiece #6810. User Guide
ST-80 MICROSCOPE With Electronic Eyepiece #6810 User Guide The ST-80 Microscope Thank you for purchasing your student microscope from ioptron. The ST-80 Microscope is both versatile and easy to use with
A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31
A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31 Phase contrast Relief contrast Incorporation of advanced UIS2 optics ensures the highest level of clarity for cell checking applications.
LAB 3 Use of the Microscope
LAB 3 Use of the Microscope Introduction In this laboratory you will be learning how to use one of the most important tools in biology the compound light microscope to view a variety of specimens. You
Microscopy and Cellular Morphology
Microscopy and Cellular Morphology As we discussed in class, many organisms on the planet exist as single cells and are referred to as microorganisms bacteria, protozoans, among others. When a single microorganism
euromex microscopen bv The Netherlands www.euromex.com page1/16
euromex microscopen bv The Netherlands www.euromex.com page1/16 Introduction The Oxion series has been designed with all kind of Life Sciences applications and great durability in mind. This resulted in
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODEL DC5-163 COMPOUND BIOLOGICAL MICROSCOPE WITH
ISO9001 ISO14001. Environmentally-friendly product All optical components in CX41 microscope use lead-free eco-glass.
Specifications Item Optical system Illumination CX41 UIS2 (Universal Infinity-corrected) optical system Built-in transmitted Koehler illuminator 6V30W halogen bulb 100-120V/220-240Vg 0.85/0.45A 50/60Hz
Protocol for Microscope Calibration
Protocol for Microscope Calibration A properly calibrated system is essential for successful and efficient software use. The following are step by step instructions on how to calibrate the hardware using
CALIBRATION FOR LAL20X & LAL24X
CALIBRATION AND FAULT FINDING FOR LAL20X & LAL24X DUMPY LEVELS MEASURING EXPERTS SINCE 1869 How The LAL20X & LAL24X Works The Automatic level is called Automatic because it requires only a simple basic
The illustrations below reflect other scientists results in identifying and counting the stages of the onion root tip and the whitefish blastula.
Abstract: The purpose of this laboratory experiment was to identify in what stage of mitosis viewed cells were in. The stages of mitosis include prophase, metaphase, anaphase and telophase. Although the
To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.
STAGE MICROMETERS Introduction Whenever there is a need to make measurements with an eyepiece graticule, there is also a need to ensure that the microscope is calibrated. The use of a stage micrometer
3.1 Cells and cell function
BTEC s own resources 3.1 Cells and cell function In this section: P1 How you are made Key terms Tissue a group of similar cells acting together to perform a particular function. Epithelial cells one of
VICKERS HARDNESS TESTER. HBS HBW Kc
ICKERS HARDNESS TESTER H HK HBS HBW Kc Clean Touch Panel coordinated with highly integrated PC board. Measuring procedures, conditions and data are displayed clearly. (F-800 Series) Accurate light load
Measuring. User Manual
0 1 2 3 4 5 6 7 8 9 10 11 Measuring User Manual Accessories for measuring tasks Stage micrometer (1) for calibration Graticules with various measuring pitches (2) in mm and inches Graticule with mesh (3)
GLobAL Dental Microscopes. Dentists First Choice
GLobAL Dental Microscopes Dentists First Choice Great prospects and an even better view There is something in every GLobAL dental microscope: Your high standard! That s why GLOBAL has only one priority:
How to make a Galileian Telescope
How to make a Galileian Telescope I. THE BASICS THE PRINCIPLES OF OPTICS A Galileian telescope uses just two lenses. The objective lens is convergent (plano-convex), the ocular lens is divergent (plano-concave).
Features: Mounting the Optic
MICRO GREEN DOT with INTEGRATED RED LASER The Patented Micro Green Dot with Integrated Red Laser is a compact optical system packed with many features. The Green Dot is designed as the primary targeting
Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.
