TENDER: Tf{/0006120151 A



Similar documents
Communication, Signal & Data Cables

Specification SFTP CAT6 Network Cable 23AWG CU

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

LS Data Communication Product

TECHNICAL SPECIFICATION

INTERNATIONAL STANDARD

Gulf Cable & Electrical Ind. Co.

E Series. E Series. Category 6 and 5e. Features

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

CAVEL VS80205 MADE IN ITALY 1000 V

Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof

WHITE PAPER December, 2001

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Data Communications Competence Center

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

Trunk Cables.

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

IT Cabling Solutions

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

Total Solutions Verification

APR 2016 Rev M

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Commercial Coaxial Cable

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

Specifying an IT Cabling System

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Disclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com.

coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

Uniprise Solutions COAX 101. White Paper.

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

AWG: Cat5e: Cat6: Cat6A:

db MISER ULTRA LOW LOSS CABLE ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget?

Open System Architecture

Network Engineers Everywhere:

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Coaxial Cables for Medium-Frequency Applications

OPTICAL FIBER CABLES

LOW LOSS CABLE PAG. 1

with Component Rating A Simple Perspective

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Global cable expertise for rolling stock

Standards Affecting a Premise T-1 Installation

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

Copper Cabling Infrastructure Offering

Always with Our Customers

Implementing Fast Ethernet

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

RADOX railway cables acc. to EN and EN Edition 2009

Cat 5, 6 or 7? Standards. Background. A University Standard for Structured Wiring. Network Points Installed. British Standards.

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

The High Cost of a Low-Cost Cable Certification Tester

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

Tri-Rated Flexible PVC Equipment Wire

Outside Telephone Cable

with coloured cores and overall copper screen UL/CSA... 17

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

COAX Cables Radio Frequency Cables

Panduit 28 AWG Patch Cords Installation Guideline

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

CCTV System Troubleshooting Guide

C 060 CCTV Coaxial Cable

Cabling for 10GBASE-T and Beyond - A Tangled Web

RF & Microwave cable assemblies C291

Power over Ethernet (PoE)

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications

Flexible and safe solutions, for decades. Cables for alarmand safety systems

Direct Attach Cable with Micro Coaxial Wire for Data Center

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

How to Choose the Right Cable Category

Accelerating Light. Copper Cabling Solutions. Category 6A

Comm5 Wiring Installation

Connecting Wireless. Distributed Antenna System Cable & Connectivity

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

Configuration RJ-45 (IEC ) 6-7. Categories and NEW terms EN , ISO/IEC De-embedded Re-embedded 14-15

B. PART 1 - GENERAL of SECTION BACKBONE COMMUNICATIONS CABLING shall also apply to this section.

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

Fibre Optic Indoor/Outdoor Cable

Data Cables. European Edition

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

Transcription:

/ %] *-@*telecom W* namibia TENDER: Tf{/0006120151 A The Supply and Delivery of Various optic fiber cables for the period of thre years For Telecom Namibia Tenderer name: { Total offer: N$. Page 1 of 19

rffi6%*telecom -ffi* n"rnribia PART B: SECTION 1 PRODUCT DESCRIPTIOI\S SPECIFICATIONS OR TERMS OF REFERENCE To assist Telecom Namibia in its seleetion of a suitable contractor, pre-set evaluation criteria have been identified and the under-mentioned points / marks have been allocated to the criteria as follows:-. Compliance to specifications 40 points. Price 35 points. BEE 15 points. Deliverv time 10 points TOTAL 100 COMPULS ORY REQUIREMENT : SHALL INVALIDATE THE YOUR OFFER.... SPECIFICATIONS ARE HEREWITH ATTACHED. Page 16 of 19

r Cat No. Description of Materials / Items 5706 Optic fiber overhead cable 12 core 5747 Ontic fiber overhead cable 24 core t. 5708 Ontic fiber overhead cable 48 core t 5970 Ootic fiber overhead cable 4 core ). 6L63 Optic fiber underground cable 4 core 6. 6164 Optic fiber underground cable 12 core 7 6165 Optic liber underground cable 24 eore 3. 6166 Ontic fiber underground cable 48 core Page 17 of 19

PART C: SECTION 1 Description of Materials / Items EDULE Optic fiber overhead cable 12 core Optic fiber overhead cable 24 core Optic fiber overhead cable 48 core Optic fiber overhead cable 4 core Optic fiber underground cable 4 core Optic fiber underground cable 12 core Optie fiber underground cable 24 core Optic fiber underground cable 48 core LOCAL VAT TRANSPORT TOTAL Page 18 of 19

%k"telecom TENDER: TN/0007/2A151A The Supply and Delivery of Of Cable Cat 5e screened and UV Resistant - 4pr for the period of three years (3) to Telecom Namibia Tenderer name:..... t Total offer: N$ Page 1 of17