Revision problem Chapter 18 problem 37 page 612 Suppose you point a pinhole camera at a 15m tall tree that is 75m away. 1 Optical Instruments Thin lens equation Refractive power Cameras The human eye Combining
MALARIA PARASITE COUNTING
VERSION 1 EFFECTIVE DATE: 01/01/2016 MALARIA PARASITE COUNTING MALARIA MICROSCOPY STANDARD OPERATING PROCEDURE MM-SOP-09 1. PURPOSE AND SCOPE To describe the procedure for counting malaria parasites on
OLYMPUS SYSTEM MICROSCOPE. Model BHT OLYMPUS
OLYMPUS SYSTEM MICROSCOPE Model BHT OLYMPUS This instruction manual has been written for the use of the Olympus System Microscope Model BHT. It is recommended that you read the manual carefully in order
A Fishy Tale. Observing the Circulatory System of a Goldfish with a Compound Light Microscope
A Fishy Tale Observing the Circulatory System of a Goldfish with a Compound Light Microscope A Fishy Tale About this Lesson In this lesson, students will explore a computer animation of the human body
The Applied Imaging Cytogenetic Workstation
The Applied Imaging Cytogenetic Workstation Introduction to the Genus F.I.S.H. Imaging System. The Genus Imaging System is a powerful and easy way to capture Fluorescence in-situ Hybridisation pictures
1. Examine the metric ruler. This ruler is 1 meter long. The distance between two of the lines with numbers on this ruler is 1 centimeter.
Nano Scale How small is small? It depends on your point of reference. A human is very small compared to the earth. A grain of salt is very small compared to a human. However, a grain of salt is very large
Photovoltaic Cell: Converting Light to Electricity
Photovoltaic Cell: Converting Light to Electricity Outcomes: 1. Understand that a photovoltaic cell produces DC voltage when light shines on its surface. 2. Understand that the electrical voltage produced
Animal & Plant Cell Slides
Animal & Plant Cell Slides Category: Biology Type: Class Experiment, 60 min class Materials: 2 Glass Slides 2 Cover Slips 1 Bottle of methylene blue (optional) 1 Plastic tray 1 Bottle of iodine 1 Plastic
Main Library Meeting Room Use
Main Library Meeting Room Use Occupancy: Meeting Room A: 100 Meeting Room B: 50 Meeting Room C: 50 Combined A, B & C: 300 Conference Room: 20 Tables: 50 (2x5 ), 4 (3 ), and 16 round (8 ) Chairs: 290 This
The How Do Guide to AxioVision. Author: Brian Svedberg Image Analysis Specialist Carl Zeiss MicroImaging, Inc.
The How Do Guide to AxioVision Author: Brian Svedberg Image Analysis Specialist Carl Zeiss MicroImaging, Inc. How do I grab a single image? How do I grab a single image? Click on the Camera icon to switch
User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up
2 Luxxor Video Microscope Set Up User Guide LUXXOR VIDEO MICROSCOPE Column When removed from its packaging, the Luxxor Video Microscope will be configured as shown, with the Vertical Slide and Slide Stop
VISM Evolution Scope Series
1 VISM Evolution Scope Series Congratulations on the purchase of your New VISM Evolution (EVO) Series Scope! The EVO Series of Scopes give you many great high end features and various magnification ranges
Review: Amscope Metallurgical Trinocular Microscope. Michael Reese Much FRMS EMS Bethlehem, Pennsylvania USA
Review: Amscope Metallurgical Trinocular Microscope Michael Reese Much FRMS EMS Bethlehem, Pennsylvania USA Amscope is an importer and distributor of microscopes and microscopy products and accessories