%W.telecom namibia PART B: SECTION 1 PRODUCT DESCRIPTIONS Item 3at No. Estimated Annual usage Description of Materials / Items i82l 70 000m Cable Cat 5e screened and IfV Resistant - 4pr SPECIFICATIOI{S OR TERMS OF REFERENCE To assist Telecom Namibia in its selection of a suitable contractor, pre-set evaluation criteria have been identified and the under-mentioned points / marks have been allocated to the criteria as follows:-. Compliance to specifications 40 points t. Price 35 points r BEE 15 points. Delivery time 10 points TOTAL 100 Compulsory requirements: * Each tenderer must submit with their offer a sample of lm lenglh. Paee 76 of 17

-qffrif- PART C: SECTION 1 Description of Materials / Items Cable Cat 5e screened and UV LOCAL VAT GENERAL INSTRUCTIONS FOR COMPLETION OF'PRICE SCHEDULES 1. All prices to be indicated in Namibia Dollars. 2. All prices to be quoted as DDP or CIF, excluding VAT, Telecom Main Stores, Windhoek. 3. VAT shall be included on tlre Price Sumlnary sheet. (Local Suppliers only) 4. Tenderers shall add any other available additional features to the tender document or a Covering letter. 5. Clarifying comments on any item shall be submitted on a separate schedule, refening to the item number. Please quote this teader number in all future inquiries! Signature TN/0007/205/A Date Page17 of77

I ;,I l l %%telecom *#* namibia TEI{DER: TI{/00 ABD0LS O The Supply and Delivery of Cat 6 UTP Cables for a period of three (3) Years for Telecom Namibia Tenderer name: d Toial offer: N$ Page I of 24

W-telecsm PART B: SECTION 1 PRODUCT DESCRTPTIONS ltem Cat No. Descrintion of Materials / Items 8070 Cat 6 UTP Cables SPECIFICATIONS OR TERMS OF REFERENCE I To assist Telecom Namibia in its selection of a suitable contractor, pre-set evaluation criteria have been identified and the under-mentioned points / marks have been allocated to the criteria as follows:- {. Compliance to specifications 40 points r Price 35 points r BEE 15 points. Delivery time 10 points TOTAL 100 Page 16 of24

COMPULS ORY REQUIREMENT: {. NB: PLEASE SUBMIT WITH YOUR TEM)ER OFFER (1) METER LENGTH SAMPLE FOR EACH CABLE TYPE. FAILIJRE TO SUBMIT SAMPLES SHALL INVALIDATE TIIE YOUR OFFER. Page 17 of24

PART C: SECTION 1 Description of Materials / Items Cat 6 UTP Cables TRANSPORT TOTAL GENERT{L INSTRUCTIONS FOR COMPLETION OF PRICE SCHEDULES 1. All prices to be indicated in Namibia Dollars. Z. All prices to be quoted as DDP or CIF, excluding VAT, Telecom Main Stores, Windhoek. 3. VAT shall be included on the Price Summary sheet. (-ocal Suppliers only) 4. Tenderers shall add any other available additional features to the tender document or a Covering letter. 5. Clarifying comments on any item shall be submitted on a separate schedule, referring to the item number. Please quote this tender number in all future inquiries! Signature TN/0008/2015/O Date Page 18 of24

General Technical Snecifications Cat 6 UTP Cable Document Pro les Item. Details Document Title Author Ian Simwanza Simasiku Creation Date 23 Aus..l2 Last Updated 23 Jan. 13 Update Author Ian Simwanza Simasiku Change Log Version 1.8 Cat 6 UTP Cable Technical lpgglfigatiory-- Page 19 of24

GENERAL TECHMCAL SPECIFICATIONS : CAT 6 UTP CABLE TABLE OF'CONTENTS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Scope Cat 6 UTP Cable Technical Specifications...'... """""21 Test Samp1es... ""23 Materials Tests..23 Quality Assurance and Factory Testing. """""""" """'23 Packing """"23 Delivery " """ 24 Store Room """""""""24 Certification Training ""24 Quotations ""24 Warranty.. Page20 of24

1. Scope This document defines the requirements and technical specifications for the cat 6 UTP cable to be supplied to TelecomNamibia. 2. Cat 6 UTP Gable Technical Specifications a. The cable shall be suitable for indoor installation b. The cable electrical wires shall be made up of copper and shall be insulated c. The cable electrical wires shall be solid and flexible, and shall have a cylindrical shape d. The cable shall have four twisted wire pairs e. The cable twisted wire pairs shall have standard color codes f. The cable shall have a sheath around the four twisted wire pairs g. The cable shall provide performance of up to 250 MTIz and shall be suitable for I 3BASE-T, 1 Q0BASE-TX (Fast Ethernet) and I 000BASE-T/1 O00BASE-TX (Gigabit Ethernet) tl. l. The cable electrical wires shall have 100% tested wiring sequence continuity The cable insulated electrical wires shall be attached to the RI45 connectors without difficulties In addition to the specifications mentioned above, the cable shall comply with all specifications mentioned in table 1 on the next page Page2l of24