LABORATORY MICROSCOPEs
LABORATORY MICROSCOPEs 2011 OPTIKA LABORATORY MICROSCOPES B-350 SERIES - Entry-level upright laboratory microscopes page 5 B-500 SERIES - High quality upright laboratory microscopes page 13 B-600 SERIES-
COMPARING PLANT AND ANIMAL CELLS
COMPARING PLANT AND ANIMAL CELLS OBJECTIVES: Distinguish between plant and animals cells by their structures Demonstrate the benefit of stains Acquire ability to prepare wet mounts SAFETY: Methylene blue
MICROSCOPE & OPTICAL CATALOG
MICROSCOPE & OPTICAL CATALOG Kyowa Optical Co.,Ltd General Catalog Light source attachmentφ8 +0.1 0 27 C mount 35 C mount mounting screws φ30 20 C mount C mount mounting screws Depth 4-M4 6 (for installation)
RESEARCH MACRO ZOOM SYSTEM MICROSCOPE MVX10. Macro View. The first true macro fluorescence imaging system
The first true macro fluorescence imaging system RESEARCH MACRO ZOOM SYSTEM MICROSCOPE MVX10 Macro View The ultimate in macro fluorescence im The new MVX 10 MacroView from Oly Researchers are interested
Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments
Lecture 17. Image formation Ray tracing Calculation Lenses Convex Concave Mirrors Convex Concave Optical instruments Image formation Laws of refraction and reflection can be used to explain how lenses
Cells. Introduction WSBCTC 1
Cells Cells are the fundamental unit of life. All living things are composed of cells. While there are several characteristics that are common to all cells, such as the presence of a cell membrane, cytoplasm,
OLYMPUS STUDENT MICROSCOPES IINSTRUCTION MANUAL I CBA& CBB MODELS
OLYMPUS STUDENT MICROSCOPES IINSTRUCTION MANUAL I MODELS CBA& CBB Scanned by J. G. McHone. 8 Nov 09 for personal use only. not for sale This instruction manual has been prepared for the Olympus Student
Geometric Optics Converging Lenses and Mirrors Physics Lab IV
Objective Geometric Optics Converging Lenses and Mirrors Physics Lab IV In this set of lab exercises, the basic properties geometric optics concerning converging lenses and mirrors will be explored. The
Light and its effects
Light and its effects Light and the speed of light Shadows Shadow films Pinhole camera (1) Pinhole camera (2) Reflection of light Image in a plane mirror An image in a plane mirror is: (i) the same size
CX21 INSTRUCTIONS EDUCATION MICROSCOPE IVD
INSTRUCTIONS CX21 EDUCATION MICROSCOPE This instruction manual is for the Olympus Education Microscopes Model CX21. To ensure the safety, obtain optimum performance and to familiarize yourself fully with
PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24
PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24 V112712 1 Collimation and Secondary Spacing Procedure The CDK optical design has four optical elements shown in Figure 1. The primary mirror
Installation and use of Millett Tactical TRS-1 and TRS-2 scopes TRS-1 TRS-2. Before starting, make sure firearm is UNLOADED!!
I N S T R U C T I O N a n d O P E R A T I O N TRS-1 TRS-2 Tactical Rifle scope Installation and use of Millett Tactical TRS-1 and TRS-2 scopes TRS-1 TRS-2 Before starting, make sure firearm is UNLOADED!!
MENG 302L Lab 1: Hardness Testing
Introduction: A MENG 302L Lab 1: Hardness Testing Hardness Testing Hardness is measured in a variety of ways. The simplest is scratch testing, in which one material scratches or is scratched by another.