Tahlo 1' (]at A IITP Cable ificatlons Construction Conductor lnsulation Pairs Sheath Colour code Jacket 23 AWG or 24 Solld bare uopper (4 pair) H igh Denslly Iqlygllylele Thickness: 2 0.2 mm ffi 2 lnsulated conductors twsted toqether LSZH or CMR or HDPE Pair 1 : White/blue-blue P air 2: Wh ite/oran ge-oran ge Pair 3: White/green-green P air 4: White/brown-brown Color: Grey Thickness: 2 0.5 mm Diameter:: > 5.0 mm Mechanical P Bending Radius (mm) Bending Radius Static (mm) during installation E 30 wittrout load or 4 x OD after installation Operatinq Temperature Range ("C) _291s +75 a+^rr^a Tarnnerafr rrc-r"n,r",o"'t 0 to +80 \ Electrical ProPerties Characteristic I mpedance (O) 1 00i1 5 Capacitanqe Unbalance (PF/1 0q41) < 330 < 20.00 Conductor Resistance at 20"C (Q/100m) Nominal Velocity of Propagation (0/o) >62.1 Resistance Unbalance (%) s5 Dielectric Strength (kv/min) s1 Insulation Resistance (MO.km) > 5000 Mutual Capacitance (nf/1 00m) < 5.6 Transmission Gharacteristics Per 100m at 250 MHz Frequenc Return Loss (db) Attenuation (db/100m) t > 1t.3 lzea IJJT Page22 of24

Near-End Crosstalk (db) > 38.3 Power Sum-NEXT (db) > 36.3 Equal Level-FEXT (db) > 19.8 Power Sum-ELFEXT (db) > 16.8 ACR (db) > 5.5 Propaqation Delav (ns) < 536.3 Delav Skew (ns) s45 3. Test Samples The Tenderer shall submit as part of the tender test samples of five meter cable identical to the specifications mentioned in table 1 on page 4 attheit own cost. 4. Materials Tests The Tenderer shall submit as part of the tender in detail the proposed test methods and acceptance test procedures for approval by Telecom Namibia. 5. Quality Assurance and Factory Testing The Tenderer shall submit fulidetails of own Quality Assurance procedures, which shall ensure that the cable comply with internationally recognised standards mentioned in tabie 2 below and with other International recognised standards that might have been omitted in this document. The supplier shall specify the international standards adhered to and certification thereof shull b" provided to Telecom Namibia. A11 cables shall be tested during manufacture at the manufacturer's expense to ensure that the cables meet all specifications mentioned in table 1 on page 4. The supplier shall submit to Telecom Namibia, on or before the delivery of cables, detailed test reports for every delivered cable and for each production batch of cable, for attention: The Project Manager. Table 2: Internationa ised Standards International Recognised Standards American National Standards Institute ANSI Telecommunications Industry Association TIA Electronic Industries Alliance EIA Internatio n ai Or gantzati on for S tandardizatio n ISO International Electrotechnical Commission IEC European Telecommunications Standards Institute ETSI 6. Packing The cable shall be packed in lengths of 500m in easy pull boxes/reels. Page23 of24

I. Delivery The cable shall be offloaded at Telecom Namibia Main Store Southern Industry Windhoek and delivery cost shall be included in the bid. Tenderers shall strictly commit to planned delivery dates. Deliveries will be accepted from Monday through to Friday and no deliveries will be accepted on public holidays or weekends unless requested by Telecom Namibia. 8. Store Room The Tenderer shali have a store room locally in Namibia and shall reserve at least six rolls of cables at the store room for emergency purposes. 9. Gertification Training The Tenderer shall provide certification training to Telecom Namibia technicians. Each technician shaii go through hours of training and pass extensive written and hands-on testing. The certification training course shall be well-structured to ensure that the course meet basic industry standards and the certification training course shall include, but not limited to, recent most industry standard updates, hands-on installation techniques, review of cat 5, 5e and 6 cabling, residential standards and testing. The Tenderer shall provide an Associate Installer Certificate to Telecom Namibia. l0.quotations The Tenderer shall submit separate quotations as indicated below for considerations. a. Without additional marking. E.g. Only manufacture standard marking b. With additional marking. E.g. Telecom Namibia logo together With manufacture standard marking (optional) c. Without additional marking plus with Certification training (optional) d. With additional marking plus Certification training (optional) 1 1. Warranty i The cable shall carry a warranty, against poor design, manufacture erors and workmanship. The warranty period shall be stated in the commercial documents that accompany the bid. END OF SPECIFICATION Page24 of24