OBJECTIVES PROCEDURE. Lab 2- Bio 160. Name:
Lab 2- Bio 160 Name: Prokaryotic and Eukaryotic Cells OBJECTIVES To explore cell structure and morphology in prokaryotes and eukaryotes. To gain more experience using the microscope. To obtain a better
Comparing Plant and Animal Cells
1.2 Comparing Plant and Animal Cells Here is a summary of what you will learn in this section: Plant and animal cell structures are called organelles. Plant and animal cells perform some similar functions,
Leica DM300 User Manual
Leica DM300 User Manual Congratulations! Congratulations on purchasing the Leica DM300 Compound Microscope. This model s exclusive design features and full range of accessories make it a truly versatile,
Installation Instructions
Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply
Rauserv Steam Sterilizers, Laboratory and Hospital Equipment. Brewery Laboratory Equipment
Rauserv Steam Sterilizers, Laboratory and Hospital Equipment Brewery Laboratory Equipment Date: 01 September 2015 Table of Contents 1. Anaerobic Jar... 1 2. Autoclave... 2 3. Balance... 3 4. DO (Dissolved
OLYMPUS STUDENT MICROSCOPES INSTRUCTIONS ST. HS&HSC MODELS OLYMPUS
OLYMPUS STUDENT MICROSCOPES INSTRUCTIONS MODELS ST. HS&HSC OLYMPUS OLYMPUS MICROSCOPES MODELS ST, HS, HSB, HSC This booklet describes the common features and functions of Models ST, HS. HSB and HSC of
Leica DM500 & DM750. A New Generation s Choice of Innovative Educational Microscopes
Leica DM500 & DM750 A New Generation s Choice of Innovative Educational Microscopes 2 LEICA DM500 / DM750 INNOVATIVE EDUCATIONAL MICROSCOPES Made for Future Nobel Prize Winners Science Teaching Revitalized
Experiment #12: The Bohr Atom. Equipment: Spectroscope Hydrogen and Helium Gas Discharge Tubes, Holder, and Variac Flashlight
Experiment #12: The Bohr Atom Purpose: To observe the visible spectrum of hydrogen and helium and verify the Bohr model of the hydrogen atom. Equipment: Spectroscope Hydrogen and Helium Gas Discharge Tubes,
Solution Derivations for Capa #14
Solution Derivations for Capa #4 ) An image of the moon is focused onto a screen using a converging lens of focal length (f = 34.8 cm). The diameter of the moon is 3.48 0 6 m, and its mean distance from
VISM CQB Scope Series
1 VISM CQB Scope Series Congratulations on the purchase of your new VISM CQB Scope! The CQB Series of Scopes give you many great options so you can choose the scope that best fits your needs. Backed by
Atomic Force Microscope
Atomic Force Microscope (Veeco Nanoman) User Manual Basic Operation 4 th Edition Aug 2012 NR System Startup If the system is currently ON To start the NanoScope software, double-click the NanoScope startup
EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS
EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS The following website should be accessed before coming to class. Text reference: pp189-196 Optics Bench a) For convenience of discussion we assume that the light
2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.
Physics for Scientists and Engineers, 4e (Giancoli) Chapter 33 Lenses and Optical Instruments 33.1 Conceptual Questions 1) State how to draw the three rays for finding the image position due to a thin
FirstView 3 Reflector Telescope Owner s Manual
FirstView 3 Reflector Telescope Owner s Manual 1. Horizontal Locking Auxiliary Screw 2. Main Mount 3. Pitching Auxiliary Knob 4. Pitching Shaft Screw 5. Rack and Pinion Focusing Knob 6. Thumb Nut for Finder
Urinalysis and Body Fluids CRg
Urinalysis and Body Fluids CRg Unit 2; Session 1 Urine Microscopic Examination The Complete Urinalysis Physical properties already covered Chemical analysis in the next unit Microscopic our current focus
MACRO PHOTO LENS. MP-E 65mm f/2.8 1-5 ENG. Instruction
MACRO PHOTO LENS MP-E 65mm f/2.8 1-5 ENG Instruction Thank you for purchasing a Canon product. Canon Macro Photo Lens MP-E 65mm f/2.8 1-5 is a high-magnification macro lens that can magnify the subject
9/16 Optics 1 /11 GEOMETRIC OPTICS
9/6 Optics / GEOMETRIC OPTICS PURPOSE: To review the basics of geometric optics and to observe the function of some simple and compound optical devices. APPARATUS: Optical bench, lenses, mirror, target
LOUPES AND HEADLIGHTS HEADLIGHTS. HEINE Headlights. Type of Light LED LED F.O. Light Intensity (at 250 mm working distance)
HEADLIGHTS [ 111 ] HEINE Headlights LED MicroLight ML 4 LED HeadLight MD 1000 Headlight Technical Data Type of Light LED LED F.O. Light Intensity (at 250 mm working distance) Up to 40,000 Lux Up to 50,000
Basics to Using the View Camera
Walker Evans at work Using the View Camera Basics to Using the View Camera Because of the large-scale nature of the view camera, it is necessary to follow basic steps in setting-up the camera in order
Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03
Operator s Maintenance Manual STEINER BINOCULARS Military ruggedness and precision 07/03 W arning! When using the binocular, never point it directly at the sun. The heat generated by the focused rays of
Prokaryotic and Eukaryotic Cells
Lab 2- Bio 201 Prokaryotic and Eukaryotic Cells Name: OBJECTIVES To explore cell structure and morphology in prokaryotes and eukaryotes. To gain more experience using the microscope, and in particular,
M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual
M A R C O CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual CONTENTS GENERAL DESCRIPTION............... 1 INSTALLATION...................... 2 Mounting the Projector Positioning the Projector Positioning
CHAPTER 3 OBSERVING MICROORGANISMS THROUGH A MICROSCOPE. I. UNITS OF MEASUREMENT - See Table 3.1 in text. + Fig. 3.2
CHAPTER 3 OBSERVING MICROORGANISMS THROUGH A MICROSCOPE I. UNITS OF MEASUREMENT - See Table 3.1 in text. + Fig. 3.2 II. MICROSCOPY: THE INSTRUMENTS A. COMPOUND LIGHT MICROSCOPY Figure 3.3 1. Have ocular
First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between
Optical Differences Between Telescopes and Microscopes Robert R. Pavlis, Girard, Kansas USA icroscopes and telescopes are optical instruments that are designed to permit observation of objects and details
Biological Microscope. Biological Microscope ECLIPSE E200
Biological Microscope Biological Microscope ECLIPSE E200 Features exceptionally bright and uniform LED illumination and Nikon s high-quality optics. Ergonomic and anti-mold design ensures years of comfortable
PORTABLE PA SYSTEM #1 LAST UPDATED: FEBRUARY 2011
PORTABLE PA SYSTEM # LAST UPDATED: FEBRUARY 20 The portable PA system has been created to offer student groups an easy to use solution for self-operated sound needs. The system has the capability for:
Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!
Instructions Manual Flexia BGA Inspection Systems This manual describes how to use Flexia BGA Inspection System Optilia Instruments 1 AB Contents 1. Safety and maintenance Instructions 3 2. About Flexia
Institut für Experimentelle Immunologie und Bildgebung
Page 1 von 6 Starting Up the System Start up the computer, start Windows and log in as IMCES_user start BD FACSDiva software with your Groupname Turn on the cytometer main power Wait a moment and Check
GLOSSARY of STAINS Hematoxylin and Eosin (H&E) Periodic acid-schiff s (PAS) Masson s Trichrome Stain Gomori Trichrome Stain Silver Salts
GLOSSARY of STAINS Your study and comprehension of the slides in your collection will be enhanced if you know something about the staining methods used in their preparation. The following list includes
Microscopes 2014 Microscopes PB Microscopes 1
Microscopes 2014 Microscopes 1 Microscopes 2014 Microscopes 2 Just as Celestron s industry-leading telescopes reveal distant galaxies hidden in the night sky, our innovative microscopes give a new perspective
CALIBRATING YOUR SYSTEM. Follow our guidelines carefully to ensure proper system function. EQUIPMENT
Follow our guidelines carefully to ensure proper system function. EQUIPMENT A microscope system (camera, stage, objectives, computer etc.) Calibration grid slide The latest version of MBF software. Optional:
The upright transmitted microscope is most suited to our purpose of observing samples of compost, soil and compost tea, etc.
Microscope Advisory The following is based on my experience, my knowledge from studying and communicating with other microscopists. Others may have different opinions, experience and knowledge. First of
IMPORTANT. 2. Avoid the use of the microscope in direct sunlight, high temperature and humidity, dust and vibration.
MODEL BHS SYSTEM MICROSCOPE This instruction manual is for use of your instrument. Before putting it into operation, we recommend you read this manual carefully in order to familiarize yourself fully with